K4WA/C
DECELERATION VALVE
SERIES 10
THREADED PORTS
p max 150 bar
Q max 40 l/min
OPERATING PRINCIPLE
PERFORMANCES
HYDRAULIC SYMBOL
bar
150
bar
0,5
l/min
40
Kg
6,8
12,0
l/min
0,05
Stroke
(from all open to completely closed)
mm
20
-20 / +50
-20 / +80
cSt
10 400
Recommended viscosity
cSt
25
Mass
kg
2,5
36 200/111 ED
1/2
K4WA/C
SERIES 10
1 - IDENTIFICATION CODE
K 4 W A / C / 10 /
Seals:
omit for mineral oils
V = viton for special fluids
Deceleration valve
Nominal size: 1/2
PRESSURE DROPSp-Q
p [bar]
Curve measured
with p 5 bar
Flow PA with
valve completely
open
4
3
2
1
0
10
20
30
40
Q [l/min]
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
Open valve
Closed valve
36 200/111 ED
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
2/2