1 Please specify the dimensions and the color of the wall tiles for W13. In the legend on
the drawings they have the following dimensions: 25 cm x 150 cm and 10 cm x 30 cm,
wood finishing, but in the list of quantities it appears 37.5 cm x150 cm, RAL 8024.

2 Please specify the type, color and dimensions of tiles for the following walls: W051,
W061, W10, respectively the height to which these walls are tiled.

ceramic tiles

3 Please specify the type of tiles for B0.11 Lift lobby (building B ground floor), F05 or
F06.
4 Please specify how to quoute the positions where appears n/a: these positions dont
need to be quoted at all or it is required just the unit price.

doors

5 Please specify if the curtain walls on the ground floor and the 1st floor of the buildings B
and C must be quoted at Phase 1 or at Phase 2. In the documentation it says that these
walls are executed in the phase 1, but in the pricing schedule for the Facade Phase 2 it
appears at the posititon 19-24.

6 Please specify if there are autoclaved celular concrete walls of 40 cm. In the drawing no.
ABC_0.12, on the axis A, axis 5 and between the axis S-R apears, but in the pricing
schedule is not noted. Please send more details about these walls.

7 In the Pricing Schedule are mentioned the fire resistant curtains and we also have the
technical description, but they aren't in the joinery list. Please clarify.
doors

8 In the Pricing Schedule are mentioned glass doors but they aren't in the joinery list.
Please provide the technical specifications and the associated joinery list.
doors

doors

9 Same question as item 10 above for gthe ALA doors.


10 The fiber cement board has 4 cm thickness? We can't include this thickness in our offer.
The fiber cement boards are produced only at 1.2 cm thickness. In the project drawings
the thickness for this board is 4 cm. What material should we use or what thickness?

11 Do we have to include in our offer the interior furniture? Can you send us the details
and the technical specifications?
12 Please tell us what should we consider first: the drawings or the technical description?
Example: in drawings the floating floor has a 40 cm thickness and 30 cm in the
technical description.
13 In the agreed suppliers list we have a translucent ceiling, but they aren't in the Pricing
Schedule or in the drawings. Please clarify.
14 Can you tell us what kind of exterior floating floor should we include in our offer: a
wooden floating floor or a fiber cement floor? Send us the technical specifications.

15 Is there a plinth in the vertical circulation area (buildings A, B, C)?

16 What is the stratification of W14?


ceramic tiles

ceramic tiles

ceramic tiles

17 What are the characteristics of the ceramic finish in W24?


18 What is the floor finishing in the lift lobby area on the first floor (building B and C, plaza
level, +0.10)? Do we consider the specification provided in the architecture drawing or
the one in the corresponding flooring drawing?
19 Is there a stainless steel plinth in the open space area as stated in the pricing schedule
and technical specifications? On the plans in these rooms there is no plinth.

ceramic tiles

20 What type of floor finish is there in the Electricity room on the first floor (building B and
C, plaza level, +0.10 m)?
21 In the access lobby area (buildings B and C, ground floor and first floor) the finishes are
interlaced. Is there a detailed drawing of how the ceramics corresponding to F5 and F6
are placed? Also, what does the line surrounding the wall near the stairs mean. The line
can be found on the floor plans.

22 Where are the plasterboard trap doors (for ceilings and walls as well) positioned?

23 Is there a detailed presentation for the green retracted terraces/steps in the vicinity of
building C other than solely gradena verde in the plaza level plan?

24 Which is the uppermost level (inclusively) that is built in phase 1 for buildings B and C
structurally speaking?
25 Which is the uppermost level (inclusively) where interior finishes are executed in phase
1 in buildings B and C?
26 Which is the uppermost level (inclusively) where MEP equipments are installed in phase
1 in buildings B and C?
27 Is there a project for the design of temporary closures of buildings B and C? How are
they quantified in the pricing schedule?

ceramic tiles

28 In the lift lobby area of buildings B and C there is an inconsistency between plans and
elevations in the matter of the finishing on the walls containing the elevator doors.
What finish is intended on the wall between the 1.25 m door and the wall containing the
double door on each side?

29 What type of finish do the dot-hatched stripes on these walls and above the elevator
doors represent?
30 What is the finishing on the circumferential concrete railing in the open space?
31 What is the finishing on the outside of the core walls?

ceramic tiles

32 According to the architectural plans there seem to be several platforms for the disabled
in the underground parking spaces. If so, is there more detailed information regarding
them?
33 Is the material in 3.4.6a in the pricing schedule the same as the ceramic finish in walls
W012, W022, W031, W04 and W041? What colour is it (it is indicated as beige in the
dwgs. and RAL 1003 yellow in the pricing schedule)?

ceramic tiles

34 Is the material in 3.4.6b in the pricing schedule the same as the ceramic finish in walls
W13 and W21? What are its dimensions?
35 In the architecture Pricing Schedule, position 3.7 Other works, there are mentioned
accesories and other sanitary objects for ALA. Please tell us if they have to be included
in our offer.

36 In the Pricing Schedule the price is solicited detailed: material and (workmanship and
transport). Currently, the price is composed like this: the material contains in it the
base material and the technological loss + transport + auxiliary materials (for fitting),
and the workmanship the fitting price. Please clarify us if the transport shouldn't be
integrated in the unitary price of the material? Where will be included the technological
lost and auxiliary materials (ex.: grout, adhesive, spacers), in the material price or in
the workmanship and transport price?

37 Is the faade cleaning equipment scope of this tender? If yes, please provide us the list
of manufacturers and technical specifications.

ceramic tiles

38 Please provide details regarding the interior stairs (execution details, type of finish,
specifications) from gridlines L-K/5-6 building B -ground floor and N-O/12-13 -gorund
floor building C -entrance lobby.

ceramic tiles

39 Please clarify what finishing is requested for the interior side of the facade columns in
the entrance lobby. On drawings 1_G28_A_1_Det-Int.70-A0e is written W14. Provide us
the technical specification.

ceramic tiles

40 Regarding Phase 1- chapter ceramic tiles finishing (technical sheet no. 31, 32 and 34)
there are many discrepances between technical specifications - pag 113 and technical
specification sheet (colors, dimensions). Which is the corect one?
Ex. 1: in the tech. spec. pag. 113 - is
mentioned that W13 has dimmensions 375*1500 but in technical sheet no. 31 is
mentioned that W13 has dimmensions 300*150
Ex. 2: in the tech. spec. pag 113 - is mentioned that W23 has color wood like but in
technical sheet no. 32 is mentioned that W23 has color RAL 7036.
Ex. 3: in the tech. spec. pag 113 - is mentioned that W24 has dim. 1150*1150 and
color Ral 7036 but in technical sheet no. 34 is mentioned that W24 has dim.
1150*1130 and color RAL 7016.

