Académique Documents
Professionnel Documents
Culture Documents
E-mailsales@tpy.cn
Method 2:
Put the screw through the earth terminal and
the sensor`s installation hole. Then fasten
the screw in the surface of the cabinet.
Humidity controller
Zip Code213022
Http//www.tpy.cn
5.
6.
7.
Temperature indicators-201001
Humidity indicators20%RH99%RH5%RH
Heating start-up conditionsTemperature display valueTemperature low
limits or Humidity display valueWet and heat setting value
Heating exit conditions: Temperature display valueTemperature low
limits+10 and Humidity display value Wet and heat setting value10%RH;when the temperature is higher than 50,stop heating
Output contacts : Two pairs load output AC220V/3A (It can work with
heater or Ac fan)
Work environment : Temperature: -1050; Humidity : <95%RH
Power supplyAC100V~AC250V/60HZ/50HZ
Power consumption10VA
8. Serial communication
Interface standardsRS485half-duplex
The largest network255
Communication rate4800 bit/s
Distance1000m
9. Dimension9696113 mm
10. Hole size9292 mm
11. Sensor: Temperature sensorLinear humidity sensorUsually, they
are installed together. But,according to the customen needs,they can
installed separately.
12. Sensor dimension : 755518mm Cable length: 2.5m(It can be chosen
by users)
5.
6.
7.
8.
Instructions
1.
2.
3.
4.
Fixed instrument and Wired according to the wiring diagram, Powerconfirmation, After self-diagnosis display "8", the LED displays
Temperature and humidity. If the temperature and humidity sensor
connection is error, it display "---".
Set the temperature and humidity sensor 1 temperature Lower limit value
t1L. Press and hold the SET button for 2 seconds to enter the set t1L state,
all bright lights, then the humidity line display t1L can set the temperature
Lower limit. Press or to change the lower limit, to achieve the
required values. (Temperature limit setting range is-2050)
Set the temperature and humidity sensor 2 temperature Lower limit value
t2L. After setting t1L, press the SET button to enter the set t2L state, then
the temperature line display t2L ,press or to change the lower limit.
(Temperature lower limit setting range is -2050)
Set the temperature and humidity sensor 1 humidity upper limit value H-1.
After setting t2L, press the SET button to enter the set H-1 state, then the
humidity line display H-1, press or to change the humidity setting.
9.
Panel Diagram
NoteUsers can make special requirements on the length of the sensor cable or control mode in
advance, in order to change the design in accordance with them.