Académique Documents
Professionnel Documents
Culture Documents
Innovations 2015/2016
RANTY
AR
www.ifm.com
on
ct
years
if m p r o d
Position sensors
Inductive sensors
TOP
TOP
(11.2015)
68-
7
9
(04.2015)
10 -
11
(04.2015)
12 -
13
(11.2015)
14 16 18 -
15
17
19
20 22 24 -
21
23
25
26 28 -
27
29
30 32 -
31
33
34 36 38 -
35
37
39
40 42 -
41
43
(11.2015)
44 46 -
45
47
(11.2015)
48 -
49
(11.2015)
Capacitive sensors
Capacitive touch sensors in compact M22 design
Magnetic sensors
TOP
(04.2015)
(11.2014)
(11.2014)
(11.2014)
(04.2015)
(04.2015)
(04.2015)
Inclination sensors
Robust and precise inclination sensors Now with IO-Link
Precision for all inclinations
(11.2015)
(11.2014)
(04.2015)
(04.2015)
(04.2015)
Industrial imaging
Camera systems for mobile machines
TOP
TOP
(11.2014)
(11.2014)
3D sensors
TOP
TOP
(11.2015)
3D cameras
TOP
Process sensors
Pressure sensors
TOP
TOP
(11.2015)
(04.2015)
(04.2015)
(11.2015)
50 52 54 56 -
51
53
55
57
58 60 62 64 -
59
61
63
65
66 68 70 72 74 -
67
69
71
73
75
76 78 80 82 84 -
77
79
81
83
85
86 88 -
87
89
90 92 -
91
93
94 96 98 -
95
97
99
(11.2015)
(04.2015)
(11.2015)
(04.2015)
Level sensors
TOP
TOP
(11.2015)
(11.2015)
(04.2015)
(04.2015)
(04.2015)
Temperature sensors
TOP
TOP
(11.2015)
(11.2015)
(04.2015)
(11.2014)
(11.2014)
Industrial communication
AS-Interface Safety at Work
TOP
(11.2015)
(11.2015)
IO-Link components
8-port IO-Link master: closing the gap in the field
IO-Link I/O module minimises wiring costs for sensors
(04.2015)
(04.2015)
System solutions
8-port IO-Link master module with LINERECORDER AGENT embedded
IO-Link The standard interface for smart sensors
Industry 4.0 made easy Apps instead of expensive programming
(04.2015)
(04.2015)
(11.2015)
Identification systems
RFID 125 kHz / RFID 13.56 MHz
RFID for mobile machines
Adapters to increase the ranges of the new RFID antennas
(11.2015)
100 - 101
102 - 103
(04.2015)
104 - 105
(11.2015)
1D / 2D code readers
Industrially-compatible multicode reader with text recognition
(04.2015)
106 - 107
108 - 109
110 - 111
(11.2015)
112 - 113
(11.2015)
114 - 115
116 - 117
(11.2015)
(04.2015)
Connection technology
Sockets
From factory automation to machine tool industry
The reliable connection even with strong noise field interference
(04.2015)
T splitters
For hygienic and wet areas in the food industry
The secure connection even in difficult applications
(11.2015)
118 - 119
120 - 121
(04.2015)
122 - 123
(11.2015)
Software
LINERECORDER SENSOR 4.0
Parameter setting software for IO-Link sensors
Position sensors
Position sensors
Inductive sensors
Type
Total length
Sensing range
[mm]
[mm]
Installation
Switching
frequency
[Hz]
Current rating
Order
number
2000
100
IFS289
[mA]
45
flush
M12
45
10
non-flush
2000
100
IFS290
M12
60
flush
2000
100
IFS285
M12
60
10
non-flush
2000
100
IFS286
M18
45
flush
2000
100
IGS279
M18
45
15
non-flush
2000
100
IGS280
M18
60
flush
2000
100
IGS277
M18
60
15
non-flush
2000
100
IGS278
M30
45
15
flush
2000
100
IIS269
M30
60
15
flush
2000
100
IIS267
M30
60
30
non-flush
2000
100
IIS268
Dimensions
Example IFS290
Operating voltage
M12 x1
M12 x1
4
17
LED 4 x 90
[V DC]
Short-circuit protection
Overload protection
Example IFS285
60
49
45
IP 65 / IP 66 / IP 67 /
IP 68 / IP 69K
Protection rating
III
Ambient temperature
M12 x1
M12 x1
Protection class
[C]
Housing materials
17
Example IGS280
45
34
30
15
10
Type
yellow (4 x 90)
Version
Order
number
24
Example IFS277
M12 x1
M18 x1
60
49
45
4
LED 4 x 90
24
Example IIS269
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
M12 x1
M30 x1,5
60
49
45
LED 4 x 90
36
60
49
45
22,5
M30x1,5
Example IIS268
M12x1
LED 4 x 90
[LED]
Connection technology
M18x1
M12x1
4
LED 4 x 90
-40...85
brass
plated with white bronze,
sensing face
LCP
4
LED 4 x 90
10...30
36
Position sensors
Position sensors
Inductive sensors
Type
Total length
Sensing range
[mm]
[mm]
Installation
Switching
frequency
[Hz]
Current
load
[mA]
Order
number
2000
100
IFW204
65
flush
M18
65
flush
2000
100
IGW202
M30
65
15
flush
2000
100
IIW202
Dimensions
65
54
50
Operating voltage
M12x1
M12x1
Current consumption
17
IGW202
65
54
50
[mA]
< 20
Short-circuit protection
Overload protection
IP 65 / IP 66 / IP 67 /
IP 68 / IP 69K
Protection
Protection class
II
M12x1
M18x1
Ambient temperature
[C]
24
65
54
50
[LED]
yellow (4 x 90)
Accessories
Type
Version
M30x1,5
M12x1
LED 4 x 90
36
Connection technology
Type
-40...85
brass
anti-spatter,
sensing face LCP
Housing materials
LED 4 x 90
10...30
LED 4 x 90
[V DC]
Version
Order
number
Order
number
E12452
E12453
E12454
M12 washers,
anti-spatter
E12412
Socket, M12,
2 m grey, PUR cable
EVW001
M18 washers,
anti-spatter
E12413
Socket, M12,
5 m grey, PUR cable
EVW002
M30 washers,
anti-spatter
E12414
Socket, M12,
10 m grey, PUR cable
EVW003
Socket, M12,
2 m grey, PUR cable
EVW004
Socket, M12,
5 m grey, PUR cable
EVW005
Socket, M12,
10 m grey, PUR cable
EVW006
Position sensors
10
Position sensors
Capacitive sensors
Type
Evaluation principle
Connection
Housing material
Protection
Current rating
Order
no.
[mA]
Output function NO DC PNP
M22
dynamic
PA
200
KT5102
M22
static
PA
200
KT5106
static
2 m PUR cable
PA
200
KT5110
M22
dynamic
2 m PUR cable
PA
200
KT5111
M22
dynamic
PA
200
KT5112
M22
latching
2 m PUR cable
PA
200
KT5150
M22
latching
PA
200
KT5151
M22
dynamic
2 m PUR cable
Stainless steel
200
KT5309
M22
static
2 m PUR cable
Stainless steel
200
KT5310
M22
latching
2 m PUR cable
Stainless steel
200
KT5350
M22
latching
Stainless steel
200
KT5351
Mounting options
The sensor can be installed in all housings with
a 22.5 mm hole. The supplied lock nut is used
for fixing.
Thanks to the M22 thread the sensor can be used
for screw mounting without lock nut. Installation
alignment of the sensor is not necessary since the clip
showing the symbol for the sensing face is snapped
in as the last step.
Wiring is done via the tried-and-tested 3- or 4-wire
technology.
Description
24 (12...30)
Current consumption
[mA]
30
Ambient temperature
[C]
-40...85
Accessories
Type
Connection technology
Type
[V DC]
Order
no.
Description
Order
no.
Symbol disc,
lettering: START
E12377
Symbol disc,
lettering: STOP
E12378
Symbol disc,
symbol: on
E12379
Socket, M12,
2 m black, PUR cable
EVC001
Symbol disc,
symbol: off
E12380
Socket, M12,
5 m black, PUR cable
EVC002
Symbol disc,
transparent
E12386
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Type
Description
Order
no.
Power supplies
Plastic housing,
24 V DC, 2.5 A
DN1031
11
Position sensors
New pressure-resistant
position sensors
Sensors for pressure up to
500 bar for steel detection
Metal sensing face for heavy duty
High burst pressure of 2,000 bar for the
M12 housing
Standard M12 and M14 housing types
Best performance at an attractive price
Resistant:
withstands 10 million pressure cycles
Operating principle
The new operating principle is based on a magneticinductive technology that detects only ferromagnetic
metals (e.g. tool steel). The sensor is flush-mountable.
Even in case of overflush installation the sensor detects
the steel target and shows reliable switching behaviour
with a sensing range of 1.8 mm. A sealing ring and
a supporting ring are used for sealing against the
pressure zone.
Application examples
Besides use as a limit switch in hydraulic cylinders, the
sensor can also be used on other hydraulic components
such as valves or pumps. Furthermore, it is used in
mechanical engineering processes, e.g. in plastic injectionmoulding or process industry applications. The new
MFH and M9H series sensors offer an impressive performance at an attractive price.
12
Position sensors
Magnetic sensors
Type
Total length
Sensing
range
[mm]
[mm]
Output
Order
no.
[Hz]
Ambient
temperature
[C]
1.8 f
1000
-25...120
MFH200
93
M12
93
1.8 f
1000
-25...120
MFH201
M12
60
1.8 f
1000
-25...120
MFH202
M12
60
1.8 f
1000
-25...120
MFH203
M12
60
1.8 f
1000
-25...120
MFH204
M14
53
1.8 f
1000
-25...85
M9H200
Dimensions
Example MFH202
60
27,8
7,8
M12 x1
M12 x1
[V]
10...36 DC
[mA]
200
Short-circuit protection,
pulsed
Reverse polarity /
overload protection
Protection rating,
protection class
IP 65 / IP 68 / IP 69K,
III
Housing material
stainless steel
316L / 1.4404
Connection
M12 connector
Type
Description
9,7
Operating voltage
Current rating
Connection technology
15
10
Order
no.
17
Wiring diagram
1
L+
L+
Description
EVC001
Socket, M12,
5 m black, PUR cable, LED
EVC008
E12339
E12340
Power supplies
Type
Socket, M12,
2 m black, PUR cable
Order
no.
Plastic housing,
24 V DC, 2.5 A
DN1031
Metal housing,
24 V DC, 3.3 A
DN4011
13
Position sensors
14
Position sensors
Infrared sensors / red light sensors
Range
Spot
diameter
[mm]
[mm]
Connection
M8 connector
Type of light,
wave length
[nm]
Current
consumption
[mA]
8*
4-pole
22
15*
4-pole
16
150**
4-pole
12
4-pole
11
Order
no.
Order
no.
NPN
PNP
O6H401
O6H400
NPN
PNP
O6T401
O6T400
NPN
PNP
O6P401
O6P400
300*
O6S400
4-pole
NPN
PNP
O6E401
O6E400
Accessories
Type
Description
Order
no.
[V DC]
Protection rating,
protection class
Mounting accessories
Mounting set for clamp mounting,
stainless steel, 10 mm
E21272
E21275
Operating voltage
E21271
10...30
IP 65, IP 67, IP 68, IP 69 K,
III
Switching frequency
[Hz]
1000
LED
Yellow
Operation
LED
Green
Current rating
[mA]
100
[V]
< 2.5
Voltage drop
Short-circuit protection, pulsed
E21273
Ambient temperature
[C]
Materials
Housing
Lens
Seal
E21081
E20938
-25...60
High-grade stainless steel
(316L/1.4404), PPSU
PMMA
FKM
Connection technology
Type
Description
Prismatic reflectors
50 mm, plastic
E20956
80 mm, plastic
E20005
E20744
95 x 95 mm, plastic
E20454
Power supplies
Plastic housing,
24 V DC, 2.5 A
DN1031
Metal housing,
24 V DC, 3.3 A
DN4011
Order
no.
EVC153
EVC154
EVC150
EVC151
15
Position sensors
16
Position sensors
Infrared sensors / red light sensors
Range
[mm]
[mm]
Connection
15*
M8 connector,
4-pole
/
adjustable
M8 connector,
4-pole
Order
no.
Order
no.
NPN
PNP
O6T216
O6T215
300*
O6S215
/
adjustable
M8 connector,
4-pole
NPN
PNP
O6E216
O6E215
* at maximum range
Accessories
Type
Description
Order
no.
Type of light
Operating voltage
Protection rating,
protection class
Mounting accessories
Mounting set for clamp mounting,
stainless steel, 10 mm
Mounting set for clamp mounting,
stainless steel, 12 mm
Angle bracket for free-standing
mounting, stainless steel
[V DC]
E21272
E21275
E21271
Switching frequency
[Hz]
1000
LED
Yellow
LED
Green
[mA]
Voltage drop
[V]
E21273
/
[C]
Materials
E21081
E20938
E20950
E20951
Plastic housing,
24 V DC, 2.5 A
Metal housing,
24 V DC, 3.3 A
DN1031
DN4011
Housing
Lens
-25...60
ABS
PMMA
Connection technology
Type
Power supplies
100
< 2.5
10...30
IP 65 / IP 67,
III
Description
Order
no.