41 Regarding the sheet no. 35_3.4.6.f_Wall ceramic tile.docx- show on drawing the
location.

ceramic tiles

42 Regarding the plans 2_G07_BC_0-9_Det-Int.111_A1 and 1_G19_A_2-10_Det-Int.61_


A1, clarify what type of finishing is above elevator doors and around the doors from
tenants entrance. On these drawing appear a lot of inserts in ceramic cladding, specify
the material. For new materials provide the technical specifications.

43 Please send the technical specification for the floor type F10-treated concrete screed.
44 Please clarify what finishing is requested for the storage and buffer rooms.
45 Provide us the the technical specification sheets for the platform lift for disabled acces.

46 Is the reception desk scope of this tender? If yes, send more details.
47 Ref. building A - please confirm that for execution of the technical space wall (fencing
for the equipments protection) we are using only fibrociment strips.
48 Ref. building A - please confirm that on the perimeter of the roof (attick) we shall
consider only the balustrade according the detail from the faade documentation not
any other fibrociment strips like in the architectural section.

49 Ref. item - measures for proper preservation and watertightness with corrugated metal
sheet and related metal structure -please send us more details about what type of
works we shall consider.
50 Ref. item - site accommodation for the Client and the Clients representatives according
to Client's requirements which is part of Tender Documents - do we shall consider it
like a new one or rented one?
51 Section F 09 B - please confirm the choosed system: OS 13 (Arhitectural description) or
OS 11 B ( Technical description).
52 Please confirm the dimension of dynamic cracks: 0.9 mm exceeds the Standard of OS
13. The regular Standard OS 13 overlaps only static cracks of max 0.3 mm. Must the
system overlap dynamic and static cracks? If yes, please mention the maximum
dimension. If no, please mention what cracks should it overlap (F 09 C).

53 Please confirm the system: In Arhitectural description is mentioned the Standard OS 11


B. In technical description is the OS 11 A. Having in view that the system will be
appyled outside, the recomandation is OS 11A. (F 09 D).
54 Please confirm the overlaping dimensions of cracks: 0.9 mm is the corect one? Please
specify what type of cracks are the 0.35 mm ones (dynamic, static or both). (F 09 D).
55 Please confirm the Top coat material. In Arhitectural description is mentioned a 2
component Polyurethane. In technical specification is mentioned a mono component
with 200 % elasticity as Top Coat. (F 09 D).
56 Is it a special elasticity for each product requested, or an International Standard cracks
overlaping system? If we discuss of a system, the complete system elasticity is Tested
and approved acc. International Standards (general).

57 Please indicate which is the separation point for electrical energy supply and if we have
to include in our offer the equipments from the client compartment - MV cells and
transformers.
doors

58 Please explain us what means the 20 cm indicated above the height of the doors (UEIL15, UEI-L17, UEI-L19,U-L24) in the joinery schedule.
59 According to the information received during the site visit, please confirm that the
demolishing works of the existing retaining walls next to Orhideea Commercial Center
are not in General Contractor scope of works.
60 As understood from the site visit, additional excavation and demolition works (existing
retaining walls outside the perimeter of the existing working platform) will be executed
by other Contractor, hired directly by the Client. Please inform us which will be the final
estimated excavation level after the execution of those works, from where the General
Contractor will take over the site.

61 Please provide the reinforcement excerpts and the centralizing for couplers for rebars
connections (extrase de armare si cuple).
62 Please provide steeel structure excerpts (extase laminate).
63 Regarding art. 3.2.2.1.2 in Technical Memorandum Stage 1, " certain measures will be
necessary to ensure the proper preservation of the structural joints between stage 1
and 2 and the stage 1 building watertightness". Please provide details about the above
metioned measures.
64 According art. 120 in Client's requirements - please let us know which category of
materaial/ equipment the Client intents to supply and which is the estimated percentage
from the total amount of materials/equipments to be used.
65 Please let us know if the Monitoring chapter is in General Contractor's scope of works,
as in the Monitoring schedule received with the tender documentation the monitoring
responsible is independent from the General Contractor and it's subcontractors.

66 Please inform us in which execution phase we have to include the works for Plaza Area?
67 Ref- raised floor -There is a discrepance between technical specification where is
mentioned the thickness of the panel 30 mm and attached detail from drawing
1_F03_SB_FL.41-A0 where is mentioned 40 mm. Please clarify.

68 Analyzing the documentation there are some difference between the technical
specification and plans ( Vertical sections ) for Building B and C as follows:
- In the technical specification for Building B -pag 17-we have 1 fire fight elevator with
14 stops ( from -11.45 to +36.45 m / station -2 ,-1 , 0 , 1-10 office floor , 11 technical
floor ) and 3 elevators with 11 stops ( from -3.70 to +32.40 m / station : 0 ,1-10 office
).

Analyzing the section plans for building B -drawing 2_B01_B_S.86 - A2300x85 - the
quote +36.45 corresponds to 10th floor ( from the plans result that this is the technical
floor ). Therefore the fire fight elevator will have station at -2 ,-1 , 0 , 1-9 - office , 10 technical floor ) resulting 13 stops instead of 14 stops ( mention in the technical
documentation) .
- Also the other 3 elevators from the group will have the last stop at 9 floor ( form the
plans this is the last office floor ) resulting 10 stops instead of 11 stops ( mention in the
technical documentation)
- We have the same mention for Building C .
- In the technical documentation we have 1 fire fight elevator with 14 stops and 3
elevators with 11 stops -pag 20- Analyzing the plans results that the fire fight elevator have 13 stops and the other 3
elevators from the group 10 stops.-2_B03_C_S.88 - A2300x850Please clarify.

