PILING............................................................................................................. 15
II.
EXCAVATION ................................................................................................. 19
III.
IV.
V.
ROOFING ........................................................................................................ 28
VI.
PAINTING........................................................................................................ 39
X.
XI.
CONTRACT VT297D
FSR/15
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
I.
PILING
A. EQUIPMENT
1. Piling Rigs
Provide and assemble piling equipment on site including moving it around site,
subsequent dismantling and removal on completion
a) rig to install bakau pile
Item
1,200.00
Item
6,000.00
c) rig to install steel 'H' pile (up to 132.44 kg/m type steel
'H'pile)
Item
7,300.00
d) rig to install steel sheet pile (up to 190 kg/m2 type steel
sheet pile)
Item
3,200.00
Item 11,000.00
f)
Item 10,000.00
Item
5,000.00
B. TIMBER PILES
1. Bakau Piles
Supply and drive bakau pile
a) 75mm diameter ne 5.00m long
No
18.00
No
25.00
3.80
2. Mattress Piles
Supply and lay bakau roller
a) 75mm diameter
C. CONCRETE PILES
1. Precast Concrete Piles
Supply and drive precast concrete pile complying with SS CP 4
a) 155 x 155mm cross-section with 25-35t carrying capacity
m
30.00
34.00
38.60
45.60
CONTRACT VT297D
FSR/16
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
54.00
f)
58.50
71.30
Supply and drive steel 'H' piles complying with BS 4360 Grade 43A with corrosion
protection to BS 5493 and BS CP 1021 including extension by weld jointing to BS
5135 and BS 6265
a) size 203 x 203mm x 53.57 kg/m
104.00
118.00
149.00
205.00
250.00
2. Interlocking Piles
Supply and drive temporary steel sheet pile complying with BS 4360 Grade 43A
including strutting, waling, extension by weld jointing to BS 5135 and BS 6265 and
subsequent extraction and removal
a) 400 x 125 x 13mm thick, 150 kg/m2 U-shaped section
2
m2
95.00
95.00
113.00
Supply and drive left in steel sheet pile complying with BS 4360 Grade 43A including
strutting, waling and extension by weld jointing to BS 5135 and BS 6265
d) 400 x 125 x 13.0mm thick, 150 kg/m U-shaped
m2
279.00
274.00
f)
353.00
E. BORED PILES
1. Grade 35 Concrete Piles
Supply and install bored cast in place concrete piles including temporary steel casing
(reinforcement measured separately)
a) diameter 300mm
115.00
b) diameter 400mm
120.00
c) diameter 500mm
128.00
d) diameter 600mm
145.00
CONTRACT VT297D
FSR/17
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
e) diameter 900mm
230.00
f)
diameter 1200mm
335.00
g) diameter 1500mm
460.00
Supply and install bored cast in place concrete piles (temporary steel casing and
reinforcement measured separately)
h) diameter 500mm
115.00
i)
diameter 600mm
140.00
j)
diameter 900mm
215.00
k) diameter 1200mm
300.00
l)
405.00
diameter 1500mm
120.00
b) diameter 400mm
125.00
c) diameter 500mm
130.00
d) diameter 600mm
150.00
e) diameter 900mm
235.00
f)
diameter 1200mm
350.00
g) diameter 1500mm
470.00
Supply and install bored cast in place concrete piles (temporary steel casing and
reinforcement measured separately)
h) diameter 500mm
115.00
i)
diameter 600mm
140.00
j)
diameter 900mm
215.00
k) diameter 1200mm
305.00
l)
410.00
kg
2.10
207.00
diameter 1500mm
3. Steel Casing
a) Supply and drive steel casing to be left in for bored piles
F. MICROPILES
1. Bored Micropiles
Supply and install micropiles
a) 150mm diameter
CONTRACT VT297D
FSR/18
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
b) 200mm diameter
230.00
c) 250mm diameter
288.00
Cutting of pile to the required level including welding of the bearing plate
d) generally
No
189.00
2. Driven Micropiles
Supply and drive steel micropiles complete with cement grouting to centre void
a) 114mm diameter (with working capacity of 20 ton each)
69.00
Cutting of pile to the required level including welding of the bearing plate
b) Generally
No
70.00
G. SUNDRIES
1. Pile Tests
Test loading of piles with the Kentledge reaction system including casting and
subsequent removal of temporary pile cap
a) generally
46.00
No
46.00
No
54.00
No
62.00
No
65.00
No
70.00
f)
No
73.00
No
78.00
No
86.00
i)
No
91.00
j)
No
95.00
No
103.00
No
79.00
2. Pile Shoes
Supply and fix chilled hardened cast iron pointed coaxial pile shoe
114mm diameter
CONTRACT VT297D
FSR/19
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
II.
