Académique Documents
Professionnel Documents
Culture Documents
8
9
2
1
10
MIN
COOL
SPEED
HI
LOW
ON
OFF
MAX
COOL
FAN ONLY
HWR05XC7
0010551959
POWER
6-7
8-11
8
8-11
12-16
13
13
14-16
17-18
18-19
20
easy
access
filters
2-way
airflow
control
panel
8
9
2
1
10
MIN
COOL
SPEED
HI
LOW
ON
OFF
MAX
COOL
FAN ONLY
MODEL: HWF05XC5
POWER
easy
access
filters
2-way
airflow
control
panel
TIME ON
TIME OFF
HI SPEED
LOW SPEED
FAN
COOL
POWER
ON/OFF
MODEL: HWR05XC5
2. fan Speed
MODEL: HWF05XC5
9
1
10
MIN
COOL
MAX
COOL
SPEED
HI
LOW
ON
OFF
FAN ONLY
POWER
CAUTION:
1
2 Also when you shut off the air conditioner wait for 3 minutes
MODEL: HWR05XC5
Control Panel
1
ON/OFF
TIME ON
TIME OFF
MODE
SPEED
TIMER
HI SPEED
LOW SPEED
4
TEMP/TIME
FAN
COOL
POWER
ON/OFF
10
1. ON/OFF
To turn set ON, press the button. To turn set OFF, press the button again.
2. TIMER
Press TIMER button, for each press, TIMER mode will changes as follows:
TIMER ON
TIMER OFF
CANCEL
3. FAN
Pressing the FAN button changes between LOW and HIGH SPEED.
4. MODE
Every time you press this button, it will change between COOL and FAN.
5. TEMP. /TIME
Used to set temperature and time.
11
12
top rail
MODE
SPEED
TIMER
TEMP/TIME
CR2025
Remote
control
ba t t ery
Model: HWR05XC5
13
8
9
2
1
10
MIN
COOL
SPEED
HI
LOW
ON
OFF
MAX
COOL
FAN ONLY
POWER
HWF05XC5,HWR05XC5
31
1 32
11 58
11 13
16
34 167
20 15
32
11 167
17 165
13
13 32
ASSEMBLE
CURTAINS/TOP RAIL
Install top rail with 3 short
screws13/32".
Insert the side curtains into the
top and bottom rails of the air
conditioner. Fasten the curtains
to the unit with 8 short screws
13/32".
14
INNER
SILL
I
N
D
1. This unit is designed for installation in standard double hung
O windows
O
with actual opening
of 21and lower sash
to 35
.widths
The upper
must open sufficiently to allow
a clear
from
the vertical opening of 12 R
S
LOCATING UNIT IN
WINDOW
Open the window and mark center line on the
center of the inner sill .
CENTER LINE
3/4 CLEARANCE
STORM
WINDOW FRAME
OUTER
SILL
O
U
T
D
O
O
R
S
ATTACH BASEPAN
ANGLE
Install the basepan angle behind the inner window sill , with
the short side of basepan angle as shown. Use the 2 short
screws13/32" provided.
The basepan angle helps to hold unit securely in place.
Be sure to place basepan angle edge flush against back
of inner sill .
INNER SILL
INNER SILL
O
U
T
D
O
O
OUTER R
SILL S
SHORT SCREW13/32"
CENTER LINE
OUTER SILL
INSIDE
7,5
INDOOR SIDE
SHORT SIDE
7,5
OUTSIDE
BASEPAN ANGLE
15
WINDOW FRAME
UPPER GUIDE
Carefully lift the air conditioner and slide it into the open
window. Make sure the bottom guide of the air conditioner
drops into the notches of the basepan angle.
While steadying the air conditioner ,carefully bring the
window sash down behind the upper guide of the air
conditioner.
ABOUT 1/4
BOTTOM GUIDE
BASEPAN ANGLE
BASEPAN ANGLE
SHORT SCREW13/32"
Extend the side curtains to fill the
window opening using 4 wood screws
31/32" to secure them.
Cut the seal gasket to the window
width. Stuff the sash seal between the
glass and the window to prevent air WOOD SCREW31/32"
and insects from getting into the room.
Fasten the basepan angle, using a
short screw13/32".
16
The air filter behind the inlet grille should be checked and cleaned at
every 2 weeks (or as necessary) to maintain optimal performance of the a
conditioner.
How to remove the air filter
1. The grille may be opened from the top for easy maintenance after inst
2. Open the inlet grille by pulling off the exposed door on the top of t
on the installation).
3. Pull the tab slightly to release the filter. Pull the filter in the sa
the opening.
4. Clean the filter with warm, soapy water. The water should be below 40
5. Rinse off and gently shake off excess water from the filter. Let it d
replacing it .
DO NOT use your air conditioner without the air filter in place.
17
18
(see page 8)
19