EVC153
EVC154
EVC150
EVC151
17
Position sensors
Best performance
The diffuse reflection sensors distinguish themselves by
reliable background suppression, even in case of highly
reflective backgrounds.
A special feature is the automatic switch point adjustment
that guarantees reliable operation even in steam, smoke
or highly reflective environments.
The WetLine series features a particularly robust stainless steel housing with protection rating IP 68 / IP 69K.
The potentiometer with double sealing ensures maximum
ingress resistance. The flush front lens ensures cleaning
without residues.
IO-Link
The O6 WetLine sensors are now also available as versions
with IO-Link. Via this interface, the user can set range,
sensitivity, light-on / dark-on mode, switching delay or
deactivation of the operating elements.
18
Position sensors
Infrared sensors / red light sensors
Range
[mm]
[mm]
Connection
M8 connector
Communication
interface
Current
consumption
[mA]
Order
no.
4-pole
IO-Link 1.1
22
O6H309
4-pole
IO-Link 1.1
16
O6T309
4-pole
IO-Link 1.1
12
O6P309
4-pole
IO-Link 1.1
11
O6S305
4-pole
IO-Link 1.1
O6E309
8*
15*
150**
300*
* at maximum range
** referred to prismatic reflector 80 mm
Accessories
Type
Order
no.
Type of light
Operating voltage
Mounting set for clamp mounting,
stainless steel, 10 mm
E21272
E21271
[V DC]
Protection rating,
protection class
Switching frequency
[Hz]
1000
LED
yellow
Operation
LED
green
adjustable
Current rating
Rod, 120 mm, 10 mm,
M8 thread, stainless steel
10...30
IP 65, IP 67, IP 68, IP 69K,
III
Voltage drop
E21081
[mA]
100
[V]
< 2.5
Ambient temperature
18 x 18 mm, Solidchem plastic
E21267
E21268
E21269
E21270
E30398
LINERECORDER SENSOR,
software for parameter setting and
set-up of IO-Link sensors
E30396
QA0001
[C]
Materials
housing
lens
-25...80
high-grade stainless steel
(316L/1.4404), PPSU
PMMA
Connection technology
Type
Description
Order
no.
M8 socket, 4-pole,
2 m orange, PVC cable
EVT134
M8 socket, 4-pole,
5 m orange, PVC cable
EVT135
M8 socket, 4-pole,
2 m orange, PVC cable
EVT138
M8 socket, 4-pole,
5 m orange, PVC cable
EVT139
Adapter cable
M12 plug to M8 socket 4-pole,
0.3 m orange, PVC cable
EVT248
19
Position sensors
20
Position sensors
Laser sensors / distance measurement sensors
Measuring
range
[mm]
Background
suppression
[m]
Switching
frequency
[Hz]
Hysteresis
[%]
Spot at
max. range
[mm]
Current
consumption
[mA]
Unit of
measurement
Order
no.
PNP
30...2000
...20
11
< 7.5*
<5
< 75
cm
O5D150
30...2000
...20
11
< 7.5*
<5
< 75
inch
O5D151
Accessories
Type
Order
no.
E21083
Type of light
Extraneous light on the object
Dimensions
E21084
max. 8
[mm]
56 x 18,2 x 46,5
[V DC]
10...30
LED
yellow
Operation
LED
Operating voltage
Protective bracket for rod,
complete set incl. clamp
[klx]
Distance value
Rod, 100 mm, 12 mm,
M10 thread, stainless steel
E20938
OUT1: NO
OUT2: NC
Output function
Current rating
E20951
[mA]
Protection rating,
protection class
Short-circuit protection, pulsed
E21087
Dovetail clamp
Ambient temperature
Material
E21088
2 x 100
IP 65,IP 67
III
green
3-digit
alphanumeric
display
[C]
-25...60
PA
PMMA
stainless steel
TPU
Connection technology
Memory plug,
parameter memory for IO-Link sensors
IO-Link interface,
current consumption from USB port
LINERECORDER SENSOR,
software for parameter setting
and set-up of IO-Link sensors
Type
Description
E30398
E30396
QA0001
Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Power supplies
Type
Description
Metal housing,
24 V DC, 3.3 A
Order
no.
DN4011
21
Position sensors
PMDLine M30:
Now also with laser class 1
Photoelectric sensor with time
of flight measurement (PMD),
easy-turn concept, laser class 1
Reliable background suppression and
colour-independent detection
Simple switch point setting by rotatable
setting ring (lock function)
Shiny surfaces are detected reliably
(e.g. stainless steel)
Any sensor position, even an oblique
angle to the object
Laser class 1 for more universal
application
22
Position sensors
Laser sensors / distance measurement sensors
Measuring
range
[mm]
Background
suppression
[m]
Switching
frequency
[Hz]
Hysteresis
[%]
Spot at
max. range
[mm]
Current
consumption
[mA]
Unit of
measurement
Order
no.
PNP
30...2000
...20
11
< 5*
<5
< 75
cm / inch
OID250
30...2000
...20
11
< 5*
<5
< 75
cm
OID251
Accessories
Type
Order
no.
E10737
Type of light
Extraneous light on the object
[klx]
Dimensions
M30 x 90 mm
Operating voltage
Mounting clamp,
with end stop for types M30, PC
E11049
[V DC]
10...30
LED
yellow
Operation
LED
green
E10077
Output function
Current rating
[mA]
Protection rating,
protection class
E20875
E20873
E20874
E20938
Memory plug,
parameter memory for IO-Link sensors
IO-Link interface,
current consumption from USB port
Ambient temperature
[C]
Material
housing
front pane
-25...60
stainless steel,
PBT, PC, FPM
PMMA
Connection technology
Type
2 x 100
IP 65,IP 67
III
max. 8
Description
Order
no.
E20951
E30398
E30396
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Power supplies
Type
LINERECORDER SENSOR,
software for parameter setting
and set-up of IO-Link sensors
Description
Order
no.
QA0001
Metal housing,
24 V DC, 3.3 A
DN4011
23
Position sensors
24
Position sensors
Laser sensors / distance measurement sensors
Measuring
range
[mm]
Background
suppression
[m]
Switching
frequency
[Hz]
Hysteresis
[%]
Spot at
max. range
[mm]
Current
consumption
[mA]
Laser
protection
class
Order
no.
PNP
30...2000
...20
11
< 1.5...3*
<5
< 75
OID204
30...2000
...20
11
< 2.5...5*
<5
< 75
OID254
* at max. range
Accessories
Type
Order
no.
Type of light
Angle bracket for type M30,
stainless steel
E10737
Extraneous light on the object
[klx]
Dimensions
Mounting clamp, with end stop
for types M30, PC
E11049
M30 x 70 mm
Operating voltage
Switching status indication
[V DC]
10...30
LED
Yellow
Switch point
(set)
Mounting clamp for types M30, PTB
E10077
Output function
Current rating
E20951
Max. 8
[mA]
Protection rating,
protection class
2 x 100
IP 65, IP 67, IP 68, IP 69K
III
E30398
IO-Link interface,
current consumption from USB port
E30396
Ambient temperature
Material
/
[C]
Housing
Front pane
-25...60
Stainless steel
PMMA
Hysteresis
y
200
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
175
QA0001
150
125
100
Connection technology
1a
75
Type
Description
Order
no.
50
2a
1b
25
2b
EVC073
EVC074
EVT013
500
1000
1500
2000
25
No compromises
The magnetic sensing principle provides the accuracy of
photoelectric encoders and the robustness of magnetic
systems.
Simple
Resolution and signal level can be programmed. The
encoders have a wide voltage range of 4.5...30 V DC
and are therefore suited for universal use.
Multifunctional
Performance Line encoders have an integrated signal
evaluation for speed monitoring, counter functions
and detection of the direction of rotation.
Intuitive
The encoders provide easy setting, position indication
by means of display and operating keys and intuitive
menu navigation.
Networked
Diagnostic and parameter data are reliably transferred
via IO-Link. Ready for Industry 4.0.
26
Housing
Shaft
[mm]
[mm]
Flange
Resolution
Operating voltage
[pulse/revolution]
[V DC]
IO-Link
Order
no.
ROP520
Hollow shaft with integrated stator coupling 4-digit display Integrated pulse evaluation
58
12
direct
4.5...30
servo
4.5...30
RUP500
58
10
clamp flange
4.5...30
RVP510
Accessories
Type
Order
no.
Switching frequency
[kHz]
Protection
Spring disc coupling,
6 mm / 10 mm, die-cast zinc; PA
E60117
E60118
E60041
E60066
E60067
E60022
E60028
Measuring wheel,
159.15 mm / 10 mm, Hytrel TPE-E
E60110
Measuring wheel,
159.16 mm / 10 mm, aluminium, PU
E60076
Measuring wheel,
63.66 0.1 mm / 10 mm, Hytrel TPE-E
E60138
Measuring wheel,
63.6 mm, 10 mm, aluminium
E60095
Measuring wheel,
63.66 0.1 mm / 6 mm, aluminium
E60137
Measuring wheel,
63.6 mm, 6 mm, aluminium
E60006
E60033
E60035
300
IP 65, IP 67
M12 connector
(rotatable)
Connection
Accessories
Type
Description
Order
no.
E30390
E12432
LINERECORDER SENSOR,
Software for parameter setting and
set-up of IO-Link sensors
QA0001
E30398
Connection technology
Type
Description
Order
no.
E12402
E12403
E12404
27
Programmable incremental
encoder with IO-Link
Reduce stock without
compromise
Flexible: Resolution of 2...10,000 freely
programmable
Simple: Signal level can be set in TTL
or HTL logic
Universal: M12 connector or radial or
axial cable entry
Standard fitting: Solid shaft (clamp /
synchro flange) or hollow shaft design
Communicative: Transfer of process
and diagnostic data via IO-Link
No compromises
The magnetic sensing principle provides the accuracy of
photoelectric encoders and the robustness of magnetic
systems.
Select the right encoder in just 2 minutes
The days of confusing type variety and encoders with
complicated programming are finally over! The new
incremental encoders from ifm electronic can be used
universally due to the intelligent product and function
design, and stand out thanks to a superb price /
performance ratio:
Set the resolution individually
Choose between TTL or HTL logic
Use the rotatable M12 connector or the cable entry
radially or axially
Now select a flange and shaft thats it!
IO-Link communication
Process values, parameter setting and diagnostic data
can now be transmitted via IO-Link. So, settings can be
simply made prior to installation.
28
Housing
Shaft
[mm]
[mm]
Flange
Resolution
Connection
IO-Link
Order
no.
RA3100
[pulse/revolution]
direct
M12
36.5
direct
cable, 2 m
RA3500
58
12
direct
M12
RO3100
58
12
direct
cable, 2 m
RO3500
36.5
Solid shaft
36.5
universal
M12
RB3100
36.5
universal
cable, 2 m
RB3500
58
servo
M12
RU3100
58
servo
cable, 2 m
RU3500
58
10
clamp flange
M12
RV3100
58
10
clamp flange
cable, 2 m
RV3500
Accessories
Type
Order
no.
Operating voltage
[V DC]
Switching frequency
Spring disc coupling,
6 mm / 10 mm, die-cast zinc; PA
E60117
E60118
E60041
E60066
E60067
E60022
E60028
Measuring wheel,
159.15 mm / 10 mm, Hytrel TPE-E
E60110
Measuring wheel,
159.16 mm / 10 mm, aluminium, PU
E60076
Measuring wheel,
63.66 0.1 mm / 10 mm, Hytrel TPE-E
E60138
Measuring wheel,
63.6 mm, 10 mm, aluminium
E60095
Measuring wheel,
63.66 0.1 mm / 6 mm, aluminium
E60137
Measuring wheel,
63.6 mm, 6 mm, aluminium
E60006
E60033
E60035
[kHz]
Protection
300
IP 65, IP 67
Accessories
Type
4.5...30
Description
Order
no.
E30390
LINERECORDER SENSOR,
software for parameter setting and
set-up of IO-Link sensors
QA0001
E30398
Connection technology
Type
Description
Order
no.
EVC544
EVC545
EVC546
29
Precision counts
The 2-axis inclination sensors are designed for high
measurement accuracies over the whole angular range.
All functions can be configured via IO-Link.
Thanks to an active temperature compensation and high
protection rating they operate reliably even at extreme
ambient temperatures and rough environments.
Vibration monitoring
Alternatively, JN2200 can also be used for 3-axis vibration monitoring. Up to 3 axes can be included into the
calculation of the characteristic value.
Typical applications are the detection of structural
vibration or tower vibration to ISO 4866, or machine
monitoring to ISO 10816.
30
Dimensions
The products
Type
Description
Order
no.