EXCAVATION
A. SITE CLEARANCE
1. Clear Site Vegetation
Clear bushes, shrubs, undergrowth, saplings, grass, rubbish and small trees not
exceeding 600mm girth including grubbing up roots, filling voids and disposal of
materials off site
a) generally
m2
1.40
2. Remove Trees
Cut tree including grubbing up roots, filling voids and disposal of materials off site
a) 600 - 1000mm girth
No
206.00
No
433.00
No
721.00
No
863.00
m2
0.85
m2
1.30
2.00
7.50
3. Oversite Excavation
Excavate over site, commencing from ground level, to reduce level
5.50
b) ne 2.00m deep
m3
13.00
m3
21.00
29.60
m3
13.30
19.20
2. Basement Excavation
Excavate to form basement, commencing from reduced level
a) ne 2.00m deep
b) 2.00 - 4.00m deep
CONTRACT VT297D
FSR/20
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
3. Cutting
Excavate to form embankment, commencing from reduced level
a) generally
m3
7.20
4. Break Up Obstructions
Extra over excavation for breaking up obstruction using mechanical means
m3
22.20
b) mass concrete
37.10
c) reinforced concrete
m3
66.80
83.50
a) tarmacadam surface
m3
16.70
b) mass concrete
m3
44.50
66.80
33.40
d) rock
c) reinforced concrete
d) brickwork and blockwork
m
m
Cut surface pavement using pavement diamond cutter to achieve a straight edge
e) ne 150mm deep
16.00
C. FILLING
1. Backfilling
Backfilling around trench, column base, pile cap, foundation beam and pier hole
a) excavated material obtained within the site
b) earthfilling obtained from contractor's own source
m3
5.60
15.00
m3
4.80
m3
14.00
m3
56.50
b) quarry waste
m3
58.70
51.20
CONTRACT VT297D
FSR/21
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
3
63.60
40.00
m3
9.90
24.90
D. DISPOSAL
1. Excavated Material
Remove excavated material off site
a) for suitable excavated material
b) for unsuitable excavated material
E. SURFACE TREATMENT
1. Trimming
Trim, level and grade excavated soil or make up level to required cambers and
gradients
m2
0.70
1.60
a) grade 10
m3
152.00
b) grade 15
155.00
c) grade 20
m3
158.00
a) grade 20
m3
161.00
b) grade 25
m3
163.00
c) grade 30
m3
166.00
d) grade 35
168.00
e) grade 40
m3
171.00
173.00
175.00
a) horizontal surface
b) vertical surface
III.
CONCRETE WORK
A. IN-SITU CONCRETE
1. Lean/Mass Concrete
Lean or Mass concrete complying with BS 8110
2. Reinforced Concrete
Reinforced concrete complying with BS 8110
f)
grade 45
g) grade 50
CONTRACT VT297D
FSR/22
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
3
h) grade 55
178.00
3. Waterproofed Concrete
Waterproofed concrete complying with BS 8110 with approved waterproofing
compound
a) grade 30
m3
181.00
b) grade 35
196.00
a) 6mm diameter
kg
1.60
b) 10mm diameter
kg
1.55
c) 13mm diameter
kg
1.50
d) 16mm diameter
kg
1.40
e) 20mm diameter
kg
1.39
f)
22mm diameter
kg
1.38
g) 25mm diameter
kg
1.37
h) 28mm diameter
kg
1.36
i)
kg
1.36
10mm diameter
kg
1.50
k) 13mm diameter
kg
1.45
l)
16mm diameter
kg
1.40
m) 20mm diameter
kg
1.30
n) 22mm diameter
kg
1.29
o) 25mm diameter
kg
1.28
p) 28mm diameter
kg
1.27
q) 32mm diameter
kg
1.26
r)
40mm diameter
kg
1.26
s) 50mm diameter
kg
1.26
B. REINFORCEMENT
1. Bar Reinforcement
Mild steel bar reinforcement complying with SS 18
32mm diameter
2. Fabric Reinforcement
Welded steel fabric reinforcement complying with SS 32 and well lapped (measured
nett)
a) Reference No A5
m2
5.44
CONTRACT VT297D
FSR/23
