Académique Documents
Professionnel Documents
Culture Documents
See Page
2
4
5
5
5
6
7
7
9
10
11
12
13
16
18
20
ATTENTION
SHOCK HAZARD
Labels may be located on or inside the equipment (e.g., drive or motor) to alert
people that dangerous voltage may be present.
BURN HAZARD
Labels may be located on or inside the equipment (e.g., drive or motor) to alert
people that surfaces may be dangerous temperatures.
IMPORTANT
ATTENTION
ATTENTION
WARNING
EXPLOSION HAZARD
Do not disconnect equipment unless power has been removed
or the area is known to be nonhazardous.
Do not disconnect connections to this equipment unless
power has been removed or the area is known to be
nonhazardous. Secure any external connections that mate to
this equipment by using screws, sliding latches, threaded
connectors, or other means provided with this product.
Substitution of components may impair suitability for Class I,
Division 2.
If this product contains batteries, they must only be changed
in an area known to be nonhazardous.
ATTENTION
Slide-in Writable
Label
1
N
S e
N ta tw
O tu o
D s rk
E:
M
St od
at u
us le
Module
Wiring
Diagram
Mechanical
Locking
Mechanism
Insertable I/O
Mechanical
Keying DIN Rail
Licking
Screw
RTB Removal
Handle
Removal Terminal
Block (RTB)
Interlocking Side
Pieces
Mounting
Base
WARNING
WARNING
WARNING
WARNING
Produces (Rx)
Consumes (Tx)
Where:
I1
I0
No consumed data
Produces (Rx)
Consumes (Tx)
Where:
I3
I2
I1
I0
No consumed data
Produces (Rx)
Consumes (Tx)
Where:
I7
I6
I5
I4
I3
I2
I1
I0
No consumed data
1734-IB2
Module Status
Module
Status
Network
Status
Network Status
NODE:
24VDC
Sink
Input
1734-IB8
Module
Status
Module
Status
Network
Status
Network
Status
NODE:
24VDC
Sink
Input
NODE:
24VDC
Sink
Input
Status of Input 0
Status of Input 1
Status of Input 2
Status of Input 3
1734
IB2
nput 0
NC
1734
IB4
1734
IB8
Input 1
Input 0
Input 1
Input 0
Input 1
NC
Input 2
Input 3
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7
C
V
Input = 0 and 1
NC = No Connection (2 and 3)
C = Common (4 and 5)
Input = 0, 1, 2 and 3
C = Common (4 and 5)
Input = 0, 1, 2, 3, 4, 5, 6 and 7
Note: V and C are daisychained
from either the adapter,
1734-FPD, 1734-EP24DC, or from
a user-supplied auxiliary terminal
block.
41974
WARNING
WARNING
Sink Input
In 0
In 1
NC
NC
Prox
2-wire
3-wire
V = 12/24V dc
C = Common
Channel
0
1
Prox
41966
Input
0
1
Common
4
5
Voltage
6
7
WARNING
Sink Input
0
In 0
2-wire
3-wire
In 2
Prox
In 1
Prox
In 3
Prox
41967
V = 12/24V dc
C = Common
Channel
0
1
2
3
Prox
Input
0
1
2
3
Common
4
5
4
5
Voltage
6
7
6
7
Sink Input
3-wire
3-wire
0
Prox
In 0
2-wire
Prox
3-wire
2-wire
2
In 2
In 3
2-wire
Prox
Prox
3-wire
Prox
Prox
In 1
In 4
In 5
In 6
In 7
Prox
2-wire
Prox
V
C
V = 12/24V dc
C = Common
Channel
0
1
2
3
V
41967
Input
0
1
2
3
Channel
4
5
6
7
Input
4
5
6
7
Note: When connecting more than 1 wire in a termination point, make sure
that both wires are the same gauge and type.
