INSPIRATION & DESIGN
Whats new
Acoustical Mini Site
Project Gallery
Video Library
PRODUCTS
SUSTAINABLE DESIGN
TECHNICAL DATA
SUPPORT
By Material
By Market Segment
Environmental Commitment
Environmental Focus
Data Sheets
Order Samples
Order Literature
FAQs
Installation & Maintenance
Test Reports
Warranty
About Armstrong
Find your Armstrong Rep
Contact Techline Expert
Find a Distributor
Find a Branch
Premium
Performance
Designer
Ultima. . . . . . . . . . . . . . . . . . . . . . 58
Dune. . . . . . . . . . . . . . . . . . . . . . .76
Ultima Planks. . . . . . . . . . . . . . . . 60
Fine Fissured. . . . . . . . . . . . . . . . 78
Visual. . . . . . . . . . . . . . . . . . . . . . 90
Optra . . . . . . . . . . . . . . . . . . . . . . 62
Classic Lite. . . . . . . . . . . . . . . . . . 80
Contrast. . . . . . . . . . . . . . . . . . . . 92
Cirrus. . . . . . . . . . . . . . . . . . . . . . 64
Standard
Dune Planks. . . . . . . . . . . . . . . . . 94
Dune Max. . . . . . . . . . . . . . . . . . . 66
Classic. . . . . . . . . . . . . . . . . . . . . 82
Special Areas
ANF . . . . . . . . . . . . . . . . . . . . . . . 84
Bioguard . . . . . . . . . . . . . . . . . . . 96
Classic Max . . . . . . . . . . . . . . . . . 70
Beauti-Sky. . . . . . . . . . . . . . . . . . 86
HealthZone Basic . . . . . . . . . . . . . 98
Suprema. . . . . . . . . . . . . . . . . . . . 72
Minatuff. . . . . . . . . . . . . . . . . . . . 74
Ceramaguard . . . . . . . . . . . . . . . 102
Techzone . . . . . . . . . . . . . . . . . . 104
WoodWorks Ceilings
WoodWorks . . . . . . . . . . . . . . . . 108
MetalWorks
Vector. . . . . . . . . . . . . . . . . . . . . 124
Planks . . . . . . . . . . . . . . . . . . . . 126
Linear. . . . . . . . . . . . . . . . . . . . . 128
Baffles . . . . . . . . . . . . . . . . . . . . 136
Lay-In. . . . . . . . . . . . . . . . . . . . . 122
Cellio . . . . . . . . . . . . . . . . . . . . . 130
Infusions . . . . . . . . . . . . . . . . . . 144
Wall Panels
Optra . . . . . . . . . . . . . . . . . . . . . 146
WoodWorks . . . . . . . . . . . . . . . . 148
Suspension Systems
Introduction . . . . . . . . . . . . . . . . 150
Silhouette . . . . . . . . . . . . . . . . . . 158
Installation . . . . . . . . . . . . . . . . . 164
Axiom . . . . . . . . . . . . . . . . . . . . . 152
Select . . . . . . . . . . . . . . . . . . . . . 159
Bandraster . . . . . . . . . . . . . . . . . 155
Prelude . . . . . . . . . . . . . . . . . . . . 156
Suprafine . . . . . . . . . . . . . . . . . . 157
Cradle
ENVIRONMENT
Grave
EASE OF USE
CONCEPTION
MAINTENANCE
INSTALLATION
Ultima/Suprema
Optra
Ultima
Ultima Planks
Optra
Suprema
Cirrus
Optra Colours
Black
Nile
Blue
Steel
Grey
Amber
Dune
Cirrus
Contrast Circles
Contrast Square
Graphis
Linear
Graphis
Puntos
Graphis
Cuadros
Classic Max
Classic Lite
Classic
Dune Max
Designer
Dune
Fine Fissured
Fine Fissured Hi-NRC
Fine Fissured
Other
Minatuff
ANF
Beauti Sky
Special Areas
Bioguard Acoustic
Open Cell
Bioguard Plain
HealthZone Basic
Ceramaguard
Clean Room FL
(Mylar)
US Maple
Wood Veneers
Maple
Maple
WoodWorks Linear
Natural Variations (Real Wood Veneers)
Beech
Maple
Light Cherry
Dark Cherry
Dark
Bamboo
Maple
Patina
Cherry
Walnut
Native
Metal
Vector
Clip-in
Lay-in
Planks
Curved
Linear
3
2
Cellio
Baffles
Mesh
Woven Wire
Twin
Round
Narrow
Twin
Flat
Narrow
Triple
Narrow
1- Extra Microperforated
2- Microperforated
3- Standard Perforated
available on request.
Expanded Metal
Cascades Lattice
Flat
Linen
Web
SoundScape
Shapes
Infusions
Traffic
White
Pale
Green
Traffic
Grey
Light
Ivory
Pastel
Blue
Pale
Brown
Channeled Chalk
Fire
Folio
Silver
Orbit
Ivory
Autumn
orange
Pista green
Straw gold
Black
Blue
Beige
Rust
Mocha
Woven Scrim
White
Grey
Perimeter Solutions
Knife edge
Classic
Profiled
Prelude
Suprafine
Axiom
Suspension Systems
Bandraster
Silhouette
Select
PRODUCT SELECTOR
Cradle
ENVIRONMENT
Grave
EASE OF USE
CONCEPTION
MAINTENANCE
INSTALLATION
Planks
Visible grid
Bevelled Tegular
(15 mm steel angle)
Tegular
(24 mm steel angle)
Board
(24 mm steel angle)
Bevelled Tegular
(15 mm steel angle)
Board
(24 mm steel angle)
SL2
K2C2
Suprema
Optra
Ultima Planks
Optra
Cirrus
Cirrus
Contrast
Dune
Dune
Dune Max
Dune Planks
Designer
Graphis
Fine Fissured
Fine Fissure
Hi-NRC
Fine Fissured
Standard
Classic Max
Classic Lite
Classic
Minatuff
ANF
Beauti-Sky
Special Areas
Bioguard Acoustic
Bioguard Plain
HealthZone Basic
Ceramaguard
(Mylar)
Open Cell
Visual
Visual
Clean Room FL
Planks
Visible grid
Bevelled Tegular
Tegular
Board
Vector
(15 mm steel angle) (24 mm steel angle) (24 mm steel angle) (24 mm steel angle)
SL2
Concealed
Clip-in
(3 mm)
Clip-in
(3 mm)
Carrier
WoodWorks
Plain
Perforated
Extra microperforated
Microperforated
Perforated
Plain
*Cellio
*Cellio is Board Edge, but
MetalWorks
Suspension Systems
Prelude
Board
Silhouette
Bevelled Tegular
Prelude
Tegular
Select
Bevelled Tegular
Prelude
Vector/SL2
Suprafine
Bevelled Tegular
Bandraster 50/100/150mm
PRODUCT SELECTOR
ENVIRONMENT
Cradle
Grave
EASE OF USE
CONCEPTION
MAINTENANCE
INSTALLATION
Fire
ance
orm
perf 32)
ic
t
p.
us
Aco (see
n
actio
re
H)
(% R
)
e (%
ance
t
c
l
is
n
s
a
re
obia
y
ility
lect
idity
ualit
micr
nab
t ref
Hum
Clea
Anti
Air q
Ligh
4)
tanc
Scra
esis
ch r
(
e
dex
ent
tanc
ice in
r
cont
p
d
tive
ycle
Rec
Rela
Impa
sis
ct re
Mineral /
Soft Fibre
aw
Absorption Attenuation
Ultima/Suprema
Ultima
Cls0/Cls1
Ultima Planks
Cls0/Cls1
Suprema
Class B
up to .70(H)
0.60(H)
0.70
37
@ 88
99
wipeable
BioBlock+
62%
```
0.65
37
@ 90
95
wipeable
BioBlock+
75%
```
0.60
35
@ 88
99
wipeable
BioBlock+
42%
```
@ 83
95
Inherent
66%
```
Optra
Optra
Cls0/Cls1
Class B
0.90
0.90
26
0.90
26
```
Cirrus
Cirrus
A2-s1,d0
0.70(H)
0.70
up to 38
@ 85
95
Contrast
A2-s1,d0
0.55
0.50
36
@ 80
95
BioBlock+
86%
``
33%
```
Dune
Dune
Cls0/Cls1
up to 0.60
up to 0.55
33
@ 85
99
BioBlock+
32%
``
Dune Max
Cls0/Cls1
0.68
0.70
33
@ 85
99
BioBlock+
63%
``
Graphis
A2-s2,d0
0.15(L)
0.15
36
90
70
with drycloth
47%
```
Cls0/Cls1
0.70(H)
0.70
33
@ 85
99
BioBlock+
54%
``
Cls0/Cls1
0.55(H)
0.60
33
@ 84
99
BioBlock+
31%
``
Classic Max
Cls0/Cls1
0.70(H)
0.70
33
@ 87
99
BioBlock+
60%
``
Classic Lite
Cls0/Cls1
0.50
30
@ 84
95
BioBlock+
30%
Classic
BS1,d0,t0
0.55
30
@ 85
99
41%
ANF
Cls0/Cls1
0.50
30
@ 85
90
34%
Beauti-Sky
Cls0/Cls1
0.50
30
@ 80
70
28%
Minatuff
Cls0/Cls1
0.60
33
@ 88
99
40%
``
0.70
0.15
@ 90
@ 90
@ 88
@ 79
95
95
99
95
washable
washable
with dry cloth
washable
Anti-bacterial
Anti-bacterial
BioBlock+
Inherent
62%
34%
34%
35%
```
```
```
```
@ 85
100
Scrubbable
Inherent
34%
```
@ 70
46%
```
Designer
Fine Fissured
Fine Fissured
Hi-NRC
Fine Fissured
Others
Special Areas
Bioguard Acoustic
Bioguard Plain
HealthZone Basic
Clean Room FL
(Mylar)
Ceramaguard
Cls0/Cls1
Cls0/Cls1
Class A2
A2-s1,d0
0.60(H)
0.15(L)
0.10(L)
0.10
37
35
30
35
A1
0.55(MH)
0.60
39
ISO 5
ISO 5
Open Cell
Visual A2-s1,d0 up to 0.95(H) up to 0.90
WoodWorks
Plain
Class 1
up to 75
70
```
Perforation R3
Class 1
0.25(LM)
0.45
up to 75
70
```
Perforation R6
Class 1
0.15(LM)
0.30
up to 75
70
```
PRODUCT SELECTOR
Fire
n
actio
re
H)
(% R
)
e (%
ance
t
c
l
is
n
s
a
re
obia
y
ility
lect
idity
ualit
micr
nab
t ref
Hum
Clea
Anti
Air q
Ligh
ance
orm
perf 32)
ic
t
p.
us
Aco (see
tanc
Scra
esis
ch r
x (4
e
ent
inde
tanc
cont
price
led
e
c
y
iv
c
t
Re
Rela
Impa
sis
ct re
`
aw
NRC
Dncw (dB)
0.55(L)
0.75
0.70(L)
0.65
0.80
0.70
30
20
20
76
63
68
100
100
100
wipeable
wipeable
wipeable
Inherent
Inherent
Inherent
Plain A2-s1,d0
0.10(L)
0.10
44
77
100
high pressure
water cleaning (2)
Inherent
up to 0.95
up to 0.90
@ 95
wipeable
Inherent
MetalWorks
Cellio A2-s2,d0
Group1 Baffles AS/NZS
1530.3
Fire
Building Regulations (where applicable) require that buildings
meet appropriate Euroclass and UK standards for fire reaction
performance depending on the area of application.
ISO 3 (3)
25-50%
25-50%
25-50%
```
```
```
25-50%
```
50%
```
Air Quality
Armstrong offers specific solutions to limit the number of airborn
particules in a clean room environment. These products are tested
against ISO 14644-1.
Acoustics
The occupant of a space, be it an office, a classroom, a shop, or
any similar environment needs:
- Intelligibility to hear and to be understood
- Privacy to not be overheard
- Concentration to not be disturbed.
The optimum acoustic climate will be obtained with the right combination of
sound absorption and sound insulation, and can be supplemented by the use
of active acoustics.
Impact resistance
Frequent ceiling tile removal, typically in areas where building
service equipment is located, means that a higher level of impact
resistance can be desired. In this category, the level of durability and impact
resistance has been improved by Armstrong.
Light Reflectance
Light reflectance of a surface is its property of reflecting light. The
measure of light reflectance is that fraction of the specified incident
light which is reflected by the surface expressed as a percentage value.
Recycled Content
A significant proportion of our products are produced using
particular recycled raw materials. They are indicated in our literature
in accordance with LEED requirements.
Humidity resistance
Ceiling installations are facing more and more demanding
humidity conditions such as: fast track programmes, buildings with
intermittent heating and cooling, areas with a high concentration of people,
structures which are open to the exterior environment, etc.
To meet these requirements Armstrong offers a wide range of products
suitable for installation in conditions of up to 99% Relative Humidity, some of
which excel in extreme conditions of up to 100% RH.
Cleanability
The frequency and method of cleaning of a ceiling varies from one
application to another, from cloth to high pressure water jet and
including resistance to disinfectants for healthcare premises.
See cleaning & maintenance details for full details.
Anti-microbial performance
The control of bio-contamination is essential in the healthcare
sector, especially in hospitals and clinics.
Armstrong ceilings are treated with BioBlock+TM and do not favour the
development of fungi/mould or yeast and the products can be used in any
general area. The Armstrong Bioguard paint reduces the colony size of
virulent strains of bacteria, moulds and yeasts. This special paint finish can be
cleaned and disinfected.
Scratch Resistance
Superior level of surface scratch resistance, evaluated with the
Hess rake test.
10 year warranty
Armstrong World Industries warrants the Armstrong 90% RH products
shall be free from sag* as a direct result of defects in materials or factory
workmanship for 10 years from the date of installation of the material subject to terms
and conditions, when used with Armstrong steel angles.
warranty
15 year warranty
Armstrong World Industries warrants the Armstrong 95% RH products
shall be free from sag* as a direct result of defects in materials or factory
workmanship for 15 years from the date of installation of the material subject to terms
and conditions, when used with Armstrong steel angles.
warranty
30 year warranty
warranty Armstrong World Industries warrants the Armstrong 99% and 100% RH
products shall be free from sag* as a direct result of defects in materials or
factory workmanship for the life time of the product subject to terms and conditions,
when used with Armstrong steel angles.
* N.B. Maximum sag as defined in EN 13964.
