Vous êtes sur la page 1sur 5

GE

Intelligent Platforms

PAC POWER
Industrial grade power supply
Rail mounted, fan-less design

The PAC Power includes all the essential


basic functions and the devices have a
power reserve of 20%. This extra current
may even be used continuously at
temperatures up to +45C. The most
important features are the small size, the
high efficiency and the wide
temperature range.
The Auto-select input makes worldwide
installation and usage very simple.
Defects or system failures caused by
wrongly set switches cannot occur.

Innovation
Using the most advanced power
technology, compact and highly reliable.
Minimalist design makes more petite
size, lighter weight.

Reliable
It can be widely used in various harsh
operating environments, no matter
which model you are using a switching
power supply, you get the best quality
and most reliable products.

Unique security
Short circuit, over load, over voltage,
over temperature protection and
multiple protection, as well as a very
wide input voltage range, very low
input inrush current, supply voltage can
calmly deal with ups and downs, load
short-circuit caused by external factors
such as interference.
A variety of add-on modules that can
provide protection against a variety of
security risks.

Flexible Installation
Rail mounting, if it is at the request, it
also support bracket installation.

Specification:
Items

Part Number
Output voltageV
Output currentA
Current rangeA
Output PowerW
Peak CurrentA
Peak PowerW

Output

Input

Ripple
and
noise
voltagemVp-p
Adjustment rangeV
Factory setting%
Line regulation max.
Load regulation max.
Hold-up TimeTyp.At
full load
note2
AC input range
Input frequencyHz
Power factorTpy.At
full load
Efficiency Tpy. At
full load
AC Input currentTpy.
At full load
AC
Inrush
current
Tpy.
DC-OK RELAY CONTACT
Status

Functio
n

Overload behavior

Protect

Output
over-voltage
protection

ENVIRON
MENT

SAFETYF
FEATURE
S &EMC

others
Note 1:

Over-temperature
protection
Operational temperature
note3
C
Humidity%RH
Storage
temperature,
Humidity
Output
de-rating
+60~+70C
Input
/
output
separation SELV
Conducted
emission
input lines
EMC Immunity
Sizemm
WxHxD
Weightkg
Packing
for typ. 4s

IC690PRM005

IC690PRM010

IC690PRM210

IC690PRM120

IC690PRM240

24
5
0~5
120
6
144ambient
<45C
50

70
100
63ms/230VAC
180~264Vac

0.5/230VAC

10
0~10
240
12
288ambient
<45C
50

70
100
47ms/230VAC,46ms/120
VAC
90~132VAC or
180~264VAC

3 A/230VAC

0.51/230VAC,0.59/120
VAC
91.6/230VAC,91/120VA
C
2.23A/230VAC,3.73A/1
20VAC
3A/230VAC,3A/120VAC

NA
NA

NA
NA

90.2/230VAC,
1.23A/230VAC

10
0~10
240
15
note1
360

20
0~20
480
24
576 ambient <45C

40
0~40
960
60
note1
1440

50

50

100

10
100
26ms/230VAC,26ms/120VA
C
85~264VAC

10
50
30ms/230VAC

0.95/230VAC,0.99/120VA
C
94/230VAC,92.7/120VAC

0.96/230VAC

2.33A/230VAC,4.36A/120
VAC
7A/230VAC,9A/120VAC

4.6A/230VAC

24~28
+-0.2%24.1V
10
100
28ms/230VAC,27ms/120VAC
85~276VAC or 88~187VDC
47~63
0.92/230VAC,0.98/120VAC
93.5/230VAC,92.6/120VAC
1.22A/230VAC,2.22A/120VAC
7A/230VAC,4A/120VAC

170~264VAC

94.6/230VAC

14A/230VAC

60VDC/0.3A30VDC/1A30VAC/0.5A resistive load


Contact closesContact closes-As soon as
Contact closes-As
As soon as the output
the output voltage reaches
soon as the output
voltage reaches the
90% of the adjusted output
voltage reaches 90%
adjusted output voltage
voltage level.
of the adjusted
level.
output voltage
Contact opens- As soon as
Contact openslevel.
the output voltage dips more
As soon as the output
Contact opens- As
than 10% below the adjusted
voltage dips more than
soon as the output
output voltage. Short dips
10% below the adjusted
voltage dips more
will be extended to a signal
output voltage.
than 10% below the
length of 100ms.
adjusted output
voltage.
20% Output Power
20% Output Power
50% Output Power
20% Output Power Reserves,
50% Output Power
Reserves, can
Reserves, can
Reserves, can
can continuously work within
Reserves, can
continuously work
continuously work
continuously work within
this range
continuously work
within this range
within this range
this range
within this range
At heavy overload
At heavy overload
At heavy overload
At heavy overload (>120%),
At heavy overload
(>120%), the
(>120%), the
(>150%), the switched off
the power supply delivers
(>150%), the
switched off before
switched off before
before a new start
continuous output current
switched off before
a new start attempt
a new start attempt
attempt is automatically
for 2s. After this, the
a new start attempt
is automatically
is automatically
performed.
output is switched off for
is automatically
performed.
performed.
approx. 18s before a new
performed.
start attempt is
automatically performed.
Max. 39
Max.39
Max. 39
Max.32
Max.32
In case of an internal power supply defect, a redundant circuit limits the maximum output voltage. The output shuts down and
automatically attempts to restart.
Output shut-down with automatic restart
-25 ~ +70
5~95no condensation
-40 ~ +85C5~95%RH
3W/C

6W/C

6W/C

12W/C

24W/C

IEC60950-1
EN55011EN55022CISPR22
Class BEN61000-3-3
32x124x117
0.5

60x124x117
0.7

EN55011EN55022CISPR22Class BEN61000-3-2, -3
EN61000-4-2,3,4,5,6,8,11
60x124x117
0.9
16pcs/Box

65x124x127
1.0

125x124x127
1.8
8pcs/Box

Note 2: continuous operation


Note 3: Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit

Installation size
IC690PRM005

IC690PRM010

IC690PRM210

IC690PRM120

IC690PRM240

Other installtion option


IC690PRA001

IC690PRA002

Redunancy system optionavailable to IC690PRM010, IC690PRM210, IC690PRM120, IC690PRM240


IC690PRS010

IC690PRS020

IC690PRS040

GE Intelligent Platforms Contact Information


Greater China: 86 400 820 8208
Global regional phone numbers are listed by location on our web site at www.ge-ip.com/contact

www.ge-ip.com
2012 GE Intelligent Platforms, Inc. All Rights Reserved.
All other brands or names are property of their respective holders.
Specifications are subject to change without notice.

Vous aimerez peut-être aussi