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
2
b) Reference No A6
7.13
8.98
d) Reference No A8
11.54
e) Reference No A9
m2
14.41
17.64
g) Reference No B5
10.18
h) Reference No B6
m2
11.56
13.17
17.03
m2
19.90
23.13
m) Reference No B11
26.71
n) Reference No B12
m2
30.77
o) Reference No B13
37.95
p) Reference No D6
13.64
q) Reference No D7
m2
17.36
22.49
s) Reference No D9
m2
28.25
t)
Reference No D10
m2
34.71
u) Reference No D11
41.89
v) Reference No D12
m2
49.73
c) Reference No A7
f)
i)
j)
Reference No A10
Reference No B7
Reference No B8
k) Reference No B9
l)
r)
Reference No B10
Reference No D8
C. PRECAST CONCRETE
1. Kerb or Divider
Precast concrete kerb or divider in Grade 25 concrete including laying in alignment
and finishing fair on all exposed surfaces
a) 125 x 300mm Type K2 Kerb
14.15
16.20
Extra over 125 x 300mm Type K2 Kerb for 125 x 300 x 980mm long, Type K2 Kerb
with scupper mouth
c) generally
No
2.05
2. Cover Slab
Precast concrete Grade 30 cover slab all as detailed in Drawing Nos.
LTA/RD/SD99/DRA/9&10
a) 640 x 270 x 75mm
ISSUE NO: JUNE 2009
No
8.70
CONTRACT VT297D
FSR/24
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
D. FORMWORK
1. Sawn Formwork
Sawn formwork to in-situ concrete including strutting not exceeding 3.5m high
a) curved surface
b) plain surface
m2
32.50
28.20
2. Wrought Formwork
Wrought formwork to in-situ concrete including strutting not exceeding 3.5m high
a) curved surface
b) plain surface
m2
40.40
35.00
m2
3.90
3. Strutting
Extra over for strutting exceeding 3.50m high
a) Every 1.50m high
E. WATER PROOFING TO CONCRETE
1. Damp Proof Membrane
Waterproofing sheet laid to top, side or underside of concrete structure
a) Medium weight (Basic wt: 280g/m2 ) approved building
paper
b) Heavy weight (Basic wt: 527g/m2) approved building
paper
m2
4.50
m2
4.90
2. Water-stops
PVC water-stop embedded in concrete at interfaces of structural elements
a) 200mm wide
23.70
b) 250mm wide
29.00
m2
7.40
a) 12mm thick
4.20
b) 20mm thick
4.50
3. Protection
Polystyrene board fixed to external surface of concrete
a) 25mm thick, 16 kg/m3 grade
F. SUNDRIES
1. Expansion Joints
75mm high bitumen impregnated fibreboard joint filler
CONTRACT VT297D
FSR/25
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
c) 25mm thick
5.70
d) 10mm diameter
2.20
e) 15mm diameter
2.40
f)
2.70
g) 15mm deep
13.50
h) 25mm deep
20.80
25mm diameter
2. Trowelling
Labour trowel top surface of concrete to a smooth finish including additional cement
m2
a) generally
3.30
3. In-situ Kerbs
Concrete kerb finished fair on all exposed surfaces including formwork, angles, ends
and intersections per 1000 mm2 cross sectional area
a) grade 20
0.40
b) grade 25
0.45
c) grade 30
0.50
4. Cutting To Concrete
Labour in cutting reinforced concrete to form groove not exceeding 100mm wide
including rendering with cement mortar (1:3)
a) ne 50mm deep
7.20
b) 50 - 100mm deep
14.20
5. Demolition
Break up existing concrete structure including cutting and bending reinforcement and
removal of debris off site
a) opening ne 0.10 m3
b) opening 0.10 - 0.20m
No
53.70
No
70.90
355.00
CONTRACT VT297D
FSR/26
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
m2
20.50
m2
31.40
59.30
m2
30.50
m2
4.40
m2
23.90
m2
47.80
3. Engineering Brickwork
Engineering brick (standard size 215 x 102.5 x 65mm) complying with BS 3921
Class A with 69 N/mm2 compressive strength in cement mortar (1:4) with mortar
plasticiser
a) Half brick thick wall
m2
69.50
141.00
4. Facing Brickwork
First grade red facing brick (standard size 215 x 102.5 x 65mm) complying with SS
103 in cement mortar (1:4) with mortar plasticiser
a) One brick thick wall, pointed on one side
b) One brick thick wall, pointed on both sides
m2
111.40
114.00
B. CONCRETE BLOCKS
1. Hollow Blockwork
Hollow concrete block complying with SS 76M in cement mortar (1:4) with mortar
plasticiser
a) 75mm thick wall
m2
18.00
CONTRACT VT297D
FSR/27
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
2
19.60
32.00
m2
27.50
2. Vent Blockwork
Precast concrete vent block complying with SS 76M in cement mortar (1:4) with
mortar plasticiser
a) 100mm thick wall
m2
60.40
m2
67.70
m2
27.40
33.10
C. GLASS BLOCKS
1. Walls/Panels
Glass block in wall or panel in cement mortar (1:4) with mortar plasticiser
a) 150 x 150 x 100mm thick
m2
292.00
230.00
D. SUNDRIES
1. Damp Proof Courses
3 ply bituminous felt horizontal damp proof course complying with BS 743 Type B in
cement mortar (1:4) with mortar plasticiser to wall
a) 112.5mm wide
b) 225mm wide
3.40
5.60
2
13.30
7.90
b) 50 - 100mm deep
11.90
CONTRACT VT297D
FSR/28
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
3. Demolition
Break up existing masonry structure including removal of debris off site
a) opening ne 0.10m3 (taking down with care)
No
8.40
No
14.20
m3
30.90
V. ROOFING
A. TILE ROOFING
1. Clay Roof Tiles
Natural tone Marseille profile clay roofing tile complying with SS 70 fixed to battens
(measured separately) with galvanised nails at approximately 400mm centres
m2
42.50
31.60
56.90
No
62.30
e) apex tile
No
122.70
m2
22.50
45.30
m2
60.70
9.40
25.00
31.50
a) generally
Extra over Marseille for roof accessory
B. BUILT-UP ROOFING
1. Felt Roofs
Bituminous felt roofing on flat roof including sealing and bonding
CONTRACT VT297D
FSR/29
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
m2
31.10
m2
34.70
D. RAINWATER GOODS
1. Flashings/Cappings
0.61mm thick galvanised steel standard rainwater goods with zincalume coating and
colorbond finish including fixing clips, bolts and nails
a) 300mm girth flashing
18.30
26.10
2. Gutters
1mm thick galvanised steel open box gutter with zincalume coating and colorbond
finish including brackets, fixing clips, bolts, nails and laying to falls
a) 600mm girth gutter
42.70
76.50
Unplasticised polyvinyl chloride half-round gutter including brackets, fixing clips, bolts,
nails and laying to falls
c) 150mm diameter
32.30
d) 200mm diameter
36.40
3. UPVC Downpipes
Unplasticised polyvinyl chloride rainwater downpipe including solvent welded joints
and jointing to sumps and drains
a) 100mm diameter
11.80
b) 150mm diameter
16.00
No
6.70
No
12.80
No
32.90
f)
No
40.10
No
20.90
No
41.50
CONTRACT VT297D
FSR/30
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
4. Spout Outlets
Rainwater spout outlet with removable cast iron dome grating and luted flange
including jointing to rainwater downpipes and setting in concrete slab to form a
watertight joint
a) 100mm diameter cast iron outlet
No
21.10
No
41.30
m2
6.90
m2
15.80
30.20
33.90
E. SUNDRIES
1. Insulation
Insulation material to roof
Wire mesh to roof space including dressing over purlins (measured net)
a) BRC Reference No 3315 (75 x 75 x 1.5mm diameter)
VI.
