Vous êtes sur la page 1sur 120

Name of Package:

Package Code
Specification No.

Completion Period

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Connectivity with
Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP
Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system for Ultra Mega Solar
Park in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation including
supply of 1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Mega Solar
Park in Anantapur Distt, AP-Part-C.

Substation Package-SS02

Specification No.: CC-CS/675-SR1/SS-3256/3/G5


22
10
12

REV-02

General guidelines for filling up the Price Schedules, Sch-1 to Sch-7

AAABAABBA

Price Schedules

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Connectivity with
Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP
Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system for Ultra Mega Solar
Park in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation including
supply of 1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Mega Solar
Park in Anantapur Distt, AP-Part-C.
Specification No.: CC-CS/675-SR1/SS-3256/3/G5
1

Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-4, Sch-5, Sch-7 and Bid Form
2nd Envelope.

All the cells in 'Sch-6' & 'Sch-6 After Discount' are auto filled, therefore no cell is required
to be filled up there.

Instructions / error messages, if any, will be displayed automatically after selecting the
cell.
Click for Detailed General Instructions

Click to skip Instructions & Proceed


( )

Power Grid Corporation of India Limited


(A Government of India Enterprises)

Click to skip Instructions & Proceed

Substaion Package Substation Package-SS02

g up the Price Schedules, Sch-1 to Sch-7

General Instruction to the Bidders for filling up this workbook of P


I

While filling up the worksheets following may please be observed :


(i)
(ii)
(iii)
(iv)
(v)
(vi)

II

This Workbook consists of following worksheets :


Cover :
Names of Bidder :

Sch-1 (Ex-works Prices) :

Sch-2 (Freight & Insurance Charges) :

Page 6 of 120

Page 7 of 120

Sch-3 (Erection Charges) :

Sch-4 (Training Charges) :

Sch-5 (Summary of Taxes and Duties applicable on the Goods) :

Entry Tax :

OCTROI :
Page 8 of 120

Other Taxes & Duties :

Sch -6 :

Sch-7 (Type Test Charges) :

Bid from 2nd Envelope :

***
Happy Bidding !

Page 9 of 120

eral Instruction to the Bidders for filling up this workbook of Price


Schedules

While filling up the worksheets following may please be observed :


Fill up only green shaded cells.
Certain data type entries have been restricted, such as Numeric values or limits of
numeric values.
Select only the options provided in pull down menus.
Do not link any cell of this work book with any other work book.
Do not use copy & paste or cut & paste options for filling up the data.
Do not reformat any of the cell of the work book.

his Workbook consists of following worksheets :


Cover :
Opening page of the workbook.
Names of Bidder :
Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this
cell blank.
Select nos. of the JV Partners other than the Lead Partner from drop down menu.
In case of JV partners more than 2, enter details of 3rd & more partners along with
details of 2nd partner.

Fill up names and address of the Sole Bidder and /or Joint Venture.
Fill up date in dd-mmm-yyyy format from drop down menu.
Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate
is left blank, the corresponding item shall be deemed to be included in the total
price.
Corresponding cell for mode of transaction shall be come enable only after filling up
the unit rate, therefore first fill up the unit rate and then mode of transaction for the
corresponding item.
Select either Direct or Bought-out from the drop down menu. Do not leave the cell
blank the same shall be deemed to be Bought-out if the cell is left blank.
Total amount shall get calculated automatically.
Type Test charges shall appear automatically after filling up Sch-7 appropriately.

Sch-2 (Freight & Insurance Charges) :

Page 10 of 120

Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate
is left blank, the corresponding item shall be deemed to be included in the total
price.
Total amount shall get calculated automatically.

Page 11 of 120

Sch-3 (Erection Charges) :


Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate
is left blank, the corresponding item shall be deemed to be included in the total
price.

Total amount shall get calculated automatically.


Sch-4 (Training Charges) :
Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items
mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated
automatically at the rate mentioned by the bidder here.
Segregate and fill up the amount on which Sales Tax shall be applicable out of Exworks supply items mentioned as direct in the mode of transaction in Schedule-1.
Applicable Excise Duty on this amount will be calculated automatically at the rate
mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of
Sales Tax shall be automatically calculated on the amount mentioned by the bidder
as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the
Bidder.

Difference of total amount quoted by the bidder as Direct Transaction and the
amount mentioned by him subjected to Sales Tax shall be considered as the
amount on which VAT shall become applicable and the same shall be calculated &
displayed automatically. Applicable Excise Duty on this amount at the rate
mentioned by the bidder shall also be calculated & displayed automatically. Fill up
the rate of applicable VAT. The amount of VAT shall be calculated automatically on
the amount considered to be subjected to VAT plus applicable Excise Duty at the
rate mentioned by the bidder here.

Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi
and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be
added to the grand total and shall be considered as applicable.

Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes &
Duties one by one.

Entry Tax :
Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet
shall be displayed in Sch -5 (Taxes & Duties)
Click at the link to go back to Sch-5.

OCTROI :
Page 12 of 120

Fill the description, amount and rate of applicable Octroi. Total of this worksheet
shall be displayed in Sch -5 (Taxes & Duties)

Click at the link to go back to Sch-5.


Other Taxes & Duties :
Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this
worksheet shall be displayed in Sch -5 (Taxes & Duties)
Click at the link to go back to Sch-5.

Sch -6 :
Summary of all the Schedules without considering discount (mentioned in the work
sheet discount) shall be displayed automatically.
No cell is required to be filled in by the bidder in this worksheet.

Sch-7 (Type Test Charges) :

Fill up the rates & location where type tests are proposed.
Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
Fill up ref. no. as bidder's ref no. of this letter.
This letter shall consider the net price as per Sch-6 (After Discount).
Fill up names & Designation of the representatives of other JV partner(s) if the
bidder is JV (Joint Venture) .
Fill up additional information as required.

***
Happy Bidding !

Page 13 of 120

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Conne
with Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension
400/220kV NP Kunta Substation (with 4 nos. of 220kV line bays) under Transmission syste
Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Su
including supply of 1x500MVA, 400/220kV Autotransformer under Transmission system fo
Mega Solar Park in Anantapur Distt, AP-Part-C.
Specification No.: CC-CS/675-SR1/SS-3256/3/G5
Enter following details of the bidder
Specify type of Bidder
from drop down menu]

[Select

Sole Bidder

2 or More
Name of Sole Bidder
Address of Sole Bidder

Name of other Partner - 1


Address of other Partner - 1
.. .. .. .. .. ..
.. .. .. .. .. ..
Name of other Partner - 2 (more, if any)

.. .. .. .. .. ..

Address of other Partner - 2 (more, if any)

.. .. .. .. .. ..
.. .. .. .. .. ..
.. .. .. .. .. ..

Printed Name
Designation

Date
Place

kV Tuticorin substation under Connectivity


e Transmission System ii)Extension of
line bays) under Transmission system for Ultra
Extension of 400/220kV NP Kunta Substation
ormer under Transmission system for Ultra

5-SR1/SS-3256/3/G5

s of the bidder

Sole Bidder

2 or More

.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..

fication No.: CC-CS/675-SR1/SS-3256/3/G5

Schedule - 1
REV-02

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Connectivity with Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System
ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system for Ultra Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension
of 400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.
(SCHEDULE OF RATES AND PRICES)

ders Name and Address (Sole Bidder) :

To:

Name

Contract Services
Power Grid Corporation of India Ltd.,

Address

"Saudamini", Plot No.-2


Sector-29,
Gurgaon (Haryana) - 122001

Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted
All Prices are in Indian Rupees.
SI. No.

PR No

PR Line
Item No

Material Code

Header Description

Item Description

Unit

Qty.

Unit Ex-works
price

Total Ex-works
price

Mode of Transaction
(Direct / Boughtout)^

10 = 8 x 9

11

400KV KUDANKULAM BAY EXTN. AT TUTICORIN

7000001131

10

1000004489 420KV EQUIPMENTS

420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor

EA

0.01

7000001131

20

1000004461 420KV EQUIPMENTS

EA

0.01

7000001131

30

1000004483 420KV EQUIPMENTS

420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120%


extended currentrating
420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S

EA

0.01

40
50
60
70

6
6
6
2

7000001131

80

420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)


336kV Surge Arrester (1-phase)
420 kV, 1 phase Bus Post Insulator (except for Line Traps)
400kV Circuit Breaker Relay Panel with Auto Reclose (with
Automation)
400kV Line Protection Panel (with Automation)

EA
EA
EA
EA

EA

0.01

7000001131
7000001131
7000001131
7000001131

90
100
110
120

1000004535 420KV EQUIPMENTS


1000020419 420KV EQUIPMENTS
1000004401 420KV EQUIPMENTS
1000002165 CONTROL & RELAY PANEL (WITH
AUTOMATION)
1000003398 CONTROL & RELAY PANEL (WITH
AUTOMATION)
1000000003 PLCC SYSTEM
1000004400 PLCC SYSTEM
1000014547 ILLUMINATION SYSTEM
1000020262 ILLUMINATION SYSTEM

0.01

6
7

7000001131
7000001131
7000001131
7000001131

EA
EA
EA
EA

4
12
1
2

0.01

130
140
150
160
170

1000014535 ILLUMINATION
1000014536 ILLUMINATION
1000014534 ILLUMINATION
1000021982 ILLUMINATION
1000020192 STRUCTURE

EA
EA
EA
EA
EA

20
20
5
5
6

0.01

17

7000001131
7000001131
7000001131
7000001131
7000001131

400kV,3150A,1.0mH , 50kA Line Trap


420 kV ,1 phase Bus Post Insulators for Line Traps
Lighting Panel type ACP-2 as per technical specification
Sub Lighting panel (outdoor) type SLP (Switchyard and Street
Lighting)
Lighting Fixture type-SF1 as per technical specification
Lighting Fixture type-SF2 as per technical specification
Lighting Fixture type SC as per technical specification
Street Lighting pole type A1 as per technical specification.
Fabrication, galvanising and supply ofStandard Pipe Structure - 400
kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates,
step boltsand gusset plates excluding foundationbolts

18

7000001131

180

1000020193 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 400kV CVT including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA

0.01

10
11
12
13
14
15
16

SYSTEM
SYSTEM
SYSTEM
SYSTEM

0.01
0.01
0.01

0.01
0.01
0.01

0.01
0.01
0.01
0.01

Schedule-1/ Page 16 of 120

All Prices are in Indian Rupees.


SI. No.

PR No

Header Description

Item Description

Qty.

Unit Ex-works
price
9

Total Ex-works
price

190

1000020194 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers,
packplates,step bolts and gusset plates excludingfoundation bolts

EA

10 = 8 x 9
0.01

20

7000001131

200

1000020195 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,1-Phase, SA including nuts, bolts,all type of washers, packplates,
stepbolts and gusset plates excludingfoundation bolts

EA

0.01

21
22

7000001131
7000001131

210
220

1000017567 STRUCTURE
1000020197 STRUCTURE

Standard Pipe Structure for 400kV BPI (excluding wave trap)


Fabrication, galvanising and supply of Std Pipe Structure - 400 kV
WTincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA
EA

6
4

0.01
0.01

23

7000001131

230

1000012366 STRUCTURE

EA

264

0.01

24

7000001131

240

1000011320 ERECTION HARDWARE

SET

0.01

25

7000001131

260

1000000442 POWER & CONTROL CABLE

LS

0.01

26

7000001131

270

1000000443 POWER & CONTROL CABLE

LS

0.01

27

7000001131

280

1000004488 MANDATORY SPARES

Fabrication, galvanising and supply of 28mm dia foundation


boltsincluding nuts, checknuts, washers and packplates.
Erection Hardware for 400kV I type layout-Any feeder Extn. on
existinghalf dia. as per technical specification
1.1kV grade Control Cables (PVCinsulated) along
withlugs,glands,straight joints &accessories,etc.
1.1kV grade Power Cables (PVCinsulated)along
withlugs,glands,straight joints &accessories,etc.
One Pole of 420kV, 315 A, 50kA SF6circuit breaker with PIR
includinggrading capacitor (if applicable),Polecolumn interrupter,
with drivingmechanism and Marshaling Box butwithout support
structure.

EA

0.01

28

290
300
310
320
330
340

1000021861 MANDATORY
1000009197 MANDATORY
1000021444 MANDATORY
1000015549 MANDATORY
1000009860 MANDATORY
1000018381 MANDATORY

SET
EA
EA
EA
SET
SET

1
1
1
1
1
1

34

7000001131

350

1000017844 MANDATORY SPARES

Trip coil with resistor for 420kV SF6 Circuit Breaker


Closing coil with resistor for 420kV SF6 Circuit Breaker
Terminal pad for 420kV SF6 Circuit Breaker
Molecular filter for 420kV SF6 Circuit Breaker
Corona rings (1 No of each type) for 420 kV Circuit Breaker
Relays, Power contactors, SFU, limit switches, push buttons, timers
&MCB etc. (1 No of each type) for 420kV Circuit Breaker
Pressure switches for 420kV SF6 pneumatic operated Circuit Breaker

0.01

33

7000001131
7000001131
7000001131
7000001131
7000001131
7000001131

SET

0.01

35

7000001131
7000001131

360
370

1000006920 MANDATORY SPARES


1000013056 MANDATORY SPARES

SET
SET

1
1

0.01

7000001131
7000001131

380
390

1000013160 MANDATORY SPARES


1000004461 MANDATORY SPARES

EA
EA

1
1

0.01

7000001131
7000001131

400
410

1000004535 MANDATORY SPARES


1000000388 MANDATORY SPARES

EA
EA

1
1

0.01

40

Aux. Switch/contact assembly for 420kV SF6 Circuit Breaker


Rubber gasket, O rings and seals for SF6 gas (complete replacement
forone 420kV SF6 Circuit Breaker)
Grading capacitors (if applicable) for 420kV SF6 Circuit Breaker
420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120%
extended currentrating
420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)
One Complete Pole of Double BreakIsolator including support
Insulatorwith 1 E/s (excluding structure) withMotor operating
Mechanism for 420kV,3150A, 50kA main Isolator and E/S

41

7000001131

420

1000031541 MANDATORY SPARES

SET

0.01

42

7000001131

430

1000009568 MANDATORY SPARES

SET

0.01

43

7000001131
7000001131
7000001131

440
450
460

1000014562 MANDATORY SPARES


1000009963 MANDATORY SPARES
1000021261 MANDATORY SPARES

COPPER CONTACT FINGERS FOR FEMALE & MALE CONTACTS OF


420KV DOUBLEBREAK ISOLATOR
Open / Close contactor assembly, timers, key interlock push
buttonswitch & auxiliary switches for 420kV Isolator
Limit switch for 420kV Isolator
Corona shield rings for 420kV Isolator
Terminal pads & connectors for 420kV,3150A Double Break Isolator

SET
SET
EA

1
1
1

0.01

31
32

36
37
38
39

44
45

SPARES
SPARES
SPARES
SPARES
SPARES
SPARES

Unit

7000001131

30

Material Code

1
19

29

PR Line
Item No

Mode of Transaction
(Direct / Boughtout)^
11

0.01
0.01
0.01
0.01
0.01

0.01

0.01

0.01

0.01
0.01

Schedule-1/ Page 17 of 120

All Prices are in Indian Rupees.


SI. No.

1
46
47

PR No

PR Line
Item No
3

Material Code

Header Description

48

7000001131
7000001131
7000001131

470
480
490

1000020419 MANDATORY SPARES


1000020440 MANDATORY SPARES
1000015978 MANDATORY SPARES

49

7000001131

500

1000028496 MANDATORY SPARES

50

7000001131

510

1000004401 MANDATORY SPARES

II

Item Description

Unit

Qty.

Unit Ex-works
price
9

Total Ex-works
price

336kV Surge Arrester (1-phase)


Surge monitor (1-Phase)
Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV
prot.,software
NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND
FAULTLOCATOR,OV PROT., SOFTWARE
420 kV, 1 phase Bus Post Insulator (except for Line Traps)

EA
EA
SET

1
1
1

10 = 8 x 9
0.01
0.01

SET

0.01

EA

0.01

EXTN. of 400/220kV NP KUNTA Substation


7000001132

10

1000004489 400KV EQUIPMENTS

420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor

EA

0.01

7000001132

20

1000004461 400KV EQUIPMENTS

EA

24

0.01

7000001132

30

1000004483 400KV EQUIPMENTS

420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120%


extended currentrating
420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S

EA

24

0.01

40
50
60
70

1000004535 400KV
1000020419 400KV
1000004401 400KV
1000001671 220KV

420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)


336kV Surge Arrester (1-phase)
420 kV, 1 phase Bus Post Insulator (except for Line Traps)
245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure

EA
EA
EA
EA

12
12
28
4

0.01

7000001132
7000001132
7000001132
7000001132

7000001132

80

1000001681 220KV EQUIPMENTS

EA

12

0.01

7000001132

90

1000001673 220KV EQUIPMENTS

245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120%


extended currentrating
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S

EA

0.01

10

7000001132

100

1000001674 220KV EQUIPMENTS

245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S

EA

0.01

11

7000001132

110

1000001794 220KV EQUIPMENTS

EA

0.01

12
13

7000001132
7000001132
7000001132
7000001132

120
130
140
150

1000001772 220KV EQUIPMENTS


1000020417 220KV EQUIPMENTS
1000001695 220KV EQUIPMENTS
1000002165 C&R PANEL (WITH SAS)

EA
EA
EA
EA

12
12
48
8

0.01
0.01

7000001132
7000001132

160
170

1000003398 C&R PANEL (WITH SAS)


1000001170 C&R PANEL (WITH SAS)

EA
EA

4
4

0.01

7000001132
7000001132

180
190

1000001330 C&R PANEL (WITH SAS)


1000003408 SUBSTATION AUTOMATION

EA
EA

4
8

0.01

19
20

7000001132

200

1000001332 SUBSTATION AUTOMATION

EA

0.01

21

7000001132

210

1000003410 SUBSTATION AUTOMATION

EA

0.01

22

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

220
230
240
250
260
270

1000004289 PLCC
1000004400 PLCC
1000001567 PLCC
1000001694 PLCC
1000010014 PLCC
1000031245 PLCC

245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without


E/S
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
216kV Surge Arrester (1-phase)
245 kV, 1 phase Bus Post Insulator (except for Line Traps)
400kV Circuit Breaker Relay Panel with Auto Reclose (with
Automation)
400kV Line Protection Panel (with Automation)
220kV Circuit Breaker Relay Panel with Auto Reclose (with
Automation)
220kV Line Protection Panel (with Automation)
Complete Substation automation System for 400kV Main bay as
perTechnical Specification
Complete Substation automation System for 220kV bay as per
TechnicalSpecification
Complete Substation automation System for 400kV Tie bay as
perTechnical Specification
400kV,3150A,0.5mH , 50kA Line Trap
420 kV ,1 phase Bus Post Insulators for Line Traps
220kV, 1600A, 0.5mH, 40 kA Line Trap
245 kV ,1 phase Bus Post Insulators for Line Traps
Coupling device for PLCC
ANALOGUE CARRIER EQUIPMENT (FOR SPEECH+ PROTECTION) 40W

EA
EA
EA
EA
SET
EA

4
12
4
12
4
4

0.01

14
15
16
17
18

23
24
25
26
27

11

0.01

Mode of Transaction
(Direct / Boughtout)^

EQUIPMENTS
EQUIPMENTS
EQUIPMENTS
EQUIPMENTS

EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS

0.01
0.01
0.01

0.01
0.01

0.01

0.01

0.01
0.01
0.01
0.01
0.01

Schedule-1/ Page 18 of 120

All Prices are in Indian Rupees.


SI. No.

1
28
29

PR No

Header Description

Item Description

Qty.