Publication 1734-IN051F-EN-E - August 2005
WARNING
Module
Status
Module
Status
Network
Status
Network
Status
DeviceNet
System
Power
DeviceNet
Power
1734
OB8E
7
1734
IB8
Prox
Prox
Prox
Prox
Prox
Prox
Prox
Prox
24V dc Return
24V dc
WARNING
DeviceNet
System
Power
DeviceNet
Power
Module
Status
Module
Status
Network
Status
Network
Status
1734
OB8E
7
1734
IB8
Prox
Prox
Prox
Prox
Prox
Prox
Prox
Prox
24V dc Return
24V dc
1734-IB4
Module Status
Network Status
Module
Status
Module
Status
Network
Status
Network
Status
NODE:
1734-IB8
Module Status
Network Status
NODE:
NODE:
24VDC
Sink
Input
0
Status of Input 0
Status of Input 1
Status of Input 2
Status of Input 3
1734
IB2
Module
Status
Network
Status
24VDC
Sink
Input
24VDC
Sink
Input
0
3
1734
IB4
7
1734
IB8
Indication
Module Status
Probable Cause
Off
Green
Flashing Green
Flashing Red
Red
Flashing Red/Green
Probable Cause
Off
Flashing Green
Green
Flashing Red
Red
Flashing Red/Green
Indication
I/O Status
Probable Cause
Off
Yellow
Safety Approvals
North American Hazardous Location Approval
The following information applies when
operating this equipment in hazardous
locations:
RISQUE DEXPLOSION
AVERTISSEMENT
IMPORTANT
ON-State Voltage
10V dc minimum
24V dc nominal
28.8V dc maximum
ON-State Current
2 mA minimum
4 mA nominal @ 24V dc
5 mA maximum
OFF-State Voltage
5V dc maximum
OFF-State Current
1.5 mA minimum
Input Impedance
Pointbus Current
75 mA maximum @ 5V dc
Power Dissipation
Thermal Dissipation
Isolation Voltage
(continuous voltage
withstanding rating)
50V
Tested to withstand 2500V dc for 60 s
24V dc nominal
10-28.8V dc
Indicators
Keyswitch Position
1734-IB2
0 - Input 0
2 - No Connection
4 - Common
6 - User Supply
1734-IB4
0 - Input 0
2 - Input 2
4 - Common
6 - User Supply
1734-IB8
0 - Input 0
2 - Input 2
4 - Input 4
6 - Input 6
Conductors
Wire Size
Category2
1
2
1 - Input 1
3 - No Connection
5 - Common
7 - User Supply
1 - Input 1
3 - Input 3
5 - Common
7 - User Supply
1 - Input 1
3 - Input 3
5 - Input 5
7 - Input 7
Input off-to-on filter time is the time from a valid input signal to recognition by the module. Input on-to-off time is the
time from a valid input signal to recognition by the module.
Use this conductor category information for planning conductor routing. Refer to publication 1770-4.1, Industrial
Automation Wiring and Grounding Guidelines.
Environmental Specifications
Specification
Value
Shock
Operating
Non-operating
Vibration
ESD Immunity
IEC 61000-4-2:
6 kV contact discharges
8 kV air discharges
Radiated RF Immunity
IEC 61000-4-3:
10V/m with 200 Hz 50% Pulse 100%AM at 900 Mhz
10V/m with 1 kHz sine-wave 80%AM from 30 MHz to 2000
MHz
10V/m with 200 Hz 50% Pulse 100%AM at 1890 Mhz
EFT/B Immunity
IEC 61000-4-4:
4 kV at 5 kHz on signal ports
IEC 61000-4-5:
Surge Transient
1 kV line-line(DM) and 2 kV line-earth(CM) on signal ports
Immunity
Conducted RF Immunity IEC 61000-4-6:
Emissions
CISPR 11:
Group 1, Class A
None (open-style)
Certification Specifications
Certification
Value
Certifications: (when
product is marked)1
See the Product Certification link at www.ab.com for Declaration of Conformity, Certificates, and other
certification details.
POINT I/O, POINTBus, RSLogix5, RSLogix500, and RSLogix5000, are trademarks of Rockwell Automation.
DeviceNet is a trademark of the Open DeviceNet Vendor Association.
ControlNet is a trademark of ControlNet International, Ltd.
PROFIBUS (Logo is registered, use restricted to members of PROFIBUS International only).
EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor
Association.
.
DeviceNet
Installation Assistance
If you experience a problem with a hardware module within the first 24 hours of
installation, please review the information that's contained in this manual. You can also
contact a special Customer Support number for initial help in getting your module up
and running:
United States
Contact your distributor. You must provide a Customer Support case number
(see phone number above to obtain one) to your distributor in order to
complete the return process.
PN 957974-15
Copyright 2005 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.