ITEM

JOB N0
OFFICE BUILDING

C EXISTING SITE /
BUILDINGS / SERVICES

BILL Nr. 2 - OFFICE BUILDING


C EXISTING SITE / BUILDINGS / SERVICES
The Contractor is advised to visit the site, carefully
examine the items to be demolished, types of
construction etc. and to study the implication of such
demolition and the clearing away of the debris
The Contractor shall allow in its prices the protection
of adjacent buildings during excavation and/or
construction, the protection and maintenance of all
pipes ducts, and cables met in excavation; keeping
all ditches, gullies and channels clear and
unobstructed and making good any damage caused to
public road, kerbs and drains and paying all cost and
and charges incurred
Note: Salvaged materials shall be set aside and shall only
be disposed of upon receipt of instructions from the
Architect. In no case shall the credit value of salvaged
materials be deducted from the rates of items in demolitions
to show a net figure
The works in this section consists of demolition and
alteration of existing four storey concrete framed structure
with sandcrete blockwork enclosure and partition. The
building measure 18.90 x 8.25 x 16.0m high

C20 DEMOLITIONS
Demolishing individual structures and dispose
A

200mm thick sandcrete block wall [ 539 m2 ]

Item

Reinforced concrete staircase, gutter and slab


[ 27 m3 ]

Item

C90 ALTERATIONS - SPOT ITEMS


Removing fittings and fixtures and pack on site for client
C

hardwood panelled door and frame size 900mm


2100mm high [ 32 Nr ]

Item

Glazed aluminium door and attached window and size


2000mm x 1200mm high [ 36 Nr ]

Item

Ditto size 1000mm x 750mm high [ 20 Nr ]

Item

Page N0
2/1

Carried to Collection
ITEM

JOB N0 Page N0
OFFICE BUILDING

SUBSTRUCTURE

C90 Alteration - Spot Items (Cont'd)


Removing fittings and fixtures and pack on site for client
A

Water closet complete with cistern [ 16 Nr ]

Item

Wash hand basin [ 16 Nr ]

Item

Electrical switches, sockets and light fittings including


wiring point [ 486 Nr ]

Item

Removing finishings and dispose


D

Ceramic Floor tiling including screeding [ 698 m2 ]

Item

Removing covering and pack on site for client


E

Aluminium sheet roofing with hardwood carcassing


[ 237 m2 ]

Item

Plywood ceiling and noggings [ 175 m2 ]

Item

Cutting openings or recess, make good all work disturbed


200mm thick solid sandcrete blockwall, size
G

2000mm x 1500mm high [ 4 Nr ]

Item

1000mm x 750mm high [ 16 Nr ]

Item

1000mm x 2100mm high [ 12 Nr ]

Item

Carried to Collection

COLLECTION
Page Nr. 2/1
Page Nr. 2/2

C EXISTING SITE / BUILDINGS / SERVICES


To Summary of Bill Nr. 2

2/2

ITEM

JOB N0 Page N0
OFFICE BUILDING

GROUND WORK

SUBSTRUCTURE
GROUND WORK
D20 EXCAVATION AND FILLING
Excavating
Pits
A

maximum depth not exceeding 1.00m [ 8 Nr.]

8 m3

Trenches
B

width exceeding 300mm; depth not exceeding 2.00m

3 m3

Disposal
C

Excavated materials off site

7 m3

Filling to excavations
D

average thickness > 0.25m; arising from excavations

4 m3

Filling to Make up Levels


E

average thickness > 0.25m; imported laterite deposited


in layers 150mm maximum thick and compacted

2 m3

Surface treatment
F

Prepare and apply dieldrex anti-termite treatment


solution to surfaces of excavations

GROUND WORK
To Summary of Bill Nr. 2

52 m2

2/3

ITEM

JOB N0
OFFICE BUILDING

E IN-SITU CONCRETE/
LARGE PRECAST
CONCRETE

E. IN-SITU CONCRETE /LARGE PRECAST CONCRETE


E.10 IN-SITU CONCRETE
Plain in-situ concrete 10N/mm 2-All in Aggregate:Blinding bed
A

thickness 150mm; poured on or against earth or


unblinded hardcore

1 m3

Reinforced in-situ concrete 25N/mm2-20mm Aggregate:Isolated foundations


B

generally

2 m3

Ground beams
C

generally

4 m3

Slabs
D

thickness 150 - 450mm

4 m3

Beams
E

isolated

7 m3

attached

2 m3

Columns
G

generally

2 m3

E.20 FORMWORK FOR IN-SITU CONCRETE


Sawn formwork; coating with release agent
Sides of foundations
H

height; 250 - 500mm

29 m

Sides of ground beam and edges of bed


J

height; 500 - 1000mm

36 m

Page N0
2/4

Edges of suspended slabs; plain vertical


K

22 m

height; 200mm

Carried to Collection
ITEM

JOB N0
OFFICE BUILDING

E In-situ Concrete/
Large Precast Concrete
(Cont'd)

E.20 Formwork for In-situ Concrete (Cont'd)


Sawn formwork; coating with release agent
Soffits of slabs
A

thickness 200mm; height to soffit 3.00 - 4.50m;


horizontal

21 m2

Beams
B

attached to slabs; rectangular; height to soffit 1.50 3.00m; [ 5 Nr ]


isolated; rectangular; height to soffit 1.50 - 3.00m;
[ 37 Nr ]

21 m2

120 m2

Columns
D

isolated; rectangular shaped [ 26 Nr]

29 m2

E.30 REINFORCEMENT FOR IN-SITU CONCRETE


Reinforcement; BS 4449 hot rolled deformed round high
tensile steel; yield strength 460N/mm2
Bars; straight, bent and curved
E

20mm diameter; ground beam

0.17 t

16mm diameter; ground beam

0.14 t

16mm diameter; column bases

0.17 t

16mm diameter; column

0.38 t

16mm diameter; beam

1.45 t

12mm diameter; slab

0.55 t

10mm diameter links; ground beam

0.10 t

10mm diameter links; beam

0.53 t

10mm diameter stirrups; column

0.11 t

Page N0
2/5

Carried to Collection

ITEM

JOB N0
OFFICE BUILDING

COLLECTION
Page Nr. 2/4
Page Nr. 2/5
E. IN-SITU CONCRETE /LARGE PRECAST CONCRETE
To Summary of Bill Nr. 2

