Académique Documents
Professionnel Documents
Culture Documents
Notice
The information contained in this document is subject to change without notice.
STRATUS COMPUTER, INC., MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Stratus
Computer, Inc., shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing,
performance, or use of this material.
Stratus Computer, Inc., assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Stratus
Computer, Inc.
This document is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another
language without the prior written consent of Stratus Computer, Inc.
Stratus, Continuous Processing, StrataNET, FTX, and the Stratus logo are registered trademarks of Stratus Computer, Inc.
XA, XA/R, StrataLINK, RSN, and the SQL/2000 logo are trademarks of Stratus Computer, Inc.
Manual Name: Product Release Bulletin: I101-11 Link Controller - Type A11
Part Number: R355
Revision Number: 00
Printing Date: March 1992
Stratus Computer, Inc.
55 Fairbanks Blvd.
Marlboro, Massachusetts 01752
Preface
The Product Release Bulletin: I101-11 Link Controller - Type A11 (R355) describes how to
configure and administer the I101-11 Link Controller for a StrataLINK network.
This manual is intended for system administrators.
Manual Version
This is a new manual.
Manual Organization
This manual contains one chapter.
Chapter 1 describes how to configure and administer the I101-11 Link Controller for a
StrataLINK network.
Related Manuals
Refer to the following Stratus manuals for related documentation.
iii
Preface
Monospace represents text that would appear on your terminals screen (such as
commands, subroutines, code fragments, and names of files and directories).
For example:
change_current_dir (master_disk)>system>doc
Monospace italic represents terms that are to be replaced by literal values. In the
following example, the user must replace the monospace-italic term with a literal value.
list_users -module module_name
Monospace bold represents user input in examples and figures that contain both user
input and system output (which appears in monospace). For example:
display_access_list system_default
%dev#m1>system>acl>system_default
w
*.*
iv
Preface
Preface
The following table lists several VOS functions and the keys to which they are mapped on
commonly used Stratus terminals and on an IBM PC or compatible PC that is running the
Stratus PC/Connect-2 software. (If your PC is running another type of software to connect to
a Stratus host computer, the key mappings may be different.) For information about the key
mappings for a terminal that is not listed in this table, refer to the documentation for that
terminal.
V103
ASCII
V103
EPC
IBM PC or
Compatible
PC
CANCEL
<F18>
<5> or *
<F18>
CYCLE
<F17>
<F12>
<Alt>-<C>
<4>
<F17>
<Shift>-<F17>
<Shift>-<F12>
<Alt>-<B>
<7>
<Shift>-<F17>
<F19>
<6> or -
<F19> or
<Shift>-<Help>
HELP
<Shift>-<F8>
<Shift>-<F2>
<Shift>-<F2>
<Shift>-<F8>
<Help>
INSERT
DEFAULT
<Shift>-<F11>
<Shift>-<F10>
<Shift>-<F10>
<Shift>-<F11>
<F11>
<F11>
<F10>
<F10>
<F11>
<Insert_Here>
INTERRUPT
<Shift>-<F20>
<Shift>-<Delete>
<Alt>-<I>
<1>
<Shift>-<F20>
NO PAUSE
<Shift>-<F18>
<Shift>- *
<Alt>-<P>
<8>
<Shift>-<F18>
VOS Function
CYCLE BACK
DISPLAY FORM
INSERT SAVED
V105
PC/+ 106
V105
ANSI
Numeric-keypad key
Online Documentation
Stratus provides the following types of online documentation.
Preface
For more information about StrataDOC as well as a complete list of the manuals that are
available online, contact your Stratus account representative.
Ordering Manuals
You can order manuals in the following ways.
If your system is connected to the Remote Service Network (RSN), issue the
maint_request command at the system prompt. Complete the on-screen form with
Customers in North America can call the Stratus Customer Assistance Center (CAC)
at (800) 221-6588 or (800) 828-8513, 24 hours a day, 7 days a week. All other
customers can contact their nearest Stratus sales office, CAC office, or distributor; see
the file cac_phones.doc in the directory >system>doc for CAC phone numbers
outside the U.S.
Manual orders will be forwarded to Order Administration.
If your comments are brief, type comment_on_manual, press <Enter> or <Return>, and
complete the data-entry form that appears on your screen. When you have completed
the form, press <Enter>.
If your comments are lengthy, save them in a file before you issue the command. Type
comment_on_manual followed by -form, then press <Enter> or <Return>. Enter this
manuals part number, R355, then enter the name of your comments file in the
-comments_path field. Press the key that performs the CYCLE function to change the
value of -use_form to no and then press <Enter>.
Note: If comment_on_manual does not accept the part number of this manual
(which may occur if the manual is not yet registered in the
manual_info.table file), you can use the mail request of the
maint_request command to send your comments.
Your comments (along with your name) are sent to Stratus over the RSN.
Stratus welcomes any corrections and suggestions for improving this manual.
vi
Preface
Contents
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1-1
1-3
1-3
1-3
1-3
vii
Figures
Figure 1-1. The I101-11 Link Controller Label . . . . . . . . . . . . . . . . . . . . .
Figure 1-2. The I101-10 Link Controller Label . . . . . . . . . . . . . . . . . . . . .
Figure 1-3. The I101 Link Controller Label. . . . . . . . . . . . . . . . . . . . . . .
viii
Figures
1-2
1-2
1-2
Chapter 1:
The I101-11 Link Controller - Type A11
1-
The I101-11 Link Controller - Type A11 combines the functionality of the I101-10 Link
Controller - Type A10 with universal direct current (UDC) power. (This document refers to
the I101-11 Link Controller - Type A11 as the I101-11 Link Controller, and to the I101-10
Link Controller - Type A10 as the I101-10 Link Controller.) UDC power enables the I101-11
Link Controller to operate in XA/R 8-slot, 10-slot, and 40-slot RISC-based systems. The
I101-11 Link Controller can also operate in XA400, XA600, and XA2000 systems.
The I101-11 Link Controller provides the following features:
conformance with central office (CO) and standard Stratus equipment requirements for
input-to-output power isolation
microprocessor and data-transfer capabilities that are the same as those provided by the
I101-10 Link Controller
1-1
You can distinguish between the three link controllers by looking at their labels. Figure 1-1
illustrates the label of the I101-11 Link Controller, Figure 1-2 illustrates the label of the
I101-10 Link Controller, and Figure 1-3 illustrates the label of the I101 Link Controller.
1
Link Controller
Type A11
Link Controller
Type A10
Link Controller
Type A
1-2
Link-Controller Configuration
When installed on a module running VOS Release 11.1 (or a later release), the I101-11 Link
Controller can transfer 32 bits of data on to and off the StrataBUS, regardless of the
configuration of link controllers.
If you initiate the link boot from a module that is running VOS Release 11.1 (or a later
release), all I101-11 Link Controllers in that module can transfer 32 bits of data on to
and off the StrataBUS.
If you initiate the link boot from a module that is running a release of VOS earlier than
11.1, all I101-11 Link Controllers in that module can transfer only 16 bits of data on to
and off the StrataBUS.
For complete information on performing a link boot, see the manual VOS System
Administration: Starting Up and Shutting Down a Module or System (R282).
1-3
1-4