Part Number
ESPA1-4040
Salt Rejection
Configuration
99.3 % (99.0 %
Minimum)
Spiral Wound
85 ft2 (7.9m2)
pH Range, Continuous
(Cleaning)
2-10 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values
may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for
more detail on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
150 psi (1.05 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
(Data taken after 30 minutes of operation)
A, inches (mm)
40.0 (1016)
B, inches (mm)
3.95 (100.3)
C, inches (mm)
0.75 (19.1)
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
251
Part Number
ESPA2-4040
Salt Rejection
Configuration
99.6 % (99.4 %
Minimum)
Spiral Wound
85 ft2 (7.9m2)
pH Range, Continuous
(Cleaning)
2-10 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure
the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on
operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
150 psi (1.05 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
(Data taken after 30 minutes of operation)
A, inches (mm)
40.0 (1016)
B, inches (mm)
3.95 (100.3)
C, inches (mm)
0.75 (19.1)
252
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Part Number
ESPA2-LD-4040
Permeate Flow
Salt Rejection
Configuration
Polymer
Active Area:
Feed Spacer:
99.6 % (99.4 %
Minimum)
Composite
Polyamide
pH Range, Continuous
(Cleaning)
2-11 (1-13)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
150 psi (1.05 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
3.95 (100.3)
C, inches (mm)
0.75 (19.1)
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
253
Part Number
ESPA3-4040
Salt Rejection
Configuration
98.5 % (98.0 %
Minimum)
Spiral Wound
85 ft2
pH Range, Continuous
(Cleaning)
2-10 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
150 psi (1.05 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
(Data taken after 30 minutes of operation)
A, inches (mm)
40.0 (1016)
B, inches (mm)
3.95 (100.3)
C, inches (mm)
0.75 (19.1)
254
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Part Number
CPA2-4040
Salt Rejection
Configuration
99.5 % (99.2%
minimum)
Spiral Wound
pH Range, Continuous
(Cleaning)
2-10 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
225 psi (1.55 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.00 (1016)
B, inches (mm)
3.95 (100.3)
C, inches (mm)
0.75 (19.1)
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
255
Part Number
Permeate Flow
Salt Rejection
CPA5-LD-4040
99.7 % (99.5%
minimum)
pH Range, Continuous
Membrane Polymer Membrane Active
Feed Spacer:
Area
(Cleaning)
Low Fouling Spiral
Composite
34 mil (0.864 mm)
80 ft2 (7.43 m2)
2-11 (1-13)*
Wound
Polyamide
with biostatic agent
Configuration
* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure
the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on
operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
225 psi (1.55 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
3.95 (100.3)
C, inches (mm)
0.75 (19.1)
256
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Part Number
Permeate Flow
Salt Rejection
ESPA2-LD
99.6 % (99.5 %
minimum)
Configuration
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
150 psi (1.05 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary + or - 15 percent. Membrane active area may vary +/-4%. All membrane elements
are supplied with a brine seal, interconnector, and o-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0%
sodium meta-bisulfite solution, and then packaged in a cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good
faith, but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for
results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine
the appropriateness of Hydranautics' products for the user's specific end uses.
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
257
Part Number
Permeate Flow
Salt Rejection
ESPA2 MAX
99.6 % (99.5 %
minimum)
Boron Rejection
(Typical)@ pH = 10
93.0 %
Configuration
Spiral Wound
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
150 psi (1.05 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary + or - 15 percent. Membrane active area may vary +/-4%. All membrane elements
are supplied with a brine seal, interconnector, and o-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0%
sodium meta-bisulfite solution, and then packaged in a cardboard box. All elements are guaranteed 99.5% minimum rejection.
When tested at standard test conditions with 5.0ppm Boron in feed solution.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good
faith, but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for
results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine
the appropriateness of Hydranautics' products for the user's specific end uses.
258
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Part Number
ESPA4
Salt Rejection
Configuration
99.2 % (99.0 %
minimum)
Spiral Wound
pH Range, Continuous
(Cleaning)
2-10 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
500 PPM NaCl solution
100 psi (0.7 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary + or - 15 percent. Membrane active area may vary +/-4%. All membrane elements
are supplied with a brine seal, interconnector, and o-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0%
sodium meta-bisulfite solution and 10% propylene glycol, and then packaged in a cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good
faith, but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for
results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine
the appropriateness of Hydranautics' products for the user's specific end uses.
