Académique Documents
Professionnel Documents
Culture Documents
INSTALLATION INSTRUCTIONS
PN375B
6
4
3
2
7
5
1
GRN/
BRN/
BLU/
ORG/
T568B BRN WHT GRN WHT BLU WHT ORG WHT
Pin #
(Cable end 1)
Specifications
Load Bar
Divider
Pins
8
Conductor holes
V channel
Contact slots
Divider post
Thread on Boot
and Collar first!
CWST
90
(Cable end 2)
BLU
(Cable end 1)
GRN
ORG
V channel
ORG
V channel
GRN
BRN
BLU
BRN
V channel
(Cable end 1)
(Cable end 2)
INSTALLATION INSTRUCTIONS
4
8
6
4
3
2
7
5
1
Pin #
GRN/
BRN/
BLU/
ORG/
T568B BRN WHT GRN WHT BLU WHT ORG WHT
PN375B
1.00"
(Cable end 1)
(Cable end 2)
Verify
Load Bar
orientation
(Cable end 1)
1
8
Pins
1
Pins
(Cable end 1)
(Cable end 2)
Drain Wire
Collar Barbs
Collar Latches
Strain Collar
Guides
Boot position
when using
CSPT
Pins
(Cable end 1)
1
Pins
Orient cable so drain wire is facing up. While holding the Load
Bar and Divider stationary, slide the Collar towards the
termination point until there is no gap between the Collar and
Divider. Ensure the drain wire is routed through the Strain
Collar Guides. Do not exert pressure onto the Divider, the
Collar can push the Load Bar off the conductors.
Confirm orientation of Collar. Cable jacket should extend
beyond Collar barbs.
Align Pin #1 of cable sub-assembly (Cable, Load Bar, Divider,
Collar with Boot) with Pin #1 of Plug Housing.
Collar Locking
Tabs
10
MPT5-8A
INSTALLATION INSTRUCTIONS
PN375B
6
4
3
2
7
5
1
ORG/
BRN/
BLU/
GRN/
T568A BRN WHT ORG WHT BLU WHT GRN WHT
Pin #
(Cable end 1)
Specifications
Strain Relief Boot
Strain Relief Collar
Divider
Load Bar
Plug Housing with Shield
Load Bar
Divider
Pins
8
Conductor holes
V channel
Contact slots
Thread on Boot
and Collar first!
CWST
90
(Cable end 2)
BLU
(Cable end 1)
ORG
GRN
V channel
Divider post
GRN
V channel
ORG
BRN
BLU
BRN
V channel
(Cable end 1)
(Cable end 2)
INSTALLATION INSTRUCTIONS
4
8
7
5
1
6
4
3
2
Pin #
BRN/
BLU/
GRN/
ORG/
T568A BRN WHT ORG WHT BLU WHT GRN WHT
1.00"
PN375B
(Cable end 1)
(Cable end 2)
Verify
Load Bar
orientation
(Cable end 1)
1
Pins
8
1
Pins
(Cable end 1)
(Cable end 2)
Drain Wire
Collar Barbs
Collar Latches
Strain Collar
Guides
Boot position
when using
CSPT
Pins
(Cable end 1)
1
Pins
Orient cable so drain wire is facing up. While holding the Load
Bar and Divider stationary, slide the Collar towards the
termination point until there is no gap between the Collar and
Divider. Ensure the drain wire is routed through the Strain
Collar Guides. Do not exert pressure onto the Divider, the
Collar can push the Load Bar off the conductors.
Confirm orientation of Collar. Cable jacket should extend
beyond Collar barbs.
Align Pin #1 of cable sub-assembly (Cable, Load Bar, Divider,
Collar with Boot) with Pin #1 of Plug Housing.
Collar Locking
Tabs
10
MPT5-8A
www.panduit.com
Page 4 of 4
Fax:
(708) 444-6993