E In-situ Concrete/
Large Precast Concrete
(Cont'd)

Page N0
2/6

ITEM

JOB N0
OFFICE BUILDING

F MASONRY

F. MASONRY
F10 BRICK / BLOCK WALLING
Hollow sandcrete lightweight aggregate, blocks, 450 x 225
(Minimum Crushing strength: 2.5N/mm2); in cement mortar
(1:4);
Walls
A

150mm thick

F. MASONRY
To Summary of Bill Nr. 2

435 m2

Page N0
2/7

ITEM

JOB N0
OFFICE BUILDING

G STRUCTURAL /
CARCASSING METAL /
TIMBER

G. STRUCTURAL / CARCASSING METAL / TIMBER


G10 STRUCTURAL STEEL FRAMING
Steel link bridge spanning 7.0m long x 2.0m wide x
2.0m high and hoisted 7.0m above ground level
[ 1 Nr ]
Fabricated; Spec 254 x 146 x 31 UB to BS 4360;
Grade 43
A

Columns
weight not exceeding 40 kg/m

1.14

Beams
weight not exceeding 40 kg/m

1.86 t

Fabricated; Spec 100 x 100 x 8 Angles to BS 4360;


Grade 43

Bracings
weight not exceeding 40 kg/m

0.29 t

Fabricated; Spec 40mm diameter x 3.2mm galvanised


pipes to BS 4360; Grade 43
Guard rails
D

weight not exceeding 40 kg/m

0.20 t

Fabricated; Spec 6mm sheet plate to BS 4360;


Grade 43
Floors
E

weight not exceeding 40 kg/m


Permanent erection on site including supplying
and installing member connections

0.66 t

Page N0
2/8

welded and bolted connection and hoisting 18,380mm


above ground level

4.15 t

Mild steel round bar:


Holding down bolts with nuts and washers
G

20mm diameter x 350mm long

16 Nr

Surface treatment
Red oxide protective painting
H

Two coats spray painted prior to fixing

150 m2

Carried to Collection
ITEM
OFFICE BUILDING

G Structural /
Carcassing Metal /
Timber
(Cont'd)

G20: CARPENTRY/TIMBER FRAMING/FIRST FIXING


Sawn hardwood in 'Odum' species or other approved equal:
treated with clear solignum preservative
Trussed rafters; dual pitched top chord
A

Triangulated plane pattern; 50x150mm members,


comprising 2Nr top chord, 2Nr bottom chord, 6Nr ties,
4Nr struts; jointed with 16mm diameter bolts, nuts and
washers; overall size 10,250 x 2,390mm high; hoisting
16,000mm above ground level

4 Nr

Roof members; pitched


B

50 x 75mm

376 m

50 x 150mm

340 m

Butt jointed supports


D

width > 300mm; 50 x 75mm members at 600mm centres


one way; 50 x 50mm subsidiary members at 600mm
centres one way; fixing to masonry

245 m2

Individual support
E

50 x 50mm

183 m

Wrought hardwood in 'Odum' species or other approved


equal; treated with preservative
Fascia and barge boards
F

width 300, 25 x 300mm wide

76 m

JOB N0

Page N0
2/9

PVC tongued and grooved strip ceiling 10mm thick nailed to


hardwood (measured separately)
G

Eaves and verge soffit boarding

61 m2

Carried to Collection

COLLECTION
Page Nr. 2/8
Page Nr. 2/9
G. STRUCTURAL / CARCASSING METAL / TIMBER
To Summary of Bill Nr. 2
JOB N0

ITEM
OFFICE BUILDING

H CLADDING / COVERING

H CLADDING / COVERING
H11 - CURTAIN WALLING
Curtain walling panel with narrow powdered coated
aluminium profiles flush mounted Pilkington insulight
double glazing with 6mm Pilkington optitherm SN
laminated inner pane and Pilkington opitfloat grey body
tinted laminated outer pane and 16mm air filled cavity
(opitfloat 75/59) Allow for top hung projected vents in
locations shown in accompanied drawings
Wall cladding fabricated to flat, smooth
A

Plain vertical

228 m2

Openings extra over the partitions in which they occur


B

Pivoted window; overall size 600 x 600mm high

H31 METAL PROFILED / FLAT SHEET CLADDING /


COVERING/ SIDING
Design, supply and install Aluminium composite cladding
of Alucobond/ Alstrong/Durabuilt or equivalent make
in metallic colours using prefabricated aluminium extruded
profiles of Alloy 6063 T6 in achromatized finish to
withstand the design wind pressure as per IS. The
fastening brackets of Aluminium / Hot dip galvanized with
SS 304 screws, fasteners and anchor bolts complete with
nylon separators to prevent bi metallic contacts.
Stiffener of 50 x 25 tubes shall be attached to the panel at
the panel centre with the help of two sided adhesive tape
and sealant. Minimum one stiffener per panel to be

17 Nr

Page N0
2/10

provided if required. Panel size 600 x 600mm


Wall cladding fabricated to flat, smooth
C

Plain vertical

401 m2

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

H Cladding / Covering
(Cont'd)

H72 - ALUMINIUM SHEET COVERINGS / FLASHING


0.6mm Pre-painted IDT longspan aluminium roofing sheet
with two crests side lap and nailed to hardwood with
galvanised screws in accordance with manufacturer's
specification
Roof coverings
A

pitch; 25

254 m2

Ridges
B

450 girth; dressing over corrugated roofing

18 m

Cappings
C

450 girth; dressing over corrugated roofing

Carried to Collection

COLLECTION
Page Nr. 2/10
Page Nr. 2/11

31 m

Page N0
2/11

H CLADDING / COVERING
To Summary of Bill Nr. 2

JOB N0

ITEM
OFFICE BUILDING

J WATERPROOFING

J WATERPROOFING
J31 - LIQUID APPLIED WATERPROOF ROOF COATINGS

Decadex waterproofing; Dygate Ghana Ltd., Tel. 030


3227990, one coat LPL Bonding Primer 0.16 litre/m 2
covering with one coat embedment of "decadex" membrane
1litre/m2; Reemat Glass Fibre Mat; one coat finishing coat of
'decadex' membrane 0.75 litre/m 2 or other equal and
approved type

