Académique Documents
Professionnel Documents
Culture Documents
GuidetoInsuCal
VERSION3.0.0.0
PRABHJYOTSINGH(6119913)
LAKHANPAL(6079997)
MECHANICALPIPINGLAYOUT|BHELPEMNOIDA
Contents
1. About InsuCal
2. Input to the program
2.1
Design Parameters
2.1.1 Standard
2.1.2 Cold Face Temperature
2.1.3 Ambient Temperature
2.1.4 Emissivity
2.1.5 Wind Velocity
2.1.6 Insulation Type
2.1.7 Insulation Material
2.1.8 Interface Temperature
2.1.9 Cladding Details
2.2
Operating Conditions
2.2.1 Hot face Temperature
2.2.2 Pipe OD
2.2.3 Minimum Thickness
1.
About InsuCal
This is standalone application can be used to calculate thermal insulation thickness of power cycle
pipingsandgeneratingBOMforinsulationmaterials.Thethicknessdependsupondesignparametersof
insulation and the operating/design condition(s) of the pipe. The results also vary depending upon
whethertheprogramisrunforASTMC680orIS:14164methodofcalculation.
ThecurrentreleaseversionmaybeusedforextensivecalculationofASTMC680only.
2.
2.1.6 Insulation Type
Two different types of insulation can be employed piping systems viz. Single material insulation and
CompositeMaterialInsulation.Incompositetype,twodifferentmaterialswithdifferentconductivities
are used in combination to yield lesser diameter incase of high temperature as compared to that in
singletypeinsulation.Generally,materialwithlesserthermalconductivity(K)isappliedintheinnerside
of the insulation (Eg. Calcium Silicate), followed by material with slightly higher conductivity (Eg. LRB
Mattress).ThismethodismostlyemployedwhileusingIS:14164methodofcalculation.
ADropboxmenuiteminInsuCalcanbeusedtochangethetypeofinsulation.
2.1.7 Insulation Material
Various types of materials are employed for insulation in piping systems. The most commonly used
materials are Light Resign Bonded Mattress, Bonded Mineral RockWool Mattress or Calcium Silicate.
EvenCeramicFibersarealsobeingemployedforpipingwithoperatingtemperaturesabove500C.
Insulationmaterialcanbechangedalongwithitsconductivitycoefficienta&bbyselectingMaterial
Conductivity from the File menu. The default values are specified are of LRB Mattress and Calcium
Silicateforlowtemperatureandhightemperaturematerialrespectively.
Aradiobuttoncanbeusedtoselecttypeofgaugesandcorrespondingly,thelimitofdiametercanbe
set in the text box. The cladding material can be specified or selected from the dropdown list. The
different types of gauges available that can be employed can be selected from the dropdown list of
SWGgauges.
Generallythereare5differentgaugesavailablethatcanbeapplied;theseare16SWG,18SWG,20
SWG,22SWGand24SWG
3.
3.1
Individual Line
When insulation thickness of only a few lines are required or when the BOM is not required to be
generated,thenthisoptioncanbewidely.JustbyclickingtheCalculatebuttonintheIndividualline
orpresstheReturn/Enterkey,willgivethecalculatedinsulationthicknessasrequiredinadialogbox
alongwithotherinformationsuchasmattressweight,claddingweight,totalweightandcombinationof
layers.Ifanyofthedesignparametersoroperatingconditionsisinvalid,itwillpromptso.
Thewindowwillopenasshownbelow:
2.ClickBrowsetoselecttheinputfile
Theinputfilecanbea.txtora.csvfile.Theformatofinputshouldbeas:
ForSingleMaterialInsulation:
Serial Number, Line Description, Temperature (Hotface), Pipe OD, Length, No. of Bends less
than45,No.ofbendsgreaterthan45,Reducers,Elbow,Tees,Flanges,Valves,MinimumThickness.
i.e.Insinglelineofasystemhas13inputparameters.Theseinputsshouldbeincomaseparatedvalue
format.
Eg.1,MSHALFFLOW(BOILEREND),573,470,120,0,6,2,0,2,8,4,0
o
ForCompositeMaterialInsulation:
SerialNumber,LineDescription,Temperature(Hotface),PipeOD,Length,No.ofBendslessthan45,
No. of bends greater than 45, Reducers, Elbow, Tees, Flanges, Valves, Minimum Thickness of Higher
temperature material, Minimum Thickness of lower temperature material. i.e. In composite line of a
systemhas14inputparameters.Theseinputsshouldbeincomaseparatedvalueformat.
Eg.1,MSHALFFLOW(BOILEREND),573,470,120,0,6,2,0,2,8,4,0,0
If any of the parameters are missing or invalid characters are found or if the number of parameter(s)
dontmatch,anerrordialogisdisplayedalongwiththelineno.onwhichtheerrorhasoccurredandthe
loadingoffileiscancelled.
3.ClickOK
4.Specifytheoutputfilename(withoutextension)youwanttheBOMtohave.
5.ClicktheGenerateButton,whichwasinitiallydisabled.
6. If none of the design parameters or operating conditions is invalid, a dialog box will be displayed
prompting Report generated. will be flashed. The BOM under the specified output filename with
extension.docwillbegeneratedinthesamefolderastheInsuCalprogram.
Inaddition,theprogramwillalsochecktheoutputfilespecifiedalreadyexistsandaskstooverwrite,if
the user wishes to do so. It also checks if the already existing file is not open and If it is so, then the
outputfilewillNOTbegenerated.
4.
1.Userfriendlyinterface
2.Promptandeasydataentryandchoosingparameterslikeinsulationcode,insulationmattressand
claddingtypes.
3.BesidesreportgenerationandBOMgenerationformultiplesystems,insulationthicknessfor
individualarepromptedinadialogbox.
4.Sameinputfileformatin.csvor.txtfileisusedforobtainingpipedetailssoastomaintainthe
standardandmakeprogramimplementableforexistinginputfilesaswell.