69 Ref. section 3.3.3.1 - Floor isolation layer - Waterproofing - from Technical Specification
doc. pag. 72 - it is written: Related to: concrete slab surface under technical
rooms on building B and C, slabs in showers and all other area marked in the
Architecture drawings
Please confirm if we have to
consider all technical rooms from basement levels, typical levels and technical levels.

70 The floor type F10 on drawings (ex. drawing 1_A16_ABC_1.16-A0 and 1_A22_A_TR_22A0e) appear in staircase-landings basments and ground floors and technical rooms on
roof). For the rest of levels is F03 on drawings (ex. 1_A20_A_2_20-A0e). The details
from flooring plans (ex1_F02_B1_FL.40-A0) are attached. In the technical specification
pag. 92 there is specification for F03 - cement screed 500 mm reinforced (maybe 50
mm) and does not exist specification for F10. Please clarify the requested finishing for
the precast concrete ramp and landings for each level and for Technical rooms from
technical level.

71 Please provide the technical specification for epoxy floor in technical room from
basements.

72 Pag. 74 in technical specification - Floating concrete floor in technical rooms - on +9


floor buildings B and C - is mentioned that the slab will be painted with epoxy. Provide
the technical specs. We shall apply the same finishing also for technical rooms on +10
floor building A?

73 Please confirm that in toilets is the same ceilling like in offices, type C01. In technical
specification, pag. 131, is mentioned that the location of this type of ceilling is office
space, on plans is the same type ex. drawing 1_A16_ABC_1.16-A0.

74 Please confirm that the ceilling from technical sheet no. 47-3.5.2.d - Aluminium panels
type Co4 is installed in lift lobbies, in technical specfication, pag 133, is not mentioned
the location and the ceilling from technical sheet no. 48-3.5.2.e - Aluminium strips is
installed only in main entrance lobbies from groundfloor, in technical specification is
written - lift lobbies.
75 Please provide the technical specification for plasterboard ceilling form office space (on
perimeter), see for ex. drawing 2_E01_B_CE.101_A1.

76 Please provide the technical specification for plasterboard ceilling form entrance lobby
see for ex. drawing 2_E01_B_CE.101_A1.

doors

77 VASTINT clarification

Answer
The Ceramic Wall Tiles with wood-like finish which are marked with the code W13 are used for wall cladding in the Ground Floor Lobby Area for Buildings
A, B and C. The dimension varies due to the stereotomy of the wall cladding. (Please see A_Det-int_72 , B_Det-Int_119 or C_Det-Int_123). The color
spectrum for the ceramic wall cladding is RAL 8024.

The walls W051 and W061 have 2 major parts described in the Technical Specifications :
W051 is a autoclaved cellular concrete block wall (described in Chapter 3.1.3.a in the Technical Specifications) on which Ceramic Tiles are cladded
(described in Chapter 3.4.6.f in the Technical Specifications)
W061 is a autoclaved cellular concrete block wall (described in Chapter 3.1.3.b in the Technical Specifications) on which Ceramic Tiles are cladded
(described in Chapter 3.4.6.f in the Technical Specifications)
W10 is a gypsum board cladding covered with Ceramic Tiles (described in Chapter 3.4.6.f in the Technical Specifications).
For the type, color and dimensions of the Ceramic Tiles for the above mentioned wall cladding please see Chapter 3.4.6.f in the Technical Specifications.
For the height of the tilling on the walls please see Chapter G in the Drawing parts of the tender package:
1_G01_B2-B1_Det-Int.43
1_G02_A_SB_Det-Int.44
1_G03_A_SB_Det-Int.45
1_G04_BC_SB_Det-Int.46
*NOTE: The above mentioned Ceramic Tiles are used in the Changing Rooms and Changing Facilities in the Basement.

Please see Chapter 3.3.5.a in the Technical Specifications and Data Sheets:
8_3.3.5.a.2_F05_Floor ceramic tile
9_3.3.5.a.3_F06_Floor ceramic tile
The positions in the Pricing Schedule with n/a (not applicable) do not need to be quoted.

The curtain wall for buildings B and C will be executed in Phase 2.


*Note :* At the separations of the two phases conservation and waterproofing works will be done for buildings B and C above level 1 and the installations
will be shuttered below Ground Floor slab for buildings B and C.
** The Faade for Buildings B and C will be made of folded metal sheets (as a temporary solution for Phase 1).
In drawing no. ABC_0.12 on axis A the autoclaved cellular concrete walls are 30 cm thick and between axis S-R the walls are also 30 cm thick autoclaved
cellular concrete walls.
NOTE *There are no 40 cm thick autoclaved cellular concrete walls in the project at this moment.
For the Fire Resistant Curtain see Data Sheet 3.4.9.e_Fire Resistant screen.
The position of the is indicated in drawings:
1_A04_ABC_B2.4
1_A08_ABC_B1.8
The Fire Resistant Curtain is be quoted in the Pricing Schedule accordingly.

Please see Drawing no. H01.02. UEI 10 for the Interior Glass Doors.
Also see drawings no.:
1_A19_A_2.19
1_A20_A_3-10.20
example for the exact position.
Please see Drawing no. H01.02. U-L 14 and U-R 14 for the ALA Shelter Doors.
Also see drawing no. 1_A04_ABC_B2.4 for the exact position.
Fiber cement thickness = 1.2 cm. Acc. to architectural expression the thickness of some panels will be variable from 1.2 cm to 4 cm to have the exterior
texture.

The interior furniture is not part of the technical project and will not be included in the offer.
There is no priority of documents between the Tender documents (please see clarification note sent to the Tenderers on 09.10.2015). The correct thickness
for the office space raised floor thickness is 30 mm. Please consider Technical Specifications Chapter 3.3.8 and Data Sheet 21_3.3.8_Raised Floor for your
offer.
There is no translucent ceiling in the project, therefore it is not applicable in the Pricing Schedule.