62
45
22
90
75
JN2200
JN2201
5,3
36
4,5
Technical data
JN2200, JN2201
Operating voltage
with:
Switching and current outputs
Voltage output
IO-Link connection
Connection technology
Type
Description
9.2...30
12...30
18...30
Socket, M12,
2 m black, PUR cable
EVM039
Socket, M12,
10 m black, PUR cable
EVM041
Socket, M12,
2 m black, PUR cable
EVM036
Socket, M12,
10 m black, PUR cable
EVM038
Jumper, M12,
5 m black, PUR cable
EVC069
Jumper, M12,
5 m black, PUR cable
[V DC]
JN2200
180/ 90
0.5
0.1
0.05
JN2201
45
0.1
0.05
0.01
0.1...400
0.5...50
Angular range
Absolute accuracy
Repeatability
Resolution
Frequency range
Measuring range
[Hz]
[g] 2, 4, 8
Ambient temperature
[C]
Temperature coefficient
[/K]
-40...85
0.002
Protection rating
IP 65 / IP 67 / IP 68 /
IP 69K
Housing material
diecast zinc
nickel-plated
EVC059
2x
M12 connector
(4 poles; A-coded)
Connection
IO-Link 1.1,
COM 2,
38.4 kbaud
Communication interface
Accessories
Type
Description
Order
no.
LINERECORDER SENSOR
Software for parameter setting and
set-up of IO-Link sensors
QA0001
E30390
E30398
31
32
The products
Type
Description
Order
no.
JN2100
JN2101
JN2300
JN2301
Technical data
JN2100, JN2101,JN2300, JN2301
Operating voltage
[V DC]
9.2...30
Dimensions
Angular range
Resolution
Repeatability
90
75
60
45
22
Ambient temperature
[C]
-40...85
Temperature coefficient
[/K]
0.002
IP 65 / IP 67 / IP 68 /
IP 69K
36
4,5
Protection
CANopen
Device profile
CiA DSP-410 /
SAE J1939
Data interface
Connection technology
Description
JN2101
JN2301
45
0.01
0.05
5,3
Type
JN2100
JN2300
180
0.05
0.1
Order
no.
Socket, M12,
2 m black, PUR cable
EVM039
Socket, M12,
10 m black, PUR cable
EVM041
Socket, M12,
2 m black, PUR cable
EVM036
Socket, M12,
10 m black, PUR cable
EVM038
Jumper, M12,
5 m, black, PUR cable
EVC069
Jumper, M12,
5 m, black, PUR cable
EVC059
[Hz]
Filter for
vibration monitoring
[Hz]
adjustable:
10, 5, 1, 0.5
0.1...1, 0.1...10, 1...10,
2...400, 10...400
Diecast zinc
nickel-plated
Housing material
2x
M12 connector
Connection
Accessories
Type
Description
Order
no.
EC2062
33
Application
The evaluation units control levels in tanks by means
of sensors thus protecting against overflow, running
dry and leakage, for example.
Level control with a sensor
The DL0201 evaluation unit uses a sensor that is
installed at the tank at the height of the limit level to
be monitored. When the level has been reached, the
evaluation unit switches for an adjustable period of
time to stop pumps, for example, as overflow or run-dry
protection.
Level control with two sensors
The DL0203 evaluation unit is a typical 2-point control
that controls an upper and a lower limit on pumps and
valves by means of two sensors.
34
Type
Nominal voltage
Inputs
Signal / enable
[V]
Input
frequency
[Hz]
Auxiliary energy
for sensors
Outputs
Relays / transistors
Order
no.
1 x PNP / 1 x PNP
(type 2
acc. to IEC 61131-2)
typ. 18.5...30 V DC /
100 mA
short circuit /
overload protected
1/1
DL0201
2 x PNP /
(type 2
acc. to IEC 61131-2)
typ. 18.5...30 V DC /
100 mA
short circuit /
overload protected
1/1
DL0203
Relay outputs
1 x PNP /
externally supplied
10...30 V DC SELV /
100 mA
Transistor outputs
Ambient temperature
[C]
-25...60
Storage temperature
[C]
-25...70
Protection
housing / terminals
Display DL0201
IP 20 / IP 20
LED
Power supply
Input
Output
Enable
Display DL0203
Green
Yellow
Green (lights if
relay energised
and transistor
switched)
Green (lights if
enable signal is present)
LED
Power supply
Input
Output
Green
2 x yellow
Green (lights if
relay energised
and transistor
switched)
4-pole connector
with screw connection,
5.0 mm pitch
Connection
Accessories
Type
Description
Order
no.
Connector,
4 poles with screw terminals,
pack of 5
(supplied)
E40173
Connector,
4 poles with cage clamps,
pack of 5
E40171
35
36
Type
Ub
Inputs
Pulse
input
[V]
Input
frequency
[Hz]
Outputs
Relay
Auxiliary energy
for sensors
Order
no.
PNP / NPN
10
24 V DC,
300 mA
DN0210
110...240 AC
50...60 Hz
PNP / NPN
10
24 V DC,
2 x 150 mA
DN0220
Dimensions
LED s
Setting range:
selectable for PNP and NPN switching sensors
Relay output
Contact rating
[A]
35,5
109,1
93
112,6
25,4
[V]
24 DC SELV, 10 %,
300 mA,
short-circuit and
overload protected
Protection
housing / terminals
Ambient temperature
Display DN0210
Power
AC
Power
AC
21 22 23 24
L L N N
21 22 23 24
L L N N
9 Sensor
12 supply
10 pnp/npn
8
7
6
5
IP 20 / IP 20
[C]
1 x green
1 x yellow (lights,
if output relay
is energised)
1 x red
Out
In
1
9 Sensor
12 supply
10 pnp/npn
LED
Power supply
Output
In
2
13 Sensor
16 supply
14 pnp/npn
1 x green
2 x yellow (light,
if output relay
is energised)
1 x red
Fault
Selection
PNP / NPN
Potentiometer
Plastic:
PC GF20
Housing material
8
7
6
5
Out
1
Rail TH35
(according to EN 60715)
Mounting
Unit:
4-pole terminal blocks
with 5.0 mm pitch;
Connector:
4 poles with
screw connection
Connection
20
19
18
17
Out
2
Accessories
Type
DN0210 (1-channel)
-20...60
LED
Power supply
Output
Fault
Display DN0220
Wiring diagram
In
Description
DN0220 (2-channel)
Order
no.
Connector,
4 poles with screw terminals,
pack of 5
(supplied)
E40173
Connector,
4 poles with cage clamps,
pack of 5
E40171
37
Applications
The speed monitor DU110S has been developed for
safety-related minimum-speed monitoring required, for
example, for slip or V-belt monitoring.
An application example is the industrial thermoprocessing equipment according to EN 746-2. In this
case, safety-related monitoring of the air exchange is
required. To do so, monitoring is done via the rotational
speed monitoring of the fans.
Special features
The speed monitor is certified to EN 62061 / SIL 3 and
EN ISO 13849-1 cat. 4 / PL e even though non-safetyrelated sensors are used as pulse pick-ups.
When the safety output has been triggered, it can be
reset again manually or automatically.
38
Technical data
Safety speed monitor
DU110S
Evaluation system for safe speed monitoring
Operating voltage
[V DC]
Nominal voltage
[V DC]
Current consumption
19.2...28.8;
incl. 5 %
residual ripple
24
[mA]
125
Sensor supply
24 V DC / 70 mA
Protection
IP 20 / II
Pulse inputs
S34, S43:
1: 6 mA / 24 V DC
Input characteristics
Adjustable speed range
[rpm]
[Hz]
Input frequency
[Hz]
10...49500
0.1...990
5000
2 safety-related switching
outputs (floating contacts)
1 fault output Fault
(positive switching)
1 diagnostic output
Overspeed
(positive switching)
Output function
Dimensions
22,5
Output characteristics
6 A,
250 V AC / 24 V DC
( 6 mA);
resistive load
35,5
99
108
LED
114,5
Contact rating
Ambient temperature
[C]
-40...55
Storage temperature
[C]
-40...75
[%]
95,
non condensing
PA
(polyamide)
Housing materials
1) Screw terminals
2) Rotary switch
3) DIN rail mounting
Rail TH35
(according to EN 60715)
Mounting
Wiring diagram
Screw terminals;
0.5...2.5 mm
(AWG 12...30)
Connection
VCC = 24 V DC
Sensor 1
Sensor 2
Accessories
Type
L- L+ S33 S34 S35
(GND)
13
23
14
24
Description
Order
no.
Power supplies
24 V DC
Enable 1
Y3 Y4 Y2
Y1
Y5
Y6
Y7
Y8
K1
K1
Restart
K2
Plastic housing,
24 V DC, 2.5 A
DN1031
Metal housing,
24 V DC, 3.3 A
DN4011
K2
24 V
Fault
Overspeed
Enable 2
39
Industrial imaging
40
Industrial imaging
Camera systems for
mobile machines
Type of sensor
Resolution
pixels
[pixel]
Angle of aperture
horizontal x vertical
[]
Illumination
Max.
sampling rate
[Hz]
Order
no.
25/33/50
O3M151
64 x 16
ext. illumination
required
70 x 23
diecast aluminium
Device connection
M12 connector
Protection rating,
protection class
IP 67 / IP 69K,
III
Operating voltage
[V DC]
9...32
[mA]
< 400
[A]
Ambient temperature
<5
[C]
-40...85
1x CAN,
1 x fast Ethernet
Interfaces
CANopen,
SAE J 1939
CE,
E1 (UN-ECE R10)
Accessories
Description
Order
no.
O3M950
EC2112
EC2114
E3D300
U-shaped holder,
suitable for sensor or illumination unit
E3M100
E3M103
Connection technology
Type
Description
Order
no.
E3M121
E3M122
E3M131
E3M133
E11898
E12204
41
Industrial imaging
42
Industrial imaging
Camera systems for
mobile machines
Type of sensor
Resolution
pixels
[pixel]
Angle of aperture
horizontal x vertical
[]
Illumination
Max.
sampling rate
[Hz]
Order
no.
25/33/50
O3M150
64 x 16
ext. illumination
required
70 x 23
diecast aluminium
Device connection
M12 connector
Protection rating,
protection class
IP 67 / IP 69K,
III
Operating voltage
[V DC]
9...32
[mA]
< 400
[A]
Ambient temperature
<5
[C]
-40...85
1x CAN,
1 x fast Ethernet
Interfaces
CANopen,
SAE J 1939
CE,
E1 (UN-ECE R10)
Accessories
Description
Order
no.
O3M950
EC2112
EC2114
E3D300
U-shaped bracket,
suitable for sensor or illumination unit
E3M100
E3M103
Connection technology
Type
Description
Order
no.
E3M121
E3M122
E3M131
E3M133
E11898
E12204
43
Industrial imaging
44
Industrial imaging
3D sensors
Type of sensor
Material
housing
Material
front pane /
LED window
Max.
field of view size
[m]
Order
no.
Aluminium
Gorilla glass /
polyamide
IP 65 / IP 67,
III
40 x 30
2.61 x 3.47
O3D300
Aluminium
Gorilla glass /
polyamide
IP 65 / IP 67,
III
60 x 45
3.75 x 5.00
O3D302
Stainless steel
Polycarbonate /
polyamide
IP 66 / IP 67,
III
40 x 30
2.61 x 3.47
O3D310
Stainless steel
Polycarbonate /
polyamide
IP 66 / IP 67,
III
60 x 45
3.75 x 5.00
O3D312
Technical data
Completeness monitoring
Operating distance
[m]
0.3...5
[mm]
25
45
Sampling rate /
[Hz]
switching frequency
The image repetition frequency is
reduced by using the position tracking
function
10
Description
Current consumption
[mA]
Current rating
(per switching output)
[mA]
Order
no.
E3D301
Type
Description
Ethernet jumper,
2 m, PVC cable, M12 / M12
Socket, M12,
2 m black, PUR cable, 8 poles
[C]
176 x 132
pixels
LED
2 x yellow,
2 x green
850 nm,
infrared
Illumination
[lux]
Max. 10,000
(indoor)
Trigger
External;
24 V PNP/NPN
according to
IEC 61131-2 type 3
Switching inputs
2
(configurable),
24 V PNP/NPN
according to
IEC 61131-2 type 3
Order
no.
E11898
3
(configurable),
24 V PNP/NPN,
according to
IEC 61131-2
Switching outputs
E21138
E11950
-10...50
25,000 /
100,000
Ambient light
Connection technology
100
Function display
Mounting set for O3D
20.4...28.8
< 2400 peak current
pulsed;
typ. mean value
420
Overload protection
Ambient temperature
Accessories
Type
[V DC]
64 objects
Via PC /
notebook
Dimensions (H, W, D)
[mm]
72 x 65 x 85
45
Industrial imaging
46
Industrial imaging
3D sensors
Type of sensor
Material
housing
Material
front pane /
LED window
Max.
field of view size
[m]
Order
no.
Aluminium
Gorilla glass /
polyamide
IP 65 / IP 67,
III
40 x 30
2.61 x 3.47
O3D300
Aluminium
Gorilla glass /
polyamide
IP 65 / IP 67,
III
60 x 45
3.75 x 5.00
O3D302
Stainless steel
Polycarbonate /
polyamide
IP 66 / IP 67,
III
40 x 30
2.61 x 3.47
O3D310
Stainless steel
Polycarbonate /
polyamide
IP 66 / IP 67,
III
60 x 45
3.75 x 5.00
O3D312
Technical data
Dimensioning of the object
Operating distance
[m]
0.3...5
Object type
Min. object size
[mm]
Object speed
[m/s]
< 0.2
Typical accuracy
for object size
[mm]
Typical accuracy
for object position
[mm]
Typical accuracy
for angle of rotation
[]
10
5
Description
Current consumption
[mA]
Current rating
(per switching output)
[mA]
Order
no.
