Académique Documents
Professionnel Documents
Culture Documents
Date:
Authorized Inspector:
Date:
2. Manufactured for
Not known
3. Location of installation
Horizontal
4. Type
KG 150601-02
NA
KG 150601-01 Rev.01
2015
(CRN)
(Drawing number)
(Year built)
2013
None
None
Items 611 incl. to be completed for single wall vessels, jackets of jacketed vessels, shell of heat exchangers, or chamber of multichamber vessels.
6. Shell:
One
2935.0mm
Material
Thickness
Heat Treatment
No.
Diameter
Length
Spec./Grade or Type
Nom.
Corr.
Type
Full, Spot,
None
Eff.
Type
Full, Spot,
None
Eff.
Temp.
Time
355.6 OD
2935.0mm
SA 106 Gr.B
12.7mm
3.0
Full
1.0
Full
NA
NA
Type
ID
WNRF
330.2m
7. Heads: (a)
OD
Material
How Attached
(b)
Thickness
Location (Top,
Bottom, Ends)
Min.
Radius
Corr.
Crown
Knuckle
Elliptical
Ratio
Location
Conical
Apex Angle
Washer
(OD, ID, thk)
Bolting Material
Washer Material
Hemis.
Radius
Flat
Diameter
Side to Pressure
Convex
Category A
Concave
Type
Full, Spot,
None
Eff.
(a)
(b)
Location
ID
OD
Material
How Attached
Bolting Material
Washer
(OD, ID, thk)
Washer Material
(a)
(b)
8. Type of jacket
Jacket closure
(Internal)
at max. temp.
(Internal)
(External)
at
.
.
at test temperature of
Proof test
13. Tubes
(04/14)
(Diameter)
(O.D.)
(Nominal thickness)
(Nominal thickness)
(Nominal thickness)
(Corr. allow.)
(Corr. allow.)
(Number)
Date:
Authorized Inspector:
Date:
Course(s)
No.
Material
Diameter
Length
Thickness
Spec./Grade or Type
Nom.
Corr.
Full, Spot,
None
Type
Eff.
Full, Spot,
None
Type
Eff.
Heat Treatment
Temp.
Time
Type
ID
OD
Material
Thickness
Min.
Radius
Corr.
Crown
Knuckle
Elliptical
Ratio
(b)
Location (Top,
Bottom, Ends)
Location
How Attached
Conical
Apex Angle
Washer
(OD, ID, thk)
Bolting Material
Washer Material
Hemis.
Radius
Side to Pressure
Flat
Diameter
Convex
Category A
Concave
Type
Full, Spot,
None
Eff.
(a)
(b)
Location
ID
OD
How Attached
Material
Bolting Material
Washer
(OD, ID, thk)
Washer Material
(a)
(b)
16. MAWP
(Internal)
(External)
at max. temp.
(Internal)
No.
Diameter
or Size
(Yes or no)
Lugs
(Number)
.
.
Proof test
Material
Type
at
at test temperature of
(External)
Nozzle
Legs
(Number)
Nozzle Thickness
Flange
Others
Nom.
Corr.
Reinforcement
Material
(Describe)
Attached
Attachment Details
Nozzle
Flange
Location
(Insp. Open.)
21. Manufacturers Partial Data Reports properly identified and signed by Commissioned Inspectors have been furnished for the following items of
the report (list the name of part, item number, Manufacturers name, and identifying number):
22. Remarks
(04/14)
Date:
Authorized Inspector:
Date:
Expires
Name
Signed
(Manufacturer)
(Representative)
, and
state that, to the best of my knowledge and belief, the Manufacturer has constructed this pressure vessel in accordance with ASME BOILER AND
PRESSURE VESSEL CODE, Section VIII, Division 1. By signing this certificate neither the Inspector nor his/her employer makes any warranty, expressed
or implied, concerning the pressure vessel described in this Manufacturer's Data Report. Furthermore, neither the Inspector nor his/her employer shall
be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date
Signed
(Authorized Inspector)
Commissions
Name
(Assembler)
Signed
Expires
(Representative)
, have compared the statements in this Manufacturers Data Report with the described pressure vessel
inspected by me and to the best of my knowledge and belief, the Manufacturer has constructed and assembled this pressure vessel in accordance
with the ASME BOILER AND PRESSURE VESSEL CODE, Section VIII, Division 1. The described vessel was inspected and subjected to a hydrostatic test of
. By signing this certificate neither the Inspector nor his/her employer makes any warranty, expressed or
implied, concerning the pressure vessel described in this Manufacturer's Data Report. Furthermore, neither the Inspector nor his/her employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date
(04/14)
Signed
(Authorized Inspector)
Commissions