The raised floor that the question is referring to will be fiber cement.
Please see the General Plan drawings no.:
09_GP.09
10_GP.10
11_GP.11
for more details.
If you are referring to rooms with the name Staircase/Casa scarii there is NO plinth (skirting) in these rooms.
Example :
1_A19_A_2.19
1_A20_A_3-10.20
W14 code refers to interior faade columns cladding in Acces Lobby for buildings A, B and C. W14 consists of basaltic mineral wool thermal insulations
(See Technical Specifications chapter 3.4.5) and Ceramic Tiles (code W24) mounted on a lightweight metallic structure. The finish of the W14 is ceramic
tiling, dimensions 1100 mm X 1350 mm, color RAL 7016.
Further information shall be provided in the DE project.
Dimensions for W24 are 1100 mm X 1350mm , color RAL 7016.
Further information shall be provided in the DE project.
Please see the flooring drawings 2_F01_B_FL.103 and 2_F02_C_FL.104-A0. The finish for the lift lobby area for Buildings B and C (+0.10) level is described
in the Technical Specifications in chapters 3.3.5.a.2 and 3.3.5.a.3 and Data Sheets 8_3.3.5.a.2_F05_Floor ceramic tile and 8_3.3.5.a.3_F06_Floor ceramic
tile.
In the office space area for each floor there is foreseen a stainless steel skirting according to Technical Specifications chapter 3.3.6.b.

Please see the flooring plans 2_F01_B_FL.103 and 2_F02_C_FL.104-A0. The finish for the electrical room (+0.10 m) level is described in the Technical
Specifications in chapters 3.3.5.c and Data Sheets 16_3.3.5.c._Rubber_F07.
Please see drawing referring to Detailed Floor Plan Lobby B and Lobby C for the exact stereotomy for F5 and F6 Ceramic Tiles.
Example :
2_G12_B_0_Det-Int.116
2_G16_C_0_Det-Int.120
Further information will be detailed in the DE project.

The Plasterboard trap doors (for ceiling and walls ) are not yet determined as fix positions. Taking into consideration the installation project you should be
able to estimate the number, size and position of the Plasterboard trap doors.
The detailed solution shall be provided in the DE project.
Please see General Plan drawing no.
11_GP.11
and Architecture Phase 1 drawing no.
1_B09_Plaza_S.31
The solution shall be detailed in the DE project.
The uppermost level for structural works done in Phase 1 is +4.60 m for building B and +3.90 m for building C.
The uppermost level for interior finishes done in Phase 1 is -3.95 m for building B and -4.60 m for building C.
The uppermost level for MEP equipments installed in Phase 1 is -3.95 m for building B and -4.60 m for building C.
Pricing Schedule for Phase 1 mentions in the last two rows:
Sealing with corrugated metal sheet and related metal structure Building B / Etansare cu tabla cutata cu structura metalica aferenta Corp B SQM/MP as
Unit.
Sealing with corrugated metal sheet and related metal structure Building C / Etansare cu tabla cutata cu structura metalica aferenta Corp C - SQM/MP as
Unit.
In the Prelims - pos. 11 (11.1 and 11.2) should contain the costs for such closures.
For the finish of the wall indicated please see drawing no. 2_G07_BC_0-9_Det-Int.111. The indicated finish that you are referring to is W021, Subdivision
wall, gypsum blocks, EI 180, covered in ceramic tiles 25 cm x 150 cm, wood like finish, H= 3.00 m.

The dot-hatched stripes on these walls and above the elevator doors are lighting fixtures. (LED STRIPES and PANEL).
The solution will be developed in the DE project.
In the Office Space Area the circumferential parapet finish is plaster and paint (code W011 according to architectural drawings). Please see Technical
Specifications chapter 3.4.3.a and 3.4.3.b.
The core wall exterior finish is plaster and paint. See code W011 and W02 in the section G Details Vertical Circulation core drawings. See Technical
Specifications chapter 3.4.3.a and 3.4.3.b.
Please see data sheet 75_3.7.3_Lift Platform for disabled access.

For code 3.4.6.a in Pricing Schedule please see technical specifications chapter 3.4.6.a and data sheet 30_3.4.6.a._Ceramic tiles_Toilets. More information
are provided in chapter G drawings in Toilet Stereotomy for building A in Phase 1 and Buildings B and C in Phase 2.

For code 3.4.6.b in Pricing Schedule please see technical specifications chapter 3.4.6.b and data sheet 31_3.4.6.b_W13_Wall ceramic tile. The dimension is
375 mm x 1500 mm.
Yes. Please see chapter H drawings list H3 phase 1 and Technical Specification Chapter 3.7 and Data Sheets that refer to ALA sanitary objects and
accessories.

The transport should not be integrated in the unitary price for material. The price should be split as in the BoQ.
The unit price will be split as follows:
- the price of the material (as supplied at the factory gate by the manufacturer)
and
- the costs for transporting it to the site + installation.
All other costs (auxiliary materials for fitting, etc.) are deemed to be include in the installation costs.

The cleaning of the facade will be done by alpinists. The galvanized steel structure support for alpinists must consist in:
Continous tube reccomended 89.7x6 S235J2 fixed every 1,5 m on the concrete parapet with steel plates aproximately 10 mm thickness and tubes 90x90x8
S235J2.
Tube will be placed at +41.84 m. The brackets will be considered toghether with the balustrade supports.
Dimmensioning will respect romanian local norm NSPM70.
The interior stairs from Entrance Lobby buildings B and C are build-in metallic stairs with one side stair-horse (vang lateral incastrat) and fastened on the
other side with stainless steel cables in the concrete slab. Steps will be metallic and will have the same finish as the floor of the Entrance Lobby (F06).
Further information shall be provided in the DE project.
W14 code refers to interior faade columns cladding in Acces Lobby for buildings A, B and C. W14 consists of basaltic mineral wool (see Technical
Specifications chapter 3.4.5) and Ceramic Tiles (code W24) mounted on a lightweight metallic structure. The finish of the W14 is ceramic tiling, dimensions
1100 mm X 1350 mm , color RAL 7016.
Further information shall be provided in the DE project.
31_3.4.6.b_W13_Wall ceramic tile - The Ceramic Wall Tiles with wood-like finish which are marked with the code W13 are used for wall cladding in the
Ground Floor Lobby Area for Buildings A, B and C. The dimension varies due to the stereotomy of the wall cladding. (Please see A_Det-int_72 , B_DetInt_119 or C_Det-Int_123) . The color spectrum for the ceramic wall cladding is RAL 8024.
32_3.4.6.c_W23_Wall ceramic tile.pdf- In the Technical Specification- Chapter 3.4.6. Ceramic tiles finishing- Type B it is mentioned wood like finish
according to the mockup approved, RAL 7036. In the Technical Specification Sheets - 32_3.4.6.c_W23_Wall ceramic tile it is clearly mentioned RAL 7036.
In conclusion, wood like finish is the texture of the ceramic tiles and color spectrum for the ceramic wall cladding is RAL 7036.
34_3.4.6.e_W24_Wall ceramic tile.pdf- Dimension for W24 is 1100X1350 RAL 7016.

