Vous êtes sur la page 1sur 6

Auxiliary Oil Pump

Operation Procedure
Page 1 of 6

Work Instruction
G1-7009

Revision no.

Prepared by
Reviewed by
Approved by

Revision : 00
Date :

Effective date

Issue no.

DCC

Signature

Name Surname

Date

Guruh Iriyanto

06/05/2015

Auxiliary Oil Pump


Operation Procedure
Page 2 of 6
REVISION HISTORY

Rev.

Effective date

00

Revision : 00
Date :

Description of Revision
Initial Issue

Prepared

Reviewed

Approved

Auxiliary Oil Pump


Operation Procedure
Page 3 of 6

ENGLISH

BAHASA INDONESIA

1.

UNIT
Utility

1.

UNIT
Utility

2.

SYSTEM
Turbine

2.

SISTIM
Turbin

3.

SAFETY
Ensure all permits are signed off

3.

KESELAMATAN
Pastikan semua

ijin

kerja

sudah

ditandatangani
Ensure Operator is wearing

Pastikan operator menggunakan PPE

recommended PPE

yang disarankan
Semua Equipment dalam kondisi siap

Ensure All Equipment in good condition

untuk dijalankan.

and ready to start


4.

AUXILIARY OIL PUMP START UP


PROCEDURE G1-7009
Preparation:
Ensure Oil tank F1-7007 level normal
Ensure electrical power sources of oil
exhaust fan C1-7014 / C1-7015
available
Ensure all instrumentation equipment
ready
ENGLISH

Revision : 00
Date :

4.

PROSEDUR START UP AUXILIARY OIL


PUMP G1-7009
Tahap Persiapan:
Pastikan Level Oil Tank F1-7007 dalam
batas normal
Pastikan Source power untuk oil exhaust
fan C1-7014 / C1-7015 sudah tersedia
Semua

peralatan

instrument

kondisi baik
BAHASA INDONESIA

dalam

Auxiliary Oil Pump


Operation Procedure
Page 4 of 6

Pastikan Kondisi di sekitar equipment ter


Ensure around the equipment is free

bebas dari gangguan

Ensure inlet and outlet valve open

Pastikan valve inlet dan outlet sudah


terbuka

START AUXILIARY OIL PUMP G1-7009


Start Auxiliary Oil Pump G1-7009 Dari DCS

START AUXILIARY OIL PUMP G1-7009

Pindahkan Switch remote/local pada

Start Auxiliary Oil Pump G1-7009 From DCS

Change the Switch remote/local at


MCC into remote/DCS Position
Select icon Auxiliary oil pump G1-7009
on DCS display
Select start auxiliary oil pump G1-7009
from DCS
Ensure light indicator Auxiliary oil
pump

ON

G1-7009

at

display/monitor
Ensure discharge pressure auxiliary oil
pump 10.5bar-11bar and current keep
normal
Ensure Auxiliary oil pump G1-7009

MCC ke posisi remote/DCS


Pilih icon Auxiliary oil pump G1-7009
pada disply DCS
Start Auxiliary oil pump G1-7009 dari
DCS
Lihat

indikasi

pada

display

Auxiliary oil pump G1-7009 sudah jalan


Pastikan outlet press Auxiliary oil pump
G1-7009

10.5bar-11bar

dan

abnormality

such

vibration, or temperature

Revision : 00
Date :

as

current

pompa normal
Pastikan Auxiliary oil pump G1-7009
bekerja dalam kondisi normal tidak ada
abnormality baik suara, vibrasi, atau pun
temperature

started in good condition, and there are


no

bahwa

noise,
BAHASA INDONESIA

Auxiliary Oil Pump


Operation Procedure
Page 5 of 6

ENGLISH

Start Auciliary Oil Pump G1-7009 Dari Local


Pindahkan Switch remote/local pada

Start Auciliary Oil Pump G1-7009 From Local


Change the Switch remote/local at
MCC/panel into remote local Position
Start Auxiliary oil pump from local
panel
Ensure pump running and check light
indicator on local panel/MCC light On
Ensure discharge pressure auxiliary iol
pump 10.5bar-11bar and current keep
normal
Ensure Auxiliary oil pump started in
good condition, and there are no

MCC/Panel ke posisi Local


Start Auxiliary oil pump dari panel local
Pastikan

pompa

running

dan

lihat

indikasi lampu pada panel local/MCC


menyala
Pastikan outlet press Auxiliary oil pump
10.5bar-11bar

dan

current

pompa

normal
Pastikan Auxiliary oil pump bekerja
dalam

kondisi

normal

tidak

ada

abnormality baik suara, vibrasi atau pun


temperature

abnormality such as noise, vibration


or temperature
STOP AUXILIARY OIL PUMP G1-7009

STOP AUXILIARY OIL PUMP G1-7009


Stop Auciliary Oil Pump G1-7009 Dari DCS
Pindahkan Switch remote/local pada

Stop Auciliary Oil Pump G1-7009 From DCS


Change the Switch remote/local at
MCC into remote/DCS Position
Select icon Auxiliary oil pump G1-7009
on DCS display
Select stop auxiliary oil pump G1-7009
from DCS
Revision : 00
Date :

MCC ke posisi remote/DCS


Pilih icon Auxiliary oil pump G1-7009
pada disply DCS
Stop Auxiliary oil pump G1-7009 dari
DCS
BAHASA INDONESIA

Auxiliary Oil Pump


Operation Procedure
Page 6 of 6

ENGLISH

Lihat

indikasi

pada

display

bahwa

Auxiliary oil pump G1-7009 sudah stop


Ensure light indicator Auxiliary oil
pump

G1-7009

light

offat

Pastikan current Auxiliary oil pump G17009 turun (0 A)

display/monitor
Ensure pump current is decrease G17009 (0 A)

Stop Auxiliary Oil Pump G1-7009 From Local


Change the Switch remote/local at
MCC/panel into remote local Position
Stop Auxiliary oil pump G1-7009 from
local panel
Ensure pump stop and check indicator
at local panel/MCC light off
Ensure Auxiliary oil pump G1-7009
current is decrease (0 A)

Revision : 00
Date :

Stop Auxiliary Oil Pump G1-7009 Dari Local


Pindahkan Switch remote/local pada
MCC/Panel ke posisi Local
Stop Auxiliary oil pump G1-7009 dari
panel local
Pastikan pompa stop dan lihat indikasi
lampu pada panel local/MCC mati
Pastikan current Auxiliary oil pump G17009 turun (0 A)