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
259
Part Number
ESPA4 MAX
Salt Rejection
Configuration
99.2 % (99.0 %
minimum)
Spiral Wound
Composite Polyamide
pH Range, Continuous
(Cleaning)
2-10.6 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
500 PPM NaCl solution
100 psi (0.7 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary + or - 15 percent. Membrane active area may vary +/-4%. All membrane elements are
supplied with a brine seal, interconnector, and o-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium
meta-bisulfite solution and 10% propylene glycol, and then packaged in a cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith,
but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results
obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the
appropriateness of Hydranautics' products for the user's specific end uses. 11/12/10
260
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Part Number
Permeate Flow
Salt Rejection
Configuration
CPA3
99.7% (99.6%
minimum)
Spiral Wound
Feed Spacer:
31 mil (0.787mm)
pH Range, Continuous
(Cleaning)
2-10.8 (1-12.5)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
225 psi (1.55 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary 15 percent. Membrane active area may vary +/-4%. All membrane elements are
supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium
meta-bisulfite solution, and then packaged in a cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith,
but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results
obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the
appropriateness of Hydranautics' products for the user's specific end uses.
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
261
Part Number
Permeate Flow
Salt Rejection
CPA5-LD
99.7 % (99.6 %
minimum)
pH Range, Continuous
Membrane Polymer Membrane Active
Feed Spacer:
Area
(Cleaning)
Low Fouling Spiral
Composite
34 mil (0.864 mm)
400 ft2 (37.1m2)
2-11 (1-13)*
Wound
Polyamide
with biostatic agent
Configuration
* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure
the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on
operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
225 psi (1.55 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary 15 percent. Membrane active area may vary +/-4%. All membrane elements are
supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium
meta-bisulfite solution, and then packaged in a cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith,
but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results
obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the
appropriateness of Hydranautics' products for the user's specific end uses.
262
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Part Number
CPA5 MAX
Salt Rejection
Configuration
99.7 % (99.6%
minimum)
Spiral Wound
Nominal Membrane
Area:
Composite Polyamide
440 ft2 (40.9 m2)
Membrane Polymer
pH Range, Continuous
(Cleaning)
2-11 (1-13)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure
the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on
operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1,500 ppm NaCl
225 psi (1.55 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary + or - 15 percent. All membrane elements are supplied with a brine seal, interconnector,
and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a
cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith, but
without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results obtained
or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the appropriateness
of Hydranautics' products for the user's specific end uses.
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
263
CaCl2 Rejection:
CaCl2 Rejection (minimum/maximum)
89%
86%/95%
* Expected calcium rejection for a typical 500 ppm well water is 93% at 13 gfd operating flux and 25 C.
Application Data *
Part Number
Permeate Flow
Configuration
ESNA1-LF-LD
Feed Spacer:
34 mil (0.864 mm) with
biostatic agent
pH Range, Continuous
(Cleaning)
2-10 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure
the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on
operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
500 ppm CaCl2
75 psi (0.52 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 7.0 Feed pH
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary -20/+25 percent. Membrane active area may vary +/-4%. All membrane elements are
supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium
bisulfite solution, and then packaged in a cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith,
but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results
obtained or damages incurred through the application of the presented information and data. It is the users responsibility to determine the
appropriateness of Hydranautics products for the users specific end uses.
264
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
CaCl2 Rejection:
CaCl2 Rejection (minimum/maximum)
86%
83%/90%
* Expected calcium rejection for a typical 500 ppm well water is 93% at 13 gfd operating flux and 25 C.
Application Data *
Part Number
Permeate Flow
Configuration
ESNA1-LF2-LD
Feed Spacer:
34 mil (0.864 mm) with
biostatic agent
pH Range, Continuous
(Cleaning)
2-10 (1-12)*
* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure
the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on
operation limits, cleaning pH, and cleaning temperatures.