Unit Ex-works
price
9

Total Ex-works
price

30

1000017887 PLCC EQIPMENTS


1000010638 PLCC EQIPMENTS
1000006284 AIR CONDITIONING SYSTEM

Protection Coupler (Analog)


Digital Protection Coupler
Air conditioning system for Switchyard Panel Room of 6m length

EA
EA
SET

4
4
4

31

7000001132

310

1000006285 AIR CONDITIONING SYSTEM

Air conditioning system for Switchyard Panel Room of 9m length

SET

0.01

32
33

7000001132
7000001132
7000001132

320
330
340

1000012022 FIRE PROTECTION SYSTEM


1000014547 ILLUMINATION SYSTEM
1000020262 ILLUMINATION SYSTEM

EA
EA
EA

6
6
2

0.01
0.01

350
360
370
380
390
400
410

1000014535 ILLUMINATION
1000014536 ILLUMINATION
1000014534 ILLUMINATION
1000021982 ILLUMINATION
1000013795 ILLUMINATION
1000013796 ILLUMINATION
1000020125 STRUCTURE

EA
EA
EA
EA
LS
LS
EA

50
25
10
10
4
2
4

0.01

41

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

4.5 kg CO2 type Portable Fire extinguisher


Lighting Panel type ACP-2 as per technical specification
Sub Lighting panel (outdoor) type SLP (Switchyard and Street
Lighting)
Lighting Fixture type-SF1 as per technical specification
Lighting Fixture type-SF2 as per technical specification
Lighting Fixture type SC as per technical specification
Street Lighting pole type A1 as per technical specification.
Illumination System for switchyard panel room of 6 m length
Illumination System for switchyard panel room of 9 m length
Fabrication, galvanising and supply of Standard 400 kV Tower
TCincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

42

7000001132

420

1000020129 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Tower


TGincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

43

7000001132

430

1000020130 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Tower


THincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

44

7000001132

440

1000020132 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Tower


TJincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

45

7000001132

450

1000020146 STRUCTURE

Fabrication, galvanising and supply of Std 400 kV Tower TTT


includingnuts, bolts, all type of washers, packplates, step bolts and
gussetplates excluding foundation bolts

EA

0.01

46

7000001132

460

1000020148 STRUCTURE

Fabrication, galvanising and supply of Std 400 kV Tower TVV


includingnuts, bolts, all type of washers, packplates, step bolts and
gussetplates excluding foundation bolts

EA

0.01

47

7000001132

470

1000020118 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Gantry


G1including nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

12

0.01

48

7000001132

480

1000020119 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Gantry


G2including nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

18

0.01

49

7000001132

490

1000020098 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CBincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

50

7000001132

500

1000020099 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CCincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

51

7000001132

510

1000020100 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CDincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

36
37
38
39
40

SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM

Unit

280
290
300

35

Material Code

7000001132
7000001132
7000001132

34

PR Line
Item No

10 = 8 x 9
0.01
0.01

Mode of Transaction
(Direct / Boughtout)^
11

0.01

0.01

0.01
0.01
0.01
0.01
0.01
0.01

Schedule-1/ Page 19 of 120

All Prices are in Indian Rupees.


SI. No.

PR No

PR Line
Item No
3

Material Code

Header Description

Item Description

Unit

Qty.

Unit Ex-works
price
9

Total Ex-works
price

1
52

7000001132

520

1000020105 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CTCincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

10 = 8 x 9
0.01

53

7000001132

530

1000020110 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CTHincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

54

7000001132

540

1000020109 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CTGincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

55

7000001132

550

1000020086 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Gantry


B1including nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

56

7000001132

560

1000020088 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Gantry


BG1including nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

57

7000001132

570

1000020091 STRUCTURE

Fabrication, galvanising and supply of Std LM (50m) includingnuts,


bolts, all type of washers, packplates, step bolts and gussetplates
excluding foundation bolts

EA

0.01

58

7000001132

580

1000020192 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates,
step boltsand gusset plates excluding foundationbolts

EA

24

0.01

59

7000001132

590

1000020194 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers,
packplates,step bolts and gusset plates excludingfoundation bolts

EA

24

0.01

60

7000001132

600

1000020193 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 400kV CVT including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA

12

0.01

61

7000001132

690

1000020197 STRUCTURE

Fabrication, galvanising and supply of Std Pipe Structure - 400 kV


WTincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

62

7000001132

610

1000020195 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,1-Phase, SA including nuts, bolts,all type of washers, packplates,
stepbolts and gusset plates excludingfoundation bolts

EA

12

0.01

63
64

7000001132
7000001132

620
630

1000017567 STRUCTURE
1000020187 STRUCTURE

Standard Pipe Structure for 400kV BPI (excluding wave trap)


Fabrication, galvanising and supply of Standard Pipe Structure 220kV CT including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA
EA

28
12

0.01
0.01

65

7000001132

640

1000020188 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 220kV CVT including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA

12

0.01

66

7000001132

650

1000020189 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 220kV ISOLATOR including nuts, bolts, all type of washers,
packplates,step bolts and gusset plates excluding foundation bolts

EA

16

0.01

67

7000001132

700

1000020191 STRUCTURE

Fabrication, galvanising and supply of Std Pipe Structure - 220 kV


WTincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

Mode of Transaction
(Direct / Boughtout)^
11

Schedule-1/ Page 20 of 120

All Prices are in Indian Rupees.


SI. No.

1
68

PR No

Header Description

Item Description

Qty.

Unit Ex-works
price
9

Total Ex-works
price

1000020190 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 220kV SA including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA

12

7000001132
7000001132

670
680

1000017562 STRUCTURE
1000017565 STRUCTURE

Standard Pipe Structure for 220kV BPI (excluding wave trap)


Standard Pipe Structure for 220kV High BPI (excluding wave trap)

EA
EA

36
12

0.01

70
71

7000001132

710

1000012370 STRUCTURE

EA

208

0.01

72

7000001132

720

1000012369 STRUCTURE

EA

176

0.01

73

7000001132

730

1000012368 STRUCTURE

EA

76

0.01

74

7000001132

740

1000012366 STRUCTURE

EA

1872

0.01

75

7000001132
7000001132

1290
750

EA
SET

8
4

0.01

76
77

7000001132

760

1000011324 ERECTION HARDWARE

SET

0.01

78

7000001132

770

1000011326 ERECTION HARDWARE

SET

0.01

79

7000001132

780

1000011319 ERECTION HARDWARE

SET

0.01

80

7000001132

790

1000011261 ERECTION HARDWARE

SET

0.01

81

7000001132

800

1000011257 ERECTION HARDWARE

Fabrication, galvanising and supply of 63mm dia foundation


boltsincluding nuts, checknuts, washers and packplates
Fabrication, galvanising and supply of 56mm dia foundation
boltsincluding nuts, checknuts, washers and packplates
Fabrication, galvanising and supply of 40mm dia foundation
boltsincluding nuts, checknuts, washers and packplates.
Fabrication, galvanising and supply of 28mm dia foundation
boltsincluding nuts, checknuts, washers and packplates.
PTZ Camera for Video Monitoring System
Erection Hardware for 400kV I type layout-Line bay as per
technicalspecification
Erection Hardware for 400kV I type layout-Re-oriented Line bay as
pertechnical specification
Erection Hardware for 400kV I type layout-Spare bay of half dia as
pertechnical specification
Erection Hardware for 400kV I type layout-Bus Work (For two
diameters)as per technical specification
Erection Hardware for 220kV layout (Double Main and
TransferScheme)-Line Bay as per technical specification
Erection Hardware for 220kV layout (Double Main and
TransferScheme)-Bus work (three Bay) as per technical specification

SET

0.01

82

7000001132
7000001132

810
830

1000009250 POWER & CONTROL CABLE


1000000443 POWER & CONTROL CABLE

M
LS

1000
1

0.01

83
84

7000001132

840

1000000442 POWER & CONTROL CABLE

LS

0.01

85

7000001132

850

1000004488 MANDATORY SPARES

EA

0.01

86

7000001132

860

1000013056 MANDATORY SPARES

SET

0.01

87
88

870
880
890
900
910

1000021861 MANDATORY
1000009197 MANDATORY
1000015549 MANDATORY
1000009860 MANDATORY
1000018381 MANDATORY

SET
EA
EA
SET
SET

1
1
1
1
1

0.01
0.01

91

7000001132
7000001132
7000001132
7000001132
7000001132

92

7000001132

920

1000017844 MANDATORY SPARES

Rubber gasket, O rings and seals for SF6 gas (complete replacement
forone 420kV SF6 Circuit Breaker)
Trip coil with resistor for 420kV SF6 Circuit Breaker
Closing coil with resistor for 420kV SF6 Circuit Breaker
Molecular filter for 420kV SF6 Circuit Breaker
Corona rings (1 No of each type) for 420 kV Circuit Breaker
Relays, Power contactors, SFU, limit switches, push buttons, timers
&MCB etc. (1 No of each type) for 420kV Circuit Breaker
Pressure switches for 420kV SF6 pneumatic operated Circuit Breaker

SET

0.01

93

7000001132
7000001132

930
940

1000006920 MANDATORY SPARES


1000004461 MANDATORY SPARES

SET
EA

1
1

95

7000001132

950

1000004535 MANDATORY SPARES

Aux. Switch/contact assembly for 420kV SF6 Circuit Breaker


420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120%
extended currentrating
420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)

0.01

94

EA

0.01

90

1000017401 VISUAL MONITORING SYSTEM


1000011322 ERECTION HARDWARE

SPARES
SPARES
SPARES
SPARES
SPARES

Unit

660

89

Material Code

7000001132

69

PR Line
Item No

HF Cable 75 ohms for PLCC


1.1kV grade Power Cables (PVCinsulated)along
withlugs,glands,straight joints &accessories,etc.
1.1kV grade Control Cables (PVCinsulated) along
withlugs,glands,straight joints &accessories,etc.
One Pole of 420kV, 315 A, 50kA SF6circuit breaker with PIR
includinggrading capacitor (if applicable),Polecolumn interrupter,
with drivingmechanism and Marshaling Box butwithout support
structure.

10 = 8 x 9
0.01

Mode of Transaction
(Direct / Boughtout)^
11

0.01

0.01

0.01

0.01
0.01
0.01

0.01

Schedule-1/ Page 21 of 120

All Prices are in Indian Rupees.


SI. No.

PR No

Header Description

Item Description

Qty.

Unit Ex-works
price
9

Total Ex-works
price

960

1000000388 MANDATORY SPARES

One Complete Pole of Double BreakIsolator including support


Insulatorwith 1 E/s (excluding structure) withMotor operating
Mechanism for 420kV,3150A, 50kA main Isolator and E/S

EA

10 = 8 x 9
0.01

97

7000001132

970

1000031541 MANDATORY SPARES

SET

0.01

98

7000001132

980

1000009568 MANDATORY SPARES

SET

0.01

99

990
1000
1010
1020

1000014562 MANDATORY
1000009963 MANDATORY
1000020419 MANDATORY
1000001669 MANDATORY

SET
SET
EA
EA

1
1
1
1

0.01

102

7000001132
7000001132
7000001132
7000001132

COPPER CONTACT FINGERS FOR FEMALE & MALE CONTACTS OF


420KV DOUBLEBREAK ISOLATOR
Open / Close contactor assembly, timers, key interlock push
buttonswitch & auxiliary switches for 420kV Isolator
Limit switch for 420kV Isolator
Corona shield rings for 420kV Isolator
336kV Surge Arrester (1-phase)
One complete pole of 245kV, 1600A,40kACB including pole column,
interrupter,operating mechanism and Marshalling Boxbut without
support structure

103

7000001132

1030

1000013064 MANDATORY SPARES

SET

0.01

104

1040
1050
1060
1070
1080

1000021853 MANDATORY
1000009186 MANDATORY
1000015547 MANDATORY
1000028467 MANDATORY
1000018387 MANDATORY

EA
EA
EA
EA
SET

1
1
1
1
1

0.01

108

7000001132
7000001132
7000001132
7000001132
7000001132

Orings, gaskets and seals for operating mechanism for 245kV


SF6Circuit Breaker
Trip coil with resistor for 245kV Circuit Breaker
Closing coil with resistor for 245kV Circuit Breaker
Molecular filter for 245kV SF6 Circuit Breaker
CORONA RING FOR 245KV SF6 CIRCUIT BREAKER
Relays, Power contactors, SFU, limit switches, push buttons, timers
&MCB etc. (1 No of each type) for 245kV SF6 Circuit Breaker

109

7000001132

1090

1000017839 MANDATORY SPARES

Pressure Switches (1 no each type) for 245 kV SF6 Circuit Breaker

SET

0.01

110

7000001132
7000001132

1100
1110

1000006919 MANDATORY SPARES


1000001681 MANDATORY SPARES

SET
EA

1
1

0.01

7000001132
7000001132
7000001132

1120
1130
1140

1000001772 MANDATORY SPARES


1000020417 MANDATORY SPARES
1000032410 MANDATORY SPARES

EA
EA
EA

1
1
1

0.01

113
114

Aux. Switch assembly for 245kV, SF6 Circuit Breaker


245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120%
extended currentrating
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
216kV Surge Arrester (1-phase)
ONE COMPLETE POLE OF 245KV, 1600A, ISOLATOR WITH 1 E/S
EARTH SWITCHESWITH SUPPORT INSULATOR EXCLUDING STRUCTURE
AND MOTOR OPERATINGMECHANISM (MOM)

115

7000001132

1150

1000009794 MANDATORY SPARES

SET

0.01

116

7000001132

1160

1000009567 MANDATORY SPARES

SET

0.01

117

1170
1180
1190

1000014561 MANDATORY SPARES


1000030543 MANDATORY SPARES
1000015978 MANDATORY SPARES

SET
EA
SET

1
1
1

0.01

119

7000001132
7000001132
7000001132

120

7000001132

1200

1000028496 MANDATORY SPARES

SET

0.01

121

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

1210
1220
1230
1240
1250
1260
1270
1280

1000017773 MANDATORY
1000007634 MANDATORY
1000007627 MANDATORY
1000011151 MANDATORY
1000009029 MANDATORY
1000009028 MANDATORY
1000004401 MANDATORY
1000001695 MANDATORY

Copper contact fingers for female & male contacts of 245kV


DoubleBreak Isolator
Open / Close contactor assembly, timers, key interlock push
buttonswitch & auxiliary switches for 245kV Isolator
Limit switch for 245kV Isolator
Corona shield rings for 245 kV, 250A, 40 KA, 1 E/S isolator
Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV
prot.,software
NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND
FAULTLOCATOR,OV PROT., SOFTWARE
Power Supply module of each type for B/B Protection
Bay Unit module for Bus Bar Protection
Bay control unit (IED) of each type
Ethernet switch of each type
Set of Cards/prints for carrier terminal
Set of Cards/prints for Protection coupler
420 kV, 1 phase Bus Post Insulator (except for Line Traps)
245 kV, 1 phase Bus Post Insulator (except for Line Traps)

SET
EA
EA
SET
SET
SET
EA
EA

1
1
1
1
1
1
1
2

0.01

106
107

111
112

118

122
123
124
125
126
127
128

SPARES
SPARES
SPARES
SPARES

SPARES
SPARES
SPARES
SPARES
SPARES

SPARES
SPARES
SPARES
SPARES
SPARES
SPARES
SPARES
SPARES

Unit

7000001132

105

Material Code

1
96

100
101

PR Line
Item No

Mode of Transaction
(Direct / Boughtout)^
11

0.01
0.01
0.01

0.01
0.01
0.01
0.01

0.01

0.01
0.01

0.01
0.01

0.01
0.01
0.01
0.01
0.01
0.01
0.01
Schedule-1/ Page 22 of 120

All Prices are in Indian Rupees.


SI. No.

PR No

PR Line
Item No

Material Code

Header Description

Item Description

Unit

Qty.

Unit Ex-works
price

Total Ex-works
price

Mode of Transaction
(Direct / Boughtout)^

10 = 8 x 9

11

EA

0.01

SET

0.01

EA
EA

1
1

0.01

SET
SET
EA
SET
SET

1
1
1
1
1

0.01

EA
SET

1
1

0.01

EA
SET
EA
EA
EA
EA

1
1
1
1
1
1

0.01

SPARES INSULATING OIL TO BE HANDED OVER TO OWNER AFTER


COMMISSIONING

KL

10

0.01

III

ICT-4 AT NP KUNTA SS (500 MVA)

7000001130

740

1000004798 TRANSFORMER

7000001130

750

1000013986 TRANSFORMER

7000001130
7000001130

760
770

1000016764 TRANSFORMER
1000025219 TRANSFORMER

7000001130
7000001130
7000001130
7000001130
7000001130

780
800
810
820
830

1000025543 TRANSFORMER
1000016676 MANDATORY SPARES
1000009731 MANDATORY SPARES
1000028279 MANDATORY SPARES
1000007922 MANDATORY SPARES

7000001130
7000001130

840
850

1000028280 MANDATORY SPARES


1000020080 MANDATORY SPARES

17

7000001130
7000001130
7000001130
7000001130
7000001130
7000001130

860
870
880
890
900
910

1000006712 MANDATORY
1000016694 MANDATORY
1000004455 MANDATORY
1000001658 MANDATORY
1000004920 MANDATORY
1000002051 MANDATORY

18

7000001130

920

1000032089 MANDATORY SPARES

4
5
6
7
8
9
10
11
12
13
14
15
16

IV

SPARES
SPARES
SPARES
SPARES
SPARES
SPARES

500MVA, 400KV/220/33 KV, 3-phase Autotransformer excluding


insulatingoil
Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase
Autotransformer
On line Dissolved Gas(Multigas) & Moisture analyser
On line insulating oil drying system (Cartridge type) (As per
technicalspecification)
Set of Hand Tools With Tool Box as per Technical Specification
Oil cooler pump with motor for 400kV Transformer
Cooler fan with motor for 400kV Transformer
Local and Remote WTI with sensing device and contact
Buchholz Relay (Main Tank) complete with float and contacts
forTransformer
Magnetic Oil Level Gauge
Starters, contactors, switches, relays, lamps etc for Electrical
controlpanels, (One no. of each type) for Transformer
Analog Remote Tap Position Indicator
Oil flow indicator for 400kV T/F with flow switch
420kV, 2500A Bushing with metal partsand gaskets
245kV, 1600A Bushing with metal partsand gaskets
52kV, 3150A Bushing with metal parts andgaskets
36kV, 1000A Bushing with metal parts andgaskets for Transformer

0.01

0.01
0.01
0.01
0.01

0.01

0.01
0.01
0.01
0.01
0.01

4 Nos. 220kV bays at NP Kunta SS

7000001130

10

1000004489 400KV EQUIPMENTS

420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor

EA

0.01

7000001130

20

1000004461 400KV EQUIPMENTS

EA

0.01

7000001130

30

1000004483 400KV EQUIPMENTS

420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120%


extended currentrating
420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S

EA

0.01

7000001130

40

1000004426 400KV EQUIPMENTS

420kV, 2000A, 50 KA, Isolator (3-phase)(Double Break) with one E/S

EA

0.01

50
60
70

1000020419 400KV EQUIPMENTS


1000009711 400KV EQUIPMENTS
1000001671 220KV EQUIPMENTS

336kV Surge Arrester (1-phase)


Controlled switching device for 420 kV, 3 phase circuit breaker
245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure

EA
SET
EA

3
2
5

0.01

7000001130
7000001130
7000001130

7000001130

80

1000001681 220KV EQUIPMENTS

EA

15

0.01

7000001130

90

1000001673 220KV EQUIPMENTS

245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120%


extended currentrating
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S

EA

0.01

10

7000001130

100

1000001674 220KV EQUIPMENTS

245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S

EA

0.01

11

7000001130

110

1000001794 220KV EQUIPMENTS

EA

10

0.01

12

7000001130
7000001130

120
130

1000001772 220KV EQUIPMENTS


1000020417 220KV EQUIPMENTS

245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without


E/S
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
216kV Surge Arrester (1-phase)

EA
EA

12
15

0.01

13

0.01
0.01

0.01
Schedule-1/ Page 23 of 120

All Prices are in Indian Rupees.


SI. No.

PR No

Header Description

7000001130
7000001130

140
150

1000001695 220KV EQUIPMENTS


1000002163 C&R PANEL (WITH SAS)

16

7000001130

160

1000004274 C&R PANEL (WITH SAS)

17

7000001130

170

1000001170 C&R PANEL (WITH SAS)

18

7000001130

180

1000001168 C&R PANEL (WITH SAS)

19

7000001130
7000001130

190
200

1000001330 C&R PANEL (WITH SAS)


1000001332 SUBSTATION AUTOMATION

7000001130
7000001130
7000001130

210
220
230

1000001567 PLCC EQIPMENTS


1000001694 PLCC EQIPMENTS
1000006284 AIR CONDITIONING SYSTEM

25

7000001130
7000001130

240
250

1000012022 FIRE PROTECTION SYSTEM


1000012069 FIRE PROTECTION SYSTEM

26

7000001130

260

1000020262 ILLUMINATION SYSTEM

27
28
30

7000001130
7000001130
7000001130
7000001130

270
280
290
300

1000014535 ILLUMINATION SYSTEM


1000014536 ILLUMINATION SYSTEM
1000013795 ILLUMINATION SYSTEM
1000020097 STRUCTURE

31

7000001130

310

32

7000001130

33

Item Description

Qty.

Unit Ex-works
price
9

Total Ex-works
price

57
1

EA

0.01

EA

0.01

EA

0.01

EA
EA

4
5

0.01

EA
EA
SET

4
12
1

0.01

4.5 kg CO2 type Portable Fire extinguisher


HVW spray system, Hydrant system and complete U/G & O/G piping
andaccessories etc. out side the pump house for 500MVA ,
400KV/220/33kV, 3-phase Autotransformer

EA
SET

1
1

0.01

Sub Lighting panel (outdoor) type SLP (Switchyard and Street


Lighting)
Lighting Fixture type-SF1 as per technical specification
Lighting Fixture type-SF2 as per technical specification
Illumination System for switchyard panel room of 6 m length
Fabrication, galvanising and supply of Standard 220 kV Tower
CAincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

EA
EA
LS
EA

5
10
1
2

0.01
0.01

1000020099 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CCincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

320

1000020100 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CDincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

7000001130

330

1000020103 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CTAincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

34

7000001130

340

1000020104 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CTBincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

35

7000001130

350

1000020109 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower


CTGincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

36

7000001130

360

1000020086 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Gantry


B1including nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

37

7000001130

370

1000020088 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Gantry


BG1including nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

22
23
24

29

Unit

EA
EA

21

Material Code

1
14
15

20

PR Line
Item No

245 kV, 1 phase Bus Post Insulator (except for Line Traps)
400kV Circuit Breaker Relay Panel without Auto Reclose
(withAutomation)
400kV Transformer Protection Panel (For both HV & MV side)(withAutomation)
220kV Circuit Breaker Relay Panel with Auto Reclose (with
Automation)
220kV Circuit Breaker Relay Panel without Auto Reclose
(withAutomation)
220kV Line Protection Panel (with Automation)
Complete Substation automation System for 220kV bay as per
TechnicalSpecification
220kV, 1600A, 0.5mH, 40 kA Line Trap
245 kV ,1 phase Bus Post Insulators for Line Traps
Air conditioning system for Switchyard Panel Room of 6m length

10 = 8 x 9
0.01
0.01

Mode of Transaction
(Direct / Boughtout)^
11

0.01

0.01
0.01

0.01

0.01
0.01

Schedule-1/ Page 24 of 120

All Prices are in Indian Rupees.