E3D301
[C]
Description
Order
no.
176 x 132
pixels
Function display
LED
Ambient light
[lux]
Socket, M12,
2 m black, PUR cable, 8 poles
E11950
Max. 10,000
(indoor)
Trigger
External;
24 V PNP/NPN
according to
IEC 61131-2 type 3
Switching inputs
2
(configurable),
24 V PNP/NPN
according to
IEC 61131-2 type 3
3
(configurable),
24 V PNP/NPN,
according to
IEC 61131-2
E11898
E21138
2 x yellow,
2 x green
850 nm,
infrared
Switching outputs
Ethernet jumper,
2 m, PVC cable, M12 / M12
-10...50
25,000 /
100,000
Connection technology
Type
100
Illumination
Mounting set for O3D
20.4...28.8
< 2400 peak current
pulsed;
typ. mean value
420
Overload protection
Ambient temperature
Accessories
Type
[V DC]
Rectangular
Via PC /
notebook
Dimensions (H, W, D)
[mm]
72 x 65 x 85
47
Industrial imaging
48
Industrial imaging
3D cameras
Type of sensor
Material
housing
Material
front pane /
LED window
Protection rating,
protection class
Angle of
aperture
[]
Max.
field of view size
[mm]
Order
no.
Aluminium
Gorilla glass /
polyamide
IP65 / IP67,
III
40 x 30
2.61 x 3.47
O3D301
Infineon 3D
Image Sensor
Aluminium
Gorilla glass /
polyamide
IP65 / IP67,
III
60 x 45
3.75 x 5.00
O3D303
3D
Image Sensor
Stainless steel
Polycarbonate /
polyamide
IP66 / IP67,
III
40 x 30
2.61 x 3.47
O3D311
Infineon 3D
Image Sensor
Stainless steel
Polycarbonate /
polyamide
IP66 / IP67,
III
60 x 45
3.75 x 5.00
O3D313
Infineon
Accessories
Type
Order
no.
E3D301
Connection technology
Type
Description
Order
no.
E11898
Operating voltage
[mA]
Current rating
(per switching output)
[mA]
E21138
EVC070
socket, M12,
5 m black, PUR cable, 5 poles
EVC071
100
Short-circuit protection
Ambient temperature
[C]
-10...50
Range
[m]
Typically 5
Unambiguous range
[m]
0...30
Sampling rate /
switching frequency
[Hz]
Max. 20,
adjustable
176 x 132
pixels
Resolution
LED
2 x yellow,
2 x green
850 nm,
infrared
Illumination
Ambient light
Socket, M12,
2 m black, PUR cable, 5 poles
24
< 1000 (max. 2500)
Overload protection
Function display
Ethernet jumper,
2 m, PVC cable, M12 / M12
[V DC]
Current consumption
[lux]
Max. 10,000
(indoor)
Trigger
Internal or external:
24 V PNP / NPN selectable,
according to
IEC 61131-2 type 2
Switching inputs
Max: 2 (configurable),
24 V PNP / NPN selectable,
according to
IEC 61131-2 type 2
Switching outputs
Max: 2 (configurable),
24 V PNP / NPN selectable
or 1 analogue output (configurable) scalable, 4...20
mA according to
IEC 61131-2,
max. load 300 ,
0...10 V according to
IEC 61131-2,
min. load 10 k
Via PC /
notebook
49
Process sensors
50
Process sensors
Pressure sensors
Measuring range
relative pressure
[bar]
Poverload
max.
[bar]
Pburst
min.
[bar]
Order
no.
25
Measuring range
relative pressure
[bar]
Poverload
max.
[bar]
Pburst
min.
[bar]
Order
no.
300
PT5704
0...10
25
300
PU5704
0...25
65
600
PT5703
0...25
65
600
PU5703
0...100
250
1000
PT5702
0...100
250
1000
PU5702
0...250
625
1200
PT5701
0...250
625
1200
PU5701
0...400
1000
1700
PT5700
0...400
1000
1700
PU5700
0...600
1500
2400
PT5760
0...600
1500
2400
PU5760
0...10
25
300
PT5604
0...10
25
300
PU5604
0...25
65
600
PT5603
0...25
65
600
PU5603
0...100
250
1000
PT5602
0...100
250
1000
PU5602
0...250
625
1200
PT5601
0...250
625
1200
PU5601
0...400
1000
1700
PT5600
0...400
1000
1700
PU5600
0...600
1500
2400
PT5660
0...600
1500
2400
PU5660
Dimensions
21,8
Operating voltage
12
19
G1 4
Type PT56/PU56
21,8
14,35
72
51,9
25,8
12
19
19
1
8...32
16...32
51,4
71,5
19
PT [V DC]
PU [V DC]
G1 4
Accuracy / deviation
(in % of the span)
Linearity error
Linearity
Hysteresis
Repeatability
Long-term stability
Temperature coefficients (TEMPCO)
in the temperature range 0 ... 80 C
(in % of the span per 10 K)
TEMPCO of zero
TEMPCO of the span
Temperature coefficients (TEMPCO)
in the temperature ranges
-40...0 C and 80...125 C
(in % of the span per 10 K)
TEMPCO of zero
TEMPCO of the span
Medium temperature
< 0.8
< 0.25 BFSL / < 0.5 LS
< 0.2
< 0.05
< 0.1
< 0.1
< 0.1
< 0.2
< 0.2
[C]
-40...125
Protection
Wiring diagram
IP 67 / IP 69K
L+
OUT
Type PT56
1
Type PU57
A
C
B
L+
OUT
L-
OUT
L+
2
3
L-
Restrictor
EMC
Type PU56
1
Accessories
OUT
L+
Type
Description
Order
no.
E30135
51
Process sensors
Application areas
The PS series submersible pressure transmitters are
used for level measurement in containers, tanks, wells,
flowing water, bore holes and wastewater plants. The
accuracy of 0.5 % and the long-term stability of 0.2 %
per year contribute to the reliable operation of the
transmitter.
Robust, reliable and flexible
All submersible pressure transmitters have a robust
high-grade stainless steel housing. For standard applications the favourably priced PUR cable can be used.
For applications where a high resistance to media is
requested (e.g. slurry, oils or fuels) the FEP cable is
available.
The ATEX submersible pressure transmitters of the
PS3xxA series are designed for level measurement in
areas subject to explosion. The sensors can be used in
zone 0, 1, 2 or zone 20, 21, 22 as well as in mining.
The GL approval allows an application in the maritime
sector.
Level measurement in a water treatment plant
52
Process sensors
Pressure sensors
Measuring range
Relative pressure
[bar]
Overload pressure
Cable length
[bar]
Approvals
CE / EX / GL
Order
no.
[m]
1000 N
//
PS3208
0.6
1000 N
10
//
PS3407
0.6
1000 N
15
//
PS3427
0.6
1000 N
30
//
PS3607
1000 N
15
//
PS3417
1000 N
30
//
PS3617
Submersible pressure transmitters with FEP cable for high resistance to media
0.25
500 N
//
PS4208
0.6
500 N
10
//
PS4407
500 N
15
//
PS4417
500 N
//
PS308A
0.6
500 N
10
//
PS307A
500 N
15
//
PS317A
Dimensions
[V DC]
18...30
[mA]
4...20
100
27
Analogue output
Accuracy / deviation
(in % of the span)
Accuracy (BFSL)
Accuracy incl. non-linearity
Non-linearity (BFSL)
Long-term stability per year
Accessories
Type
Description
Filter element *
Splitter box *
with vent and terminal block
Order
no.
E30399
-10...50
Design PS4
Ambient temperature /
Medium temperature
[C]
-10...85
E30400
E30401
0.2
0.2
Design PS3
Ambient temperature /
Medium temperature
Design PS3
ATEX approval
Ambient temperature /
Medium temperature
Housing material
Additional weight, approx. 500 g
[C]
E30402
53
Process sensors
54
Process sensors
Pressure sensors
Measuring cell
Measuring range
relative pressure
Order no.
G 1/4
female
M12 connector
output function programmable
Order no.
G 1/4
male
Order no.
G 1/4
female
Order no.
G 1/4
male
Order no.
G 1/4
female
2 x NO/NC or
1 x NO/NC + 1 x analogue
(4...20 mA / 0...10 V;
scalable)
NO/NC
+ analogue:
4...20 mA / 0...10 V
2 x NO/NC
Order no.
G 1/4
male
0...600 bar
PN7160
PN7560
PN3160
PN3560
PN2160
PN2560
0...400 bar
PN7070
PN7570
PN3070
PN3570
PN2070
PN2570
0...250 bar
PN7071
PN7571
PN3071
PN3571
PN2071
PN2571
0...100 bar
PN7092
PN7592
PN3092
PN3592
PN2092
PN2592
0...25 bar
PN7093
PN7593
PN3093
PN3593
PN2093
PN2593
-1...10 bar
PN7094
PN7594
PN3094
PN3594
PN2094
PN2594
0...2,5 bar
PN7096
PN7596
PN3096
PN3596
PN2096
PN2596
0...1000 mbar
PN7097
PN7597
PN3097
PN3597
PN2097
PN2597
-12,5...250 mbar
PN2098
PN2598
-1000...1000 mbar
PN7099
PN7599
PN2099
PN2599
Metal
(thin film)
Ceramiccapacitive
-1000...0 mbar
PN3129
PN3529
-500...500 mbar
PN2169
PN2569
Accessories
Type
Description
Order
no.
E30421
Operating voltage
[V DC]
Current rating
E30420
[mA]
18...30
200
(up to 60 C environment)
Accuracy / deviation
(in % of the span) turn down 1:1
Deviation of the switch point
Linearity error
Repeatability
Tag clip
E30422
E30419
E30057
[Hz]
170
Medium temperature
[C]
-25...80
Protection
Siphon, G 1/4,
steel (1.0345)
E30140
IP 67
Shock resistance
[g]
Vibration resistance
[g]
50
20
IO-Link 1.1
COM2 slave;
38.4 kbaud
Communication interface
Memory plug,
parameter memory for IO-Link sensors
< 0.2
< 0.2
E30398
Connection technology
IO-Link interface, current consumption
from USB port
LINERECORDER SENSOR,
software for parameter setting
and set-up of IO-Link sensors
Type
Description
E30396
QA0001
Order
no.
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
55
Process sensors
IO-Link display:
process values at a glance
More plant transparency and
service information on site
Four measured values / text displays and
four message windows for free text
Colour change for text and background
Flexible adaptation of the display, also
during operation
IO-Link 1.1 compatible
Easy integration into each IO-Link
structure
56
Process sensors
IO-Link display
Dimensions
Display type
Display
illumination
Order
no.
TFT
LED
E30391
11
39,5
M12x1
Resolution
pixels
101
Technical data
45
34
IO-Link display
E30391
86
Operating voltage
[V DC]
Current consumption
[mA]
Protection rating /
protection class
Wiring
1
BN
BK
BU
L+
OUT
18...30
< 47
IP 65, IP 67 /
III
Communication interface
IO-Link device
Type of transmission
IO-Link revision
SDCI standard
Ambient temperature
[C]
0...60
EN 61000-6-2
EN 61000-6-4
EMC
Shock resistance
[g]
20 (11 ms)
Vibration resistance
[g]
20 (10...50 Hz)
Stainless steel
(303/1.4305);
PC; PBT-GF 30;
PPS; PA 6.6; FKM
Housing materials
Connection
M12 connector
Connection technology
Type
Description
Order
no.
M12 jumper
1 m black, PUR cable
EVC042
M12 jumper
2 m black, PUR cable
EVC043
M12 jumper,
3 m black, PUR cable
EVC102
M12 jumper,
5 m black, PUR cable
EVC044
M12 jumper,
10 m black, PUR cable
EVC493
57
Process sensors
Measurement technique
The SA volumetric flow sensor operates using the
calorimetric measuring principle. Two measuring
elements as well as a heat source are located on the
measuring tip. The physical effect that a flowing
medium absorbs heat energy and conducts it away is
used. The resulting temperature change is an indication
of flow.
Device function
The new SA-type sensor has been designed to detect
and measure flow and temperature even in large internal
pipe diameters up to 400 mm.
Therefore it serves different applications. Switching
outputs, analogue signals and IO-Link provide various
options to further process the signals. That means that
the user is best-equipped for Industry 4.0.
58
Process sensors
Flow sensors / flow meters
Type
Measuring range
liquid / gaseous
[cm/s]
Medium
temperature
[C]
Pressure
resistance
[bar]
Response
time
[s]
Probe length
-20...90
100
0.5
45
Order
no.