ENVIRONMENT
Cradle
Grave
EASE OF USE
CONCEPTION
MAINTENANCE
INSTALLATION
Reception
Terrace Roofing,
Areas
Semi-Exterior Showrooms,
Applications
Lounges
Shops
Individual /
Partitioned
Offices
Prestige
Offices
Rooms,
Consulting
Rooms
Treatment
Rooms
Patient
Rooms
Circulation &
Traffic Areas,
Corridors
Classrooms
Business
Centre,
Waiting Rooms,
Call Centres Meeting Rooms
INDUSTRY
RETAIL AND LEISURE
TRANSPORT
HEALTHCARE
EDUCATION
OFFICE
Suprema
Optra
Optra
Optra Colours
Cirrus
Cirrus
Contrast
Dune
Dune
Dune Max
Designer
Graphis
Open Cell
Visual
Fine Fissured
Fine Fissured Hi-NRC
Fine Fissured
Other
Classic Max
Classic Lite
Classic
Minatuff
ANF
Beauti-Sky
Special Areas
Bioguard Acoustic
Bioguard Plain
HealthZone Basic
Clean Room FL (Mylar)
Ceramaguard
WoodWorks
Ceilings
Wall Panels
Linear
Metal
Extra Microperforated (2)
Microperforated (2)
Perforated (2)
Plain
Baffles
10
SoundScapes Canopies
SoundScapes Shapes
Infusions
Lecture
Theatres,
Libraries,
Languages
Rooms
Restaurants,
Cafeterias,
Bars, Canteens
Kitchens
Humid Areas,
Specific Areas, Sports Rooms,
Toilets,
Computer
Cloakrooms
Rooms
Swimming
Pools
Food
Departments
Theatres,
Cinemas,
Auditoria
Super
markets
Department
Stores
Luxury
Boutiques
Operating
theatres
Laboratories
INDUSTRY
RETAIL AND LEISURE
TRANSPORT
HEALTHCARE
EDUCATION
OFFICE
Suprema
Optra
Optra
Cirrus
Cirrus
Contrast
Dune
Dune
Dune Max
Designer
Graphis
Open Cell
Visual
Fine Fissured
Fine Fissured Hi-NRC
Fine Fissured
Other
Classic Max
Classic Lite
Classic
Minatuff
ANF
Beauti-Sky
Special Areas
Bioguard Acoustic
Bioguard Plain
HealthZone Basic
Clean Room FL (Mylar)
Ceramaguard
WoodWorks
Ceilings
Wall Panels
Linear
Metal
Extra Microperforated *
Microperforated *
Perforated *
Plain
Baffles
SoundScapes Canopies
Infusions
*For perforated metal, recommendations are based on a product with factory fitted acoustic fleece.
11
PRODUCT SELECTOR
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
Mineral Wool
Natural Starch
Perlite
Clay
Recycled Paper
Recycled Tiles
superior resistance
to rust and corrosion.
Damage-resistant ceilings
- Scrubbability
- Washability
- Soil resistance
- Impact & scratch resistance
- Bioguard products provide
additional resistance to a large
selection of bacteriological
strains.
5. WARRANTY ON USE
A history of quality products.
Long term warranties on ceilings
systems.
3. INSTALLATION
Integrate technology to reduce
installation time.
Minimal packing material used.
Up to 100% of the packaging
is made from recycled material.
In several countries, we support
the recollection of packaging.
4. MAINTENANCE
2. PRODUCTION
All in-process scrap is recycled
back into the process.
Almost all the process water
is recycled. Only a minimal
amount of water is discharged,
and only after proper treatment.
LEED
The Leadership in Energy and
Environmental Design (LEED) Green
Building Rating System encourages
and accelerates global adoption
of sustainable green building and
development practices through
the creation and implementation of
universally understood and accepted
12
13
ENVIRONMENT
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
14
Criterion 13
Supporting
Clause
Points that
can be earned
17.3.1
Acceptable
outdoor & indoor
noise levels
29.3.2
Optimise building
design to reduce
conventional
energy demand
13.2.3 : Over
design of
lighting system
is avoided
Use low-energy
material in
interiors
ENVIRONMENT
Criterion 29
Description
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
Our Commitment
A global leader in the building materials
industry, Armstrong is committed to
environmental sustainability. We fulfill
this commitment by systematically
reducing the environmental footprint
of our operations and by providing
products and services to our customers
that enable you to reduce the
environmental impact of the buildings
you create.
Our Actions
Our Policy on the Environment
articulates the operating fundamentals
that support our commitment to
sustainable growth. We have selected
four Environmental Priorities to reduce
our environmental footprint: Energy,
Greenhouse Gases, Water, and
Responsible Forest Management.
Key Requirements:
Our policy on the environment is:
To exercise care in the selection and
use of energy and raw materials.
To provide for environmental safety in
our work places and communities.
To be prepared for emergencies and
to act promptly and responsibly to
protect people and the environment.
To ensure all products conform to
safety, environmental and quality
standards.
To reduce waste and embrace
recycling in all of our operations and
to dispose of waste materials in an
environmentally responsible manner.
51%
LEED Credits
Energy
16
Daylight
& Views
Ultima tiles
17
ENVIRONMENT
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
18
buildings are.
LEED Credits
High light reflectance ceilings can also
contribute to LEED points, especially in
the Energy and Atmosphere category
under EA Credit 1.0 (Optimize Energy
Performance). In the Brinjac study, for
example, energy points were achieved
by nothing more than increasing the
light reflectance.
Based on the spaces used in the study,
the reduction in total building energy
consumption as defined by LEED NC
2.2 could be as high as 10.6% when
optimizing the lighting layout with 90%
reflective ceilings. This savings
qualifies for 1 point in a new building or
3 points in an existing building.
Hi-LR ceilings are also a factor in the
Indoor Environmental Quality category
by contributing to EQ Credit 8.1, 8.2
(Daylight and Views). This is because
high light reflectance ceilings can
extend natural daylighting into a
space. And, Hi-LR ceiling systems
can contribute in the Materials and
Resources category in the following
areas:
MR Credit 2.1, 2.2 (Construction Waste
Management),
MR Credit 4.1, 4.2 (Recycled Content),
MR Credit 5.1,
5.2 (Local/Regional Materials), and
MR Credit 6.0
(Rapidly Renewable Materials).
Seeing the Light
As indicated by the Brinjac study,
architects and designers should look
at the ceiling system as an integral
element of a buildings energy reduction
strategy. The overall cost impact
compared to potential energy savings
make high light reflectance ceilings a
viable solution for achieving energy
reductions without the need for more
costly new technology.
ENVIRONMENT
TEST RESULTS
TEST RESULTS
Cost in /m2 (Europe data)
* Cost = luminaires + installation + cables
Light reflectance
SOIL RESISTANCE
The simulated supply air diffuser soiling test evaluates this soil-resistant property.
TEST RESULTS
TEST
DirtRESULTS
accumulation not only detracts from
Typical ceiling
ceilings appearance,
but can
cost
money
Dirtaaccumulation
not only detracts
from
a ceilings
by
requiring
painting
or
replacement
of
appearance, but can cost money by requiring
the
ceiling.
In
addition
to
reducing
acoustical
painting or replacement of the ceiling. In addition
efficiency,
soiling can
causesoiling
a substantial
to reducing
acoustical
efficiency,
can cause
reductionreduction
in light reflectance.
Ultima Ultima
provides
a substantial
in light reflectance.
excellent
soil
resistance
for
lasting
value
provides excellent soil resistance for lasting value and
and performance.
performance.
Ultima
SCRUBBABILITY TEST
EST RESULTS
TESTT RESULTS
Typical ceiling
These
photos
show
the excellent
These
photos
show the
excellent
scrubbability
scrubbability
ofceiling.
Ultima vs a typical ceiling.
of Ultima
vs a typical
Ultima
19
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
20
State of Washington
and EPA 50 ppb.
50
40
30
20
Section 01350
CHPS 13.5 ppb.
10
0
No Added
Formaldehyde
Low
Formaldehyde
California Office
of Environmental
Health Hazard
Assessment 2.5 ppb.
21
ENVIRONMENT
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
22
construction process.
Fortunately, while mold can grow on
virtually any surface, the use of proper
building design, construction and
maintenance practices can mitigate the
possibility of excessive mold growth.
The relationship between mold
exposure in buildings and human health
is currently the subject of medical
study. Exposure to most kinds of
mold usually has no effect on healthy
individuals. However, exposure to
certain kinds of molds may cause
discomfort, cause or aggravate
allergies and asthmatic conditions, and
increase the risk of respiratory illness
or infections in susceptible or allergic
individuals. Because of this, conditions
that foster mold growth in an indoor
environment should not be allowed to
develop or persist.
The Construction Process
Before construction
When designing the building envelope,
systems that not only shed water but
also are capable of drying out if water
does penetrate them are required to
help keep moisture from infiltrating the
building.
On the interior, HVAC systems that
provide proper ventilation and air
exchange are required to help prevent
the creation of high humidity conditions
and possible condensation. There
is no substitute for good building
design, construction and maintenance
practices for preventing mold growth.
Enhanced mold resistance, however,
can be achieved through the selection
of specially treated products for use in
a buildings interior. Armstrong ceilings,
for example, can be treated with two
different types of antimicrobials:
BioBlock Ceilings treated with
BioBlock inhibit or retard the growth
of mold on the painted surface
when used in accordance with good
design, construction and maintenance
practices. The BioBlock formulation
contains a fungicide that is applied to
During construction
If building materials are kept dry prior
to installation, the risk of mold growth
is significantly reduced. Therefore,
contractors should have a plan for
protecting materials from water
damage, paying particular attention to
the way the materials are transported
and unloaded, and then stored at the
construction site.
To preclude the growth of mold, it is
important to keep the building interior
dry during construction. For example,
if contractors must install interior
finishes before the building envelope is
enclosed or before the HVAC system
is in operation because of a fast track
construction schedule, it is important
to cover the area in which they are
working to shut out the weather and
help ensure that condensation and
other forms of moisture are not trapped
in the building.
If the area is enclosed, contractors
can use desiccant dehumidifiers or
indirect-fired heaters to dry areas where
they are installing or applying certain
finishes, particularly if water is visible
in those areas. Humidity control firms
can also create a temporary humidity
and temperature control system
using similar equipment. If moisture is
introduced during a wet construction
process, such as wet concrete and
masonry, poured flooring, or painting, it
is important to maintain an ample level
of ventilation to insure proper drying.
NOTE: Armstrong HumiGuard sagresistant ceilings can be installed in
high humidity conditions, but not
in the presence of condensation.
Condensation allows moisture to come
in direct contact with the ceiling. This
can lead to possible mold growth
and also void the product warranty.
After Construction
Building operation and maintenance are
no less important than building design
and construction in ensuring moisture
control. As buildings become tighter,
the amount of air exchanged between
the interiors conditioned spaces and
the outdoors diminishes, resulting in
significantly less dilution of moisture.
Consequently, provisions must be
made to provide proper ventilation.
Otherwise, moisture will take longer to
migrate out of the building, increasing
interior relative humidity, creating a
higher likelihood of condensation
and reducing the drying potential.
Regular inspection and maintenance
of the building envelope and interior
spaces is also critical. Caulked joints
are particularly important because, if
ignored, leaks around windows, doors,
roofs and foundations can become
serious problems. On the interior, make
sure the water used in cleaning and
other maintenance procedures does
not find its way into enclosed spaces
or soak finished materials. In addition,
owners and their maintenance crews
must try to avoid any accumulation
of water in any location where water
should not be. This includes such
conditions as a cracked water pipe or
an overflowing toilet. In these cases,
the water event must be immediately
addressed. It also includes less obvious
conditions such as condensation on
windows, doors, pipes, drains or
mechanical systems, all of which can
provide enough moisture for mold to
begin to grow. Regardless of the cause,
the presence of any unwanted water in
a building must be prevented.
Taking action
If a facility is shut down for an extended
period of time, such as a school over
summer vacation, it is important that
the HVAC system continues to operate.
Failure to do may cause moist, humid
conditions and condensation that could
lead to the growth of mold.
If mold is found, it is important to
immediately identify the cause of the
23
ENVIRONMENT
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
ACOUSTICAL COMFORT
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
24
At any listeners position. the sound level contribution can be analysed as follows
Sound Level
Signal: "What we
want to understand"
Natural voice
Amplified voice
Music
Background noise:
"What we do not
want to hear"
Intrusive noise
- Break-in noise such as road/air
traffic
- Mechanical noise (HVAC)
Occupational noise
-
Computer fans
Phones ringing
Copying machines
Distant people's voices
Occupant behaviour (open window
for air temperature control)
RECEPTION OF A SOUND
EMISSION OF A SOUND
ACOUSTICAL COMFORT
The search for optimum acoustical conditions can be summarised under Intelligibility, Confidentiality
and Concentration. Its all about the right difference between signal and background noise, the
so-called Signal-to-Noise ratio. The following table shows some examples of spaces with the most
important criteria to focus on.
Intelligibility
Confidentiality
Open space
Call centre
Closed office
Classroom
area
Hospital bedroom
Retail shop
Library
Hospital waiting
ACOUSTICS
Conference room
Concentration
25
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
ACOUSTICAL COMFORT
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
Suspended ceiling systems play a key role in the control of the acoustical environment thanks
to their important surface and modularity.
Ceiling tiles provide a combination of sound absorption, attenuation and reduction:
Sound absorption is the part of
incident sound that is not reflected
by the tile.
4
1
26
2
3
ABSORPTION ATTENUATION
1
2
3
4
1-2
REDUCTION
Incident sound
Reflected sound
Transmitted sound
Absorbed sound
Sound absorption
Sound absorption
Sound absorption
Intelligibility
Room occupants
Room neighbours
Microperforated metal
with fleece
Density
Porosity
Thickness
Controls
Effect upon
Benefits
ACOUSTICAL COMFORT
The table below shows examples of spaces with the most appropriate type of mineral density and some product
suggestions.
