Vous êtes sur la page 1sur 24

Company Prole

1
HC Barcol-Air
Changes w/o notice or obligation.

Preface
True-out this company prole we hope to give you a good
impression of our company and products.

Thanking you in advance for taking the time to read our


company prole and your interest in our products.
We hope to be of any assistance to you in the nearby
future.
If you have any questions regarding our products please
do not hesitate to contact us.
Kind regards,

Lars Wiersma
Export Manager

2
HC Barcol-Air
Changes w/o notice or obligation.

Table of content
Subject

Page

Preface

Table of content

Company introduction
Mission statement
Facts & gures

4
4

Company vision

Introduction HC Groep

Prole

Climate laboratory, Product development & Acoustic reverberation room

8 - 10

Product overview

11 - 14

Induction VAV, the optimum indoor climate & energy efcient system

15

Combined knowledge VAV & Controls

16

References

17 - 21

Distributor list

22 - 23

HC Barcol-Air continuously aspires to further optimise the construction and the quality of all products. HC Barcol-Air preserve themselves the right
to carry out modications in product specications without notice or obligation.
S.E. & O.
Copyright Barcol-Air B.V. 2008
Nothing from this publication may be multiplied and/or made public by means of printing, photocopy, microlm or in whatever manner, without
preceding written authorisation of HC Barcol-Air.

3
HC Barcol-Air
Changes w/o notice or obligation.

Company introduction

Mission statement

Facts & Figures

HC Barcol-air is specialized in designing, developing and


realizing a perfect thermal indoor climate. All in compliance with the demands of the client, consultant and
architect. For small and large projects, in standard and
specic circumstances, from single products to complete
installations, including design and climate laboratory test
according to ISO standards.

It is HC Barcol-Airs goal to create an indoor climate,


which offers an optimum in terms of comfort. Always and
everywhere with a minimum of energy use.

Turnover HC Groep > 40 million euro and


> 150 employees
2 products groups Air distribution & Controls
> 60 employees
> 70 years experience in indoor climate / thermal
comfort
Combined knowledge of Air distribution & Controls
Added value by technical know-how
R&D departments, 6 engineers with 100 years combined experience
Full scale climate room, > 250 tests
Specials, > 2.500 special developed products
> 200 large BMS projects
> 10.000 Air Distribution projects
Projects in > 50 countries with 35 distributors

4
HC Barcol-Air
Changes w/o notice or obligation.

Company vision

Introduction

History

Designing and developing products and systems to create and control the environment in commercial buildings
using the minimum energy and providing with optimal
comfort.

The origin dates back to 1932, when Barber Colman started de develop Air Distribution, products and controls.

HC Barcol-Air is a domestic market leader with good


international presence who sets trends trough technical
knowledge and excellent broad product offering.

1900

BARBER-COLMAN Company (USA)

1935

Air Distribution Products Division

The name HC Barcol-Air must be synonym for thermal


comfort and quality.

1982

BARCOL-AIR (100% subsidiary of


Barber-Colman)

1987

Barber-Colman purchased by SIEBE Plc

1998

SIEBE + BTR = Invensys

Responsibility
e
n
O
,
e
c
r
u
o
S
One

The One Source, One Responsibility concept combines


a substantial product & system portfolio, know-how, service and experience to one efcient centre of excellence.
All components are designed to form complete integrated
systems, which guarantee perfect operating and performing HVAC installations.

Timeline:

Specialist in Air distribution products


HC Barcol-Air is manufacturer and supplier of a complete range of high quality Barber Colman air distribution
products and systems which can be supplied with a short
delivery time mainly from stock. Together with a range of
standard products HC Barcol-Air has all facilities (R&D
department & climate laboratory) to develop, test and manufacture specic products and systems and to provide a
total and best comfort solution.
Extensive know-how and cooperation with other company
product groups (controls, chilled ceiling and service) results in the best possible solution for every HVAC application, with project specic designs if needed. HC BarcolAir likes to implicate all its know-how and experience in
the early stage of the project, to be able to act as partner
in designing the best possible installation.
Clients, consultants and contractors can count on the
technical support of our sales engineers, supported by
our R&D team and climate laboratory facilities.

Current Situation
On April 1st , 2006 Barcol-Air B.V. was taken over by the
HC Groep, a market leader in the Netherlands, who can
offer a total comfort solution including design, testing and
commissioning.