[mm]
M18
SA5000
Progressive ring
5...300 / 200...10000
-20...100
50
0.5
100
SA4100
Progressive ring
5...300 / 200...10000
-20...100
50
0.5
200
SA4300
Dimensions
Example SA5000
48
34
40
M12 x1
81
Operating voltage
[V]
18...30 DC
Current consumption
[mA]
< 100
Current rating
[mA]
250
1K
(5 % MW
+ 2 % VMR)
at reference
conditions
15
22
Housing materials
1) LEDs (display unit / switching status)
2) 4-digit alphanumeric display / alternating indication of red and green
3) Programming buttons
4) Upper part of the housing can be rotated by 345
Connection
M12 connector
Accessories
Wiring
Type
1
BN
WH
BK
BU
Description
L+
Order
no.
OUT2
OUT1
L
Connection technology
Type
IP 65 / IP 67, III
High grade stainless steel
(1.4404/316L);
PBT-GF 20;
PBT-GF 30
Description
Order
no.
M12 socket,
2 m black, PUR cable
EVC001
M12 socket,
5 m black, PUR cable
EVC002
M12 socket,
2 m black, PUR cable
EVC004
M12 socket,
5 m black, PUR cable
EVC005
M12 socket,
2 m orange, PVC cable
EVT064
M12 socket,
5 m orange, PVC cable
EVT001
E30390
E40096
E40099
E40258
59
Process sensors
60
Process sensors
Flow sensors / flow meters
Measuring range
Medium
temperature
[C]
[l/min]
Response time
T90
[s]
Nominal
diameter
[]
Max. operating
pressure
[bar]
Process
connection
Order
no.
DN8
12
G 1/2
SV4200
<1
1.0...20
-10...90
<1
DN8
12
Rc 1/2
SV4500
2.0...40
-10...90
<1
DN10
12
G 1/2
SV5200
1.0...20
2.0...40
-10...90
<1
DN10
12
Rc 1/2
SV5500
5.0...100
-10...90
<1
DN20
12
G 3/4
SV7200
5.0...100
-10...90
<1
DN20
12
Rc 3/4
SV7500
SV4204
-10...90
<1
DN8
12
G 1/2
1.0...20
-10...90
<1
DN8
12
Rc 1/2
SV4504
2.0...40
-10...90
<1
DN10
12
G 1/2
SV5204
2.0...40
-10...90
<1
DN10
12
Rc 1/2
SV5504
5.0...100
-10...90
<1
DN20
12
G 3/4
SV7204
5.0...100
-10...90
<1
DN20
12
Rc 3/4
SV7504
Wiring diagram
1
BN
WH
BK
BU
L+
OUT2
OUT1
Operating voltage
[V]
Current consumption
Connection technology
Type
Description
[mA]
(2 % MV
+ 2 % VMR)
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m orange, PVC cable
EVT064
Socket, M12,
5 m orange, PVC cable
EVT001
18...30 DC
typ. 25 (at 24 V)
1K
IP 65 / IP 67, III
Output 1
(for DC PNP / NPN version)
IO-Link,
switching output
or
frequency output flow
Output 2
(for DC PNP / NPN version)
Switching output
flow / temperature
or
frequency output flow /
temperature
Accessories
Type
Description
Order
no.
Mounting plate
E40249
E40250
E40251
E30396
61
Process sensors
62
Process sensors
Flow sensors / flow meters
Type
Process
connection
Measuring range
Response time
Operating voltage
[l/min]
Pressure
resistance
[bar]
[ms]
[V]
0.2...4
80
10
24 DC
Order
no.
Rp 1/2
Dimensions
SBY321
[mA]
< 15
Ambient temperature
[C]
0...60
94...99
13
13
Short-circuit protection
Housing materials
Brass
chemically nickel-plated;
anodised aluminium;
PA
Materials in contact
with the medium
18
66,5
107...113
Wiring
1 BN
L+
Connection
4 BK
3 BU
IP 65 / IP 67, III
Overload protection
Rp
Rp
27
Current consumption
M12 connector
Connection technology
Type
Description
Order
no.
M12 socket,
2 m black, PUR cable
EVC001
M12 socket,
5 m black, PUR cable
EVC002
M12 socket,
2 m black, PUR cable
EVC004
M12 socket,
5 m black, PUR cable
EVC005
M12 socket,
2 m orange, PVC cable
EVT064
M12 socket,
5 m orange, PVC cable
EVT001
63
Process sensors
64
Process sensors
Flow sensors / flow meters
Type
Measuring range
Medium temperature
Response time
Process connection
Order
no.
[ms]
Max.
operating pressure
[bar]
[l/min]
[C]
Rp 3/4
SBY232
SBY233
-10...100
< 10
40
0.5...25
-10...100
< 10
40
Rp 3/4
1.0...50
-10...100
< 10
40
Rp 3/4
SBY234
2.0...100
-10...100
< 10
25
Rp 1
SBY246
4.0...200
-10...100
< 10
25
Rp 1 1/2
SBY257
0.3...15
-10...100
< 10
40
G 1/2
SBG232
0.5...25
-10...100
< 10
40
G 1/2
SBG233
SBG234
1.0...50
-10...100
< 10
40
G 1/2
2.0...100
-10...100
< 10
25
G 3/4
SBG246
4.0...200
-10...100
< 10
25
G 1 1/4
SBG257
Wiring diagram
1
BN
WH
BK
BU
L+
OUT2
OUT1
Operating voltage
[V DC]
Current consumption
Connection technology
Type
Description
[mA]
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Socket, M12,
2 m orange, PVC cable
EVT064
Socket, M12,
5 m orange, PVC cable
EVT001
< 50
(4 % MV
+ 1 % VMR)
18...30
3K
IP 65 / IP 67, III
Output 1
IO-Link,
switching output,
frequency output
flow / temperature
Output 2
Accessories
Type
Description
Order
no.
E30396
65
Process sensors
66
Process sensors
Level sensors
Process
connection
Installation
length
[mm]
Approval
Medium temperature
oils, oil-based media,
powder
Protection
Order
no.
[hazardous areas]*
12
EHEDG, FDA
-20...85 C
IP 67 / III
LMT01A
G 1/2
153
EHEDG, FDA
-20...85 C
IP 67 / III
LMT03A
G 1/2
253
EHEDG, FDA
-20...85 C
IP 67 / III
LMT04A
Accessories
Type
Order
no.
Clamp adapter
G 1/2 female Clamp 11.5
E33401
Clamp adapter
G 1/2 female Clamp 2
E33402
E30055
[V]
Current consumption
[mA]
Current rating
[mA]
< 50
100
Housing materials
Materials in contact
with the medium
E30056
T-piece, DN 25
E43316
Shock resistance
[g]
T-piece, DN 40
E43317
Vibration resistance
(LMT03A, LMT04A)
[g]
T-piece, DN 50
E43318
Vibration resistance
(LMT01A)
[g]
Welding adapter,
cylindrical, for tanks, G 1/2
E43300
Welding adapter,
cylindrical, for pipes, G 1/2
18...30 DC
Ambient temperature
50
8
20
[C]
-20...60
E43301
EN 61000-6-2
EN 61000-6-4
Screw-in adapter
G1/2 female G 3/4 male
E43302
Screw-in adapter
G1/2 female G 1 male
EMC (LMT01A)
Open tanks
Closed tanks
EN 61000-6-2
EN 61000-6-4
EN 61000-6-3
E43303
ATEX approval
Screw-in adapter
G1/2 female 3/4 NPT
group II,
category 3D / 3G
E43313
Clamp adapter,
G 1/2 female Varivent D50
E43306
Clamp adapter,
G 1/2 female Varivent D68
E43307
E43319
Description
Communication interface
IO-Link 1.1
Connection
M12 connector
Accessories
Type
Connection technology
Type
Operating voltage
Order
no.
Socket, M12,
2 m black, PUR cable
EVC04A
Socket, M12,
5 m black, PUR cable
EVC05A
Socket, M12,
10 m black, PUR cable
EVC06A
Description
Order
no.
E30390
E30396
E30398
LINERECORDER SENSOR,
Software for parameter setting and
setting up IO-Link sensors
QA0001
67
Process sensors
Application
Harsh environment conditions or high temperatures
leave the LR2050 cold. Installation in confined spaces
or detection of oils using a coaxial pipe is no problem
for LR, either. LR flexibly adapts to any application
thanks to the installation adjustment and the modular
concept.
Successful thanks to modular concept
The probes can be shortened, or changed, so the LR
reduces stock-keeping and simplifies replacement.
User-friendly setting
Even before installation the user can set the sensor
parameters via pushbuttons or IO-Link on the PC.
Installation adjustment is made on site via pushbutton,
if required.
68
Process sensors
Level sensors
Medium temperature
Protection rating/
protection class
Order
no.
[C]
Max.
tank pressure
[bar]
-20...100
-1...4
LR2050
Description
E43351
240 mm
E43203
265 mm
E43352
300 mm
E43226
450 mm
E43204
500 mm
E43227
700 mm
E43205
1000 mm
E43207
1200 mm
E43208
1400 mm
E43209
1600 mm
E43210
2000 mm
E43353
3/4" NPT
[V]
18...30 DC
Current rating
[mA]
200
Current consumption
[mA]
< 50
[s]
3
1.8...5*
>5
[C]
-40...80
Metals in contact
with the medium
Housing materials
1.1
Connection technology
Operating voltage
210 mm
E43354
240 mm
E43211
265 mm
E43355
300 mm
E43228
450 mm
E43212
500 mm
E43229
700 mm
E43213
1000 mm
E43214
1200 mm
E43215
1400 mm
E43216
1600 mm
E43217
2000 mm
E43356
450 mm
E43218
700 mm
E43219
1000 mm
E43220
1600 mm
E43221
E43333
1200 mm
E43334
Type
Description
Order
no.
EVC004
EVC005
EVC007
EVC008
IO-Link accessories
Type
Description
Order
no.
E30396
E30398
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
E43201
E43206
E43202
69
Process sensors
Maintenance-free overflow
protection to WHG*
Reliable and fast alternative
to tuning forks
Flexible installation independent of the
orientation
Shock and vibration resistant in a robust
stainless steel housing
Plug & Play Factory default setting to
hydrous media
Can be set to other media such as oil
using IO-Link
Suppression of deposits
70
Process sensors
Level sensors
Process connection
Installation length
[mm]
Medium temperature
water-based media
[C]
Medium temperature
oils, fats, bulk materials
[C]*
Order
no.
0...100
LMT191
Medium: Aqueous media Can be set to other media using IO-Link 1.1
M12 connector 4-wire DC PNP
G 1/2
12
0...85
G 1/2
38
0...85
0...100
LMT192
G 3/4
28
0...85
0...100
LMT292
G1
38
0...85
0...100
LMT392
G 1/2
153
0...85
0...100
LMT194
G 1/2
253
0...85
0...100
LMT195
* For operation to WHG
Accessories
Type
Order
no.
Operating voltage
Current rating
Screw-in adapter,
G 1/2 female G 3/4 male
E43302
Screw-in adapter,
G 1/2 female G 1 male
E43303
Screw-in adapter,
G 1/2 female 3/4 NPT
E43313
[V]
18...30 DC
[mA]
100
[C]
100
Housing materials
PEEK;
high-grade stainless steel
(316L/1.4404),
PA12, FPM
E30055
Materials in contact
with the medium
PEEK;
high-grade stainless steel
(316L/1.4404), FPM
E30056
Protection
Shock resistance
[g]
50
Welding adapter,
cylindrical, for tanks, G 1/2
E43300
Vibration resistance
[g]
20
Welding adapter,
cylindrical, for pipes, G 1/2
E43301
E43319
IP 68 / IP 69K, III
[C]
EMC
Closed tanks:
Open tanks:
0...85
EN 6100-6-2:2005
EN 6100-6-3:2006
EN 6100-6-4:2006
Accessories
Clamp adapter,
G 1/2 female Clamp 1"1.5"
E33401
Clamp adapter,
G 1/2 female Clamp 2"
E33402
E43314
E43308
Type
Description
Order
no.
E30396
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
71
Process sensors
Versatile use
Whether smaller storage tanks, compensating tanks,
separators or in filling processes: There are no limits to
applications for LR. Even adverse operating conditions
such as foam or high temperature do not affect precise
level detection.
Successful thanks to modular concept
The probes can be shortened, or changed, so the LR
reduces stock-keeping and simplifies replacement.
IO-Link means the fiddly parameter setting on the
device is a matter of the past.
Resistant materials
High-quality materials such as PEEK and EPDM as sealing
material or the high-grade stainless steel housing are
suitable for internal and external cleaning and resist the
most adverse operating conditions.
72
Process sensors
Level sensors
Process connection
Medium temperature
Protection rating/
protection class
Order
no.
[C]
Max.
tank pressure
[bar]
-40...150
-1...40
IP 69K, III
LR2750
Accessories
Type
Description
Order
no.
E43345
0.3 m,
high-grade stainless steel (316L/1.4404)
E43346
0.5 m,
high-grade stainless steel (316L/1.4404)
E43340
0.7 m,
high-grade stainless steel (316L/1.4404)
E43347
1.0 m,
high-grade stainless steel (316L/1.4404)
E43341
1.5 m,
high-grade stainless steel (316L/1.4404)
E43348
2.0 m,
high-grade stainless steel (316L/1.4404)
E43342
Operating voltage
[V]
18...30 DC
Current rating
[mA]
200
Current consumption
[mA]
< 80
[s]
3
>5
Ambient temperature
[C]
-40...80
Metals in contact
with the medium
Housing materials
1.1
Connection technology
Type
Description
Order
no.