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
500 ppm CaCl2
75 psi (0.52 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 7.0 Feed pH
A, inches (mm)
40.0 (1016)
B, inches (mm)
7.89 (200)
C, inches (mm)
1.125 (28.6)
Notice: Permeate flow for individual elements may vary -20/+25 percent. Membrane active area may vary +/-4%. All membrane elements are
supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium
bisulfite solution, and then packaged in a cardboard box.
Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith,
but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results
obtained or damages incurred through the application of the presented information and data. It is the users responsibility to determine the
appropriateness of Hydranautics products for the users specific end uses.
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
265
EP Ultrafiltration
Spiral Elements
Polyvinylidene Fluoride (PVDF) Membrane
with Extended Life and Superior Chemical
Resistance
Designed for extended life in a wide
range of industrial and electrocoat
applications, EP Ultrafiltration Spiral
Elements provide greater resistance to
fouling by colloidal particles and oily
contamination. The Polyvinylidene
Fluoride (PVDF) membrane provides
excellent chemical and temperature
resistance under a variety of process
conditions.
Benefits
Available in sealed (low flow) or netted
(high flow) design
Membrane has no electrical charge and can
be used on either Anodic or Cathodic
electrocoat paints
Resistant to fouling due to contamination or color pigments
Element construction developed for extended life in industrial
applications
Available in standard diameter or custom sized configurations for
maximum performance and optimal cleaning
Increased resistance to oxidizing cleaning agents
Available in many configurations to
retrofit competitive elements
Materials of Construction:
Membrane
Polyvinylidene Fluoride
Backing Material Polyester
Permeate Tube
Polyvinyl Chloride (PVC)
Seal Carrier
ABS Plastic
Brine Seal
EPDM
266
Applications
Anodic/Cathodic Paint
Select Water Borne Paints
Waste Water Recycle
Alkaline Cleaner Recovery
PVA Recovery
Operating Limits/Conditions:
Maximum Inlet Pressure
Typical Inlet Pressure
Maximum Operating Temperature
pH Range, continuous
pH Range, short-term cleaning
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Description
Taped element for a PAF PMC-1812-HSG housing
Taped element for a PAF2R2514 series housing
Taped element for a PAF2R2521 series housing
Sealed element for PAF2R4028 & 1VUF30 series PVC housing
Sealed element for PAF 2R4033 series PVC housing /Koch 4 retrofit
Netted element for PAF1VUF40 series PVC housing or SS housing
Sealed element for Osmonics 4" SS housing
Sealed element for Osmonics 4" SS housing (Reinforced Construction)
Sealed element for PAF 2R4040 series PVC housing
Sealed element for PAF 2R40SP series PVC housing (Filmtec Style)
Sealed element for PAF 2R4045 & 1VUF50 series PVC housing
Sealed element for 6" PAF 2VUF60 series PVC housing
Netted element for 6" PAF 2VUF60 series PVC housing /Synder 6" retrofit
Sealed element for Synder 6" housing
Netted element for Koch 6" PVC housing
Sealed element for Koch 8" PVC housing
Sealed for new style PAF 2VUF80 series PVC or SS housing
Sealed for older PAF 2VUF80 series PVC housing
Sealed element for PAF 2VUF80 series PVC housing -with double seal ATD
Netted element for 8" PAF 2VUF80 series PVC housing Synder 8" retrofit
Sealed element for 8" Synder PVC /SS housing
Netted element for Osmonics 8" SS40 housing
Sealed element for Hydranautics 8" housing
