Académique Documents
Professionnel Documents
Culture Documents
Standby Model:P44E
ISO 9001:2000
SWT DIESEL GENERATOR SET
QUALITY STANDARDS
The SUPERWATT generator set compliance with all main
standards, such as ISO8528 GB/T2820-97), GB755
BS5000, VDE0530, ISO3046, IEC34-1, CSA22-2, AS1359,
ISO14001.
Rating Range
1500RPM 50Hz
Standby:
Prime:
110-480V 3P4W
kW
35.2
k VA
44
kW
k VA
32
40
WARRANTY
ALTERNATOR RATINGS
Alternator Model
1500rpm
Cont.H -125/40
380
400
415
440
190
200
208
220
220
230
240
254
Rating capacity(kVA)
40.0
42.5
40.0
35.0
28.0
Rating power(kW)
32.0
34.0
32.0
Power efficiency(%)
86.7
86.6
87.3
87.6
Input power(kW)
36.9
39.3
36.7
36.5
Standby.H -163/27
380
400
415
440
190
200
208
220
220
230
240
254
Rating capacity(kVA)
44.0
44.0
44.0
44.0
Rating power(kW)
35.2
35.2
35.2
35.2
Power efficiency(%)
86.4
86.3
87.1
88.1
Input power(kW)
40.7
40.8
40.4
40.0
RATINGS: All three-phase units are rated at 0.8 power factor. Standby ratings : Standby
ratings apply to installations served by a reliable utility source. The standby rating is for
this rating. Ratings are in according with ISO-3046/1,BS 5514 ,AS 2789 , and DIN 6271.
Prime Power Ratings: Prime power ratings apply to installations where utility power is
unavailable or unreliable. At varying load, the number of generator set operating hours
is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in
accordance with IS0-8528/1, overload capacity in accordance with ISO-3046/1,BS 5514,
AS 2789, and DIN 6271. For limited running time and base load ratings, consult the
factory. The generator set manufacturer reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever.
GENERAL GUIDELINES FOR DERATION: Altitude: Derate 2.0% per 300m(984 ft.)
elevation above 1000m(3279 ft.) up to a maximum elevation of 2450m(8000 ft.).More than
2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11
(20
) temperature above 40 (104
).
ALTERNATOR
Specification
Type
Exciter type
Voltage regulator
Voltage regulation
Insulation
Protection
Rated power factor
0.8
Double layer concentric
Two thirds
12
Winding leads
Maximum overspeed
2250 Rev/min
Self excited machines do not
sustain a short circuit current
Altitude
The 2/3 pitch design avoids excessive neutral currents. With the
2/3 pitch and carefully selected pole and tooth designs,
ensures very low waveform distortion.
1.5%
Class H
IP23
Stator winding
Winding pitch
Waveform distortion
1500RPM 50Hz
DIESEL ENGINE
Engine Electrical
Application Data
Volts(DC)
Engine Specifications
1500RPM 50Hz
Cylinder arrangement
4
Vertical in-line
Cycle
Four stroke
Induction system
Naturally aspirated
Compression ratio
Bore
16.0:1
100 mm (3.937 in)
Stroke
Cubic capacity
Direction of rotation
Max.Power at rated rpm
47.5KW
420 kg (956 lb)
0.8%
Fixed
Dry
6.35 m/s
600
Direct
Rotary type
Fuel atomiser
Injection pressure
Multi hole
22.3 MPa (220 atm)
Total system
Normal oil operation
Relief valve opens
Normal oil temperature
30kPa(4.35 lbf/in 2 )
1.8 m (6.0 ft)
3.0 m (9.8 ft)
Electronic / Mechanical
0.85 - 0.85
2.0 - 3.2
Sulphur Content
Cetane Number
0.03%-0.05%
40-48
Fuel consumption
7.54m 3/min
(1112 )
1500RPM
98.1litres/hr(172.6 UK pints)
Viscosity (mm /s @ 40 )
1500RPM 50Hz
Power rating %
Lubrication
Lubrication system
1500RPM 50Hz
1500RPM 50Hz
5 kPa
63.93mm(2.5 in)
Type of injection
Fuel specification
Density (kg/l @ 15
1500RPM 50Hz
Flow/hour
Pressure
Maximum fuel pump suction
Maximum pressure head.
Governor type
Exhaust
Exhaust System
12V
Fuel System
1, 3, 4, 2
55A
12/24V options
Fuel
Firing order
Negative
12/24V options
Ampere rating
Starter motor rated voltage(DC)
Battery voltage
Lovol
Manufacturer
Number of cylinders
1500RPM 50Hz
50Hz
110
100
75
50
12.6(22.2)
10.9(19.2)
8.6(15.1)
5.9(10.4)
Application Data
Cooling System
Radiator
1500RPM 50Hz
Face area
Rows and materials
0.31 m 2 (3.33 ft 2)
3 rows, brass
12 copper
Width of matrix
Height of matrix
Fan
1500RPM 50Hz
Diameter
Drive ratio
Number of blades
Material
Coolant
1500RPM 50Hz
(158 )
( 13.8 )
Protection:
35 kPa( 5 lbf/in )
2
CONTROLLERS
Panel introduction:
Indicator or digital type frequency, voltmeter and ampere meter
demonstration unit's electrical parameter.
The big red button uses for the operator to stop the genset
peremptorily.
The controller.
Panel introduction:
Indicator type frequency, voltmeter and ampere meter
demonstration unit's electrical parameter.
The voltage change-over switch and the rheotrope uses for to
choose the different phase voltage and current to display.
The big red button uses for the operator to stop the genset
peremptorily.
The oil pressure gauge, coolant temperature gauge and the
battery voltage gauge.
The controller. And an integral anti-tamper LCD hours run
counter is also provided.
If the customer needs to use the preheating function, we will be
able to increase the preheating button.
Protection:
Low Oil Pressure
High Engine Temperature
Auxiliary Shutdown
Over speed
Function:
Communication: RS232 connection, uses the industry rank
MODBUS protocol can easily communicate with others
intelligence control system.
Display function: LCD screen can display the generator's
parameter and the control system's running information.
Set up parameter: Engineer can set up the controller parameter
from the control panel or through the PC, 6 programmable
fan-out may satisfy the user each kind of demand.
Protection: The control system can protect the generator set ,
manage each kind of electrical failure.
Control Function of ATS.
DC Supply: 8 to 35 V Continuous.
DC Supply: 8 to 35 V Continuous.
3
Paralleling System
Controller System
Accessories
Enclosed Unit
Miscellaneous Accessories
Sound Enclosure
Weather Enclosure (with enclosed critical silencer)
Weather Housing (with roof-mounted critical silencer)
Trailer(Causes the genset easily to move)
Open Unit
Exhaust Silencer, Critical kit
Open Style
Cooling System
Overall Size, L W H
Block Heater
(recommended for ambient temperatures below 0 )
mm
2200 730
Weight(radiator model),net,Kg
1700
935
Fuel System
Auxiliary Fuel Pump
Soundproof Style
Overall Size, L W H
Weight(radiator model),net,Kg
mm
2330 1110
1830
1140
Electrical System
Battery Charger, Equalize/Float Type
NOTE :
This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.
DISTRIBUTED BY: