Vous êtes sur la page 1sur 35

I.

PILING............................................................................................................. 15

II.

EXCAVATION ................................................................................................. 19

III.

CONCRETE WORK ........................................................................................ 21

IV.

BRICKWORK AND BLOCKWORK ................................................................ 26

V.

ROOFING ........................................................................................................ 28

VI.

STRUCTURAL STEELWORK AND METALWORK ....................................... 30

VII. WALL & FLOOR FINISHES............................................................................ 33


VIII. PLUMBING...................................................................................................... 36
IX.

PAINTING........................................................................................................ 39

X.

DRAINAGE WORK ......................................................................................... 41

XI.

ROADS AND PAVING .................................................................................... 44

XII. OTHER EXTERNAL WORKS AND SERVICES.............................................. 45

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/15
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

I.

PILING

A. EQUIPMENT
1. Piling Rigs
Provide and assemble piling equipment on site including moving it around site,
subsequent dismantling and removal on completion
a) rig to install bakau pile

Item

1,200.00

b) rig to install concrete pile up to 110t capacity

Item

6,000.00

c) rig to install steel 'H' pile (up to 132.44 kg/m type steel
'H'pile)

Item

7,300.00

d) rig to install steel sheet pile (up to 190 kg/m2 type steel
sheet pile)

Item

3,200.00

e) rig to install bored piles

Item 11,000.00

f)

Item 10,000.00

rig to install bored micropile

g) rig to install driven micropile

Item

5,000.00

B. TIMBER PILES
1. Bakau Piles
Supply and drive bakau pile
a) 75mm diameter ne 5.00m long

No

18.00

b) 75mm diameter 5.00 - 10.00m long, including mild steel


pipe sleeves

No

25.00

3.80

2. Mattress Piles
Supply and lay bakau roller
a) 75mm diameter
C. CONCRETE PILES
1. Precast Concrete Piles
Supply and drive precast concrete pile complying with SS CP 4
a) 155 x 155mm cross-section with 25-35t carrying capacity
m

30.00

b) 180 x 180mm cross-section with 35-45t carrying capacity

34.00

c) 205 x 205mm cross-section with 45-55t carrying capacity

38.60

d) 230 x 230mm cross-section with 55-65t carrying capacity

45.60

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/16
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

e) 260 x 260mm cross-section with 65-80t carrying capacity

54.00

f)

58.50

71.30

285 x 285mm cross-section with 80-95t carrying capacity

g) 305 x 305mm cross-section with 95-110t carrying


capacity
D. STEEL PILES
1. Isolated Piles

Supply and drive steel 'H' piles complying with BS 4360 Grade 43A with corrosion
protection to BS 5493 and BS CP 1021 including extension by weld jointing to BS
5135 and BS 6265
a) size 203 x 203mm x 53.57 kg/m

104.00

b) size 254 x 254mm x 62.50 kg/m

118.00

c) size 305 x 305mm x 78.87 kg/m

149.00

d) size 330 x 330mm x 108.63 kg/m

205.00

e) size 356 x 356mm x 132.44 kg/m

250.00

2. Interlocking Piles
Supply and drive temporary steel sheet pile complying with BS 4360 Grade 43A
including strutting, waling, extension by weld jointing to BS 5135 and BS 6265 and
subsequent extraction and removal
a) 400 x 125 x 13mm thick, 150 kg/m2 U-shaped section
2

b) 400 x 150 x 13.1mm thick, 146 kg/m U-shaped section


c) 400 x 170 x 15.5mm thick, 190 kg/m2 U-shaped section

m2

95.00

95.00

113.00

Supply and drive left in steel sheet pile complying with BS 4360 Grade 43A including
strutting, waling and extension by weld jointing to BS 5135 and BS 6265
d) 400 x 125 x 13.0mm thick, 150 kg/m U-shaped

m2

279.00

e) 400 x 150 x 13.1mm thick, 146 kg/m U-shaped

274.00

f)

353.00

400 x 170 x 15.5mm thick, 190 kg/m U-shaped

E. BORED PILES
1. Grade 35 Concrete Piles
Supply and install bored cast in place concrete piles including temporary steel casing
(reinforcement measured separately)
a) diameter 300mm

115.00

b) diameter 400mm

120.00

c) diameter 500mm

128.00

d) diameter 600mm

145.00

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/17
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

e) diameter 900mm

230.00

f)

diameter 1200mm

335.00

g) diameter 1500mm

460.00

Supply and install bored cast in place concrete piles (temporary steel casing and
reinforcement measured separately)
h) diameter 500mm

115.00

i)

diameter 600mm

140.00

j)

diameter 900mm

215.00

k) diameter 1200mm

300.00

l)

405.00

diameter 1500mm

2. Grade 40 Concrete Piles


Supply and install bored cast in place concrete piles including temporary steel casing
(reinforcement measured separately)
a) diameter 300mm

120.00

b) diameter 400mm

125.00

c) diameter 500mm

130.00

d) diameter 600mm

150.00

e) diameter 900mm

235.00

f)

diameter 1200mm

350.00

g) diameter 1500mm

470.00

Supply and install bored cast in place concrete piles (temporary steel casing and
reinforcement measured separately)
h) diameter 500mm

115.00

i)

diameter 600mm

140.00

j)

diameter 900mm

215.00

k) diameter 1200mm

305.00

l)

410.00

kg

2.10

207.00

diameter 1500mm

3. Steel Casing
a) Supply and drive steel casing to be left in for bored piles
F. MICROPILES
1. Bored Micropiles
Supply and install micropiles
a) 150mm diameter

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/18
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

b) 200mm diameter

230.00

c) 250mm diameter

288.00

Cutting of pile to the required level including welding of the bearing plate
d) generally

No

189.00

2. Driven Micropiles
Supply and drive steel micropiles complete with cement grouting to centre void
a) 114mm diameter (with working capacity of 20 ton each)

69.00

Cutting of pile to the required level including welding of the bearing plate
b) Generally

No

70.00

G. SUNDRIES
1. Pile Tests
Test loading of piles with the Kentledge reaction system including casting and
subsequent removal of temporary pile cap
a) generally

46.00

a) 100 x 100mm cross-section

No

46.00

b) 125 x 125mm cross-section

No

54.00

c) 150 x 150mm cross-section

No

62.00

d) 155 x 155mm cross-section

No

65.00

e) 175 x 175mm cross-section

No

70.00

f)

180 x 180mm cross-section

No

73.00

g) 205 x 205mm cross-section

No

78.00

h) 230 x 230mm cross-section

No

86.00

i)

260 x 260mm cross-section

No

91.00

j)

285 x 285mm cross-section

No

95.00

k) 305 x 305mm cross-section

No

103.00

No

79.00

2. Pile Shoes
Supply and fix chilled hardened cast iron pointed coaxial pile shoe

Supply and install mild steel pile shoe


l)

114mm diameter

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/19
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

II.

EXCAVATION

A. SITE CLEARANCE
1. Clear Site Vegetation
Clear bushes, shrubs, undergrowth, saplings, grass, rubbish and small trees not
exceeding 600mm girth including grubbing up roots, filling voids and disposal of
materials off site
a) generally

m2

1.40

2. Remove Trees
Cut tree including grubbing up roots, filling voids and disposal of materials off site
a) 600 - 1000mm girth

No

206.00

b) 1000 - 1500mm girth

No

433.00

c) 1500 - 2000mm girth

No

721.00

d) 2000 - 2500mm girth

No

863.00

a) average 100mm deep

m2

0.85

b) average 200mm deep

m2

1.30

c) average 300mm deep

2.00

7.50

3. Oversite Excavation
Excavate over site, commencing from ground level, to reduce level

d) 300 - 1000mm deep


B. GENERAL EXCAVATION
1. Pit/Trench Excavation
Excavate to form trench, commencing from reduced level
a) ne 1.00m deep and cross sectional area ne 0.50m2

5.50

b) ne 2.00m deep

m3

13.00

c) 2.00 - 4.00m deep

m3

21.00

d) 4.00 - 5.00m deep

29.60

m3

13.30

19.20

Excavate to form pit or trench, commencing from reduced level

2. Basement Excavation
Excavate to form basement, commencing from reduced level
a) ne 2.00m deep
b) 2.00 - 4.00m deep

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/20
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

3. Cutting
Excavate to form embankment, commencing from reduced level
a) generally

m3

7.20

4. Break Up Obstructions
Extra over excavation for breaking up obstruction using mechanical means
m3

22.20

b) mass concrete

37.10

c) reinforced concrete

m3

66.80

83.50

a) tarmacadam surface

m3

16.70

b) mass concrete

m3

44.50

66.80

33.40

a) brickwork and blockwork

d) rock

5. Break Up Surface Obstructions


Break up surface pavement

c) reinforced concrete
d) brickwork and blockwork

m
m

Cut surface pavement using pavement diamond cutter to achieve a straight edge
e) ne 150mm deep

16.00

C. FILLING
1. Backfilling
Backfilling around trench, column base, pile cap, foundation beam and pier hole
a) excavated material obtained within the site
b) earthfilling obtained from contractor's own source

m3

5.60

15.00

2. Filling and Forming Embankments


Deposit, spread, level, compact and consolidate in layers of 150mm thick to make up
levels
a) excavated material obtained within the site

m3

4.80

b) earthfilling obtained from contractor's own source

m3

14.00

a) hardcore, including blinding with sand

m3

56.50

b) quarry waste

m3

58.70

51.20

3. Hardcore and Aggregate


Spread, level, compact, ram and consolidate

c) quarry dust (aggregate size 5mm down)

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/21
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________
3

d) granite aggregate, including blinding with quarry waste


e) unwashed sand

63.60

40.00

m3

9.90

24.90

D. DISPOSAL
1. Excavated Material
Remove excavated material off site
a) for suitable excavated material
b) for unsuitable excavated material

E. SURFACE TREATMENT
1. Trimming
Trim, level and grade excavated soil or make up level to required cambers and
gradients
m2

0.70

1.60

a) grade 10

m3

152.00

b) grade 15

155.00

c) grade 20

m3

158.00

a) grade 20

m3

161.00

b) grade 25

m3

163.00

c) grade 30

m3

166.00

d) grade 35

168.00

e) grade 40

m3

171.00

173.00

175.00

a) horizontal surface
b) vertical surface

III.

CONCRETE WORK

A. IN-SITU CONCRETE
1. Lean/Mass Concrete
Lean or Mass concrete complying with BS 8110

2. Reinforced Concrete
Reinforced concrete complying with BS 8110

f)

grade 45

g) grade 50

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/22
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________
3

h) grade 55

178.00

3. Waterproofed Concrete
Waterproofed concrete complying with BS 8110 with approved waterproofing
compound
a) grade 30

m3

181.00

b) grade 35

196.00

a) 6mm diameter

kg

1.60

b) 10mm diameter

kg

1.55

c) 13mm diameter

kg

1.50

d) 16mm diameter

kg

1.40

e) 20mm diameter

kg

1.39

f)

22mm diameter

kg

1.38

g) 25mm diameter

kg

1.37

h) 28mm diameter

kg

1.36

i)

kg

1.36

10mm diameter

kg

1.50

k) 13mm diameter

kg

1.45

l)

16mm diameter

kg

1.40

m) 20mm diameter

kg

1.30

n) 22mm diameter

kg

1.29

o) 25mm diameter

kg

1.28

p) 28mm diameter

kg

1.27

q) 32mm diameter

kg

1.26

r)

40mm diameter

kg

1.26

s) 50mm diameter

kg

1.26

B. REINFORCEMENT
1. Bar Reinforcement
Mild steel bar reinforcement complying with SS 18

32mm diameter

High tensile steel bar reinforcement complying with SS 2


j)

2. Fabric Reinforcement
Welded steel fabric reinforcement complying with SS 32 and well lapped (measured
nett)
a) Reference No A5

ISSUE NO: JUNE 2009

m2

5.44

CONTRACT VT297D

FSR/23
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________
2

b) Reference No A6

7.13

8.98

d) Reference No A8

11.54

e) Reference No A9

m2

14.41

17.64

g) Reference No B5

10.18

h) Reference No B6

m2

11.56

13.17

17.03

m2

19.90

23.13

m) Reference No B11

26.71

n) Reference No B12

m2

30.77

o) Reference No B13

37.95

p) Reference No D6

13.64

q) Reference No D7

m2

17.36

22.49

s) Reference No D9

m2

28.25

t)

Reference No D10

m2

34.71

u) Reference No D11

41.89

v) Reference No D12

m2

49.73

c) Reference No A7

f)

i)
j)

Reference No A10

Reference No B7
Reference No B8

k) Reference No B9
l)

r)

Reference No B10

Reference No D8

C. PRECAST CONCRETE
1. Kerb or Divider
Precast concrete kerb or divider in Grade 25 concrete including laying in alignment
and finishing fair on all exposed surfaces
a) 125 x 300mm Type K2 Kerb

14.15

b) 150 x 300mm Type D1 Divider

16.20

Extra over 125 x 300mm Type K2 Kerb for 125 x 300 x 980mm long, Type K2 Kerb
with scupper mouth
c) generally

No

2.05

2. Cover Slab
Precast concrete Grade 30 cover slab all as detailed in Drawing Nos.
LTA/RD/SD99/DRA/9&10
a) 640 x 270 x 75mm
ISSUE NO: JUNE 2009

No

8.70

CONTRACT VT297D

FSR/24
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

D. FORMWORK
1. Sawn Formwork
Sawn formwork to in-situ concrete including strutting not exceeding 3.5m high
a) curved surface
b) plain surface

m2

32.50

28.20

2. Wrought Formwork
Wrought formwork to in-situ concrete including strutting not exceeding 3.5m high
a) curved surface
b) plain surface

m2

40.40

35.00

m2

3.90

3. Strutting
Extra over for strutting exceeding 3.50m high
a) Every 1.50m high
E. WATER PROOFING TO CONCRETE
1. Damp Proof Membrane
Waterproofing sheet laid to top, side or underside of concrete structure
a) Medium weight (Basic wt: 280g/m2 ) approved building
paper
b) Heavy weight (Basic wt: 527g/m2) approved building
paper

m2

4.50

m2

4.90

2. Water-stops
PVC water-stop embedded in concrete at interfaces of structural elements
a) 200mm wide

23.70

b) 250mm wide

29.00

m2

7.40

a) 12mm thick

4.20

b) 20mm thick

4.50

3. Protection
Polystyrene board fixed to external surface of concrete
a) 25mm thick, 16 kg/m3 grade
F. SUNDRIES
1. Expansion Joints
75mm high bitumen impregnated fibreboard joint filler

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/25
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

c) 25mm thick

5.70

d) 10mm diameter

2.20

e) 15mm diameter

2.40

f)

2.70

g) 15mm deep

13.50

h) 25mm deep

20.80

Polyethylene bond breaking strip to joint

25mm diameter

25mm wide polysulphide sealer to joint

2. Trowelling
Labour trowel top surface of concrete to a smooth finish including additional cement
m2

a) generally

3.30

3. In-situ Kerbs
Concrete kerb finished fair on all exposed surfaces including formwork, angles, ends
and intersections per 1000 mm2 cross sectional area
a) grade 20

0.40

b) grade 25

0.45

c) grade 30

0.50

4. Cutting To Concrete
Labour in cutting reinforced concrete to form groove not exceeding 100mm wide
including rendering with cement mortar (1:3)
a) ne 50mm deep

7.20

b) 50 - 100mm deep

14.20

5. Demolition
Break up existing concrete structure including cutting and bending reinforcement and
removal of debris off site
a) opening ne 0.10 m3
b) opening 0.10 - 0.20m

c) opening exceeding 0.20m

ISSUE NO: JUNE 2009

No

53.70

No

70.90

355.00

CONTRACT VT297D

FSR/26
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

IV. BRICKWORK AND BLOCKWORK


A. CLAY BRICKS
1. Common Brickwork (Standard Size)
Common brick (standard size 215 x 102.5 x 65mm) complying with SS 103 in
cement mortar (1:4) with mortar plasticiser
a) 65mm thick wall

m2

20.50

b) Half brick thick wall

m2

31.40

c) One brick thick wall

59.30

d) Half brick thick wall built honeycombed with selected


brick

m2

30.50

e) Extra over common brick-work for building fair face one


side

m2

4.40

2. Common Brickwork (Modular Size)


Common brick in modular size 190 x 90 x 90mm (Type M211) complying with SS
103 in cement mortar (1:4) with mortar plasticiser
a) Half brick thick wall

m2

23.90

b) One brick thick wall

m2

47.80

3. Engineering Brickwork
Engineering brick (standard size 215 x 102.5 x 65mm) complying with BS 3921
Class A with 69 N/mm2 compressive strength in cement mortar (1:4) with mortar
plasticiser
a) Half brick thick wall

m2

69.50

b) One brick thick wall

141.00

4. Facing Brickwork
First grade red facing brick (standard size 215 x 102.5 x 65mm) complying with SS
103 in cement mortar (1:4) with mortar plasticiser
a) One brick thick wall, pointed on one side
b) One brick thick wall, pointed on both sides

m2

111.40

114.00

B. CONCRETE BLOCKS
1. Hollow Blockwork
Hollow concrete block complying with SS 76M in cement mortar (1:4) with mortar
plasticiser
a) 75mm thick wall

ISSUE NO: JUNE 2009

m2

18.00

CONTRACT VT297D

FSR/27
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________
2

b) 100mm thick wall

19.60

c) 150mm thick wall

32.00

d) 150mm thick wall built honeycombed with fair face both


sides

m2

27.50

2. Vent Blockwork
Precast concrete vent block complying with SS 76M in cement mortar (1:4) with
mortar plasticiser
a) 100mm thick wall

m2

60.40

b) 150mm thick wall

m2

67.70

3. Autoclaved Aerated Blockwork


Block size 590 x 190mm complying with SS 76M in cement mortar (1:4) with mortar
plasticiser
a) 75mm thick wall
b) 100mm thick wall

m2

27.40

33.10

C. GLASS BLOCKS
1. Walls/Panels
Glass block in wall or panel in cement mortar (1:4) with mortar plasticiser
a) 150 x 150 x 100mm thick

m2

292.00

b) 190 x 190 x 100mm thick

230.00

D. SUNDRIES
1. Damp Proof Courses
3 ply bituminous felt horizontal damp proof course complying with BS 743 Type B in
cement mortar (1:4) with mortar plasticiser to wall
a) 112.5mm wide

b) 225mm wide

c) exceeding 300mm wide

3.40
5.60
2

13.30

2. Cutting to Brickwork and Blockwork


Labour in cutting brickwork and blockwork to form groove not exceeding 100mm
wide including rendering with cement mortar (1:3)
a) ne 50mm deep

7.90

b) 50 - 100mm deep

11.90

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/28
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

3. Demolition
Break up existing masonry structure including removal of debris off site
a) opening ne 0.10m3 (taking down with care)

No

8.40

b) opening 0.10 - 0.20m3 (taking down with care)

No

14.20

m3

30.90

c) opening exceeding 0.20m or general unrestricted


demolition

V. ROOFING
A. TILE ROOFING
1. Clay Roof Tiles
Natural tone Marseille profile clay roofing tile complying with SS 70 fixed to battens
(measured separately) with galvanised nails at approximately 400mm centres
m2

