82090

2/2 way valves


DVGW approval
G1/4 ... G1
Solenoid actuated diaphragm with forced lifting
High functional reliability
Short response time < 1 s
Valve operates without differential pressure
Solenoid interchangeable without tools
Operating pressure 0 to 8 bar

Technical features
Medium:
Neutral gases and liquid fuels
Operation:
Solenoid operated
Mounting:
Optional, preferably solenoid
vertical on top
Flow direction:
Determined

Port size:
G1/4 G 1
Operating pressure:
0 8 bar (0 116 psi)
Note:
Strainer with maximum mesh
size of 0,25 mm is necessary
upstream of the valve.

Fluid/ Ambient temperature:


0 ... +60C (+32 ... +140F)
Air supply must be dry enough
to avoid ice formation at
temperatures below
+2C (+35F).
EC-Type Examination Certificate
product ID-No.:
CE-0085CN0205 valve class A:
G 1/4 - G 3/4; B: G 1; valve group 2
Qualification approval:
EN 161 2011 and EN ISP 23553-1

Materials:
Body: Brass (CW617N)
Seat seal: NBR
Internal parts: Stainless steel,
PVDF, brass

2/2 way valves


Symbol

Orifice
(mm)

Size

2
1

Flow kv value *2)


(m3/h)

Operating pressure *1) Weight


(bar)
(kg)

Model
Solenoid in V d.c.

Model
Solenoid in V a.c.

G1/4

1.9

0 ... 8

0,8

8209000.9178.xxxxx

8209000.9179.xxxxx

G3/8

10

3,0

0 ... 8

0,8

8209100.9178.xxxxx

8209100.9179.xxxxx

G1/2

12

3,4

0 ... 8

0,9

8209200.9178.xxxxx

8209200.9179.xxxxx

G3/4

20

5,8

0 ... 8

1,0

8209300.9178.xxxxx

8209300.9179.xxxxx

G1

25

0 ... 8

1,3

8209400.9178.xxxxx

8209400.9179.xxxxx

xxxxx Please insert voltage and frequency codes see page 2


*1) for gases and liquid fluids up to 25 mm2/s (cSt)
*2) Cv-value (US) kv-value x 1,2

Option selector
Port size

820900..
Substitute

Frequency

Substitute

G 1/4

See table frequency codes

G 3/8

Voltage

G 1/2

See table Voltage codes

G 3/4

Solenoid system

G1

For 24 V d.c. and


24, 110 & 120 V a.c.

9178

For 230 V a.c. only

9179

11/12

Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.

xx
Substitute
xxx
Substitute

N/en/en 5.8.120.01

82090
Electrical details for all solenoid systems

Standard solenoid systems


Voltage and frequency codes 9178 * und 9179 * series
Code
Voltage

Code
Frequency

Voltage

Frequency

Power
consumption
Inrush *1)

Power
consumption
Hold *1)

Design

DIN VDE 0580

Voltage range

10%

Duty cycle

100% ED

Protection class

EN 60529 IP65

Socket

Form A acc. to DIN EN 175301-803 (included)

024

00

24 V d.c.

18 W

18 W

024

49

24 V a.c.

40 60 Hz

20 VA

20 VA

110

49

110 V a.c.

40 60 Hz

20 VA

20 VA

According to DIN VDE 0580 at coil temperature of +20C. In operation the power
consumption of the solenoid decreases by approx. 30%.

230

49

230 V a.c.

40 60 Hz

20 VA

20 VA

Note: AC solenoids have a DC rectifier integrated into the solenoid plug.

coil only

Additional solenoid systems

Solenoid systems 917x (voltage range)


Solenoid 9178

Solenoid 9179

ATEX category

Protection class

Solenoid

II2GD

EEx me II T3 T140 C

9191

Attention!
The conditions imposed on the Ex approvals lead to reduction of the permissible
standard temperature ranges in the cases of explosion protected solenoids.

24 ... 120 V

121 ... 250 V

Dimensions

Dimensions shown in mm

H1

Supply
port (R)

H1

Model

G1/4

44

104

92,5

60

12

8209000.917x

G3/8

44

104

92,5

60

12

8209100.917x

G1/2

44

108

94,5

67

14

8209200.917x

G3/4

50

115

99

80

16

8209300.917x

G1

62

124

103,5

95

18

8209400.917x

T
L

Warning
These products are intended for use in industrial fluid systems only.
Do not use these products where pressures and temperatures can
exceed those listed under Technical features.
Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other
applications not within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in
fluid power systems can fail in various modes.

N/en/en 5.8.120.02

The system designer is warned to consider the failure modes


of all component parts used in fluid power systems and to provide
adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
System designers must provide a warning to end users in
the system instructional manual if protection against
a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with
these products.

Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.

11/12

Vous aimerez peut-être aussi