5
HC Barcol-Air
Changes w/o notice or obligation.

Introduction HC Groep

Integral supplier

Combined strength

Comfort, safety and an optimal living- and working


environment the main goals for the HC Groep as an
integral supplier. Either climate ceilings, ventilation, air
treatment- or climate control, you will nd the perfect
solution within the HC Groep.

The companies united, the excellent service and the


nancially strong HC Groeps accommodated attendance, result in a powerful unit.

Versatile, high quality standards, exible and customerminded. Because of these high standards, consultants,
architects and contractors have been calling upon the
companies within the HC Groep.

Unity in diversity
The HC Groep consist of seven companies, each of them
fully aware of the latest market requirements and in direct
contact with business related partners.
The following overview pictures the different companies:

A unity, which pays close attention to the wishes and


needs of the business. By operating united, the companies can combine their services like never done before,
offering you only the best of the business on a daily
basis.
The HC Groep combines decades of knowledge and
experience. We are eager to share this knowledge with
you. On top of this, we have our own climate room, in
which full scale mock-ups can be constructed. A great
deal of difculties, which can occur during construction
and/or commissioning, can be prevented by performing
climate room tests. The quality of products supplied by
the HC Groep are guaranteed by a wide range of certications and attests of independent testing authorities.
Thus consolidating the reliability of the products.

Chillers / WP

Air handling units

Car parking ventilation

Air curtains
Roof fans
CCU / Dry coolers
Ventilation concepts

9 series
Own coils
TB1/T1
Eurovent certied

Ventilation systems
CO detection
Fire detection
Switchboard

Assembly & Metal


treatment

Climate ceilings

Car parking ventilation

Air Distribution & Controls

Metal ceilings
Industrial ceilings
Plaster ceilings
Air climate ceilings

Ventilation systems
CO/LPG detection
Fire detection
Switchboard

Grilles & Diffusers


CAV & VAV Units
Measuring and control stations
Building Management Systems

6
HC Barcol-Air
Changes w/o notice or obligation.

Prole

Organization
HC Barcol-Air consist of two main divisions: Air Distribution and Controls
Air Distribution Product:

Development

Production

Sales ( domestic & export)

Support
Controls products/BMS:

Engineering

Supply and Installalation

Wiring and panels

Software & Commissioning


Both are supported by the service department:

Call-out service

Service contracts

Refurbishment & up-grades

Judgment thermal comfort

End of Warranty

HC Barcol- Air Organization Chart

Organization
Management
Financial Administration

Marketing
R&D

Climate room

Air Distribution
Development
Production
Sales Domestic
Export
Support

Controls

Internal Operations

Domestic Sales
Project management
Supply & Installation
Wiring & Panels
Software & Commissioning
Service & support
Call-out
Contracts
Refurbishment Upgrades
End of Warranty

Order handling
Procurement
Logistics
Production
Warehouse
Quality

7
HC Barcol-Air
Changes w/o notice or obligation.

Climate laboratory & Product development

Introduction

Measuring robot

Recently,HC Barcol-Air has built a reverberation room


for sound testing of products and systems. This enables
Barcol-Air to test products and systems in the sphere of
thermal indoor climate and sound production and absorption.

The most important part of the measuring system, in


the actual size built mock-up, is the automatic moving
measuring robot with accurate air temperature and velocity sensors. The height of the measuring sensors is according NEN-ISO standards 0,1 0,6 1,1 and 1,7 meter
above the oor. These heights represent ankles, bottom,
trunk and head of the human body. The robot measures
the area from oor to ceiling and from front to back of the
test room.
Extra sensors are mounted on the robot on other heights
and in different measuring areas to detect possible irregularities (for instance asymmetry) of the air pattern.
Extra sensors are also mounted 5 cm below the ceiling to
check the air pattern of the supply diffusers.

Climate laboratory
The purpose of a full-scale climate laboratory test is to
give the principal, designer and consultant maximum
security about the installations design, in an early stage.
Especially when the design is completely new, not often
used or when the building has specic characteristics,
a climate laboratory test can prevent a lot of problems during construction or even after commissioning.
HC Barcol-Airs climate room in Purmerend (Netherlands)
has a maximum oor space of approx. 8 x 8 meter with
exible positional walls and ceiling up to a height of 3.3
meter . To perform full-scale tests, the room is built with
exact (actual) dimensions. The climate faade simulates
the outdoor conditions and can be cooled to simulate winter conditions and heated to simulate summer conditions.
Uniquely this test room has two climate facades from
bottom to ceiling, which enables to test also (complicated) corner rooms.
Mock-ups are not only built with actual dimensions but
also faade, ceiling, furniture, oor covering, convectors
and lightning can be built according to project specication. There is also the possibility of building special
application rooms like hospital rooms, dealing rooms,
laboratories and so on.