SI. No.

PR No

PR Line
Item No
3

Material Code

Header Description

Item Description

Unit

Qty.

Unit Ex-works
price
9

Total Ex-works
price

1
38

7000001130

380

1000020192 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates,
step boltsand gusset plates excluding foundationbolts

EA

10 = 8 x 9
0.01

39

7000001130

390

1000020194 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers,
packplates,step bolts and gusset plates excludingfoundation bolts

EA

0.01

40

7000001130

400

1000020195 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400


kV,1-Phase, SA including nuts, bolts,all type of washers, packplates,
stepbolts and gusset plates excludingfoundation bolts

EA

0.01

41

7000001130

410

1000020187 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 220kV CT including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA

15

0.01

42

7000001130

420

1000020188 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 220kV CVT including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA

12

0.01

43

7000001130

430

1000020189 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 220kV ISOLATOR including nuts, bolts, all type of washers,
packplates,step bolts and gusset plates excluding foundation bolts

EA

20

0.01

44

7000001130

440

1000020191 STRUCTURE

Fabrication, galvanising and supply of Std Pipe Structure - 220 kV


WTincluding nuts, bolts, all type of washers, packplates, step bolts
andgusset plates excluding foundation bolts

EA

0.01

45

7000001130

450

1000020190 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure 220kV SA including nuts, bolts, all type of washers, packplates,
stepbolts and gusset plates excluding foundation bolts

EA

15

0.01

46

7000001130
7000001130

460
470

1000017562 STRUCTURE
1000017565 STRUCTURE

Standard Pipe Structure for 220kV BPI (excluding wave trap)


Standard Pipe Structure for 220kV High BPI (excluding wave trap)

EA
EA

42
15

0.01

47
48

7000001130

480

1000012369 STRUCTURE

EA

28

0.01

49

7000001130

490

1000012368 STRUCTURE

EA

48

0.01

50

7000001130

500

1000012366 STRUCTURE

EA

296

0.01

51

7000001130

510

1000031542 ERECTION HARDWARE

Fabrication, galvanising and supply of 56mm dia foundation


boltsincluding nuts, checknuts, washers and packplates
Fabrication, galvanising and supply of 40mm dia foundation
boltsincluding nuts, checknuts, washers and packplates.
Fabrication, galvanising and supply of 28mm dia foundation
boltsincluding nuts, checknuts, washers and packplates.
ERECTION HARDWARE FOR 400KV I TYPE LAYOUT-ANY FEEDER EXTN.
ONEXISTING HALF DIA (FOR ICT BAY) (INCLUDING ALL
REQUIREDINTERCONNECTIONS FOR THE TRANSFORMER AREA). AS
PER TECHNICALSPECIFICATION

SET

0.01

52

7000001130

520

1000011261 ERECTION HARDWARE

SET

0.01

53

7000001130

530

1000011257 ERECTION HARDWARE

Erection Hardware for 220kV layout (Double Main and


TransferScheme)-Line Bay as per technical specification
Erection Hardware for 220kV layout (Double Main and
TransferScheme)-Bus work (three Bay) as per technical specification

SET

0.01

54

7000001130

540

1000011264 ERECTION HARDWARE

SET

0.01

55

7000001130

550

1000017401 VISUAL MONITORING SYSTEM

Erection Hardware for 220kV layout (Double Main and


TransferScheme)-Transformer Bay as per technical specification
PTZ Camera for Video Monitoring System

EA

0.01

Mode of Transaction
(Direct / Boughtout)^
11

0.01

Schedule-1/ Page 25 of 120

All Prices are in Indian Rupees.


SI. No.

PR No

PR Line
Item No

Header Description

1
56

7000001130

570

1000000443 POWER & CONTROL CABLE

57

7000001130

580

1000000442 POWER & CONTROL CABLE

58

7000001130
7000001130

590
600

1000021791 MANDATORY SPARES


1000018532 MANDATORY SPARES

59

Material Code

Item Description

1.1kV grade Power Cables (PVCinsulated)along


withlugs,glands,straight joints &accessories,etc.
1.1kV grade Control Cables (PVCinsulated) along
withlugs,glands,straight joints &accessories,etc.
Transformer differential protection relay
Restricted earthfault relay type with non-linear resistor
andassociated software in case of numerical relay

Unit

Qty.

Unit Ex-works
price
9

LS

10 = 8 x 9
0.01

LS

0.01

EA
EA

1
1

0.01

Total Ex-Works Price Direct

Mode of Transaction
(Direct / Boughtout)^
11

0.01

Total Ex-Works Price Bought Out

2.55

Total Ex-Works Price

2.55

Total Type Test charges as per Schedule-7


Total Ex-works Price including Type Test charges
Note

Total Ex-works
price

2.55

1. Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished
items (to be identified in the Contract), which shall be dispatched directly from the sub-vendors works to the Employers site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to
be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.

2.

If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under Direct transaction by the bidder, then the taxes and duties on such items shall be paid/reimbursed by
POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding
taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the
rates prevailing on date of Bid opening.

3.

EA means each

Date

Place

-Printed Name :
Designation :

Schedule-1/ Page 26 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Con
& 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP K
of 220kV line bays) under Transmission system for Ultra Mega Solar Park in Ananta
iii)Extension of 400/220kV NP Kunta Substation including supply of 1x500MVA, 400/22
Transmission system for Ultra Mega Solar Park in Anantapur Distt, A
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidders Name and Address (Sole Bidder) :

To:

Contract Services
Name

Power Grid Corpo

Address

"Saudamini", Plot
Sector-29,

Gurgaon (Haryana

Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charge

SI. No.

Item Description

Unit

Qty.

Unit Exworks price

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509
Schedule-1/ Page 27 of 120

SI. No.

Item Description

Unit

Qty.

Unit Exworks price

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509

Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Total Ex-Works Price Direct


Total Ex-Works Price Bought Out

Schedule-1/ Page 28 of 120

SI. No.

Item Description

Unit

Qty.

Unit Exworks price

Total Ex-Works Price


Total Type Test charges as per Schedule-7
Total Ex-works Price including Type Test charges

Note

: Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the tra
and the Employer and octroi/entry tax as applicable for destination site/state on all
out finished items (to be identified in the Contract), which shall be dispatched direct
the Employers site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales
bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be

Date

: --

Place

Printed Name

Designation

Schedule-1/ Page 29 of 120

Schedule - 1

400kV Tuticorin substation under Connectivity with Kundankulam 3


ystem ii)Extension of 400/220kV NP Kunta Substation (with 4 nos.
m for Ultra Mega Solar Park in Anantapur distt, AP-Part-B and
ncluding supply of 1x500MVA, 400/220kV Autotransformer under
Mega Solar Park in Anantapur Distt, AP-Part-C.
ES AND PRICES : EX-WORKS PRICES)

Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001

to be supplied, including Type Test Charges for Tests to be conducted.


All Prices are in Indian Rupees.
Mode of
Transaction
Total Ex-works price
(Direct /
Bought-out)
6=4x5

Err:509 Err:509
Err:509

Err:509 Err:509
Err:509

Err:509 Err:509
Err:509

Err:509 Err:509
Err:509 Err:509

Schedule-1/ Page 30 of 120

All Prices are in Indian Rupees.


Mode of
Transaction
Total Ex-works price
(Direct /
Bought-out)
6=4x5

7
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509

Err:509 Err:509

Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509

Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
Err:509 Err:509

Err:509 Err:509
Err:509 Err:509
Err:509 Err:509
0.00 Direct
0.00

Schedule-1/ Page 31 of 120

All Prices are in Indian Rupees.


Mode of
Transaction
Total Ex-works price
(Direct /
Bought-out)
6=4x5

7
0.00
0.00
0.00

/'VAT and other taxes payable on the transaction between the Contractor
applicable for destination site/state on all items of supply including boughtContract), which shall be dispatched directly from the sub-vendors works to
arately in Schedule-5. Excise Duty, Sales tax and other levies for all the
EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.

Schedule-1/ Page 32 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Schedule - 2
REV-02
Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Connectivity with Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP Kunta Substation (with
4 nos. of 220kV line bays) under Transmission system for Ultra Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotransformer
under Transmission system for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.
(SCHEDULE OF RATES AND PRICES)
Bidders Name and Address (Sole Bidder) :
Name
Address

To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001

:
:

Local Transportation, Insurance and other Incidental Services


SI. No.

I
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

PR Line Item
No

Material Code

Header Description

Item Description

Unit

Quantity

420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor


420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended
currentrating
420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S
420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)
336kV Surge Arrester (1-phase)
420 kV, 1 phase Bus Post Insulator (except for Line Traps)
400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation)

EA
EA

2
6

0.01
0.01

EA
EA
EA
EA
EA

4
6
6
6
2

0.01
0.01
0.01
0.01
0.01

400kV Line Protection Panel (with Automation)

EA

0.01

400kV,3150A,1.0mH , 50kA Line Trap


420 kV ,1 phase Bus Post Insulators for Line Traps
Lighting Panel type ACP-2 as per technical specification
Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting)
Lighting Fixture type-SF1 as per technical specification
Lighting Fixture type-SF2 as per technical specification
Lighting Fixture type SC as per technical specification
Street Lighting pole type A1 as per technical specification.
Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase,
CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset
plates excluding foundationbolts

EA
EA
EA
EA
EA
EA
EA
EA
EA

4
12
1
2
20
20
5
5
6

0.01
0.01
0.01
0.01
0.01
0.01

10 = 8 x 9

400KV KUDANKULAM BAY EXTN. AT TUTICORIN


7000001131
7000001131

10
20

1000004489 420KV EQUIPMENTS


1000004461 420KV EQUIPMENTS

7000001131
7000001131
7000001131
7000001131
7000001131

30
40
50
60
70

7000001131

80

7000001131
7000001131
7000001131
7000001131
7000001131
7000001131
7000001131
7000001131
7000001131

90
100
110
120
130
140
150
160
170

1000004483 420KV EQUIPMENTS


1000004535 420KV EQUIPMENTS
1000020419 420KV EQUIPMENTS
1000004401 420KV EQUIPMENTS
1000002165 CONTROL & RELAY PANEL (WITH
AUTOMATION)
1000003398 CONTROL & RELAY PANEL (WITH
AUTOMATION)
1000000003 PLCC SYSTEM
1000004400 PLCC SYSTEM
1000014547 ILLUMINATION SYSTEM
1000020262 ILLUMINATION SYSTEM
1000014535 ILLUMINATION SYSTEM
1000014536 ILLUMINATION SYSTEM
1000014534 ILLUMINATION SYSTEM
1000021982 ILLUMINATION SYSTEM
1000020192 STRUCTURE

7000001131

180

1000020193 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 400kV CVT


including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA

0.01

7000001131

190

1000020194 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase,


ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and
gusset plates excludingfoundation bolts

EA

0.01

17

18

19

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

PR No

0.01
0.01
0.01

Schedule-2/ Page 33 of 120

SI. No.

PR No

PR Line Item
No
3

Material Code

Header Description

23
24
25
26

33
34
35
36
37
38
39

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase,


SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset
plates excludingfoundation bolts

EA

0.01

7000001131
7000001131

210
220

1000017567 STRUCTURE
1000020197 STRUCTURE

Standard Pipe Structure for 400kV BPI (excluding wave trap)


Fabrication, galvanising and supply of Std Pipe Structure - 400 kV WTincluding
nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA
EA

6
4

0.01
0.01

7000001131

230

1000012366 STRUCTURE

EA

264

0.01

7000001131

240

1000011320 ERECTION HARDWARE

SET

0.01

7000001131

260

1000000442 POWER & CONTROL CABLE

LS

0.01

7000001131

270

1000000443 POWER & CONTROL CABLE

LS

0.01

7000001131

280

1000004488 MANDATORY SPARES

Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts,


checknuts, washers and packplates.
Erection Hardware for 400kV I type layout-Any feeder Extn. on existinghalf dia.
as per technical specification
1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints
&accessories,etc.
1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints
&accessories,etc.
One Pole of 420kV, 315 A, 50kA SF6circuit breaker with PIR includinggrading
capacitor (if applicable),Polecolumn interrupter, with drivingmechanism and
Marshaling Box butwithout support structure.

EA

0.01

7000001131
7000001131
7000001131
7000001131
7000001131
7000001131

290
300
310
320
330
340

1000021861 MANDATORY
1000009197 MANDATORY
1000021444 MANDATORY
1000015549 MANDATORY
1000009860 MANDATORY
1000018381 MANDATORY

SET
EA
EA
EA
SET
SET

1
1
1
1
1
1

0.01
0.01
0.01
0.01
0.01
0.01

7000001131
7000001131
7000001131

350
360
370

1000017844 MANDATORY SPARES


1000006920 MANDATORY SPARES
1000013056 MANDATORY SPARES

SET
SET
SET

1
1
1

0.01
0.01
0.01

7000001131
7000001131

380
390

1000013160 MANDATORY SPARES


1000004461 MANDATORY SPARES

EA
EA

1
1

0.01

7000001131
7000001131

400
410

1000004535 MANDATORY SPARES


1000000388 MANDATORY SPARES

Trip coil with resistor for 420kV SF6 Circuit Breaker


Closing coil with resistor for 420kV SF6 Circuit Breaker
Terminal pad for 420kV SF6 Circuit Breaker
Molecular filter for 420kV SF6 Circuit Breaker
Corona rings (1 No of each type) for 420 kV Circuit Breaker
Relays, Power contactors, SFU, limit switches, push buttons, timers &MCB etc.
(1 No of each type) for 420kV Circuit Breaker
Pressure switches for 420kV SF6 pneumatic operated Circuit Breaker
Aux. Switch/contact assembly for 420kV SF6 Circuit Breaker
Rubber gasket, O rings and seals for SF6 gas (complete replacement forone
420kV SF6 Circuit Breaker)
Grading capacitors (if applicable) for 420kV SF6 Circuit Breaker
420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended
currentrating
420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)
One Complete Pole of Double BreakIsolator including support Insulatorwith 1 E/s
(excluding structure) withMotor operating Mechanism for 420kV,3150A, 50kA
main Isolator and E/S

EA
EA

1
1

0.01
0.01

7000001131

420

1000031541 MANDATORY SPARES

SET

0.01

7000001131

430

1000009568 MANDATORY SPARES

SET

0.01

7000001131
7000001131
7000001131
7000001131
7000001131
7000001131

440
450
460
470
480
490

1000014562 MANDATORY
1000009963 MANDATORY
1000021261 MANDATORY
1000020419 MANDATORY
1000020440 MANDATORY
1000015978 MANDATORY

COPPER CONTACT FINGERS FOR FEMALE & MALE CONTACTS OF 420KV


DOUBLEBREAK ISOLATOR
Open / Close contactor assembly, timers, key interlock push buttonswitch &
auxiliary switches for 420kV Isolator
Limit switch for 420kV Isolator
Corona shield rings for 420kV Isolator
Terminal pads & connectors for 420kV,3150A Double Break Isolator
336kV Surge Arrester (1-phase)
Surge monitor (1-Phase)
Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV
prot.,software

SET
SET
EA
EA
EA
SET

1
1
1
1
1
1

0.01
0.01
0.01
0.01
0.01
0.01

SPARES
SPARES
SPARES
SPARES
SPARES
SPARES

40
41
42
43
44
45
46
47
48

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

1000020195 STRUCTURE

27
28
29
30
31
32

Quantity

200

22

SPARES
SPARES
SPARES
SPARES
SPARES
SPARES

Unit

7000001131
20
21

Item Description

10 = 8 x 9

0.01

Schedule-2/ Page 34 of 120

SI. No.

49
50

II
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

PR No

PR Line Item
No
3

Material Code

Header Description

7000001131

500

1000028496 MANDATORY SPARES

7000001131

510

1000004401 MANDATORY SPARES

Item Description

Unit

Quantity

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND FAULTLOCATOR,OV


PROT., SOFTWARE
420 kV, 1 phase Bus Post Insulator (except for Line Traps)

SET

10 = 8 x 9
0.01

EA

0.01

420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor


420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended
currentrating
420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S
420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)
336kV Surge Arrester (1-phase)
420 kV, 1 phase Bus Post Insulator (except for Line Traps)
245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure
245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended
currentrating
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S
245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without E/S
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
216kV Surge Arrester (1-phase)
245 kV, 1 phase Bus Post Insulator (except for Line Traps)
400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation)
400kV Line Protection Panel (with Automation)
220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation)
220kV Line Protection Panel (with Automation)
Complete Substation automation System for 400kV Main bay as perTechnical
Specification
Complete Substation automation System for 220kV bay as per
TechnicalSpecification
Complete Substation automation System for 400kV Tie bay as perTechnical
Specification
400kV,3150A,0.5mH , 50kA Line Trap
420 kV ,1 phase Bus Post Insulators for Line Traps
220kV, 1600A, 0.5mH, 40 kA Line Trap
245 kV ,1 phase Bus Post Insulators for Line Traps
Coupling device for PLCC
ANALOGUE CARRIER EQUIPMENT (FOR SPEECH+ PROTECTION) 40W

EA
EA

8
24

0.01
0.01

EA
EA
EA
EA
EA
EA

24
12
12
28
4
12

0.01
0.01
0.01
0.01
0.01
0.01

EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA

4
4
8
12
12
48
8
4
4
4
8

0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01

EA

0.01

EA

0.01

EA
EA
EA
EA
SET
EA

4
12
4
12
4
4

0.01
0.01

Protection Coupler (Analog)


Digital Protection Coupler
Air conditioning system for Switchyard Panel Room of 6m length
Air conditioning system for Switchyard Panel Room of 9m length
4.5 kg CO2 type Portable Fire extinguisher
Lighting Panel type ACP-2 as per technical specification
Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting)
Lighting Fixture type-SF1 as per technical specification

EA
EA
SET
SET
EA
EA
EA
EA

4
4
4
2
6
6
2
50

0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01

EXTN. of 400/220kV NP KUNTA Substation


7000001132
7000001132

10
20

1000004489 400KV EQUIPMENTS


1000004461 400KV EQUIPMENTS

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

30
40
50
60
70
80

1000004483 400KV
1000004535 400KV
1000020419 400KV
1000004401 400KV
1000001671 220KV
1000001681 220KV

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

90
100
110
120
130
140
150
160
170
180
190

1000001673 220KV EQUIPMENTS


1000001674 220KV EQUIPMENTS
1000001794 220KV EQUIPMENTS
1000001772 220KV EQUIPMENTS
1000020417 220KV EQUIPMENTS
1000001695 220KV EQUIPMENTS
1000002165 C&R PANEL (WITH SAS)
1000003398 C&R PANEL (WITH SAS)
1000001170 C&R PANEL (WITH SAS)
1000001330 C&R PANEL (WITH SAS)
1000003408 SUBSTATION AUTOMATION

7000001132

200

1000001332 SUBSTATION AUTOMATION

7000001132

210

1000003410 SUBSTATION AUTOMATION

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

220
230
240
250
260
270

1000004289 PLCC
1000004400 PLCC
1000001567 PLCC
1000001694 PLCC
1000010014 PLCC
1000031245 PLCC

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

280
290
300
310
320
330
340
350

1000017887 PLCC EQIPMENTS


1000010638 PLCC EQIPMENTS
1000006284 AIR CONDITIONING SYSTEM
1000006285 AIR CONDITIONING SYSTEM
1000012022 FIRE PROTECTION SYSTEM
1000014547 ILLUMINATION SYSTEM
1000020262 ILLUMINATION SYSTEM
1000014535 ILLUMINATION SYSTEM

EQUIPMENTS
EQUIPMENTS
EQUIPMENTS
EQUIPMENTS
EQUIPMENTS
EQUIPMENTS

EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS

0.01
0.01
0.01
0.01

Schedule-2/ Page 35 of 120

SI. No.

