fx-115W
fx-570W
fx-991W
Users Guide
Gua del usuario
Mode demploi
Bedienungsanleitung
Guida dellutilizzatore
ESFGI
ENGLISH
Removing and Replacing
the Calculators Cover
To Remove the cover
Grasp the top of the cover, and slide the unit out from the
bottom.
Safety Precautions
Be sure to read the following safety precautions before
using this calculator. Keep this manual handy for later reference.
Caution
This symbol is used to indicate information that can
result in personal injury or material damage if ignored.
Batteries
After removing the batteries from the calculator, put
them in a safe place where there is no danger of
them getting into the hands of small children and
accidently swallowed.
Keep batteries out of the reach of small children. If
accidently swallowed, consult with a physician immediately.
Never charge batteries, try to take batteries apart, or
allow batteries to become shorted. Never expose batteries to direct heat or dispose of them by incineration.
Misuse of batteries can cause them to leak acid that
can cause damage to nearby items and creates the
possibility of fire and personal injury.
Always make sure that a batterys positive k and
negative l sides are facing correctly when you
load it into the calculator.
Remove the batteries if you do not plan to use the
calculator for a long time.
Use only the type of batteries specified for this calculator in this manual.
E-1
Handling Precautions
Be sure to press the P button on the back of the cal
E-2
ture extremes.
Very low temperatures can cause slow display response,
total failure of the display, and shortening of battery life.
Also avoid leaving the calculator in direct sunlight, near
a window, near a heater or anywhere else it might become exposed to very high temperatures. Heat can
cause discoloration or deformation of the calculators
case, and damage to internal circuitry.
Avoid use and storage in areas subjected to large
amounts of humidity and dust.
Take care never to leave the calculator where it might
be splashed by water or exposed to large amounts of
humidity or dust. Such elements can damage internal
circuitry.
Never drop the calculator or otherwise subject it to
strong impact.
Never twist or bend the calculator.
Avoid carrying the calculator in the pocket of your trousers or other tight-fitting clothing where it might be subjected to twisting or bending.
Never try to take the calculator apart.
Never press the keys of the calculator with a ball-point
pen or other pointed object.
Use a soft, dry cloth to clean the exterior of the unit.
If the calculator becomes very dirty, wipe it off with a
cloth moistened in a weak solution of water and a mild
neutral household detergent. Wring out all excess moisture before wiping the calculator. Never use thinner, benzine or other volatile agents to clean the calculator. Doing so can remove printed markings and damage the
case.
E-3
Contents
Safety Precautions .......................................... 1
Handling Precautions ....................................... 2
Two-line Display ............................................... 5
Key Layout ........................................................ 6
Before Starting Calculations... ....................... 8
kModes .................................................................... 8
kInput Capacity ........................................................ 9
kMaking Corrections During Input ........................... 9
kReplay Function ..................................................... 9
kError Locator ........................................................ 10
kExponential Display Formats ............................... 10
kAnswer Memory ................................................... 10
Specifications ................................................ 39
Two-line Display
Key
Key Layout
Layout
< fx-570W >
Page
Page
25
Page
Page
17
11
Page
Page
11
20
11
21 17
M
21 17
15
16
15
15 29
27
29
16
15 29
HEX
10 BIN
16
11
14
21 24
r
arg
OCT
15
14 11
15
14 11
sin-1 D
cos-1 E
tan-1 F
14
24 11
14
20 11
11 11
Abs
11
11
11
21 17 21 17
M-
20
DT CL
11
11 19
INS
McI ScI
21 17
21 17
9
19
19
nPr
nCr
19 17
19 17
21 18
21 18
Pol(
19 17
OFF
DEC
30
24
MODE
16
15
11
Re<->lm
Page
CONV
Page
25
x! LOGIC
12
30 11
DISTR
16 29
30
12
Page
Page
REPLAY
ALPHA
Page
25
Page 18 24
Page
Page
12
SHIFT
16
16
Rnd
Ran#