Sealed element for Osmonics 8" SS10 housing
Sealed element for Osmonics 8" SS40 housing
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Diameter
(in)
(cm)
1.80
4.6
2.41
6.1
2.41
6.1
3.88
9.9
3.88
9.9
3.88
9.9
3.88
9.9
3.88
9.9
3.88
9.9
3.88
9.9
3.88
9.9
5.45
13.8
5.90
15.0
5.45
13.8
6.30
16.0
7.48
19.0
7.28
18.5
7.28
18.5
7.48
19.0
7.6
19.3
7.48
19.0
7.90
20.1
7.90
20.1
8.27
21.0
7.90
20.1
Overall Length
(in)
(cm)
12.0
30.5
14.0
35.6
21.0
53.3
28.0
71.1
33.0
83.8
40.0
101.6
40.0
101.6
40.0
101.6
40.0
101.6
40.0
101.6
45.0
114.3
40.0
101.6
40.0
101.6
47.5
120.7
39.0
99.1
37.0
94.0
40.0
101.6
40.0
101.6
40.0
101.6
40.0
101.6
47.5
120.7
40.0
101.6
40.0
101.6
40.0
101.6
40.0
101.6
Sales@tfsi1.com
www.tfsi1.com
Area
(ft2) (m2)
3.4
0.3
5.5
0.5
10.9
1.0
47
4.4
57
5.3
75
7.0
75
7.0
70
6.5
70
6.5
72
6.7
81
7.5
153
14.2
153
14.2
180
16.7
162
15.1
218
20.3
278
25.8
278
25.8
278
25.8
278
25.8
317
29.5
333
30.9
341
31.7
389
36.1
344
31.7
267
268
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Membrane Polymer
PES
PES
PES
PES
PES
PES
PES
PVDF
PVDF
PVDF
PVDF
PVDF
PVDF
PVDF
PVDF
PVDF
PVDF
PVDF
PVDF
Common Applications
Color Removal, Antibiotics, Protein & Polypeptide
Antibiotics, Pharmaceuticals, Protein & Polypeptide
Whey Protein (WPC/WPI), Enzyme Concentration
WPC/WPI, Gelatin, Beverage Clarification, Enzyme
Skim Milk Protein (MPC/MPI), Beverage Clarification
Corn Wet Milling
Corn Wet Milling
Alkaline Cleaner, Industrial Waste Water
Industrial Waste Water
Industrial Waste Water
Cathodic Electrocoat Paint, Industrial Waste Water
Laundry Waste Water, Industrial Waste water
Brine clarification, Protein Concentration
Corn Wet Milling, Microbial/Particle Removal
Corn Wet Milling, Microbial/Particle Removal
Anodic Electrocoat Paint, Pigments, Microbial Removal
Fat, Microbial Removal, Protein Fractionation
Microbial Removal, Protein Fractionation
Microbial Removal, Enzyme Clarification
Sales@tfsi1.com
www.tfsi1.com
Model #
2519H
2540H
3940H
4040HA
4037H
4051.5H
5640H
5647.5H
5651.5H
7637H
7640H
7647.5H
7940HA
F7940HA
8040HA
8040HB
A
LENGTH
19.25 (489)
40.0 (1016)
38.8 (986)
40.0 (1016)
27.0 (686)
40.0 (1016)
40.0 (1016)
40.0 (1016)
40.0 (1016)
40.0 (1016)
40.0 (1016)
40.0 (1016)
40.0 (1016)
40.0 (1016)
38.28 (972)
40.0 (1016)
C
TUBE EXT
LENGTH (MALE)
1 (both ends)
0.6 (both ends)
3 (perm); 8.63 (plug)
3 (perm); 8.5 (plug)
3 (perm); 8.375 (plug)
3 (perm); 4.375 (plug)
2 (both ends)
3 (perm); 4.375 (plug)
0.875 (both ends)
3 (perm only)
-
3.0 (1.4)
4.0 (1.8)
11.0 (5.0)
11.0 (5.0)
10.0 (4.5)
12.0 (5.5)
30.0 (13.6)
28.0 (12.7)
30.0 (13.6)
38.0 (17.2)
38.0 (17.2)
42.0 (19.1)
42.0 (19.1)
40.0 (18.1)
41.0 (18.6)
41.0 (18.6)
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
269
UF ELEMENTS
270
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Synders Mobile Clean-In-Place (CIP) System offers an economical solution to extend UF life and maximize permeate
output. Mobile CIP Systems can also be used to clean RO Systems and other e-coat related equipment.
Pump, Tank, Flow Meter & Instruments included.
Bag Filter Housing can be installed upon request
Epoxy-Coated Carbon Steel Frame on Casters
Heating Element and/ or Cooling Coil can be installed
upon request
Small One Square Meter footprint
UFCC
Ultrafiltration Compatibility Coefficient (UFCC) evaluation is a
series of tests that compare UF performance against a multitude
of paint conditions. In the first phase, acid concentration (meq/L)
is measured and it is determined if further testing is required. In
many cases, simply adjusting the acid concentration can provide
significant improvements to UF flux stability.