36
37
38
39
40

PR No

PR Line Item
No
3

Material Code

Header Description

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

25
10
10
4
2
4

0.01
0.01
0.01
0.01
0.01
0.01

1000020129 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Tower TGincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

430

1000020130 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Tower THincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001132

440

1000020132 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Tower TJincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001132

450

1000020146 STRUCTURE

Fabrication, galvanising and supply of Std 400 kV Tower TTT includingnuts, bolts,
all type of washers, packplates, step bolts and gussetplates excluding
foundation bolts

EA

0.01

7000001132

460

1000020148 STRUCTURE

Fabrication, galvanising and supply of Std 400 kV Tower TVV includingnuts,


bolts, all type of washers, packplates, step bolts and gussetplates excluding
foundation bolts

EA

0.01

7000001132

470

1000020118 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Gantry G1including nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

12

0.01

7000001132

480

1000020119 STRUCTURE

Fabrication, galvanising and supply of Standard 400 kV Gantry G2including nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

18

0.01

7000001132

490

1000020098 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CBincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001132

500

1000020099 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CCincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001132

510

1000020100 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CDincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001132

520

1000020105 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CTCincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001132

530

1000020110 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CTHincluding


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

7000001132

540

1000020109 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CTGincluding


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

1000014536 ILLUMINATION
1000014534 ILLUMINATION
1000021982 ILLUMINATION
1000013795 ILLUMINATION
1000013796 ILLUMINATION
1000020125 STRUCTURE

7000001132

420

7000001132

41

42

43

44

45

46

47

48

49

50

51

52

53

54

Quantity

EA
EA
EA
LS
LS
EA

360
370
380
390
400
410

SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM

Unit

Lighting Fixture type-SF2 as per technical specification


Lighting Fixture type SC as per technical specification
Street Lighting pole type A1 as per technical specification.
Illumination System for switchyard panel room of 6 m length
Illumination System for switchyard panel room of 9 m length
Fabrication, galvanising and supply of Standard 400 kV Tower TCincluding nuts,
bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

Item Description

10 = 8 x 9

Schedule-2/ Page 36 of 120

SI. No.

PR No

PR Line Item
No
3

Material Code

Header Description

Fabrication, galvanising and supply of Standard 220 kV Gantry B1including nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001132

560

1000020088 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Gantry BG1including


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

7000001132

570

1000020091 STRUCTURE

Fabrication, galvanising and supply of Std LM (50m) includingnuts, bolts, all type
of washers, packplates, step bolts and gussetplates excluding foundation bolts

EA

0.01

7000001132

580

1000020192 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase,


CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset
plates excluding foundationbolts

EA

24

0.01

7000001132

590

1000020194 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase,


ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and
gusset plates excludingfoundation bolts

EA

24

0.01

7000001132

600

1000020193 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 400kV CVT


including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA

12

0.01

7000001132

690

1000020197 STRUCTURE

Fabrication, galvanising and supply of Std Pipe Structure - 400 kV WTincluding


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

7000001132

610

1000020195 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase,


SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset
plates excludingfoundation bolts

EA

12

0.01

7000001132
7000001132

620
630

1000017567 STRUCTURE
1000020187 STRUCTURE

Standard Pipe Structure for 400kV BPI (excluding wave trap)


Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT
including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA
EA

28
12

0.01
0.01

7000001132

640

1000020188 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CVT


including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA

12

0.01

7000001132

650

1000020189 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 220kV


ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and
gusset plates excluding foundation bolts

EA

16

0.01

7000001132

700

1000020191 STRUCTURE

Fabrication, galvanising and supply of Std Pipe Structure - 220 kV WTincluding


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

7000001132

660

1000020190 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA


including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA

12

0.01

7000001132
7000001132
7000001132

670
680
710

1000017562 STRUCTURE
1000017565 STRUCTURE
1000012370 STRUCTURE

EA
EA
EA

36
12
208

0.01
0.01
0.01

7000001132

720

1000012369 STRUCTURE

EA

176

0.01

7000001132

730

1000012368 STRUCTURE

Standard Pipe Structure for 220kV BPI (excluding wave trap)


Standard Pipe Structure for 220kV High BPI (excluding wave trap)
Fabrication, galvanising and supply of 63mm dia foundation boltsincluding nuts,
checknuts, washers and packplates
Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts,
checknuts, washers and packplates
Fabrication, galvanising and supply of 40mm dia foundation boltsincluding nuts,
checknuts, washers and packplates.

EA

76

0.01

58

59

60

61

62

64

65

66

67

68

72
73

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

1000020086 STRUCTURE

57

71

Quantity

550

56

69
70

Unit

7000001132
55

63

Item Description

10 = 8 x 9

Schedule-2/ Page 37 of 120

SI. No.

74
75
76
77
78
79
80
81
82
83
84

PR No

PR Line Item
No
3

Material Code

Header Description

87
88
89
90
91
92
93
94
95

98
99
100
101

Quantity

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

EA

1872

0.01

1000017401 VISUAL MONITORING SYSTEM

EA

0.01

750

1000011322 ERECTION HARDWARE

Erection Hardware for 400kV I type layout-Line bay as per technicalspecification

SET

0.01

7000001132

760

1000011324 ERECTION HARDWARE

SET

0.01

7000001132

770

1000011326 ERECTION HARDWARE

SET

0.01

7000001132

780

1000011319 ERECTION HARDWARE

SET

0.01

7000001132

790

1000011261 ERECTION HARDWARE

SET

0.01

7000001132

800

1000011257 ERECTION HARDWARE

SET

0.01

7000001132
7000001132

810
830

1000009250 POWER & CONTROL CABLE


1000000443 POWER & CONTROL CABLE

M
LS

1000
1

0.01
0.01

7000001132

840

1000000442 POWER & CONTROL CABLE

LS

0.01

7000001132

850

1000004488 MANDATORY SPARES

Erection Hardware for 400kV I type layout-Re-oriented Line bay as pertechnical


specification
Erection Hardware for 400kV I type layout-Spare bay of half dia as pertechnical
specification
Erection Hardware for 400kV I type layout-Bus Work (For two diameters)as per
technical specification
Erection Hardware for 220kV layout (Double Main and TransferScheme)-Line Bay
as per technical specification
Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus
work (three Bay) as per technical specification
HF Cable 75 ohms for PLCC
1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints
&accessories,etc.
1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints
&accessories,etc.
One Pole of 420kV, 315 A, 50kA SF6circuit breaker with PIR includinggrading
capacitor (if applicable),Polecolumn interrupter, with drivingmechanism and
Marshaling Box butwithout support structure.

EA

0.01

7000001132

860

1000013056 MANDATORY SPARES

SET

0.01

7000001132
7000001132
7000001132
7000001132
7000001132

870
880
890
900
910

1000021861 MANDATORY
1000009197 MANDATORY
1000015549 MANDATORY
1000009860 MANDATORY
1000018381 MANDATORY

SET
EA
EA
SET
SET

1
1
1
1
1

0.01
0.01
0.01

7000001132
7000001132
7000001132

920
930
940

1000017844 MANDATORY SPARES


1000006920 MANDATORY SPARES
1000004461 MANDATORY SPARES

SET
SET
EA

1
1
1

0.01
0.01
0.01

7000001132
7000001132

950
960

1000004535 MANDATORY SPARES


1000000388 MANDATORY SPARES

Rubber gasket, O rings and seals for SF6 gas (complete replacement forone
420kV SF6 Circuit Breaker)
Trip coil with resistor for 420kV SF6 Circuit Breaker
Closing coil with resistor for 420kV SF6 Circuit Breaker
Molecular filter for 420kV SF6 Circuit Breaker
Corona rings (1 No of each type) for 420 kV Circuit Breaker
Relays, Power contactors, SFU, limit switches, push buttons, timers &MCB etc.
(1 No of each type) for 420kV Circuit Breaker
Pressure switches for 420kV SF6 pneumatic operated Circuit Breaker
Aux. Switch/contact assembly for 420kV SF6 Circuit Breaker
420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended
currentrating
420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase)
One Complete Pole of Double BreakIsolator including support Insulatorwith 1 E/s
(excluding structure) withMotor operating Mechanism for 420kV,3150A, 50kA
main Isolator and E/S

EA
EA

1
1

0.01
0.01

7000001132

970

1000031541 MANDATORY SPARES

SET

0.01

7000001132

980

1000009568 MANDATORY SPARES

SET

0.01

7000001132
7000001132
7000001132

990
1000
1010

1000014562 MANDATORY SPARES


1000009963 MANDATORY SPARES
1000020419 MANDATORY SPARES

COPPER CONTACT FINGERS FOR FEMALE & MALE CONTACTS OF 420KV


DOUBLEBREAK ISOLATOR
Open / Close contactor assembly, timers, key interlock push buttonswitch &
auxiliary switches for 420kV Isolator
Limit switch for 420kV Isolator
Corona shield rings for 420kV Isolator
336kV Surge Arrester (1-phase)

SET
SET
EA

1
1
1

0.01
0.01
0.01

740

7000001132

1290

7000001132

1000012366 STRUCTURE

SPARES
SPARES
SPARES
SPARES
SPARES

96
97

Unit

Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts,


checknuts, washers and packplates.
PTZ Camera for Video Monitoring System

7000001132

85
86

Item Description

10 = 8 x 9

0.01
0.01

Schedule-2/ Page 38 of 120

SI. No.

PR No

PR Line Item
No
3

Material Code

Header Description

104
105
106
107
108
109
110
111
112
113

116
117
118
119
120
121
122
123
124
125
126
127
128

III
1
2
3
4
5

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

1000001669 MANDATORY SPARES

One complete pole of 245kV, 1600A,40kACB including pole column,


interrupter,operating mechanism and Marshalling Boxbut without support
structure

EA

0.01

7000001132

1030

1000013064 MANDATORY SPARES

SET

0.01

7000001132
7000001132
7000001132
7000001132
7000001132

1040
1050
1060
1070
1080

1000021853 MANDATORY
1000009186 MANDATORY
1000015547 MANDATORY
1000028467 MANDATORY
1000018387 MANDATORY

EA
EA
EA
EA
SET

1
1
1
1
1

0.01
0.01
0.01
0.01
0.01

7000001132
7000001132
7000001132

1090
1100
1110

1000017839 MANDATORY SPARES


1000006919 MANDATORY SPARES
1000001681 MANDATORY SPARES

SET
SET
EA

1
1
1

0.01
0.01
0.01

7000001132
7000001132
7000001132

1120
1130
1140

1000001772 MANDATORY SPARES


1000020417 MANDATORY SPARES
1000032410 MANDATORY SPARES

Orings, gaskets and seals for operating mechanism for 245kV SF6Circuit
Breaker
Trip coil with resistor for 245kV Circuit Breaker
Closing coil with resistor for 245kV Circuit Breaker
Molecular filter for 245kV SF6 Circuit Breaker
CORONA RING FOR 245KV SF6 CIRCUIT BREAKER
Relays, Power contactors, SFU, limit switches, push buttons, timers &MCB etc.
(1 No of each type) for 245kV SF6 Circuit Breaker
Pressure Switches (1 no each type) for 245 kV SF6 Circuit Breaker
Aux. Switch assembly for 245kV, SF6 Circuit Breaker
245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended
currentrating
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
216kV Surge Arrester (1-phase)
ONE COMPLETE POLE OF 245KV, 1600A, ISOLATOR WITH 1 E/S EARTH
SWITCHESWITH SUPPORT INSULATOR EXCLUDING STRUCTURE AND MOTOR
OPERATINGMECHANISM (MOM)

EA
EA
EA

1
1
1

0.01
0.01
0.01

7000001132

1150

1000009794 MANDATORY SPARES

SET

0.01

7000001132

1160

1000009567 MANDATORY SPARES

SET

0.01

7000001132
7000001132
7000001132

1170
1180
1190

1000014561 MANDATORY SPARES


1000030543 MANDATORY SPARES
1000015978 MANDATORY SPARES

SET
EA
SET

1
1
1

0.01
0.01
0.01

7000001132

1200

1000028496 MANDATORY SPARES

SET

0.01

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

1210
1220
1230
1240
1250
1260
1270
1280

1000017773 MANDATORY
1000007634 MANDATORY
1000007627 MANDATORY
1000011151 MANDATORY
1000009029 MANDATORY
1000009028 MANDATORY
1000004401 MANDATORY
1000001695 MANDATORY

Copper contact fingers for female & male contacts of 245kV DoubleBreak
Isolator
Open / Close contactor assembly, timers, key interlock push buttonswitch &
auxiliary switches for 245kV Isolator
Limit switch for 245kV Isolator
Corona shield rings for 245 kV, 250A, 40 KA, 1 E/S isolator
Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV
prot.,software
NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND FAULTLOCATOR,OV
PROT., SOFTWARE
Power Supply module of each type for B/B Protection
Bay Unit module for Bus Bar Protection
Bay control unit (IED) of each type
Ethernet switch of each type
Set of Cards/prints for carrier terminal
Set of Cards/prints for Protection coupler
420 kV, 1 phase Bus Post Insulator (except for Line Traps)
245 kV, 1 phase Bus Post Insulator (except for Line Traps)

SET
EA
EA
SET
SET
SET
EA
EA

1
1
1
1
1
1
1
2

0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01

114
115

Quantity

1020

SPARES
SPARES
SPARES
SPARES
SPARES

SPARES
SPARES
SPARES
SPARES
SPARES
SPARES
SPARES
SPARES

Unit

7000001132
102
103

Item Description

10 = 8 x 9

ICT-4 AT NP KUNTA SS (500 MVA)


7000001130

740

1000004798 TRANSFORMER

500MVA, 400KV/220/33 KV, 3-phase Autotransformer excluding insulatingoil

EA

0.01

7000001130
7000001130
7000001130

750
760
770

1000013986 TRANSFORMER
1000016764 TRANSFORMER
1000025219 TRANSFORMER

SET
EA
EA

1
1
1

0.01
0.01
0.01

7000001130

780

1000025543 TRANSFORMER

Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase Autotransformer


On line Dissolved Gas(Multigas) & Moisture analyser
On line insulating oil drying system (Cartridge type) (As per
technicalspecification)
Set of Hand Tools With Tool Box as per Technical Specification

SET

0.01
Schedule-2/ Page 39 of 120

SI. No.

6
7
8
9
10
11
12
13
14
15
16
17
18

IV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

PR No

PR Line Item
No
3

Material Code

Header Description

7000001130
7000001130
7000001130
7000001130

800
810
820
830

1000016676 MANDATORY
1000009731 MANDATORY
1000028279 MANDATORY
1000007922 MANDATORY

SPARES
SPARES
SPARES
SPARES

7000001130
7000001130

840
850

1000028280 MANDATORY SPARES


1000020080 MANDATORY SPARES

7000001130
7000001130
7000001130
7000001130
7000001130
7000001130
7000001130

860
870
880
890
900
910
920

1000006712 MANDATORY
1000016694 MANDATORY
1000004455 MANDATORY
1000001658 MANDATORY
1000004920 MANDATORY
1000002051 MANDATORY
1000032089 MANDATORY

SPARES
SPARES
SPARES
SPARES
SPARES
SPARES
SPARES

Item Description

Unit

Quantity

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

Oil cooler pump with motor for 400kV Transformer


Cooler fan with motor for 400kV Transformer
Local and Remote WTI with sensing device and contact
Buchholz Relay (Main Tank) complete with float and contacts forTransformer

SET
EA
SET
SET

1
1
1
1

10 = 8 x 9
0.01
0.01
0.01
0.01

Magnetic Oil Level Gauge


Starters, contactors, switches, relays, lamps etc for Electrical controlpanels,
(One no. of each type) for Transformer
Analog Remote Tap Position Indicator
Oil flow indicator for 400kV T/F with flow switch
420kV, 2500A Bushing with metal partsand gaskets
245kV, 1600A Bushing with metal partsand gaskets
52kV, 3150A Bushing with metal parts andgaskets
36kV, 1000A Bushing with metal parts andgaskets for Transformer
SPARES INSULATING OIL TO BE HANDED OVER TO OWNER AFTER
COMMISSIONING

EA
SET

1
1

0.01
0.01

EA
SET
EA
EA
EA
EA
KL

1
1
1
1
1
1
10

0.01
0.01
0.01
0.01
0.01
0.01
0.01

EA
EA

1
3

0.01
0.01

EA
EA
EA
SET
EA
EA

1
1
3
2
5
15

0.01
0.01
0.01
0.01
0.01
0.01

EA
EA
EA
EA
EA
EA
EA

5
5
10
12
15
57
1

0.01
0.01
0.01
0.01
0.01
0.01
0.01

4 Nos. 220kV bays at NP Kunta SS


7000001130
7000001130

10
20

1000004489 400KV EQUIPMENTS


1000004461 400KV EQUIPMENTS

7000001130
7000001130
7000001130
7000001130
7000001130
7000001130

30
40
50
60
70
80

1000004483 400KV
1000004426 400KV
1000020419 400KV
1000009711 400KV
1000001671 220KV
1000001681 220KV

7000001130
7000001130
7000001130
7000001130
7000001130
7000001130
7000001130

90
100
110
120
130
140
150

1000001673 220KV EQUIPMENTS


1000001674 220KV EQUIPMENTS
1000001794 220KV EQUIPMENTS
1000001772 220KV EQUIPMENTS
1000020417 220KV EQUIPMENTS
1000001695 220KV EQUIPMENTS
1000002163 C&R PANEL (WITH SAS)

420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor


420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended
currentrating
420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S
420kV, 2000A, 50 KA, Isolator (3-phase)(Double Break) with one E/S
336kV Surge Arrester (1-phase)
Controlled switching device for 420 kV, 3 phase circuit breaker
245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure
245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended
currentrating
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S
245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without E/S
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
216kV Surge Arrester (1-phase)
245 kV, 1 phase Bus Post Insulator (except for Line Traps)
400kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation)

7000001130

160

1000004274 C&R PANEL (WITH SAS)

400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation)

EA

0.01

7000001130
7000001130

170
180

1000001170 C&R PANEL (WITH SAS)


1000001168 C&R PANEL (WITH SAS)

220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation)
220kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation)

EA
EA

4
1

0.01
0.01

7000001130
7000001130

190
200

1000001330 C&R PANEL (WITH SAS)


1000001332 SUBSTATION AUTOMATION

EA
EA

4
5

0.01
0.01

7000001130
7000001130
7000001130

210
220
230

1000001567 PLCC EQIPMENTS


1000001694 PLCC EQIPMENTS
1000006284 AIR CONDITIONING SYSTEM

220kV Line Protection Panel (with Automation)


Complete Substation automation System for 220kV bay as per
TechnicalSpecification
220kV, 1600A, 0.5mH, 40 kA Line Trap
245 kV ,1 phase Bus Post Insulators for Line Traps
Air conditioning system for Switchyard Panel Room of 6m length

EA
EA
SET

4
12
1

0.01
0.01
0.01

EQUIPMENTS
EQUIPMENTS
EQUIPMENTS
EQUIPMENTS
EQUIPMENTS
EQUIPMENTS

Schedule-2/ Page 40 of 120

SI. No.

24

PR No

PR Line Item
No
3

Material Code

Header Description

Quantity

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

240
250

1000012022 FIRE PROTECTION SYSTEM


1000012069 FIRE PROTECTION SYSTEM

4.5 kg CO2 type Portable Fire extinguisher


HVW spray system, Hydrant system and complete U/G & O/G piping
andaccessories etc. out side the pump house for 500MVA , 400KV/220/33kV, 3phase Autotransformer

EA
SET

1
1

0.01
0.01

7000001130
7000001130
7000001130
7000001130
7000001130

260
270
280
290
300

1000020262 ILLUMINATION
1000014535 ILLUMINATION
1000014536 ILLUMINATION
1000013795 ILLUMINATION
1000020097 STRUCTURE

Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting)
Lighting Fixture type-SF1 as per technical specification
Lighting Fixture type-SF2 as per technical specification
Illumination System for switchyard panel room of 6 m length
Fabrication, galvanising and supply of Standard 220 kV Tower CAincluding nuts,
bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA
EA
EA
LS
EA

2
5
10
1
2

0.01
0.01
0.01
0.01
0.01

7000001130

310

1000020099 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CCincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001130

320

1000020100 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CDincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001130

330

1000020103 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CTAincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001130

340

1000020104 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CTBincluding nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001130

350

1000020109 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Tower CTGincluding


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

7000001130

360

1000020086 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Gantry B1including nuts,


bolts, all type of washers, packplates, step bolts andgusset plates excluding
foundation bolts

EA

0.01

7000001130

370

1000020088 STRUCTURE

Fabrication, galvanising and supply of Standard 220 kV Gantry BG1including


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

7000001130

380

1000020192 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase,


CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset
plates excluding foundationbolts

EA

0.01

7000001130

390

1000020194 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase,


ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and
gusset plates excludingfoundation bolts

EA

0.01

7000001130

400

1000020195 STRUCTURE

Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase,


SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset
plates excludingfoundation bolts

EA

0.01

7000001130

410

1000020187 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT


including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA

15

0.01

7000001130

420

1000020188 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CVT


including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA

12

0.01

30

31

32

33

34

35

36

37

38

39

40

41

42

Unit

7000001130
7000001130

25
26
27
28
29

Item Description

SYSTEM
SYSTEM
SYSTEM
SYSTEM

10 = 8 x 9

Schedule-2/ Page 41 of 120

SI. No.