42.50

b) ridge or hip tile

31.60

c) right/left hand verge tile

56.90

d) hip end or ridge start tile

No

62.30

e) apex tile

No

122.70

a) 1-ply felt; 17.75 kg per 20m2

m2

22.50

b) 2-ply felt; 35.50 kg per 20m for each layer

45.30

c) 3-ply felt; first and second layers each weighing 27 kg


per 20m2 and third layer weighing 45 kg per 20m2

m2

60.70

d) 1-ply felt; 17.75 kg per 20m2

9.40

e) 2-ply felt; 35.50 kg per 20m for each layer

25.00

f) 3-ply felt; first and second layers each weighing 27 kg


per 20m2 and the third layer weighing 45 kg per 20m2

31.50

a) generally
Extra over Marseille for roof accessory

B. BUILT-UP ROOFING
1. Felt Roofs
Bituminous felt roofing on flat roof including sealing and bonding

150mm high bituminous felt skirting including sealing and bonding

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/29
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

C. PROFILED SHEET ROOFING OR CLADDING


1. Steel Deckings
High tensile profile patent Colorbond/colorcote with zincalume coating roof or wall
cladding fixed to steel or timber framing (measured separately) with fixing clips and
self-tapping screws
a) 0.47mm thick sheet

m2

31.10

b) 0.53mm thick sheet

m2

34.70

D. RAINWATER GOODS
1. Flashings/Cappings
0.61mm thick galvanised steel standard rainwater goods with zincalume coating and
colorbond finish including fixing clips, bolts and nails
a) 300mm girth flashing

18.30

b) 500mm girth capping

26.10

2. Gutters
1mm thick galvanised steel open box gutter with zincalume coating and colorbond
finish including brackets, fixing clips, bolts, nails and laying to falls
a) 600mm girth gutter

42.70

b) 1200mm girth gutter

76.50

Unplasticised polyvinyl chloride half-round gutter including brackets, fixing clips, bolts,
nails and laying to falls
c) 150mm diameter

32.30

d) 200mm diameter

36.40

3. UPVC Downpipes
Unplasticised polyvinyl chloride rainwater downpipe including solvent welded joints
and jointing to sumps and drains
a) 100mm diameter

11.80

b) 150mm diameter

16.00

c) 100mm diameter bend/elbow

No

6.70

d) 150mm diameter bend/elbow

No

12.80

e) 100mm diameter swan-neck

No

32.90

f)

No

40.10

g) 100mm diameter shoe

No

20.90

h) 150mm diameter shoe

No

41.50

Extra over for fitting

150mm diameter swan-neck

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/30
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

4. Spout Outlets
Rainwater spout outlet with removable cast iron dome grating and luted flange
including jointing to rainwater downpipes and setting in concrete slab to form a
watertight joint
a) 100mm diameter cast iron outlet

No

21.10

b) 150mm diameter cast iron outlet

No

41.30

a) 50mm thick fibreglass insulation, density 16 kg/m3

m2

6.90

b) 50mm thick rock/mineral wool, density 60 kg/m3

m2

15.80

30.20

33.90

E. SUNDRIES
1. Insulation
Insulation material to roof

c) 25mm thick woodwool


d) 50mm thick woodwool
2. Wire Mesh

Wire mesh to roof space including dressing over purlins (measured net)
a) BRC Reference No 3315 (75 x 75 x 1.5mm diameter)

VI.

m2

4.30

STRUCTURAL STEELWORK AND METALWORK

A. STRUCTURAL STEELWORK
1. Mild Steel Members
Mild steel member complying with BS 4360 Grade 43C in stanchion, beam, girder,
roof truss, purlin, cleat and bracket
a) solid section

kg

3.80

b) hollow section

kg

3.90

B. METALWORK
1. Mild Steel Members
Mild steel flat, rod, angle, channel, baluster and rail complying with BS 4360 Grade
43C
a) generally

ISSUE NO: JUNE 2009

kg

3.50

CONTRACT VT297D

FSR/31
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

2. Mild Steel Plain Bolts


Mild steel plain bolts complying with BS 4190 including head, nut and washer
a) 12mm diameter grade 8.8 black bolt, ne 75mm long

No

1.65

b) 12mm diameter grade 8.8 black bolt, 75 - 150mm long

No

2.05

c) 12mm diameter holding down bolt, 300mm long


including grouting

No

12.55

3. Mild Steel Galvanised Bolts


Mild steel galvanised bolt complying with BS 4190 including head, nut and washer
a) 12mm diameter grade 8.8 bolt, ne 75mm long

No

1.70

b) 12mm diameter grade 8.8 bolt, 75 - 150mm long

No

2.05

c) 12mm diameter holding down bolt 300mm long including


grouting

No

12.50

C. VEHICULAR IMPACT GUARDRAIL


1. Vehicular Impact Guardrail
Hot dip galvanised vehicular impact guardrail fixed to steel channel post (post and
support measured separately) including bolt and nut as per Drawing Nos.
LTA/RD/SD99/VIG/1A to 2A
a) W-Beam 311 x 82.6 x 3mm BMT (Base Metal Thickness)

49.10

b) W-Beam 700mm long end piece

No

72.00

c) Turned-down anchorage Type I (4.05m long) with post


and concrete as per Drawing No. LTA/RD/SD99/VIG/10

No

440.00

2. Post and Support


Post and spacer block with galvanised bolt and nut including concrete foundation, all
necessary excavation, and disposal of excavated material.
a) 150 x 110 x 18 x 4.3mm Hot dip galvanised channel post
cast in concrete foundation as per Drawing No.
LTA/RD/SD99/VIG/2A

Set

100.00

b) 150 x 110 x 18 x 4.3mm Hot dip galvanised channel post


mounted on concrete structure including slip base plate as
per Drawing No. LTA/RD/SD99/VIG/15

Set

210.00

Hot dip galvanised brace support (on one side) including post, spacer, brace with
mild steel plates welded, set in and including concrete foundation, all necessary
excavation, disposal of excavated material as per Drawing Nos. LTA/RD/SD99/VIG/6
to 7
c) 150 150 6mm SHS

ISSUE NO: JUNE 2009

Set

350.00

CONTRACT VT297D

FSR/32
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

3. Extruding head gating terminal


Design, supply and install directive and gating extruding head terminal complete with
extruding head terminal, post, support, foundation, cable-anchor assembly, W-beam
and all necessary fixings as per Drawing Nos. LTA/RD/SD99/VIG/10-12
a) Type 2 - 15.2m long extruding head gating terminal as
per Drawing No. LTA/RD/SD99/VIG/10 in compliance
with NCHRP 350 Test level 3

Set

6,400.00

b) Type 3 - 10.1m long cable anchored terminal as per


Drawing No. LTA/RD/SD99/VIG/11

Set

8,300.00

c) Type 4 - 4.0m long cable anchored trailing terminal as


per Drawing No. LTA/RD/SD99/VIG/12

Set

4,500.00

Design, supply and install redirective and non-gating crash attenuator in compliance
with NCHRP 350 Test level 3 complete with extruding head terminal, post, support,
foundation, W-beam, Thrie beam and all necessary fixings as per Drawing No.
LTA/RD/SD99/VIG/13
d) Crash cushion

Set

34,000.00

e) Type 5 - Thrie Beam consisting of W-thrie transition


piece, thrie beam and end piece (total length about 6m)

Set

4,750.00

D. RAILING
1. Aluminium Alloy Railing
Aluminium alloy railing in powder coating finish consisting of tubular or square hollow
section set in and including concrete foundation, all necessary excavation and
disposal of excavated material from site as per Drawing Nos. LTA/RD/SD99/RAL/1B
- 2B
a) type A

190.00

b) type B

173.00

c) type C

150.00

d) type D

180.00

E. GRATING
1. Pedestrian Grating
Mild steel grating in panels consisting of 80 x 38 x 4.6mm galvanised steel angle
frame, with 35 x 9mm galvanised mild steel flat all round, in filled with 25 x 5mm
galvanised mild steel flat, all joints and intersections whole welded, drilled and
including painting with one coat of inhibitive primer before delivery and built into
concrete surround including 3mm thick galvanised chequer plate cover as per
Drawing Nos. LTA/RD/SD99/GRA/1 to 3
a) generally

ISSUE NO: JUNE 2009

m2

258.50

CONTRACT VT297D

FSR/33
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

2. Vehicular Grating
Mild steel grating in panels consisting of 100 x 75 x 9.4mm thick galvanised angle
frame with 65 x 9mm fish-tailed mild steel flat welded at 30mm centres and infilled
with 12mm diameter mild steel bars at 85mm centres, all joints and intersections
whole welded, drilled and including painting with one coat of inhibitive primer before
delivery, built into concrete surround as per Drawing Nos. LTA/RD/SD99/GRA/4 & 5
a) generally

m2

640.00

3. Aluminium Rung
300 x 230mm aluminium rung as per Drawing No. LTA/RD/SD99/DRA/4A fixed to
concrete wall in drain including drilling and grouting with cement mortar (1:3)
a) 25mm diameter

No

18.50

kg

1.10

a) General Surfaces

m2

12.00

b) Pipes, bars, angles not exceeding 100mm girth

1.35

c) Ditto exceeding 100mm and not exceeding 200mm girth

2.00

d) Ditto exceeding 200mm and not exceeding 300mm girth

2.50

F. SURFACE TREATMENT
1. Hot Dip Galvanising
Hot dip galvanising complying with SS 117 to structural steelwork
a) generally
2. Powder Coating Finish
Powder coating finish to metalwork complying with BS 4842

VII.

WALL & FLOOR FINISHES

A. WALL & FLOOR FINISHES


1. Smooth Finished Plaster
Cement and sand (1:4) plaster mixed with mortar plasticiser to concrete or brick
surface including trowelling smooth
a) 13mm thick

m2

12.30

b) 20mm thick

m2

13.80

Cement and Sand (1:3) plaster mixed with mortar plasticiser and waterproofing
compound to concrete or brick surface including trowelling smooth
c) 13mm thick

m2

14.20

d) 20mm thick

16.60

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/34
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

2. Screed Bed
Cement and sand (1:3) screed to concrete or brick surface to receive wall finishes
a) 13mm thick

m2

9.20

b) 20mm thick

m2

10.70

3. Aggregate Plaster
Granite aggregate plaster consisting of cement and granite chippings (1:2) with
mortar plasticiser to concrete or brick surface including scrubbing to produce
exposed aggregate finish
a) 20mm thick

m2

23.90

b) 25mm thick

27.10

a) average 20mm thick

m2

11.20

b) average 25mm thick

12.20

13.60

4. Plain Paving
Cement and sand (1:3) paving including trowelling smooth

c) average 32mm thick

20mm thick cement and sand (1:3) skirting with splayed or rounded top edge and
coved bottom including trowelling smooth
d) 100mm high

4.90

e) 150mm high

5.60

5. Waterproofed Paving
Waterproofed cement and sand (1:3) paving with waterproofing compound including
trowelling smooth
a) average 20mm thick

m2

13.30

b) average 25mm thick

m2

14.90

c) average 32mm thick

17.10

d) average 38mm thick

19.00

e) average 50mm thick

m2

22.70

20mm thick cement and sand (1:3) skirting with waterproofing compound including
splayed or rounded top edge and coved bottom and trowelling smooth
f)

100mm high

5.10

g) 150mm high

5.90

6. Hardened Paving
25mm thick cement and sand (1:3) paving mixed with hardener including trowelling
smooth
a) light duty non-metallic hardener (3kg per m2)

ISSUE NO: JUNE 2009

m2

16.70

CONTRACT VT297D

FSR/35
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________
2
2

b) heavy duty non-metallic hardener (7kg per m )

22.00

7. Granolithic Paving
Granolithic aggregate paving consisting of cement, sand and granite chippings of
5mm gauge (2:1:5) set out in panels with 15 x 15mm deep recessed joints laterally at
1.20m centres including scrubbing to produce exposed aggregate finish
a) 25mm thick

m2

28.50

b) 32mm thick

32.30

36.50

a) 20mm thick

m2

9.80

b) 25mm thick

10.80

c) 32mm thick

m2

12.20

c) 40mm thick
8. Screed Bed
Cement and sand (1:3) screed to receive floor finishes

B. TILE FINISHES
1. Glazed Tiles
Supply and lay white glazed wall tile complying with SS 301 including pointing with
white cement
a) 5mm thick

m2

60.00

2. Labour for Tiling


Supply labour and mortar for laying tiles to wall including pointing with white cement
a) generally

m2

15.80

Supply labour and mortar for laying tiles to floor including painting with white cement
b) generally

m2

15.80

C. PAVING BLOCK
1. Concrete Interlocking Paving Block
Precast concrete interlocking paving block of any pattern including filling joints with
dry and sharp sand and 50mm thick bedding sand
a) 60mm thick

m2

35.30

b) 80mm thick

36.70

c) 100mm thick

m2

38.80

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/36
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

D. SUNDRIES
1. Hacking Wall Finishes
Hack off existing wall finishes of any thickness including removal of debris off site
m2

4.30

b) tiled finishes

2.80

c) tiled finishes including screed backing

m2

4.50

a) plaster

2. Hacking Floor Finishes


Hack off existing floor finishes of any thickness including removal of debris off site
m2

5.20

b) tiled finishes

3.30

c) tiled finishes including screed bed

m2

6.30

a) paving

VIII. PLUMBING
A. SANITARY PIPEWORK
1. UPVC Pipes
Unplasticised polyvinyl chloride soil, waste, ventilating and anti-syphonage pipe
complying with SS 213 including solvent cement joints
a) 32mm diameter

6.50

b) 40mm diameter

7.80

c) 50mm diameter

8.70

d) 80mm diameter

11.50

e) 100mm diameter

12.90

f)

19.10

g) 32mm diameter bend/elbow

No

2.30

h) 40mm diameter bend/elbow

No

2.70

i)

50mm diameter bend/elbow

No

3.30

j)

80mm diameter bend/elbow

No

5.70

k) 100mm diameter bend/elbow

No

5.90

l)

150mm diameter bend/elbow

No

13.90

m) 32 x 32 x 32mm diameter tee

No

3.20

n) 40 x 40 x 40mm diameter tee

No

4.60

150mm diameter

Extra over for fitting

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/37
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

o) 50 x 50 x 50mm diameter tee

No

5.10

p) 80 x 80 x 100mm diameter tee

No

8.00

q) 100 x 100 x 100mm diameter tee

No

9.50

r)

No

29.80

s) 40 x 32mm diameter reducer

No

3.40

t)

50 x 40mm diameter reducer

No

4.00

u) 80 x 50mm diameter reducer

No

7.30

v) 100 x 80mm diameter reducer

No

10.00

w) 150 x 100mm diameter reducer

No

14.80

150 x 150 x 150mm diameter tee

B. WATER SERVICE PIPEWORK


1. Galvanised Steel Pipes
Medium duty galvanised steel pipe complying with BS 1387 with approved internal
lining including screw joints
a) 15mm diameter

15.90

b) 20mm diameter

20.20

c) 25mm diameter

25.00

d) 32mm diameter

32.50

e) 40mm diameter

37.20

f)

50mm diameter

39.70

g) 65mm diameter

53.80

h) 80mm diameter

72.00

Extra over for fitting


i)

15mm diameter bend/elbow

No

4.00

j)

20mm diameter bend/elbow

No

4.20

k) 25mm diameter bend/elbow

No

5.30

l)

32mm diameter bend/elbow

No

7.40

m) 40mm diameter bend/elbow

No

10.60

n) 50mm diameter bend/elbow

No

11.80

o) 65mm diameter bend/elbow

No

20.80

p) 80mm diameter bend/elbow

No

30.10

q) 15 x 15 x 15mm diameter tee

No

6.50

r)

20 x 20 x 20mm diameter tee

No

6.80

s) 25 x 25 x 25mm diameter tee

No

8.30

t)

No

10.60

32 x 32 x 32mm diameter tee

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/38
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

u) 40 x 40 x 40mm diameter tee

No

11.10

v) 50 x 50 x 50mm diameter tee

No

15.40

w) 65 x 65 x 65mm diameter tee

No

19.00

x) 80 x 80 x 80mm diameter tee

No

27.00

y) 20 x 15mm diameter reducer

No

6.70

z) 25 x 20mm diameter reducer

No

7.00

aa) 32 x 25mm diameter reducer

No

10.10

ab) 40 x 32mm diameter reducer

No

10.50

ac) 50 x 40mm diameter reducer

No

14.00

ad) 65 x 50mm diameter reducer

No

22.00

2. Ductile Iron Pipes


Ductile iron pipe complying with BS 4772 Class K9 with internal lining including
spigot and socket joints
a) 80mm diameter

48.40

b) 100mm diameter

56.10

c) 150mm diameter

73.10

d) 80mm diameter bend/elbow

No

41.40

e) 100mm diameter bend/elbow

No

52.00

f)

150mm diameter bend/elbow

No

72.40

g) 80 x 80 x 80mm diameter tee

No

52.90

h) 100 x 100 x 100mm diameter tee

No

63.90

i)

150 x 150 x 150mm diameter tee

No

101.00

j)

100 x 80mm diameter reducer

No

40.30

No

62.60

Extra over for fitting

k) 150 x 100mm diameter reducer


C. PIPE FITTINGS
1. Bibcocks/Stopcocks

Brass screwdown bibcock or stopcock complying with SS 75 including crutch handle


and accessories
a) 15mm diameter

No

13.20

b) 20mm diameter

No

23.60

c) 25mm diameter

No

57.70

d) 32mm diameter

No

62.90

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/39
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

e) 40mm diameter

No

88.70

f)

50mm diameter

No

144.20

g) 65mm diameter

No

194.90

a) 65mm diameter

No

129.10

b) 80mm diameter

No

172.10

a) 80mm diameter

No

147.20

b) 100mm diameter

No

166.00

c) 150mm diameter

No

304.90

m2

5.80

m2

4.00

b) two coats of stain and two coats of wax polish

5.10

c) two coats of varnish

m2

6.30

d) one coat of aluminium wood primer, one undercoat and


two finishing coats of enamel paint

m2

8.40

a) one coat anti-rust paint, one undercoat and two coats of


aluminium paint

m2

10.00

b) one coat of zinc chromate primer, one undercoat and


two finishing coats of synthetic enamel paint

m2

10.60

2. Gate Valves
Brass gate valve complying with BS 5154 including wheel handle

3. Sluice Valves
Cast iron sluice valve complying with BS 5163

IX.

PAINTING

A. PAINTING
1. Concrete or Plastered Surfaces
Painting concrete or plastered surface and the like
a) one coat of oil based anti-alkali sealer, one undercoat
and two finishing coat of acrylic emulsion paint
2. Timber Surfaces
Painting timber surface
a) two coats of aluminium wood primer

3. Metal Surfaces
Painting metal surface

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/40
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

4. Weldmesh Surfaces
Painting on both sides of weld-mesh (measured flat on one side)
a) one coat of anti-rust paint, one undercoat and two coats
of aluminium paint

m2

6.80

b) one coat of zinc chromate primer, one undercoat and


two finishing coats of synthetic enamel paint

m2

7.60

5. Cast Iron Pipe Surfaces


Knot and apply one coat of aluminium primer, one undercoat and two finishing coats
of synthetic enamel paint
a) small pipe

1.70

b) large pipe

3.00

6. Galvanised Pipe Surfaces


One coat of zinc chromate primer, one undercoat and two finishing coats of synthetic
enamel paint
a) small pipe

2.00

b) large pipe

3.70

7. Road Marking
One coat of 1.5mm thick thermoplastic paint on road pavement as per Drawing No.
LTA/RD/SD99/RMS1&2
a) 100mm wide line

1.90

b) 150mm wide line

2.80

c) 200mm wide line

3.70

d) 300mm wide line

e) exceeding 300mm wide line

5.60
2

13.20

One coat of 3.0mm thick thermoplastic paint on road pavement as per Drawing Nos.
LTA/RD/SD99/RMS/1 to 3
f)

200mm wide line

6.50

g) 300mm wide line

8.50

h) exceeding 300mm wide line

m2

24.70

i)

go-straight arrow

No

44.00

j)

go-straight with right/left turn arrow

No

50.60

k) right/left turn arrow

No

39.80

l)

No

36.70

merge arrow

Erase existing thermoplastic road lines and markings including clearing all shavings
and making good

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/41
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________
2

m) generally

X.