m2
4.30
A. STRUCTURAL STEELWORK
1. Mild Steel Members
Mild steel member complying with BS 4360 Grade 43C in stanchion, beam, girder,
roof truss, purlin, cleat and bracket
a) solid section
kg
3.80
b) hollow section
kg
3.90
B. METALWORK
1. Mild Steel Members
Mild steel flat, rod, angle, channel, baluster and rail complying with BS 4360 Grade
43C
a) generally
kg
3.50
CONTRACT VT297D
FSR/31
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
No
1.65
No
2.05
No
12.55
No
1.70
No
2.05
No
12.50
49.10
No
72.00
No
440.00
Set
100.00
Set
210.00
Hot dip galvanised brace support (on one side) including post, spacer, brace with
mild steel plates welded, set in and including concrete foundation, all necessary
excavation, disposal of excavated material as per Drawing Nos. LTA/RD/SD99/VIG/6
to 7
c) 150 150 6mm SHS
Set
350.00
CONTRACT VT297D
FSR/32
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
Set
6,400.00
Set
8,300.00
Set
4,500.00
Design, supply and install redirective and non-gating crash attenuator in compliance
with NCHRP 350 Test level 3 complete with extruding head terminal, post, support,
foundation, W-beam, Thrie beam and all necessary fixings as per Drawing No.
LTA/RD/SD99/VIG/13
d) Crash cushion
Set
34,000.00
Set
4,750.00
D. RAILING
1. Aluminium Alloy Railing
Aluminium alloy railing in powder coating finish consisting of tubular or square hollow
section set in and including concrete foundation, all necessary excavation and
disposal of excavated material from site as per Drawing Nos. LTA/RD/SD99/RAL/1B
- 2B
a) type A
190.00
b) type B
173.00
c) type C
150.00
d) type D
180.00
E. GRATING
1. Pedestrian Grating
Mild steel grating in panels consisting of 80 x 38 x 4.6mm galvanised steel angle
frame, with 35 x 9mm galvanised mild steel flat all round, in filled with 25 x 5mm
galvanised mild steel flat, all joints and intersections whole welded, drilled and
including painting with one coat of inhibitive primer before delivery and built into
concrete surround including 3mm thick galvanised chequer plate cover as per
Drawing Nos. LTA/RD/SD99/GRA/1 to 3
a) generally
m2
258.50
CONTRACT VT297D
FSR/33
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
2. Vehicular Grating
Mild steel grating in panels consisting of 100 x 75 x 9.4mm thick galvanised angle
frame with 65 x 9mm fish-tailed mild steel flat welded at 30mm centres and infilled
with 12mm diameter mild steel bars at 85mm centres, all joints and intersections
whole welded, drilled and including painting with one coat of inhibitive primer before
delivery, built into concrete surround as per Drawing Nos. LTA/RD/SD99/GRA/4 & 5
a) generally
m2
640.00
3. Aluminium Rung
300 x 230mm aluminium rung as per Drawing No. LTA/RD/SD99/DRA/4A fixed to
concrete wall in drain including drilling and grouting with cement mortar (1:3)
a) 25mm diameter
No
18.50
kg
1.10
a) General Surfaces
m2
12.00
1.35
2.00
2.50
F. SURFACE TREATMENT
1. Hot Dip Galvanising
Hot dip galvanising complying with SS 117 to structural steelwork
a) generally
2. Powder Coating Finish
Powder coating finish to metalwork complying with BS 4842
VII.