PR No

PR Line Item
No
3

Material Code

Header Description

49
50

Fabrication, galvanising and supply of Standard Pipe Structure - 220kV


ISOLATOR including nuts, bolts, all type of washers, packplates,step bolts and
gusset plates excluding foundation bolts

EA

20

0.01

7000001130

440

1000020191 STRUCTURE

Fabrication, galvanising and supply of Std Pipe Structure - 220 kV WTincluding


nuts, bolts, all type of washers, packplates, step bolts andgusset plates
excluding foundation bolts

EA

0.01

7000001130

450

1000020190 STRUCTURE

Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA


including nuts, bolts, all type of washers, packplates, stepbolts and gusset
plates excluding foundation bolts

EA

15

0.01

7000001130
7000001130
7000001130

460
470
480

1000017562 STRUCTURE
1000017565 STRUCTURE
1000012369 STRUCTURE

EA
EA
EA

42
15
28

0.01
0.01
0.01

7000001130

490

1000012368 STRUCTURE

EA

48

0.01

7000001130

500

1000012366 STRUCTURE

EA

296

0.01

7000001130

510

1000031542 ERECTION HARDWARE

Standard Pipe Structure for 220kV BPI (excluding wave trap)


Standard Pipe Structure for 220kV High BPI (excluding wave trap)
Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts,
checknuts, washers and packplates
Fabrication, galvanising and supply of 40mm dia foundation boltsincluding nuts,
checknuts, washers and packplates.
Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts,
checknuts, washers and packplates.
ERECTION HARDWARE FOR 400KV I TYPE LAYOUT-ANY FEEDER EXTN.
ONEXISTING HALF DIA (FOR ICT BAY) (INCLUDING ALL
REQUIREDINTERCONNECTIONS FOR THE TRANSFORMER AREA). AS PER
TECHNICALSPECIFICATION

SET

0.01

7000001130

520

1000011261 ERECTION HARDWARE

SET

0.01

7000001130

530

1000011257 ERECTION HARDWARE

SET

0.01

7000001130

540

1000011264 ERECTION HARDWARE

SET

0.01

7000001130

550

1000017401 VISUAL MONITORING SYSTEM

Erection Hardware for 220kV layout (Double Main and TransferScheme)-Line Bay
as per technical specification
Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus
work (three Bay) as per technical specification
Erection Hardware for 220kV layout (Double Main and TransferScheme)Transformer Bay as per technical specification
PTZ Camera for Video Monitoring System

EA

0.01

7000001130

570

1000000443 POWER & CONTROL CABLE

LS

0.01

7000001130

580

1000000442 POWER & CONTROL CABLE

LS

0.01

7000001130
7000001130

590
600

1000021791 MANDATORY SPARES


1000018532 MANDATORY SPARES

1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints


&accessories,etc.
1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints
&accessories,etc.
Transformer differential protection relay
Restricted earthfault relay type with non-linear resistor andassociated software
in case of numerical relay

EA
EA

1
1

0.01
0.01

51

52
53
54
55
56
57
58
59

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

1000020189 STRUCTURE

45

48

Quantity

430

44

Unit

7000001130
43

46
47

Item Description

Total F&I Price

10 = 8 x 9

2.55

Note : 1.Bidders to Note that the item description under various schedules are through unique material ID for respective items under SAP ERP System and therefore, identical item description appears in schedule-1(Ex-works) & schedule-2(F&I). However,
the prices to be quoted in Price Schedule-2(F&I) shall be towards Local Transportation, Insurance and other Incidental Services only in line with clause ITB 11.4(b).

Date
:

2. EA means each
--

Schedule-2/ Page 42 of 120

SI. No.

1
Place
:

PR No

PR Line Item
No

Material Code

Header Description

Item Description

Unit

Quantity

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance
Insurance Charges
Charges

8
Printed Name
Designation

10 = 8 x 9

:
:

Schedule-2/ Page 43 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation


Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extens
Substation (with 4 nos. of 220kV line bays) under Transmission system for U
Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substat
1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Me
AP-Part-C.
(SCHEDULE OF RATES AND Distt,
PRICES
: FREIGHT & INSURANCE CH
Bidders Name and Address (Sole Bidder) :

Name

Address

SI. No.

Description

Unit

Quantity

I
Err:509

0.0
Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509

Schedule-2/ Page 44 of 120

SI. No.

Description

Unit

Quantity

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Total F&I Price

Date

: --

Place

Printed Name

Designation

Schedule-2/ Page 45 of 120

Schedule - 2 Dis

) Extension of 400kV Tuticorin substation under Connectivity with


Inter-state Transmission System ii)Extension of 400/220kV NP Kunta
ne bays) under Transmission system for Ultra Mega Solar Park in
Extension of 400/220kV NP Kunta Substation including supply of
er under Transmission system for Ultra Mega Solar Park in Anantapur
AP-Part-C.
ES AND Distt,
PRICES
: FREIGHT & INSURANCE CHARGES)
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
All Prices are in Indian Rupees.
Unit Freight &
Total Freight &
Insurance Charges Insurance Charges
5

6=4x5
Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Schedule-2/ Page 46 of 120

All Prices are in Indian Rupees.


Unit Freight &
Total Freight &
Insurance Charges Insurance Charges
5

6=4x5
Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Schedule-2/ Page 47 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Schedule - 3
REV-02
Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Connectivity with Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension of
400/220kV NP Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system for Ultra Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta
Substation including supply of 1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.
(SCHEDULE OF RATES AND PRICES )
Bidders Name and Address (Sole Bidder) :
Name

Address

"Saudamini", Plot No.-2


Sector-29,
Gurgaon (Haryana) - 122001

Installation Charges :
SI. No.
PR No

To:
Contract Services
Power Grid Corporation of India
Ltd.,

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

Total Erection
Charges

10

11

12 = 10 x 11

EA

0.01

EA

24

0.01

EA

24

0.01

EA

12

0.01

EA
EA
EA

12
28
4

0.01
0.01
0.01

EA

12

0.01

EA

0.01

EA

0.01

EA

0.01

EA

12

0.01

EA
EA

12
48

0.01
0.01

EA

0.01

EXTN. of 400/220kV NP KUNTA Substation

7000001132

1300

140

10 400KV EQUIPMENTS

7000001132

1300

140

20 400KV EQUIPMENTS

7000001132

1300

140

30 400KV EQUIPMENTS

7000001132

1300

140

40 400KV EQUIPMENTS

5
6
7

7000001132
7000001132
7000001132

1300
1300
1310

140
140
150

50 400KV EQUIPMENTS
60 400KV EQUIPMENTS
10 220KV EQUIPMENTS

7000001132

1310

150

20 220KV EQUIPMENTS

7000001132

1310

150

30 220KV EQUIPMENTS

10

7000001132

1310

150

40 220KV EQUIPMENTS

11

7000001132

1310

150

50 220KV EQUIPMENTS

12

7000001132

1310

150

60 220KV EQUIPMENTS

13
14

7000001132
7000001132

1310
1310

150
150

70 220KV EQUIPMENTS
80 220KV EQUIPMENTS

15

7000001132

1320

160

10 C&R PANEL (WITH SAS)

100001898 420kV, 3150A, 50kA Circuit Breaker(3-Phase) without


closing resistor(withsupport structure)
100000270 420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with
120% extended currentrating
100000307 420kV, 3150A, 50KA, Isolator (3-phase)(Double Break)
with one E/S
100000275 420 kV, 4400 pF Capacitive Voltage Transformer (1Phase)
100000328 336kV Surge Arrester (1-phase)
100000340 420 kV Bus Post Insulator (Except for wave traps)
100000435 245kV, 1600A, 40KA Circuit Breaker(3-Phase) with
support structure
100000443 245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with
120% extended currentrating
100000461 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator
with one E/S
100000462 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator
with two E/S
100000464 245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem
Isolator without E/S
100000448 245 kV, 4400pf Capacitive Voltage Transformer (1Phase)
100000484 216kV Surge Arrester (1-phase)
100001907 245 kV,1 phase Bus Post Insulator (except for Line
Traps)
100000728 400kV Circuit Breaker Relay Panel with Auto Reclose
(with Automation)

Schedule-3/ Page 48 of 120

Installation Charges :
SI. No.
PR No

PR Line
Item No

1
16
17

2
7000001132
7000001132

3
1320
1320

18
19

7000001132
7000001132

20

Activity
Header
4

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

Total Erection
Charges

9
EA
EA

10
4
4

11

EA
EA

4
8

0.01
0.01

EA

0.01

EA

0.01

EA
EA
EA
EA
EA
EA

4
12
4
12
4
4

0.01
0.01
0.01
0.01
0.01
0.01

EA
EA
SET

4
4
4

0.01
0.01
0.01

SET

0.01

EA

0.01

160
160

6
20 C&R PANEL (WITH SAS)
30 C&R PANEL (WITH SAS)

1320
1330

160
170

40 C&R PANEL (WITH SAS)


10 SUBSTATION AUTOMATION

7000001132

1330

170

20 SUBSTATION AUTOMATION

21

7000001132

1330

170

30 SUBSTATION AUTOMATION

22
23
24
25
26
27

7000001132
7000001132
7000001132
7000001132
7000001132
7000001132

1340
1340
1340
1340
1340
1340

180
180
180
180
180
180

10 PLCC
20 PLCC
30 PLCC
40 PLCC
50 PLCC
60 PLCC

28
29
30

7000001132
7000001132
7000001132

1340
1340
1350

180
180
190

70 PLCC EQIPMENTS
80 PLCC EQIPMENTS
10 AIR CONDITIONING SYSTEM

31

7000001132

1350

190

20 AIR CONDITIONING SYSTEM

32

7000001132

1360

200

10 FIRE PROTECTION SYSTEM

7
8
100000730 400kV Line Protection Panel (with Automation)
100000736 220kV Circuit Breaker Relay Panel with Auto Reclose
(with Automation)
100000738 220kV Line Protection Panel (with Automation)
100000771 Complete Substation automation System for 400kV
Main bay as per Technical Specification
100000772 Complete Substation automation System for 220kV bay
as per Technical Specification
100000777 Complete Substation automation System for 400kV Tie
bay as per Technical Specification
100000874 400kV,3150A,0.5mH , 50kA Line Trap
100000883 420 kV ,1 phase Bus Post Insulators for Line Traps
100000878 220kV, 1600A, 0.5mH, 40 kA Line Trap
100000884 245 kV ,1 phase Bus Post Insulators for Line Traps
100000886 Coupling device for PLCC
100000888 Carrier Equipment Analog type (for Speech+Data &
Speech+Protection)
100000890 Protection Coupler (Analog)
100000891 Digital Protection Coupler
100001882 Air conditioning system for Switchyard Panel Room of
6m length
100001881 Air conditioning system for Switchyard Panel Room of
9m length
100000975 4.5 kg CO2 type Portable Fire extinguisher

33

7000001132

1370

210

10 ILLUMINATION SYSTEM

100001021 Lighting Panel type ACP-2 as per technical specification

EA

0.01

34

7000001132

1370

210

20 ILLUMINATION SYSTEM

EA

0.01

35

7000001132

1370

210

30 ILLUMINATION SYSTEM

100001024 Sub Lighting panel (outdoor) type SLP (Switchyard and


Street Lighting)
100001041 Lighting Fixture type-SF1 as per technical specification

EA

50

0.01

36

7000001132

1370

210

40 ILLUMINATION SYSTEM

100001042 Lighting Fixture type-SF2 as per technical specification

EA

25

0.01

37

7000001132

1370

210

50 ILLUMINATION SYSTEM

100001037 Lighting Fixture type SC as per technical specification

EA

10

0.01

38

7000001132

1370

210

60 ILLUMINATION SYSTEM

EA

10

0.01

39

7000001132

1370

210

70 ILLUMINATION SYSTEM

100001060 Street Lighting pole type A1 as per technical


specification.
100001116 Illumination System for switchyard panel room of 6 m
length

SET

0.01

EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS
EQIPMENTS

12 = 10 x 11
0.01
0.01

Schedule-3/ Page 49 of 120

Installation Charges :
SI. No.
PR No

PR Line
Item No

1
40

2
7000001132

3
1370

41

7000001132

42

Activity
Header
4

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

Total Erection
Charges

7
8
100001115 Illumination System for switchyard panel room of 9 m
length
100002500 Color IP camera, with PAN, TILT and ZOOM facilities,
alongwith all required Items, Accessories, Line Interface
units, Fiber patchcords, Power supply units, Junction
Boxes, Cables, Fiber Optic Cables, etc., and including
Integration in existing Hardware andSoftware for
Augmentation of Visual Monitoring System as per
technical specification.

9
SET

10
2

11

SET

0.01

100000329 Erection Hardware for 400kV I type layout-Line bay as


per specification
100000332 Erection Hardware for 400kV I type layout-Re-oriented
Line bay as per specification
100000335 Erection Hardware for 400kV I type layout-Spare bay of
half dia as per specification
100000337 Erection Hardware for 400kV I type layout-Bus Work
(For two diameters)/bays as per specification

SET

0.01

SET

0.01

SET

0.01

SET

0.01

210

6
80 ILLUMINATION SYSTEM

1380

230

10 VISUAL MONITORING SYSTEM

7000001132

1390

240

10 ERECTION HARDWARE

43

7000001132

1390

240

20 ERECTION HARDWARE

44

7000001132

1390

240

30 ERECTION HARDWARE

45

7000001132

1390

240

40 ERECTION HARDWARE

46

7000001132

1390

240

50 ERECTION HARDWARE

100000485 Erection Hardware for 220kV layout (Double Main and


Transfer Scheme as per SLD)-Line Bay as per
specification

SET

0.01

47

7000001132

1390

240

60 ERECTION HARDWARE

100000491 Erection Hardware for 220kV layout (Double Main and


Transfer Scheme as per SLD)-Bus work (three Bay) as
per specification

SET

0.01

48

7000001132

1400

260

10 CIVIL WORKS

15700

0.01

7000001132

1400

260

20 CIVIL WORKS

100001324 Excavation in all types of soil and rock including


disposal
for allCement
leads and
lifts (PCC)
100001325 backfilling
Providing and
layingetc.
of Plain
Concrete

M3

49

M3

500

0.01

M3

200

0.01

M3

2500

0.01

100001328 Providing and laying Plain Cement Concrete 1:5:10 (1


cement : 5 sand : 10 brick aggregate)
100001329 Steel Reinforcement
100001331 Misc. Structural steel including rails, embedments,
edge protection angles, gratings etc. but excluding the
reinforcement steel andsteel for lattice and pipe
structures.

M3

3100

0.01

MT
MT

159
35

0.01
0.01

100001375 Stone spreading and antiweed treatment in switchyard


excluding PCC

M2

40700

0.01

50

7000001132

1400

260

30 CIVIL WORKS

51

7000001132

1400

260

40 CIVIL WORKS

52

7000001132

1400

260

50 CIVIL WORKS

53
54

7000001132
7000001132

1400
1400

260
260

60 CIVIL WORKS
70 CIVIL WORKS

55

7000001132

1400

260

80 CIVIL WORKS

(1:4:8)
100001326 Providing and laying of Plain Cement Concrete (PCC)
(1:2:4)
100001327 Providing and laying of Reinforced Cement Concrete
M25 mix including pre cast, shuttering, Grouting of
pockets & underpinning butexcluding steel
reinforcement

12 = 10 x 11
0.01

Schedule-3/ Page 50 of 120

Installation Charges :
SI. No.
PR No

PR Line
Item No

1
56

2
7000001132

3
1400

57

7000001132

58

Activity
Header
4

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

7
8
100001735 RCC culverts and cable trench crossings including
supplying and laying hume pipe 250mm dia of grade
(NP-3) excluding concrete as perspecification.

9
M

10
100

11

Total Erection
Charges
12 = 10 x 11
0.01

260

90 CIVIL WORKS

1400

260

100 CIVIL WORKS

100001736 RCC culverts and cable trench crossings including


supplying and laying hume pipe 300mm dia of grade
(NP-3) excluding concrete as perspecification.

40

0.01

7000001132

1400

260

110 CIVIL WORKS

100001737 RCC culverts and cable trench crossings including


supplying and laying hume pipe 450mm dia of grade
(NP-3) excluding concrete as perspecification.

40

0.01

59

7000001132

1400

260

120 CIVIL WORKS

100001720 Supplying, filling and compacting CNS material as per


specification under floors, foundations, roads, cable
trenches, drains etc inlayers not exceeding 200 mm
thickness

M3

1000

0.01

60

7000001132

1400

260

130 CIVIL WORKS

100001478 Cable Trench including all types of crossings, all


metallic works and sump pit including concrte and
reinforcement steel Section 2-2

400

0.01

61

7000001132

1400

260

140 CIVIL WORKS

100001479 Cable Trench including all types of crossings, all


metallic works and sump pit including concrte and
reinforcement steel Section 3-3

400

0.01

62

7000001132

1400

260

150 CIVIL WORKS

100001693 All civil works as per drawing and specification but


excluding excavation, PCC, RCC, reinforcement but
including finishing (internaland external) etc & all civil
works complete in all respect - 220 kV Switchyard Panel
Room

M2

63

0.01

63

7000001132

1400

260

160 CIVIL WORKS

100001692 All civil works as per drawing and specification but


excluding excavation, PCC, RCC, reinforcement but
including finishing (internaland external) etc & all civil
works complete in all respect - 400 kV Switchyard Panel
Room

M2

84

0.01

64

7000001132

1400

260

170 CIVIL WORKS

100001678 Erection of 63mm dia foundation bolts including nuts,


checknuts, washers and packplates.

EA

208

0.01

65

7000001132

1400

260

180 CIVIL WORKS

EA

176

0.01

66

7000001132

1400

260

190 CIVIL WORKS

EA

76

0.01

67

7000001132

1400

260

200 CIVIL WORKS

EA

1872

0.01

68

7000001132

1410

280

10 STRUCTURE

100001677 Erection of 56mm dia foundation bolts including nuts,


checknuts, washers and packplates
100001676 Erection of 40mm dia foundation bolts including nuts,
checknuts, washers and packplates.
100001674 Erection of 28mm dia foundation bolts including nuts,
checknuts, washers and packplates.
100001153 Erection of Std 400 kV Tower TC including nuts, bolts,
all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

Schedule-3/ Page 51 of 120

Installation Charges :
SI. No.
PR No

PR Line
Item No

1
69

2
7000001132

3
1410

70

7000001132

71

Activity
Header
4

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

7
8
100001157 Erection of Std 400 kV Tower TG including nuts, bolts,
all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

9
EA

10
1

11

Total Erection
Charges
12 = 10 x 11
0.01

280

20 STRUCTURE

1410

280

30 STRUCTURE

100001158 Erection of Std 400 kV Tower TH including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

7000001132

1410

280

40 STRUCTURE

100001160 Erection of Std 400 kV Tower TJ including nuts, bolts, all


type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

72

7000001132

1410

280

50 STRUCTURE

100001626 Erection of Std 400 kV Tower TTT including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

73

7000001132

1410

280

60 STRUCTURE

100001628 Erection of Std 400 kV Tower TVV including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

74

7000001132

1410

280

70 STRUCTURE

100001171 Erection of Std 400 kV Gantry G1 including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

12

0.01

75

7000001132

1410

280

80 STRUCTURE

100001172 Erection of Std 400 kV Gantry G2 including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

18

0.01

76

7000001132

1410

280

90 STRUCTURE

100001185 Erection of Std 220 kV Tower CB including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

77

7000001132

1410

280

100 STRUCTURE

100001187 Erection of Std 220 kV Tower CC including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

78

7000001132

1410

280

110 STRUCTURE

100001188 Erection of Std 220 kV Tower CD including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

79

7000001132

1410

280

120 STRUCTURE

100001193 Erection of Std 220 kV Tower CTC including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

80

7000001132

1410

280

130 STRUCTURE

100001199 Erection of Std 220 kV Tower CTH including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

81

7000001132

1410

280

140 STRUCTURE

100001198 Erection of Std 220 kV Tower CTG including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

82

7000001132

1410

280

150 STRUCTURE

100001204 Erection of Std 220 kV Gantry B1 including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

83

7000001132

1410

280

160 STRUCTURE

100001205 Erection of Std 220 kV Gantry BG1 including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

Schedule-3/ Page 52 of 120

Installation Charges :
SI. No.
PR No

PR Line
Item No

1
84

2
7000001132

3
1410

85

7000001132

86

Activity
Header
4

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

7
8
100001212 Erection of Pipe Structure - 400 kV 1-Phase CT
including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

9
EA

10
24

11

Total Erection
Charges
12 = 10 x 11
0.01

280

170 STRUCTURE

1410

280

180 STRUCTURE

100001213 Erection of Pipe Structure - 400 kV 1-Phase CVT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

12

0.01

7000001132

1410

280

190 STRUCTURE

100001214 Erection of Pipe Structure - 400 kV 3-Phase ISOLATOR


including nuts, bolts, all type of washers, packplates,
step bolts and gussetplates excluding foundation bolts

EA

24

0.01

87

7000001132

1410

280

200 STRUCTURE

100001215 Erection of Pipe Structure - 400 kV 1-Phase WT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

0.01

88

7000001132

1410

280

210 STRUCTURE

100001216 Erection of Pipe Structure - 400 kV 1-Phase SA including


nuts, bolts, all type of washers, packplates, step bolts
and gusset platesexcluding foundation bolts

