Vous êtes sur la page 1sur 7

C-FIX 1.18.0.

4676
Database version
2015.12.11.15.46
Date
04/02/2016

fischer fixings UK Ltd


Whitely Road; Hithercroft Industrial
Estate
Wallingford; Oxfordshire; OX10 9AT
Phone: 44-(0)-1491 827900
Fax: 44-(0)- 1491 827953
technical@fischer.co.uk
www.fischer.co.uk

Comment
LINTEL BEAM RECOMMENDATION

Design Specifications
Anchor
Anchor system
Anchor
Anchorage depth
Design Data

fischer High performance anchor FH II


High performance anchor FH II 15/10 S, zinc plated steel
70 mm
Specification by manufacturer

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including


partial safety factor for the load)

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1

C-FIX 1.18.0.4676
Database version
2015.12.11.15.46
Date
04/02/2016

Input data
Design method
Base material
Concrete condition
Reinforcement
Drilling method
Installation type
Annular gap
Type of loading
Base plate location
Base plate geometry
Profile type

Design method ENSO Mechanical


Normal weight concrete, 3000 psi, ACI 318
Cracked, dry hole
No or standard reinforcement. No edge reinforcement
Hammer drilling
Push-through installation
Annular gap not filled
Static or quasi-static
Base plate flush installed on base material
250 mm x 70 mm x 8 mm
None

Design actions *
NSd
kN

VSd,x
kN

VSd,y
kN

MSd,x
kNm

MSd,y
kNm

MT,Sd
kNm

0.00

0.00

-5.00

0.25

0.00

0.00

* The required partial safety factors for actions are included

Resulting anchor forces


Tensile action
kN

Shear Action
kN

Shear Action x
kN

Shear Action y
kN

4.04

2.50

0.00

-2.50

4.04

2.50

0.00

-2.50

Anchor no.

Force:

Tension

Compression

max. concrete compressive strain :


max. concrete compressive stress :
Resulting tensile actions :
Resulting compression actions :

0.18
5.3
8.08
8.08

N/mm
kN , X/Y position ( 0 / 0 )
kN , X/Y position ( 0 / -31 )

Resistance to tension loads


Action
kN

Capacity
kN

Utilisation N
%

Steel failure *

4.04

30.93

13.1

Pullout failure *

4.04

10.67

37.9

Concrete cone failure

8.08

12.77

63.2

Proof

* Most unfavourable anchor

Steel failure
(NRd,s)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2

C-FIX 1.18.0.4676
Database version
2015.12.11.15.46
Date
04/02/2016

NRk,s
kN

Ms

NRd,s
kN

NSd
kN

N,s
%

46.40

1.50

30.93

4.04

13.1

Anchor no.

N,s
%

Group N

Decisive Beta

13.1

N,s;1

13.1

N,s;2

NRk,p
kN

Mp

NRd,p
kN

NSd
kN

N,p
%

16.00

1.000

1.50

10.67

4.04

37.9

Anchor no.

N,p
%

Group N

Decisive Beta

1, 2

37.9

N,p;1

Pullout failure
(NRd,p)

Concrete cone failure


(NRd,c)

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)
Eq. (5.2e)

NRk,c
kN

Mc

NRd,c
kN

NSd
kN

N,c
%

19.16

1.50

12.77

8.08

63.2

Anchor no.

N,c
%

Group N

Decisive Beta

1, 2

63.2

N,c;1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3

C-FIX 1.18.0.4676
Database version
2015.12.11.15.46
Date
04/02/2016

Resistance to shear loads


Proof

Action
kN

Capacity
kN

Utilisation V
%

Steel failure without lever arm *

2.50

47.20

5.3

Concrete pry-out failure

5.00

25.54

19.6

Concrete edge failure

5.00

9.36

53.4

* Most unfavourable anchor

Steel failure without lever arm


(VRd,s)

VRk,s
kN

Ms

VRd,s
kN

VSd
kN

Vs
%

59.00

1.25

47.20

2.50

5.3

Anchor no.

Vs
%

Group N

Decisive Beta

5.3

Vs;1

5.3

Vs;2

Concrete pry-out failure


(VRd,cp)

Eq. (5.6)
Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)
Eq. (5.2e)

VRk,cp
kN

Mc

VRd,cp
kN

VSd
kN

V,cp
%

38.31

1.50

25.54

5.00

19.6

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4

C-FIX 1.18.0.4676
Database version
2015.12.11.15.46
Date
04/02/2016

Anchor no.

V,cp
%

Group N

Decisive Beta

1, 2

19.6

V,cp;1

Concrete edge failure


(VRd,c)

Eq. (5.7)

Eq. (5.7a)

Eq. (5.7b/c)

Eq. (5.7e)

Eq. (5.7f)

Eq. (5.7g)

Eq. (5.7h)

VRk,c
kN

Mc

VRd,c
kN

VSd
kN

V,c
%

14.04

1.50

9.36

5.00

53.4

Anchor no.

V,c
%

Group N

Decisive Beta

1, 2

53.4

V,c;1

Utilization of tension and shear loads


Tension loads

Utilisation N
%

Shear Loads

Utilisation V
%

Steel failure *

13.1

Steel failure without lever arm *

5.3

Pullout failure *

37.9

Concrete pry-out failure

19.6

Concrete cone failure

63.2

Concrete edge failure

53.4

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5

C-FIX 1.18.0.4676
Database version
2015.12.11.15.46
Date
04/02/2016

Resistance to combined tensile and shear loads


Utilisation steel
Eq. (5.8a)
Eq. (5.8b)
Eq. (5.9)

Utilisation concrete

Proof successful
Eq. (5.8a)
Eq. (5.8b)
Eq. (5.9)

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof
Profile type

t = 8 mm
None

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals. As fischer is not the design office, the
attached is no guarantee for incorrect input or assumptions. Any recommendations have to be approved by the
building-authority or project engineer. Results are valid only for anchor system calculated in the attached. If any
part of the system is changed, it will invalidate this report and new calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about
the stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6

C-FIX 1.18.0.4676
Database version
2015.12.11.15.46
Date
04/02/2016

Installation data
Anchor
Anchor system

fischer High performance anchor


FH II
High performance anchor
FH II 15/10 S, zinc plated steel

Anchor
Accessory

Blow-out pump ABG big


Hammer drill bit SDS Plus IV
15/100/160

Art.-No. 44887
Art.-No. 89300
Art.-No. 512609

Installation details
Thread diameter
Drill hole diameter
Drill hole depth
Anchorage depth
Drilling method
Drill hole cleaning
Installation type
Annular gap
Installation torque
Socket size
Base plate thickness
Total fixing thickness

M 10
d0 = 15 mm
h2 = 100 mm
hef = 70 mm
Hammer drilling
only blow out by hand
Push-through installation
Annular gap not filled
Tinst = 40.0 Nm
17 mm
t = 8 mm
tfix = 8 mm

Base plate details


Base plate material
Base plate thickness
Clearance hole in base
plate

Not available
t = 8 mm
df=17 mm

Attachment
Profile type

None

Anchor coordinates
Anchor no.

x
mm

y
mm

-75

75

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7