Tanking and damp proofing; to concrete base


A

Flat; horizontal

Flat; vertical

J WATERPROOFING
To Summary of Bill Nr. 2

21 m2
3 m2

Page N0
2/12

JOB N0

ITEM
OFFICE BUILDING

K LINING / SHEATING /
DRY PARTITIONING

K LININGS / SHEATING / DRY PARTITIONING


K10 PLASTERBOARD DRY LINING / PARTITIONS /
CEILINGS
12mm gypsum plaster board partitioning fixed to aluminium
stud framing with drive screws and joints filled with tape and
compound and skimming
Proprietary partitions
A

Height 3200mm, 125mm thick; boarded on both sides

60 m

Openings extra over the partitions in which they occur


B

Door opening; overall size 1,000 x 2,100mm high

6 Nr

12mm moisture resistant gypsum plaster board fixed to


hardwood framing(measured separately) with drive screws
and joints filled with tape and compound and skimming
Linings
C

Ceilings

143 m2

Page N0
2/13

Suspended circular bulkhead comprising of 12.5mm thick


two level gypsum plasterboard suspended ceiling fixed onto
75mm wide galvanised iron main & furring channel
framework. The finished ceiling should be taped, skimmed &
sanded smooth for the final finishes. Allow for recessed
pelmets & cut-outs for light fixtures, and all openings
required for electrical, HVAC & fire detection.

Ceilings; rectangular shaped 3300mm x 3800mm x 400mm


deep
Depth of suspension 150 - 500mm

1 Nr

K30 PANEL PARTITIONS


Glazed Wall Partitions
Glazed Wall Partitions, 8mm thick tempered glass in natural
anodised aluminium frames. Width dimensions as per layout
with modular glass panel; provide frosted vinyl
sticker/sunguard with horizontal pattern.
Partitions
F

10 m

3200mm high

GH

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

K Lining / Sheating /
Dry Partitioning
(Cont'd)

Glazed Wall Partitions (Cont'd)


Openings extra over the partitions in which they occur
A

Glazed aluminium door in natural anodized profiles and


pre-glazed with 6mm plain sheet glass; overall size
1,000 x 2,100mm high

1 Nr

K40 DEMOUNTABLE SUSPENDED CEILINGS


PVC tongued and grooved strip ceiling 10mm thick,
incorporating U-clips; fixing into to hardwood framing
(measured separately)
Linings
B

Ceilings, plain pattern


Exposed grid suspension system, 600 x 600 x 15mm
mineral fibre panels, semi recessed regular edge profile,
predecorated finish, white; laying in position in galvanized
steel grid on galvanized adjustable wire hangers; including
perimeter trims

57 m2

Page N0
2/14

Ceilings; fixing hangers at 1200mm centres both ways to


timber
C

Depth of suspension 150 - 500mm

547 m2

Carried to Collection

COLLECTION
Page Nr. 2/13
Page Nr. 2/14

K LININGS / SHEATING / DRY PARTITIONING


To Summary of Bill Nr. 2

JOB N0

ITEM
OFFICE BUILDING

L WINDOWS / DOORS /
STAIRS

L WINDOWS/DOORS/STAIRS
L10 - WINDOWS / ROOFLIGHTS / SCREENS / LOUVRES

Windows in Extruded Aluminium profile and glass


Aluminium windows and window frames; white colour
profiles factory glazed with 6mm tinted sheet glass; fixing in
position; including fixtures and subframe in galvanized steel;
standard fitting
Sliding
A

Two bays; overall size 2000 x 1500mm high

8 Nr

Two bays; overall size 2000 x 750mm high

3 Nr

One bay; overall size 900 x 1200mm high

1 Nr

Ditto; overall size 900 x 750mm high

16 Nr

Page N0
2/15

Rooflights in Glass and and stainless steel


Tempered glass 20mm thick with stainless steel steel
anchors, neoprene pads and gaskets
E

6200 x 2,275mm wide hoisted 3,400mm above ground


level

1 Nr

L20 - DOORS / SHUTTERS / HATCHES


Door frames in hardwood, Doors in Solid Wood
Wrot hardwood in 'Odum' species or other approved equal;
treated with preservative
Flush doors comprising hardwood skeleton framing with
6mm thick internal quality veneered plywood (selected for
clear varnish measured separately) covering on both sides
and hardwood lipping on all edges
Doors
F

700 x 2050 x 45mm

24 Nr

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

L Windows / Doors /
Stairs
(Cont'd)

L20 - Doors / Shutters / Hatches (Cont'd)


Door frames in hardwood, Doors in Solid Wood
Wrot hardwood in 'Odum' species or other approved equal;
treated with preservative
Panelled doors 100mm wide stiles and top rail; 150mm wide
intermediate rail; 200mm wide bottom rail; all open rebated
and filled with 20mm thick hardwood panel
Doors
A

825 x 2050 x 45mm

Wrot hardwood in 'Odum' species or other approved equal;


treated with preservative
Door frames and door linings

16 Nr

Page N0
2/16

45 x 145mm; Jambs

168 m

45 x 145mm; Heads

22 m

Sawn hardwood: treated with preservative


Grounds
D

25 x 50mm; fixing to masonry

190 m

Doorset in Pressed metal


Factory doorsets finished in spray oil paint finish; external
fire rated purpose metal frames 1.6mm double rebated,
standard extension pieces; butt hinges; mortice locks;
reference ( from Superlock, Primordial Ltd or other equal)
E

1000 x 2032mm height unit, to 150mm thick wall, solid


flush panel door by shopfitter, 785 x 1982mm

1 Nr

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

L Windows / Doors /
Stairs
(Cont'd)

L30 - STAIRS / WALKWAYS / BALUSTRADES


Stainless Steel
Stainless steel balustrade 1000mm high overall; consisting
of 60mm diameter pipe top rail; 3 Nr 25mm diameter pipe
intermediate rails; 50mm diameter standards at 750mm
centres; all welded together, ends plugged and screwed to
concrete
A

Isolated balustrades; raking; 1000mm high

Isolated balustrades; level; ditto

Carried to Collection

28 m
3m

Page N0
2/17

COLLECTION
Page Nr. 2/15
Page Nr. 2/16
Page Nr. 2/17

L WINDOWS/DOORS/STAIRS
To Summary of Bill Nr. 2

ITEM

JOB N0
OFFICE BUILDING

M SURFACE FINISHES

M SURFACE FINISHES
M10 - CEMENT : SAND / CONCRETE SCREEDS /
TOPPINGS
Cement and sand (1:3); one coat; floated
Floors
A