15.00

DRAINAGE WORK

A. DRAINAGE WORK
1. Drain Excavation
Excavate trench minimum 340mm wide for 100mm diameter pipe, not exceeding
2.00m deep including backfilling and disposal of surplus excavated material
a) average 600mm deep

10.40

b) average 1000mm deep

17.30

c) average 1500mm deep

33.30

Excavate trench minimum 490mm wide for 150mm diameter pipe including
temporary supports, backfilling and disposal of surplus excavated material
d) ne 2.00m deep, average 1.50m deep

36.30

e) 2.00 - 4.00 m deep, average 3.00m deep

56.30

2. Benchings & Haunchings


125mm Thick concrete (Grade 30) bed under 250mm UPVC scupper pipe including
haunching to half height of pipe carried up and splayed tangentially and all
necessary formwork, reinforcement and lean concrete
a) 450mm wide, under 250mm diameter scupper pipe

40.00

B. SUB-SOIL PIPES OR DRAINS


1. UPVC Pipes
Heavy duty unplasticised polyvinyl chloride Class AW subsoil pipes 3/4 perforated
a) 100mm diameter

17.60

b) 150mm diameter

29.10

m3

95.20

m2

7.70

2. Filling Materials
a) Graded stone 19mm size
3. Drainage Layer
a) Geocomposite drainage layer as per Drawing Nos.
LTA/RD/SD99/DRA/2, 4A, 5A & 6A

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/42
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

C. PRECAST CONCRETE CULVERTS


1. Pipe Culverts
Precast concrete pipe culverts Class 'L' complying with SS 183 butt jointed with
cement and sand (1:1) mortar
a) 300mm diameter

60.80

b) 450mm diameter

88.60

c) 600mm diameter

126.80

d) 750mm diameter

194.40

e) 900mm diameter

246.50

f)

1050mm diameter

291.00

g) 1200mm diameter

352.50

h) 1350mm diameter

427.40

i)

1500mm diameter

534.60

j)

1800mm diameter

786.70

Precast concrete pipe culverts Class 'M' complying with SS 183 butt jointed with
cement and sand (1:1) mortar
k) 300mm diameter

68.70

l)

450mm diameter

101.50

m) 600mm diameter

143.10

n) 750mm diameter

199.30

o) 900mm diameter

295.00

p) 1050mm diameter

342.60

q) 1200mm diameter

437.20

r)

1350mm diameter

515.20

s) 1500mm diameter

618.30

t)

884.80

1800mm diameter

D. PRECAST CONCRETE DRAINS


1. Base Section of 'U' Drain
Precast concrete 'U' drain base section laid to even falls and jointed in cement and
sand (1:3) mortar, internal size
a) 600 x 600mm

143.50

b) 750 x 600mm

165.00

c) 900 x 600mm

201.70

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/43
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

d) 1000 x 600mm

258.30

e) 1200 x 600mm

291.10

2. Composite Channels
Precast concrete composite channel or block drains laid to even falls and jointed in
cement and sand (1:3) mortar
a) Type C1

6.70

b) Type C2

7.00

c) Type C3

8.90

d) Type C4

9.70

e) Type C5

11.40

f)

11.00

g) Type C6

15.20

h) Type C7

23.70

i)

Type C7A

20.40

j)

Type C7B

16.80

k) Type C8A

60.30

l)

62.30

m) Type B1

19.50

n) Type B2

25.60

o) Type B3

68.00

Type C5A

Type C8B

Precast concrete channel laid in precast 'U' drain base sections or precast concrete
culverts including concrete grade 20 benching
p) Type C5A

18.30

3. Scupper Drain and Pipe


Scupper drain or pipe laid to even falls jointed in cement and sand (1:3) mortar
a) Type S1 drain

26.50

b) 250mm diameter UPVC Pipe to SS272

24.00

c) 250mm diameter heasy duty UPVC pipe class AW

56.00

a) 65mm diameter ne 300mm long

No

1.10

b) 65mm diameter exc 300mm long

3.60

c)

No

1.20

4.20

4. Weepholes
Supply and fix UPVC pipe to SS213 as weephole

75mm diameter ne 300mm long

d) 75mm diameter exc 300mm long

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/44
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

E. SUNDRIES
1. Drop Inlet Chamber
Precast concrete drop inlet chamber including hot dip galvanised mild steel framing
and grating laid on compacted sub-base and including forming proper connection to
scupper pipe as per Drawing No. LTA/RD/SD99/DRA/7C
a) 750 x 275 x 325mm Internal size

No

180.00

2. Sump
Precast concrete sump for sub-soil drain including proper connections, concrete
benching and precast concrete cover slabs, internal size
a) 550 x 550 x 1300mm

XI.