16
15
DRG
Page
11
CONV
fx-100W:
15
E-6
10
y Rec(
13
20
Key Layout
< fx-991W >
Page
Page
25
Page
Page
Page
Page
11
20
11
21 17
M
21 17
16
15
15 29
16
15 29
HEX
10 BIN
16
11
14
21 24
r
arg
OCT
15
14 11
15
14 11
sin-1 D
cos-1 E
tan-1 F
14
24 11
14
20 11
11 11
Abs
M-
20
DT CL
11
11 19
INS
McI ScI
21 17
21 17
9
19
19
nPr
nCr
19 17
19 17
21 18
21 18
Pol(
Page
15
27
29
11
11
11
21 17 21 17
19 17
ON
DEC
30
24
MODE
16
15
11
Re<->lm
Page
CONV
DISTR
25
x! LOGIC
12
30 11
Page
Page
16 29
30
12
17
11
REPLAY
ALPHA
Page
25
Page 18 24
Page
Page
12
SHIFT
16
16
Rnd
Ran#
16
15
DRG
Page
11
CONV
fx-115W:
15
E-7
10
y Rec(
13
20
Mode
Name
Mode
Indicator
COMP
CMPLX
CMPLX
SD
SD
Calculation Modes
Normal calculations
Complex number
calculations
Standard deviation
calculations
Regression calculations
Base-n calculations
REG
REG
BASE-N b (binary)
o (octal)
d (decimal)
H (hexadecimal)
GRA
R
T
B
NORM1
NORM2
FIX
Fix
SCI
Sci
ENG
ENG
DEG
RAD
Grads
Display Modes
Exponential notation
(Canceling FIX and SCI
specification)
Number of decimal
place specification
Number of significant
digit specification
Exponential display range
specifications
Note!
Mode indicators appear in the lower part of the display,
except for the Base- n indicators which appear in the exponent part of the display.
The ENG mode cannot be selected while the calculator
is in the CMPLX or BASE-N mode.
E-8
You cannot set the angle unit or the display mode while
the calculator is in the BASE-N mode.
The COMP, CMPLX, SD, and REG modes can be used
in combination with the angle unit modes.
Be sure to check the current calculation mode (SD, REG,
COMP, CMPLX) and angle unit mode (DEG, RAD, GRA)
before beginning a calculation.
k Input Capacity
The memory area used for calculation input can hold 79
steps. Whenever you input the 73rd step of any calculation, the cursor changes from _ to k to let you know
memory is running low. If you still need to input more,
you should divide your calculation into two or more parts.
k Replay Function
Pressing r or e recalls the last calculation you performed. You can then make any changes you want in
the calculation and re-execute it.
Pressing t does not clear Replay memory, so you can
recall the last calculation even after you press t.
Replay memory is cleared whenever you start a new
calculation, change to another mode, or turn off power.
E-9
k Error Locator
Pressing r or e after an error occurs displays the
calculation with the cursor positioned at the location
where the error occurred.
NORM 1
With NORM 1, exponential notation is automatically used
for integer values with more than 10 digits and decimal
values with more than two decimal places.
NORM 2
With NORM 2, exponential notation is automatically used
for integer values with more than 10 digits and decimal
values with more than nine decimal places.
All of the examples in this manual show calculation results using the NORM 1 format.
k Answer Memory
Whenever you press = after inputting values or an expression, the calculated result is automatically stored in
Answer Memory. You can recall Answer Memory contents by pressing g.
Answer Memory can store up to 12 digits for the mantissa
and two digits for the exponent.
Answer Memory contents are not changed if the operation performed by any of the above key operations results in an error.
E-10
Basic Calculations
Use the COMP mode for basic calculations.
Example 1 : 3(5109)
3-R5eD9T=
1.5-08
Example 2 : 5(97)
5-R9+7T=
80.00
Memory Calculations
k Independent Memory
Values can be input directly into memory, added to
memor y, or subtracted from memory. Independent
memory is convenient for calculating cumulative totals.
Independent memory uses the same memory area as
variable M.
To clear independent memory (M), input 0 j 3.
Example:
23 9 32
53 6 47
) 45 2 90
(Total)
11
23 + 9 j 3
32.00
53 , 6 |
47.00
45 - 2 A {
90.00
03
11.00
k Variables
There are nine variables (A through F, M, X and Y), which
can be used to store data, constants, results, and other
values.
Use the following operation to delete data assigned to
all nine variables: A C =.
Use the following operation to delete data assigned to a
particular variable: 0 j 1. This operation deletes
the data assigned to variable A.
E-11
8.400
p 1 \ 28 =
6.900
Fraction Calculations
k Fraction Calculations
Use the COMP mode for fraction calculations.