75mm thick; level and to falls 15 from horizontal

732 m2

Treads
B

30mm thick; 300mm width

45 m

Risers
C

12mm thick; 170mm high

50 m

Page N0
2/18

Strings
D

12mm thick; 350mm wide; raking

28 m

Cement and sand (1:3) mixed with approved water-proof


additive; one coat; trowelled; external
Roofs
E

50mm thick; level and to falls 15 from horizontal

21 m2

M20 - PLASTERED / RENDERED / ROUGHCAST


COATINGS
Cement and sand (1:4); one coat; trowelled
Walls
F

20mm thick render; width > 300mm; to blockwork or


concrete

783 m2

Ditto; width 300mm; do

283 m

Ceiling
H

20mm thick render; width > 300mm; to blockwork or


concrete; staircase area

42 m2

Isolated column
J

20mm thick render; width > 300mm; on concrete

276 m2

Carried to Collection
ITEM

JOB N0
OFFICE BUILDING

M Surface Finishes
(Cont'd)

M20 - Plastered / Rendered / Roughcast Coatings (Cont'd)


Cement and sand (1:4); one coat; floated
Walls
A

13mm thick render; width > 300mm; to blockwork or


concrete

357 m2

Ditto; width 300mm; do

165 m

M40 - STONE / CONCRETE / QUARRY / CERAMIC TILING


/ MOSAIC

Page N0
2/19

Ceramic tiles 300 x 550 x 6mm thick, approved colour, two


symmetrical joints layout, bedding in an approved adhesive;
pointing with matching colour tile grout
Walls
C

Plain; width > 300mm

357 m2

Ditto; width 300mm; do

165 m

Upolished porcelain tiles 450 x 450 x 10mm thick, approved


colour, two symmetrical joints layout, bedding in an
approved adhesive; pointing with matching colour tile grout

Floors
E

Level or to falls 15 from horizontal; to concrete; plain

42 m2

Polished porcelain tiles 600 x 600 x 10mm thick, approved


colour, two symmetrical joints layout, bedding in an
approved adhesive; pointing with matching colour tile grout
Floors
F

Level or to falls 15 from horizontal; to concrete; plain

690 m2

Skirting
G

296 m

100mm high
Treads

300mm width with non-slip tile strip nosing

45 m

Risers
J

50 m

150mm high

Carried to Collection
ITEM

JOB N0
OFFICE BUILDING

M Surface Finishes
(Cont'd)

M40 - Stone / Concrete / Quarry / Ceramic Tiling / Mosaic


(Cont'd)
Extra over
Accessories
A

Aluminium round cover strips to edges of tiles

M60 - PAINTING / CLEAR FINISHING


Prepare and apply two coats of 'Coral' base skimming Putty
on cement render

283 m

Page N0
2/20

General surfaces
B

Girth > 300mm

1,319 m2

Prepare and apply two undercoats, one finishing coat of


''Coralplus" Acrylic Emulsion Paint on cement render
General surfaces
C

Walls; Girth > 300mm

Ceilings; Girth > 300mm

42 m2

Column; Girth > 300mm

276 m2

1,001 m2

Prepare and apply two undercoats, one finishing coat of


''Coral wallguard" Acrylic Emulsion Paint on cement render

General surfaces
F

Walls; Girth > 300mm

302 m2

Prepare and apply one coat of Aluminium primer on


woodwork
General surfaces
G

Girth 300mm; application on site prior to fixing

29 m2

Prepare and apply two coats of "Coral'' Nitrocellulose sealer


and three coats of "Coral" Coramar Polyurethane Satin
Marine varnish on woodwork:
General surfaces
H

Girth > 300mm

139 m2

Girth 300mm

48 m2

Carried to Collection
ITEM

JOB N0
OFFICE BUILDING

M Surface Finishes
(Cont'd)

M60 - Painting / Clear Finishing (Cont'd)


Prepare and apply two coats of enamel gloss oil paint
General surfaces of structural metalwork
A

Girth > 300mm

150 m2

Carried to Collection

Page N0
2/21

COLLECTION
Page Nr. 2/18
Page Nr. 2/19
Page Nr. 2/20
Page Nr. 2/21
M SURFACE FINISHES
To Summary of Bill Nr. 2

ITEM

JOB N0
OFFICE BUILDING

N FURNITURE / EQUIPMENT
N10 GENERAL FIXTURES / FURNISHINGS /
EQUIPMENT
Mirrors; B.S.952, clear float, SG, silvered & protected
with copper backing, undercoat paint and stoved
enamel

N FURNITURE /
EQUIPMENT

Page N0
2/22

6mm thick; fixing to masonry through vulnerable materials,


with brass screws, chromium plated domical covers, rubber
sleeves and washers
A

450 x 600mm; holes - 4; edges bevelled

11 Nr

PORTABLE FIRE EXTINGUISHERS


Supply and Install the following Fixturesportable fire
extinguishers; make Macron or approved equal
B

Multi-purpose dry chemical fire extinguisher


Capacity: 9kg

4 Nr

C02 fire extinguisher


Capacity: 5kg

4 Nr

N11 DOMESTIC KITCHEN FITTINGS


Exposed faces, shutters, partitions and shelves: 20 mm
thick plywood boards moisture resistant, with 3 mm veneer
lips, including drawers, ironmongery, accessories
Kitchen complete including:
D

Base units, 4350mm length x 600mm wide x 900 mm


high overall

1 Nr

Ditto, 2625 x 600 mm wide x 900 mm high overall

1 Nr

25mm thick Corian worktops ; combining integral cove and


waterfall backsplash,
F

4675 x 650mm; fixing with screws

1 Nr

Ditto, 2625 x 650 mm

1 Nr

Extra over
H

cutting opening for double bowl inset sink 510 x 405mm

1 Nr

Carried to Collection
ITEM

JOB N0
OFFICE BUILDING

N11 Domestic Kitchen Fittings (Cont'd)


Supply and Install the following Fixtures; Make; Twyfords,
Armitage Shanks or other approved equivalent

N Furniture / Equipment
(Cont'd)

Page N0
2/23

Double bowl, single drain stainless steel cabinet sink unit


complete with 13mm dia. Mixer flip-up tap unit. 40mm dia.
waste outlet with chain and plug; 40mm dia. bottle trap. All
fittings shall be chromium plated.
A