E33212
EVT001
Pipe fitting,
DN50 (2")
E33213
EVT064
Clamp adapter,
Clamp 1-1.5"
E33201
EVT004
Clamp adapter,
Clamp 2"
E33202
EVT067
Welding adapter,
50 mm
E30122
E30396
E30398
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
IO-Link
73
Process sensors
74
Process sensors
Level sensors
Set point
accuracy
[cm]
Repeatability
[cm]
Max.
tank pressure
[bar]
Protection rating/
protection class
Order
no.
-1...4
IP 69K, III
LR9020
M12-connector
Output function 1 x IO-Link / 1 x analogue 4...20 mA / 0...10 V 4-wire DC PNP
G 3/4
1.5
0.5
Description
Stainless steel (303/1.4305)
E43203
300 mm
E43226
450 mm
E43204
500 mm
E43227
700 mm
E43205
1000 mm
E43207
1200 mm
E43208
1400 mm
E43209
1600 mm
E43210
3/4" NPT
240 mm
E43211
300 mm
E43228
450 mm
E43212
500 mm
E43229
700 mm
E43213
1000 mm
E43214
1200 mm
E43215
1400 mm
E43216
1600 mm
E43217
450 mm
E43218
700 mm
E43219
1000 mm
E43220
1600 mm
E43221
Flange plates
Flange plate, LR 73-90
E43201
E43206
E43202
Operating voltage
[V]
18...30 DC
Current rating
[mA]
200
Current consumption
[mA]
< 80
[s]
3
2...20*
> 20
[C]
0...60
Medium temperature
[C]
Metals in contact
with the medium
stainless steel
(303/1.4305), PTFE, NBR
Housing materials
Connection technology
Type
Description
Order
no.
EVC004
EVC005
EVC007
EVC008
E11231
E11232
75
Process sensors
Evaluates temperatures up to
600 C: the TR with a new look
Improved display and
evaluation unit for
Pt100 / Pt1000 sensors
Clearly indicate the acceptable ranges:
programmable red/green display
Quick and easy handling via 3 pushbuttons
with VDMA menu
Visualisation of the switching states by
clearly visible LEDs
Flexible installation thanks to modular
concept
Versions with analogue (4...20 mA / 0...10 V)
or switching output (2 x PNP/NPN)
76
Process sensors
Temperature sensors
Measuring range
Factory setting
[C]
[C]
Process connection
Pressure resistance
[bar]
Response dynamics
T05 / T09
[s]
Order
no.
-40...300
G 1/2 A
TR2439
G 1/2 A
TR7439
-40...300
Dimensions
34
Operating voltage
[V]
Current rating
18...32 DC
[mA]
250
Accuracy
[K]
Resolution display
[K]
0,1
Electrical design
PNP / NPN
Protection
64
104
M12 x1
IP 67
IO-Link
16,5
Communication interface
30
Accessories
Type
Description
Order
no.
E30420
E10017
Version
High-temperature cable sensor
Installation
length
[mm]
Order
no.
2 m,
PFA / PTFE cables
100
TS2451
2 m,
PFA / PTFE cables
150
TS2452
2 m,
PFA / PTFE cables
200
TS2453
2 m,
PFA / PTFE cables
250
TS2454
IO-Link accessories
Type
E10193
Connection technology
Type
Description
Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Description
Order
no.
E30390
E30396
E30398
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
77
Process sensors
Modern classic:
new TN temperature sensor
Even easier to use and with
improved visualisation
Measuring range of -50...150 C,
response time T05 / T09 = 1s / 3s.
Clearly indicates the acceptable ranges:
programmable red/green display
Quick and easy handling via 3 pushbuttons
with VDMA menu
Versions with analogue (4...20 mA / 0...10 V)
or switching output (2 x PNP/NPN).
Visualisation of the switching states by
clearly visible LEDs
78
Process sensors
Temperature sensors
Measuring range
Factory setting
[C]
[C]
Process connection
Pressure resistance
Response dynamics
T05 / T09
[s]
[bar]
Order
no.
-40...150
M18 x 1.5 I
300
1/3
TN2511
M18 x 1.5 I
300
1/3
TN7511
-40...150
Dimensions
34
Operating voltage
2
[V]
M12 x1
Current rating
18...32 DC
[mA]
250
Accuracy
[K]
Resolution display
[K]
0.1
140
Electrical design
14
IP 67
Communication interface
100
30
PNP / NPN
Protection
22
IO-Link
45
Connection technology
Type
Description
Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Accessories
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Type
Description
Order
no.
E30420
IO-Link accessories
Type
Description
E10017
Order
no.
E30390
E10193
E30396
E40102
E30398
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
E40104
E40096
E40099
79
Process sensors
80
Process sensors
Temperature sensors
Dimensions
Installation length
[mm]
Example TA2002
15,9
EL
18,7
M12x1
50,4
LED 2 x 180
25
TA2002
60
TA2012
1) 3/4" Clamp
Wiring diagram
1
L+
L+
IO-Link
Description
30
TA2802
50
TA2812
100
TA2832
150
TA2842
Accessories
Type
Order
no.
Order
no.
E30396
30
TA2502
50
TA2512
100
TA2532
150
TA2542
Process connection 6 mm
Temperature range (scaled 4...20 mA) -50...200 C
E30398
50
TA2212
100
TA2232
150
TA2242
QA0001
Operating voltage
[V DC]
Type
Description
Measuring element
Connection technology
Pt1000, class A
EVT001
EVT002
EVT004
EVT005
Protection
Measuring range
Accuracy
18...32
Ambient temperature
IO-Link revision
[C]
-50...200
[K]
[C]
-25...80
1.1
Materials in contact
with the medium
81
Process sensors
Versatile
The TA type temperature sensor is a universal transmitter
with a 4...20 mA current output which can be scaled
over the -50 to 150 C measuring range. Scaling is done
simply via the integrated IO-Link interface
Flexible
The compact design, the integrated process connections
and a multitude of probe lengths enable particularly
simple installation.
Transparent
An integrated LED clearly signals the readiness for
operation.
Fast and precise
A high level of accuracy is achieved using a class A
accuracy Pt1000 sensor and factory calibration.
In addition, ifms tried and tested film technology ensures
excellent dynamic response times. So this sensor is suited
for all highly precise and rapid processes.
82
Process sensors
Temperature sensors
Dimensions
TA24
EL
48
Pressure resistance
Order no.
[mm]
[bar]
Factory setting
14
18,7
M12x1
15,9
Nominal length
30
TA21
300
TA2405
50
300
TA2415
100
160
TA2435
150
160
TA2445
26
LED
-50...150 C
EL
48
13
18,7
M12x1
15,9
LED
19
0...100 C
50
300
TA2417
100
160
TA2437
150
160
TA2447
Wiring diagram
25
400
TA2105
50
400
TA2115
100
160
TA2135
150
160
TA2145
L+
-50...150 C
L+
IO-Link
Accessories
Type
Description
Order
no.
Operating voltage
[V DC]
18...32
Measuring element
IO-Link interface for parameter setting
and analysis of units with DTM
specification, current consumption
via USB port: max. 500 mA
Pt1000, class A
1s/3s
Protection
Measuring range
Accuracy
Ambient temperature
E30398
[C]
-50...150
[K]
[C]
-25...80
IO-Link revision
1.1
high-grade stainless steel
(316L/1.4404)
Device
connection
Connection technology
Type
Description
Thermowells
Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Thermowell
Order
no.
50
27
E37600
G 1/2
100
74
E37610
G 1/2
150
124
E37620
G 1/2
250
224
E37640
Dimensions
28
EL
BL
1
7
9
LINERECORDER SENSOR,
software for parameter setting and
set-up of IO-Link sensors
27
83
Process sensors
84
Process sensors
Temperature sensors
Device
connection
Thermowell
Order
no.
Process connection Tri-Clamp 1.5" for type: TA24, TT12, TT32, TM44, TD22
44,5
EL
BL
" NPS
6,6
12,7
19
26,7
6,4
38,1
G 1/2
100
64
E37810
G 1/2
150
115
E37820
G 1/2
250
191
E37830
G 1/2
350
267
E37850
63
Process connection Tri-Clamp 2" for type: TA24, TT12, TT32, TM44, TD22
44,5
EL
G 1/2
100
64
E37910
G 1/2
150
115
E37920
G 1/2
250
191
E37930
G 1/2
350
267
E37950
BL
" NPS
6,6
12,7
19
26,7
6,4
1
38,1
63
EL
BL
" NPS
G 1/2
250
191
E37430
G 1/2
350
267
E37450
6,6
16
38,1
6,4
Hygienic thermowell, process connection G 1/2 conical for type: TM45, TD25
72
EL
BL
2,5
100
68
E37511
G 1/2 conical
150
118
E37521
G 1/2 conical
50
49
E37411
G 1/2 conical
100
99
E37421
G 1/2 conical
150
149
E37431
7
9
18
G 1/2 conical
27
37
Welding clamp adapter, ball process connection 34 mm for type: TM45, TD25
41
EL
BL
34
30
2,5
16,6
Clamp fitting, process connection G 1/2 for type: TT92, TT02, TT12, TT22, TT32, TD22
13
EL
BL
1
7
9
M4
27
6 mm
50
33
E37603
6 mm
100
83
E37613
6 mm
150
128
E37623
6 mm
250
233
E37643
6 mm
350
333
E37663
Screw-in thermowell, process connection G 1/2 for type: TA24, TT02, TT12, TT22, TT32, TM44, TD22
28
EL
BL
1
7
9
27
G 1/2
50
27
E37600
G 1/2
100
74
E37610
G 1/2
150
124
E37620
G 1/2
250
224
E37640
85
Industrial communication
Safety 4.0:
the safe SmartPLC
Safe automation system
includes PLC and gateway
functions
Quick and easy set-up
Flexible and future-proof thanks to
connective hardware and CODESYS V3
High machine uptime due to sophisticated
diagnostics
Unbeatable price/performance ratio
Safe up to SIL 3, PL e
86
Industrial communication
AS-Interface Safety at Work
All-in-one
The new SmartPLC combines two separate PLCs in
one compact housing. While the one PLC solves safetyrelated applications, the second PLC either works as a
standard PLC or as platform for other tasks.
Both PLCs communicate with each other, so that entire
plant controls can be implemented including safety
functions and visualisations with only one SmartPLC.
Products
Type
Description
Order
no.
AS-i gateway
AS-i Profinet gateway
with safe preprocessing
AC402S
AC422S
Dimensions
106,2
Description
AS-i gateway
Without programming, the SmartPLC can be used
directly as a gateway for AS-i on the one side, and
Profinet or EtherNet /IP on the other side. The integrated
display and the convenient web interface display all the
available status information for the user and support
diagnostics in case of a fault.
Visualisation system
A freely programmable web visualisation based on
HTML5 provides maximum transparency. An internet
browser with HTML5 capability is sufficient on the final
unit (PC, tablet, smartphone). No further software is
required. Even the full graphic display of the SmartPLC
is freely programmable for visualisation tasks.
Accessories
Type
Standard PLC
The PLC can be freely programmed using CODESYS V3.
Its software and hardware operates independently of
the fail-safe PLC, but it can of course communicate
with it and exchange data. The PLC has access to all
interfaces of the system.
Data logger
Operational system data can be recorded via AS-i,
EtherCAT, Modbus TCP, Profinet, EtherNet /IP, TCP/IP,
UDP/IP and stored on the SD card or in the internal
flash memory.
If needed, the integrated real-time clock provides a
time stamp for each recorded data block. This simplifies
the documentation and diagnostics of processes.
128,2
135,5
93
Safe PLC
Certified up to SIL3, PL e. Eight safe local inputs and
four safe local outputs. Convenient diagnostic functions,
e.g. status indication for safe I/Os and error memory
with time stamp for up to 2,000 messages.
Programming is done via CODESYS V3. Simplified
replacement of slaves using automatic teach function.
Order
no.
AC1250
87
Industrial communication
88
Industrial communication
AS-Interface Safety at Work
The products
Type
Diagnosis on site
The LEDs indicate the status of the inputs and outputs
and the communication.
Applications
The module is designed for the connection of electrosensitive protective equipment (ESPE) with electronic
outputs to EN 61496-1. It is particularly suited for the
connection of safe inductive sensors such as GM705S.
Pulse pick-ups for the display of muting functions can
be connected via M12 sockets.
Order
no.
Safety
The module meets the requirements up to SIL3 according
to EN 62061 and PL e to EN 13849-1. In the event of a
fault, the integrated communication monitoring switches
the signal outputs off.