Values are automatically displayed in decimal format
whenever the total number of digits of a fractional value
(integer numerator denominator separator marks)
exceeds 10.
Example 1 :
2
4
1
3
5
2C3 +1C 4C 5=
2 7 15.00
1
1.6
2
1 C 2 + 1.6 =
2.100
Example 2 :
k Decimal-to-Fraction Conversion
Example: 2.75 2
3
4
2.75 =
2.75
2 3 4.00
AB
11 4.00
k Fraction-to-Decimal Conversion
Example:
1
0.5 (Fraction Decimal)
2
1C 2=
E-12
1 2. 00
0.500
1 2. 00
Percentage Calculations
Use the COMP mode for percentage calculations.
Example 1 : To calculate 12% of 1500
1500 - 12 A v
180.00
75.00
2875.00
2625.00
160.00
E-13
15.00
k Trigonometric/Inverse Trigonometric
Functions
Example 1 : sin635241
q q q 1 R
00
S 63 I 52 I 41 I = 0.897859012
R
rad
3
q q q 2 T
Example 2 : cos
0.500
WRAx\3T=
rad
2
4
q q q 2 T
Example 3 : cos1
WAVRL2\2T=
0.78539816300
g\Ax=
0.2500
q q q 1 R
A g 0.741 =
36.5384457700
R
k Hyperbolic/Inverse Hyperbolic
Functions
Example 1 : sinh 3.6
M S 3.6 =
18.2854553600
Example 2 : sinh1 30
M A j 30 =
E-14
4.09462222400
1 2
FFF1 R
4 . 25 r
4.25 A v 2 (R ) = 243.5070629
R 1.23 =
0.08990511100
T 90 =
4.4998096700
Example 3 : e10
A U 10 =
22026.4657900
Example 4 : 101.5
A Q 1.5 =
31.622776600
2w 4=
16.00
Example 5 : 24
2 3 5
L2 +L3 -L 5=
Example 2:
5
5.28719690900
27
A D 5 + A D D 27 = 1.29002405300
(fx-100W/ fx-115W: D)
E-15
1.98864779500
Example 4: 12330 2
123 + 30 K =
1023.00
12 N =
1728.00
R3a,4aTa=
12.00
8Af=
40320.00
Example 5: 12 3
Example 6:
1
1 1
3
4
Example 7: 8!
AM=
0.66400
3Ax=
Example 9: 3
9.42477796100
(Specifies three
decimal places.)
200 \ 7 - 14 =
400.00
FFFF13
400.00000
Fix
200 \ 7 =
28.57100
- 14 =
400.00000
28.57100
AQ
28.57100
(Internal rounding)
E-16
- 14 =
399.99400
FFFF2 21 \3 =
3.301
Sci
k ENG Calculations
Example 1: To convert 56,088 meters to kilometers
56088 = J
56.088003
81.2503
Ak
AM
Ag
At
Am
AN
An
Ap
Af
Unit
103
106
109
1012
103
106
109
1012
1015
E-17
Symbol
k (kilo)
M (Mega)
G (Giga)
T (Tera)
m (milli)
(micro)
n (nano)
p (pico)
f (femto)
* For displayed values, the calculator selects the ENG symbol that makes the numeric part of the value fall within
the range of 1 to 1000.
* ENG symbols cannot be used when inputting fractions.
* The ENG mode cannot be used in combination with the
CMPLX, or BASE-N modes.
Performing any of the key operations in the above table
while you are not in the ENG mode inputs the exponential value in the Unit column (without inputting the ENG
symbol).
Example: 910 = 0.9 m (milli)
0.
FFFFF1
9 \ 10 =
ENG
9 1
900.
AP
J
0.9
9 1
900.
A F 2 P 60 T =
0o
1.00
R
1.73205080800
Af1P L3T=
E-18
2.00
T
0 o 1.04719755100
k Permutation
Example: To determine how many different 4-digit values can be produced using the numbers 1 through 7
Numbers cannot be duplicated within the same 4-digit
value (1234 is allowed, but 1123 is not).
7Am 4=
840.
k Combination
Example: To determine how many different 4-member
groups can be organized in a group of 10 individuals
10 A n 4 =
210.
Statistical Calculations
k Standard Deviation (SD Mode)
Press F F 1 to enter the SD Mode for statistical
calculations using standard deviation.
