Product Data Sheet

Version 6 (09 / 2015)

Sikasil SG-500
High performance structural silicone adhesive
Typical Product Data
Component A
Component B

Sikasil SG-500 A
Sikasil SG-500 B
2-C silicone
White / Light grey
Black / Dark grey
Black / Grey S6
(special colors are available on request)
Polycondensation
Neutral
1.4 kg/l
1.1 kg/l
1.37 kg/l

Properties
Chemical base
1

Color (CQP 001-1)


Color mixed
Cure mechanism
Cure type
Density (CQP 006-4)
Density mixed
Mixing ratio

A:B by volume
A:B by weight

10:1
13:1

Viscosity (CQP 029-5)


1100 Pas
300 Pas
Consistency
Paste
Application temperature
5 40 C
2
Snap time (CQP 554-1)
50 minutes
2
Tack-free time (CQP 019-1)
240 minutes
Shore A-hardness (CQP 023-1 / ISO 868)
45
Tensile strength (CQP 036-1 / ISO 37)
2.2 MPa
Elongation at break (CQP 036-1 / ISO 37)
300 %
Tear propagation resistance (CQP 045-1 / ISO 34)
6.0 N/mm
100 % modulus (CQP 036-1 / ISO 37)
1.1 MPa
12.5 % modulus (CQP 036-1 / ISO 37)
0.3 MPa
Movement accommodation capability (ASTM C 719)
12.5 %
2
Water vapor permeability (EN 1279-4)
19 g H2O / m 24 h2 mm
Thermal resistance (CQP 513-1)
180 C
Short term
4 hours
200 C
1 hour
220 C
Service temperature
-40 150 C
Shelf life (storage below 25 C) (CQP 016-1)
15 months
12 months
CQP = Corporate Quality Procedure

Description

Sikasil SG-500 is a two-part, highmodulus, neutral-curing structural


silicone adhesive.

2)

23C / 50% r.h.

Product Benefits
- Meets requirements of EOTA
ETAG 002, EN 13022 and ASTM
C 1184
- SNJF-VEC / VI-VEC recognized
- Fire rated (EN 11925-2 / DIN
4102-B1)
- Resistant to UV and weathering
- Provided with CE-mark according
to ETAG 002, DoP 01 27 03 01
003 9 001000 1024, certified by
Factory Production Control Body,
0757, certificate Nr. 0757-CPD596-04-001 R1e, 2009-05-25

Areas of Application

Sikasil SG-500 is ideal for structural glazing, bonding of solar


modules
and
other
highdemanding industrial applications.
This product is suitable for professional experienced users only.
Tests with actual substrates and
conditions have to be performed to
ensure adhesion and material
compatibility.

Sikasil SG-500 1 / 2

1)

Cure Mechanism

Sikasil SG-500 starts to cure


immediately after mixing the two
components.
The speed of the reaction depends
mainly on the temperature, i.e. the
higher the temperature the faster
the curing process. Heating above
50 C is not advisable as it may
lead to bubble formation.
The mixer open time, i. e. the time
the material can remain in the
mixer without flushing or extrusion
of product is significantly shorter
than the snap time indicated
above. For more information contact the Technical Department of
Sika Industry.
Application Limits

Most Sikasil WS, FS, SG, IG, WT,


AS and other engineering silicone
sealants manufactured by Sika are
compatible with each other and

with SikaGlaze IG sealants. For


specific
information
regarding
compatibility
between
various

Sikasil and SikaGlaze products


contact the Technical Department
of Sika Industry. All other sealants
have to be approved by Sika before using them in combination

with Sikasil SG-500. Where two


or more different reactive sealants
are used, allow the first to cure
completely before applying the
next.

Sikasil SG, IG and WT sealants


and adhesives may only be used in
structural glazing or window bonding applications by experienced
professionals and after a detailed
examination and written approval
of the corresponding project details
by the Technical Department of
Sika Industry.
The compatibility of gaskets, backer rods, setting blocks and other
accessory
materials
with

Sikasil SG-500 must be tested in


advance.
The above information is offered
for general guidance only. Advice
on specific applications will be
given on request.

Method of Application
Surface preparation
Surfaces must be clean, dry and
free from oil, grease and dust.
Advice on specific applications and
surface pre-treatment methods is
available from the Technical Department of Sika Industry.

Further Information
Copies of the following publications
are available on request:
- Safety Data Sheets
- General Guidelines Structural

Silicone Glazing with Sikasil


Adhesives

Application

Before processing Sikasil SG-500


both components have to be mixed
homogeneously and air-bubblefree in the correct ratio as indicated
with an accuracy of 10 %. Most
commercially available metering
and mixing equipment are suitable.
Contact the System Engineering of
Sika Industry for specific advice.

While the A-part of Sikasil SG-500


is stable in air, the B-part is moisture-sensitive and must only be
exposed briefly to air.
Joints must be properly dimensioned as changes are no longer
possible after construction. Basis
for calculation of the necessary
joint dimensions are the technical
values of the adhesive and the
adjacent building materials, the
exposure of the building elements,
their construction and size as well
as external loads. For more information contact the Technical Department of Sika Industry.

Packaging Information
Side by side cartridge
(comp. A + B)
Pail (comp. A)
Drum (comp. A)
Pail (comp. B)

Tooling and finishing


Tooling and finishing must be
carried out within the snap time of
the adhesive. No tooling agents
must be used.
Removal

Uncured Sikasil SG-500 may be


removed from tools and equipment

with Sika Remover-208 or another suitable solvent. The static


mixer of the metering and mixing
equipment can be cleaned with

Sika Mixer Cleaner.


Hands and exposed skin should be

washed immediately using Sika


Handclean towels or a suitable
industrial hand cleaner and water.
Do not use solvents!
Overpainting

Sikasil SG-500 is an elastic adhesive and cannot be overpainted.

490 ml
26 kg
260 kg
20 kg

Basis of Product Data


All technical data stated in this
Product Data Sheet are based on
laboratory tests. Actual measured
data may vary due to circumstances beyond our control.
Health and Safety Information
For information and advice regarding transportation, handling,
storage and disposal of chemical
products, users shall refer to the
actual Safety Data Sheets containing physical, ecological, toxicological and other safety-related data.
Disclaimer
The information, and, in particular, the
recommendations relating to the application and end-use of Sika products,
are given in good faith based on Sika's
current knowledge and experience of
the products when properly stored,
handled and applied under normal
conditions in accordance with Sika's
recommendations. In practice, the
differences in materials, substrates and
actual site conditions are such that no
warranty in respect of merchantability
or of fitness for a particular purpose,
nor any liability arising out of any legal
relationship whatsoever, can be inferred either from this information, or
from any written recommendations, or
from any other advice offered. The user
of the product must test the products
suitability for the intended application
and purpose. Sika reserves the right to
change the properties of its products.
The proprietary rights of third parties
must be observed. All orders are accepted subject to our current terms of
sale and delivery. Users must always
refer to the most recent issue of the
local Product Data Sheet for the product concerned, copies of which will be
supplied on request.

Sika Schweiz AG