EA

12

0.01

89

7000001132

1410

280

220 STRUCTURE

100001217 Erection of Pipe Structure - 400 kV, 1-Phase, BPI,


(Excluding Wave Trap), including nuts, bolts, all type
of washers,packplates, step bolts and gusset plates
excluding foundation bolts

EA

28

0.01

90

7000001132

1410

280

230 STRUCTURE

100001220 Erection of Pipe Structure - 220 kV 1-Phase CT including


nuts, bolts, all type of washers, packplates, step bolts
and gusset platesexcluding foundation bolts

EA

12

0.01

91

7000001132

1410

280

240 STRUCTURE

100001221 Erection of Pipe Structure - 220 kV 1-Phase CVT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

12

0.01

92

7000001132

1410

280

250 STRUCTURE

100001222 Erection of Pipe Structure - 220 kV 3-Phase ISOLATOR


including nuts, bolts, all type of washers, packplates,
step bolts and gussetplates excluding foundation bolts

EA

16

0.01

93

7000001132

1410

280

260 STRUCTURE

100001223 Erection of Pipe Structure - 220 kV 1-Phase WT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

0.01

94

7000001132

1410

280

270 STRUCTURE

100001224 Erection of Pipe Structure - 220 kV 1-Phase SA including


nuts, bolts, all type of washers, packplates, step bolts
and gusset platesexcluding foundation bolts

EA

12

0.01

Schedule-3/ Page 53 of 120

Installation Charges :
SI. No.
PR No

PR Line
Item No

1
95

2
7000001132

3
1410

96

7000001132

97

Activity
Header
4

PR Activity Activity Description


No
5

Unit

Quantity

Unit
Erection
Charges

7
8
100001225 Erection of Pipe Structure - 220 kV 1-Phase BPI
including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

9
EA

10
36

11

100001226 Standard Pipe Structure for 220kV High BPI (excluding


wave trap)
100001667 Erection of Std LM (50m) including nuts, bolts, all type
of washers, packplates, step bolts and gusset plates
excluding foundationbolts

EA

12

0.01

EA

0.01

100002181 1.1kV grade Power Cables (PVCinsulated)along


withlugs,glands,straight joints &accessories,etc.
100002182 1.1kV grade Control Cables (PVCinsulated) along
withlugs,glands,straight joints &accessories,etc.
100003517 HF CABLE FOR PLCC-75 OHM (KM)

LS

0.01

LS

0.01

KM

0.01

EA

0.01

EA

0.01

EA

0.01

EA

0.01

420KV

100001898 420kV, 3150A, 50kA Circuit Breaker(3-Phase) without


closing resistor(withsupport structure)
100000270 420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with
120% extended currentrating
100000307 420kV, 3150A, 50KA, Isolator (3-phase)(Double Break)
with one E/S
100000275 420 kV, 4400 pF Capacitive Voltage Transformer (1Phase)
100000328 336kV Surge Arrester (1-phase)

EA

0.01

420KV

100000340 420 kV Bus Post Insulator (Except for wave traps)

EA

0.01

C&R (WITH

EA

0.01

C&R (WITH

100000728 400kV Circuit Breaker Relay Panel with Auto Reclose


(with Automation)
100000730 400kV Line Protection Panel (with Automation)

EA

0.01

PLCC SYSTEM

100000873 400kV,3150A,1.0mH , 50kA Line Trap

EA

0.01

280

280 STRUCTURE

1410

280

290 STRUCTURE

7000001132

1410

280

300 STRUCTURE

98

7000001132

1420

300

10 POWER & CONTROL CABLES

99

7000001132

1420

300

30 POWER & CONTROL CABLES

100

7000001132

1420

300

40 POWER & CONTROL CABLES

II

Service Code

Description

Total Erection
Charges
12 = 10 x 11
0.01

400KV KUDANKULAM BAY EXTN. AT TUTICORIN

7000001131

520

100

7000001131

520

100

7000001131

520

100

7000001131

520

100

7000001131

520

100

7000001131

520

100

7000001131

530

110

7000001131

530

110

7000001131

540

120

10 INSTALLATIONEQUIPMENT
20 INSTALLATIONEQUIPMENT
30 INSTALLATIONEQUIPMENT
40 INSTALLATIONEQUIPMENT
50 INSTALLATIONEQUIPMENT
60 INSTALLATIONEQUIPMENT
10 INSTALLATIONAUTOMATION)
20 INSTALLATIONAUTOMATION)
10 INSTALLATION-

420KV

10

7000001131

540

120

20 INSTALLATION- PLCC SYSTEM

100000883 420 kV ,1 phase Bus Post Insulators for Line Traps

EA

12

0.01

11

7000001131

540

120

30 INSTALLATION- PLCC SYSTEM

SET

0.01

12

7000001131

550

130

EA

0.01

13

7000001131

550

130

10 INSTALLATION- ILLUMINATION
SYSTEM
20 INSTALLATION- ILLUMINATION
SYSTEM

100001492 Dismantling, transportation & re-erection of 400kV


PLCC
100001021 Lighting Panel type ACP-2 as per technical specification
100001024 Sub Lighting panel (outdoor) type SLP (Switchyard and
Street Lighting)

EA

0.01

420KV
420KV
420KV

Schedule-3/ Page 54 of 120

Installation Charges :
SI. No.
PR No

1
14

2
7000001131

15

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges
11

Total Erection
Charges

7
8
100001041 Lighting Fixture type-SF1 as per technical specification

9
EA

10
20

100001042 Lighting Fixture type-SF2 as per technical specification

EA

20

0.01

100001037 Lighting Fixture type SC as per technical specification

EA

0.01

100001060 Street Lighting pole type A1 as per technical


specification.
100001212 Erection of Pipe Structure - 400 kV 1-Phase CT
including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

0.01

140

6
30 INSTALLATION- ILLUMINATION
SYSTEM
40 INSTALLATION- ILLUMINATION
SYSTEM
50 INSTALLATION- ILLUMINATION
SYSTEM
60 INSTALLATION- ILLUMINATION
SYSTEM
10 INSTALLATION- STRUCTURE

EA

0.01

560

140

20 INSTALLATION- STRUCTURE

100001213 Erection of Pipe Structure - 400 kV 1-Phase CVT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

0.01

7000001131

560

140

30 INSTALLATION- STRUCTURE

100001214 Erection of Pipe Structure - 400 kV 3-Phase ISOLATOR


including nuts, bolts, all type of washers, packplates,
step bolts and gussetplates excluding foundation bolts

EA

0.01

21

7000001131

560

140

40 INSTALLATION- STRUCTURE

100001216 Erection of Pipe Structure - 400 kV 1-Phase SA including


nuts, bolts, all type of washers, packplates, step bolts
and gusset platesexcluding foundation bolts

EA

0.01

22

7000001131

560

140

50 INSTALLATION- STRUCTURE

100001215 Erection of Pipe Structure - 400 kV 1-Phase WT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

0.01

23

7000001131

560

140

60 INSTALLATION- STRUCTURE

100001217 Erection of Pipe Structure - 400 kV, 1-Phase, BPI,


(Excluding Wave Trap), including nuts, bolts, all type
of washers,packplates, step bolts and gusset plates
excluding foundation bolts

EA

0.01

24

7000001131

570

150

10 INSTALLATION- ERECTION
HARDWARE

100000339 Erection Hardware for 400kV I type layout-Any feeder


Extn. on existing half dia. as per specification

SET

0.01

25

7000001131

580

170

20 CIVIL WORKS

M3

1320

0.01

26

7000001131

580

170

30 CIVIL WORKS

M3

60

0.01

27

7000001131

580

170

40 CIVIL WORKS

100001324 Excavation in all types of soil and rock including


backfilling disposal etc. for all leads and lifts
100001325 Providing and laying of Plain Cement Concrete (PCC)
(1:4:8)
100001754 Providing and laying of Reinforced Cement Concrete
1:1.5:3 including pre cast, shuttering, Grouting of
pockets & underpinning butexcluding steel
reinforcement

M3

300

0.01

28

7000001131

580

170

50 CIVIL WORKS

100001328 Providing and laying Plain Cement Concrete 1:5:10 (1


cement : 5 sand : 10 brick aggregate)

M3

300

0.01

550

130

7000001131

550

130

16

7000001131

550

130

17

7000001131

550

130

18

7000001131

560

19

7000001131

20

12 = 10 x 11
0.01

Schedule-3/ Page 55 of 120

Installation Charges :
SI. No.
PR No

1
29
30

2
7000001131
7000001131

31

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

Total Erection
Charges

7
8
100001329 Steel Reinforcement
100001331 Misc. Structural steel including rails, embedments,
edge protection angles, gratings etc. but excluding the
reinforcement steel andsteel for lattice and pipe
structures.

9
MT
MT

10
12
20

11

100001375 Stone spreading and antiweed treatment in switchyard


excluding PCC
100001376 Removing,cleaning and washing of existing stones and
respreading of stones in switchyard after doing antiweed treatment excludingPCC

M2

4000

0.01

M2

600

0.01

100001674 Erection of 28mm dia foundation bolts including nuts,


checknuts, washers and packplates.
100001478 Cable Trench including all types of crossings, all
metallic works and sump pit including concrte and
reinforcement steel Section 2-2

EA

264

0.01

200

0.01

12 = 10 x 11
0.01
0.01

580
580

170
170

60 CIVIL WORKS
70 CIVIL WORKS

7000001131

580

170

90 CIVIL WORKS

32

7000001131

580

170

100 CIVIL WORKS

33

7000001131

580

170

160 CIVIL WORKS

34

7000001131

580

170

170 CIVIL WORKS

35

7000001131

580

170

180 CIVIL WORKS

100001479 Cable Trench including all types of crossings, all


metallic works and sump pit including concrte and
reinforcement steel Section 3-3

200

0.01

36

7000001131

580

170

200 CIVIL WORKS

100001720 Supplying, filling and compacting CNS material as per


specification under floors, foundations, roads, cable
trenches, drains etc inlayers not exceeding 200 mm
thickness

M3

150

0.01

37

7000001131

590

430

0.01

7000001131

590

430

100002181 1.1kV grade Power Cables (PVCinsulated)along


withlugs,glands,straight joints &accessories,etc.
100002182 1.1kV grade Control Cables (PVCinsulated) along
withlugs,glands,straight joints &accessories,etc.

LS

38

10 INSTALLATION- POWER &


CONTROL CABLES
30 INSTALLATION- POWER &
CONTROL CABLES

LS

0.01

100001898 420kV, 3150A, 50kA Circuit Breaker(3-Phase) without


closing resistor(withsupport structure)
100000270 420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with
120% extended currentrating
100000307 420kV, 3150A, 50KA, Isolator (3-phase)(Double Break)
with one E/S
100000304 420kV, 2000A, 50 KA, Isolator (3-phase)(Double Break)
with one E/S
100000328 336kV Surge Arrester (1-phase)
100000268 Controlled Switching Device for 420 kV, 3-ph Circuit
Breaker
100000435 245kV, 1600A, 40KA Circuit Breaker(3-Phase) with
support structure
100000443 245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with
120% extended currentrating

EA

0.01

EA

0.01

EA

0.01

EA

0.01

EA
EA

3
2

0.01
0.01

EA

0.01

EA

15

0.01

III

4 Nos. 220kV bays at NP Kunta SS

7000001130

610

150

10 400KV EQUIPMENTS

7000001130

610

150

20 400KV EQUIPMENTS

7000001130

610

150

30 400KV EQUIPMENTS

7000001130

610

150

40 400KV EQUIPMENTS

5
6

7000001130
7000001130

610
610

150
150

50 400KV EQUIPMENTS
60 400KV EQUIPMENTS

7000001130

620

160

10 220KV EQUIPMENTS

7000001130

620

160

20 220KV EQUIPMENTS

Schedule-3/ Page 56 of 120

Installation Charges :
SI. No.
PR No

1
9

2
7000001130

10

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

7
8
100000461 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator
with one E/S
100000462 245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator
with two E/S
100000464 245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem
Isolator without E/S
100000448 245 kV, 4400pf Capacitive Voltage Transformer (1Phase)
100000484 216kV Surge Arrester (1-phase)
100001907 245 kV,1 phase Bus Post Insulator (except for Line
Traps)
100000729 400kV Circuit Breaker Relay Panel without Auto Reclose
(with Automation)
100000731 400kV Transformer Protection Panel (For both HV & MV
side)-(with Automation)
100000736 220kV Circuit Breaker Relay Panel with Auto Reclose
(with Automation)
100000737 220kV Circuit Breaker Relay Panel without Auto Reclose
(with Automation)
100000738 220kV Line Protection Panel (with Automation)
100000772 Complete Substation automation System for 220kV bay
as per Technical Specification
100000878 220kV, 1600A, 0.5mH, 40 kA Line Trap
100000884 245 kV ,1 phase Bus Post Insulators for Line Traps
100001882 Air conditioning system for Switchyard Panel Room of
6m length
100000975 4.5 kg CO2 type Portable Fire extinguisher

Unit

Quantity

Unit
Erection
Charges

Total Erection
Charges

9
EA

10
5

11

EA

0.01

EA

10

0.01

EA

12

0.01

EA
EA

15
57

0.01
0.01

EA

0.01

EA

0.01

EA

0.01

EA

0.01

EA
EA

4
5

0.01
0.01

EA
EA
SET

4
12
1

0.01
0.01
0.01

EA

0.01

620

160

6
30 220KV EQUIPMENTS

12 = 10 x 11
0.01

7000001130

620

160

40 220KV EQUIPMENTS

11

7000001130

620

160

50 220KV EQUIPMENTS

12

7000001130

620

160

60 220KV EQUIPMENTS

13
14

7000001130
7000001130

620
620

160
160

70 220KV EQUIPMENTS
80 220KV EQUIPMENTS

15

7000001130

630

170

10 C&R PANEL (WITH SAS)

16

7000001130

630

170

20 C&R PANEL (WITH SAS)

17

7000001130

630

170

30 C&R PANEL (WITH SAS)

18

7000001130

630

170

40 C&R PANEL (WITH SAS)

19
20

7000001130
7000001130

630
640

170
180

50 C&R PANEL (WITH SAS)


10 SUBSTATION AUTOMATION

21
22
23

7000001130
7000001130
7000001130

650
650
660

190
190
200

10 PLCC EQIPMENTS
20 PLCC EQIPMENTS
10 AIR CONDITIONING SYSTEM

24

7000001130

670

210

10 FIRE PROTECTION SYSTEM

25

7000001130

670

210

20 FIRE PROTECTION SYSTEM

100000983 HVW spray system, Hydrant system and complete U/G


& O/G piping and accessories etc. out side the pump
house for 500MVA ,400KV/220/33 kV, 3-phase
Autotransformer

SET

0.01

26

7000001130

680

220

10 ILLUMINATION SYSTEM

EA

0.01

27

7000001130

680

220

20 ILLUMINATION SYSTEM

100001024 Sub Lighting panel (outdoor) type SLP (Switchyard and


Street Lighting)
100001041 Lighting Fixture type-SF1 as per technical specification

EA

0.01

28

7000001130

680

220

30 ILLUMINATION SYSTEM

100001042 Lighting Fixture type-SF2 as per technical specification

EA

10

0.01

29

7000001130

680

220

40 ILLUMINATION SYSTEM

SET

0.01

30

7000001130

690

230

10 STRUCTURE

100001116 Illumination System for switchyard panel room of 6 m


length
100001183 Erection of Std 220 kV Tower CA including nuts, bolts,
all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

Schedule-3/ Page 57 of 120

Installation Charges :
SI. No.
PR No

1
31

2
7000001130

32

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

7
8
100001187 Erection of Std 220 kV Tower CC including nuts, bolts,
all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

9
EA

10
1

11

Total Erection
Charges
12 = 10 x 11
0.01

690

230

20 STRUCTURE

7000001130

690

230

30 STRUCTURE

100001188 Erection of Std 220 kV Tower CD including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

33

7000001130

690

230

40 STRUCTURE

100001191 Erection of Std 220 kV Tower CTA including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

34

7000001130

690

230

50 STRUCTURE

100001192 Erection of Std 220 kV Tower CTB including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

35

7000001130

690

230

60 STRUCTURE

100001198 Erection of Std 220 kV Tower CTG including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

36

7000001130

690

230

70 STRUCTURE

100001204 Erection of Std 220 kV Gantry B1 including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

37

7000001130

690

230

80 STRUCTURE

100001205 Erection of Std 220 kV Gantry BG1 including nuts, bolts,


all type of washers, packplates, step bolts and gusset
plates excludingfoundation bolts

EA

0.01

38

7000001130

690

230

90 STRUCTURE

100001212 Erection of Pipe Structure - 400 kV 1-Phase CT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

0.01

39

7000001130

690

230

100 STRUCTURE

100001214 Erection of Pipe Structure - 400 kV 3-Phase ISOLATOR


including nuts, bolts, all type of washers, packplates,
step bolts and gussetplates excluding foundation bolts

EA

0.01

40

7000001130

690

230

110 STRUCTURE

100001216 Erection of Pipe Structure - 400 kV 1-Phase SA including


nuts, bolts, all type of washers, packplates, step bolts
and gusset platesexcluding foundation bolts

EA

0.01

41

7000001130

690

230

120 STRUCTURE

100001220 Erection of Pipe Structure - 220 kV 1-Phase CT including


nuts, bolts, all type of washers, packplates, step bolts
and gusset platesexcluding foundation bolts

EA

15

0.01

42

7000001130

690

230

130 STRUCTURE

100001221 Erection of Pipe Structure - 220 kV 1-Phase CVT


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

12

0.01

43

7000001130

690

230

140 STRUCTURE

100001222 Erection of Pipe Structure - 220 kV 3-Phase ISOLATOR


including nuts, bolts, all type of washers, packplates,
step bolts and gussetplates excluding foundation bolts

EA

20

0.01

Schedule-3/ Page 58 of 120

Installation Charges :
SI. No.
PR No

1
44

2
7000001130

45

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

7
8
100001223 Erection of Pipe Structure - 220 kV 1-Phase WT
including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

9
EA

10
4

11

Total Erection
Charges
12 = 10 x 11
0.01

690

230

150 STRUCTURE

7000001130

690

230

160 STRUCTURE

100001224 Erection of Pipe Structure - 220 kV 1-Phase SA including


nuts, bolts, all type of washers, packplates, step bolts
and gusset platesexcluding foundation bolts

EA

15

0.01

46

7000001130

690

230

170 STRUCTURE

100001225 Erection of Pipe Structure - 220 kV 1-Phase BPI


including nuts, bolts, all type of washers, packplates,
step bolts and gusset platesexcluding foundation bolts

EA

42

0.01

47

7000001130

690

230

180 STRUCTURE

EA

15

0.01

48

7000001130

690

230

190 STRUCTURE

EA

28

0.01

49

7000001130

690

230

200 STRUCTURE

EA

48

0.01

50

7000001130

690

230

220 STRUCTURE

EA

296

0.01

51

7000001130

700

240

10 ERECTION HARDWARE

100001226 Standard Pipe Structure for 220kV High BPI (excluding


wave trap)
100001677 Erection of 56mm dia foundation bolts including nuts,
checknuts, washers and packplates
100001676 Erection of 40mm dia foundation bolts including nuts,
checknuts, washers and packplates.
100001674 Erection of 28mm dia foundation bolts including nuts,
checknuts, washers and packplates.
100002891 Erection Hardware for 400kV I type layout-Any feeder
Extn. on existing half dia (for ICT Bay) (including all
requiredinterconnections for the transformer area). as
per technical specification

SET

0.01

52

7000001130

700

240

20 ERECTION HARDWARE

100000485 Erection Hardware for 220kV layout (Double Main and


Transfer Scheme as per SLD)-Line Bay as per
specification

SET

0.01

53

7000001130

700

240

30 ERECTION HARDWARE

100000491 Erection Hardware for 220kV layout (Double Main and


Transfer Scheme as per SLD)-Bus work (three Bay) as
per specification

SET

0.01

54

7000001130

700

240

40 ERECTION HARDWARE

100000486 Erection Hardware for 220kV layout (Double Main and


Transfer Scheme as per SLD)-Transformer Bay as per
specification

SET

0.01

55

7000001130

710

250

10 VISUAL MONITORING SYSTEM

100002500 Color IP camera, with PAN, TILT and ZOOM facilities,


alongwith all required Items, Accessories, Line Interface
units, Fiber patchcords, Power supply units, Junction
Boxes, Cables, Fiber Optic Cables, etc., and including
Integration in existing Hardware andSoftware for
Augmentation of Visual Monitoring System as per
technical specification.