Data input always starts with A m = to clear statistical memory.
Input data is used to calculate values for
2
n, x, x2, o, n and n-1 which you can 0 1 x
0 2 x
recall using the key operations noted
0k n
nearby.
AM o
A A n
A N n-1
E-19
SD
52.00
A N = 1.40788595300
A A = 1.31695671900
(Arithmetic Mean o)
AM =
53.37500
(Number of Data n)
0k
8.00
x)
0H
427.00
0G
22805.00
(Sum of Values
x 2)
P ( Q ( R ( t
1 2
Q(t)
E-20
R(t)
A D 1 ( P( ) -0.28 F =
0.38974
0 G x 2 A N
0 H x A l
0k
n Ad
0 h y 2 A c
0 n y A q
0 o xy A w
0 M x 3 A e
0 x x2y A u
0 y x 4 A O
AM
o Ab
A A xn
xn-1
p
yn
yn-1
Regression coefficient A
Regression coefficient B
Regression coefficient C
Correlation coefficient r
m
n
Linear Regression
The regression formula for linear regression is: y A Bx.
E-21
Atmospheric
Pressure
10C
15C
20C
25C
30C
1003 hPa
1005 hPa
1010 hPa
1011 hPa
1014 hPa
qq21
A m = (Memory Clear)
10 P 1003 S 15 P 1005 S
20 P 1010 S 25 P 1011 S
30 P 1014 S
30.00
REG
(Regression Coefficient A)
Aq=
997.400
(Regression Coefficient B)
Aw=
0.5600
(Correlation Coefficient r )
AJ=
0.98260736800
18 A b
1007.4800
1000 A O
4.64285714300
Quadratic Regression
The regression formula for quadratic regression is:
y = A + Bx +Cx2.
Input data using the following key sequence.
< x-data> P <y-data> S
Example:
xi
yi
29
50
74
103
118
1.6
23.5
38.0
46.4
48.0
FF2r3
Am=
29 P 1.6 S 50 P 23.5 S
74 P 38.0 S103 P 46.4 S
118 P 48.0 S
118.
REG
(Regression Coefficient A)
A q = -35.59856934
(Regression Coefficient B)
Aw=
(Regression Coefficient C)
A e = -6.71629667-03
1.495939413
(y when x i = 16)
16 A b -13.38291067
(x 1 when yi = 20)
20 A O
47.14556728
(x 2 when yi = 20)
AO
175.5872105
E-23
Example: (2 + 3i) + (4 + 5i )
Enter CMPLX Mode F 2
R2+3iT+
R4+5iT=
6.
Real number part
Ar
8. i
Imaginary number part
AAR 3+4 iT =
5.
CMPLX
A a R 3 + 4 i T = 53.13010235
Formula Memory
Formula memory lets you input a single formula in
memory, and then input values for the formula's variables to calculate results.
E-24
pypupxK+
3 p x , 12
C
Store it in memory.
Input a value for its variable.
Y= X 2 +3 X-12
0.
X?
0.
7=
58.
X?
7.
8=
76.
CONV
CONV 1
31 i n
cm
31 i n
cm
0.
=
E-25
78.74
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
Conversion Pair
Number
Conversion Pair
in cm
cm in
ft m
m ft
yd m
m yd
mile km
km mile
n mile m
m n mile
acre m2
m2 acre
r
gal (US) r
r gal (US)
r
gal (UK) r
r gal (UK)
pc km
km pc
km/h m/s
m/s km/h
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
oz g
g oz
lb kg
kg lb
atm Pa
Pa atm
mmHg Pa
Pa mmHg
hp kW
kW hp
kgf/cm2 Pa
Pa kgf/cm2
kgfm J
J kgfm
lbf/in2 kPa
kPa lbf/in2
F C
C F
J cal
cal J
Example: To determine how much total energy a person weighing 65kg has (E = mc 2)
65 L
28
CONST
CONST28
65 Co
0.
65 Co 2
0.
65 Co 2
= 5.841908662 18
Scientific Constant Table
Based on ISO Standard (1992) data and CODATA Bulletin
63 (1986) data.