Fixed sensors
Besides the sensors on the measuring robot, there are
also sensors mounted on xed places for primary air temperature, supply air temperature, air volume, reference
room temperature, windowpane surface temperature (inand outside) and surrounding temperature.

Accuracy air velocity and temperature


sensors
The accuracy and response time of all sensors apply to
the standards set in the ISO 7726 (1998). The temperature sensors have a relative accuracy of 0,1 C and
a time constant of 2,3 second. The air velocity sensors
have an accuracy of 0,014 m/s and a time constant of
0,03 second.

In the climate laboratory of HC Barcol-Air static tests are


performed. This means that thermal conditions in- and
outside the mock-up are equally; there is no transmission
loss via walls, oor or ceiling.

Data Acquisition System


All measuring data is collected and processed with a,
by labVIEW supported, automatic Data Acquisition
System. labVIEW is a software program of National
Instruments for virtual instrumentation.

8
HC Barcol-Air
Changes w/o notice or obligation.

Climate laboratory & Product development

Standards

Reporting

The climate laboratory meets the most recent standards


NEN-ISO 7726 and NEN-ISO 7730. The results of
measurements and check of the air stream pattern and
distribution is generally checked against DIN 1946, part
2. The calculated comfort parameters are checked
against NEN-ISO 7730. It is also possible to check the
climate laboratory test results and comfort parameters
according to specic project demands.

After the climate laboratory test has been nished and


discussed with the principal, a complete and nal report
is made. This report describes in detail under which
conditions and how the test has been performed. The
measuring results and conclusion are a written proof of
the performance of the tested installation concept. By
recording accurately all data and results, the test can be
reproduced. Product development besides testing project specic installation concepts, the climate laboratory
is used for product and system research and development. One of HC Barcol-Airs main competences is
project specic design of air distribution components or
modication of standard products. These new product
can be tested easily to check whether they apply to the
set standards.

Presentation test results


Air temperature and velocity measuring results are presented in both graphical and table format. The data
acquisition system has a unique calculation module to
present real time not only air temperature and velocity but
also the PMV (Predicted Mean Vote), PPD (Percentage
People Dissatised) and DR (Draft Rate). All displayed
values are average values per 100 seconds.
The purpose of a full-scale climate laboratory test is to
give the principal, designer and consultant maximum
security about the installations design, in an early stage.
Especially when the design is completely new and not
used before.

9
HC Barcol-Air
Changes w/o notice or obligation.

Acoustic reverberation room

Introduction
HC Barcol-Air has built a reverberation room for predesign sound testing of products and systems. This enables Barcol-Air to test products and systems for thermal
indoor climate as well as sound production and absorption.

Acoustic performance
The test at HC Barcol-Air is executed in a reverberation
room (not certied), which has a volume of 65 m and a
reverberation time of 2.2 - 2.5 seconds.
Measurements are being executed through a calibrated
sound meter fabricated by Delta Ohm type HD2010,
which can determine the reverberation time for each
room/test set-up individually.

Measurement of inlet sound


The CAV/FCU will be set-up inside the reverberation
room with the outlet connected to the opening towards
the adjacent small room. This way a combination of
the inlet sound together with the radiated sound will be
measured.

Measurement of outlet sound


In this case the CAV/FCU will be placed in the small
adjacent room with the outlet connected towards the
reverberation room. Only discharge sound levels will be
measured in this case.

Reverberation room

H=2,70m

600

Acoustic calculations
The measured sound levels will be corrected with the
background noise and the reverberation time of the room,
which will also be measured both individually.
The measured sound power levels for the mid ranges
of frequency band 125 8,000 Hz and NR levels will be
presented in table and graph form.

