Reinforcement of Branch
Connection Verification
P.G.A.Engineering
CHECKED:
APPROVED:
DATE:
4 settembre 2010
20
2
130
1
15
1
161
1
3
3
1
1
1
1
1
1
1
c
H
dR
cR
2,0
60,5
210,21
20,955
CALCULATION
Imperial
DESCRIPTION
DEF.
INPUT
Outside Diameter of Header Pipe
D
Th
Header Pipe Wall Thickness
Outside Diameter of Branch Pipe
d
Tb
Branch Pipe Wall Thickness
Corrosion Allowance
c
Design Pressure
P
PTEST
Design Pressure at Test Temperature
TMAX
Maximum Temperature
TMIN
Minimum Temperature
TTEST
Test Temperature
Eh
Header Pipe Weld Joint Factor
Sh,OP
Allowable Pipe Stress at Operating Condition
Sh,TEST
Allowable Pipe Stress at Test Temperature
Eb
Joint Efficiency Factor
Sb,OP
Allowable Pipe Stress at Operating Condition
Sb,TEST
Allowable Pipe Stress at Test Temperature
Values
16,000
0,500
6,626
0,280
0,079
1421
1668
100,4
32
68
1,0
37440
37440
1,0
37440
37440
Metric
Unit of
Measure
in
in
in
in
in
psi
psi
F
F
F
psi
psi
psi
psi
Values
406,40
12,70
168,30
7,11
2
9,80
11,50
38
0
20
1,0
258
258
1,0
258
258
Unit of
Measure
mm
mm
mm
mm
mm
MPa
MPa
C
C
C
MPa
MPa
MPa
MPa
P.G.A. Engineering di Provini Gabriele - Via Emilia Parmense, 42 - 29010 Fontana Fredda di Cadeo (PC)
Tel./Fax: +39 0523 072430 - E-mail info@pgaengineering.it - Web: http://www.pgaengineering.it
P.G.A.Engineering
PREPARED:
Reinforcement of Branch
Connection Verification
CHECKED:
APPROVED:
4 settembre 2010
DATE:
DEF.
Values
OUTPUT
th,OP
Minimum Header Thickness at Operating Condition
0,304
Minimum Header Thickness at Test Condition th,TEST
0,356
th
Minimum Header PipeThickness Required
0,435
th,G
Minimum Header Pipe Thickness Garanteed
0,438
tLS,OP
Minimum Branch Thickness at Operating Condition
0,126
Minimum Branch Thickness at Test Condition tLS,TEST
0,148
tb
Minimum Branch Pipe Thickness Required
0,226
tb,G
Minimum Branch Pipe Thickness Garanteed
0,245
Required Area Coefficient
K
0,876
Maximum Height of the Reinforcement Zone
L
1,781
r1
Maximum Half-Width of the reinforcement Zone
6,066
Reinforcement Area Required
A
2,339
A1
Area Resulting from an excess th in Header Pipe
0,015
A2
Area Resulting from an excess th in Brench Pipe
0,066
A3
Additional Reinforcement Area Required
2,25842
dR,MIN
Minimum Nipolets Exthernal Diameter
8,28
cR,MAX
Maximum Chamfer Height
0,82
A3,EFF
Effective Reinforced Area Added
2,25842
Weldolet or Nipolets Diamension
Weldolet or Nipolets Height
Weldolet or Nipolets Exthernal Diameter
Chamfer Height
H
dR
cR
2,38
8,28
0,83
Metric
Unit of
Measure
in
in
in
in
in
in
in
in
in
in
Values
Unit of
Measure
in2
7,71
9,05
11,05
11,11
3,19
3,75
5,75
6,22
0,88
45,2438
154,08
1509,15
9,36
42,75
1457,04
210,210
20,955
1457,04
mm2
mm2
mm2
mm2
mm
mm
mm2
in
in
in
60,50
210,21
20,96
mm
mm
mm
in2
in2
in2
in2
in
in
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
VERIFICATION
Description
Formula
CHECK
th,G th
VERO
tb,G tb
VERO
VERO
HL
VERO
dR 2 r 1
VERO
Diameter Verification
dR dR,MIN
VERO
Chamfer Verification
cR cR,MAX
VERO
A3,EFF A3
VERO
P.G.A. Engineering di Provini Gabriele - Via Emilia Parmense, 42 - 29010 Fontana Fredda di Cadeo (PC)