Number
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
Constant Name
proton mass
neutron mass
electron mass
muon mass
Bohr radius
Planck's constant
nuclear magneton
Bohr magneton
Planck's constant, rationalized (h-bar)
fine-structure constant
classical electron radius
electron Compton wavelength
proton gyromagnetic ratio
proton Compton wavelength
neutron Compton wavelength
Rydberg constant
atomic mass unit
proton magnetic moment
electron magnetic moment
neutron magnetic moment
muon magnetic moment
Faraday constant
E-27
Symbol
mp
mn
me
m
a0
h
N
B
re
c
p
cp
cn
R
u
p
e
n
Number
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Constant Name
elementary charge
Avogadro constant
Boltzmann constant
molar volume of ideal gas
molar gas constant
speed of light in vacuum
first radiation constant
second radiation constant
Stefan-Boltzmann constant
permittivity of vacuum
permeability of vacuum
magnetic flux quantum
standard acceleration of gravity
astronomical unit
parsec
Celsius temperature
Newtonian constant of gravitation
standard atmosphere
Symbol
e
NA
k
Vm
R
C0
C1
C2
0
0
0
g
AU
pc
t
G
atm
Base-n Calculations
In addition to decimal values, calculations can be performed using binary, octal and hexadecimal values.
You can specify the default number system to be applied to all input and displayed values, and the number
system for individual values you input.
You cannot use scientific functions in binary, octal, decimal, and hexadecimal calculations. You cannot input values that include decimal part and an exponent.
If you input a value that includes a decimal part, the unit
automatically cuts off the decimal part.
Negative binary, octal, and hexadecimal values are produced by taking the two's complement.
You can use the following logical operators between
values in Base-n calculations: and (logical product), or
(logical sum), xor (exclusive logical sum), xnor (exclusive logical sum negation), Not (negation), and Neg (minus).
E-28
x
x
x
x
x
x
x
1111111111
0111111111
7777777777
3777777777
2147483647
FFFFFFFF
7FFFFFFF
FF3b
0.
101112 + 110102
0.
110001.
FF3o
0.
l l l 4 (o) 76548 \
l l l 1 (d)1210
0.
516.
0.
12016 l 2 (or)
l l l 3 (b)11012
0.
12d.
E-29
Integration Calculations
The following four inputs are required for integration calculations: a function with the variable x; a and b, which
define the integration range of the definite integral; and
n, which is the number of partitions (equivalent to N = 2n)
for integration using Simpsons rule.
d expression P a P b P n T
Use the COMP mode for integration calculations.
Example: To calculate:
(2 x2 + 3x + 8) dx
d 2p xK+3 px+
8P 1P5 P6 T
0.
= 150.6666667
Note!
2.258
AO
21528.8
0.
432431.2
E-30
Technical Information
k When you have a problem......
If calculation results are not what you expect or if an error
occurs, perform the following steps.
1. F 1 (COMP mode)
2. F F F 1 (DEG mode)
3. F F F F 3 1 (NORM 1 mode)
4. Check the formula you are working with to confirm it is
correct.
5. Enter the correct modes to perform the calculation and
try again.
< fx-570W/ fx-100W >
If the above steps do not correct your problem, press the
P button (see page 35 or 36) on the back of the calculator
to reset it. Pressing the P button deletes all data stored
in calculator memory. Make sure you always keep written
copies of all important data.
< fx-991W/ fx-115W >
If the above steps do not correct the problem, press the
5 key. The calculator performs a self-check operation and
deletes all data stored in memory if any abnormality is
detected. Make sure you always keep written copies of all
important data.
k Error Messages
The calculator is locked up while an error message is on
the display. Press t to clear the error, or press e or r
to display the calculation and correct the problem. See
Error Locator on page 10 for details.
Ma ERROR
Cause
Calculation result is outside the allowable calculation
range.
Attempt to perform a function calculation using a value
that exceeds the allowable input range.
E-31
Stk ERROR
Cause
Capacity of the numeric stack or operator stack is exceeded.
Action
Simplify the calculation. The numeric stack has 10
levels and the operator stack has 24 levels.
Divide your calculation into two or more separate parts.
Syn ERROR
Cause
Attempt to perform an illegal mathematical operation.
Action
Press e or r to display the calculation with the
cursor located at the location of the error. Make necessary corrections.
Arg ERROR
Cause
Improper use of argument
Action
Press e or r to display the location of the cause of
the error and make required corrections.
k Order of Operations
Calculations are performed in the following order of precedence.