600 x 1300mm; fixing to masonry; sealing at back with


mastic sealant

1 Nr

N13 SANITARY APPLIANCES / FITTINGS


Supply and Install the following Fixtures; Make; Twyfords,
Armitage Shanks or other approved equivalent
Wash basins; white vitreous china to BS.3402; 32mm
chromium plated slotted waste, chain, stay and plug to
BS.3380; 32mm stainless steel bottle trap; painted
cantilever brackets; 13mm chrome plated Mixer flip-up taps
to BS.1010
B

560 x 415mm; fixing brackets to masonry with screws;


sealing at back with mastic sealant

11 Nr

Close coupled WC. suite, horizontal outlet; white vitreous


china pan; 9 litre wall hung white vitreous cistern to
BS.3402; plastic float operated valve with S or P trap outlet
connector; plastics seat and cover with stainless steel
hinges
C

fixing pan and cistern to masonry with screws; bedding


pan in mastic; jointing pan to soil pipe with outlet
connector

11 Nr

Automatic hand drier


D

White thermoplastic outer case with class II double


insulating; Compact high performance fan with noise
level not exceeding 68dBA at 1.5m. `No Touch; Safety
Cut-out and safety time.; Rating: 1.4 Kw operation'

11 Nr

Carried to Collection

ITEM

JOB N0
OFFICE BUILDING

N13 Sanitary Appliances / Fittings (Cont'd)

N Furniture / Equipment
(Cont'd)

Page N0
2/24

Accessories; Twyfords, Armitage Shanks or approved


equal,
Liquid soap dispenser as BRIGHTWELL. Capacity: 2 Lts
A

fixing to masonry with screws

11 Nr

Toilet roll holder; stainless steel


B

150 x 76mm; fixing to masonry with screws

11 Nr

Towel rail; stainless steel


C

650mm long; fixing to masonry with screws

11 Nr

Carried to Collection

COLLECTION
Page Nr. 2/22
Page Nr. 2/23
Page Nr. 2/24
N FURNITURE / EQUIPMENT
To Summary of Bill Nr. 2

ITEM

JOB N0
OFFICE BUILDING

P BUILDING FABRIC
SUNDRIES

Page N0
2/25

P BUILDING FABRIC SUNDRIES


P20 - UNFRAMED ISOLATED TRIMS / SKIRTINGS /
SUNDRY ITEMS
Hardwood; treated with preservative wrought
Architraves
A

15 x 75mm fixing with screws

380 m

Stops
B

15 x 50mm fixing with screws

190 m

P21 - IRONMONGERY
Supply and fix with matching screws to hardwood and the
like; 'Ingersoll-Rand' or other approved equal
C

100mm heavy duty stainless steel double ball bearing


butt hinges with return action; 1 Pairs

40 Nr

Anodised Aluminium oval plate mortice Anodised


Aluminium oval plate mortice under master key with lever
handle furniture; 75mm

21 Nr

Anodised aluminium oval plate WC indicator lock

19 Nr

Satin Stainless Steel Floor Mounted Rubber Door Stop

Briton Door closer c/w matching arm

40 Nr
4 Nr

P32 - HOLES, CHASES ETC FOR SERVICES


BUILDERS WORK IN CONNECTION WITH PIPED
SUPPLY SYSTEMS
Cut chase in sandcrete blockwork for pipe; make good all
work disturbed
147 m

12mm diameter pipe

20mm ditto

48 m

25mm ditto

45 m

Carried to Collection

ITEM

JOB N0
OFFICE BUILDING

P Building Fabric
Sundries
(Cont'd)

Page N0
2/26

P32 - Holes, Chases Etc For Services (Cont'd)

Cut hole in sandcrete blockwork for pipe; make good all


work disturbed
A

15mm diameter pipe

56 Nr

25mm diameter pipe

48 Nr

32mm ditto

22 Nr

75mm ditto

32 Nr

100mm ditto

16 Nr

BUILDERS WORK IN CONNECTION WITH ELECTRICAL


POWER SYSTEMS
Cut away after the electricial in conduit installations;
including cutting or leaving holes, notches, sinkings and
chases in the structure and its covering; make good all work
disturbed
F

Lighting points and associated switch points of any size


and type

204 Nr
95 Nr

Socket outlet points; ditto

Fitting outlet point of any size, type and kind

8 Nr

Equipment point and control gear poit; ditto

1 Nr

Carried to Collection

COLLECTION
Page Nr. 2/25
Page Nr. 2/26

P. BUILDING FABRIC SUNDRIES


To Summary of Bill Nr. 2

ITEM

JOB N0
OFFICE BUILDING

R DISPOSAL SYSTEMS

Page N0
2/27

R DISPOSAL SYSTEMS
R10 RAINWATER PIPEWORK /GUTTERS
UPVC square section pipes and fittings, BS 4514; solvent
welded joints; ipework and supports self coloured white
Pipes; staright; supports at average 1000mm centres
A

80 x 80mm in standard holderbats fixing to blockwork


with galvanised screws

101 m

Extra; shoes

6 Nr

Ditto; bends

12 Nr

Roof outlets as Fulbora or other approved equal


D

outlet spigot; solvent welded joint to plastic

6 Nr

UPVC box gutters and fittings; push fit connector joints;


gutterwork and supports self coloured white
Gutters; straight; supports at average 1000mm centres
E

150 x 100mm; in standard fascia brackets fixing to


timber with galvanised screws

59 m
4 Nr

Extra; angles

R11 FOUL DRAINAGE ABOVE GROUND


Supply and install the following class 'B' upvc pipes and
fittings with solvent cement.
Pipes; straight
G

100mm diameter; fixed to concrete with aluminium clips


at 1.10m centres; in ducts

38 m

100mm diameter; in concrete or blockwork

18 m

50mm diameter; fixed to concrete with aluminium clips at


1.10m centres; in ducts

59 m

50mm diameter; in concrete or blockwork

22 m

32mm diameter; ditto

15 m

Carried to Collection

ITEM

JOB N0
P Building Fabric

Page N0

OFFICE BUILDING

Sundries
(Cont'd)