Description
Sensor supply
Inputs / outputs: via AS-i
Current rating inputs / outputs:
200 mA in total
Total current consumption: 280 mA
AC507S
Sensor supply
Inputs / outputs: 24 V external, PELV
Current rating inputs / outputs:
inputs 200 mA, outputs 500 mA
Total current consumption: < 80 mA
AC508S
Adapter cable,
from 8 poles to 5 poles,
M12 plug / M12 socket,
configured for automatic operation
EY3090
Adapter cable,
5 poles,
M12 plug / M12 socket,
configured for "short range"
EY3092
Adapter cable
Technical data
Safe AS-i input modules
AC507S, AC508S
Operating voltage (AS-i)
[V DC]
26.5...31.6
Short-circuit protection
Overload protection
Ambient temperature
[C]
-25...55
Protection
IP 67
AS-i profile
S-7.B.E
AS-i specification
2.11 + 3.0
Dimensions
44,7
40,2
45
103
25,8
89
Industrial communication
PLC
90
Industrial communication
IO-Link components
The products
Type
Order
no.
Unit versions
Description
Fieldbus,
PROFINET
AL1000
Fieldbus,
PROFIBUS
AL1010
Fieldbus,
EtherNet/IP
AL1020
Fieldbus,
EtherCAT
AL1030
Technical data
IO-Link master field modules
Dimensions
8,5
AL1000
6
Operating voltage
Total current consumption
1,5
[V DC]
[A]
M12x1
IO-Link version
LEDs
4+8
(IO-Link in SIO mode)
Parameter memory
Port A /port B
4/4
Protection
212
198,5
185
12
1.1
IP 65, IP 67
Ambient temperature
Housing material
30
60
18...31.2
[C]
-25...60
PA;
Socket:
Nickel-plated brass
20
30,5
91
Industrial communication
92
Industrial communication
IO-Link components
Technical data
[V DC]
18...30
IO-Link version
Type of transmission
Min. cycle time process data
2.3
Protection
IP 67
Ambient temperature
[C]
-25...70
Short-circuit protection
Overload protection
Unit versions
Dimensions
Order no.
AL2400
39
28,5
M12 sockets
Number of binary inputs
M12x1
4,5
4,7
7,5
AL2400
[mA]
Current rating
for all inputs, total
[mA]
AL2401
4x2
8x2
450
850
400
800
X1.1
X1.2
X1.3
118,2
107
M12x1
X1.0
27
23
60
AL2401
M12x1
7,5
4,5
4,7
39
28,5
X1.1
X1.2
X1.3
X1.4
X1.5
X1.6
X1.7
152
107
M12x1
X1.0
27
23
60
93
Industrial communication
94
Industrial communication
System solutions
Special features
Technical data
AY1020
AY1000
EtherNet/IP
Profinet
Further protocols
Supply voltage
[V]
18...30 DC
Current consumption
[A]
2 (24 V)
IO-Link version
1.1
Parameter memory
up to 8, configurable
IO-Link / SIO
COM 1...3
configurable
4.8k, 38.4k, 230.4kBaud
DI
8 (16) +2
DO
8+2
20
2x (10/100 BASE-Tx)
Ethernet connections
Module / Ethernet status LEDs
7
RJ45
Ethernet sockets
Electrical connections
screw terminals
IP 20
Protection
Housing material
polyamide plastics
Ambient temperature
0...70
[C]
Installation
DIN rail
PLC
server
industrial fieldbus
LR agent communication (option)
IO-Link master
IO-Link master
IO-Link
IO-Link
sensors
IO-Link
sensors
LINERECORDER
web-based
user interface
95
Industrial communication
96
Industrial communication
System solutions
Technical data
[m]
20
3-wire cable,
unscreened
[ms]
2.3
acyclic transmission
sensors 200 mA
sensors + actuators
separated
pin 1: 24 V DC
pin 3: 0 V DC
pin 4: IO-Link /
binary input / output
Order data
IO-Link service & maintenance tools
Description
Order
no.
E30396
E30390
QA0001
TP3232
TP3237
TP3231
AP3001
E30398
PLC
MODBUS -TCP
industrial fieldbus
IO-Link master
IP20
IO-Link
USB
adapter
IO-Link master
IP67
IO-Link
1
IO-Link
sensors
IO-Link
sensors
8
LINERECORDER
sensor 4.0
97
Industrial communication
Until now:
complex programming
Modern sensors offer more and more intelligent
functions that can also be made available to the PLC
via interfaces like IO-Link or TCP/IP.
To use them, the PLC programmer has to individually
implement the functionalities in the PLC. This is very
time-consuming and costly, especially when it comes
to implementing the required user interfaces.
From now on:
fit for Industry 4.0 ifm System Solutions
With the new ifm System Solution Apps ifm electronic
has developed a system which is easy to create. It allows
process data from different sensors to be transmitted to
common fieldbus systems, and their parameters are
easily accessible.
For this purpose, ifm now offers tailored apps which
can be loaded into the ifm fieldbus gateway without
any programming software.
98
Industrial communication
System solutions
The products
ifm System Solution Apps
Order
no.
AP3002
AP3022
AP3032
AP3042
AP3052
AP3062
System overview
Web- based configuration
PLC
world
analogue signals
binary signals
Sensor
world
Ethernet
AC14
TCP/IP
UDP/IP
www.ifm.com
System Solution Apps
PLC
world
PLC
Sensor
world
TCP/IP
O3D camera
AC14 with App for O3D camera
99
Identification systems
100
Identification systems
RFID 125 kHz / RFID 13.56 MHz
The products
Description
Order
no.
DTM424
DTM425
DTM434
DTM435
Connection technology
Operating voltage
Type
Description
Order
no.
[V DC]
< 50 at 24 V,
< 85 at 12 V
[mA]
Ambient temperature
Socket, M12,
2 m black, PUR cable
9...32
[C]
-40...85
EVM036
Protection rating,
protection class
IP 67 / IP 69K,
III
Socket, M12,
10 m black, PUR cable
EVM038
Housing material
stainless steel
Socket, M12,
5 m black, PUR cable
EVC492
Jumper, M12,
5 m, black, PUR cable, LED
EVC039
Interfaces
1 x CAN
CANopen
CE,
radio approval
Connection
M12 connector
Accessories
Jumper, M12,
5 m, black, PUR cable
Type
Description
EVC069
Order
no.
Display
BasicDisplay XL, 4,3",
CAN Interface
CR0452
CR1081
RFID transponders
ID tag/30X2.8/03 13.56 MHz,
16 Kbits FRAM
E80370
E80371
E80377
E80380
E80381
E80382
E80379
101
Identification systems
Reliable identification
The new robust RFID antennas have been developed
especially for the requirements in automation and
conveying technology. In combination with the antenna
adapters, they ensure excellent operating distances for
more reading reliability even under adverse installation
conditions.
The industrially compatible connection technology
"ecolink" ensures quick and reliable connection of
antennas and sensors to the RFID evaluation units.
Ready for Industry 4.0
The ifm RFID evaluation units offer a wide range of
industrial fieldbus interfaces. RFID-based identification
tasks can easily be integrated into SAP/ ERP systems.
102
Identification systems
RFID 125 kHz / RFID 13.56 MHz
Different interfaces
New: DTE104 with TCP/ IP and SAP / ERP
connectivity
This new RFID evaluation unit is ideal for direct
connection to PCs, industrial PCs or PLCs that have no
standardised fieldbus interface. Users can access all
connected antennas, sensors and actuators via TCP/IP
protocol.
The products
Description
Order no.
DTE104
DTE102
DTE101
DTE100
ANT410
ANT411
ANT420
ANT421
ANT430
ANT431
ANT512
ANT513
ANT515
ANT516
RFID antennas
Antenna adapters
Adapter to increase the ranges for
RFID antenna type M18
E80390
E80391
E80370
E80371
E80377
E80380
E80381
E80382
E80379
103
Identification systems
Industrially-compatible multicode
reader with text recognition
Extended functions for all
ifm multicode readers
Identification of 1D/2D codes and text
Optical character recognition (OCR) also
with position tracking
Variable character lengths
Easy handling
Compact industrially-compatible housing
104
Identification systems
1D/2D code readers
Type of sensor:
CMOS image sensor, black/white,
VGA resolution 640 x 480
75
Readable 2D codes
ECC200, PDF-417, QR, Micro QR, Aztec
Readable 1D codes
Interleaved 2-of-5, Industrial 2-of-5, Code 39
Code 128, Pharmacode, Code 93, Codabar
EAN13, EAN13-Add-On 2, EAN13-Add-On 5
EAN8, EAN8-Add-On 2, EAN8-Add-On 5
UPC-A, UPC-A Add-On 2, UPC-A Add-On 5
UPC-E, UPC-E Add-On 2, UPC-E Add-On 5
GS1 DataBar Omnidirectional, GS1 DataBar Truncated
GS1 DataBar Stacked, GS1 DataBar Stacked Omni
GS1 DataBar Limited, GS1 DataBar Expanded
GS1 DataBar Expanded Stacked
100
200
red light
20 x 14
28 x 20
36 x 26
68 x 50
46 x 32
61 x 44
77 x 56
140 x 100
Description
Order
no.
E2I200
E2I210
E2D110
E2D112
Clamp,
high-grade stainless steel, 12 mm
E21110
Clamp,
high-grade stainless steel, 14 mm
E21109
E21076
O2I352
infrared
20 x 14
28 x 20
36 x 26
68 x 50
O2I351
46 x 32
61 x 44
77 x 56
140 x 100
O2I353
400
Order
no.
1000
2000
40 x 30
80 x 60
80 x 60
red light
200 x 150
O2I354
400 x 300
infrared
200 x 150
400 x 300
O2I355
[V]
24 DC 10 %
Current consumption
[mA]
Current rating
Ambient temperature
< 300
[C]
-10...50
IP 67, III
Cover
Front lens
LED window
Material
diecast zinc
glass
polycarbonate
external,
24 V PNP internal,
RS-232 / TCP/IP,
EtherNet/IP
Trigger
Operating software for multicode reader
O2I350
Accessories
Type
Order
no.
max. 2 (configurable),
100 mA
24 V DC PNP
Ethernet 10Base-T /
100Base-TX, RS-232,
EtherNet/IP
Parameter /
process data interface
Dimensions
[mm]
80 x 42 x 53.5
Motion speed
[m/s]
Connection technology
Type
Description
Order
no.
Socket, M12,
2 m PUR cable, 8 poles
E11950
Socket, M12,
5 m, PUR cable, 8 poles
E11807
Protective cover/diffuser
E21165
E21166
E21168
E11898
E21169
E12090
E12204
E12205
105
106
Vibration sensor VN
Process connection via M12 x 1 and
M8 x 1 connectors
Parameter setting via PC software VES004
Configuration via sensor pushbuttons
Technical data
Vibration sensor
VNB211
Operating voltage
[V]
Dimensions
14
M12 x1
36
Input
20
5,3
2 switching outputs or
1 switching output and
1 analogue output 4...20 mA
(can be set using the
sensor pushbuttons)
Outputs
62,4
51
[mA]
Measuring range
[g]
37,6
10
M8 x1
Measurementmethod
5,3
Ring memory,
686774 data records,
with real-time clock
Data interface
USB; 2.0
Ambient temperature
2
1
Socket, M12,
2 m black, PUR cable, screened
Socket, M12,
2 m black, PUR cable, screened
Accessories
Type
Description
-30...60
IP 67
Selftest
Connection technology
Type
[C]
Protection
Wiring diagram
4
3
0...25
Vibration acceleration /
vibration velocity
History memory
5
Display
M5
9.6...30 DC
or using USB
(switching outputs not active)
Description
Order
no.
USB / M8 cable
E30136
Adapter UNF / M5
(pack quantity 10 pieces)
E30137
Power supply
E30080
Y connection cable,
M12 plug / 2 x M12 socket
E12405
Parameter software
VES004
Order
no.
EVC535
EVC532
107
108
Dimensions
Technical data
Diagnostic electronics
VSE002, VSE100
Example VSE100
50
105
Operating voltage
Ambient temperature
24 DC 20 %
IEPE input 24 DC + 20 %
[V]
[C]
0...70
Protection
Housing
35,5
114
IP 20, III
VSE002
VSE100
Inputs / Outputs
VSE002
4 dynamic inputs,
sensor type VSA/IEPE/4...20mA
in any combination
2 analogue inputs
(0/4...20 mA or pulse 24 V)
1x digital alarm output
(PNP 100 mA)
1x selectable digital
(PNP 100 mA) or
analogue (0/4...20 mA / 0...10 V)
alarm output
Inputs / Outputs
VSE100
4 dynamic inputs,
sensor type VSA/IEPE/4...20mA
in any combination
2 analogue inputs (0/4...20 mA
or 0...10 V or pulse 24 V)
1x digital alarm output
(PNP 100 mA)
1 x selectable digital
(PNP 100 mA) or
analogue (0/4...20 mA / 0...10 V)
alarm output
8 x digital outputs / inputs
(freely configurable)
(PNP 100 mA)
LEDs
1
2
1) Ethernet interface
2) Combicon connector with screw connectors (optional)
Wiring diagram
4
3
2
1
BK
BU
WH
BN
4
3
2
1
BK
BU
WH
BN
4
3
2
1
BK
BU
WH
BN
21
22
23
24
1
2
3
4
Supply L+ (24 V DC 20 %)
Supply L- (GND)
OU 1: switch/analog
OU 2: switch
17
18
19
20
5
6
7
8
IN 1 (0/4...20 mA / pulse)
GND 1
IN 2 (0/4...20 mA / pulse)
GND 2
13
14
15
16
9
10
11
12
I/O 1
GND
I/O 2
GND
25
26
27
28
48
47
46
45
I/O 7
GND
I/O 8
GND
I/O 3
GND
I/O 4
GND
29
30
31
32
44
43
42
41
I/O 5
GND
I/O 6
GND
U-OUT (0...10 V)
GND
33
34
35
36
40
39
38
37
U-IN 1 (0...10 V)
GND 1
U-IN 2 (0...10 V)
GND 2
BN
WH
BU
BK
1
2
3
4
History function
integrated
Ethernet TCP/IP,
(10 / 100 MBits)
Data interface
Accessories
Type
Description
Order
no.