High Density
Open space
Call centre
Closed
office
Library
Cirrus
WoodWorks Ceilings and
Wall Panels
Ultima, Suprema,
Dune Max, Dune,
Fine Fissured Hi-NRC,
Classic Max
Cirrus
Optra,
Metal Microperforated,
Optra Wall Panels
Optra
Hospital
waiting area
Hospital
bedroom
Low Density
ACOUSTICS
Classroom
Conference
room
Medium Density
Bioguard Plain,
Metal Plain
Retail shop
Metal Plain,
WoodWorks Wall Panels
Optra,
WoodWorks Ceilings and
Chanelled WoodWorks Panels
Retail bank
agency
WoodWorks Perforated
Optra,
Metal Microperforated,
Optra Wall Panels
27
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
ACOUSTICAL COMFORT
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
NEW BUILD
Project design
RENOVATION / RETROFIT
Project commissioning
28
Implementation
System support
8 months
12 / 18 months
Programming
MAINTENANCE
ACOUSTICAL COMFORT
PASSIVE ACOUSTICS
WEIGHTED SOUND ABSORPTION
COEFFICIENT,
Dncw
ACOUSTICS
ACTIVE ACOUSTICS*
/ VOICE ALARM
MUSIC
PUBLIC ADDRESS
SOUND FIELD
SOUND MASKING
MUSIC MASKING
29
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
ACOUSTICAL COMFORT
VISUAL
COMFORT
Acoustical performance
WELL BEING
ENVIRONMENT
Cradle
Grave
NRC
125
250
500
1000
2000
0.70(H)
0.70
0.55
0.50
0.65
0.80
0.90
0.85
0.35
0.60
0.40
0.35
0.55
0.80
0.70
0.70
4000
Optra Tiles 25 mm
1.00
0.90
0.50
0.85
1.00
0.95
1.00
1.00
Optra Tiles 20 mm
0.95
0.90
0.40
0.80
1.00
0.85
1.00
1.00
Optra Tiles 15 mm
0.90
0.90
0.35
0.75
1.00
0.80
0.90
0.95
Cirrus Tiles 19 mm
0.70(H)
0.70
0.35
0.40
0.45
0.55
0.60
0.70
0.70
0.70
0.50
0.55
0.75
0.75
0.70
0.45
0.65(H)
0.70
0.55
0.56
0.69
0.90
0.78
0.61
FF Hi NRC Tiles
0.70(H)
0.70
0.30
0.40
0.70
0.90
0.85
0.85
0.60
0.50
0.35
0.45
0.60
0.65
0.55
0.45
0.60
0.50
0.50
0.45
0.60
0.65
0.60
0.50
Dune Tiles
0.55(H)
0.60
0.37
0.33
0.49
0.76
0.78
0.65
0.55(H)
0.60
0.37
0.33
0.49
0.76
0.78
0.65
0.55
0.50
0.49
0.35
0.50
0.67
0.63
0.45
0.15(L)
0.15
0.35
0.20
0.10
0.10
0.15
0.25
0.95
0.90
0.35
0.80
0.95
0.90
1.00
1.00
0.50(H)
0.50
0.10
0.30
0.40
0.50
0.75
0.90
0.55
0.50
0.40
0.40
0.45
0.55
0.60
0.65
0.15(L)
0.15
0.30
0.20
0.15
0.10
0.20
0.25
0.10(L)
0.10
0.25
0.15
0.10
0.10
0.10
0.15
Ceramaguard Tiles
0.55(H)
0.60
0.25
0.30
0.50
0.80
0.85
0.75
*fg: Fibreglass quilt **ap: Termed practical sound absorption coefficient, is calculated for the octave bands at 250, 500, 1000, 2000 and 4000Hz, from the one-third octave band
measurements of sound absorption. 1) All tests have been conducted in an independent third party quality assured laboratory in accordance with EN ISO 354 and with the ceiling installed
over a 200 mm cavity. 2) aw & NRC values are determined in accordance with EN ISO 11654 & ASTM C423 respectively. 3) Armstrong conducts extensive and regular acoustic tests on
its ceiling tiles and planks. Inevitably slight variations occur over a range of results for the same product. The results above do not necessarily represent the highest achieved but indicate
values that can be consistently and confidently offered. 4) #Tested at Sound Research Laboratories, U.K./NVLAP certified laboratories.
30
ACOUSTICAL COMFORT
Sound attenuation
Product Name
100
125
160
200
250
315
400
500
630
800
44
20.8
27.6
28.9
33.4
37.0
34.1
32.3
37.8
48.0
50.6
49.7
53.1
53.0
51.5
51.4
48.8
48.9
48.8
41
17.0
25.6
29.7
29.3
32.9
32.6
31.2
35.5
42.2
44.9
46.3
49.4
51.0
50.5
50.1
47.8
48.0
48.3
41
15.1
25.2
26.9
29.8
31.6
31.7
31.3
35.5
41.6
47.0
48.7
51.2
52.5
52.3
51.5
49.3
49.4
49.1
39
15.0
24.9
26.7
29.2
29.6
30.4
29.2
33.4
39.3
43.2
45.8
48.8
50.9
51.0
51.3
49.1
49.4
48.7
Ultima Tiles
36
15.6
24.9
27.7
27.6
28.3
27.2
27.0
28.8
31.4
35.6
37.8
40.1
43.3
45.5
49.4
49.7
46.4
54.5
Cirrus Tiles 19 mm
35
17.6
20.9
24.9
25.9
26.9
28.4
27.8
29.3
32.3
35.2
37.8
40.2
43.5
47.3
49.4
51.4
54.3
56.4
33
13.8
22.9
25.1
27.2
28.0
26.9
25.9
27.3
32.0
34.9
38.6
41.3
45.0
47.4
47.9
46.1
46.5
46.9
36
15.4
23.5
25.1
28.8
29.9
30.3
29.8
30.9
34.0
35.8
37.6
39.4
39.8
39.9
40.1
39.2
39.0
40.4
36
17.4
23.1
23.2
25.9
27.2
28.0
28.0
29.3
32.5
35.7
38.5
40.8
42.1
42.6
43.0
41.3
41.5
42.4
37
13.3
23.2
25.8
28.2
29.4
29.4
28.3
30.6
34.2
37.9
39.1
41.2
42.8
44.0
44.0
44.2
45.3
43.9
36
13.6
24.4
26.4
28.2
29.9
28.7
29.3
31.3
34.4
36.1
37.3
39.3
40.2
40.1
39.5
37.4
35.8
36.7
Ceramaguard Tiles
39
16.1
24.6
27.2
29.5
30.4
29.9
30.4
32.5
38.8
43.2
44.8
46.9
48.6
48.7
48.1
46.3
44.0
46.1
32
20.0
21.4
22.2
22.9
21.6
23.6
26.9
29.0
32.9
35.4
40.3
43.2
45.2
45.9
45.6
46.7
35
24.0
24.0
26.0
27.0
25.0
27.0
31.0
33.0
36.0
39.0
42.0
46.0
50.0
51.0
52.0
53.0
35
27.8
27.5
27.6
28.2
25.5
27.0
29.3
30.8
34.5
36.7
42.4
45.7
49.6
52.5
55.2
56.7
ACOUSTICS
Dncw
31
ACOUSTICAL
COMFORT
VISUAL
COMFORT
Cradle
AIR QUALITY
Classification
number ISO
0,2 m
0,3 m
0,5 m
Class ISO 1
10
Class ISO 2
100
24
10
Class ISO 3
1 000
237
102
35
1 m
ENVIRONMENT
5 m
-
Class ISO 4
10 000
2 370
1 020
352
83
Class ISO 5
100 000
23 700
10 200
3 520
832
Class ISO 6
1 000 000
237 000
102 000
Class ISO 7
Class 1
Class 10
29
Class 100
35 200
8 320
293
Class 1 000
352 000
83 200
2 930
Class 10 000
Class ISO 8
3 520 000
832 000
29 300
Class ISO 9
35 200 000
8 320 000
293 000
32
Grave
WELL BEING
BIOGUARD
Typical ceiling
Bioguard
Typical ceiling
Typical ceiling
Bioguard
Salmonella typhimurium
Staphylococcus aureus
Listeria monocytogenes
Bacillus subtilis
Saccaromyces cerevisiae
Candida albicans
Aspergillus niger
Trichderma harzianum
The Anti-microbial
performance can be
identified by this icon.
Bioguard combines a high level of
particle cleanliness and anti-microbial
performance. It has successfully
passed the very stringent French
norm for hospitals, NF S 90-351, met
the HTM recommendations for the
Washability
This is an ASTM D-4828 test. The washability test evaluates a ceilings ability
to withstand washing. The test uses the washing action of a sponge and a non
abrasive soap. This test measures a ceiling surfaces resistance to repeated wash
cycles. Ratings are based on either the ability of the surface to withstand up
to 500 wash cycles without breakthrough, or the extent of abrasion.
Stain resistance
This test uses 3 familiar liquids: tea, coffee and cola. The test demonstrates the
ceiling surfaces excellent resistance to staining. Several drops of the staining liquid
are applied to the surface. After 30-60 seconds the surface is wiped with a damp
cloth. The stained area is rated a 1 for no visible stain to a 5 for severely stained.
Water repellency
This test demonstrates the ceiling surfaces resistance to water penetration.
Several drops of water are applied to the surface. The shape of the water
droplet demonstrates how well the surface repels the water and resists water
penetration.
The frequency and method of cleaning of a ceiling varies from one application to another. All products can at least be
cleaned with a dry cloth or vacuum cleaner.
Wipeable with a moist cloth.
33
Bioguard
ACOUSTICAL
COMFORT
SAFE &
HEALTHY
VISUAL
COMFORT
Cradle
WELL BEING
ENVIRONMENT
Grave
REACTION TO FIRE
34
Circulation areas
Other Rooms (> 30 m )
2
Euroclass
Non-combustible
A1
Limited Combustibility
A2-s3, d2
Class 0
B-s3, d2
Class 1
Class 2
C-s3, d2
Class 3
D-s3, d2
Class 4
E-s2, F
35
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
PRODUCTS
STORAGE
INSTALLATION
36
NO
35
35
YES
120 120
Cross
tee
x 120 120
INSTALLATION
Hanger
10 cm min.
Main runner
5 - Installation of Tiles
a - Engage the tiles into the steel angle
by lifting them diagonally upwards
through the steel angle before being
laid down onto the steel angle flanges.
NB: Vector edged tiles are only engaged
from below the steel angle.
10 cm min.
X
X
X
X
X
X
X
1,20 1,20 1,20 1,20 1,20 1,20 1,20
X
X
X
X
X
X
X
X
X
X
X
X
X
X
10 cm min.
X
X
40 cm
Hole
Perimeter
cut tile
Full tile
3 - Installation of Hangers
Establish the location of the top fixings
(1200 x 1200 mm centres) and fix with
regard to the soffit material and load
to be carried. Engage the threaded
rod into the top fixing and with bottom
nuts ready to receive the suspension
clip. Alternatively use Quick-Hangers/
hanger wire with top and bottom rods
bent over.
Distance between
main runner
37
Cradle
Tile installation
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
6
4
5
3
2
1
1 Main runner
0.84 LM/m2
0.84 LM/m2
1.67 LM/m2
1.67 LM/m2
0.84 LM/m2
MATERIAL
4 Hanger
5 Perimeter trim
0.7 unit
0.7 unit
NB: For SL2, because of the variable length of the steel angles and their use in directional buildings, quantities to be installed vary and have to
be estimated for each jobsite.
38
PLANK INSTALLATION
Installation and maintenance
Board, Tegular
(Prelude)
1 - Main runner
2 - Long cross tee
3 - Hanger
4 - Perimeter trim
5 - Plank
ma
x4
00
ca
20
30
31 0/
2.5
30
31 0/
2.5
25
/1
0
20
0/
35
1
0/
80
/1
0
50
30
31 0/
2.5
L=
30
31 0/
2.5
*Specific MicroLook
cross tee needs to
be specified to fit with
slotted Bandraster.
Please contact Internal
Technical Sales for
complete information.
ca
20
3
31 00/
2.5
3
31 00/
2.5
3
31 00/
2.5
1 - Bandraster
2 - Splice
3 - Long cross tee
4 - Nonius hanger
5 - Perimeter trim
6 - Wall connector
7 - Plank
INSTALLATION
13
50/
12
00/
3
31 00/
2.5
180
00/
15
50/
3
31 00/
2.5
12
L=
39
PLANK INSTALLATION
Installation and maintenance
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
Semi-concealed SL2/K2C2
(Prelude 24, Main runners
or Bandraster)
1 - Main runner
2 - Cross Tee
3 - Stabiliser bar
4 - Hanger wire
5 - Wall molding
6 - Plank
Semi-concealed SL2/K2C2
(Bandraster)
1 - Bandraster
2 - 24 mm main runner/cross tee/C-channels
3 - Spacer bar
4 - Nonius hanger
5 - Threaded Rod dia. 6 mm
6 - Perimeter trim
7 - Plank
40
SL2
Peakform T- grid
17mm
9mm
11.5mm
1.5mm
13mm
26mm
Step 1:
Step 4:
Uniform
300mm
or less
1200 mm
or less
Step 3:
1200 mm
or less
300mm
or less
Staggered
1200mm
or less
300mm
or less
300mm
or less
INSTALLATION
Step 2:
Decide on location of carrier bar
1. general spacing between 2 carrier
bars should be at distances not
*For external applications, the spacing between carrier bars should not exceed 600 mm
41
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
Step 1:
Step 4:
Step 2:
Suspend to ceiling using rigid means
such as threaded rods or galvanized
steel sections (channel/angle etc.)
GI angle/Channel/
Threaded rod for suspension
Step 5:
To install Clip-in tiles, engage the pips
on the tiles on to the clip-like end of
the secondary steel angle sections
(DP12 carrier) by applying positive
upward pressure.
C Channel
C Channel
connector
300/600/1200 mm
DP12
Carrier
Step 3:
Connect longer pieces of primary
steel angle sections using splices
(C-Channel connector)
42
Spacer Bar
Prelude 38/43
Peakform
main runner
1500 mm max.
600 mm
12 mm
C-Channel Hanger
C-Channel
T-Bar
Suspension
Clip
43
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
Optra acoustical wall systems are easy to install over existing walls or directly to studs with minimal workplace disruption.
Standard installation method is with impalers. J or Z splines can be used to create an exposed system
Optra Wall Panels can also be affixed to the wall using superior quality construction adhesive, as follows:
1. Sand the wall surface to remove surface imperfections/loose particles to enable greater bonding of the adhesive
2. Clean the wall of dust. Apply a coat of primer and allow to dry
3. Mark the location of each panel on the wall
4. Apply silicon caulk or a similar adhesive/sealant using a gun-dispenser on the back of the panel and on the wall
5. Carefully align the wall panels against the marked locations on the wall and press the panel against the wall till it is fixed
tightly. Remove excess adhesive.
44
INSTALLATION
45
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
Connection Details
END CAP
UNIGRID CHANNEL
BAFFLE HANGER
LOCKING CLIP
BAFFLE
BAFFLE
BAFFLE JOINER
(ALIGNMENT ONLY)
Section Views
5mm ROD
SUSPENSION CLIP
BAFFLE HANGER
1200mm (max)
400mm (max)
LOCKING
CLIP
30
LOCKING CLIP
137
BAFFLE
UNIGRID CHANNEL
ENDCAP
5mm ROD
UNIGRID CHANNEL
100
BAFFLE JOINER
WITH FIXING ECREWS
25
25
187
150
SUSPENSION CLIP
BAFFLE HANGER
UNIGRID CHANNEL
LOCKING CLIPS
BAFFLE
ENDCAP
Preparation
1. Determine desired height of ceiling.
2. Strike a level line around the
perimeter of the area at this height.
3. Determine direction of linear ceiling.
4. The carriers will be installed 1200
mm on center perpendicular to this
direction. The first and last carrier
must be within 600mm of the wall.
Installation
1. Install the standard Carrier Wall
Molding on the perimeter walls.
Molding is nominal 50mm high and
should be secured to wall every
400 to 600 mm. The bottom of the
molding is the finished height of the
linear panel.
40 x 40mm
Angle Molding
(7805)
Ceiling Plane
Carrier
Guide string
to cut and align carrier
for border panel
600mm
600mm
600mm
600mm
600mm
600mm
MetalWorks Linear
plank direction
Linear Carrier
location
40mm x 40mm
Angle Molding
(7805)
INSTALLATION
150mm
150mm
Linear Carriers
spaced 600mm O.C.
