Vous êtes sur la page 1sur 3

H.T.

MOTOR DATA SHEET


(To be furnished on the award of Contract)
Sr. No.

Description

01

Application

02

Existing Motor Manufacturer

03

Type and frame size & design code no.

04

Specification & Codes


Capacity for

05

i) for specified climatic conditions (500C)


ii) At 400C ambient

06

Location for installation

07

Type of enclosure & ventilation

08

Degree of protection

09

Type of duty

10

No. of phases, frequency & voltage

11

Permissible variations in
a) Voltage :
10%
b) Frequency
:
5%
c) Combined

12

At rated voltage & frequency


a) Full load current
:
79 A
b) Full load speed
:
990 RPM
c) No load current

13

Minimum permissible voltage during starting

14

Maximum permissible time at minimum Permissible


voltage during running at full load.
Efficiency & power factor
Load(% of full load)

15

100 %
75 %
50 %

Stator winding
Connection
ii)
Type & nos. of terminals Brought out
Starting current as % of full load current
17
16

18

Torque at full load in Kgm.

19

Break away torque in % of FLT

20

Pull up torque in % of FLT

21

Pull out torque in % of FLT

Particulars

Remark if any

Sr. No.

22

Description
Starting time in sec.(Note the type of coupling
mechanism Flexible / hydraulic)
i) with rated voltage
ii) with 85% of rated voltage
iii) with 110% of rated voltage

23

24

Insulation
i) Class of insulation
ii) Material & treatment of Insulation
Whether insulation is suitable
F,Limited to Class B temp. rise.
for ungrounded system

25

Method of starting

26

Permissible starting duty cycles

27

Maximum permissible voltage during high speed


suitably bus transfer & special design feature

28

29

30

31

32

33

34
35

Method of cooling
Details of water cooling system
Bearings
i. Number
ii.Type
iii.
Space Heaters
Machine Terminal designation corresponds to direction
of rotation (Facing driving end).
iii. Lubrication system
Terminal boxes with accessories separate terminal boxes
provided.
Type & Nos.
Mains
Winding temp. detectors
Bearing Temp. details.
Neutral terminals
Main terminal box details
i) Type & Nos.
ii) Location
iii) Cable gland size & no.
iv) Direction of cable entry.
Space Heater
Number
Location below winding Overhang
Capacity of each
Total power requirement
Voltage
Details of 4 wire RTDs required
i) Nos.
ii) Locations
Whether CTs for differential protection are
If Yes, no. of CTs supplied with motors.
a)
C.T. ratio.
b)
Accuracy Class.
c)
Knee point voltage.

Particulars

Remark if any

d)
S.C. withstand capacity.
e) Exciting Current at Vk / 2.

Sr. No.

Description

36

Type of mounting

37

Shaft orientation

38

Shaft extension

39

Grounding pads size nos. & location

40

Method of coupling to driven mechanism

41

Motor GD2

42

Rotor GD2

43

Noise Level

44

Vibration

Particulars

Remark if any

Drawings furnished
General arrangement of motor
45
ii) ii) Main terminal box showing the method of
terminating the Boards incoming cables
Specifications
as per IS
46
47

Motor characteristic curves.

Notes:1

User section shall try to furnish above data to get proper Motor from multivendor, if above data not
available, vendor technical team must visit at site to collect data.
a Motor technical data as mentioned above.
b Motor General arrangement drawing.
c Motor characteristic curves.

Vous aimerez peut-être aussi