In the second phase, bath paint is compared to fresh paint and a
UFCC number is determined on a scale of 0 1. The higher the
UFCC number, the better the UF performance. Eg. Lower frequency of cleaning, greater permeate output overtime,
and possibly longer membrane life. If a UFCC number is considered too low for economical operation of UF
elements, adjustments will be made to the bath paints acid concentration until an acceptable UFCC number is
reached. If acid adjustment alone can not improve UFCC sufficiently, a third phase of testing can be done.
UFCC
CLEANING FREQUENCY
The third phase involves testing of other contaminants
such as bacteria, phosphate, and pre-treatment cleaners.
0.95 and up Generally no cleaning is required
Once the problem is determined, further testing is done
0.80 - 0.95
Cleaning required 1 to 2 times per year
to identify possible solutions. In the end, a
recommendation is made based on all gathered data and 0.70 - 0.80
Cleaning required 4-5 times a year
this recommendation is shared with both the paint
0.60 - 0.70
Cleaning required once a month
maker and end user. All UFCC tests require good
Cleaning required twice a month
communication between the paint maker, end user, and 0.50 - 0.60
Synder Filtration. Detailed record keeping of tank
Less than 0.50 UF operation practically impossible
history, operating conditions, and UF performance are
absolutely essential to the UFCC process.
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
271
LEMENTSUM04 11/08
Part Number
1812
2012
2514
2540
3833
3838.75
3838
3840
4038
4040
4338
4340
6338
8038
8040
8338
8340
LENGTH (in)
31 mil (ft2)
46 mil (ft2)
65 mil (ft2)
80 mil (ft2)
12
12
14
40
33
38.75
38
40
38
40
38
40
38
38
40
38
40
3.6
3.6
6
16
65
76
75
75
80
80
90
90
205
310
310
350
350
2.9
2.9
4.8
13
52
61
60
60
65
65
75
75
165
260
260
280
280
2.2
2.2
3.7
10
39
45
45
45
50
50
52
52
165
210
210
230
230
1.8
1.8
3
8
32
37
37
37
40
40
42
42
100
170
170
180
180
CONSTRUCTION OPTIONS
PERMEATE TUBE
MATERIAL
ABS
CPVC
Polysulfone
304SS
272
ADHESIVE
Urethane
Epoxy
FEED SPACER
OUTER WRAP
SPECIAL
CONSTRUCTION
Sanitary/Net
Fiber Reinforced Plastic (FRP)
Net over FRP
High Pressure
High Temperature
Custom Configuration
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Product Description
Flocon MC10 is a powdered high pH cleaner
specifically formulated to remove organics, silt and
other particulate deposits from polyamide,
polysulfone, and thin film composite
membrane surfaces.
This advanced, high strength cleaner has the
following features:
Typical Properties
The following are typical properties for Flocon
MC10 and should not be regarded as specification
limits for the product.
A product specification is available on request.
Appearance
Odor
pH (1% solution)
Bulk Density
4
6
8
10
12
6
14
24
30
54
Description
Plastic pails
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
23
53
91
114
204
Net Weight
50 lbs
Gross Weight
53 lbs
Sales@tfsi1.com
www.tfsi1.com
273
Product Description
Flocon MC15 is a liquid high pH cleaner specifically
formulated to remove organics, silt and other
particulate deposits from polyamide, polysulfone,
and thin film composite membrane surfaces.
This advanced, high strength cleaner has the
following features:
Typical Properties
The following are typical properties for Flocon
MC15 and should not be regarded as specification
limits for the product. A product specification is
available on request.
Appearance
Odor
pH (1% solution)
Specific Gravity
amber liquid
slight
> 12
1.1
274
4
6
8
10
12
6
14
24
30
54
Description
Plastic pail
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
23
53
91
114
204
Net Weight
45 lbs
Gross Weight
48 lbs
Sales@tfsi1.com
www.tfsi1.com
Product Description
Flocon MC20 is a powdered acid pH cleaner
specifically formulated to dissolve and remove
inorganic scales from polyamide, polysulfone, and
thin film composite membrane surfaces. These scales
include, but are not limited to carbonates, iron, and
manganese fouling/deposits.
This advanced, high strength cleaner has the
following features:
Typical Properties
The following are typical properties for Flocon
MC20 and should not be regarded as specification
limits for the product.
A product specification is available on request.