Wall
47
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
Preparation
Determine desired height of new
ceiling. Strike a level line around the
perimeter of the area to indicate the
height of the top of the molding to
be installed. Determine the desired
direction of the ceiling.
Installation
1 If the installation is to run from wall
to wall, install wall molding on a level
line around the perimeter of the area.
Allow 6mm for the natural expansion
and contraction of wood every
2440mm of length at the moldings
or by introducing expansion areas
within the ceiling field.
40 x 40mm
Angle Molding
(7805)
19mm Reveal
Factory-applied Linear Clip
Linear Plank
Ceiling Plane
Wall
Linear Carriers
spaced 610mm O.C.
610mm
610mm
610mm
610mm
610mm
610mm
Linear Splic
150mm
150mm
Linear Wood
plank direction
Linear Plank
Linear Plank
Linear Carrier
location
40mm x 40mm
Angle Molding
(7805)
Linear Fleece
610mm
Linear Carriers
48
Wall
Factory-applied
Linear Clip
Guide String
Linear Plank
Perimeter Treatment
When the installation is not slated to
run from wall to wall, cut the ends of
the planks before installing and paint
or edge band exposed ends. Stain or
edge band the cut ends of the planks.
The first and last carriers must be no
more than 100mm from the sides of
the floating installation.
For detailed installation instructions, please refer to
the specific installation manual.
Preparation
Infusions Canopy Panel Kit
Contents:
1. Flat Infusions Panel - 1 or 2 nos.
2. Cables to form arcs
Arc
60
1475mm
1770mm
90
1400mm
1670mm
Arc
1220 X 3050mm
30
3050mm
50
2980mm
Center Access
Standard Suspension
Installation Kits
Standard 2440mm Hanging Kit
7004 and 4880/9100mm Hanging Kit
- 7005/7010
Gripper
Structure
Anchor
or Side B on
Graphix panels
1. Thread
Cable
Through
Gripper
Adjuster
3. Adjust
accordingly
Gripper
Adjuster
2440mm
Cable
2. Screw
Gripper
Adjuster
into the
Gripper
Structure
Anchor
Tensioning
Suspension
Accessories
Kit Contents:
Gripper Structure Anchors 2 Nos
Gripper Adjusters 2 Nos
Suspension Cables (2440mm)
NOTE: Cables must not exit the
Gripper Adjusters at an angle. The
maximum allowable deflection is 5.
Substitute Kit 7005 or 7010 when
cables meet the structure at an angle.
INSTALLATION
49
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
Spiral Anchor
Plan View
1220mm
suspension
points
gripper
structure
anchor
610mm
1181mm
Hill
4880mm cable
Valley
gripper
bottom end
assembly
hook
50
1870mm
Spiral anchor
gripper
anchor cap
gripper
bottom end
cable adjuster
Aircraft Cable
Cable attaches to
panel below via
the Bottom End
Cable Adjuster
Bottom End
Cable Adjuster
Corner Bracket
1219mm
Panel Hook
1.27mm x 9.5mm Bolt
attaches to 1.27mm square nut
inside back-channel
Back-channel
marked at center and 200mm O.C.
to assist with hook placement
51mm
x = panel hook locations during installation
= recommended hanging point location
51
INSTALLATION
51mm
1219mm
Gripper Structure
Anchor
355mm
355mm
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
52
CLEANING
TYPE OF PAINT
PRECAUTIONS
INSTALLATION
53
SERVICE INTEGRATION
Cradle
ENVIRONMENT
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
A - Pattress
B - Ceiling Tile
C - Steel angle Profile
D - Downlighter
E - Smoke Detector
Notes:
- The above details are only indicative. It is the responsibility of the specifier or contractor to ensure that the fittings
can be supported without damage or excessive deflection of the tiles and steel angle.
- A pattress may be formed from gypsum board or similar thin rigid sheet. It is essential to ensure that the material
chosen has a fire reaction performance equivalent to that of the reverse face of the ceiling tile.
54
SERVICE INTEGRATION
1. The linear/modular lighting is a continuous (independently supported) lighting trough located between areas of
modular ceiling steel angle. Alongside the edge of each trough are main runners that form the boundary of the modular
ceiling which will be comprised of either tiles or planks.
2. The linear lighting is a continuous (independently supported) lighting trough located between areas of modular ceiling
steel angle. The edges of each trough are turned out so as to form a ledge upon which the ceiling system, comprised of
tiles or planks, is supported. SL2 planks may be able to span between the lighting troughs without the aid of intermediate
support. With this system spacer bars or similar ties will be needed to ensure that the spacing between parallel troughs
is maintained.
INSTALLATION
Notes:
The above details are only indicative. It is the
responsibility of the specifier or installer to ensure
that the lighting fittings are compatible with the
ceiling system and that the fittings can be supported
onto the steel angle without damage or excessive
deflection.
55
SERVICE INTEGRATION
ENVIRONMENT
Cradle
Grave
EASE OF USE
MAINTENANCE
CONCEPTION
INSTALLATION
BULKHEADS (UPSTANDS)
(Please also refer to the Axiom and Trulok brochure
for additional details)
PARTITION CONNECTIONS
Notes:
- Partitions which are subject to horizontal static or
dynamic loads may require additional bracing. This
may be achieved (as shown in the above detail) by
using steel angles which are mechanically fixed
to the steel angle section and then secured to a
suitable point of structure above. The angle formed
between the bracing and the horizontal plane should
not be greater than 45degrees. Two bracing angles
are normally required to provide opposing lateral
restraint.
- Further details may be obtained from the Partition
manufacturer and contractor.
56
PERIMETER TREATMENTS
Section
'L' Angle
19
19
'L' Angle
32
1) Board (site cut or full tile) for Ceramaguard used in 100% RH areas and other applications
using corrosion resistant steel angle
2) Metal Clip-in tiles
19
Shadowline
19
7
7
1) Bevelled Tegular (site cut square) on Silhouette steel angle with cross tee
supported by perimeter trim
2) Vector (site cut square) for Ultima wet-felt or Optra soft tiles with
cross tee supported by perimeter upper ledge
14
INSTALLATION
57
ULTIMA RH99
Board & tiles
Ultima RH 99 is a high performance
Armstrong product which meets the most
demanding requirements by combining
excellent sound absorption, sound
attenuation, high light reflectance,
good humidity resistance and superior
durability. Additionally, with its patented
"DURABRITE TM" surface, Ultimas
elegant design makes it ideal for todays
requirements.
Ultima
Ultima
58
ne
mi
ra
l
b
r
oa
&
tile
62%
LEED Credits
s
im
ult
99
rh
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
ULTIMA RH 99
BOARD
TEGULAR
Prelude XL 24 mm
BEVELLED TEGULAR
Prelude XL 24 mm
Suprafine 15 mm/
Silhouette
5mm
9.5mm
19mm
8mm
19mm
3mm
8mm
19mm
Hz
NRC 125 250
Board/Tegular/Bevelled Tegular
0.70(H)
0.70 0.55 0.50
Vector
0.70(H)
0.70 0.35 0.40
aW
EN 20354
& EN 11654
0.80
0.90 0.85 a p
0.70
0.90
0.90 0.85 a p
Board/Tegular/Bevelled Tegular
Dncw = 37 dB
EN 20140-9
& EN 717-1
@ 88%
99% RH
@ 5.2 kgs/m
59
Recycled
Content
ULTIMA RH 95
Planks
Modern commercial construction
often has a requirement to reflect
the building module into the ceiling
design, allowing flexible segmentation
of the interior.
In combination with the existing
attributes of Ultima, Ultima planks
provide a solution for this demand,
as well as being suitable for use
in corridors.
Ultima
60
75%
LEED Credits
ne
mi
ra
n
pla
ks
im
ult
95
rh
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL2/TL 24 mm
Prelude XL 24 mm
Suprafine 15 mm/
Silhouette
ULTIMA PLANKS RH 95
19mm
8mm
19mm
3mm
8mm
K2C2
12mm
5mm
9.5mm
SL2
9mm
11.5mm
19mm
13mm
2mm
17mm
19mm
17mm
9.5mm
19mm
26mm
Hz
aW
NRC
125
250
0.65(H)
0.65
0.35
0.45
0.60
0.75
0.85 0.90 a p
EN 20354
& EN 11654
EN 20140-9
& EN 717-1
Board
Dncw = 37 dB
K2C2/SL2
Dncw = 38 dB
@ 90%
95% RH
@ 5.2 kgs/m
61
Recycled
Content
OPTRA RH 95
Tiles & Planks
Optra is a glass fibre ceiling solution for
high acoustic spaces with glass fibre
(Optra FG) and rockwool (Optra RW) as
core material.
The ideal product for modern office
environments, its excellent sound absorption properties (high NRC of 0.9
up to 1.0) helps in creating noise free
open plan offices, cafeterias, or any
other places where too much noise can
be disruptive. This improves comfort
and increases productivity by reducing
ambient noise.
Optra
Black
Steel Grey
Nile Blue
Amber
Optra
62
ne
mi
ra
s
tile
&
n
pla
LEED Credits
ks
o
95
rh
ra
pt
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
OPTRA RH 95
BOARD
TEGULAR
BEVELLED TEGULAR
SL2/K2C2
Prelude 24 mm
Prelude 24 mm
Suprafine 15 mm/
Silhouette
XL 24 mm
4.5mm
9.5mm
15/20/25mm
8mm
15/20/25mm
8mm
9mm
15/20/25mm
13mm
12mm
17mm
11.5mm
2mm
20/25mm
17mm
20/25mm
9.5mm
26mm
Optra FG Classic,
Pebble and Pearl
600 x 600 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 600 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1800 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2400 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1800 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2400 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2700 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1200 x 1200 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optra FG Classic Black
600 x 600 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1800 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2400 x 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1800 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2400 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2700 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1200 x 1200 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optra FG Colour: White, Black (standard)
Steel Grey, Nile Blue, Amber (on request)
1.2
Hz
aW
EN 20354
& EN 11654
NRC
125
250
0.80
0.92 1.00 a P
0.88
1.08 1.00 a P
@ 85%
1.16
95% RH
1.1
1.0
0.9
0.8
0.7
0.6
125
250
500
1000
2000
4000
63
Recycled
Content
CIRRUS RH 95
Board & Tiles
Cirrus tiles provide a warm, smooth
textured visual along with good
acoustical properties and a range
of edge details particularly suited
to the designer range of steel angle
systems.
Cirrus
Cirrus
64
ne
mi
ra
l
b
r
oa
&
tile
86%
LEED Credits
s
ru
cir
95
rh
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
CIRRUS RH 95
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
Suprafine 15 mm/
Silhouette
4.5mm
9.5mm
19mm
8mm
19mm
3mm
8mm
19mm
aW
0.70(H)
Hz
NRC
0.70
125
0.55
250
0.50
EN 20354
& EN 11654
EEA
Euroclass A2-s1, d0
CH
RUS
In 1 (NBK 14)
@ 85%
95% RH
@ 4.0 kgs/m2
65
Recycled
Content
DUNE MAX RH 99
Tiles & Planks
Dune Max, the new 20mm tile offers
a high sound absorption (NRC0.70) suitable for open office spaces
especially.
The new improved texture also displays
less visible perforations on the surface.
The sag performance has also been
improved to RH 99 thereby increasing
the service life of the tile.
Dune Max can now help you build
Dune Max
Dune Max
66
ne
mi
ra
l
b
r
oa
&
tile
s
d
e
un
rh
ax
63%
LEED Credits
99
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
Suprafine 15 mm/
Silhouette
9.5mm
20mm
20mm
SL2
4.5mm
8mm
K2C2
9mm
20mm
11.5mm
13mm
M=6.5mm
D =7.5mm
17mm
12mm
19mm
2mm
17mm
9.5mm
19mm
26mm
aW
0.60
Hz
NRC
0.70
125
0.40
250
0.45
EN 20354
& EN 11654
CAC = 33 dB
EN 20140-9
& EN 717-1
@ 85%
99% RH
@ 4.16 kgs/m2
67
Recycled
Content
Fine Fissured
Hi-NRC
68
ne
mi
ra
l
b
r
oa
&
tile
54%
LEED Credits
d
re 99
su
fis rc rh
e
fin hi-n
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
Suprafine XL 15 mm
Silhouette
4.5mm
9.5mm
20mm
8mm 20mm
8mm
20mm
aW
0.70 (H)
Hz
NRC
0.7
125
0.30
250
0.40
EN 20354
& EN 11654
CAC = 33 dB
EN 20140-9
& EN 717-1
@ 85%
99% RH
@ 4.4 kgs/m2
69
Recycled
Content
Classic Max
Classic Max
70
ne
mi
ra
l
b
r
oa
&
tile
s
s
cla
sic
x
ma
rh
60%
LEED Credits
99
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
CLASSIC MAX RH 99
BOARD
TEGULAR
XL 24 mm
XL 24 mm
BEVELLED TEGULAR
XL 15 mm/
Silhouette
4.5mm
9.5mm
17mm
8mm 17mm
8mm
17mm
aW
0.70 (H)
NRC
0.7
125
0.58
Hz
250
0.57
EN 20354
& EN 11654
@ 87%
99% RH
@ 4.2 kgs/m2
71
Recycled
Content
SUPREMA RH 99
Suprema
Suprema
72
ne
mi
ra
l
b
r
oa
&
tile
s
s
r
up
h
a r
em
42%
LEED Credits
99
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
SUPREMA RH 99
BOARD
XL 24 mm
TEGULAR
BEVELLED TEGULAR
XL 24 mm
XL 15 mm/
Silhouette
5mm
9.5mm
16mm
8mm 16mm
8mm
16mm
aW
0.60 (H)
NRC
0.6
125
0.38
Hz
250
0.34
EN 20354
& EN 11654
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
125
250
500
1000
2000
4000
CAC = 35 dB
EN 20140-9
& EN 717-1
@ 88%
99% RH
@ 3.9 kgs/m2
73
Recycled
Content
MINATUFF RH 99
Medium Texture
Minatuff is a product that combines
high impact resistance and light
reflectance. Its non-directional visual
reduces installation time and wastage,
while the good light reflectance allows
for more effective use of energy. This
product is formulated to withstand
conditions where temperature reaches
up to 49C and relative humidity up to
99%.
Minatuff
Minatuff
74
ne
mi
ra
l
b
r
oa
&
tile
s
m
h
f r
tuf
ina
40%
LEED Credits
99
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
MINATUFF RH 99
TEGULAR
BEVELLED TEGULAR
XL 24 mm
XL 15 mm/
Silhouette
9.5mm
7mm
5mm
16mm
8mm
16mm
aW
0.60
Hz
NRC
0.60
125
0.35
250
0.33
4000
0.45 a P
EN 20354
& EN 11654
CAC = 33 dB
88%
99% RH
3.6 kgs/m2
75
Recycled
Content
DUNE RH 99
Board & tiles
The Dune family features a microperforated, finely granulated surface
texture and is available in a wide
variety of size and edge details. Dune
will allow you to find a solution to your
requirements whatever your technical
constraints.
