Vous êtes sur la page 1sur 6

Profis Anchor 2.6.

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Fastening Point:
Date:

1
Heybridge - Cylinder T
19/01/2016

Specifier's comments:

1 Input data
Anchor type and size:

HIT-HY 200-A + Rebar 25mm

Seismic/Filling set or any suitable annular gap filling solution


Effective embedment depth:

hef,act = 500 mm (hef,limit = - mm)

Material:

B500B

Approval No.:

ETA 11/0493

Issued I Valid:

15/04/2015 | 15/04/2020

Proof:

Design method Engineering judgement SOFA BOND - based on ETAG BOND testing

Stand-off installation:

eb = 0 mm (no stand-off); t = 12 mm

Baseplate:

lx x ly x t = 915 mm x 2286 mm x 12 mm; (Recommended plate thickness: not calculated

Profile:

Rectangular hollow; (L x W x T) = 600 mm x 700 mm x 3 mm

Base material:

cracked concrete, C20/25, fc = 25.00 N/mm2; h = 1400 mm, Temp. short/long: 0/0 C

Installation:

hammer drilled hole, Installation condition: Dry

Reinforcement:

No reinforcement or Reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.6.2

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

2
Heybridge - Cylinder T

Page:
Project:
Fastening Point:
Date:

19/01/2016

2 Load case/Resulting anchor forces


1

Load case: Design loads

2
y

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Tension force
Shear force
Shear force x
Anchor
1
65.813
0.000
0.000
2
45.096
0.000
0.000
3
63.206
0.000
0.000
4
42.489
0.000
0.000
5
55.011
0.000
0.000
6
34.294
0.000
0.000
7
52.404
0.000
0.000
8
31.687
0.000
0.000
max. concrete compressive strain:
- []
max. concrete compressive stress:
- [N/mm2]
resulting tension force in (x/y)=(50/85):
390.000 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]

3
Shear force y
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Tension

3 Tension load (EOTA TR 029, Section 5.2.2)


Load [kN]
65.813

Capacity [kN]
192.857

Utilisation bN [%]
35

Status
OK

Combined pullout-concrete cone failure**

390.000

772.747

51

OK

Concrete cone failure**

390.000

421.509

93

OK

Splitting failure**

390.000

963.734

41

OK

Steel failure*

* most unfavourable anchor

**anchor group (anchors in tension)

3.1 Steel failure


NRk,s [kN]
270.000

gM,s
1.400

NRd,s [kN]
192.857

NSd [kN]
65.813

3.2 Combined pullout-concrete cone failure


Ap,N [mm2]
2028683

A0p,N [mm2]
400000

2
tRk,ucr,25 [N/mm ]
12.00

scr,Np [mm]
632

ccr,Np [mm]
316

yc
1.000

2
tRk,cr [N/mm ]
7.00

k
2.300

yg,Np
1.802

yg,Np
1.089

ec1,N [mm]
42

yec1,Np
0.882

ec2,N [mm]
85

yec2,Np
0.866

ys,Np
1.000

N0Rk,p [kN]
274.889

NRk,p [kN]
1159.121

gM,p
1.500

NRd,p [kN]
772.747

NSd [kN]
390.000

cmin [mm]
350

yre,Np
1.000

3.3 Concrete cone failure


Ac,N [mm2]
4950000

A0c,N [mm2]
2250000

ccr,N [mm]
750

scr,N [mm]
1500

ec1,N [mm]
42

yec1,N
0.946

ec2,N [mm]
85

yec2,N
0.898

N0Rk,c [kN]
402.492

gM,c
1.500

NRd,c [kN]
421.509

NSd [kN]
390.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

ys,N
0.840

yre,N
1.000

k1
7.200

Profis Anchor 2.6.2

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

3
Heybridge - Cylinder T

Page:
Project:
Fastening Point:
Date:

19/01/2016

3.4 Splitting failure


Ac,N [mm2]
3375000

A0c,N [mm2]
1000000

ccr,sp [mm]
500

scr,sp [mm]
1000

yh,sp
1.465

ec1,N [mm]
42

yec1,N
0.922

ec2,N [mm]
85

yec2,N
0.866

ys,N
0.910

N0Rk,c [kN]
402.492

gM,sp
1.500

NRd,sp [kN]
963.734

NSd [kN]
390.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

yre,N
1.000

k1
7.200

Profis Anchor 2.6.2

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

4
Heybridge - Cylinder T

Page:
Project:
Fastening Point:
Date:

19/01/2016

4 Shear load (EOTA TR 029, Section 5.2.3)


Load [kN]
N/A

Capacity [kN]
N/A

Utilisation bV [%]
N/A

Status
N/A

Steel failure (with lever arm)*

N/A

N/A

N/A

N/A

Pryout failure*

N/A

N/A

N/A

N/A

Concrete edge failure in direction **

N/A

N/A

N/A

N/A

Steel failure (without lever arm)*

* most unfavourable anchor

**anchor group (relevant anchors)

5 Displacements (highest loaded anchor)


Short term loading:
NSk

48.750 [kN]

VSk

0.000 [kN]

dN

0.137 [mm]

dV

0.000 [mm]

dNV

0.137 [mm]

dN

0.199 [mm]

dV

0.000 [mm]

dNV

0.199 [mm]

Long term loading:


NSk

48.750 [kN]

VSk

0.000 [kN]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

6 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!

Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Drilled hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
Characteristic bond resistances depend on short- and long-term temperatures.
The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling
the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
The compliance with current standards (e.g. EC3) is the responsibility of the user
An SLS-check is not performed for SOFA and has to be provided by the user!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.6.2

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

5
Heybridge - Cylinder T

Page:
Project:
Fastening Point:
Date:

19/01/2016

7 Installation data
Baseplate, steel: Profile: Rectangular hollow; 600 x 700 x 3 mm
Hole diameter in the fixture: df = 25 mm
Plate thickness (input): 12 mm
Recommended plate thickness: not calculated
Cleaning: Premium cleaning of the drilled hole is required

Anchor type and size: HIT-HY 200-A + Rebar 25mm


Installation torque: Hole diameter in the base material: 32 mm
Hole depth in the base material: 500 mm
Minimum thickness of the base material: 564 mm

7.1 Recommended accessories


Drilling
Suitable Rotary Hammer
Properly sized drill bit

Cleaning
Compressed air with required
accessories to blow from the bottom of
the hole
Proper diameter wire brush

Setting
Dispenser including cassette and mixer
For deep installations, a piston plug is
necessary
Seismic/Filling set
Torque wrench

y
50
458

243

458

1100

85

1143

350

1143

243

350

350

400

165

Coordinates Anchor [mm]


Anchor
1
2
3
4

x
-108
292
-108
292

y
900
900
550
550

c-x
350
750
350
750

c+x
-

c-y
2550
2550
2200
2200

c+y
750
750
1100
1100

Anchor
5
6
7
8

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

x
-108
292
-108
292

y
-550
-550
-900
-900

c-x
350
750
350
750

c+x
-

c-y
1100
1100
750
750

c+y
2200
2200
2550
2550

Profis Anchor 2.6.2

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Fastening Point:
Date:

6
Heybridge - Cylinder T
19/01/2016

8 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan