HC Barcol-Air
Changes w/o notice or obligation.
Preface
True-out this company prole we hope to give you a good
impression of our company and products.
Lars Wiersma
Export Manager
2
HC Barcol-Air
Changes w/o notice or obligation.
Table of content
Subject
Page
Preface
Table of content
Company introduction
Mission statement
Facts & gures
4
4
Company vision
Introduction HC Groep
Prole
8 - 10
Product overview
11 - 14
Induction VAV, the optimum indoor climate & energy efcient system
15
16
References
17 - 21
Distributor list
22 - 23
HC Barcol-Air continuously aspires to further optimise the construction and the quality of all products. HC Barcol-Air preserve themselves the right
to carry out modications in product specications without notice or obligation.
S.E. & O.
Copyright Barcol-Air B.V. 2008
Nothing from this publication may be multiplied and/or made public by means of printing, photocopy, microlm or in whatever manner, without
preceding written authorisation of HC Barcol-Air.
3
HC Barcol-Air
Changes w/o notice or obligation.
Company introduction
Mission statement
4
HC Barcol-Air
Changes w/o notice or obligation.
Company vision
Introduction
History
Designing and developing products and systems to create and control the environment in commercial buildings
using the minimum energy and providing with optimal
comfort.
The origin dates back to 1932, when Barber Colman started de develop Air Distribution, products and controls.
1900
1935
1982
1987
1998
Responsibility
e
n
O
,
e
c
r
u
o
S
One
Timeline:
Current Situation
On April 1st , 2006 Barcol-Air B.V. was taken over by the
HC Groep, a market leader in the Netherlands, who can
offer a total comfort solution including design, testing and
commissioning.
5
HC Barcol-Air
Changes w/o notice or obligation.
Introduction HC Groep
Integral supplier
Combined strength
Versatile, high quality standards, exible and customerminded. Because of these high standards, consultants,
architects and contractors have been calling upon the
companies within the HC Groep.
Unity in diversity
The HC Groep consist of seven companies, each of them
fully aware of the latest market requirements and in direct
contact with business related partners.
The following overview pictures the different companies:
Chillers / WP
Air curtains
Roof fans
CCU / Dry coolers
Ventilation concepts
9 series
Own coils
TB1/T1
Eurovent certied
Ventilation systems
CO detection
Fire detection
Switchboard
Climate ceilings
Metal ceilings
Industrial ceilings
Plaster ceilings
Air climate ceilings
Ventilation systems
CO/LPG detection
Fire detection
Switchboard
6
HC Barcol-Air
Changes w/o notice or obligation.
Prole
Organization
HC Barcol-Air consist of two main divisions: Air Distribution and Controls
Air Distribution Product:
Development
Production
Support
Controls products/BMS:
Engineering
Call-out service
Service contracts
End of Warranty
Organization
Management
Financial Administration
Marketing
R&D
Climate room
Air Distribution
Development
Production
Sales Domestic
Export
Support
Controls
Internal Operations
Domestic Sales
Project management
Supply & Installation
Wiring & Panels
Software & Commissioning
Service & support
Call-out
Contracts
Refurbishment Upgrades
End of Warranty
Order handling
Procurement
Logistics
Production
Warehouse
Quality
7
HC Barcol-Air
Changes w/o notice or obligation.
Introduction
Measuring robot
Climate laboratory
The purpose of a full-scale climate laboratory test is to
give the principal, designer and consultant maximum
security about the installations design, in an early stage.
Especially when the design is completely new, not often
used or when the building has specic characteristics,
a climate laboratory test can prevent a lot of problems during construction or even after commissioning.
HC Barcol-Airs climate room in Purmerend (Netherlands)
has a maximum oor space of approx. 8 x 8 meter with
exible positional walls and ceiling up to a height of 3.3
meter . To perform full-scale tests, the room is built with
exact (actual) dimensions. The climate faade simulates
the outdoor conditions and can be cooled to simulate winter conditions and heated to simulate summer conditions.