The Dune range offers improved
durability and enhanced acoustical
absorption.
Dune
Dune
76
ne
mi
ra
l
b
r
oa
&
tile
32%
LEED Credits
s
d
e
un
99
rh
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
DUNE RH99
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
Prelude XL 15 mm
Silhouette
9.5mm
16mm
5mm
8mm 16mm
3mm
8mm
16mm
aW
0.60
Hz
NRC
0.50
125
0.35
250
0.40
EN 20354
& EN 11654
CAC = 33 dB
EN 20140-9
& EN 717-1
@ 85%
99% RH
@ 3.9 kgs/m2
77
Recycled
Content
FINE F ISSURE D RH 99
Tiles & Planks
The non-directional Fine Fissured
surface is designed for effective sound
absorption. The SecondLook option
allows the supporting suspension
system to be integrated into the ceiling
pattern.
Fine Fissured
Fine Fissured
78
ne
mi
ra
s
tile
&
n
pla
ks
f
ine
fis
e
ur
rh
31%
LEED Credits
99
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
FINE FISSURED RH 99
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
Suprafine 15 mm/
Silhouette
9.5mm
16mm
16mm
SL2
12mm
4.5 mm
8mm
K2C2
9mm
16mm
M=6.5mm
D =7.5mm
11.5mm
13mm
2mm
17mm
19mm
17mm
9.5mm
19mm
26mm
aW
0.55(H)
NRC
0.60
125
0.37
250
0.33
Hz
500 1000 2000 4000
0.49 0.76 0.78 0.65 a P
EN 20354
& EN 11654
CAC = 33 dB
EN 20140-9
& EN 717-1
@ 85% (white)
99% RH
Board/Bevelled
Tegular/Tegular
@ 3.5 kgs/m2
SL2/K2C2
@ 4.5 kgs/m2
79
Recycled
Content
Classic Lite
Classic Lite
80
ne
mi
ra
l
b
r
oa
&
tile
s
s
cla
sic
lite
rh
30%
LEED Credits
99
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
CLASSIC LITE RH 99
BOARD
TEGULAR
XL 24 mm
BEVELLED TEGULAR
XL 24 mm
9.5mm
16mm
7mm
XL 15 mm/
Silhouette
5mm
16mm
8mm
16mm
NRC = 0.50
CAC = 30 dB
87%
99% RH
3.1 kgs/m2
81
Recycled
Content
CLAS SIC RH 90
Board & tiles
The non-directional visual reduces
both installation time and wastage,
while providing the perfect blend of
acoustical performance and light
reflectance, ideal for retail, healthcare,
offices and conference rooms,
corridors, classrooms and utility areas
in schools.
Classic
Classic
82
ne
mi
ra
l
b
r
oa
&
tile
s
s
cla
sic
41%
LEED Credits
90
rh
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
CLASSIC RH 90
BOARD
TEGULAR
BEVELLED TEGULAR
XL 24 mm
XL 24 mm
XL 15 mm/
Silhouette
9.5mm
15mm
8mm 15mm
NRC = 0.55
EN 20354
& EN 11654
CAC = 30 dB
EN 20140-9
& EN 717-1
l = 0.26 W/mK
@ 85%
90% RH
@ 3.0 kgs/m2
83
Recycled
Content
ANF RH 90
Board & tiles
ANF is a high light reflectance product.
Its non-directional visual reduces
installation time and wastage. It is
economical, easy to install, with
relatively low maintenance. This
product is formulated to withstand
conditions where temperature reaches
up to 49C and relative humidity up to
90%.
ANF
ANF
84
ne
mi
ra
l
b
r
oa
&
tile
34%
LEED Credits
s
a
rh
nf
90
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
ANF RH 90
BOARD
TEGULAR
XL 24 mm
BEVELLED TEGULAR
XL 24 mm
9.5mm
15mm
7mm
Suprafine XL 15 mm/
Silhouette
5mm
15mm
8mm
15mm
NRC = 0.50
CAC = 30 dB
85%
90% RH
3.0 kgs/m2
85
Recycled
Content
BEAUTI-SKY RH 80
Beauti-Sky
Beauti-Sky
86
ne
mi
ra
n
pla
ks
u
ea
ti-
BEAUTI-SKY RH 80
rh
ky
28%
LEED Credits
80
Energy
BOARD
TEGULAR
XL 24 mm
XL 24 mm
Daylight
& Views
9.5mm
14 mm
14 mm
D =7mm
NRC=0.50
CAC = 30 dB
80%
80% RH
2.6 kgs/m2
87
Recycled
Content
GRAPHIS
Design - Linear, Puntos, Cuadros
The geometric design of Graphis Linear
enables the creation of subtle shadow
effects. With a single texture,
a variety of patterns can be obtained.
The crisp, plaster like design of Graphis
Puntos and Cuadros, is suitable for
areas requiring high light reflectance
and a soothing atmosphere.
Unobtrusively these designs add
a quiet elegance to your required finish,
Graphis Cuadros
Graphis Cuadros
88
ne
mi
ra
l
b
r
oa
&
tile
47%
LEED Credits
s
g
p
ra
his
Energy
GRAPHIS
Linear
Puntos
15mm
30mm
BEVELLED TEGULAR
Suprafine 15 mm/Silhouette
4mm
R 6.4mm
Suprafine 15 mm/Silhouette
4mm
17mm
6.4mm
R 1.5mm
30
39.5mm
BEVELLED TEGULAR
Suprafine 15mm/Silhouette
4mm
17mm
6.4mm
R 6.5mm
Cuadros
5mm
BEVELLED TEGULAR
Daylight
& Views
4mm
17mm
6.5mm
R 6.5mm
17mm
6.5mm
aW
0.15(L)
Hz
NRC
0.15
125
0.35
250
0.20
EN 20354
& EN 11654
Dncw = 36 dB
EN 20140-9
& EN 717-1
EEA
Euroclass A2-s2, d0
RUS
@ 90%
70% RH
@ 6 kg/m2
89
Recycled
Content
VISUAL
Open Cell - V49, V64
Armstrongs Visual ceilings are available
in two open cell options and are designed
for installation on 15 mm suspension
systems. As well as enhancing the
ceiling design, product integration can
be arranged to provide specific acoustic
requirements in areas such as conference
or meeting rooms. Visual tiles provide
a monolithic ceiling appearance and
effectively integrate with recessed
luminaires, custom-made downlighters
and air handling diffusers.
Visual V49
Visual V49
Visual V64
90
70%
LEED Credits
ne
mi
ra
l
o
n
pe
ell
REDUCTION 63
u
vis
al
Energy
Daylight
& Views
A
B
A
B
V49
VISUAL
V64
A
B
A/58 mm
B/15 mm
C/6.50 mm
Open area: 45.6 %
Cut off angle: 18
A/47.20 mm
B/15 mm
C/6.35 mm
Open area: 39.6 %
Cut off angle: 22
BEVELLEDATEGULAR
C
B
BEVELLED TEGULAR
Suprafine 15 mm/Silhouette
Suprafine 15 mm/Silhouette
4.5mm
10mm
4.5mm
19mm
10mm
19mm
Hz
NRC 125 250 500 1000 2000 4000
V49 + fleece
0.50(H)
0.50 0.10 0.30 0.40 0.50 0.75 0.90 a P
V49 + fleece + 25 mm x 20 kg/m3 fibreglass overlay
0.95(H)
0.90 0.35 0.80 0.95 0.90 1.00 1.00 a P
aW
EN 20354
& EN 11654
EEA
Euroclass A2-s1, d0
RUS
70 % RH
@ 4 kgs/m2
91
Recycled
Content
CONTRAST RH 95
Design - Circles, Squares
The geometric patterns of
Contrast Circles and Squares are
recommended for areas requiring good
acoustical absorption, combined with
aesthetical requirements.
Contrast Circles
Circles
Squares
92
ne
mi
ra
l
b
r
oa
&
tile
s
c
tr
on
rh
st
33%
LEED Credits
95
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
CONTRAST RH 95
Circles
Squares
6mm
15mm
40mm
39.5mm
BEVELLED TEGULAR
BEVELLED TEGULAR
Suprafine 15 mm/Silhouette
Suprafine 15 mm/Silhouette
4.5 mm
4.5 mm
8mm
15mm
8mm
15mm
aW
0.55
Hz
NRC
0.50
125
0.40
250
0.40
EN 20354
& EN 11654
Dncw = 36 dB
EN 20140-9
& EN 717-1
EN 20140-9
& EN 717-1
EEA
Euroclass A2-s1, d0
RUS
@ 80%
95% RH
@ 4 kgs/m2
93
Recycled
Content
DUNE RH 99
Planks
Armstrong plank systems allow the
ceiling to integrate with the building
module and when featuring the SL2
edge detail these systems provide
full accessablity whilst minimising the
visible grid. Combining excellent sound
absorption and sound attenuation
performance, our Dune plank range
also offers a variety of sizes to suit the
flexible requirements of modern office
buildings.
Dune SL2
Dune
94
35%
LEED Credits
ne
mi
ra
n
pla
ks
e
un
99
rh
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
DUNE PLANKS RH 99
BOARD
TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
BEVELLED TEGULAR
9.5mm
16mm
16 mm
M=6.5mm
D =7.5mm
SL2
5mm
3mm
8mm
K2C2
12mm
9mm
16mm
2mm
11.5mm
13mm
18mm
17mm
9.5mm
26mm
Dune Planks 16 mm
aW
0.55
NRC
0.50
125
0.35
250
0.40
Hz
500 1000 2000
0.50 0.60 0.55
4000
0.40 a P
EN 20354
& EN 11654
@ 85%
99% RH
@ 4.5 kgs/m2
(17 mm)
95
18mm
Recycled
Content
Bioguard Plain
Bioguard Acoustic
96
ne
mi
ra
l
b
r
oa
&
tile
LEED Credits
in h 95
r
pla
d stic
r
ua ou
g
c
o
bi & a
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
BIOGUARD
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
Suprafine 15 mm/Silhouette
9.5mm
4.5 mm
16-19 mm
16/19mm
8mm
16-19 mm
M=6.5mm
D =7.5mm
Bioguard Plain
600 x 600 x 16 mm . . . . . . . . . . . . . . . . . . .H5180 . . . . . . . . . . . . . . . . . . . . . . . . . H5182 . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 16 mm . . . . . . . . . . . . . . . . . .H5181 . . . . . . . . . . . . . . . . . . . . . . . . . H5183 . . . . . . . . . . . . . . . . . . . . . . . . . .
Bioguard Acoustic
600 x 600 x 19 mm . . . . . . . . . . . . . . . . . . H5186 . . . . . . . . . . . . . . . . . . . . . . . . . . . H5188. . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 19 mm . . . . . . . . . . . . . . . . . H5187 . . . . . . . . . . . . . . . . . . . . . . . . . . . H5189. . . . . . . . . . . . . . . . . . . . . . . . . .
H5184 . . . . . . . . . . . .
H5185 . . . . . . . . . . . .
H5190 . . . . . . . . . . . .
H5191 . . . . . . . . . . . .
Hz
NRC
Bioguard Plain
0.15 (L)
0.15
125
250
0.30
0.20
0.15
0.10
0.20 0.25 P
Bioguard Acoustic
0.60 (H)
0.70 0.31
0.34
0.74
0.91
0.94 0.98 P
Quarternary Ammonium,
ASTM D-4828
@ 90%*
ISO 5#
95 % RH
@ 4.5 kgs/m2
(CLASS 100)
*BIOGUARD PLAIN
#
BIOGUARD ACOUSTIC
97
Recycled
Content
HEALTHZONE BASIC
HealthZone Basic
HealthZone Basic
98
ne
mi
ra
l
b
r
oa
&
tile
s
h
lt
ea
hz
e
on
ba
35%
LEED Credits
sic
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
HEALTHZONE BASIC
BOARD
TEGULAR
BEVELLED TEGULAR
Prelude XL 24 mm
Prelude XL 24 mm
Suprafine 15 mm/Silhouette
9.5mm
16mm
4.5 mm
16mm
8mm
16 mm
M=6.5mm
D =7.5mm
HealthZone Basic
600 x 600 x 16 mm . . . . . . . . . . . . . . . . . . .H3325 . . . . . . . . . . . . . . . . . . . . . . . . . H3327 . . . . . . . . . . . . . . . . . . . . . . . . . . H3329 . . . . . . . . . . . .
600 x 1200 x 16 mm . . . . . . . . . . . . . . . . . .H3326 . . . . . . . . . . . . . . . . . . . . . . . . . H3328 . . . . . . . . . . . . . . . . . . . . . . . . . . H3320 . . . . . . . . . . . .
CAC = 30 dB
@ 88%
99 % RH
@ 3.2 kgs/m2
99
Recycled
Content
Clean Room FL
Clean Room FL
100
ne
mi
ra
l
b
r
oa
&
tile
m
oo
n r lar)
a
e
cl (my
35%
LEED Credits
fl
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
BOARD
Prelude XL 24 mm
19mm
Field Unit
600 x 600 x 19 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1715 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 19 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1716 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Border Unit
600 x 600 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1720 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1721 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN 20354
& EN 11654
Dncw = 35 dB
EN 20140-9
& EN 717-1
ASTM E84
l = 0.067 W/mK
@ 79%
ISO CLASS 5
95% RH
@ 5 kgs/m2
(CLASS 100)
101
Recycled
Content
CERAMAGUARD RH 100
Ceramaguard
Fine Fissured
102
ne
mi
ra
l
b
r
oa
&
ti
les
c
a
er
ma
gu
d
ar
rh
10
34%
LEED Credits
Energy
Daylight
& Views
warranty
With Armstrong Steel Angle
BOARD
Prelude TL 24 mm
15mm
aW
0.55(MH)
Hz
NRC
0.60
125
0.25
250
0.30
EN 20354
& EN 11654
CAC = 38 dB
EN 20140-9
& EN 717-1
ASTM E84
ASTM E1264 classification Type XX (high density ceramic-like composition
with scrubbable finish) Pattern C
l = 0.052-0.057 W/mK
@ 82%
100% RH
@ 7 kgs/m2
@ 20 kgs/m2 if wet
103
Recycled
Content
TECHZONE
Building module 1200x1350. 1200x1200 mm Optra Bevelled Tegular tiles on Suprafine 38 steel angle.
104
te
ch
zo
ne
ce
ilin
te
ys
ms
te
ch
nic
pa
al
ne
ls
T e c h n i c a l P a n e l s wi d t h :
1 5 0 o r 3 0 0 *mm .
Technical Panels lengths:
1 2 0 0 , 1 5 0 0 *m m .
Section Drawing
* to be introduced shortly.
Suspension
Systems
Field Panel
Edge Details
Prelude 24
Technical Panel or
Technical Elements
Edge Details
Board
Prelude 24
Tegular 8 mm
Tegular 8 mm
Suprafine 15
Bevelled Tegular 8 mm
Bevelled Tegular 8 mm
E x am p l es of e d g e d e ta ils a r e s h o wn bel o w
T e g u l a r F i e l d P a n e l and Tegul ar
T e c h n i c a l P a n e l o n P relude 24.
FIELD/TECHNICAL PANELS
Tiles Performances
Steel Angle
Absorption
Attenuation
Light
Reflectance
Humidity
Resistance
Recycled
Content*
0.90
N/A
85%
95%
66(GW)/74(RW)%
Prelude 24
Prelude 15
SL2/ K2C2
Edge Detail
Optra
Ultima
only Field Panel
Dune Max
Dune
Metal Plain
only Technical Panel
0.70
35
89%
95%
70-80%
0.70
30
88%
99%
81-84%
0.50
34
83%
99%
38-41%
0.1
30-40
76%
95%
upto 25%
Edge Detail
Board
Tegul ar
B evelled Tegular
SL2
K 2C2
105
TECHZONE
te
ch
e
on
ce
ilin
sy
ste
ms
n &
tio
ra bilty
u
g ati
nfi
co omp
c
1200mm
1200mm
FP2
1200mm
1200mm
FP2
FP1
FP1
CT2
CT1
CT1
CT2
150mm
Step 1
Step 2
Ceiling
TechZone
TZ
Module
on centre
Orientation
mm
600mm
600mm
MR
1050mm
150mm
Step 3
1050mm
Step 4
Type
Step 5
Size
24 mm
24mm
24mm
15mm
mm
Board
Tegular
Semi
Bevelled
concealed
Tegular
spacing
1200
1200
1200
1200
1200
1200
TZ1, TZ2
TZ1,TZ2
TZ1,TZ2
Optra
Optra
Dune
1200X1050
600X1050
600X1050
1200
1200
TZ1,TZ2
Dune Max
600X1050
Dune
Dune
Metal
Max
1350mm
FP2
FP1
1200mm
1200mm
1350mm
FP2
FP2
FP1
FP2
CT2
CT1
CT1
CT1
600mm
600mm
MR
150mm
Step 1
Step 2
Ceiling
TechZone
TZ
Module
on centre
Orientation
mm
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
150mm
1200mm
Step 3
Type
TZ3,TZ4
TZ3,TZ4
TZ3,TZ4
TZ3,TZ4
TZ3,TZ4
TZ3,TZ4
TZ3,TZ4
TZ4
TZ4
TZ4
Optra
Optra
Ultima
Dune Max
Dune
Metal#
Metal#
Optra
Dune Max
Dune
106
Step 4
Size
24 mm
24mm
mm
Board
Tegular
spacing
1350
1350
1350
1350
1350
1350
1350
1350
1350
1350
1200mm
1200X1200
600X1200
600X1200
600 X1200
600X1200
600X1200
300X1200
300X1200
300X1200
300X1200
MR
Step 5
24mm
15mm
Semi
Bevelled
concealed*
Tegular
Dune
Dune
Metal
Max
te
ch
e
on
ce
ilin
sy
ste
ms
n &
tio
ra bilty
u
g ati
nfi
co omp
c
1500mm
1500mm
FP
1200mm
1200mm
TECHZONE
CT2
CT1
FP
CT1
CT2
150mm
1350mm
Step 1
Step 2
Ceiling
TechZone
TZ
Module
on centre
Orientation
mm
600mm
600mm
MR
150mm
Step 3
Step 4
Type
1200
1200
1200
1500
1500
1500
TZ5,TZ6
TZ5,TZ6
TZ5,TZ6
Optra
Dune Max
Dune
Step 5
Size
24 mm
24mm
24mm
15mm
mm
Board
Tegular
Semi
Bevelled
concealed*
Tegular
spacing
600X1350
600X1350
600X1350
MR
1350mm
Dune
1650mm
MR
MR
FP
FP
CT1
1200mm
1200mm
FP1
CT1
FP1
FP2
CT2
CT1
MR
1200mm
1200mm
MR
CT1
CT1
CT1
CT2
MR
MR
Step 1
Step 2
Ceiling
TechZone
TZ
Module
on centre
Orientation
mm
1200
1200
1200
1200
1200
1200
1200
1200
1200
1800mm
150mm
Step 3
Type
Step 4
Size
24 mm
24mm
mm
Board
Tegular
spacing
1950
1950
1950
1950
1950
1650
1650
1650
1650
TZ7
TZ7
TZ7
TZ7
TZ7
TZ8
TZ8
TZ8
TZ8
1950mm on centre
150mm
Metal
FP
Dune
Max
Optra
Ultima
Dune Max
Dune
Metal#
Optra
Optra
Dune Max
Dune
600X1200
600X1200
600x1200
600X1200
600X1200
750x1200
600X1500
600X1500
600X1500
Step 5
24mm
15mm
Semi
Bevelled
concealed
Tegular
Dune
Dune
Metal
Max
107
WOODWORKS
Tiles & Planks
WoodWorks is a range of wood finish
ceiling systems and wall panels.
Wood is the most beautiful and natural
element used in interior decoration
the world over. It enables designers to
create rich and warm interiors.
WoodWorks, with its premium looks
and exquisite shades, provides an
opportunity to create breathtaking
interiors.
WoodWorks
Square Tegular and
3600 Black
Silhouette
108
wo
od
r
wo
ks
tile
d
an
pla
nk
DESCRIPTION
FINISH
We offer a wide choice of beautiful veneers and laminates and a
variety of perforations; this allows great scope to create an interior
to suit your needs, combining the warm veneers, laminates and
the various perforation designs to improve both the aesthetics and
acoustical performance of the space.
GRID COORDINATION
MicroLook : For better coordination between grid and tile
use of Suprafine 15 mm steel angle system or Silhouette is
recommended.
Concealed Grid System - SL2: The WoodWorks SL2 ceiling range
provides a monolithic visual by hiding the steel angle system.
24 mm face Prelude 38 with spacer bar steel angle system is
recommended.
Wood, the most beautiful and vivid material for interior decoration,
will become your favored choice for exclusive projects in Retail
& Entertainment, Hospitality, Restaurants, Offices, Conference
Rooms, Specialty Stores.
INSTALLATION RECOMMENDATIONS
In order to obtain the best decorative effect, we advise you to
follow the points below: 1. Display all the panels before fitting
2. Arrange them aesthetically with regard to their shade and grain.
3. Install the ceiling tiles/ planks/ wall panels accordingly.
With each order, it is recommended to allow for some extra panels
to accommodate for visual variations.
PERFORATIONS
For improved acoustical performance, several perforation options
are available upon request such as diameter and percentage
of perforations. Armstrong introduces the Helmholtz resonator
perforation pattern in 3mm dia face pattern and grooved wall
panels to increase the acoustical performance.
Mineral Ceilings and Wood tiles can be integrated to create
excellent speech and listening qualities in any room, i.e. a sound
reflective ceiling in plain wood tiles mixed with absorbent material
can be utilized to optimize reverberation times.
Helmholtz Resonator
109
WOODWORKS CEILINGS
APPLICATIONS
WOODWORKS
Tiles & Planks
FINISHES
Laminates
US Maple
Maple
Royal Cherry
Dark Walnut
Wood Veneers
Maple*
Dark Bamboo*
Red Beech*
US Cherry*
PERFORATIONS
Standard perforations
Special perforations*
R3
R6
32
11
32
35.5
33
16
O6
O11*
6 40
44
67
32
12
O12*
12
67
R8*
25
47
SQ 50*
50
INSTALLATION
M6 Threaded Rod
Prelude 38
main runner
C-Channel Hanger
C-Channel
Stabiliser Bar
A
View A
110
wo
od
r
wo
ks
tile
d
an
WOODWORKS
pla
nk
SQUARE TEGULAR
Suprafine
SILHOUETTE
SL2
Silhouette
Prelude XL/TL 24 mm
10mm
5mm
Plain
R3
12mm
12mm
Plain
R6
R3
WOODWORKS CEILINGS
8mm
7mm
R6
Laminates:
Laminates:
600 x 600 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 600 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wood Veneers:
Wood Veneers:
600 x 600 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 600 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 x 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFORATIONS
Hz
Perforation R3 (3)
aW
NRC 125
0.25(H)
0.45 0.23
250
0.76
Hz
Perforation R6 (6)
aW
NRC 125
0.15(H)
0.30 0.56
UK Class 1Y ( BS 476)
250
0.64
l = 0.12 W /mK
70% RH
111
WOODWORKS LINEAR
WoodWorks
Linear
112
o
wo
r
wo
ks
s
tile
d
an
pla
nk
rks
wo
od ar
o
w line
WOODWORKS LINEAR
Prelude XL (Black)
with factory fitted clips for 115mm and 150mm modules
WOODWORKS CEILINGS
Dimensions:
2440X95X20 with 20mm reveal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2440X135X20 with 20mm reveal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Finish Selection
Natural Variations (Real wood veneers)
Beech
(NBE)
Maple
(NMP)
Light Cherry
(NLC)
Dark Cherry
(NDC)
Maple
(CMA)
Cherry
(CCY)
Walnut
(CWA)
Patina
(BAP)
Native**
(BAN)
** A premium veneer option managed through Architectural Specialities due to the potential for significant colour variation panel to panel.
Minimum order quantity and extended lead time may apply.
Due to printing limitations, shade may vary from actual product.
NRC
2440X95X20 with 20mm reveal . . . . . . . . 0.50 (0.65**)
2440X135X20 with 20mm reveal . . . . . . . . 0.40 (0.50**)
**when used with Acoustic infill
113
METALWORKS
FORM
FUNCTION
Armstrong Vector
114
t
me
alw
or
ks
METALWORKS
INSTALLATION
ENGINEERING STANDARDS
FLEXIBILITY
METALWORKS
115
METALWORKS
PERFORATIONS
2.15
2.15
5.5
5.5
2.5
2.5
4.3
Standard Perforated
16% open area
SPECIAL PERFORATIONS
116
1.5
2.15
5.5
4.3
Microperforated
22% open area
1.5
4.3
1.5
0.7
Extra Microperforated
1% open area
0.7
t
me
alw
or
ks
op
tio
ns
METALWOKS
LIGHT REFLECTANCE
COLOUR
Standard colour
Global White (12% gloss)
Colours available on request
RAL 9010
MATERIALS
Special colours
Other RAL colours available on request
RAL 9010
Global White
RAL 9006
Silver grey
RAL 9007
Gunmetal grey
METALWORKS
SECURITY
SEMI-STANDARD DETAILS
117
METALWORKS
Clip-In Swing-Down Bevelled Tiles & Planks
- Plain, monolithic surface
- Minimum plenum clearance
- Choice of dimensions
- Easy to clean
- Swing down option for easy access
Swing-Down tiles are particularly useful
in situations where regular access to
the ceiling plenum is required.
As with standard Clip-In, Clip-In
Armstrong Clip-In
Armstrong
Clip-In
118
APPLICATION AREAS:
- Corridors
- Hospitals
- Below service utilities
- Transportation nodes
me
tal
r
wo
ks
bo
ar
an
tile
s
cli
p-
in
(1)
Plain
Standard Perforated
Microperforated
Extra Microperforated
No perforation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 300 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 600 mm Swing Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
119
METALWORKS
Clip-In 3 mm Bevel
STEEL
600 x 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 300 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 600 mm Swing Down . . . . . . . . . . . . . . . . . . . .
ALUMINIUM
600 x 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
METALWORKS
Stainless steel Clip-in Tiles
- Plain, monolithic surface
- Mirror finish which creates an illusion
of spaciousness
- Suitable for hygienic areas
- Very high degree of corrosion resistance
- Easy to clean
- Washable
- Minimum plenum clearance
Armstrong Clip-In
Armstrong
Clip-In
120
APPLICATION AREAS:
- Healthcare
- Kitchen/Pantry
- Dining Areas
- Industrial clean rooms
- Retail Boutiques
- Exhibition areas
t
me
alw
or
ks
tile
cli
p-
in
(1)
Plain
No perforation
METALWORKS
C Channel
BPAC1938
DP12 Hanger
BPAM1640H
Armstrong Clip-in system
Wall Molding
BPT1932H
DP12 Connector
BPAM1640C
Spring Clamp
BPT1932HC
C Channel Hanger
BPAC1938H
121
METALWORKS
Lay-in
- Fully demountable
- Easy to replace
- Square tegular to be installed either on
Suprafine or Silhouette
- Easy access to plenum
Square Tegular
122
me
w
tal
or
ks
bo
rd
&
tile
s
lay
-in
(1)
SQUARE TEGULAR
Plain
Perforated
Microperforated
Extra Microperforated
No perforation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.5
123
METALWORKS
STEEL
600 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALUMINIUM
600 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
METALWORKS
Vector
- Can be installed with a very low
void depth
- Clean crisp detailing of 6 mm reveal
- Easy to install and remove without
tools
- Downwardly accessible
- Minimal disruption
- Strongly formed edge resists damage
Armstrong Vector
Vector
124
me
w
tal
or
ks
bo
rd
&
tile
s
ve
cto
(1)
VECTOR
Plain
No perforation
Microperforated
Extra microperforated
Prelude XL2 24 mm
0.5
600 x 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1200 x 300 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1200 x 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300 x 300 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
400 x 1200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 mm
non-engaging edge
engaging edge
Installation Sequence
spring edge
125
METALWORKS
STEEL
METALWORKS
Planks
Armstrong metal planks are available
in lengths between 900mm and 3000
mm.
Choose between Clip-in system (1200
x 300 mm) and Carrier bar systems
(ideal for external application)
The concealed appearance of
planks minimises the visibility of the
Dark Cherry
Cherry
Maple
126
t
me
alw
or
ks
pla
nk
(1)
METAL PLANKS
Plain
Perforated
Microperforated
Extra Microperforated
No perforation
15/30
300
1200-3000
15mm height for 85, 100, 150 and 200mm plank widths. 30mm height for 300mm plank widths
0.5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALUMINIUM
85xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
150xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
200xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300xLx30mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
127
METALWORKS
STEEL
85xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
150xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
200xLx15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
300xLx30mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
METALWORKS
Linear
Nominal 100mm, 200mm, and 300mm
wide panels, including nominal 25mm
reveal
Acoustical options with microperforated
panels
Available in white color and three
Effects Wood Looks finishes
Install in the ceiling, on the wall, or
create 90 angled or curved ceiling-towall
MetalWorks Linear
Dark Cherry
(FXDC)
Cherry(FXCH)
Maple(FXMP)
White(WH)
128
transitions
Fast and easy installation
Durable - Washable, Scrubbable,
Impact-resistant, Soil-resistant
MetalWorks Linear is ideal for:
- Open plan spaces
- Foyers / lobbies
- Reception areas
- Airports / Transport terminals
- Waiting areas
- Meeting rooms
- Restaurants
t
me
alw
or
ks
lin
ea
(1)
METALWORKS LINEAR
Plain
Microperforated
No perforation
STEEL
2440 x 100 x 16 mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2440 x 200 x 16 mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2440 x 300 x 16 mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
METALWORKS
Flex Carrier
Molding (at wall)
Rigid
Attachment
Clip 6459BL
Wall
Pressure Spring
RC2BL Clip
Flex Carrier
Filler Strip
(Optional)
Screws
Flex Carrier
Drywall Grid
Main Beam
Panel
Splice Plate
129
METALWORKS CELLIO
Open Cell
Armstrong offers a unique solution for
your open plenum ceiling requirements.