m2
12.30
b) 20mm thick
m2
13.80
Cement and Sand (1:3) plaster mixed with mortar plasticiser and waterproofing
compound to concrete or brick surface including trowelling smooth
c) 13mm thick
m2
14.20
d) 20mm thick
16.60
CONTRACT VT297D
FSR/34
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
2. Screed Bed
Cement and sand (1:3) screed to concrete or brick surface to receive wall finishes
a) 13mm thick
m2
9.20
b) 20mm thick
m2
10.70
3. Aggregate Plaster
Granite aggregate plaster consisting of cement and granite chippings (1:2) with
mortar plasticiser to concrete or brick surface including scrubbing to produce
exposed aggregate finish
a) 20mm thick
m2
23.90
b) 25mm thick
27.10
m2
11.20
12.20
13.60
4. Plain Paving
Cement and sand (1:3) paving including trowelling smooth
20mm thick cement and sand (1:3) skirting with splayed or rounded top edge and
coved bottom including trowelling smooth
d) 100mm high
4.90
e) 150mm high
5.60
5. Waterproofed Paving
Waterproofed cement and sand (1:3) paving with waterproofing compound including
trowelling smooth
a) average 20mm thick
m2
13.30
m2
14.90
17.10
19.00
m2
22.70
20mm thick cement and sand (1:3) skirting with waterproofing compound including
splayed or rounded top edge and coved bottom and trowelling smooth
f)
100mm high
5.10
g) 150mm high
5.90
6. Hardened Paving
25mm thick cement and sand (1:3) paving mixed with hardener including trowelling
smooth
a) light duty non-metallic hardener (3kg per m2)
m2
16.70
CONTRACT VT297D
FSR/35
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
2
2
22.00
7. Granolithic Paving
Granolithic aggregate paving consisting of cement, sand and granite chippings of
5mm gauge (2:1:5) set out in panels with 15 x 15mm deep recessed joints laterally at
1.20m centres including scrubbing to produce exposed aggregate finish
a) 25mm thick
m2
28.50
b) 32mm thick
32.30
36.50
a) 20mm thick
m2
9.80
b) 25mm thick
10.80
c) 32mm thick
m2
12.20
c) 40mm thick
8. Screed Bed
Cement and sand (1:3) screed to receive floor finishes
B. TILE FINISHES
1. Glazed Tiles
Supply and lay white glazed wall tile complying with SS 301 including pointing with
white cement
a) 5mm thick
m2
60.00
m2
15.80
Supply labour and mortar for laying tiles to floor including painting with white cement
b) generally
m2
15.80
C. PAVING BLOCK
1. Concrete Interlocking Paving Block
Precast concrete interlocking paving block of any pattern including filling joints with
dry and sharp sand and 50mm thick bedding sand
a) 60mm thick
m2
35.30
b) 80mm thick
36.70
c) 100mm thick
m2
38.80
CONTRACT VT297D
FSR/36
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
D. SUNDRIES
1. Hacking Wall Finishes
Hack off existing wall finishes of any thickness including removal of debris off site
m2
4.30
b) tiled finishes
2.80
m2
4.50
a) plaster
5.20
b) tiled finishes
3.30
m2
6.30
a) paving
VIII. PLUMBING
A. SANITARY PIPEWORK
1. UPVC Pipes
Unplasticised polyvinyl chloride soil, waste, ventilating and anti-syphonage pipe
complying with SS 213 including solvent cement joints
a) 32mm diameter
6.50
b) 40mm diameter
7.80
c) 50mm diameter
8.70
d) 80mm diameter
11.50
e) 100mm diameter
12.90
f)
19.10
No
2.30
No
2.70
i)
No
3.30
j)
No
5.70
No
5.90
l)
No
13.90
No
3.20
No
4.60
150mm diameter
CONTRACT VT297D
FSR/37
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
No
5.10
No
8.00
No
9.50
r)
No
29.80
No
3.40
t)
No
4.00
No
7.30
No
10.00
No
14.80
15.90
b) 20mm diameter
20.20
c) 25mm diameter
25.00
d) 32mm diameter
32.50
e) 40mm diameter
37.20
f)
50mm diameter
39.70
g) 65mm diameter
53.80
h) 80mm diameter
72.00
No
4.00
j)
No
4.20
No
5.30
l)
No
7.40
No
10.60
No
11.80
No
20.80
No
30.10
No
6.50
r)
No
6.80
No
8.30
t)
No
10.60
CONTRACT VT297D
FSR/38
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
No
11.10
No
15.40
No
19.00
No
27.00
No
6.70
No
7.00
No
10.10
No
10.50
No
14.00
No
22.00
48.40
b) 100mm diameter
56.10
c) 150mm diameter
73.10
No
41.40
No
52.00
f)
No
72.40
No
52.90
No
63.90
i)
No
101.00
j)
No
40.30
No
62.60
No
13.20
b) 20mm diameter
No
23.60
c) 25mm diameter
No
57.70
d) 32mm diameter
No
62.90
CONTRACT VT297D
FSR/39
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
e) 40mm diameter
No
88.70
f)
50mm diameter
No
144.20
g) 65mm diameter
No
194.90
a) 65mm diameter
No
129.10
b) 80mm diameter
No
172.10
a) 80mm diameter
No
147.20
b) 100mm diameter
No
166.00
c) 150mm diameter
No
304.90
m2
5.80
m2
4.00
5.10
m2
6.30
m2
8.40
m2
10.00
m2
10.60
2. Gate Valves
Brass gate valve complying with BS 5154 including wheel handle
3. Sluice Valves
Cast iron sluice valve complying with BS 5163
IX.
