Académique Documents
Professionnel Documents
Culture Documents
S.L.
DOCUMENT DESCRIPTION
REV.
DATE
Covering Letter
16.08.2013
16.08.2013
Price Schedule
16.08.2013
Scope of supply
16.08.2013
Commercial terms
16.08.2013
CLIENT
PROJECT
RFQ.NO.
E-MAIL DTD.22.07.2013
DOC NO.
OurRef.No. :SQ/G/N/11561/
Date
:16.08.2013
M/s.HydrotechEnterprisesPvt.Ltd.,
No.706ITLTwinTowers(SeventhFloor)
NetajiSubhashPlace,RingRoadPitampura
Delhi110034
Phone :+911142240075
Email :hydrotechenterprises@gmail.com
KindAttn.
Subject
Reference
DearSirs,
: Mr.Khurana
: YourrequirementofRotaryAirBlowerforTashkentSewerageProjectinUzbekistan
: YourEmailenquirydtd.22.07.2013
Weacknowledgewiththanksthereceiptofyourabovecitedenquiry,regardingyourrequirementofAir
Blowersoffollowingspecification.
CAPACITY(M3/Hr.)
DISCHARGEPRESSURE(Bar)
INLETPRESSURE(Bar)
DIFFERENTIALPRESSURE(Bar)
:100004500
:1.67
:0.953
:0.717
4500020250
1.69
0.953
0.737
5400024300
1.65
0.953
0.691
Accordingly,wearepleasedtosubmitourcompetitiveoffer,consistingofthefollowingdocuments:
1.
2.
3.
4.
Technicaldatacummaterialofconstruction
Priceschedule
Scopeofsupply
Commercialterms
WehaveofferedouradvanceddesignTrilobeblowers.Theseareenergyefficientandhasmanytechnical
advantages,brieflylistedbelow:
TECHNICALADVANTAGES:
Lowerpowerconsumption,thustremendoussavingonpowerconsumption.
Lowertemperaturerise
Lowpulsations,thustheprocessplantgetspulsationfreeair
Highoperatingefficiencies
CompliancetothemoststringentInternationalstandardsAPI619/ISO10440/BS1571
Compliance to the European Standard of machinery directive, thus compiling to the safety and
hazardousrequirementsofEuropeanstandards.
Sixnos.ofbearingswhichincludestwoadditionalthrustbearing,thusthrustloadsaretakencare.
Computergeneratedrotorprofilesthushighvolumetricefficiencies.
TheblowershavesixstrokesasagainstfourstrokesinTwinlobe.
Muchlowervibrationthustroublefreeoperation.
Doubleactingmetallicseals
TheblowersareCEmarked.
Swam is today the countrys largest blower manufacturing company with blowers upto 65,000 M3/hr. with
over45000installation&presenceinover12countries.
SwamhasplantsequippedwithCNCmachinesandhavinginhousetestingfacility1200KWmotivepowerand
hasmanufacturingfacilityofover120Nos.ofblowerspermonth.Thereforeweassuretodelivertheblowers
withinthecommitted&agreedschedule.
Trust, you would find the offer to your satisfaction and inline of your requirement. Should you, however,
requireanyotherinformation/clarification,pleasefeelfreetocontactus.
Thankingyouandassuringyouourbestservices,weremain.
Yoursfaithfully,
ForSWAMPNEUMATICSPVT.LTD.
(C.P.Sharma)
Dy.G.M.Marketing
Encl:Asabove.
CLIENT
ENQ.NO.
ITEM
PROJECT
SQ/G/N/11561/
16.08.2013
0
TECHNICAL DATA
Blower model
RH-1150WCTR
RM3500ACTR
RH-4000ACTR
(M3/hr.)
10000-4500
45000-20250
54000-24300
Inlet pressure
(bar)
0.953
0.953
0.953
Discharge pressure
(bar)
1.67
1.69
1.65
Differential pressure
(bar)
0.717
0.737
0.691
Blower speed
(Approx.) for max.
capacity
(RPM)
980
600
580
Shaft Power
(BKW)
255
1290
1460
Recommended motor
(KW/RPM)
315/1000
1450/750
1650/750
Drive arrangement
Sealing system
MATERIAL OF CONSTRUCTION
Casing
End-covers
Rotor-lobes
Rotor shaft
Timing gears
The bearings are heavy-duty anti-friction Cylindrical Roller type of SKF/FAG makes.