2/28

R11 Foul Drainage Above Ground


Supply and install the following class 'B' upvc pipes and
fittings with solvent cement.
Items extra over
A

fittings, pipe 65mm diameter; two ends

40 Nr

fittings, pipe 65mm diameter; three ends

15 Nr

fittings, pipe 65mm diameter; floor drains

20 Nr

fittings, pipe > 65mm diameter; three ends

12 Nr

fittings, pipe > 65mm diameter; 900 bend, two ends

32 Nr

fittings, pipe > 65mm diameter; swept tee, three ends

3 Nr

Carried to Collection

COLLECTION
Page Nr. 2/27
Page Nr. 2/28

R DISPOSAL SYSTEMS
To Summary of Bill Nr. 2

ITEM

JOB N0

Page N0

OFFICE BUILDING

S PIPED SUPPLY SYSTEMS

2/29

S PIPED SUPPLY SYSTEMS


S10 COLD WATER
Supply and install the following class 'C' upvc pipes and
fittings with solvent cement.
Pipes; straight
A

40mm diameter; in concrete or blockwork

36 m

32mm diameter; ditto

98 m

25mm diameter; ditto

44 m

20mm diameter; ditto

48 m

15mm diameter; ditto

47 m

Items extra over


F

fittings, pipe 65mm diameter; two ends

52 Nr

fittings, pipe 65mm diameter; three ends

17 Nr

Flexible connector

25 Nr

Pipework ancillaries
J

Stop valves; nominal size 40mm; fixed to pvc pipe in


concrete/blockwork

3 Nr

Stop valves; nominal size 32mm; fixed to pvc pipe in


concrete/blockwork

6 Nr

Stop valves; nominal size 25mm; fixed to pvc pipe in


concrete/blockwork

7 Nr

Non return valve; nominal size 40mm; fixed to pvc pipe


in concrete/blockwork

1 Nr

Stop valves; nominal size 20mm; fixed to pvc pipe in


concrete/blockwork

9 Nr

Check valves; nominal size 15mm; fixed to pvc pipe in


concrete/blockwork

26 Nr

Non return valve; nominal size 15mm; fixed to pvc pipe


in concrete/blockwork

26 Nr

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

S Piped Supply System


(Cont'd)

Page N0
2/30

S10 Cold Water (Cont'd)


Supply and install the following:Equipment;
A

Cold water storage cistern; plastic


Nominal Capacity : 6,000 Litres with the ff: accessories
i) 25mm dia. Inlet connector with ballvalve
iii) 25mm dia. Outlet connector
iii) 50mm dia. drain / overflow connectors

1 Nr

Cold water storage cistern; plastic


Nominal Capacity : 6,000 Litres with the ff: accessories
i) 25mm dia. Inlet connector with ballvalve
iii) 25mm dia. Outlet connector
iii) 50mm dia. drain / overflow connectors

2 Nr

Automatic Cold Water Booster Pumpset complete


with float switch as DAB 2Jet 251M or approved equal
Discharge : 1.0 l/s; Head : 40m

2 Nr

S11 HOT WATER


Supply and install the following Copper upvc pipes and
fittings with soldered and screwed joints.
Pipes; straight
D

15mm diameter; fixed to concrete with clips at 1.10m


centres; in ducts

13 m

Items extra over


E

fittings, pipe 65mm diameter; two ends

3 Nr

Flexible connector

1 Nr

Pipework ancillaries
G

Stop valves; nominal size 15mm; fixed to copper pipe in


concrete/blockwork

Storage type, unvented under-cabinet water heater


as ARISTON or approved equal
Storage Capacity: 15 Litres
Heater Capacity : 1.0KW

Carried to Collection

1 Nr

1 Nr

JOB N0

ITEM
OFFICE BUILDING

S Piped Supply System


(Cont'd)

S60 FIRE HOSE REELS


Supply and install the following galvanized
pipes and fittings jointed with threaded fiitings
A

50mm dia. pipe

20mm ditto

6m

50mm x 90O elbow

5 Nr

50mm equal tee

4 Nr

50 x 50 x 20mm reducing tee

4 Nr

20mm x 90O elbow

4 Nr

50mm gate isolating valve

1 Nr

20mm dia globe stop valve

4 Nr

50mm screwed end cap

1 Nr

50mm dia. Automatic Air Vent

1 Nr

Swinging fire hosereels as MACRON


with automatically operated valve to the ff:Nozzle type - Jet
Nozzle size - 20mm
Nose length - 30m
Finish
- Red

4 Nr

Fully automatic packaged fire hosereel


pump unit as DAB 1K 70/300T or approved equal
Capacity:
2,3 litres/sec.
Closed Valve Head: 60m
Pump and associated controls shall
comply with BS 5306.

1 Nr

18 m

Carried to Collection

COLLECTION
Page Nr. 2/29
Page Nr. 2/30
Page Nr. 2/31

Page N0
2/31

S PIPED SUPPLY SYSTEMS


To Summary of Bill Nr. 2

ITEM

JOB N0
OFFICE BUILDING

U VENTILATION / AIR
CONDITIONING SYSTEMS

U VENTILATION / AIR CONDITIONING SYSTEMS


U10 GENERAL VENTILATION
Wall Extract Fan with external louvre and back draught
shutters
A

Capacity : 50cfm
Power : Fractional hp SPN 50Hz 240V

15 Nr

U60 AIR CONDITIONING UNITS

Supply and Install the following Air-conditioning epuipment;


Make; White Western House or approved equal
Wall split air-conditioning units complete with pre-charged
and refrigerant
B

Split system comprising of single circuit air-cooled


condensing (outdoor) unit & high wall mounted
fan coil (indoor) unit
Cooling Capacity: 7.0KW (2.5HP) (24,000BTU)
Electrical Load: 2.5KW
Condensing unit: on brackets

19 Nr

Ditto
Capacity 6.1kw (20800Btu/hr) each
Condensing unit: on brackets

3 Nr

Ditto
Capacity 4.22kw (14350Btu/hr) each
Condensing unit: on brackets

2 Nr

REFRIGERANT PIPING
Supply and install the following pre-charged and insulated
refrigerant copper piping with aero equip connectors,
complete with formed polyurethane pipe insulation as
Armaflex or approved equal
E

Suction Line Size: 16mm OD


Liquid Line Size : 6mm OD
Length
: 21 m

1 Nr

Ditto
Length

3 Nr

: 17 m

Page N0
2/32

Ditto
Length

: 11 m

2 Nr

Carried to Collection
JOB N0

ITEM
OFFICE BUILDING

U Ventilation / Air
Conditioning Systems
(Cont'd)