PAINTING
A. PAINTING
1. Concrete or Plastered Surfaces
Painting concrete or plastered surface and the like
a) one coat of oil based anti-alkali sealer, one undercoat
and two finishing coat of acrylic emulsion paint
2. Timber Surfaces
Painting timber surface
a) two coats of aluminium wood primer
3. Metal Surfaces
Painting metal surface
CONTRACT VT297D
FSR/40
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
4. Weldmesh Surfaces
Painting on both sides of weld-mesh (measured flat on one side)
a) one coat of anti-rust paint, one undercoat and two coats
of aluminium paint
m2
6.80
m2
7.60
1.70
b) large pipe
3.00
2.00
b) large pipe
3.70
7. Road Marking
One coat of 1.5mm thick thermoplastic paint on road pavement as per Drawing No.
LTA/RD/SD99/RMS1&2
a) 100mm wide line
1.90
2.80
3.70
5.60
2
13.20
One coat of 3.0mm thick thermoplastic paint on road pavement as per Drawing Nos.
LTA/RD/SD99/RMS/1 to 3
f)
6.50
8.50
m2
24.70
i)
go-straight arrow
No
44.00
j)
No
50.60
No
39.80
l)
No
36.70
merge arrow
Erase existing thermoplastic road lines and markings including clearing all shavings
and making good
CONTRACT VT297D
FSR/41
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
2
m) generally
X.
15.00
DRAINAGE WORK
A. DRAINAGE WORK
1. Drain Excavation
Excavate trench minimum 340mm wide for 100mm diameter pipe, not exceeding
2.00m deep including backfilling and disposal of surplus excavated material
a) average 600mm deep
10.40
17.30
33.30
Excavate trench minimum 490mm wide for 150mm diameter pipe including
temporary supports, backfilling and disposal of surplus excavated material
d) ne 2.00m deep, average 1.50m deep
36.30
56.30
40.00
17.60
b) 150mm diameter
29.10
m3
95.20
m2
7.70
2. Filling Materials
a) Graded stone 19mm size
3. Drainage Layer
a) Geocomposite drainage layer as per Drawing Nos.
LTA/RD/SD99/DRA/2, 4A, 5A & 6A
CONTRACT VT297D
FSR/42
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
60.80
b) 450mm diameter
88.60
c) 600mm diameter
126.80
d) 750mm diameter
194.40
e) 900mm diameter
246.50
f)
1050mm diameter
291.00
g) 1200mm diameter
352.50
h) 1350mm diameter
427.40
i)
1500mm diameter
534.60
j)
1800mm diameter
786.70
Precast concrete pipe culverts Class 'M' complying with SS 183 butt jointed with
cement and sand (1:1) mortar
k) 300mm diameter
68.70
l)
450mm diameter
101.50
m) 600mm diameter
143.10
n) 750mm diameter
199.30
o) 900mm diameter
295.00
p) 1050mm diameter
342.60
q) 1200mm diameter
437.20
r)
1350mm diameter
515.20
s) 1500mm diameter
618.30
t)
884.80
1800mm diameter
143.50
b) 750 x 600mm
165.00
c) 900 x 600mm
201.70
CONTRACT VT297D
FSR/43
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
d) 1000 x 600mm
258.30
e) 1200 x 600mm
291.10
2. Composite Channels
Precast concrete composite channel or block drains laid to even falls and jointed in
cement and sand (1:3) mortar
a) Type C1
6.70
b) Type C2
7.00
c) Type C3
8.90
d) Type C4
9.70
e) Type C5
11.40
f)
11.00
g) Type C6
15.20
h) Type C7
23.70
i)
Type C7A
20.40
j)
Type C7B
16.80
k) Type C8A
60.30
l)
62.30
m) Type B1
19.50
n) Type B2
25.60
o) Type B3
68.00
Type C5A
Type C8B
Precast concrete channel laid in precast 'U' drain base sections or precast concrete
culverts including concrete grade 20 benching
p) Type C5A
18.30
26.50
24.00
56.00
No
1.10
3.60
c)
No
1.20
4.20
4. Weepholes
Supply and fix UPVC pipe to SS213 as weephole
CONTRACT VT297D
FSR/44
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
E. SUNDRIES
1. Drop Inlet Chamber
Precast concrete drop inlet chamber including hot dip galvanised mild steel framing
and grating laid on compacted sub-base and including forming proper connection to
scupper pipe as per Drawing No. LTA/RD/SD99/DRA/7C
a) 750 x 275 x 325mm Internal size
No
180.00
2. Sump
Precast concrete sump for sub-soil drain including proper connections, concrete
benching and precast concrete cover slabs, internal size
a) 550 x 550 x 1300mm
XI.