399
Opening in wall
max. 110x150cm
(BxH)

200
432
H=2,90m

10
HC Barcol-Air
Changes w/o notice or obligation.

Product overview

VAV units
Type NA/NB

Round single duct VAV terminal

Pressure independent
For individual room temperature control
Model 100 to 400
Single or double wall construction
Compact
Low leakage damper
High accurate airow sensor
Quiet in operation

Type NK/NL

Rectangular single duct VAV terminal

Pressure independent
For individual room temperature control
Size 200x150 to 2000x1000mm
Single or double wall construction
350 mm installation length
Low leakage damper
High accurate airow sensor
Quiet in operation
VAV terminal with integrated soundattenuator
Pressure independent
For low noise requirements in high pressure or
high velocity systems
Model 100 to 400
Compact in size
Low leakage damper
High accurate airow sensor
Very quiet in operation

Type NS

Induction VAV terminal

Type NV

Pressure independent
For comfortable air distribution in systems with
high load variation
Model 100 to 400
Low leakage damper
High accurate airow sensor
Very quiet in operation
Provides savings in energy

11
HC Barcol-Air
Changes w/o notice or obligation.

Product overview

VAV, Fan coil units & Chilled Beams


Dual duct VAV/CAV terminals

Type NZ

Pressure independent
For individual room temperature control
Model 100 to 400
Low leakage damper
High accurate airow sensor
Constant airow to the room
Quiet in operation

Type FCU

Fan coil unit

Horizontal or vertical application


With or without cabinet
Inlet sound attenuator with fresh air connection
optional
Multiple circular outlets section optional
Extended and insulated drip tray
2 pipe change-over or 4-pipe system
Electric heating coil optional

Type AIR-FIT Active Chilled Beam

Using high graded materials


Minimum istallation space
High cooling and heating capacity
Possibility to vary primary air volume

12
HC Barcol-Air
Changes w/o notice or obligation.

Product overview

Diffusers & Grilles


Type VBG

High capacity, circular swirl diffuser


with fully adjustable air pattern

Type CLW

Linear slot diffuser, adjustable air


pattern

Type CSV

Linear Jet Flo

Type PBD

Square perforated ceiling diffuser

13
HC Barcol-Air
Changes w/o notice or obligation.

Product overview

Diffusers & Grilles


Type GFA

Grille, high induction

Type GKB

Grille, aluminuim construction single


and double deection

Type TBW

Wall and Window grille, linear xed


core, 0 / 15 deflection

Type GCJ

High capacity Jet-Flo diffuser


adjustable elements

14
HC Barcol-Air
Changes w/o notice or obligation.

Induction VAV, the optimum indoor climate & energy efcient system

Introduction
Conventional VAV systems have proven in the past to
be very efcient in providing an optimal indoor climate.
However the latest standard and requirements for energy
efciency and human comfort make it more and more
difcult to design conventional VAV systems in new
buildings. From an energy point of view, the minimum air
volume could cause cold air dumping and lack of air
movement in the room, resulting in occupants discomfort
which results in less productivity.

Benets of induction VAV

Up to 100W/m2, without loosing comfort


Cooling, heating and ventilation done by one unit
Perfect ush of the room, also with partial loads, no
cold air dumping
Little space required; small size boxes, relative (30%)
small AHUs and ductwork due to 10-12C primary air
Standard diffusers with reliable performance can be
used
No humidity problems with reliable performance can
be used
Low noise level; terminal unit including sound attenuator
Automatic air ow adjustment when loads are changing
1.25 mm galvanized steel casing prevents breakout
noise and reduces risk torsion during installation
Flo-Cross air volume sensor, ow direction independent, centre averaging, amplied signal and very
accurate ( +/- 2.5%)
Possibility to pre-t and pre-calibrate the VAV controls ( plug and play)
Low maintenance, no fan, no lter, no ns in recirculated air

q2

100

q3

q1

50

min.

50

q1 (%)

15
HC Barcol-Air
Changes w/o notice or obligation.

100

q3 (%)

Combined knowledge VAV & Controls

VAV box with Controls


Compatible with any BMS System

BACnet ( BTL Certied)

LonMark (LON)

Plug & Play works with any 3rd party BMS

Pre-tted

Pre-wired

Pre-calibrated

Pre-tested
Benets of VAV boxes with pre-tted controls

Single sourse

Single responsibility

No coordination

No delays in deliveries

Single service responsibility

Open protocol:LonMark/BACnet

Easy integration with BMS

y
t
i
l
i
b
i
s
n
o
p
s
e
R
e
One Source, On

16
HC Barcol-Air
Changes w/o notice or obligation.

Export reference projects 2006-2007

Reference projects Europe:


UFR de Nantes
Montaury
HPL Nouvelle Clinique
Hospital de Meaux, phase II
Clinique Saint Priest
Centre Hospitalier de Cannes
Neuro 3D
Klinikum Weilmunster
Aluminium Factory
Powerstation Hellis Heidi
TCD Comms
DHL Warehouse
Comune die Bologna
Palestra Verruchio
Ex universita Leon Battista
Ospedale di Tricase
Shakalin Exxon Mobile
Toyota/lexus Showroom
Harvey Norman Store
Drapal, Andjelic and Mikec
Park Hotel Bled
Industrial research Industry
Spital Baar Beulach Bauphase 3
Similason Jona
Ospedale Civico Lugano
OSG Bellinzona Fisioterapia
MMM Neuwiesen Winterthur
Gross Maenendorf
Credit Suisse
Vale Interiors
USB Bank, 6th Broadgate
UKL Wexham Springs
Queen Alexandria Hospital
Deutsche Bank Pinnershall
Nortwick Park Hospital
Nomura House London
Mk dons Stadium Ballroom
Heathrow Air Trafc Control Tower
Flourish-Barclays Capital
Faraday BG Reading
338,Euston Road
Buckinghamshire University
123, Buckingham Palace Road
Broadgate Tower, 201 Bishopsgate
55, Bakerstreet
200, Aldersgate
3rd Hardmann Square
31, Gresham Street
16, Eastcheap
14, Farringdonstreet
IBM Lakeside Bldg, Portsmouth
Manchester Justice Court

Reference projects Africa:


New Flight Kitchen-Catering
Sudapet HQ

France
France
France
France
France
France
France
Germany
Iceland
Iceland
Ireland
Ireland
Italy
Italy
Italy
Italy
Russia
Slovenia
Slovenia
Slovenia
Slovenia
Sweden
Swiss
Swiss
Swiss
Swiss
Swiss
Swiss
Swiss
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom

Ethiopia
Sudan

Reference projects Middle East:


Marriot Hotel
Bahrain City Centre
Trust Insurance Tower
International Insurance Tower
Financial Harbour
Formula 1 circuit
Research Institute of Petrochemical
Central bank of Jordan
Land Rover Showroom
Cooling Industrie
Intercontinental Hotel
Kuwait Oil Tanker Co
Ibis Hotel
Ministry of Interiors
Qatar University
Navigation Tower
Intercontinental Hotel
Science Technology Park
Prince Mohammed University
Private Palace Musafah
Mubadala ERWDA Building
Ministry of Foreign Affairs
Ibis en Novotel
Emirates Airlines Head Quarter
Airport Flower Centre
DAFZA Building 7,8,9
City Hospital
Burj Dubai
Al Salam Tower
Etisalat
2b+G+3 Ofce Building
Standard Chartered Bank
Ministry of Foreign Affairs
Emirates Airlines Head Quarter
Dubai Business Park

Reference projects Far East:


Kun Lun Apartments
Microsoft phase 3
Merrillynch
HSBC @ Softzone
Shell
Google
Yahoo
City Tower
AgaKhan University Hospital
Makro Habib Cash & Carry
Yong Xin Pharmaceutical Project
Abbot Nutrition
NTU-SPMS

Reference projects Australia:

Rhodes
66 Waterloo Road
Citycenter
King Street Wharf
Hyundai HQ

17
HC Barcol-Air
Changes w/o notice or obligation.

Bahrain
Bahrain
Bahrain
Bahrain
Bahrain
Bahrain
Iran
Jordan
Jordan
Jordan
Jordan
Kuwait
Kuwait
Kuwait
Qatar
Qatar
Qatar
Qatar
Saudi Arabia
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates

China
India
India
India
India
India
India
Pakistan
Pakistan
Pakistan
Singapore
Singapore
Singapore