Appearance
Odor
pH (1% solution)
Bulk Density
4
6
8
10
12
6
14
24
30
54
Description
Plastic pail
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
23
53
91
114
204
Net Weight
50 lbs
Gross weight
53 lbs
Sales@tfsi1.com
www.tfsi1.com
275
Product Description
Flocon MC25 is a liquid acid pH cleaner specifically
formulated to dissolve and remove inorganic scales
from polyamide, polysulfone, and thin film composite
membrane surfaces. These scales include, but are not
limited to carbonates, iron, and manganese
fouling/deposits.
This advanced, high strength cleaner has the following
features:
Typical Properties
The following are typical properties for Flocon MC25
and should not be regarded as specification limits for
the product. A product specification is available on
request.
Appearance
Odor
pH (1% solution)
Specific Gravity
Part Number
FLOMC25-5
276
4
6
8
10
12
23
53
91
114
204
Description
Plastic Pail
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
6
14
24
30
54
Net Weight
55 lbs
Gross Weight
57 lbs
Sales@tfsi1.com
www.tfsi1.com
Product Description
Flocon 135 is an aqueous solution of a
specialized phosphinocarboxylic acid, highly
effective in controlling the deposition of
inorganic scale-forming salts on membrane
surfaces.
Typical Properties
The following are typical properties for Flocon
135 and should not be regarded as specification
limits for the product. A product specification is
available on request.
Appearance
pH
Specific gravity at 20/20oC
Freezing point range
Chemical Reactivity
Flocon 135 is not affected by chlorine or other
oxidizing biocides under normal conditions of
use. Flocon 135 may be used in membrane
systems using chlorine and sodium
metabisulphite.
Part Number
FLO135-5
FLO135-55
FLO135-275
Description
Plastic drums
Plastic drums
Intermediate Bulk Containers
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Net Weight
55 lbs
507 lbs
2205 lbs
Sales@tfsi1.com
www.tfsi1.com
277
Product Description
Flocon 260 is an aqueous solution of a specialized
polycarboxylic acid, highly effective in controlling
the deposition of inorganic scale forming salts and
particulate fouling on membrane surfaces.
Typical Properties
The following are typical properties for Flocon 260
and should not be regarded as specification limits
for the product. A product specification is available
on request.
Appearance
pH
Specific gravity at 20/20C
Freezing point range
Chemical Reactivity
Flocon 260 is not affected by chlorine or other
oxidising biocides under normal conditions of use.
Flocon 260 may be used in membrane systems
using chlorine and sodium metabisulphite.
Part Number
FLO260-6
FLO260-55
FLO260-275
278
Description
Plastic drums
Plastic drums
Intermediate Bulk Containers
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Net Weight
55 lbs
507 lbs
2205 lbs
Sales@tfsi1.com
www.tfsi1.com
General Properties
Typical Applications
Process ingredient water
Rinse water
Food ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Standard Economy Features (ECN)
Low-energy design reduces electrical requirements and
operating costs
RO Save.Zs, 1 micron pre-filter
Automatic inlet shut-off valve
Permeate and Concentrate flow meters
Remote machine on/off capability
Thermal Motor Protection
Pre-filter, post-filter, primary, and final pressure gauges
Flow control center including concentrate and recycle
