Académique Documents
Professionnel Documents
Culture Documents
[Third Printing]
p. 79
p. 91
In the last equation in Table 4-1, the minus sign should be replaced by an equal sign
p.144/145
Negative signs should be placed in front of P in the bottom two equations on page
144; The signs in front of P in the two terms in the last equation on p. 145
shouldeach be reversed
p. 171
p. 265
p. 302
p. 306
p. 323
p. 332
p. 333
Problem 11-13: Should read - "of gaseous cumene at 0.22 Mpa and 280 C"
p. 346
First row of Table 12-3: C2 and d values are incorrect, should read, C2 = 1.0, d = 1
p. 367
p. 373
p.396
p.410
In equation for mA: replace 3.09x106 with 1.6x109 and 4236 with 6276
p. 412
p. 499
Under heat transfer coefficients: "y" units in first row should read Watts m-2 K-1
ERRATA.......................................
[Second Printing]
p. 92
Figure 4-1: The label on the gas side of the film should read "BULK GAS"
p.91
In the last equation in Table 4-1, the minus sign should be replaced by an equal sign
p. 105
p. 144/44
Negative signs should be placed in front of P in the bottom two equations on page
144; The signs in front of P in the two terms in the last equation on p. 145
shouldeach be reversed
p. 227
The negative sign should be removed from the right hand side of Equation (8.20)
p. 265
p. 267
It should be stated that Equation (10.16) is for the assumption of a "flat" profile
p. 268
p. 272
p. 290
The length parameter in the denominator of the equation at the top of the page should
be upper case L
p. 295
p. 302
p. 303
p. 306
The first term in the last line in Example 11.1 should read: PW = 7.67 x 107
p. 307
p. 313
p. 314
Change values in the Table as follows: 2.38 should be 0.238, .09 should be .019
p. 316
p. 317
p. 319
p. 320
p. 323
p. 325
Example 11-4; the viscosity ratio should be raised to the 0.1 power (NOT 0.2)
p. 326
p . 327
p. 328
Below Eq (11.40). The Reynolds number criterion should read: > 1000
p. 330
Problem 11-5: the statement: "0.5 hp motor", should be deleted. The pipe is a 2"
schedule 40, NOT a 1" schedule 40
p. 332
p. 333
Problem 11-13: Should read - "of gaseous cumene at 0.22 Mpa and 280 C"
p. 347
The last term in Equation (12.21) is missing the factor, 0.87 ( 4 in Table 12-3)
p. 358
Eq. (12.37) should be on the line ABOVE Condensation on Vertical Tubes - Laminar
Film
p. 365
In Eq. (12.48), NT should read, NTB, which is the number of tubes in the "baffle"
window
p. 367
p. 373
p. 381
In the middle of the page, should read
p.396
p.410
In equation for mA: replace 3.09x106 with 1.6x109 and 4236 with 6276
p. 412
p. 486
ERRATA.......................................
[First Printing]
p. 15
p. 69
MATLAB Command File name must be COOLFIN (not COOL). Semicolons needed
after each of last 2 statements in Command File.
p. 72
Negative signs should be placed in front of RA in the second and third equations on
this page.
p. 77
p. 91
Negative signs missing in the relative velocities for ji and JI; In the last equation in
Table 4-1, the minus sign should be replaced by an equal sign
p. 92
Figure 4-1: The label on the gas side of the film should read "BULK GAS"
p. 93
In EXAMPLE 4-1:
In EXAMPLE 4-1: A1 = - RHS of Eq.
p. 99
In line just prior to Eq. (4.23), Equations (3.7) - (3.9) should be replaced with
Equations (3.16) - (3.18)
p. 105
p. 121
Delete the words : in the in the first line of Problem 4-15 (a)
p. 135
p. 144/145
Negative signs should be placed in front of P in the bottom two equations on page
144; The signs in front of P in the two terms in the last equation on p. 145
shouldeach be reversed
p. 166
p. 167
Next to last sentence: the value of the collision integral should be 1.341
Example 6-1: The equation at the top of the page should read:
p. 168
p. 227
The negative sign should be removed from the right hand side of Equation (8.20)
p. 250
p. 265
p. 267
It should be stated that Equation (10.16) is for the assumption of a "flat" profile
p. 268
p. 272
p. 290
The length in the denominator of the equation at the top of the page should be upper
case L
p. 295
p. 302
p. 303
p. 306
The first term in the last line in Example 11.1 should read: PW = 7.67 x 107
p. 307
p. 313
p. 314
Change values in the Table as follows: 2.38 should be 0.238, .09 should be .019
p. 316
p. 317
p. 319
p. 320
p. 323
p. 325
Example 11-4; the viscosity ratio should be raised to the 0.1 power (NOT 0.2)
p. 326
p. 327
p. 328
Below Eq (11.40). The Reynolds number criterion should read: > 1000
p. 330
Problem 11-5: the statement: "0.5 hp motor", should be deleted. The pipe is a 2"
schedule 40, NOT a 1" schedule 40
p. 332
p. 333
Problem 11-13: Should read - "of gaseous cumene at 0.22 Mpa and 280 C"
p. 347
The last term in Equation (12.21) is missing the factor, 0.87 ( 4 in Table 12-3)
p. 358
Eq. (12.37) should be on the line ABOVE Condensation on Vertical Tubes - Laminar
Film
p. 365
In Eq. (12.48), NT should read, NTB, the number of tubes in the "baffle" window
p. 367
p. 373
p. 381
In the middle of the page, should read
p.396
p.410
In equation for mA: replace 3.09x106 with 1.6x109 and 4236 with 6276
p. 412
p. 405
p. 451
p. 486