See drawings no.:


1_A06_B_B2.06
1_A07_C_B2.07
1_A09_A_B1.09
1_A13_A_0.13
1_A14_B_0.14
1_A15_C_0.15
In Technical Specifications - Chapter 3.4.6. Ceramic tiles finishing - Type F- for changing rooms and toilettes in the basements. Tile dimensions:
100x300x7.5 mm. Material: White body wall tiles. Colour: Antracite, RAL 6034 according to the mockup approved. NOTE: dimension must be coordinated
with architecture drawings.
2_G07_BC_0-9_Det-Int.111_A1 and 1_G19_A_2-10_Det-Int.61_ A1 The above elevators doors finish (The dot-hatched stripes on these walls and above
the elevator doors) represents lighting fixtures.
Further information shall be provided in the DE project.

Please see Technical Specifications chapter 3.3.5.h.


Please see ROOM Finish Schedule present in every Architecture drawings, coordinate the information with flooring plans present in the architecture
documentation.
Please see 75_3.7.3_Platform lift for disabled access.
Technical Specification:
Vertical platform lift designed to provide easy access for the elderly or physically challenged
Dimensions: According to Architecture drawings
Travel speed: 0.04 m/s
Maximum height: 1.829 mm
Occupying minimum space without structural modification or additional building work
Further information shall be provided in the DE project.
The reception desk is not part of the technical project and will not be included in the offer.
The solution shall be developed in the DE project.
The fencing of the equipment you are referring to (on top of building A) is fiber cement panels- 28_3.4.4._Fiber cement panels mounted on a metallic
structure. Further information will be provided in the DE project.
On the perimeter of the roof (attick) you must consider only the balustrade according the details from the faade documentation. In the drawings from
chapter B_Sections Phase 1 and Phase 2 from the Architecture documentation it is presented a proposal for the advertising panels. These panels shall not
be quoted in this phase of the tender.
Further information will be provided in the DE project.
Note: * At the separations of the two phases conservation and waterproofing works will be done for buildings B and C above level 1 and the installations
will be shuttered below level 0.
** The Faade for Buildings B and C will be made of folded metal sheets (as a temporary solution for phase 1).
The solution shall be developed in the DE project.
New one, including furniture, etc.

The system that we have chosen is clearly described in Technical Specification, chapter 3.3.5. Floor finishing layers- b. Epoxy painted floor- Zone 2F09BCertificate DIN V 18026, class OS 11b (protection systems capable car park with cracks accommodate dynamic class B 3.2 (-20 C).
The system that we have chosen is clearly described in Technical Specification, chapter 3.3.5. Floor finishing layers- b. Epoxy painted floor- Zone 3-F09C
the polyurethane wear layer, two-component, without solvent, 10% elastic, able to accommodate static cracks up to 0.9 mm. Over wear layer, spread the
poured excess grain quartz sand 0.3 - 0.8 mm, to obtain a non-slip surface.
the second wear layer of polyurethane, two-component, solvent-free, 10% elastic, able to accommodate static cracks up to 0.9 mm. Over wear layer,
spread the poured excess grain quartz sand 0.3 -0.8 mm, to obtain a non-slip surface.
In conclusion, no dynamic cracks have to be taken into consideration.

The system that we have chosen is clearly described in Technical Specification, chapter 3.3.5. Floor finishing layers- b. Epoxy painted floor- Zone 4- F09 Dmultilayered polyurethane system, DIN EN 18026, class OS 11b, high capacity to accommodate dynamic cracks.

Dimension of cracks 0.9 mm at 15 C to 20 C and 0.35 mm at -20C.


The 0.35 mm cracks are static and are meant to be considered along with -20 C temperatures.
The system that we have chosen is clearly described in Technical Specification, chapter 3.3.5. Floor finishing layers- b. Epoxy painted floor- Zone 4- F09 DTop coat polyurethane elastic 200% UV resistant and weather factors, one layer, resistant to oils, fuels, de-icing agents and wear..

In the Technical Specification chapter 3.3.5. Floor finishing layers- b. Epoxy painted floor all different epoxy zones layer elasticity is described. The entire
system must be testes and meet the requirements of International Standards.

The separation point will be on medium voltage. The transformers and internal distribution from the connection point to the transformers (including any
other equipment) should be included in the offer.

Clear ISO glass.

These works should not be included in the offer at this moment. A separate offer will be requested later on if the Client will decide to include these works in
the General Contractor's scope.

The final excavation level outside the diaphragm walls on the property limit towards Carrefour will follow the existing level in Carrefour. If these works will
not be done, the retaining wall structure must be re-considered.

We can not provide. This is part of the DE design.

We can not provide. This is part of the DE design.


This section relates to the corrosion protection of the exposed reinforcement of the vertical concrete elements of buildings B and C in stage 1 and to the
temporary insulation works of the first story of B and C buildings. The protection of the reinforcement may be achieved with an appropriate cement based
mortar (e.g. Sika Monotop 910N) or by embedding the reinforcement in a low resistant concrete which will be removed before the resume of works for
stage 2. The second solution is indicated if the stage 2 will be postponed more than 2 years.
We can not indicate at the moment. The Client wishes to have the right to supply certain materials/equipments during the progress of the works.

Please include these costs in your offer. The Client will decide if this is will be kept in the scope of works of the General Contractor or will hire directly a
Monitoring Contractor independent of the General Contractor.