SET

0.01

56

7000001130

720

270

10 CIVIL WORKS

M3

6100

0.01

57

7000001130

720

270

30 CIVIL WORKS

100001324 Excavation in all types of soil and rock including


backfilling disposal etc. for all leads and lifts
100001325 Providing and laying of Plain Cement Concrete (PCC)
(1:4:8)

M3

250

0.01
Schedule-3/ Page 59 of 120

Installation Charges :
SI. No.
PR No

1
58

2
7000001130

59

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

Total Erection
Charges

7
8
100001326 Providing and laying of Plain Cement Concrete (PCC)
(1:2:4)
100001327 Providing and laying of Reinforced Cement Concrete
M25 mix including pre cast, shuttering, Grouting of
pockets & underpinning butexcluding steel
reinforcement

9
M3

10
50

11

M3

1300

0.01

12 = 10 x 11
0.01

720

270

40 CIVIL WORKS

7000001130

720

270

60 CIVIL WORKS

60
61

7000001130
7000001130

720
720

270
270

80 CIVIL WORKS
120 CIVIL WORKS

100001329 Steel Reinforcement


100001331 Misc. Structural steel including rails, embedments,
edge protection angles, gratings etc. but excluding the
reinforcement steel andsteel for lattice and pipe
structures.

MT
MT

64
76

0.01
0.01

62

7000001130

720

270

160 CIVIL WORKS

M2

240

0.01

63

7000001130

720

270

170 CIVIL WORKS

100003114 External finishing / painting of fire wall (water proofing


cement paint) (DSR 13.44.1)
100001478 Cable Trench including all types of crossings, all
metallic works and sump pit including concrte and
reinforcement steel Section 2-2

600

0.01

64

7000001130

720

270

180 CIVIL WORKS

100001479 Cable Trench including all types of crossings, all


metallic works and sump pit including concrte and
reinforcement steel Section 3-3

600

0.01

65

7000001130

720

270

190 CIVIL WORKS

100003119 Switchyard Panel Room (6m x 3.5m) - All civil works as


per drawing and specification but excluding excavation,
PCC, RCC,reinforcement but including finishing (internal
and external) etc & all civil works complete in all
respect

EA

0.01

66

7000001130

720

270

210 CIVIL WORKS

100001720 Supplying, filling and compacting CNS material as per


specification under floors, foundations, roads, cable
trenches, drains etc inlayers not exceeding 200 mm
thickness

M3

500

0.01

67

7000001130

720

270

220 CIVIL WORKS

100002580 Construction of rail cum road as per drawing including


all item such as excavation,compactions, rolling
watering, WBM etc. butexcluding concrete
reinforcement and structural steel-Section having four
rails

M2

92

0.01

68

7000001130

720

270

230 CIVIL WORKS

100001376 Removing,cleaning and washing of existing stones and


respreading of stones in switchyard after doing antiweed treatment excludingPCC

M2

140

0.01

69

7000001130

720

270

240 CIVIL WORKS

M3

750

0.01

70

7000001130

730

400

10 POWER & CONTROL CABLES

LS

0.01

71

7000001130

730

400

20 POWER & CONTROL CABLES

100001330 Stone filling (40 mm size) for transformer/Reactor


foundation
100002181 1.1kV grade Power Cables (PVCinsulated)along
withlugs,glands,straight joints &accessories,etc.
100002182 1.1kV grade Control Cables (PVCinsulated) along
withlugs,glands,straight joints &accessories,etc.

LS

0.01

Schedule-3/ Page 60 of 120

Installation Charges :
SI. No.
PR No

IV

PR Line
Item No

Activity
Header

PR Activity Activity Description


No
5

Service Code

Description

Unit

Quantity

Unit
Erection
Charges

Total Erection
Charges

10

11

12 = 10 x 11

EA

0.01

SET

0.01

EA

0.01

EA

0.01

ICT-4 AT NP KUNTA SS (500 MVA)

7000001130

790

20

10 TRANSFORMER

7000001130

790

20

20 TRANSFORMER

7000001130

790

20

30 TRANSFORMER

7000001130

790

20

40 TRANSFORMER

100000015 500MVA, 400KV/220/33 KV, 3-phase Autotransformer


excluding insulating oil
100001910 Insulating Oil for 500MVA, 400KV/220/33 KV, 3-phase
Autotransformer
100000003 On line dissolved gas (multi gas) and moisture analyser
(As per technical specification)
100000004 On line insulating oil drying system (Cartridge type) (As
per technical specification)

Total Installation Charges

Date
:
Place
:

Note : EA means each


--

2.13

Printed Name :
Designation

Schedule-3/ Page 61 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation unde
Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension o
Substation (with 4 nos. of 220kV line bays) under Transmission system for Ultra M
Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation in
1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Mega So
Distt,
(SCHEDULE OF RATES
ANDAP-Part-C.
PRICES : ERECTION CHARGES)
Bidders Name and Address (Sole Bidder) :
Name
Address

:
:

All Price
SI. No.
1
Err:509
Err:509

Err:509

Err:509

Err:509
Err:509

Err:509

Err:509

Description

Unit

Quantity

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509

Err:509

2
Err:509
Err:509
Err:509
Err:509
Err:509

Schedule-3/ Page 62 of 120

All Price
SI. No.

Description

Unit

Quantity

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509

Err:509

Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509

Err:509
Err:509
Total Erection Price (A+B)

Date

: --

Place

Printed Name

Schedule-3/ Page 63 of 120

All Price
SI. No.
1

Description

Unit
2

Quantity

3
4
Designation

Schedule-3/ Page 64 of 120

Schedule - 3

ension of 400kV Tuticorin substation under Connectivity with


r-state Transmission System ii)Extension of 400/220kV NP Kunta
ays) under Transmission system for Ultra Mega Solar Park in
nsion of 400/220kV NP Kunta Substation including supply of
der Transmission system for Ultra Mega Solar Park in Anantapur
Distt,
TES
ANDAP-Part-C.
PRICES : ERECTION CHARGES)
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
All Prices are in Indian Rupees.
Unit Erection
Charges

Total Erection
Charges

6=4x5

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509

Err:509
Err:509

Err:509

Err:509
Schedule-3/ Page 65 of 120

All Prices are in Indian Rupees.


Unit Erection
Charges

Total Erection
Charges

6=4x5

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509
Err:509
Err:509

Err:509
Err:509
Err:509
Err:509

Err:509

Err:509

Err:509

Err:509

Err:509

Err:509
Err:509

Err:509

Err:509

Err:509
Err:509

Schedule-3/ Page 66 of 120

All Prices are in Indian Rupees.


Unit Erection
Charges

Total Erection
Charges

6=4x5

Schedule-3/ Page 67 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Schedule - 4

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Connectivity with Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extension
of 400/220kV NP Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system for Ultra Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP
Kunta Substation including supply of 1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.
(SCHEDULE OF RATES AND PRICES )
To:

Bidders Name and Address (Sole Bidder) :

Contract Services
Name

Power Grid Corporation of India Ltd.,

Address

"Saudamini", Plot No.-2


Sector-29,

Training Charges for Training to be imparted

SI. No.

PR No

Gurgaon (Haryana) - 122001

Line
Activity
PR Activity No
Item No Header

Activity
Description

Service Code Description

Unit

Quantity

Unit Charges

Total Charges

10

11

12=11x10

NOT APPLICABLE
TOTAL TRAINING CHARGES

0.00

Note : MND means -Man Days


Date

Place

--

Printed Name :
Designation :

Schedule-4/ Page 68 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Co
(2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP Kun
line bays) under Transmission system for Ultra Mega Solar Park in Anantapur di
400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotran
for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.

(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQ


Bidders Name and Address (Sole Bidder) :
Name

Address :

Sl. No.
1

Item Nos.
TOTAL EXCISE DUTY
Total Excise Duty for direct transaction between the Contractor and the
Employer (identified in Schedule 1 as 'Direct') which are not included in
the Ex-works price as per the provision of the Bidding Documents, as
applicable.
Rate of Excise Duty for Direct items indicated in
Sch-1

TOTAL SALES TAX


Total Sales Tax for direct transaction between the Contractor and the
Employer (identified in Schedule 1 as 'Direct') which are not included in
the Ex-works price as per the provision of the Bidding Documents, as
applicable.
Amount on which Sales Tax is applicable
w price]

[only ex-

Excise duty on this amount @ 0%

Rate of Sales Tax


3

5.00%

TOTAL VAT
Total VAT for direct transaction between the Contractor and the Employer
(identified in Schedule 1 as 'Direct') which are not included in the Exworks price as per the provision of the Bidding Documents, as applicable
Amount on which VAT is applicable
price]
Excise duty on this amount @ 0%

[only ex-w

0.00
0.00

Rate of VAT
4

TOTAL OCTROI

Schedule-5/ Page 69 of 120

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Co
(2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP Kun
line bays) under Transmission system for Ultra Mega Solar Park in Anantapur di
400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotran
for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.

(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQ


Bidders Name and Address (Sole Bidder) :
Name

Address :

Sl. No.

Item Nos.
Total Octroi as applicable for destination site/state on all items of supply,
as per the provisions of the Bidding Documents, on all items of Schedule
1.
Amount on which Octroi is applicable

Click here for details of Octroi

TOTAL ENTRY TAX


Total Entry Tax as applicable for destination site/state on all items of
supply, as per the provisions of the Bidding Documents, on all items of
Schedule 1.
Amount on which Entry Tax is applicable

Click here for details of Entry Taxes

TOTAL OTHER TAXES & DUTIES


Total Others levies payable in India (please specify) as applicable for
destination site/state on all items of supply, as per the provisions of the
Bidding Documents, on all items of Schedule 1.
Amount on which Other Taxes & Duties are
applicable

Click here for details of Other Taxes & D

GRAND TOTAL [1+2+3]


Above Grand Total does not include Octroi, Entry Tax , Other Taxes &
Duties quoted by bidder at Sl. No. 4,5 & 6 above

Note

The reimbursement of Excise Duty, Sales Tax/VAT and other levies as per Sl. No. 1
Clause 11.4 shall be only against those items for which the Mode of Transaction ind
of those items in the said Sechedule-1 against which the mode of transaction h
deemed to be 'Bought-out' for the purpose of Evaluation and award of Contract
against such items shall be deemed to be inclusive of all such taxes, duties and levi

Schedule-5/ Page 70 of 120

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Co
(2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP Kun
line bays) under Transmission system for Ultra Mega Solar Park in Anantapur di
400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotran
for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.

(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQ


Bidders Name and Address (Sole Bidder) :
Name

Address :

Sl. No.

Item Nos.

Date

Place

--

Printed Name

Designation

Schedule-5/ Page 71 of 120

Schedule - 5

00kV Tuticorin substation under Connectivity with Kundankulam 3 & 4


m ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV
Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of
of 1x500MVA, 400/220kV Autotransformer under Transmission system
rt-C.

UTIES APPLICABLE ON PLANT & EQUIPMENT)


To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)
0.00

0.00

0.00

Schedule-5/ Page 72 of 120

00kV Tuticorin substation under Connectivity with Kundankulam 3 & 4


m ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV
Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of
of 1x500MVA, 400/220kV Autotransformer under Transmission system
rt-C.

UTIES APPLICABLE ON PLANT & EQUIPMENT)


To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)

Plus Octroi, Entry Tax , Other Taxes & Duties


quoted by bidder at Sl. No. 4,5 & 6 above

x/VAT and other levies as per Sl. No. 1, 2 & 3 above subject to provision of ITB
s for which the Mode of Transaction indicated in Schedule - 1 is 'Direct'. In case
inst which the mode of transaction has been left blank, the same shall be
of Evaluation and award of Contract and the price indicated in Schedule 1
clusive of all such taxes, duties and levies.

Schedule-5/ Page 73 of 120

00kV Tuticorin substation under Connectivity with Kundankulam 3 & 4


m ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV
Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of
of 1x500MVA, 400/220kV Autotransformer under Transmission system
rt-C.

UTIES APPLICABLE ON PLANT & EQUIPMENT)


To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)

Schedule-5/ Page 74 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5


Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Co
(2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP Kun
line bays) under Transmission system for Ultra Mega Solar Park in Anantapur dist
400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotrans
for
Ultra Mega
Solar Park
in Anantapur
Distt,ON
AP-Part
SUMMARY
OF TAXES
& DUTIES
APPLICABLE
GOOD
Bidders Name and Address (Sole Bidder) :
Name

Address :

Sl. No.
1

Item Nos.
TOTAL EXCISE DUTY
Total Excise Duty for direct transaction between the Contractor and the
Employer (identified in Schedule 1 as 'Direct') which are not included in
the Ex-works price as per the provision of the Bidding Documents, as
applicable.
Rate of Excise Duty for Direct items indicated in
Sch-1

0.00%

TOTAL SALES TAX


Total Sales Tax for direct transaction between the Contractor and the
Employer (identified in Schedule 1 as 'Direct') which are not included in
the Ex-works price as per the provision of the Bidding Documents, as
applicable.
Amount on which Sales Tax is applicable
w price]

[only ex-

Excise duty on this amount @ 0%

Rate of Sales Tax


3

5.00%

TOTAL VAT
Total VAT for direct transaction between the Contractor and the Employer
(identified in Schedule 1 as 'Direct') which are not included in the Exworks price as per the provision of the Bidding Documents, as applicable
Amount on which VAT is applicable
price]
Excise duty on this amount @ 0%
Rate of VAT

[only ex-w

0.00
0.00
0.00%

TOTAL OCTROI

Schedule-5/ Page 75 of 120

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Co
(2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP Kun
line bays) under Transmission system for Ultra Mega Solar Park in Anantapur dist
400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotrans
for
Ultra Mega
Solar Park
in Anantapur
Distt,ON
AP-Part
SUMMARY
OF TAXES
& DUTIES
APPLICABLE
GOOD
Bidders Name and Address (Sole Bidder) :
Name

Address :

Sl. No.

Item Nos.
Total Octroi as applicable for destination site/state on all items of supply,
as per the provisions of the Bidding Documents, on all items of Schedule
1.
Amount on which Octroi is applicable

Click here for details of Octroi

TOTAL ENTRY TAX


Total Entry Tax as applicable for destination site/state on all items of
supply, as per the provisions of the Bidding Documents, on all items of
Schedule 1.
Amount on which Entry Tax is applicable

Click here for details of Entry Taxes

TOTAL OTHER TAXES & DUTIES


Total Others levies payable in India (please specify) as applicable for
destination site/state on all items of supply, as per the provisions of the
Bidding Documents, on all items of Schedule 1.
Amount on which Other Taxes & Duties are
applicable

Click here for details of Other Taxes & D

GRAND TOTAL [1+2+3]


Above Grand Total does not include Octroi, Entry Tax , Other Taxes &
Duties quoted by bidder at Sl. No. 4,5 & 6 above

Note

The reimbursement of Excise Duty, Sales Tax/VAT and other levies as per Sl. No. 1
Clause 11.4 shall be only against those items for which the Mode of Transaction ind
of those items in the said Sechedule-1 against which the mode of transaction h
deemed to be 'Bought-out' for the purpose of Evaluation and award of Contract
against such items shall be deemed to be inclusive of all such taxes, duties and levi

Schedule-5/ Page 76 of 120

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Co
(2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV NP Kun
line bays) under Transmission system for Ultra Mega Solar Park in Anantapur dist
400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotrans
for
Ultra Mega
Solar Park
in Anantapur
Distt,ON
AP-Part
SUMMARY
OF TAXES
& DUTIES
APPLICABLE
GOOD
Bidders Name and Address (Sole Bidder) :
Name

Address :

Sl. No.

Item Nos.

Date

Place

--

Printed Name

Designation

Schedule-5/ Page 77 of 120

Schedule - 5
00kV Tuticorin substation under Connectivity with Kundankulam 3 & 4
m ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV
Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of
of 1x500MVA, 400/220kV Autotransformer under Transmission system
ar Park
in Anantapur
Distt,ON
AP-Part-C.
XES
& DUTIES
APPLICABLE
GOODS
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)
0.00

0.00

0.00

Schedule-5/ Page 78 of 120

00kV Tuticorin substation under Connectivity with Kundankulam 3 & 4


m ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV
Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of
of 1x500MVA, 400/220kV Autotransformer under Transmission system
ar Park
in Anantapur
Distt,ON
AP-Part-C.
XES
& DUTIES
APPLICABLE
GOODS
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)

0.00
Plus Octroi, Entry Tax , Other Taxes & Duties
quoted by bidder at Sl. No. 4,5 & 6 above

x/VAT and other levies as per Sl. No. 1, 2 & 3 above subject to provision of ITB
s for which the Mode of Transaction indicated in Schedule - 1 is 'Direct'. In case
inst which the mode of transaction has been left blank, the same shall be
of Evaluation and award of Contract and the price indicated in Schedule 1
clusive of all such taxes, duties and levies.

Schedule-5/ Page 79 of 120

00kV Tuticorin substation under Connectivity with Kundankulam 3 & 4


m ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV
Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of
of 1x500MVA, 400/220kV Autotransformer under Transmission system
ar Park
in Anantapur
Distt,ON
AP-Part-C.
XES
& DUTIES
APPLICABLE
GOODS
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)

Schedule-5/ Page 80 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation


Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Ext
Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system fo
in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substa
1x500MVA, 400/220kV Autotransformer under Transmission system for Ultr
Anantapur Distt, AP-Part-C.
(GRAND SUMMARY)
Bidders Name and Address (Sole Bidder) :

Name

Address :

Sl. No.
1

Description
TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test
Charges

TOTAL SCHEDULE NO. 2


Local Transportation, Insurance and other Incidental Services

TOTAL SCHEDULE NO. 3


Installation Charges

TOTAL SCHEDULE NO. 4


Training Charges

TOTAL SCHEDULE NO. 5

Taxes and Duties


6

TOTAL SCHEDULE NO. 7


Type Test Charges
[Total of this Schedule is included in Schedule - 1 above.]

GRAND TOTAL [1+2+3+4+5]

Schedule-6/ Page 81 of 120

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation


Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Ext
Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system fo
in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substa
1x500MVA, 400/220kV Autotransformer under Transmission system for Ultr
Anantapur Distt, AP-Part-C.
(GRAND SUMMARY)
Bidders Name and Address (Sole Bidder) :

Name

Address :

Sl. No.

Description
GRAND TOTAL [1+2+3+4+5]

Date

Place

--

Printed Name

Designation

Schedule-6/ Page 82 of 120

Schedule - 6

) Extension of 400kV Tuticorin substation under Connectivity with


with Inter-state Transmission System ii)Extension of 400/220kV NP
0kV line bays) under Transmission system for Ultra Mega Solar Park
i)Extension of 400/220kV NP Kunta Substation including supply of
rmer under Transmission system for Ultra Mega Solar Park in
(GRAND SUMMARY)
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)
2.55

2.55

2.13

0.00

0.00
Plus Octroi, Entry Tax , Other Taxes &
Duties quoted by bidder at Sl. No. 4, 5 & 6
of Sch-5
0.00

7.23

Schedule-6/ Page 83 of 120

) Extension of 400kV Tuticorin substation under Connectivity with


with Inter-state Transmission System ii)Extension of 400/220kV NP
0kV line bays) under Transmission system for Ultra Mega Solar Park
i)Extension of 400/220kV NP Kunta Substation including supply of
rmer under Transmission system for Ultra Mega Solar Park in
(GRAND SUMMARY)
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)
Plus Octroi, Entry Tax , Other Taxes &
Duties quoted by bidder at Sl. No. 4, 5 &
6 of Sch-5

Schedule-6/ Page 84 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation


Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Ext
Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system fo
in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substa
1x500MVA, 400/220kV Autotransformer under Transmission system for Ultr
Anantapur Distt, AP-Part-C.
(GRAND SUMMARY)
Bidders Name and Address (Sole Bidder) :

Name

Address :

Sl. No.
1

Description
TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test
Charges

TOTAL SCHEDULE NO. 2


Local Transportation, Insurance and other Incidental Services

TOTAL SCHEDULE NO. 3


Installation Charges

TOTAL SCHEDULE NO. 4


Training Charges

TOTAL SCHEDULE NO. 5

Taxes and Duties


6

TOTAL SCHEDULE NO. 7


Type Test Charges
[Total of this Schedule is included in Schedule - 1 above.]

GRAND TOTAL [1+2+3+4+5]

Schedule-6/ Page 85 of 120

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation


Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Ext
Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system fo
in Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substa
1x500MVA, 400/220kV Autotransformer under Transmission system for Ultr
Anantapur Distt, AP-Part-C.
(GRAND SUMMARY)
Bidders Name and Address (Sole Bidder) :

Name

Address :

Sl. No.

Description

Date

Place

--

Printed Name

Designation

Schedule-6/ Page 86 of 120

Schedule - 6 After Discount

) Extension of 400kV Tuticorin substation under Connectivity with


with Inter-state Transmission System ii)Extension of 400/220kV NP
0kV line bays) under Transmission system for Ultra Mega Solar Park
i)Extension of 400/220kV NP Kunta Substation including supply of
rmer under Transmission system for Ultra Mega Solar Park in
(GRAND SUMMARY)
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)
2.55

2.55

2.13

0.00

0.00
Plus Octroi, Entry Tax , Other Taxes &
Duties quoted by bidder at Sl. No. 4,5 & 6
of Sch-5
0.00

7.23
Plus Octroi, Entry Tax , Other Taxes &
Duties quoted by bidder at Sl. No. 4,5 & 6
of Sch-5
Schedule-6/ Page 87 of 120

) Extension of 400kV Tuticorin substation under Connectivity with


with Inter-state Transmission System ii)Extension of 400/220kV NP
0kV line bays) under Transmission system for Ultra Mega Solar Park
i)Extension of 400/220kV NP Kunta Substation including supply of
rmer under Transmission system for Ultra Mega Solar Park in
(GRAND SUMMARY)
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Total Price (INR)

Schedule-6/ Page 88 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under Connectivity with Kundankulam 3 &
Transmission System ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of 220kV line bays) under Transmission s
Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV A
system for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.
(SCHEDULE OF RATES AND PRICES )
Bidders Name and Address (Sole Bidder) :

To:
Contract Services
Power Grid Corporati
"Saudamini", Plot No
Sector-29,
Gurgaon (Haryana) -

Name
:
Address :

Type Tests to be conducted

PR No

SL. NO.