valves
Deluxe (DLX) Features --- In addition to ECN
Features
Auto flush system
Low inlet pressure switch
Digital conductivity meter
Alarms: Low Inlet Pressure, Motor Starter overload
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
279
E4-4400
E4-6600
E4-8800
E4-11000
E4-13200
ECN
DLX
Model
1230850
1230852
1230855
1230856
1230859
1230860
1230863
1230864
1230867
1230868
1230871
1230871
Recovery Range:
Permeate Rate:
gpm (m3/h)
Concentrate Rate:
gpm (m3/h)
50-75%
1.5 (0.3)
50-75%
3 (0.7)
50-75%
4.5 (1.0)
50-75%
6 (1.4)
50-75%
7.5 (1.7)
50-75%
9 (2.1)
1.5-0.5
(0.3-0.1)
3.0-1.0
(0.7-0.2)
4.5-1.5
(1-0.3)
6.0-2.0
(1.4-0.5)
7.5-2.5
(1.7-0.6)
9.0-3.0
(2.1-0.7)
Pump Model
Motor: HP (KW)
SS1809X
1.5 (1.1)
SS1809X
1.5 (1.1)
SS1809X
1.5 (1.1)
SS1812X
2 (1.5)
SS1812X
2 (1.5)
4
1-1-1-1
5
2-1-1-1
6
2-2-1-1
0.75 (1.9)
0.75 (1.9)
0.75 (1.9)
0.75 (1.9)
0.75 (1.9)
0.75 (1.9)
0.75 (1.9)
0.75 (1.9)
0.75 (1.9)
Flow Specifications
Membrane Elements
Quantity
Array
1
1
2
1-1
3
1-1-1
0.75 (1.9)
0.5 (1.3)
0.5 (1.3)
0.75 (1.9)
0.5 (1.3)
0.5 (1.3)
Connections
Inlet: inch (cm)
Permeate: inch (cm)
Concentrate: inch (cm)
0.75 (1.9)
0.5 (1.3)
0.5 (1.3)
280
50 (127)
30 (76)
20 (51)
50 (127)
30 (76)
20 (51)
55 (139)
30 (76)
20 (51)
55 (139)
30 (76)
26 (66)
60 (152)
30 (76)
26 (66)
60 (152)
30 (76)
26 (66)
170 (77)
185 (83)
215 (98)
235 (107)
325 (147)
345 (156)
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
General Properties
Figure 1: E4H Series 60 Hz
Typical Applications
Process ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Operating Pressure
Maximum Recovery
Nominal Rejection
Operating Temperature
Minimum Inlet Pressure
Design Temperature
Sales@tfsi1.com
www.tfsi1.com
281
ECN
DLX
ECN
DLX
E4H-16K
E4H-21K
E4H-27K
E4H-38K
E4H-43K
1163775
1200054
1163776
1200055
1163781
1200060
1163782
1200061
1163787
1200066
1163788
1200067
1163793
1200072
1163794
1200073
1163796
1200075
1163797
1200076
75%
18.8 (4.3)
6.3 (1.4)
75%
26.2 (5.9)
8.8 (2.0)
75%
30 (6.8)
10.0 (2.3)
SS2828D
10 (7.4)
SS2805AZ
2 (1.5)
SS5512KA
15 (11.2)
SS5503G
5 (3.7)
SS5512KA
15 (11.2)
SS5503G
5 (3.7)
1.5 (3.8)
1 (2.5)
1 (2.5)
1.5 (3.8)
1 (2.5)
1 (2.5)
1.5 (3.8)
1 (2.5)
1 (2.5)
1.5 (3.8)
1 (2.5)
1 (2.5)
1.5 (3.8)
1 (2.5)
1 (2.5)
1.5 (3.8)
1 (2.5)
1 (2.5)
Flow Specifications
Recovery Range:
Permeate Rate: gpm (m3/h)
Concentrate Rate: gpm (m3/h)
75%
11.2 (2.56)
3.4 (0.9)
RO Pump Model
RO Motor: HP (KW)
CIP Pump Model: (DLX only)
CIP Motor: HP (KW)
SS2823G
7.5 (5.6)
SS2805AZ
2 (1.5)
75%
15 (3.4)
5.0 (1.1)
9
2-1
2
12
2-2
2
Connections
Inlet: inch (cm)
Permeate: inch (cm)
Concentrate: inch (cm)
1.5 (3.8)
1 (2.5)
1 (2.5)
1.5 (3.8)
1 (2.5)
1 (2.5)
62 (158)
132 (335)
36 (92)
62 (158)
132 (335)
36 (92)
62 (158)
132 (335)
36 (92)
62 (158)
132 (335)
36 (92)
62 (158)
132 (335)
36 (92)
Shipping Weight
Estimate: lb (kg)
ECN
1000 (500)
1050 (500)
1550 (700)
1700 (800)
1800 (820)
Shipping Weight
Estimate: lb (kg)
DLX
11500 (530)
1250 (570)
1750 (800)
1900 (870)
2000 (910)
282
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
Figure 1: E8 Series 60 Hz
General Properties
Typical Applications
Process ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Standard Economy Features
Energy saving 400 ft2 (37.2 m2) membrane elements
SS high-pressure piping
1-micron pre-filter and SS housing
Automatic inlet shut-off valve