U60 Air Conditioning Units (Cont'd)


Refrigerant Piping (Cont'd)
Supply and install the following pre-charged and insulated
refrigerant as before described
A

Suction Line Size: 16mm OD


Liquid Line Size : 6mm OD
Length
: 10 m

3 Nr

Ditto
Length

: 6m

7 Nr

Ditto
Length

: 4m

8 Nr

CONDENSATE DRAINAGE
Supply and install the following class 'B' upvc pipes
and fittings
C

20mm dia. upvc pipe

54 Nr

15mm dia. Ditto

72 Nr

20mm dia. x 90O elbow

15mm dia. ditto

48 Nr

20mm x 20mm x 15mm reducing tee

22 Nr

20mm dia. running trap with 50mm water seal

24 Nr

3 Nr

ELECTRICAL WIRING
Supply and install the following:
J

Electrical wiring from building Isolator to condensing unit;


Cable Size: 3 x 4.0mm2

368 m

Packaged electrical cabling from condensing unit to fan


coil units; Cable size: 3 x 2.5mm2

246 m

Page N0
2/33

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

U Ventilation / Air
Conditioning Systems
(Cont'd)

Page N0
2/34

COLLECTION
Page Nr. 2/32
Page Nr. 2/33

U VENTILATION / AIR CONDITIONING SYSTEMS


To Summary of Bill Nr. 2

GH

ITEM

JOB N0
OFFICE BUILDING

V ELECTRICAL SUPPLY /
POWER LIGHTING
SYSTEMS

V ELECTRICAL SUPPLY / POWER LIGHTING SYSTEMS

V20 LV DISTRIBUTION
LV Cables and Wiring
Polyvinylchloride material jointed in solvent cement in
A

50mm diameter rigid; straight; in concrete floor


or block wall
Extra over the conduit in which they occur
150mm x 150mm junction boxes

71 m

5 Nr

"Pilca" type swa/pvc insulated copper in


C

Cables
4C - 35mm2

75 m

4C - 16mm2

88 m

1C - 25mm2

Connections
35mm2 cable lug

16 Nr

25mm2 cable lug

6 Nr

35mm2 cable gland

4 Nr

25mm2 cable gland

2 Nr

314

LV Switchgear and Distribution boards

Supply and install low voltage switchboards and switchgear


as LUCY or approved equal in compliance with BS 2817 or
other internationally approved standards as follows:
K
L

6 way TPN fitted with 250A TPN MCCB ''LU Pannel


board"

1 Nr

200A TPN switch with H.R.C. Fuse

1 Nr

Page N0
2/35

12 way TPN fitted with 100A TP integral main switch


complete with miniature circuit breakers.

4 Nr

200A TPN cut-out unit

1 Nr

63A, TP MCCB, c/w Enclosure (UPS Incomer)

4 Nr

200A Automatic Change over Switch

1 Nr

Carried to Collection
JOB N0

ITEM
OFFICE BUILDING

V Electrical Supply /
Power Lighting Systems
(Cont'd)

V21 GENERAL LIGHTING


LV Cables and Wiring/
Cable and conduit in final circuits
Polyvinylchloride material jointed in solvent cement in
A
20mm diameter rigid; straight; in concrete floor or block wall
1,720 m
Extra over the conduit in which they occur
B

20mm Pvc Circular box

75mm x 75mm Galvanized conduit box

204 Nr
42 Nr

"Kablemetal" or other approved equal insulated copper


Cables
D

1.5mm2 pvc insulated cable as live, neutral and earth run


separately in rigid pvc conduit(measured separately)

6,188 m

Luminaires and Lamps


Accessories for Electrical Services
Lamp as 'Tec Mar' or approved equal
E

2 x 18w Recessed mounted compact fluorescent


downlighter with decorative Diffuser

24 Nr

2 x 18w Ceiling mounted compact fluorescent c/w Opal


Diffuser

44 Nr

4 x 14w, T5 600mm x 600mm recessed fluorescent light


fitting with Aluminium Louvre

95 Nr

1 x 13w Recessed compact fluorescent Spotlight Fitting

14 Nr

2 x 18w Wall Bracket compact fluorescent c/w Opal


Diffuser

8 Nr

2 x 8w 'TL'D fluorescent self-contained, non-maintained


3-hour prismatic diffuser emergency fittings, c/w "EXIT"
Pictogram

4 Nr

F
G

Page N0
2/36

Accessories for Electrical Services


High quality "MK Logic" make, wall flush
Accessories; 6A switches
L

one way, one gang

26 Nr

one way, two gang

12 Nr

one way, three gang

4 Nr
-

Carried to Collection
JOB N0

ITEM
OFFICE BUILDING

V Electrical Supply /
Power Lighting Systems
(Cont'd)

V22 GENERAL LV POWER


HV/ LV Cables and Wiring/
Cable and conduit in final circuits
Polyvinylchloride material jointed in solvent cement in
A
20mm diameter rigid; straight; in concrete floor or block wall
1,720 m
Extra over the conduit in which they occur
B

75mm x 75mm Galvanized conduit box

42 Nr

"Kablemetal" or other approved equal insulated copper


Cables
C

2.5mm2 pvc insulated cable as live, neutral and earth run


separately in rigid pvc conduit(measured separately)

3,140 m

4mm2 ditto

1,231 m

6mm2 ditto

43 m

Accessories for Electrical Services


High quality "MK" made, wall flush
F

Accessories; switch socket outlet


13A; 2 gang; 2 pole

28 Nr

Ditto; floor mounted

41 Nr

20A, with red light indicator for Air Condition

24 Nr

20A, with red light indicator for Water Heater

1 Nr

45A, Cooker control unit switch outlet

1 Nr

K
Test the above installation according to IEE wiring regulation

item

Page N0
2/37

Carried to Collection

COLLECTION
Page Nr. 2/35
Page Nr. 2/36
Page Nr. 2/37
V ELECTRICAL SUPPLY / POWER LIGHTING SYSTEMS
-

To Summary of Bill Nr. 2


JOB N0

ITEM
OFFICE BUILDING

W COMMUNICATION /
SECURITY / CONTROL
SYSTEMS

W COMMUNICATION / SECURITY / CONTROL SYSTEMS

W10 TELECOMMUNICATIONS
Supply and install internal and external Telephone
Communication equipment and accessories as follows:
A