Lay-in System (Cellio) - Compatible with
Armstrong 15 mm Suprafine metal angle
system.
Cellio offers a great deal of flexibility
allowing you to use it with a combination
of mineral fibre, metal or wooden ceiling
tiles without requiring elaborate transition
Cellio
Cellio
130
t
me
alw
or
ks
o
n
pe
ce
ll
CELLIO
ce
llio
Cellio C64
75 x 75 mm
Cellio C36
100 x 100 mm
Cellio C16
150 x 150 mm
64%
31
5.10 kg
72%
23
3.85 kg
81%
15
2.60 kg
Open area
Cut off angle
Weight kg/m2
Cellio C9
200 x 200 mm
85%
11
2.10 kg
METALWORKS
Suprafine 15 mm
38 mm
600 x 600 x 38 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Colours: Cellio is available in white and black (BK) and is compatible with our standard Trulok colour range.
INSTALLATION
131
METALWORKS
Mesh Lay-in
This ceiling provides a sense of openness and beautiful aesthetics, creating
a unique visual identity for your space.
With benefits such as
- Ease of installation
- Superior aesthetics and
- Easy installation and removal
without tools,
Mesh Lay-in
Panels
132
t
me
alw
or
ks
p
e
an
ls
s
me
ay
h l
-in
(1)
Fill Wire
Diameter
LWO
Fill Wire
Spacing
SWO
LWD
Warp Wire
Spacing
WOVEN WIRE
# 6129AM
610 x 610mm
6.4/15/6.4/15mm
6.4/15/6.4/15mm
2mm
2mm
61%
# 6412AM
610 x 610mm
6.4/15/6.4/15mm
6.4/15/6.4/15mm
2.4mm
2.4mm
53%
# 6128AM
610 x 610mm
80.01mm
9.8mm
3.05mm
2.35mm
62%
Lattice flat
Linen web
Cascades
EXPANDED METAL
Item:
Dimensions:
SWD:
LWD:
SWO:
LWO:
Open Area:
# 6139AM
610 x 610mm
37.45mm
76.03mm
25.25mm
62.7mm
49.46%
# MWHS01WE1AWE
600 x 610mm
8.25mm
26.17mm
3.25mm
26.17mm
41.76%
Triple Narrow
METALWORKS
Item:
Dimensions:
Warp Spacing (Pattern):
Fill Spacing (Pattern):
Warp Wire Diameter:
Fill Wire Diameter:
Open Area:
SWD
# MWHA01LE1AWE
600 x 600mm
14.04mm
30.32mm
7.65mm
22.55mm
30.9%
Mesh
Stainless steel angle
133
METALWORKS
Concave, Convex and Double Curved Ceilings
Curved ceilings are available in convex
and concave shaped patterns, with
a variety of perforation options for
acoustics, three different colour options
and no visible metal angle for unique
design solutions.
Double Curved ceiling options are
available in plain and perforated
options to create signature spaces.
Use perforated panels to combine
functionality with aesthetics.
Concave and
convex ceilings
134
- Hospitals and
- Transportation
Double Curved ceilings are ideal for
- Corridors
- Private offices
- Lobbies
- Retail and
- Accent areas
t
me
alw
or
ks
pa
ne
ex ing
nv eil
co d c
d
e
an urv
ve le c
a
nc ub
co do
&
ls
(1)
Plain
Microperforated
Perforated
No perforation
8 mm dia. holes
41.5 % Open area
CONCAVE
900 x 600 x 1 mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONVEX
900 x 600 x 1 mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DOUBLE CURVED
600 x 300 x 1.5 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Concave, Convex and Double Curved Ceilings available in Aluminium.
Concave Panel
Convex Panel
Gasket
14.98
border 12.82
R1219.2
59.1
60.1
Concave
61.33
2.99
Gasket
R1219.2
88.34
911.27
911.54
Section
Convex
14.98
88.39
2.99
Perforation pattern
90
90
Gasket
Concave Border
1.5
60.3
Plan
Gasket
54.99
Perforation pattern
4.3 4.3
4.3 4.3
1.5
border 12.82
Gasket
607.59
4.3 4.3
607.59
4.3 4.3
135*4.3 = 580.5
Surface
Spacer bar
Double Curved Panel
Suspension rods
300
0.8
11
Gasket
11
Plan
670
28
R270
Gasket
60.34
12
10
R270
12
30
Double Curved
ceiling panel
16
Section
J-carrier bar
Special Perimeter (end & border) Tiles available as shown in the drawing above. Please contact the company representative for more details.
* Available ready stock: Concave/Convex panel Plain and Microperforated in Silver Grey Colour. Special border, edge and corner tiles are available.
(1) For short term exposure or back painted products.
135
METALWORKS
911.27
911.54
Gasket
METALWORKS BAFFLES
Metalworks Baffles
Metalworks
Baffles
136
t
me
alw
or
ks
pa
ne
ls
ba
ffle
(1)
METALWORKS BAFFLES
DROP ROD
UNIGRID CLIP
LOCKING CLIP
Finish Selection
Solid Colours
White
SUSPENSION CLIP
UNIGRID
Wood Finish
Black
Cabrueava
Pradoo
METALWORKS
Baffle
25X100X3600mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25X150X3600mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION
Suspension Clip
Locking clip
Baffle Hanger
Unigrid Channel
Baffle
End cap
A
100mm Baffle @100mm centres: 10.20 kgs/m2
150mm Baffle @100mm centres: 19.80 kgs/m2
137
METALWORKS
Technical Pages
ACOUSTIC PERFORMANCE
Hz
NRC 125 250 500 1000 2000 4000
Extra Microperforated with fleece (EN 2253)
0.55(L)
0.65 0.45 0.75 0.70 0.55 0.55 0.45 a P
Extra Microperforated with B15 (EN 2334)
0.65
0.60 0.40 0.45 0.55 0.70 0.80 0.70 a P
Microperforated with fleece (EN 2175)
0.75
0.80 0.30 0.75 0.90 0.65 0.75 0.80 a P
Microperforated with B15 (EN 2337)
0.60(H)
0.60 0.40 0.40 0.50 0.65 0.75 0.90 a P
Perforated with fleece (EN L/2463)
0.70(L)
0.70 0.40 0.75 0.65 0.65 0.75 0.75 a P
Perforated with B15 (EN 2340)
0.60(H)
0.60 0.40 0.45 0.50 0.65 0.75 0.90 a P
Plain - no infill (EN 2206)
0.10(L)
0.10 0.25 0.15 0.10 0.10 0.10 0.10 a P
aW
EN 20354
& EN 11654
138
me
tal
r
wo
ks
te
ch
a
nic
a
l p
ge
METALWORKS
LIGHT REFLECTANCE
Pattern
RAL 9010
Global White
87%
77%
76%
75%
68%
71%
63%
Plain (unperforated)
METALWORKS
139
SOUNDSCAPES CANOPIES
SoundScapes Canopies
SoundScapes
Canopies
140
&
ies
op uds
n
ca clo
es
ap
sc ies
d
p
un
so cano
(1)
SOUNDSCAPES CANOPIES
Panel Profile
Large
Hill
Small
Valley
Valley
Hill
1181X1905X32mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
914X914X32mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Finish Selection
Traffic
White
RAL 9016
Light
Ivory
RAL 1015
Pale
Green
RAL 6021
Pastel
Blue
RAL 5024
Traffic
Grey
RAL 7042
Pale
Brown
RAL 8025
aW
0.80(H)
Hz
NRC
0.85
125
0.70
250
0.95
GB 8624-2006 - A2-s1, dO
Hill
Valley
spiral anchor
141
SOUNDSCAPES SHAPES
SoundScapes Shapes
SoundScapes
Shapes
142
system, or on a wall
Shapes can also hung on walls using
special wall kits
SoundScapes Shapes are ideal for:
- Hospitality
- Retail
- Offices
- Reception Areas, Atriums
- Open Plenum Areas
-Transportation, Airports
- Exhibitions
&
ies
op uds
n
ca clo
e
ap
sc s
d
un pe
so sha
(1)
SOUNDSCAPES SHAPES
NOMINAL SIZE
SMALL RECTANGLE
LARGE RECTANGLE
Shapes
1200X1200mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1200x1800mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1200x2400mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Finish Selection
Traffic
White
RAL 9016
Light
Ivory
RAL 1015
Pale
Green
RAL 6021
Pastel
Blue
RAL 5024
Traffic
Grey
RAL 7042
Pale
Brown
RAL 8025
Acoustic Solutions
SoundScapes Shapes
@25% of ceiling
78 Panels: Squares
SoundScapes Shapes
@50% of ceiling
156 Panels: Squares
1.3
62%
-3dB
78 panels@2.48 Sabin/
panel = 193.4 Sabin
0.8
76%
-5dB
156 panels@ 2.48 Sabin/
panel = 386.9 Sabin
No Ceiling
Exposed
Structure
Reverberation Time (sec)
3.4
RT Improvement (%)
ref
Sound Level Reduction (dB)
ref
Sound Absorption In Sabin
ref
(metric) for Coverage Area
Notes: All values for the averaged sound absorption co-efficient, Sabin absorption and dB level reduction of 125Hz, are based on the speech
frequency range of 500and 1000Hz. Reverberation time is an average of 500 and 1000Hz only. Sabin Values are all metric
GB 8624-2006 - A2-s1, dO
4 square
4 linear
9 square
Large/small
rectangle
7 circle
/hexagon
Individual suspension
Group configurations*
143
Infusions Accent
Canopies
144
- Avenues
- Corridors
- Breakout Zones
-Restaurants and Hotels
&
ies
op uds
n
ca clo
s
ion pies
us
inf cano
(1)
Tone-on-tone
Gold tone
Alloys
Crystallines
Arbors
Linen
1220X3050X16mm . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
610X1525X6mm
. . . . . . . . . . . . .. . . . . . . . . . . . .. . . . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . . . . .. . . . . . . . . . . . .. . . . . . . . . .
.....
610X1830X6mm
. . . . . . . . . . . . .. . . . . . . . . . . . .. . . . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . . . . .. . . . . . . . . . . . .. . . . . . . . . .
.....
When specifying or ordering, include the appropriate three-letter or four letter (Graphix) color suffix. * Infusions Alloy Canopies thickness (3mm) differs from other 610mmX1525mm
and 610mmX1830 canopies (6mm). NOTE: For accessory information, visit Armstrong.com/infusions
Finish Selection
Channeled
Channeled
Mist
(CHT)
Tone-on-tone
Channeled
Carribean
(CHC)
Channeled
Midnight
(CHM)
Channeled
Sunset
(CHS)
Channeled
Fire
(CHF)
Channeled Channeled
Vision
Intellect
(CHV)
(CHN)
Gold tones
Honey
Canvas
(THC)
Alloy
Mica
Weave
(TME)
Spun
Copper
(TSC)
Crushed
Copper
(TCC)
Arbors
Crystalline
Silverado
(TSV)
Linen
Gold
(TLG)
Chalk
Folio
(TCF)
White
Circles
(TWC)
Silver
Orbit
(TSR)
Indigo
Surf
(TNS)
Blue
Arbor
(TBA)
Orange
Arbor
(TOA)
Red
Arbor
(TRA)
Crystallines
Simplicity
Alloy
(MSA)
Perforated
Alloy
(MPA)
Clear
Arbor
(TCA)
Linens
Crystalline
Focus
(TCR)
Crystalline
Sky
(TSY)
Natural
Linen
(TNL)
Blue
Linen
(TBL)
Panel material
Solid polycarbonate
Channeled polycarbonate
Aluminium
2pc
19kg
5.45kg
19kg
1 pc
9.5kg
2.75kg
9.5kg
610X1830mm
2 pc
22.68kg
6.35kg
22.68kg
1 pc
11.33kg
3.20kg
11.33kg
220X3050mm
2 pc
1pc
n/a
n/a
23.58kg 11.80kg
n/a
n/a
145
OPTRA
Wall Panels
Optra wall panels effectively control
unwanted noise. The key feature of
this engineered system is a glass wool
acoustical inner core, for superior
sound absorption, covered with a
special fire resistant fabric.
EASY INSTALLATION
Optra wall panels can be installed
over existing walls or directly to studs
with minimal workplace disruption.
Standard installation is with impalers. J
or Z splines may be used to create an
exposed system
APPEARANCE
Available in a standard width of
600 mm and in a variety of lengths,
ACOUSTICAL PERFORMANCE
Optra wall panels absorb 90% of
sound striking the surface - reducing
146
wa
ll p
e
an
ls
tile
d
an
pla
nk
s
op
tra
25/50 mm
25/50 mm
Square Edge
Bevelled Edge
600 x 600 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
........................
600 x 600 x 50 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1800 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 1200 x 50 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
........................
600 x 1800 x 50 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2100 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2100 x 50 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600 x 2700 x 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
........................
600 x 2700 x 50 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
aW
0.85
Hz
NRC
0.95
125
0.38
250
0.76
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
125
250
500
1000
2000
4000
Fabric
Burgundy 387
Rust 388*
Mocha 391*
White
Grey
Black
Blue
Beige
WALL PANELS
Ivory 380
Woven
Scrim
147
WOODWORKS
Wall Panels
WoodWorks is a range of wood
finish wall panels. Its premium looks
and exquisite shades of veneers and
laminates can create breath-takingly
rich and warm interiors.
Woodworks perforated wall panels
are available in 600x800 mm and
channeled perforation in size 2440x128
mm. Special channeled panels with
edge detail that conceal joints afford a
monolithic look to the premises.
For improved acoustical performance,
WoodWorks Wall Panel
148
APPLICATIONS
WoodWorks will become your first
choice for premium projects in Retail &
Entertainment, Hospitality, Restaurants,
Offices, Conference Rooms, and
Specialty Stores.
ll
wa
e
an
ls
s
tile
d
an
pla
nk
s
o
wo
dw
or
ks
WOODWORKS
Plain
R3
R6
Laminates:
600 x 800 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2440 x 128 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wood Veneers:
600 x 800 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2440 x 128 x 15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .
06
G14
G28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Perforations :
Perforated wall panels
4
2
R3
32
35.5
33
32
R6
16
O6
G14
28
14
6 40
G28
All measurements in mm.
Hz
*Perforation G14
aW
NRC
0.55(H)
0.60
125
0.35
250
0.76
WALL PANELS
Laminates
US Maple
Maple
Royal Cherry
Dark Walnut
Wood Veneers
White
Papyrus Grey
Aluminium Grey
Maple*
UK Class 1Y ( BS 476)
Dark Bamboo*
Red Beech*
l = 0.12 W /mK
US Cherry*
70% RH
149
SUSPENSION SYSTEMS
THE
SUSPENSION SYSTEM
RANGE
PEAKFORM
150
XL STAB
ion s
ns
pe stem
s
su sy
XL STAB INSTALLATION
COLOUR
ENVIRONMENT
As with all its solutions, Armstrong produces and distributes steel angle systems
in line with its commitment to the environment. Armstrongs suspension systems
contain up to 25% of recycled content. Up
to 100% of the packaging is made from
recycled material. Moreover, Armstrong pays
attention to the quality of all its products to
enhance their durability, maintenance and
longevity.