No

339.00

m3

60.30

ROADS AND PAVING

A. PAVEMENT
1. Sub-base
Sub-base material
a) generally
2. Base Course
Coarse granite aggregate (crusher-run) base course and blinded with fine aggregate
a) generally

m3

102.50

m3

107.50

Graded granite aggregate base course


b) generally
3. Asphalt Concrete
Supply and lay hot-mix asphalt concrete base, binder or wearing course
a) mix-specification type B1

95.00

b) mix-specification type W1

95.00

c) mix-specification type W3

95.00

Supply and lay hot-mix asphalt concrete base course mix-specification type B1
d) 75mm (consolidated) thick

m2

16.75

e) 90mm (consolidated) thick

20.10

26.80

f)

120mm (consolidated) thick

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/45
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

Supply and lay hot-mix asphalt concrete wearing course mix-specification type
W3/W1
g) 25mm (consolidated) thick

m2

5.60

h) 40mm (consolidated) thick

8.95

11.20

i)

50mm (consolidated) thick

4. Sundries
Brush, sweep and thoroughly clean to remove all loose and superfluous materials
and ensure a perfectly dry surface prior to the application of the tack coat and
asphalt concrete
a) existing bitumen or concrete surfaces

XII.

m2

0.10

OTHER EXTERNAL WORKS AND SERVICES

A. FENCING
1. Chain Link Fences
50mm x 50mm mesh 8 SWG PVC coated galvanised steel chain link fencing
complete with 50 x 50 x 6mm thick mild steel angle post spaced at approximately
3.00m centres, and bedded into and including 300 x 300 x 675mm deep concrete
(grade 15) base including straining fittings and running three strands of 6 SWG PVC
coated galvanised straining wires between posts and four strands of pvc coated
galvanised barbed wires along top of fencing including painting mild steel fence
posts with one coat of red lead primer, one undercoat and two finishing coats of
enamel paint, excavation for concrete base, formwork and disposal of excavated
materials from site
a) 2150mm high overall fence with 2500mm long post

60.00

b) Extra over for 65 x 65 x 6mm thick mild steel angle


corner or intermediate post, 2500mm long overall supported
with and including two 50 x 50 x 6mm thick mild steel angle
inclined struts each 2150mm long twice drilled and with top
end bolted to corner or inter-mediate post, with foot of post
and strut bedded into and including concrete (grade 15)
bases size 300 x 300 x 675mm deep and 450 x 300 x
525mm deep respectively including painting mild steel angle
posts and struts with one coat of red lead primer, one
undercoat and two finishing coats of enamel paint,
excavation, formwork, and disposal of excavated materials
from site

No

142.80

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/46
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

c) Extra over for 65 x 65 x 6mm thick mild steel angle end


post, welded to steel tubular gate post and supported with
and including one 50 x 50 x 6mm thick mild steel angle
inclined strut, twice drilled, once cranked and once bolted to
end post, with foot of post bedded to concrete base of gate
post(measured separately) and foot of strut bedded into and
including concrete (grade 15) base size 450 x 300 x 525mm
deep including painting mild steel angle posts and struts with
one coat of red lead primer, one undercoat and two finishing
coats of enamel paint, excavation, formwork, and disposal of
excavated materials from site

No

68.50

B. STREET FURNITURE
1. Directional Signs
Single-face directional signs comprising aluminium sheeting 14SWG laminated with
approved reflective sheeting including all the required size of letters, numbers, logo(s)
and all necessary backings, welding and other types of connections as per Drawing
Nos. LTA/RD/SD99/SUP/1A-3A (supports to be measured separately)
a) High Intensity Grade
b) Micro Prismatic Reflective Grade

m2

494.00

602.00

Supports including foundation, excavation and disposal as per Drawing nos.


LTA/RD/SD99/SUP/1A-3A
c) 75mm diameter cantilever supports (Type A)

No

400.00

d) a pair of 100 x 100 x 6mm SHS supports (Type B)

No

2,800.00

e) a pair of 120 x 120 x 8mm SHS supports (Type C)

No

3,400.00

f)

No

3,700.00

a pair of 150 x 150 x 6mm SHS supports (Type D)

2. Traffic Signs
Single-faced silk screen traffic signs as regulatory signs, warning signs and
informative signs comprising 2mm thick aluminium sheets, approved Micro Prismatic
Grade reflective sheetings including appropriate diagrams, alphabets and numerals
(supports to be measured separately)
a) size 600 x 450mm

No

160.00

b) size 600 x 600mm

No

197.00

c) size 600 x 900mm

No

305.00

ISSUE NO: JUNE 2009

CONTRACT VT297D

FSR/47
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

Supports for traffic signs


d) Supply and install 50 x 50 x 2.3mm thick galvanised
square hollow section vertical supports of traffic signs to all
details as shown in Drawing No. LTA/RD/SD99/SUP/8
including excavation, if any, and disposal of excavated
materials from site, fixing and fastening of maximum three
traffic signs on any one face per support, using 400 x 400 x
400mm concrete foundation with built in expansion bolts

No

92.00

C. SUNDRIES
1. Turfing
Turfing consisting of grass, size 300 x 300mm not less than 50mm thick, including
50mm thick topsoil and sludge (3:1) top dressing
a) spot turf on horizontal surface

m2

4.90

b) close turf on embankment exceeding 15 from the


horizontal

m2

6.10

2. Pipes For Street Lighting


Excavation for concrete foundation, disposal of excavated materials from site,
concrete foundation shall be measured separately.
Pipe crossing complete with pilot fish wire excluding long bends.
a) 75mm diameter medium duty galvanised iron pipe

24.20

b) 75mm diameter heavy duty galvanised iron pipe

29.00

c) 75mm diameter Class AW heavy duty PVC pipe

10.50

d) 75mm diameter Class B heavy duty PVC pipe

6.50

e) 100mm diameter medium duty galvanised iron pipe

34.40

f)

100mm diameter heavy duty galvanised iron pipe

40.40

g) 100mm diameter Class AW heavy duty PVC pipe

14.70

h) 100mm diameter Class B heavy duty PVC pipe

8.50

3. Geotextile Membrane
Approved synthetic geotextile fabric membrane to troughs, french drains etc. well
lapped at joint (measured nett)
a) Type Class B

ISSUE NO: JUNE 2009

m2

2.80

CONTRACT VT297D

FSR/48
ITEM DESCRIPTION

UNIT

RATE ($)

______________________________________________________________________________________________________________

4. Tree Aeration Trough


Excavation for tree aeration trough, disposal of excavated materials from site,
250mm diameter UPVC scupper pipe as shown in Drawing Nos.
LTA/RD/SD99/PNR/2-3 shall be measured separately.
Tree aeration trough consisting of 20mm granite aggregate wrapped around with
approved synthetic geotextile fabric membrane complete with 100mm diameter
perforated UPVC pipes complete with cover and galvanised steel clearing plate
welded to 10mm diameter mild steel rod, as per Drawing Nos. LTA/RD/SD99/PNR/23
a) 2000 x 2000 x 700mm

No

370.00

5. Paving Slabs
Precast concrete (grade 20) paving slab jointed and pointed in cement and sand (1:3)
including 50mm thick sand bed
a) size 300 x 300 x 50mm thick

m2

41.50

6. Aeration Slabs
Precast concrete aeration slab of any pattern with top soil and turfing in voids
including 50mm thick sand bed
a) 65mm thick
b) 100mm thick

ISSUE NO: JUNE 2009

m2

35.00

41.00

CONTRACT VT297D