Feeder
. The antenna jumper and the feeder cable before the feeder
window must have waterproof bends.
support.huawei.com
Page 1
Feeder
. When the feeder cable is bent on the top of a building and then
extended downward along the wall, the protective means should
be used for the parts of contact with the wall corner. When the
feeder cable enter to room along the roof, the feeder clips should
be used to fix the feeder cable.
support.huawei.com
Page 2
support.huawei.com
Page 3
. The outside grounding bar must be wiped off rust and cleaned
dirt before they are connected, in order to ensure their reliable
connection. The outside grounding bar must be anticorrosion
and antirust processed by using self-spray paint or other
protection materials after they are connected in order to ensure
their long-term good contact. Each connecting terminal should
be installed correctly and firmly together with flat washers and
spring washers.
support.huawei.com
Page 4
. The feeder grounding clip is directly fixed on the steel sheet of the
tower perfectly. The installation of this clip must accord with the
standard requirement. The antirust, anticorrosive and waterproof
measures are adopted for the grounding clip and reliable connection.
support.huawei.com
Page 5
support.huawei.com
Page 6
Page 7
. If the length of feeder cable from the tower to the room on the
roof (or cabling ladder) is more than 20 meters, a lightningproof protection grounding clip should be added on the roof
(or cabling rack).
support.huawei.com
Page 8