Simonazzi Motorized Valve Instruction Manual


Drive Structure
Control Card
Step Motor

Timing Belt

Screw

Springs

Controls the motor and end of stroke


sensors.
Moves the transmission system.
The step motor used, with integrated
drive, allows to reduce the dimension
and complexity of the electronic card
and improves the dynamic response of
the valve.
The timing belt transfers the rotating
movement to the screw. The timing
belt is maintenance free.
The screw converts the rotating
movement of the step motor to a linear
movement.
The springs placed in the junction
between the valve and the stem allow
to apply a force to ensure the perfect
closing of the valve.
Is important to verify the compression
of the springs to adjust the closing of
the valve without overcome the
maximum torque calculated for the
motor and transmission (see the note in
page n.3).

Electrical connections
Remove the cover of the valve to access to the
control board.
In the bottom of the board there are two
connectors with two different cables.
Externals cables connectors

J1
J3

Supply motor and control board


Cable 4 Wires + Ground (0.5 mm2)
Analog input signals and digital
input/output signals
Cable 4 Wires + Shield (0.5 mm2)

Other connectors

J4
J5
J2

Zero sensor in reverse mode


Zero sensor in direct mode
Cable supply and signals to the motor. The electrical connection of this cable is Pin To Pin (1-1, 2-2 etc.)

Simonazzi Motorized Valve Rev 0-3.doc


1/5

Rev 0.4 Eng.

Simonazzi

Calibration procedure
The calibration procedure is necessary to give the Maximum Stroke and Zero to the positioner.
The Zero point corresponds to a reference signal of 4 mA, the Maximum Stroke signal corresponds to a reference
signal of 20 mA.

Work direction
Dip Switch 4
OFF
ON

Direct (the zero position is in the lower position of the valve)


Reverse (the zero position is in the upper position of the valve)

CO2 valve
Water and Syrup valves

High and Low speed


Dip Switch 5
ON
OFF

Low speed (not used)


High speed (all the valves)

Simonazzi Motorized Valve Rev 0-3.doc


2/5

Rev 0.4 Eng.

Simonazzi
Calibration of close position
1.
2.
3.
4.
5.
6.

7.

8.

Set the switch 4 (Direct/Reverse) in the right position (see above).


Set the switches 1,6,7,8 in OFF position.
Switch on the power supply to the valve.
Delete any previous calibration of the valve restoring the factory
conditions: to do that set the switch 2 in ON position for 1 Sec.
Set ON the switch 1 in the control board.
Put the valve in the right zero position, (corresponding to an input
signal of 4 mA) with the pushbuttons UP and DOWN, paying
attention to the spring compression1 (see picture).
If the spring is too compressed is possible that the motor looses the
step; in this case bring again the Switch 1 in OFF position and repeat
the procedure from point n. 4.
Store in the eeprom memory the zero position setting ON and then OFF the switch 2 in the control board (the red
dot of the display will switch on to confirm the storage of the calibration).
Calibration of maximum opening position.

9.

Put the valve in the maximum opening position, 40 mm from the full close position, (corresponding to an input
signal of 20 mA) with the pushbuttons UP and DOWN.
10. If the physical maximum opening position is overcomed is possible that the motor looses the step; in this case bring
again the Switch 1 in OFF position and repeat the procedure from point n. 4.
11. Store in the EEprom memory the zero position setting ON and then OFF the switch 3 in the control board.
12. Set OFF the switch 1 to leave the learning mode and set ON the switch 6 to enter in automatic mode.
Check of calibration.
At the end of calibration procedure we recommend to check the calibration of the valve and the compression1 of the
spring opening and closing the valve from the PC maintenance screen; if its no good repeat the calibration.

Working Modes
Automatic Mode
Switch 6
Switch 7
Switch 8

ON
OFF
OFF

Automatic Mode active: the valve follows the analog input reference 4..20 mA
Manual Mode
Switch 6
Switch 7
Switch 8

OFF
ON
OFF

Manual Mode active: is possible to move manually the valve using the pushbuttons UP and DOWN
Test Mode
Switch 6

OFF

1 The valve is close correctly when, in the zero position, the spring is compressed about 0.5mm. Is very important to pay attention to
the spring compression during the zero position calibration, because overcoming the maximum torque is possible to damage the
transmission system and the belt of the valve; in the other hand a spring compression too low may not ensure the correct closure of
the valve.

Simonazzi Motorized Valve Rev 0-3.doc


3/5

Rev 0.4 Eng.

Simonazzi
Switch 7
Switch 8

OFF
ON

Test Mode active: the valve does full strokes between 0% and 100% position

RESET Mode
Switch 1
Switch 2
Switch 6
Switch 7
Switch 8

OFF
ON ( 1 Sec )
OFF
OFF
OFF

RESET Mode: deletes any calibration of the valve restoring the factory conditions.

Control Board
Connectors
Connector J1
Power supply connector (motor + control board)
Pin1
Pin2
Pin3
Pin4

+ 24V Step Motor


+0V Step Motor
+24V Control Board
+0V Control Board

Connector J2
Step Motor connection
Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8

COMMON (Signal)
PULSE
CW_CCW
BOOST
+24V (Motor)
+24V (Motor)
0V (Motor)
0V (Motor)

Connector J3
PLC Signals connector
Pin1
Pin2
Pin3

+ in 4..20 mA
- in 4..20 mA
Shield

Simonazzi Motorized Valve Rev 0-3.doc


4/5

Rev 0.4 Eng.

Simonazzi
Pin4
Pin5
Pin6

0V digital
Out Valve close
In Aux

LED
DL1
DL2
DL3
DL4
DL5
DL6
DL7
DL8
DL9

VCC ( +5V )
PULSE
BOOST
CW_CCW
Sensor valve close in Reverse mode (Off = sensor engaged)
Out Valve closed
Sensor valve close in Direct mode (Off = sensor engaged)
Auxiliary Input
Power (+ 24V )

DIP SWITCH
DW1
DW2
DW3
DW4
DW5
DW6
DW7
DW8
NB.

Learning Mode
Save Zero Position
Save Full Open Position
Reverse Mode
Low Speed Mode
Automatic Mode
Manual Mode
Test Mode

With switches 1 , 6 , 7 , 8 OFF and setting the switch 2 ON for 1 Sec the EEProm of the control board is
erased and all the calibrations of the valve are deleted.

DISPLAY
The display shows the state of the valve as follows:

Automatic Mode

Test Mode

Manual Mode

EEPROM Erased

Learning Mode

Position stored

Motor Connector

Simonazzi Motorized Valve Rev 0-3.doc


5/5

Rev 0.4 Eng.

Simonazzi
Front View

CONNECTOR
1
2
3
4
5
6
7
8

COMMON
PULSE
CW-CCW
BOOST
+24V
+24V
GND
GND

Simonazzi Motorized Valve Rev 0-3.doc


6/5

Rev 0.4 Eng.