Works for the Plaza Area will be included in Phase 1 of the executions.
The correct dimension which you are referring to for the Office space raised floor thickness is 30 mm. Please consider Technical Specifications Chapter 3.3.8
and Data Sheet 21_3.3.8_Raised Floor for your offer.

Please take into consideration the architecture sections.


For Building A there are the following cases:
1. Fire fight lift with 13 stops / code FA1 (B2 level, B1 level, SB/level 0, level 1, level 2, level 3, level 4, level 5, level 6, level 7, level 8, level 9, level 10)
2. 2 Lift for the Basement with 4 stops / code BA7 and BA8 (B2 level, B1 level, SB/Level 0, level 1)
3. 5 Lift for the Upper Part of the building with 10 stops / code UA2, UA3, UA4, UA5, UA6 (level 1, level 2, level 3, level 4, level 5, level 6, level 7, level 8,
level 9, level 10).
For Buildings B and C there are the following cases:
1. Fire fight lift with 13 stops / code FB2/FC2 (B2 level, B1 level, level 0, level 1, level 2, level 3, level 4, level 5, level 6, level 7, level 8, level 9, technical
level)
2. 2 Lift for the Basement with 3 stops / code BB5/BC5 and BB6/BC6 (B2 level, B1 level, Level 0)
3. 3 Lift for the Upper Part of the building with 11 stops / code UB1/UC1, UB3/UC3, UB4/UC4 (Level 0, level 1, level 2, level 3, level 4, level 5, level 6, level
7, level 8, level 9, technical level 10).

According to Technical Specifications Chapter 3.3.1 - Floor isolation layer - Waterproofing - technical rooms on building B and C refers to the spaces located
on the last level - the technical level.
According to Technical Specifications Chapter 3.3.3 Floor isolation layers - Waterproofing - the waterproofing is provided in the Shower area (changing
rooms- basement) - drawings 1_F01_B2_FL.39-A0, 1_F02_B1_FL.40-A0, 1_F03_SB_FL.41-A0.

According to the Floor Plans (1_ F03_ SB_ FL.41- A0, 1_F01_B2_FL.39-A0, 1_F02_B1_FL.40-A0, 1_F04_A_FL.42-A0, 2_F01_B_FL.103-A0,
2_F02_C_FL.104-A0)
F03 represents the precast concrete treated stair and F10 represents the Staircase Landing- cement screed 50 mm thick, reinforced
The finish for the landing is the same on each level- F10- cement screed 50 mm thick, reinforced

According to drawings 1_F03_SB_FL.41-A0, 1_F01_B2_FL.39-A0 , 1_F02_B1_FL.40-A0, the epoxy paint is different depending of the basement level. The
exact type is described in the above mentioned drawings and in the Technical Specification chapter 3.3.5, Floor finishing layers_b. Epoxy painted floor, and
also in the Technical Specifications Sheets 12_3.3.5.b.1._Epoxy floor_F09A, 13_3.3.5.b.2._Epoxy floor_F09B, 14_3.3.5.b.3._Epoxy floor_F09C,
15_3.3.5.b.4.Epoxy floor_F09D_UV.
Please see Technical specification sheets -76_3.3.4_Floating concrete floor in technical rooms
Images:

Technical Specification:
Non slippery coating for floors in technical/industrial spaces which must withstand medium loads. Used for wet areas, storages and production functions.
The system will present a thickness of 2-3mm and will have the following structure:
1. Primer: EP bi-component, solvent free (total solid)
Reinforcement: sandy dried quartz, grain 0.3-0.8 mm applied evenly, not in excess
Correction layer (quartz and dry): filled 1: 0.5 to 1:1 with 0.1 mm-0.3mm quartz sand dry granulation
Reinforcement: grit dry sand 0,3-0,8 mm quartz sand
2. Pore closing layer: PU, bi-component, pigmented, solvent free, filled 1 : 0,3 cu with dried quartz sand, grain 0,1-0,3 mm
Reinforcement: grit dry sand 0,3-0,8 mm quartz or grit 0,6-1,2 mm
3. Final layer : PU, bi-component, pigmented, solvent free+ PU, bi-component, pigmented, water- based, UV resistant, satin-matt
Color: RAL 7040. Wear resistance < AR 1. Impact resistance > IR 4 .
The skirting will be made from the same system structure,

Yes, the toilets have the same type of ceiling as in the office area C01.

According to 1_A14_B_0.14-A0e, 1_A15_C_0.15-A0, 1_A16_ABC_1.16-A0 and also according to Technical Specifications chapter 3.5.2.d and 3.5.2.e, C04
is located in the entrance area and C05 is located in the elevator lobbies.

See Technical Specification Chapter 3.5.2.c Suspended ceiling- Plasterboard ceiling - plasterboard thickness of 2 x 12.5 mm (waterproof - while in areas
with high humidity).
Steel grating: a typical construction of galvanized steel sheet used to install plasterboard - according to suppliers standards.
See Technical Specification Chapter 3.5.2.c Suspended ceiling - Plasterboard ceiling - plasterboard thickness of 2 x 12.5mm (waterproof- while in areas
with high humidity).
Steel grating: a typical construction of galvanized steel sheet used to install plasterboard- according to suppliers standards.
Please note that NINZ is not an agreed manufacturer for doors and therefore should not be considered within this project.

Reference

No.
Question / Query
56 Please specify where can be found on the drawing the following position: 3.7.1 Glass
balustrade/ Balustrada sticla.

Answer
Please see drawings no.:
2_G13_B_1_Det-Int.117-A0e
2_G15_B_Det-Int.119_A1600x880
2_G17_C_1_Det-Int.121_A0e
2_G19_C_Det-Int.123_A1600x880
Also see Technical Specifications chapter 3.7.1
Images:

glass
Technical Specification:
Glass balustrade
Dimensions: according to the architectural drawings
Materilal: laminated tempered safety glass, solid aluminium floor shoe profile
Cantilevered frameless glass system
Stainless steel handrail
Fixing: according to the manufacturers recommendations
Suppliers: Glass Clever, Glass Expert, Glass Pro, Glass Tech solutions, Glass Vision Evolution
Further information shall be provided in the DE project.
70 For the glass balustrade from building B and C - entrance lobby provide technical
specification sheet and the list of manufacturers.