Accutrak* RO microprocessor controller
Permeate and concentrate paddlewheel flow sensors
Permeate conductivity sensor
Permeate tank level monitoring
SD card for collection of operating data
ALARMS: Low inlet pressure, high concentrate pressure,
high temperature, high permeate conductivity, motor
fault, and fill-time exceeded
Remote machine on/off capability
Feed water flush on shutdown
Panel-mounted pre-filter, post-filter, primary, and final
pressure gauges
Deluxe (DLX) Features --- In addition to ECN
Features
Inlet pH sensor
Chemical dosing pump for antiscalant dosing or pH
adjustment
Clean-In-Place pump plumbed, wired and mounted;
remote tank
ALARMS: Same as above plus high/low inlet pH, high
permeate pressure
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
283
E8-57K`
E8-86K
E8-108K
E8-144K
1202846
1202833
1202284
1202287
1202850
1202835
1202286
1202288
66-75%
75 (17)
39-25 (9-6)
66-75%
100 (23)
52-33 (12-8)
Flow Specifications
Recovery Range:
Permeate Rate: gpm (m3/h)
Concentrate Rate: gpm (m3/h)
66-75%
40 (9)
21-13 (5-3)
66-75%
60 (14)
30-20 (7-5)
RO Pump Model
RO Motor: HP (KW)
SS8510KA
15 (11.2)
SS8512KB
20 (15)
SS8512KB
25 (18.7)
SS24006KE
40 (29.8)
SS5504G
5 (3.7)
SS5504G
5 (3.7)
SS8504G
7.5 (5.6)
SS8504G
7.5 (5.6)
12
15
21
Array
Pre-Filter Quantity
1-1-1
7, RO.Zs 01-40-XK
2-1-1
7, RO.Zs 01-40-XK
3-2
7, RO.Zs 01-40-XK
3-2-2
7, RO.Zs 01-40-XK
2.0 (5.1)
2.0 (5.1)
1.5 (3.8)
3.0 (7.6)
2.0 (5.1)
1.5 (3.8)
Connections
Inlet: inch (cm)
Permeate: inch (cm)
Concentrate: inch (cm)
2.0 (5.1)
1.5 (3.8)
1.5 (3.8)
2.0 (5.1)
2.0 (5.1)
1.5 (3.8)
76 (193)
153 (388)
42 (107)
91 (231)
76 (193)
153 (388)
42 (107)
91 (231)
76 (193)
153 (388)
42 (107)
91 (231)
76 (193)
153 (388)
42 (107)
103 (262)
ECN
2600 (1200)
3000 (1360)
3400 (1500)
3800 (1750)
DLX
2800 (1300)
3300 (1500)
3700 (1700)
4200 (1900)
284
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
ANOCELTM-TCF
T-1500 and T-2000 series tubular cells for
both cathodic and anodic E-coat applications
SPECIFICATIONS
Materials of construction
Heavy-duty PVC body; rigid polypropylene mesh
membrane protector
Electrode
The anodes and cathodes are supplied with 316L
stainless steel.
TYPE
ANODE DIAMETER
EFFECTIVE AREA
T-1500
T-2000
(1-7/8)
(2-3/8)
Membrane
Pre-expanded resin based ion exchange membrane.
Welded construction.
Available for cathodic and anodic paints.
Dimensions
Maximum shell outer diameter
T-1500
3.5 (89 mm)
T-2000
4.5 (114 mm)
Standard lengths available in a range of sizes up to 12
(366 cm)
Accessories
Flow meters with valve
Supply and return tubing
Mounting clamps
Appropriate inlet/outlet connections, i.e., hose
inlet/outlet fittings
Electrical connection
Quick disconnect electrical connection
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
BENEFITS
Sales@tfsi1.com
www.tfsi1.com
285
286
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Optional configurations
Submersible floor and overhead electrodes (see notes)
Bare electrodes
RuO and Iridium
Notes:
Tubular overhead cells: same features as the side cell
version; is available in custom sizes for any
application. All units are supplied complete with
mounting hardware and instructions.
Sales@tfsi1.com
www.tfsi1.com
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com
287
288
Corporate Office:
2725 Commerce Parkway
Auburn Hills, MI 48326
Sales@tfsi1.com
www.tfsi1.com