Australia
Australia
Australia
Australia
Australia

Intercontinental Hotel, Aqaba-Jordan


18x VAV terminals + TAC LON controllers

Nomura Bank,London-United Kingdom


500x VAV terminals with integrated sound attenuators and elect.heaters

Media City, Dubai-United Arab Emirates


1000x Induction VAV terminals, cooling only

Bur Juman Center, Dubai-United Arab Emirates


800x High accuracy Flo-Cross air ow sensors

Fund Head Quarters, Abu Dhabi-United Arab Emirates


400x VAV terminals with sound attenuators

USB Bank-Broadgate,London-United Kingdom


150x VAV terminals with integrated sound attenuators and elect.heaters

18
HC Barcol-Air
Changes w/o notice or obligation.

Neuro 3D, Mulhouse-France


20x Laboratory VAV terminals + TAC LON controllers

Heathrow Control Tower, London-United Kingdom


16x special Fan coil units with integrated adjustable diffuser + controls

Financial Harbour, Manama-Bahrain


1800x Induction VAV terminals with TAC BACnet controllers

Formula 1 circuit, Manama-Bahrain


80x VAV terminals, cooling only

Qtel Building, Doha-Qatar


800 x Induction VAV + non-induction VAV terminals

Park Hotel, Bled-Slovenia


150x Fan coil units, cooling and heating

19
HC Barcol-Air
Changes w/o notice or obligation.

Hyundai-HQ, Sydney-Australia
76x Induction VAV terminals, cooling only

Intercontinental Hotel, Doha-Qatar


100 x VAV terminals, cooling only

Etisalat, Dubai-United Arab Emirates


800x VAV terminals, cooling only

Klinikum, Weilmunster-Germany
16x VAV terminals + TAC LON controllers

Bishop Square, London-United Kingdom


200x CAV terminals, rectangular type + sound attenuators and controls

Gulf Library, Abu Dhabi-United Arab Emirates


150x VAV terminals, cooling only

20
HC Barcol-Air
Changes w/o notice or obligation.

2B+G+3 Ofce Building Health Care City, Dubai-United Arab Emirates


100x Induction VAV terminals + TAC LON controllers

City Hospital, Dubai-United Arab Emirates


800x Induction + non-induction VAV terminals + electric heaters

Airport Flower Centre, Dubai-United Arab Emirates


150x Induction + non-induction VAV terminals, cooling only

DAFZA Head Quarters Building + Building 4, 5, 6, 7, 8, 9, Dubai-United


Arab Emirates, 4,500 x Pressure Independent VAV terminals

Insurance Tower, Manama-Bahrain


400x Induction VAV terminals + TAC BACnet controllers

Emaar Business Park, Dubai-United Arab Emirates


1800x Induction VAV terminals, cooling only

21
HC Barcol-Air
Changes w/o notice or obligation.

Distributor list

Europe
Reliance Engineering Services Ltd.
MWH Barcol-Air
MWH Barcol-Air France
Invent Technika Kft.
Rafn Jensson Mechanical Engineers
Coolair Ltd.
Contel Automation & Control Ltd.
Ofcine Volta S.p.A.
Intelligent Building Systems Sp. z o.o.
AHI Carrier
Vavtar Ineniring d.o.o.
Hiensch Engineering AB
MWH Barcol-air AG
Barcol-Air UK Ltd.

Nicosia
Malling
Cergy Pontoise Cedex
Budapest
Reykjavik
Dublin
Petach-Tikva
Bologna
Wroclaw
Moscow
Ljubljana
Stockholm
Stfa
Bath

Cyprus
Denmark
France
Hungria
Iceland
Ireland
Israel
Italy
Poland
Russia
Slovenia
Sweden
Switzerland
United Kingdom

Santa Clara

USA

America
MWH Barcol-Air USA

22
HC Barcol-Air
Changes w/o notice or obligation.

Distributor list

Middle-East
Almoayyed Air Conditioning
Air Master Equipments India (P) Ltd.
Westech Air Equipments
Sauter Race Technologies Pvt. Ltd.
Takvin Resaneh
ACE Supplies & Trading Co.
Bader Al Mulla & Brothers Co.W.L.L.
Dan International LLC
Instrumentation & Management Systems
Shahjan Trading Establishment
Danway LLC
Bahri & Mazroei Technical Systems Co. (LLC)
Independent Technical Solutions LLC
Al Taqa Equipment Est.

Manama
Bangalore
Bombay
Chennai
Tehran
Amman
Safat
Muscat
Karachi
Doha
Dubai
Dubai
Dubai
Abu Dhabi

Bahrain
India
India
India
Iran
Jordan
Kuwait
Oman
Pakistan
Qatar
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates

Norwood
Dhaka
Hong Kong
Jakarta
Manila
Singapore
Colombo
Taipei

Australia
Bangladesh
Hong Kong
Indonesia
Philippines
Singapore
Sri Lanka
Taiwan

Far-East
Air Con Serve Pty. Ltd.
Xebec Trading Services
Starec Ltd.
PT Barcol-Air
Air Filter
Barcol Air Engineering Pte Ltd
Southern Automation Systems (Pvt) Ltd.
Barcol Industries

23
HC Barcol-Air
Changes w/o notice or obligation.

HC Barcol-Air

P.O. Box 283, 1440 AG Purmerend - The Netherlands


T +31 (0)299 689 300 | F +31 (0)299 436 932
info@barcol-air.nl | www.barcol-air.nl
HC Barcol-Air is part of

Vous aimerez peut-être aussi