Please see drawings no.:


2_G13_B_1_Det-Int.117-A0e
2_G15_B_Det-Int.119_A1600x880
2_G17_C_1_Det-Int.121_A0e
2_G19_C_Det-Int.123_A1600x880
Also see Technical Specifications chapter 3.7.1
Images:

glass
Technical Specification:
Glass balustrade
Dimensions: according to the architectural drawings
Materilal: laminated tempered safety glass, solid aluminium floor shoe profile
Cantilevered frameless glass system
Stainless steel handrail
Fixing: according to the manufacturers recommendations
Suppliers: Glass Clever, Glass Expert, Glass Pro, Glass Tech solutions, Glass Vision Evolution
Further information shall be provided in the DE project.

Reference
doors

No.
Question / Query
Answer
30 Please inform us regarding the material used for "the pannel" of 20 cm width at bottom The 20 cm is a compensation panel for the doors. It has the same characteristics as the doors. (material, colour etc ).
or top of doors type UEI 13, U 14, UEI 15, UEI 17 see drawing H01.03 and H01.02.

RFI

BOQ

Code

RFI 1 - 19.10.2015
1.1

W13

1.3

F05, F06

1.16
1.28

W14 (W24)
W021

1.33

3.4.6a

1.34

3.4.6b

1.38

F06

1.40
1.40

3.4.6c
3.4.6e

1.41

3.4.6f

W23
W24

RFI 2 - 21.10.2015
2.57

3.4.6a

2.108
RFI 3 - 26.10.2015
3.27

type of stone to use for


exterior stairs

Description

Size

W13 are used for wall cladding in the Ground Floor Lobby Area for Buildings A, B and
C

The dimension varies due to the


stereotomy of the wall cladding

floor finishing in the lift lobby area on the first floor (building B and C, plaza level,
+0.10)

see Chapter 3.3.5.a in the Technical


Specifications and Data Sheets

interior faade columns cladding in Acces Lobby for buildings A, B and C


lift lobby area of buildings B and C

1100 mm X 1350 mm
25 cm x 150 cm

see technical specifications chapter 3.4.6.a and data sheet 30_3.4.6.a._Ceramic


tiles_Toilets
see technical specifications chapter 3.4.6.b and data sheet 31_3.4.6.b_W13_Wall
ceramic tile

375 mm x 1500 mm

interior stairs from gridlines L-K/5-6 building B -ground floor and N-O/12-13 -gorund
floor building C -entrance lobby

build-in metallic stairs with one side


stair-horse (vang lateral incastrat) and
fastened on the other side with
stainless steel cables in the concrete
slab

Ceramic tiles finishing- Type B


1100X1350
Ceramic tiles finishing - Type F- for changing rooms and toilettes in the basements

100x300x7.5 mm

The ceramic skirting will be included in the pricing schedule at the position 3.3.6.a
Ceramic Skirting/ Plinta ceramica for other type of ceramic tiles. The quotation will
be done as a weighted average.
(similistone) raised floor system for exterior works/general plan

600 mm x 600 mm x 20 mm

accepted Manufacturers are: GranitiFiandre, Atlas Concorde

ceramic tiles (20 mm)

Color

Finish

RAL 8024

wood-like finish

RAL 7016
wood-like finish

same finish as the


floor of the
Entrance Lobby
(F06)
RAL 7036
7016

wood-like finish

Antracite, RAL
6034

White body wall


tiles

porcelain ceramic
tile

3.3

Floors/Pardoseli

3.3.5.a.1.

F02

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.2.

F05

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.3.

F06

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.4.

F01

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.5.

F08

Gresie/Ceramic Tiles

sqm/mp

3.3.6.a

Ceramic Skirting/ Plinta cer

3.4

ml/lm

Walls and doors/Pereti si usi

3.4.6.a.

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.b.

W13

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.c.

W23

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.d.

W23

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.e.

W24

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.f.

3.4

Other works/Alte lucrari -added by Dan


Walls and doors/Pereti si usi
PG - Ceramic tile plinth
H=10cm 33X33 BAI

lm/ml

771.08

15.94

10.74

26.68

20,568.56

Marazzi-model Inside antracit


333*333

127.86

80.27

12.39

92.66

11,847.32

Marazzi/ Rectified 1500x1500


tiles

127.86

80.27

12.39

92.66

11,847.32

Marazzi/Rectifed 1500x1500 tiles

1226.61

38.69

10.74

49.43

60,629.49

marazzi -Mystone gris fleury nero


300*1200

215.37

17.90

10.74

28.64

6,167.87

marazzi stonehenge blcak


300*300

1142.52

3.87

2.45

6.32

7,218.27

268.91

18.76

11.29

30.05

8,079.67

MARAZZI- SISTEM C CITTA


100*300

218.98

44.77

12.39

57.16

12,516.02

Marazzi XL TREVERKHOME 190


x1500

591.19

59.90

12.39

72.28

42,731.80

Marazzi-Iris GRIGIO ral


7036,750*1500

0.00

0.00

0.00

0.00

0.00

14.83

41.75

12.39

54.13

802.76

Marazzi 1197*1197

683.82

21.18

12.39

33.57

22,953.10

Marazzi-Wekend Antracite
Strutturato 100*300

1.35

3.02

3,439.95

Marazzi-model Inside antracit


333*333

ari -added by Danya


1138.00

1.67

toilets offices -Dimensions/Dimensiuni


333X333X8mm
entrace lobby-Dimensions/Dimensiuni
1350X1350 mm, color/culoare RAL 7036
entrance lobby-Dimensions/Dimensiuni
1350X1350 mm, color/culoare RAL 7016
lift lobby -Dimensions/Dimensiuni
300X1200 X10.5mm
Toilets basments -Dimensions/Dimensiuni
300X300X8mm
Lift lobby-zona infrastructura,din gresie
F01

Dimensions/Dimensiuni: 100x300x7.5
mm, color/culoare RAL 1003

Dimensions/Dimensiuni: 750X1500mm,
color/culoare RAL 7036 Wood-like finish

Dimensions/Dimensiuni: 100X300mm,
color/culoare RAL 6034

3.3

Floors/Pardoseli

3.3.5.a.1.

