This is the list of fixed timers with a brief explanation and their values. A timer expiry message
appears in its own window, on the test set display. The user has no access to these values and
can not change them. None of the fixed timers are active when operating mode is Test Mode.
Timer Name
Description
Value
T100 RADIOLINK-TIMEOUT
4 SACCH
multiframes. That is
1.92 seconds if the
SACCH is
completely absent.
T301 Alerting
(ringing) timer
20 seconds
T303 Mobility
Management
connection timer
T305 Release
timer
T308 Release
timer
T310 Call
proceeding timer
10 seconds
10 seconds
10 seconds
T313 Connect
Time the network waits after transmitting a CONNECT
acknowledge timer message until receiving the CONNECT ACKNOWLEDGE
Timer Name
Description
Value
T323 Modify
complete timer
T3103 Handover
timer
T3105 Physical
information
repetition timer
T3107 Channel
assignment timer
1 second
50 ms
3 seconds
T3109 Signalling
disconnection
timer
5 seconds
T3111 Channel
deactivation after
disconnection
timer
500 ms
T3113 Paging
timer
T3212 Location
The location update timer is set to zero, periodic location zero = infinite time
Timer Name
Description
Value
update timer
T3250 TMSI
reallocation timer
T3260
Authentication
response timer
5 seconds