Académique Documents
Professionnel Documents
Culture Documents
Tpicos
Harmnicos
Estudo de caso
ABB Group
September 16, 2015 | Slide 2
Consideraes finais
Harmnicos
Harmnicos
O que so?
Sistemas eltricos
ABB Group
September 16, 2015 | Slide 4
Harmnicos pares
Harmnicos mpares
Harmnicos triplos
Tenso;
Corrente.
Harmnicos
O que so?
Forma de onda
distorcida devido aos
harmnicos presentes
10
15
20
-500
-1000
-1500
-2000
Total
ABB Group
September 16, 2015 | Slide 5
25
30
35
Harmnicos
O que so?
Decomposio da
forma de onda
distorcida em ondas
mltiplas da
fundamental
10
15
20
25
-500
-1000
-1500
-2000
ABB Group
September 16, 2015 | Slide 6
Total
Fundamental
5 harmnica
7 harmnica
11 harmnica
13 harmnica
30
35
Harmnicos
O que produz?
ABB Group
September 16, 2015 | Slide 7
Harmnicos
Quais problemas so gerados?
TENSES & CORRENTES DE LINHA EM UMA ESTAO DE
BOMBEAMENTO
750
500
Volts
250
0
-250
-500
-750
3000
2000
Amps
1000
0
-1000
-2000
-3000
10:25:43.72
10:25:43.73
CHA Volts
10:25:43.74
CHB Volts
10:25:43.75
CHC Volts
CHA Amps
10:25:43.76
CHB Amps
10:25:43.77
CHC Amps
10:25:43.78
Harmnicos
Quais problemas so gerados?
Trip de disjuntores e queima de fusveis
Aumento da corrente RMS: efeito trmico
Aumento do pico da corrente: efeito dinmico
Efeito pelicular
Cabos
Interferncias eletromagnticas
Equipamentos hospitalares
Queima de capacitores Baixa impedncia e ressonncia
ABB Group
September 16, 2015 | Slide 9
Balanceamento
de carga
Mitigao
harmnica
Compensao
reativa
PQF
ABB Group
September 16, 2015 | Slide 11
IH carga
IH filtro
PQF
IH filtro = - IH carga
ABB Group
September 16, 2015 | Slide 12
PQFI
PQFM
690V: 100A
3P3W, 50/60Hz
3P3W, 50/60Hz
Auto-portante
Auto-portante
Month
YYYY
DD,
PQFS
Instalaes comerciais
Montagem em parede
Tecnologia de IGBTs;
Design compacto;
Chaveamento PWM;
Modularidade;
Conexo trifsica a 3 ou 4
fios;
Sem riscos de
ressonncias.
20 ordens harmnicas
simultneas;
Diferentes modos de
operao
Funo de auto-restart
ABB Group
September 16, 2015 | Slide 14
PQFS a 4 fios: 15
ordens simultneas.
2 a 50 ordens
harmnicas;
Compensao reativa;
Balanceamento de fases;
Protees internas;
slave
slave
slave
Unit4
PQF
PQF
X X X X
Unit1
Unit2
slave
Unit4
PQF
Unit3
Falha na 3 unidade:
PQF
PQF
PQF
master
ABB Group
September 16, 2015 | Slide 15
Unit2
Unit2
PQF
Unit4
Falha na 3 unidade:
Unit1
slave
Unit3
Unit1
Falha na 1 unidade:
PQF
Unit2
PQF
master
PQF
Falha na 1 unidade:
master
PQF
Unit4
PQF
Unit3
Redundncia limitada
master
Unit2
PQF
Unit1
PQF
master
Redundncia total
Unit4
Filtragem
Erros de medio
Preciso da filtragem
Custo do TC
ABB Group
September 16, 2015 | Slide 16
Malha aberta
Malha fechada
No controlado
Controlado
Impacto significativo
Imune
Baixa
Alta
Elevado
Mdio
Control point
CT : x/5A
PQF
VFD
VFD
VFD
VFD
Other loads
spare
THDI = ? unknown
Total loads = ? Unknown
Pass/fail regulation = ? Unknown
CT
CT:x/1A
AF?
VFD
VFD
VFD
CT
VFD
CT
VFD
CT
VFD
spare
Other loads
SCT
ABB Group
September 16, 2015 | Slide 17
Accuracy drop !
Future extent ion =?
Aumento da
carga no filtro
Reduo da
carga no filtro
ABB Group
September 16, 2015 | Slide 18
Filtragem
segundo a curva
Filtragem at os
limites do
hardware
Estudo de caso
Estudo de caso
Indstria
Motores CC
Drives DC
ABB Group
September 16, 2015 | Slide 20
Elevado contedo de
5, 7, 11, 13, ... (6
pulsos)
Baixo fator de potncia:
0,65i
THDv: 12,6%
Banco de capacitores
existente: 1300 kVAr,
dessintonizado
Estudo de caso
Espectro harmnico de tenso
Espectro harmnico de tenso SEM FILTRO
Fonte: Medies ABB
14.00
12.00
10.00
8.00
6.00
4.00
2.00
Ordem harmnica
ABB Group
September 16, 2015 | Slide 21
31
29
27
25
23
21
19
17
15
13
11
THDv
0.00
Estudo de caso
Espectro harmnico de corrente
Espectro harmnico de corrente SEM FILTRO
Fonte: Medies ABB
700.00
600.00
500.00
400.00
300.00
200.00
100.00
Ordem harmnica
ABB Group
September 16, 2015 | Slide 22
30
28
26
24
22
20
18
16
14
12
10
0.00
Estudo de caso
Requisitos do cliente
ABB Group
September 16, 2015 | Slide 23
Estudo de caso
Soluo proposta pela ABB
Engenharia de aplicao
Realizao de
medies em campo
Especificao do
equipamento
Unidade master de
450A
Ordens harmnicas
selecionadas
ABB Group
September 16, 2015 | Slide 24
Estudo de caso
Soluo proposta pela ABB Diagrama unifilar
440V, 60Hz
PQFI
900A
ABB Group
September 16, 2015 | Slide 25
CARGA
Drives
DC
Banco de
capacitores
1300kVAr
dessintonizado
Estudo de caso
Soluo proposta pela ABB Resultados
Requisitos
Complementares
No incidncia de multas
ABB Group
September 16, 2015 | Slide 26
Correntes harmnicas
Potncia reativa
Estudo de caso
Espectro harmnico de tenso Com filtro
Espectro harmnico de tenso COM FILTRO
Fonte: Medies ABB
4.5
4
3.5
3
2.5
2
1.5
1
0.5
THDv
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
Ordem harmnica
ABB Group
September 16, 2015 | Slide 27
Estudo de caso
Espectro harmnico de corrente Com filtro
Espectro harmnico de corrente COM FILTRO
Fonte: Medies ABB
100.00
90.00
80.00
70.00
60.00
50.00
40.00
30.00
20.00
10.00
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
0.00
Ordem harmnica
ABB Group
September 16, 2015 | Slide 28
Consideraes finais
Hotis,
bancos, data
centers
Trat. de gua
ABB Group
September 16, 2015 | Slide 29
Grficas
Mquinas de
papel
Offshore
Ski lifts
Centrfugas
Propulso
Guindastes
Telecom.
Petroqumica
Mquinas de
enrolar
Compressores
Consideraes finais
ABB Group
September 16, 2015 | Slide 30
Filtragem harmnica
Compensao reativa
Balanceamento de cargas
Aplicaes at 690V
Estudo de caso
Reduo do THDv
ABB Group
September 16, 2015 | Slide 31