Line Item
Code
No

Description of Test

Unit Quantity

NOT APPLICABLE
TOTAL TYPE TEST CHARGES
Note : EA means-each
Date
Place
Note

:
:
:

--

Printed Name
Designation

:
:

Bidder should indicate the name of test laboratories where type tests are proposed to be conducted

Schedule-7/ Page 89 of 120

Schedule 7

substation under Connectivity with Kundankulam 3 & 4 (2x 1000 MW) with Inter-state
n (with 4 nos. of 220kV line bays) under Transmission system for Ultra Mega Solar Park in
Substation including supply of 1x500MVA, 400/220kV Autotransformer under Transmission

DULE OF RATES AND PRICES )

Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001

Testing
Unit Test Charge
location

Total Test
Charges (Rs.)

0.00

Printed Name
Designation

:
:

e tests are proposed to be conducted

Schedule-7/ Page 90 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation under
4 (2x 1000 MW) with Inter-state Transmission System ii)Extension of 400/220kV N
220kV line bays) under Transmission system for Ultra Mega Solar Park in Anantapu
400/220kV NP Kunta Substation including supply of 1x500MVA, 400/220kV Autotra
for Ultra Mega Solar Park in Anantapur Distt, AP-Pa
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHAR

Bidders Name and Address (Sole Bidder) :

Name

Address :

Type Tests on Earthwire


SL. NO.

Description of Test
Err:509
(a) NOT APPLICABLE
(b) 0
Sub-Total (I)
TOTAL TEST CHARGES (I)

Date

Place

Note

--

Unit

0
0

Quantity

0
0

Signature

Printed Name

Designation

Common Seal

Bidder should indicate the name of test laboratories where type tests are propo

Schedule-7/ Page 91 of 120

of 400kV Tuticorin substation under Connectivity with Kundankulam 3 &


System ii)Extension of 400/220kV NP Kunta Substation (with 4 nos. of
r Ultra Mega Solar Park in Anantapur distt, AP-Part-B and iii)Extension of
ly of 1x500MVA, 400/220kV Autotransformer under Transmission system
Solar Park in Anantapur Distt, AP-Part-C.
RATES AND PRICES : TYPE TEST CHARGES)

To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001

Unit Test Charge

0
0

Signature

Printed Name

Designation

Common Seal

Total Test
Charges
(Rs.)
Included
Included
0.00
0.00

laboratories where type tests are proposed to be conducted

Schedule-7/ Page 92 of 120

Specification No.: CC-CS/675-SR1/SS-3256/3/G5


LETTER OF DISCOUNT
To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject :

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin substation un


Kundankulam 3 & 4 (2x 1000 MW) with Inter-state Transmission System ii)Extens
Kunta Substation (with 4 nos. of 220kV line bays) under Transmission system for Ul
Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation
1x500MVA, 400/220kV Autotransformer under Transmission system for Ultra Mega S
Distt, AP-Part-C.

Dear Sir

With reference to the subject tender, we hereby offer unconditional discount on the prices quoted
given here below :
1

Discount on lum-sum basis on total price quoted by us without Taxes & Dut
[The discount shall be proportionately applicable on all the items of all the Schdules
Sch-1 (without type test charges), Sch-2, Sch-3,Sch-4 & Sch-7] In Rs.

Discount on percent basis on total price quoted by us without Taxes & Dut
[The discount shall be proportionately applicable on all the items of all the Schdules
Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%)

Discount on lum-sum basis on the Schedules as given below : [The discount s


be proportionately applicable on all the relevent items of the respective Schdules.
Rs.
Schedule-1 : Ex works prices (Direct Only)
Schedule-1 : Ex works prices (Bought Out Only)
Schedule-2 : Freight & Insurance
Schedule-3 : Erection Charges
Schedule-4 : Training Charges
Schedule-7 : Type Test Charges
Letter of Discount / Page 93 of 120

Discount on percent basis on the Schedules as given below : [The discount s


be proportionately applicable on all the relevent items of the respective Schdules.
Percent (%)
Schedule-1 : Ex works prices (Direct Only)
Schedule-1 : Ex works prices (Bought Out Only)
Schedule-2 : Freight & Insurance
Schedule-3 : Erection Charges
Schedule-4 : Training Charges
Schedule-7 : Type Test Charges

Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatic
items of the Schedules.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,

Date :
Place :

--

Printed Name :
Designation :

Letter of Discount / Page 94 of 120

Letter of Discount

corin substation under Connectivity with


ion System ii)Extension of 400/220kV NP
ission system for Ultra Mega Solar Park in
NP Kunta Substation including supply of
em for Ultra Mega Solar Park in Anantapur

on the prices quoted by us as per details

thout Taxes & Duties.


s of all the Schdules i.e.
n Rs.

thout Taxes & Duties.


s of all the Schdules i.e.
In Percent (%)

ow : [The discount shall


respective Schdules.] In

In Rs.
In Rs.
In Rs.
In Rs.
In Rs.
In Rs.
Letter of Discount / Page 95 of 120

ow : [The discount shall


respective Schdules.] In
In Percent (%)
In Percent (%)
In Percent (%)
In Percent (%)
In Percent (%)
In Percent (%)

ounted for automatically in the respective

Yours faithfully,
For and on behalf of

Letter of Discount / Page 96 of 120

Details of Octroi
Sl No.

Description of Items

(1)

(2)

10

Total

Amount on which Octroi


is applicable
(3)

Back to Sch 5

Rate of Octroi

Octroi

(4)

(5) =(3) x (4)


0

Details of Entry Tax


Sl No.

Description of Items

(1)

(2)

10

Total

Amount on which Entry


Tax is applicable
(3)

Rate of Entry Tax

Entry Tax

(4)

(5) =(3) x (4)


0

Details of Other Taxes & Duties

Sl No. Description of Items


(1)

(2)

10

Total

Amount on which
Description of Taxes &
Other Taxes & Duties
Duties
are applicable
(3)

(4)

Rate of
Taxes &
Duties

Amount of
Taxes &
Duties

(5)

(6) =(3) x (4)


0

Specification No.: CC-CS/675-SR1/SS-3256/3/G5


BID FORM (Second Envelope)
Bid Proposal Ref. No.
Date
: -To:
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29,
Gurgaon (Haryana) - 122001
Name of Contract :

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin


under Connectivity with Kundankulam 3 & 4 (2x 1000 MW) with
Transmission System ii)Extension of 400/220kV NP Kunta Substat
nos. of 220kV line bays) under Transmission system for Ultra Mega S
Anantapur distt, AP-Part-B and iii)Extension of 400/220kV NP Kunta
including supply of 1x500MVA, 400/220kV Autotransformer under T
system for Ultra Mega Solar Park in Anantapur Distt, AP-Part-C.

Dear Ladies and/or Gentlemen,


1.0

In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of th
which shall be read together and in conjunction with each other, and shall be construed a
part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, d
and commission (including carrying out Trial Operation, Performance & Guarantee
provision of Technical Specification) under the above-named package in full conformity
Bidding Documents for the sum of Rs. 7.22999999999998 (Rs. Seven Only) Plus appl
Entry Tax, Other Taxes & Duties or such other sums as may be determined in accorda
terms and conditions of the Bidding Documents.

The above amounts are in accordance with the price schedules attached herewith and a
of this bid.
2.0

Price Schedules

2.1

In line with the requirements of the Bidding documents, we enclose herewith the fo
Schedules, duly filled - in as per your proforma:
Schedule 1

Plant and Equipment (Including Mandatory Spare Parts) to


including Type Test Charges.

Bid Form (1st Envelope) / Page 103 of 120

Schedule 2

Local Transportation, Insurance and other Incidental services.

Schedule 3

Installation Charges.

Schedule 4

Training charges for training to be imparted.

Schedule 5

Taxes and Duties not included in Schedule 1

Schedule 6

Grand Summary [Schedule 1to 5]

Schedule 7

Break-up of Type Test Charges for Type Tests to be conducted

2.2

We are aware that the Price Schedules do not generally give a full description of the
performed under each item and we shall be deemed to have read the Technical Spec
other sections of the Bidding Documents and Drawings to ascertain the full scope of Wor
each item while filling-in the rates and prices. We agree that the entered rates and pr
deemed to include for the full scope as aforesaid, including overheads and profit.

2.3

We declare that as specified in Clause 11.5, Section II:ITB, Vol.-I of the Bidding Docum
quoted by us in the Price Schedules shall be subject to Price Adjustment during the
Contract in accordance with Appendix-2 (Price Adjustment) to the Contract Agreement.

2.4

We understand that in the price schedules, where there are errors between the total of
given under the column for the price Breakdown and the amount given under the To
former shall prevail and the latter will be corrected accordingly. We further understan
there are discrepancies between amounts stated in figures and amounts stated in words
stated in words shall prevail. Similarly, any discrepancy in the total bid price and
summation of Schedule price (price indicated in a Schedule indicating the total of that s
total bid price shall be corrected to reflect the actual summation of the Schedule prices.

2.5

We declare that items left blank in the Schedules will be deemed to have been inclu
items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deem
total price for executing the Facilities and sections thereof in complete accordance with
whether or not each individual item has been priced.

Bid Form (1st Envelope) / Page 104 of 120

3.0

We confirm that except as otherwise specifically provided our Bid Prices in this Seco
include all taxes, duties, levies and charges as may be assessed on us/our Associate (a
Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, sta
government authorities in connection with the Facilities, in and outside of India.

3.2

We further understand that notwithstanding 3.0 above, in case of award on us, you shall
pay/reimburse to us, Excise Duty, Sales Tax/VAT (but not the surcharge in lieu of Sales T
tax and other levies in respect of direct transaction between you and us, imposed on
Equipment including Mandatory Spare Parts specified in Schedule No. 1 of the Price Sch
Second Envelope, to be incorporated into the Facilities; by the Indian Laws.

3.3

We also understand that, in case of award on us, you shall pay directly, if so required /rei
octroi/entry tax as applicable for destination site/state on all items of supply includin
finished items, which shall be dispatched directly from the sub-vendors works to the Em
(sale-in-transit). Further, Service Tax, if applicable, for the services to be rendered by us
included in our bid price in this Second Envelope.

3.4

We confirm that we shall also get registered with the concerned Sales Tax Authorities, in
where the project is located.

3.5

We confirm that no Sales Tax/VAT in any form shall be payable by you for the bought ou
shall be despatched directly by us under the First Contract to the project site. However,
requisite Sales Tax declaration/Vatable forms in respect of such bought out items, on
documentary evidence of registration with the concerned Sales Tax Authorities.

4.0

# (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree
that in case of Award of Contract on the Joint Venture, we shall be jointly and severa
responsible for the execution of the Contract in accordance with Contract terms and cond

5.0

We, hereby, declare that only the persons or firms interested in this proposal as principa
here and that no other persons or firms other than those mentioned herein have any in
proposal or in the Contract to be entered into, if the award is made on us, that this prop
without any connection with any other person, firm or party likewise submitting a prop
respects for and in good faith, without collusion or fraud.

Bid Form (1st Envelope) / Page 105 of 120

Thanking you, we remain,

Signature :
Date
Place

--

Printed Name :
Designation :
Common Seal :

Bid Form (1st Envelope) / Page 106 of 120

Please provide additional information of the Bidder


Business Address

Country of Incorporation

State/Province to be indicated :
Name of Principal Officer

Address of Principal Officer

Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Powe
Bidders may use their own proforma for furnishing the required information with the bid.

***

Bid Form (1st Envelope) / Page 107 of 120

Bid Form 2nd Envelope

elope)

Extension of 400kV Tuticorin substation


m 3 & 4 (2x 1000 MW) with Inter-state
400/220kV NP Kunta Substation (with 4
ission system for Ultra Mega Solar Park in
ension of 400/220kV NP Kunta Substation
20kV Autotransformer under Transmission
nantapur Distt, AP-Part-C.

submit the Second Envelope of the Bid, both of


ach other, and shall be construed as an integral
er to design, manufacture, test, deliver, install
ation, Performance & Guarantee Test as per
named package in full conformity with the said
99998 (Rs. Seven Only) Plus applicable Octroi,
as may be determined in accordance with the

chedules attached herewith and are made part

ents, we enclose herewith the following Price

uding Mandatory Spare Parts) to be supplied,


s.

Bid Form (1st Envelope) / Page 108 of 120

ance and other Incidental services.

g to be imparted.

ded in Schedule 1

ges for Type Tests to be conducted

rally give a full description of the Work to be


to have read the Technical Specifications and
s to ascertain the full scope of Work included in
ree that the entered rates and prices shall be
ding overheads and profit.

II:ITB, Vol.-I of the Bidding Documents, prices


t to Price Adjustment during the execution of
ent) to the Contract Agreement.

re are errors between the total of the amounts


d the amount given under the Total Price, the
accordingly. We further understand that where
ures and amounts stated in words, the amount
pancy in the total bid price and that of the
edule indicating the total of that schedule), the
ummation of the Schedule prices.

ll be deemed to have been included in other


of Grand Summary shall be deemed to be the
reof in complete accordance with the Contract,

Bid Form (1st Envelope) / Page 109 of 120

vided our Bid Prices in this Second Envelope


e assessed on us/our Associate (applicable for
ir employees by all municipal, state or national
s, in and outside of India.

in case of award on us, you shall also bear and


ot the surcharge in lieu of Sales Tax/VAT), local
between you and us, imposed on the Plant &
in Schedule No. 1 of the Price Schedule in this
by the Indian Laws.

hall pay directly, if so required /reimburse to us


e on all items of supply including bought-out
m the sub-vendors works to the Employers site
the services to be rendered by us, the same is

oncerned Sales Tax Authorities, in all the states

payable by you for the bought out items which


ract to the project site. However, you will issue
ct of such bought out items, on production of
ed Sales Tax Authorities.

nture submitting this bid, do agree and confirm


e, we shall be jointly and severally liable and
ance with Contract terms and conditions.

erested in this proposal as principals are named


ose mentioned herein have any interest in this
ward is made on us, that this proposal is made
r party likewise submitting a proposal is in all
d.

Bid Form (1st Envelope) / Page 110 of 120

Yours faithfully,
For and on behalf of

Bid Form (1st Envelope) / Page 111 of 120

nclosed for Attachment 2 : Power of Attorney.


ormation with the bid.

Bid Form (1st Envelope) / Page 112 of 120

STATEMENT OF QUOTED / CORRECTED PRIC

Bidder
Sl. No.

Price Component

TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and


Equipment including Type Test Charges

TOTAL SCHEDULE NO.2: Local Transportation, Insurance


and other Incidental Services.

TOTAL SCHEDULE NO.3: Installation Charges

TOTAL SCHEDULE NO.4: Training Charges

TOTAL BID PRICE: (Excluding Taxes & Duties)

DISCOUNT

NET BID PRICE (Excluding Taxes & Duties)

TAXES & DUTIES PAYABLE ADDITIONALLY


A) EXCISE DUTY
B) CENTRAL SALES TAX
C) VAT
D) ENTRY TAX / OCTROI
E) OTHERS
F)

TOTAL TAXES & DUTIES

TOTAL BID PRICE (INCLUDING TAXES & DUTIES)

TOTAL SCHEDULE NO.7: Type Test Charges


[Total of this Schedule is included in Schedule-1 above]

I)

Bidder has indicated the following taxes and duties additionally applicable fo
Excise Duty
CST

% as

VAT

% as

% as

Entry Tax/ Octroi


Others
II)

as

as

With regard to Entry Tax, it may be mentioned that the substations covered
State of MP, where an entry tax @ 2% of Purchase Price is applicable. In v
duties inter-alia including entry tax applicable for the bids are calculated :
a
Ex-Works Price of Direct Supplies (after discount, if any)
)

b
Excise Duty, as applicable on (a) above at the rate :
)
c
Amount on which Sales Tax is applicable
)
d
CST, as applicable on (a) + ED (b) above at the rate :
)
e
VAT, as applicable on (a) + ED (b) above at the rate :
)
f
Others []
)
g
Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others)
)
h
Entry Tax, as applicable on (e) above at the rate :
)

Substation Package SS02 (AIS) for i) Extension of 400kV Tuticorin


substation under Connectivity with Kundankulam 3 & 4 (2x 1000
MW) with Inter-state Transmission System ii)Extension of 400/220kV
NP Kunta Substation (with 4 nos. of 220kV line bays) under
Transmission system for Ultra Mega Solar Park in Anantapur distt,
AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation
including supply of 1x500MVA, 400/220kV Autotransformer under
Spec.
No. Specification
No.:Ultra
CC-CS/675-SR1/SS-3256/3/G5
Transmission
system for
Mega Solar Park in Anantapur Distt,
AP-Part-C.

STATEMENT OF QUOTED / CORRECTED PRICES


All Figures are in Rupees
#VALUE!
Quoted Price

Corrected Price

2.55

2.55

2.55

2.55

2.13

2.13

Not Applicable

Not Applicable

7.23

7.23

Err:509

Err:509

Err:509

Err:509

0.00

0.00

0.00

0.00

0.00
0

0.00

7.23

7.23

0.00

0.00

wing taxes and duties additionally applicable for their bid:

ay be mentioned that the substations covered under the subject pacakge falls in
tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and
y tax applicable for the bids are calculated :

ies (after discount, if any)

Rs.

10.00% Rs.

0.00

2.00% Rs.

1.00%

0
Rs.

otal Ex-Works+F&I+ED+CST+Others)

Rs.

Rs.

0.00

Statement of Quoted /
Corrected Prices

Page

STATEMENT OF QUOTED / CORRECTED PRIC

Bidder
Sl. No.

Price Component

TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and


Equipment including Type Test Charges

TOTAL SCHEDULE NO.2: Local Transportation, Insurance


and other Incidental Services.

TOTAL SCHEDULE NO.3: Installation Charges

TOTAL SCHEDULE NO.4: Training Charges

TOTAL BID PRICE: (Excluding Taxes & Duties)

DISCOUNT

NET BID PRICE (Excluding Taxes & Duties)

TAXES & DUTIES PAYABLE ADDITIONALLY


A) EXCISE DUTY
B) CENTRAL SALES TAX /VAT
C) ENTRY TAX / OCTROI
D) OTHERS
E)

TOTAL TAXES & DUTIES

TOTAL BID PRICE (INCLUDING TAXES & DUTIES)

TOTAL SCHEDULE NO.7: Type Test Charges


[Total of this Schedule is included in Schedule-1 above]

I)

II)

III)

Bidder has indicated the following taxes and duties additionally applicable fo
a
Excise Duty
)
b
CST /VAT
)
c
Entry Tax / Octroi
)
d
Others
)
Bidder has offered following discount(s)

With regard to Entry Tax, it may be mentioned that the substations covered
State of MP, where an entry tax @ 1% of Purchase Price is applicable. In v
duties inter-alia including entry tax applicable for the bids are calculated :
a
Ex-Works Price of Direct Supplies (after discount, if any)
)

b
Excise Duty @ 10.3% of (a) above
)
c
CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above
)
d
Others
)e
Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others)
)f
Entry
Tax @ 1% of (e) above
Substation
) Package SS02 (AIS) for i) Extension of 400kV Tuticorin
substation under Connectivity with Kundankulam 3 & 4 (2x 1000
MW) with Inter-state Transmission System ii)Extension of 400/220kV
NP Kunta Substation (with 4 nos. of 220kV line bays) under
Transmission system for Ultra Mega Solar Park in Anantapur distt,
AP-Part-B and iii)Extension of 400/220kV NP Kunta Substation
including supply of 1x500MVA, 400/220kV Autotransformer under
Transmission system for Ultra Mega Solar Park in Anantapur Distt,
AP-Part-C.

STATEMENT OF QUOTED / CORRECTED PRICES


All Figures are in Rupees
Quoted Price

Corrected Price

2.55

2.55

2.55

2.55

2.13

2.13

Not Applicable

Not Applicable

7.23

7.23

Err:509

Err:509
Err:509

Err:509

0.00

0.00

0.00

0.00

#REF!

0.00

#REF!

0.00

#REF!

0.00

#REF!

7.23

0.00

0.00

wing taxes and duties additionally applicable for their bid:


Rs.

0.00

Rs.

0.00

Rs.
Rs.

scount(s)

ay be mentioned that the substations covered under the subject pacakge falls in
tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and
y tax applicable for the bids are calculated :

ies (after discount, if any)

Rs.

ove

Rs.

f Direct Supplies (a) + ED (b) above

Rs.

Rs.

otal Ex-Works+F&I+ED+CST+Others)

Rs.
Rs.

Statement of Quoted /
Corrected Prices

5.10
0.00

Page