OTHER SALIENT FEATURES
The blowers are fitted with sealing system of advance design and of fail proof
performance for oil free conveyance. The sealing system consists of Labyrinth seal
along with metallic centrifuge disc & neutral chamber.
The blowers design & construction is in compliance to international standards like
API-619 / BS-1571/ ISO-10440.
The air delivered is completely oil free.
The blower is low speed, ruggedly, built and is suitable for continuous operation and
requires very less maintenance.
For SWAM PNEUMATICS PVT.LTD.
CLIENT
ENQ.NO.
ITEM
PROJECT
SQ/G/N/11561/
16.08.2013
0
PRICE SCHEDULE
S.
N.
1)
2)
3)
DESCRIPTION
Extra
price
of
Acoustic
enclosure for sound reduction
below 85 dB(A) in free field
condition at 1m distance from
blower,
ex-works,
Noida,
unpacked
The cost of manufacturing,
design and supply of Rotary Air
Blower model RM-3500ACTR
complete with accessories as
indicated in scope of supply,
Ex-works, Noida, unpacked
Extra
price
of
Acoustic
enclosure for sound reduction
below 85 dB(A) in free field
condition at 1m distance from
blower,
ex-works,
Noida,
unpacked
The cost of manufacturing,
design and supply of Rotary Air
Blower model RH-4000ACTR
complete with accessories as
indicated in scope of supply,
Ex-works, Noida, unpacked
Extra
price
of
Acoustic
enclosure for sound reduction
below 85 dB(A) in free field
condition at 1m distance from
blower,
ex-works,
Noida,
unpacked
QTY.
REQD.
TOTAL
PRICE(RS.)
1,450,000.00 /-Each
02
Nos.
2,900,000.00
395,000.00 /-Each
02
Nos.
790,000.00
13,500,000.00 /-Each
03
Nos.
40,500,000.00
2,450,000.00 /-Each
03
Nos.
7,350,000.00
16,690,000.00 /-Each
04
Nos.
66,760,000.00
3,090,000.00 /-Each
04
Nos.
12,360,000.00
CLIENT
ENQ.NO.
ITEM
PROJECT
SQ/G/N/11561/
16.08.2013
0
SCOPE OF SUPPLY
Suction Silencer
Discharge Silencer
Non-return valve
Foundation bolts
Temperature Switch
Pressure Switch
CLIENT
ENQ.NO.
ITEM
PROJECT
SQ/G/N/11561/
16.08.2013
0
COMMERCIAL TERMS
PRICE
P. & F.
Would be extra @10% on order value for Sew Worthy export packing
FREIGHT
Extra actual
EXCISE DUTY
EDUCATIONAL
CESS
HS CESS
TAXES
Nil against Form H, otherwise C.S.T. would be charged @2% with form
C
40% advance with order and balance against proforma invoice before
dispatch or documents through bank. This, however, can be discussed.
7-11 months after receipt of your firm order with advance and approval
of drawings and other documents, whichever is later. This is normal
delivery and can be improved in case of urgent requirement and can be
phased in 2 or 3 lots depending on your project schedule. This is
however subject to force majure conditions.
The testing of equipment would be done at our works as per BS-1571
Part-II for determining capacity and pressure, prior to dispatch. Test
reports would be furnished. The charges for performance witness shall
be extra and would be separately furnished.
The equipment is guaranteed against manufacturing defects for 12
months from the date of supply. This is, however, subject to our
standard warrantee condition.
Our offer is valid for 60 days and thereafter, it is subject to our
confirmation in writing.
We can depute our engineer for supervision of commissioning if required
at extra and furnished on hearing from you.
We can arrange transit Insurance of the equipment if required at nominal
extra @1%.
PAYMENT TERMS
DELIVERY
INSPECTION &
TESTING
GUARANTEE
VALIDITY
COMMISSIONING
INSURANCE