Uniquely this test room has two climate facades from
bottom to ceiling, which enables to test also (complicated) corner rooms.
Mock-ups are not only built with actual dimensions but
also faade, ceiling, furniture, oor covering, convectors
and lightning can be built according to project specication. There is also the possibility of building special
application rooms like hospital rooms, dealing rooms,
laboratories and so on.
Fixed sensors
Besides the sensors on the measuring robot, there are
also sensors mounted on xed places for primary air temperature, supply air temperature, air volume, reference
room temperature, windowpane surface temperature (inand outside) and surrounding temperature.
8
HC Barcol-Air
Changes w/o notice or obligation.
Standards
Reporting
9
HC Barcol-Air
Changes w/o notice or obligation.
Introduction
HC Barcol-Air has built a reverberation room for predesign sound testing of products and systems. This enables Barcol-Air to test products and systems for thermal
indoor climate as well as sound production and absorption.
Acoustic performance
The test at HC Barcol-Air is executed in a reverberation
room (not certied), which has a volume of 65 m and a
reverberation time of 2.2 - 2.5 seconds.
Measurements are being executed through a calibrated
sound meter fabricated by Delta Ohm type HD2010,
which can determine the reverberation time for each
room/test set-up individually.
Reverberation room
H=2,70m
600
Acoustic calculations
The measured sound levels will be corrected with the
background noise and the reverberation time of the room,
which will also be measured both individually.
The measured sound power levels for the mid ranges
of frequency band 125 8,000 Hz and NR levels will be
presented in table and graph form.
399
Opening in wall
max. 110x150cm
(BxH)
200
432
H=2,90m
10
HC Barcol-Air
Changes w/o notice or obligation.
Product overview
VAV units
Type NA/NB
Pressure independent
For individual room temperature control
Model 100 to 400
Single or double wall construction
Compact
Low leakage damper
High accurate airow sensor
Quiet in operation
Type NK/NL
Pressure independent
For individual room temperature control
Size 200x150 to 2000x1000mm
Single or double wall construction
350 mm installation length
Low leakage damper
High accurate airow sensor
Quiet in operation
VAV terminal with integrated soundattenuator
Pressure independent
For low noise requirements in high pressure or
high velocity systems
Model 100 to 400
Compact in size
Low leakage damper
High accurate airow sensor
Very quiet in operation
Type NS
Type NV
Pressure independent
For comfortable air distribution in systems with
high load variation
Model 100 to 400
Low leakage damper
High accurate airow sensor
Very quiet in operation
Provides savings in energy
11
HC Barcol-Air
Changes w/o notice or obligation.
Product overview
Type NZ
Pressure independent
For individual room temperature control
Model 100 to 400
Low leakage damper
High accurate airow sensor
Constant airow to the room
Quiet in operation
Type FCU
12
HC Barcol-Air
Changes w/o notice or obligation.
Product overview
Type CLW
Type CSV
Type PBD
13
HC Barcol-Air
Changes w/o notice or obligation.
Product overview
Type GKB
Type TBW
Type GCJ
14
HC Barcol-Air
Changes w/o notice or obligation.
Induction VAV, the optimum indoor climate & energy efcient system
Introduction
Conventional VAV systems have proven in the past to
be very efcient in providing an optimal indoor climate.
However the latest standard and requirements for energy
efciency and human comfort make it more and more
difcult to design conventional VAV systems in new
buildings. From an energy point of view, the minimum air
volume could cause cold air dumping and lack of air
movement in the room, resulting in occupants discomfort
which results in less productivity.
q2
100
q3
q1
50
min.
50
q1 (%)
15
HC Barcol-Air
Changes w/o notice or obligation.
100
q3 (%)
LonMark (LON)
Pre-tted
Pre-wired
Pre-calibrated
Pre-tested
Benets of VAV boxes with pre-tted controls
Single sourse
Single responsibility
No coordination
No delays in deliveries
Open protocol:LonMark/BACnet
y
t
i
l
i
b
i
s
n
o
p
s
e
R
e
One Source, On
16
HC Barcol-Air
Changes w/o notice or obligation.