No
339.00
m3
60.30
A. PAVEMENT
1. Sub-base
Sub-base material
a) generally
2. Base Course
Coarse granite aggregate (crusher-run) base course and blinded with fine aggregate
a) generally
m3
102.50
m3
107.50
95.00
b) mix-specification type W1
95.00
c) mix-specification type W3
95.00
Supply and lay hot-mix asphalt concrete base course mix-specification type B1
d) 75mm (consolidated) thick
m2
16.75
20.10
26.80
f)
CONTRACT VT297D
FSR/45
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
Supply and lay hot-mix asphalt concrete wearing course mix-specification type
W3/W1
g) 25mm (consolidated) thick
m2
5.60
8.95
11.20
i)
4. Sundries
Brush, sweep and thoroughly clean to remove all loose and superfluous materials
and ensure a perfectly dry surface prior to the application of the tack coat and
asphalt concrete
a) existing bitumen or concrete surfaces
XII.
m2
0.10
A. FENCING
1. Chain Link Fences
50mm x 50mm mesh 8 SWG PVC coated galvanised steel chain link fencing
complete with 50 x 50 x 6mm thick mild steel angle post spaced at approximately
3.00m centres, and bedded into and including 300 x 300 x 675mm deep concrete
(grade 15) base including straining fittings and running three strands of 6 SWG PVC
coated galvanised straining wires between posts and four strands of pvc coated
galvanised barbed wires along top of fencing including painting mild steel fence
posts with one coat of red lead primer, one undercoat and two finishing coats of
enamel paint, excavation for concrete base, formwork and disposal of excavated
materials from site
a) 2150mm high overall fence with 2500mm long post
60.00
No
142.80
CONTRACT VT297D
FSR/46
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
No
68.50
B. STREET FURNITURE
1. Directional Signs
Single-face directional signs comprising aluminium sheeting 14SWG laminated with
approved reflective sheeting including all the required size of letters, numbers, logo(s)
and all necessary backings, welding and other types of connections as per Drawing
Nos. LTA/RD/SD99/SUP/1A-3A (supports to be measured separately)
a) High Intensity Grade
b) Micro Prismatic Reflective Grade
m2
494.00
602.00
No
400.00
No
2,800.00
No
3,400.00
f)
No
3,700.00
2. Traffic Signs
Single-faced silk screen traffic signs as regulatory signs, warning signs and
informative signs comprising 2mm thick aluminium sheets, approved Micro Prismatic
Grade reflective sheetings including appropriate diagrams, alphabets and numerals
(supports to be measured separately)
a) size 600 x 450mm
No
160.00
No
197.00
No
305.00
CONTRACT VT297D
FSR/47
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
No
92.00
C. SUNDRIES
1. Turfing
Turfing consisting of grass, size 300 x 300mm not less than 50mm thick, including
50mm thick topsoil and sludge (3:1) top dressing
a) spot turf on horizontal surface
m2
4.90
m2
6.10
24.20
29.00
10.50
6.50
34.40
f)
40.40
14.70
8.50
3. Geotextile Membrane
Approved synthetic geotextile fabric membrane to troughs, french drains etc. well
lapped at joint (measured nett)
a) Type Class B
m2
2.80
CONTRACT VT297D
FSR/48
ITEM DESCRIPTION
UNIT
RATE ($)
______________________________________________________________________________________________________________
No
370.00
5. Paving Slabs
Precast concrete (grade 20) paving slab jointed and pointed in cement and sand (1:3)
including 50mm thick sand bed
a) size 300 x 300 x 50mm thick
m2
41.50
6. Aeration Slabs
Precast concrete aeration slab of any pattern with top soil and turfing in voids
including 50mm thick sand bed
a) 65mm thick
b) 100mm thick
m2
35.00
41.00
CONTRACT VT297D