Parameter software
VES004
VOS001
Connection cable
Ethernet cross-over patch cable
2 m, PVC cable,
RJ45 plug / RJ45 plug
EC2080
Connection cable
Ethernet cross-over patch cable
5 m, PVC cable,
RJ45 plug / RJ45 plug
E30112
109
Parameter setting
The new parameter software VES004 is used to set the
parameters for diagnostic electronics type VSE. With
the software it is possible to create a tree structure into
which the units and sensors are integrated. The user
can then see his own familiar structure with regards to
production sites, and machines and components.
The software contains wizard functions to simplify
creating parameter sets for vibration and process
monitoring. It is therefore possible to set up and define
simple monitoring with practically no previous expert
knowledge. Data administration such as parameter
sets, measurement data, recordings and history files
is carried out according to the pre-defined project
tree structure.
110
Object visualisation
The products
Type
Description
Order
no.
Parameter software
VES004
VOS001
VSE100
Connection cable
Ethernet cross-over patch cable
2 m, PVC cable,
RJ45 plug / RJ45 plug
EC2080
Visualisation (monitoring)
Different types of diagrammes are available for
visualising measurement values (column, tabular and
x-y diagrammes). The configuration of axes, scaling and
data sources is very flexible. For example for the x-y
diagrammes (such as history data or object measurement
values) it is possible to define several y-axes. You are
then able to easily compare the measurement values of
different sources (sensors) with different physical units
or scaling in one diagramme. The diagnostic electronic
type VSE can access all stages of the measurement
chain from the time signal (raw data) to the frequency
spectrum right through to the object values and alarm
display in order to visualise the measurement values.
The visualisation of the frequency spectrum contains
several signal analysis tools. For example measurement
lines or tools for order, harmonics and side-band analysis.
The measurement values can be recorded and stored in
the software as well as recalled and exported.
Firmware update
With the VES004 it is also possible to update the VSE
firmware. The software checks if the chosen firmware is
compatible with the unit connected and thus prevents
the use of an incorrect version.
System requirements
Windows XP (basic functions), Windows 7,
Windows 8.1
Minimum resolution 1024 x 768 pixel
256 MB RAM
111
Power management in
mobile vehicles
Modular mini controller with
high-current relay outputs
High-performance, protected relay outputs
with diagnostic function
Connection of sensors and actuators
without further external wiring
Powerful CAN interfaces for various
communication tasks
Easy installation due to adapted mechanical
ecomatmobile Basic concept
Programmable to IEC 61131-3 with
CODESYS
ecomatmobile Basic
In many small and compact mobile applications, the
requirements on control tasks are increasing.
Cost-optimised, modular mini controllers for mobile use
are in demand.
ifm offers ecomatmobile Basic consisting of the components BasicRelay, BasicController and BasicDisplay
that are adapted to each other. This BasicController
family is now complemented by the BasicController relay.
Its special feature is made up of six protected power
relay outputs with diagnostic capability for the supply
of high-current consumers in mobile machines.
In addition it has multifunctional digital and analogue
inputs that can be configured via the application software. The BasicController relay is freely programmable
via the IEC61131-3-compatible CODESYS software.
112
The products
Description
Order
no.
CR0431
EC0400
Module cover IP 54
without display recess, with cable seal
EC0401
EC0464
EC0465
EC0466
EC0467
EC2112
EC2113
CP9006
CP9008
Technical data
BasicController relay
Plastic,
potted
Housing
Device connection
Protection rating,
with cover EC0401, EC0402
Operating voltage
IP 20
IP 54
[V DC]
8...32
[mA]
45
Temperature range
Operation
Storage
[C]
[C]
-40...75
-40...85
Indicators
LED
Current consumption
Processor
Red / green
PowerPC, 50 MHz
[kB]
592
[kB]
1536
[kB]
Inputs (total):
Digital, analogue, frequency
Digital, resistance measurement
8
4
4
Outputs (total):
Micro relay ISO 7588-3,
15 A (total current max. 60 A)
Diagnostics via NO and NC contact of
the relay. Protected via mini controller
to DIN ISO 8820-3
CANopen
(DS 301 V 4.1)
SAE J 1939
free CAN protocol
Programming software
CODESYS V 2.3
CE,
E1 (UN-ECE R10)
113
Connection technology
ecolink
a new dimension in connection technology.
114
Connection technology
Sockets
Applications:
Factory automation, machine tool industry, construction of machinery, hydraulics
Approvals:
cURus
Description
LED
Order no.
2.0 m
EVC001
M12 sockets
5.0 m
EVC002
10.0 m
EVC003
2.0 m
EVC004
5.0 m
EVC005
10.0 m
EVC006
2.0 m
EVC007
5.0 m
EVC008
10.0 m
EVC009
2.0 m
EVC644
5.0 m
EVC645
10.0 m
EVC646
Dimensions
Example EVC001
15,5
14
45
M12x1
Example EVC004
15,5
26,5
36,5
Materials:
Housing / moulded body: TPU
Contact carrier: TPU
Coupling nut: diecast zinc, nickel-plated
Contacts: gold-plated
Sealing ring: Viton
Cable: PUR, halogen-free, 4 x 0,34 mm 2, 4,9 mm
Type
M12x1
14
Example EVC007
15,5
26,5
36,5
Technical data:
Operating voltage:
without LED: 250 V AC / 300 V DC
with LED:
10...36 V DC
Nominal current: 4 A (cURus 3 A)
Protection: IP 67, IP 68, IP 69K
in locked condition
with the matching counterpart.
Tightening torque nut: 0.6...1.5 Nm
Ambient temperature: -25...90 C
Vibration / shock: 750 g, 1 million cycles
Cable characteristics: drag chain > 5 million cycles
M12x1
14
3 LED
Example EVC644
15,5
3 x LED
14
45
M12x1
3 x LED
115
Connection technology
ecolink
The new dimension in connection technology.
116
Connection technology
Sockets
Technical data:
Operating voltage:
4-pole: 50 V AC / 60 V DC
5-pole: 30 V AC / 36 V DC
Nominal current: 4 A
Protection: IP 65, IP 67, IP 68, IP 69K / III
In locked condition with the matching counterpart.
Tightening torque nut: 0.6...1.5 Nm
Note the maximum value of the counterpart.
Ambient temperature:
-25...100 C, cable firmly laid
5...100 C, cable moved
Cable characteristics:
drag chain, 1 million cycles
Materials:
Housing / moulded body: PVC
Coupling nut: high-grade stainless steel
(316L / (1.4404)
Contacts: gold-plated
Sealing ring: EPDM
Cable: PVC, shielded,
4 x 0.34 mm2, 5.2 mm
5 x 0.25 mm2, 5.2 mm
Type
Connection /
cable
Number of
poles
Order
no.
2.0 m
5.0 m
10.0 m
25.0 m
4
4
4
4
EVT381
EVT382
EVT383
EVT384
2.0 m
5.0 m
10.0 m
25.0 m
4
4
4
4
EVT385
EVT386
EVT387
EVT388
2.0 m
5.0 m
10.0 m
25.0 m
5
5
5
5
EVT389
EVT390
EVT391
EVT392
2.0 m
5.0 m
10.0 m
25.0 m
5
5
5
5
EVT393
EVT394
EVT395
EVT396
2.0 m
5.0 m
10.0 m
25.0 m
4
4
4
4
EVT397
EVT398
EVT399
EVT400
2.0 m
5.0 m
10.0 m
25.0 m
4
4
4
4
EVT401
EVT402
EVT403
EVT404
2.0 m
5.0 m
10.0 m
25.0 m
5
5
5
5
EVT405
EVT406
EVT407
EVT408
2.0 m
5.0 m
10.0 m
25.0 m
5
5
5
5
EVT409
EVT410
EVT411
EVT412
Screen connected
Approvals:
cULus in preparation
Shielding characteristics
Dimensions
Example EVT381
15,5
14
x: Frequency in [MHz]
y: Shielding characteristics in [dB]
45
M12x1
Example EVT385
15,5
36,5
M12x1
26,5
14
117
Connection technology
ecolink
a new dimension in connection technology.
118
Connection technology
T splitters
Applications:
For hygienic and wet areas in the food industry
Technical data
Operating voltage:
4-pole: 250 V AC / 300 V DC
5-pole: 60 V AC / DC
Nominal current: 4 A
Protection rating: IP 67, IP 68, IP 69K
in locked condition with the matching counterpart.
Tightening torque: 0.6...1.5 Nm
Ambient temperature: -25...100 C
Type
Wiring diagram
Order no.
EBT006
EBT007
EBT008
No.
1 x M12 male, 2 x M12 female
Materials:
Housing / moulded body: PA
Coupling nut (non-rotatable):
high-grade stainless steel (316L / (1.4404)
Contacts: gold-plated
Sealing ring: EPDM
EBT009
EBT010
EBT011
Dimensions
14
M12x1
Approvals:
cRUus in preparation
38
9
21
A
C
16
48,7
M12x1
M12x1
Wiring diagram
LED
1
A
C
2
1
3
2
3
4
5
3
5
4
B
5
A
3
A
C
6
A
3
5
4
1
3
5
119
Connection technology
ecolink
a new dimension in connection technology.
120
Connection technology
T splitters
Applications:
Factory automation, machine tool industry, construction of machinery, hydraulics
Technical data
Operating voltage:
4-pole: 250 V AC / 300 V DC
5-pole: 60 V AC / DC
EBC112: 50 V AC / 60 V DC
Nominal current: 4 A (EBC112, 3A)
Protection rating: IP 67, IP 68, IP 69K
in locked condition with the matching
counterpart.
Tightening torque:
0.6...1.5 Nm (EBC112: 0.3...0.5 Nm)
Ambient temperature: -25...90 C
Type
Wiring diagram
Order no.
Order no.
No.
old
NEW
EBC112
E11562
E12165
EBC113
E10803
EBC114
E12265
EBC115
Materials:
Housing / moulded body: PA
Coupling nut (non-rotatable): CuZn / Ni
Contacts: gold-plated
Sealing ring: Viton
Approvals:
cRUus in preparation
EBC116
EBC117
EBC118
Dimensions
EBC112
Wiring diagram
14
M8x1
C
2
1
3
M8x1
16
M12x1
4,3
48,7
M12x1
3
5
M12x1
14
M12x1
4,3
48,7
3
1
16
EBC113 EBC118
B
38
38
21
21
4
B
5
A
3
A
C
6
A
3
5
4
1
3
5
121
Software
Automatic
sensor
detection
ERP
connectivity
Features
Online und offline parameter setting
Supports all IO-Link devices from ifm
Software and parameter description
in all supported languages
Detailed description texts of all parameter contents
Parameter sets grouped according to topics
Customer benefits
Optimised validation by means
of graphic visualisation of the process values
Paperless recording of parameter sets
Shortened set-up time
Optimised device replacement process
122
Traceability
Software
Parameter setting software
ERP
MES
Diagnosis
Traceability
SCADA
Machine PLC
IO-Link sensors
System requirements:
Windows XP SP3, Windows Vista SP2, Windows 7 SP1,
Windows 8, Windows Server 2008 SP2,
Windows Server 2008 R2 SP1, Windows Server 2012
CPU Intel Dual Core 2.0 GHz
2 GB RAM
5 GB free hard disk space
Web browser (Chrome, Firefox, Internet Explorer 9
upward)
Technical data
Description
LINERECORDER SENSOR
(supplied on USB flash drive)
Software for online and offline parameter setting
of ifm IO-Link sensors via USB adapter
Order
no.
QA0001
123
www.ifm.com
Information around the clock and
around the globe in 23 languages on the internet.
Information
- product innovations
- company news
- exhibition info
- locations
- jobs
Documentation
- data sheets
- operating instructions
- manuals
- approvals
- CAD data
Communication*
- request for documents
- recall service
- live advice
- newsletter
Selection
- interactive product selection aids
- configuration tools
- data sheet direct
Animation
- virtual product animations
- flash movies (video sequences)
Application
- applications
- product recommendations
- calculation aids
Transaction*
- e-shop processing
- e-procurement catalogues
124
Secured authentication
Customer-related price
indication
Management of shipping
addresses
Confirmations by e-mail
125
Overview
ifm product range:
Position sensors
Sensors for
motion control
Industrial imaging
Safety technology
Process sensors
Industrial
communication
Identification systems
Condition monitoring
systems
Systems for
mobile machines
Connection
technology
Accessories
ifm article no. 78001710 We reserve the right to make technical alterations without prior notice. Printed in Germany on non-chlorine bleached paper. 11/15