DESIGNER SERIES
STITCHING
NON CORROSIVE
SUSPENSION SYSTEMS
151
A X I OM Peri m eter T ri m
Knife Edge
AXIOM
with
Tegular edge
panel
152
ion s
ns
pe stem
s
su sy
er
et
im trim
r
pe
ax
iom
K n i f e E d g e pro f i l e
outside corners
AXIOM sections are produced in
standard 3,000mm lengths.
Typical Applications
- Retail
- Hospitality (clubs, restaurants, hotels)
- Offices (reception areas, lobbies,
board rooms)
- Healthcare
- Education
PHYSICAL DATA
K n i f e E d g e AXIOM wi th Pl as terbo ard T ri m (AX DWT)
Material
Trim Channel: Extruded aluminium, alloy 6063
Hanging Clip: Galvanised steel
T-Bar Connection Clip: Galvanised steel
Splice Plate: Galvanised steel
Colours
Coordinate with Armstrong Global White ceiling and suspension
systems. Custom colours are available upon request based on
minimum quantity
Kn i f e Edg e Alignme nt
P l ate (AXKE ALI GN)
Surface Finish
Durable polyester powdercoat
SUSPENSION SYSTEMS
153
19mm
19mm
150mm
19mm
100mm
50mm
F i e l d c u t / f a c t o r y mi tered
c o r n e r s a ss e m b l e d u s i n g
A x i o m S p l i c e P l a te
Cl as s i c AXIOM T ri m p rofile s
C l a s s i c A X I O M wi th T eg u l ar edg e pan el
PHYSICAL DATA
C l a s s i c A X I O M wi th P l as terbo ard T ri m (A XBT )
Material
Trim Channel: Extruded aluminium, alloy 6063
Hanging Clip: Galvanised steel
T-Bar Connection Clip: Galvanised steel
Splice Plate: Galvanised steel
Colours
Coordinate with Armstrong Global White ceiling and suspension
systems. Custom colours are available upon request based on
minimum quantity
T - B a r C o n n e c t o r Cl i p (A XT BC)
w i t h C l a s s i c A X I OM
Surface Finish
Durable polyester powdercoat
Cross Tee/Main Beam Interface
Flush fit
End Detail
Splice Plate and set screws
S p l i c e P l a t e ( A X 4 S P L ICE)
154
ion s
ns
pe stem
s
su sy
r
ne
sig ries
e
d se
r
ste
ra em
d
t
n
ba sys
SUSPENSION S YSTEMS
BANDRASTER
BANDRASTER SECTIONS
BANDRASTER ACCESSORIES
Item Nr.
Dimensions
length (mm) width (mm)
Slotted at 300 mm
BP 36 10 50 A
BP 36 10 75 A
BP 36 11 00 A
BP 36 11 25 A
BP 36 11 50
3600
3600
3600
3600
3600
50
75
100
125
150
Slotted at 312.50 mm
BP 36 2100 B
3750
100
Slotted at 100 mm
BP 36 30 50
BP 36 30 75
BP 36 31 00 WR
BP 36 31 25
BP 36 31 50
3600
3600
3600
3600
3600
50
75
100
125
150
Unslotted
BP 36 00 50
BP 36 00 75
BP 36 01 00
BP 36 01 25
BP 36 01 50
3600
3600
3600
3600
3600
50
75
100
125
150
A
A
A
A
Item Nr.
Description
Dimension
width (mm)
BPA 36 05 01
BPA 36 07 51
BPA 36 10 01
50
75
100
36
36
36
36
36
05
07
10
12
15
02
52
02
52
02
G
G
G
G
G
Nonius hanger
50
75
100
125
150
BPA
BPA
BPA
BPA
BPA
36
36
36
36
36
05
07
10
12
15
03
53
03
53
03
G
G
G
G
G
Splice
50
75
100
125
150
BPA
BPA
BPA
BPA
BPA
36
36
36
36
36
05
07
10
12
15
04
54
04
54
04
G
G
G
G
G
Cross connector
50
75
100
125
150
BPA
BPA
BPA
BPA
BPA
36
36
36
36
36
05
07
10
12
15
05
55
05
55
05
G
G
G
G
G
Wall connector
50
75
100
125
150
Crossing element
50
75
100
BPA 36 05 06 G
BPA 36 07 56 G
BPA 36 10 06 G
SUSPENSION SYSTEMS
BPA
BPA
BPA
BPA
BPA
155
ion s
ns
pe stem
s
su sy
PRELUDE 24
o
xp
sy
ed
ste
m
p
lu
re
de
24
SUSPENSION SYSTEMS
24 mm XL PRELUDE PEAKFORM
Item Nr.
BP 73 40 42
BP 73 42 52 P
BP 312061
Component
Main Runner
1200 mm cross tee
600 mm cross tee
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3600
1200
600
43
35
27
23.78
24 mm XL PRELUDE 38
Item Nr.
BP 73 40 32
BP 31 30 31
BP 31 20 31
Component
Main Runner
1200 mm cross tee
600 mm cross tee
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3600
1200
600
38
38
38
15.34
24 mm XL PRELUDE 32
Item Nr.
BP 73 42 101
BP 71 30 62
BP 71 20 11
156
Component
Main Runner
1200 mm cross tee
600 mm cross tee
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3600
1200
600
32
27
25
7.05
7.05
sy
ed
ste
15
ion s
ns
pe stem
s
su sy
ex
SUPRAFINE 15
os
su
fi
ra
ne
SUSPENSION SYSTEMS
Cross Tee 15 XL
Peakform
15 mm SUPRAFINE PEAKFORM
Item Nr.
BP 75 40 42
BP 75 30 42
BP 75 20 42
Component
Main Runner
1200 mm cross tee
600 mm cross tee
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3600
1200
600
43
43
43
23.71
23.71
15 mm SUPRAFINE 38
Item Nr.
BP 73 42 101
BP 71 30 62
BP 71 20 11
Component
Main Runner
1200 mm cross tee
600 mm cross tee
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3000
1200
600
38
38
38
7.57
14.0
15 mm SUPRAFINE 32
Item Nr.
BP 75 42 102I
BP 75 30 102
BP 75 20 11I
Component
Main Runner
1200 mm cross tee
600 mm cross tee
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3000
1200
600
32
32
32
7.57
7.57
SUSPENSION SYSTEMS
157
ion s
ns
pe stem
s
su sy
ex
os
sy
ed
ste
m
sil
e
ou
tte
15
SUSPENSION SYSTEMS
Silhouette with 6 mm reveal is available either in Armstrong Global White or Global White with black reveal (BI).
Component
BP 80 40 82/Bl
Main Runner
BP 80 30 82/Bl 1200 mm cross tee
BP 80 20 82/Bl 600 mm cross tee
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3600
1200
600
45
45
45
15.68
15.68
Component
BP 80 42 32/Bl
Main Runner
BP 80 30 32/Bl 1200 mm cross tee
BP 80 20 32/Bl 600 mm cross tee
158
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
3000
1200
600
38
38
38
11.25
11.25
ion s
ns
pe stem
s
su sy
SELECT 15 MM
ex
po
sy
ed
ste
m
se
lec
5
t 1
SUSPENSION SYSTEMS
15 mm SELECT
Item Nr.
Component
Dimensions
length height
System load
carrying capacity
(mm)
(mm)
kg/m2
32
32
32
10.12
7.0
SUSPENSION SYSTEMS
159
ion s
ns
pe stem
s
su sy
ce
on
i-c tem
m
s
se sy
ale
/
L2
K2
C2
SUSPENSION SYSTEMS
K2C2 Installation
SL2 INSTALLATION
1200 mm
Detail
Item no
Height
Width
Length
Prelude 38
Main Beam
734032
38
24
3600
Prelude 38
concealed grid
743032
38
24
1200
Stabiliser
Bar
Prelude 38
Main Runner /Concealed Grid
7431
22
22
1200
1500 mm
Detail
Item no
Height
Width
Length
Prelude 38
Main Beam
Prelude 38
concealed grid
734032
38
24
3600
743632
38
24
1500
Main Bar
C-Spline
without lock
Stabiliser
Bar
Stabiliser Bar
7436
22
22
1500
22
K2C2 INSTALLATION
1800 mm
Detail
Item no
Height
Width
Length
4740092S34
50
32
3600
743494C
50
11
1800
Locking
C-Splines
Jaw
Clip
743494CT
50
11
1800
GM1220
5
20
20
Main Bar
2100 mm
Detail
Item no
Height
Width
Length
Main Bar
4740092S34
50
32
3600
C-Spline
without lock
747394C
50
11
2100
Locking
C-Splines
Jaw
Clip
747394CT
50
11
2100
GM1220
5
20
20
Locking
C-Splines
Jaw
Clip
747094CT
35
11
2400
GM1220
5
20
20
Locking C-Splines
2400 mm
Detail
Item no
Height
Width
Length
160
Main Bar
4740092S34
50
32
3600
C-Spline
without lock
747094C
50
11
2400
22
Jaw Clip
ion s
ns
pe stem
s
su sy
s
n
sio rie
en esso
p
s
su acc
SUSPENSION SYSTEMS
SUSPENSION ACCESSORIES
SUSPENSION SYSTEMS
In order to ascertain the method of suspension, please contact your local representative.
161
ion s
ns
pe stem
s
su sy
o
xp
se
d s
te
ys
ism
se
& ies
l
rsa sor
ive es
un acc
ic
SUSPENSION SYSTEMS
UNIVERSAL ACCESSORIES
PBM9004MIP-Lay in
Infill Panels. Used with
MetalWorks Open Cell
(Cellio & Gridal). Facilitates
installation of Services like
down lighters, Sprinklers,
and Smoke detectors.
STAC-Single Tee
Adapter Clip. Secures main
beam to cross tee connections
SEISMIC ACCESSORIES
162
ion s
ns
pe stem
s
su sy
o
xp
se
te
ys
ss
ce
ac on
c
i
ti
ism lla
se insta
or
ies
SUSPENSION SYSTEMS
SEISMIC ACCESSORIES
200mm
200mm
22mm
22mm
200mm
38mm
600mm
19mm
22mm
19mm
22mm
10mm
22mm
600mm
SUSPENSION SYSTEMS
163
ion s
ns
pe stem
s
su sy
o
xp
se
d s
te
ys
ss
ce
ac on
c
i
ti
ism lla
se insta
or
ies
SUSPENSION SYSTEMS
Steps 1-3
Step 4
Step 6
Step 5
Step 7
164
Complete
ion s
ns
pe stem
s
su sy
p
us
en
ha
ion
ng
s
er
te
ys
int
r
eg
ati
on
SUSPENSION SYSTEMS
SYSTEM INTEGRATION
The chart below presents the Trulok steel angle systems with their related ceiling product families.
AXIOM (Transition/Profile)
SILHOUETTE*
SUPRAFINE
Bevelled Tegular
Tegular
Board
SL2/K2C2
Metal Axal
Vector
PRELUDE
BANDRASTER
Metal Tegular
Metal Board
Metal Planks
* Only in 6 mm reveal.
SUSPENSION SYSTEMS
165
166
Armstrong specifications.
G. Prior to installation, the acoustical material must
be kept clean and dry and below 120F (49C)
and in spaces outlined in paragraph C above.
H. Before Armstrong ceiling materials are installed,
the cartons containing the ceiling tiles should
be opened and the tiles should be permitted to
reach room temperature for at least 48 hrs and
have stabilized moisture content.
Fiberglass Commercial Ceiling with RH 95
performance and Steel angles Ten (10) Years
Limited Warranty
Armstrong Commercial Steel angles and Fiberglass
Commercial Ceilings when installed together are
warranted by Armstrong to be free from sagging,
warping or delamination as a direct result of defects
in material or factory workmanship for ten (10) years
from the date of installation.
A. The material shall be installed in accordance with
all applicable Armstrong specifications in effect
at the time of the installation.
B. The material may be installed in areas between
40F (4C) and 113F (45C) and in spaces
before the building is enclosed, where HVAC
systems are cycled or not operating. These
ceilings cannot be used in exterior applications,
where standing water is present or where
moisture will come in direct contact with the
ceiling.
C. The acoustical material must not be used to
support any other material except fiberglass
thermal/sound control insulation installed in the
thickness, density and manner specified by
Armstrong.
D. The warranty is void if the acoustical material is
installed on furring strips or installed by nailing
or stapling, or if any adhesive is used in the
installation process.
E. This warranty does not extend to acoustical
material which suffers damage caused by fire, or
the elements, or any form of physical abuse.
F. Performance issues which may result from the
presence of standing water, or where moisture
is in direct contact with the ceiling, such as
those resulting from conditions such as building
leaks or condensation, are not covered by
this warranty nor are they the responsibility of
Armstrong.
G. Prior to installation, the acoustical material must
be kept clean and dry. In conditions specified in
paragraph B above.
H. Before Armstrong ceiling materials are installed,
the cartons containing the ceiling tiles should
be opened and the tiles should be permitted to
reach room temperature for at least 48 hrs and
have stabilized moisture content.
Commercial Ceilings with RH 90 & RH 100
performance and Steel angles Ten (10) Years
Limited Warranty
Armstrong Commercial Steel angles and Ceiling
Panels with RH 100 or RH90 performance, when
installed together are warranted by Armstrong for
ten (10) years from the date of installation against
sagging, or warping as a direct result of defect in
material or factory workmanship.
A. The material shall be installed in accordance with
all applicable Armstrong specifications in effect
at the time of the installation.
B. Damage which may occur from chemical
fumes, freezing temperature, vibration and
abuse is not covered by this warranty, with the
sole exception being Armstrong Ceramaguard
RH 100 ceilings, which are covered by this
warranty even if exposed to chemical fumes
and extreme temperatures up to 120F (49C),
steam to 275F (135C) when installed on
either Armstrong 24mm SS, PRELUDE XL or
Armstrong 24mm AL steel angle system.
C. Installation shall be carried out in temperature
conditions up to 104F (40C), and relative
167
Advisory note
All photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named
in this brochure as to the proper use or recommended methods of installation of suspended ceilings and are supplied only
as informative material. For technical reasons in printing, differences may appear between colours printed in this brochure and the actual
product. The choice of colours should always be made from a sample of the product.
All statements and technical information contained in this brochure, or any publication of the companies named in this brochure, relating
to Armstrong ceilings are based on results obtained under laboratory test conditions. It is the responsability of the user to verify with the seller of
the products in writting that such statements and information are appropriate to the specific use intended. Sales of the products and liability of
the selling companies are in accordance with the terms and conditions of sale of the selling company.
All product specifications are subject to modifications without prior notice.
168