France
France
France
France
France
France
France
Germany
Iceland
Iceland
Ireland
Ireland
Italy
Italy
Italy
Italy
Russia
Slovenia
Slovenia
Slovenia
Slovenia
Sweden
Swiss
Swiss
Swiss
Swiss
Swiss
Swiss
Swiss
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
Ethiopia
Sudan
Rhodes
66 Waterloo Road
Citycenter
King Street Wharf
Hyundai HQ
17
HC Barcol-Air
Changes w/o notice or obligation.
Bahrain
Bahrain
Bahrain
Bahrain
Bahrain
Bahrain
Iran
Jordan
Jordan
Jordan
Jordan
Kuwait
Kuwait
Kuwait
Qatar
Qatar
Qatar
Qatar
Saudi Arabia
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
China
India
India
India
India
India
India
Pakistan
Pakistan
Pakistan
Singapore
Singapore
Singapore
Australia
Australia
Australia
Australia
Australia
18
HC Barcol-Air
Changes w/o notice or obligation.
19
HC Barcol-Air
Changes w/o notice or obligation.
Hyundai-HQ, Sydney-Australia
76x Induction VAV terminals, cooling only
Klinikum, Weilmunster-Germany
16x VAV terminals + TAC LON controllers
20
HC Barcol-Air
Changes w/o notice or obligation.
21
HC Barcol-Air
Changes w/o notice or obligation.
Distributor list
Europe
Reliance Engineering Services Ltd.
MWH Barcol-Air
MWH Barcol-Air France
Invent Technika Kft.
Rafn Jensson Mechanical Engineers
Coolair Ltd.
Contel Automation & Control Ltd.
Ofcine Volta S.p.A.
Intelligent Building Systems Sp. z o.o.
AHI Carrier
Vavtar Ineniring d.o.o.
Hiensch Engineering AB
MWH Barcol-air AG
Barcol-Air UK Ltd.
Nicosia
Malling
Cergy Pontoise Cedex
Budapest
Reykjavik
Dublin
Petach-Tikva
Bologna
Wroclaw
Moscow
Ljubljana
Stockholm
Stfa
Bath
Cyprus
Denmark
France
Hungria
Iceland
Ireland
Israel
Italy
Poland
Russia
Slovenia
Sweden
Switzerland
United Kingdom
Santa Clara
USA
America
MWH Barcol-Air USA
22
HC Barcol-Air
Changes w/o notice or obligation.
Distributor list
Middle-East
Almoayyed Air Conditioning
Air Master Equipments India (P) Ltd.
Westech Air Equipments
Sauter Race Technologies Pvt. Ltd.
Takvin Resaneh
ACE Supplies & Trading Co.
Bader Al Mulla & Brothers Co.W.L.L.
Dan International LLC
Instrumentation & Management Systems
Shahjan Trading Establishment
Danway LLC
Bahri & Mazroei Technical Systems Co. (LLC)
Independent Technical Solutions LLC
Al Taqa Equipment Est.
Manama
Bangalore
Bombay
Chennai
Tehran
Amman
Safat
Muscat
Karachi
Doha
Dubai
Dubai
Dubai
Abu Dhabi
Bahrain
India
India
India
Iran
Jordan
Kuwait
Oman
Pakistan
Qatar
United Arab Emirates
United Arab Emirates
United Arab Emirates
United Arab Emirates
Norwood
Dhaka
Hong Kong
Jakarta
Manila
Singapore
Colombo
Taipei
Australia
Bangladesh
Hong Kong
Indonesia
Philippines
Singapore
Sri Lanka
Taiwan
Far-East
Air Con Serve Pty. Ltd.
Xebec Trading Services
Starec Ltd.
PT Barcol-Air
Air Filter
Barcol Air Engineering Pte Ltd
Southern Automation Systems (Pvt) Ltd.
Barcol Industries
23
HC Barcol-Air
Changes w/o notice or obligation.
HC Barcol-Air