F02

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.2.

F05

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.3.

F06

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.4.

F01

Gresie/Ceramic Tiles

sqm/mp

3.3.5.a.5.

F08

Gresie/Ceramic Tiles

sqm/mp

3.3.6.a

Ceramic Skirting/ Plinta cer

3.4

ml/lm

Walls and doors/Pereti si usi

3.4.6.a.

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.b.

W13

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.c.

W23

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.d.

W23

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.e.

W24

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.f.

Other works/Alte lucrari -added by Danya


3.3
3.3.5.a.5.

Floors/Pardoseli
F08

Ceramic Skirting/ Plinta


ceramica

3.3.6.a

3.4
3.4.6.c.

Gresie/Ceramic Tiles

sqm/mp
ml/lm

Walls and doors/Pereti si usi


W23

Ceramic tiles finishing/


Placare cu placi ceramice

sqm/mp

3.4.6.f.

Ceramic tiles finishing/


Placare cu placi ceramice
PG - Ceramic tile plinth
H=10cm 30X120 cm, colour
antracit 10.5mm
W021 - ceramic tiles 25x150
cm, wood like finish, H= 3.00
m
PG - Ceramic tile plinth
H=10cm tiles 33.3X33.3cm
colour beige

sqm/mp

ml/lm

sqm/mp

ml/lm

711.10

15.94

10.74

26.68

18,968.59

408.25

80.27

12.39

92.66

37,827.83

199.30

80.27

12.39

92.66

18,466.84

1,137.25

38.69

10.74

49.43

56,212.56

n/a

n/a

n/a

n/a

n/a

n/a

n/a

n/a

n/a

n/a

868.62

18.76

11.29

30.05

26,098.56

33.32

40.70

12.39

53.09

1,768.83

n/a

n/a

n/a

n/a

n/a

40.49

41.75

12.39

54.13

2,191.76

269.30

41.75

12.39

54.13

14,577.48

n/a

n/a

n/a

n/a

n/a

60.44

17.90

10.74

28.64

1,730.91

125.11

3.87

2.45

6.32

790.43

390.30

59.90

12.39

72.28

28,211.27

-added by Danya

161.45

18.76

12.39

31.14

5,027.71

752.32

3.87

2.45

6.32

4,753.04

585.12

44.77

12.39

57.16

33,443.12

798.73

1.67

1.35

3.02

2,414.40

Marazzi-model Inside antracit 333*333

Dimensions/Dimensiuni
333X333X8mm

Marazzi/ Rectified 1500x1500 tiles

Dimensions/Dimensiuni 1350X1350
mm, color/culoare RAL 7036

Marazzi/Rectifed 1500x1500 tiles

Dimensions/Dimensiuni 1350X1350
mm, color/culoare RAL 7016

marazzi -Mystone gris fleury nero


300*1200
n/a

Dimensions/Dimensiuni 300X1200
X10.5mm
n/a

n/a

n/a

MARAZZI- SISTEM C CITTA 100*300

Dimensions/Dimensiuni:
100x300x7.5 mm, color/culoare RAL
1003

Marazzi XL TREVERKHOME 190 x1500

Dimensions/Dimensiuni:
375X1500mm, color/culoare RAL
8024
n/a

MARAZZI XL STONE GRIGIO 1197*1197

Dimensions/Dimensiuni:
1150X1130mm, color/culoare RAL
7036

MARAZZI XL STONE ANTRACIT


1197*1197

Dimensions/Dimensiuni:
1100X1350mm, color/culoare RAL
7016

n/a

n/a

marazzi stonehenge blcak 300*300

Toilets basments
-Dimensions/Dimensiuni
300X300X8mm

Marazzi-Iris GRIGIO ral 7036,750*1500

Dimensions/Dimensiuni:
750X1500mm, color/culoare RAL
7036

MARAZZI- SISTEM C CITTA 100*300

Marazzi XL TREVERKHOME 190 x1500

Dimensions/Dimensiuni:
100X300mm, color/culoare RAL
6034

Decorfloor
F01
F02
F05, F06
faianta

06.10.2015
clasa de trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.
Floorgres Chromtech, placi ceramice dimensiune 30x30cm, grosime 10mm, clasa de trafic 33, coeficient ant
trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.
trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.

F01
F02
F05, F06
faianta

update
06.10.2015
trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.
Floorgres Chromtech, placi ceramice dimensiune 30x30cm, grosime 10mm, clasa de trafic 33, coeficient ant
trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.
trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.

F01
F02
F05, F06
faianta

update2
16.10.2015
Mirage Tribeca, placi ceramice dimensiune 30x120cm, grosime 10mm, clasa de trafic 33, coeficient anti alun
Mirage Technica, placi ceramice dimensiune 30x30cm, grosime 10mm, clasa de trafic 33, coeficient anti alu
Mirage Tribeca, placi ceramice dimensiune 120x120cm, grosime 10mm, clasa de trafic 33, coeficient anti alu
Mirage Lab 21 Collection, placi ceramice dimensiune 30x60cm, grosime 10mm, clasa de trafic 33, coeficient
delta 01.10.2015

Pazo 07.11.2015
+ email
1200x1200 mm and 600x1200 mm( Marazzi XL Stone) instead of 1350x1350 mm or 750x1500 mm . By the
you have the price of 1200x1200 mm ( 34,5 euro/sqm) the price of 1350x1350 mm cutted from 1500x1500
Pazo - oferte revizuite decembrie 2015
Pazo - 06.01.2016

0mm, clasa de trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.

0mm, clasa de trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.

clasa de trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.
, clasa de trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.
m, clasa de trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.
e 10mm, clasa de trafic 33, coeficient anti alunecare R9, clasa de foc Afl-S1.

0x1350 mm or 750x1500 mm . By the way, I never heard a standard dimension of 1350x1350 mm.
50x1350 mm cutted from 1500x1500 mm including the technical losses ( 69,5 euro/sqm!!) and 1500x1500 mm ( 49 euro/sqm) as requested.

( 49 euro/sqm) as requested.