20mm Pvc pipe

366 m

20mm Pvc Circular box

40 Nr

75mm x 75mm Galvanized conduit box

60 Nr

50-pair wall mounted Telephone BT


(Terminal Block)

2 Nr

24 Port Patch Panel

1 Nr

Category 5e Data Cable

2 Gang RJ11 Telephone socket outlet

300mm x 150mm Pvc Junction Box with cover

471 m
21 Nr
4 Nr

W20 RADIO / TV / CCTV


CCTV INSTALLATIONS
Supply and install the following CCTV system
J

24 Channel Stream DVR

1 Nr

Low lux Day & Night Camera

8 Nr

Dome Camera

4 Nr

Page N0
2/38

26'' Monitor (LED)

1 Nr

Power supply units

1 Nr

Coaxial & Power supply cable

568 m

20mm PVC pipe

455 m

4U Wall mounted cabinet

Testing, Commissioning & Programming

1 Nr

GH

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

W Communivation /
Security / Control Systems
(Cont'd)

W20 Radio / TV / CCTV (Cont'd)


LOCAL TV RECEPTION SYSTEM
A

UHG/VHFFM Broad Band Antennae complete


with fixing brackets and other accessories

1 Nr

Terrestial signal boosting amplifier with integral power


supply unit complete with lightning protection system

1 Nr

Satellite Coaxial Cable (RG6)

205 m

TV Socket Outlet

20mm Diameter Pvc pipe

90 m

20mm Diameter Pvc Circular box

15 Nr

75mm x 75mm Galvanized knockout box

8 Nr

8 Nr

W30 DATA TRANSMISSION


Supply and install internal and external Data equipment and
accessories as follows:
J

20mm Pvc pipe

298 m

20mm Pvc Circular box

40 Nr

75mm x 75mm Galvanized knockout box

55 Nr

27U Rack Cabinet

1 Nr

24 Port Patch Panel

3 Nr

2 Gang RJ45 Module and face plate complete

10 Nr

Page N0
2/39

Category 6e Data Cable

300mm x 150mm Pvc Junction Box with cover

442 m
2 Nr

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

W Communivation /
Security / Control Systems
(Cont'd)

W50 FIRE DETECTION AND ALARM


Supply and install automatic Fire Detection and Signalling
materials and equipment as manufactured by or approved
equivalent as follows:
A

6-Zone conventional control panel complete with


integral battery, charger and other requisite
accessories.
Optical Smoke Sensor complete with
mounting base

1 Nr

30 Nr

Ditto but Heat Detector

4 Nr

Manual call point (Ref: Gent Cat. No. 14112-08)

4 Nr

2-way Electronic sounder (Ref: Gent Cat. No. 34202)

4 Nr

20mm diameter pvc pipe

20mm pvc circular box

75mm x 75mm knockout box

3-core 0.75mm2 pvc fire resistant cable

W51 EARTHING AND BONDING


"Pilca" type swa/pvc (green/ yellow) insulated
copper in
Cable

459 m
34 Nr
4 Nr
289 m

Page N0
2/40

35mm2, bonded to the main switch or maindistribution


board and an earth electrode (distribution board and
electrode measured separately)

38 m

16mm diameter, 1500mm long copper bonded earth


electrode c/w clamps

8 Nr

6mm x 40mm x 300mm Earth Bar mounted on Insulators


on wall.

1 Nr

Earth Inspection chamber, c/w concrete cover.

1 Nr

Carried to Collection

JOB N0

ITEM
OFFICE BUILDING

W Communivation /
Security / Control Systems
(Cont'd)

W52 LIGHTNING PROTECTION

Supply and install a lightning protection system comprising


equipment and materials manufactured by Messrs A. N.
WALLIS or any other approved manufacturer as follows:
16mm thread diameter copper multi-point Air
Terminal (Ref: A.N. WALLIS Cat No. MPC 16)

2 Nr

2000m Long 16mm thread diameter copper


elevation rod. (Ref: A.N. WALLIS Cat No. AE170)

2 Nr

25mm x 3mm Gunmetal square tape clamp

8 Nr

25mm x 3mm Copper tape down conductor


(Ref: A.N. WALLIS Cat No. TL253)

100 m

Naval Brass metallic DC tape clip complete


with clip and plug

100 Nr

900mm x 900mm High conductivity annealed


copper latticed mat as earth termination
(Ref: A.N. WALLIS Cat No. EML903)

2 Nr

16mm diameter, 1200mm long copper bonded


earth electrode cad welded to four corners of
earth mat
(Ref: A.N. WALLIS Cat No. EBR12)

8 Nr

25mm x 3mm Gunmetal screw down test


clam (Ref: A.N. WALLIS Cat No. JSG 253)

2 Nr

Page N0
2/41

Carried to Collection

COLLECTION
Page Nr. 2/37
Page Nr. 2/38
Page Nr. 2/39
Page Nr. 2/41

W COMMUNICATION / SECURITY / CONTROL SYSTEMS


To Summary of Bill Nr. 2

ITEM

JOB N0
OFFICE BUILDING

SUMMARY

Page N0
2/42

PAGE BILL Nr. 2 - SUMMARY


NR
2/2

C EXISTING SITE / BUILDINGS / SERVICES

2/3

GROUND WORK

2/6

E. IN-SITU CONCRETE / LARGE PRECAST CONCRETE

2/7

F. MASONRY

2/10 H CLADDING / COVERING

2/12 J WATERPROOFING

2/13 K LININGS / SHEATING / DRY PARTITIONING

2/17 L WINDOWS/DOORS/STAIRS

2/19 M. SURFACES FINISHES

2/24 N FURNITURE / EQUIPMENT

2/26 P BUILDING FABRIC SUNDRIES

2/28 R. DISPOSAL SYSTEMS

2/31 S PIPED SUPPLY SYSTEMS

2/34 U VENTILATION / AIR CONDITIONING SYSTEMS

2/37 V. ELECTRICAL SUPPLY / POWER LIGHTING SYSTEMS


2/41 W COMMUNICATION / SECURITY / CONTROL SYSTEMS
BILL Nr. 2 - OFFICE BUILDING
Carried to General Summary

Vous aimerez peut-être aussi