1 Coordinate transformation: Pol (x, y), Rec (r , )
Integrations: dx
2 Type A functions:
With these functions, the value is entered and then the
function key is pressed.
x2, x1, x!,
3 Powers and roots: xy, x
E-32
4 a b/c
5 Abbreviated multiplication format in front of , memory
name, or variable name: 2, 5A, A etc.
6 Type B functions:
With these functions, the function key is pressed and
then the value is entered.
3
,
, log, In, ex, 10x, sin, cos, tan, sin 1 , cos1,
tan1, sinh, cosh, tanh, sinh 1, cosh1, tanh1, ()
7 Abbreviated multiplication format in front of Type B
functions: 2 3, Alog2 etc.
8 Permutation and combination: nPr , nC r
9 ,
0 ,
* Operations of the same precedence are performed from
right to left. exIn
120 e x{In(
120)}
Other operations are performed from left to right.
* Operations enclosed in parentheses are performed first.
k Stacks
This calculator uses memory areas, called stacks, to temporarily store values (numeric stack) and commands (command stack) according to their precedence during calculations. The numeric stack has 10 levels and the command
stack has 24 levels. A stack error (Stk ERROR) occurs
whenever you try to perform a calculation that is so complex that the capacity of a stack is exceeded.
E-33
k Power Supply
The type of battery you should use depends on the model
number of your calculator.
< fx-991W/ fx-115W >
The TWO WAY POWER system actually has two power
supplies: a solar cell and a G13 Type (LR44) button battery. Normally, calculators equipped with a solar cell alone
can operate only when relatively bright light is present.
The TWO WAY POWER system, however, lets you continue to use the calculator as long as there is enough light
to read the display.
E-34
Screw
Screw
E-35
P button
Screw
Screw
P button
E-36
k Input Ranges
Internal digits: 12
Accuracy: As a rule, accuracy is 1 at the 10th digit.
Functions
sinx
Input Range
DEG 0 x 4.4999999991010
RAD 0 x 785398163.3
GRA 0 x 4.4999999991010
cosx
tan x
sin1x
cos1x
0 x 1
tan1x
0 x 9.9999999991099
sinhx
coshx
0 x 230.2585092
sinh x
0 x 4.9999999991099
cosh1x
tanhx
tanh1x
0 x 9.99999999910-1
log x/ln x 0 x
10 x
9.9999999991099 x 99.99999999
ex
x
x2
1/x
3
x
x!
9.9999999991099 x 230.2585092
0 x 1 10100
x 1 1050
x 1 10100 ; x G 0
x 1 10100
0 x 69 (x is an integer)
E-37
Functions
Input Range
xy
a b/c
SD
(REG)
a, b, c 110100
0 b, c
x110100
Decimal Sexagesimal Conversions
00 0000 x 9999990 590
x0: 110100ylogx100
x0: y0 1
x0: yn, 2n+1 ( n is an integer)
However: 110 100 ylogx100
y0: x G 0
1101001/x logy100
y0: x0
1
y0: x2n1, n (n G 0; n is an integer)
However: 110 100 1/x logy100
Total of integer, numerator, and denominator
must be 10 digits or less (including division
marks).
x 11050
y 11050
n 110100
xn, yn, o, p
A, B, r : n G 0
xn1, yn1 : n G 0, 1
E-38
Specifications
Power Supply:
fx-100W: Single AA-size battery (R6P (SUM-3))
fx-570W: Single G13 Type button battery (LR44)
fx-115W/ fx-991W:
Solar cell and a single G13 Type button battery (LR44)
Battery Life:
fx-100W: Approximately 17,000 hours continuous display of flashing cursor.
Approximately 2 years when left with power
turned off.
fx-570W: Approximately 12,000 hours continuous display of flashing cursor.
Approximately 3 years when left with power
turned off.
fx-115W/ fx-991W:
Approximately 3 years (1 hour use per day).
Dimensions:
fx-100W: 19.2(H) 76(W) 164(D) mm
3/4 (H) 3(W) 67 /16 (D)
fx-115W/ fx-570W/ fx-991W:
10(H) 76(W) 150(D) mm
3/8 (H) 3(W) 57 /8(D)
Weight:
fx-100W: 114 g (4 oz) including battery
fx-115W/ fx-570W/ fx-991W: 85 g (3 oz) including battery
Power Consumption: 0.0001W
Operating Temperature: 0C ~ 40C (32F ~ 104F)
E-39