Vous êtes sur la page 1sur 92

Cooling Towers

AT | UT | USS
Advanced Technology (AT) Series
The Industrys Smartest Induced Draft, Counterflow Cooling Towers

i
*Mark owned by the Cooling Technology Institute

EVAPCO is more than a name.

Its a pledge to make everyday life easier, more comfortable, more


reliable, and more sustainable for people everywhere. How do we
fulfill on that promise? Its simple.
We never stop innovating.
At EVAPCO, we dont just talk about innovation. Its ingrained in
our workflow. Guided by our annually developed R&D plans, we
set out every day to find groundbreaking solutions that transform
the way the world works for the better. Its why we have more than
25 patents worldwide in the last 10 years alone.
We craft exceptionally built solutions.
As an employee-owned company, we are loyal. We demand
excellence of one another. And we take pride in our work. Together,
we make up one of the most experienced teams of engineers and
craftsmen in the industry. This translates into solutions that are always
exceptionally built. No one will deliver higher quality for you.

Get to Know EVAPCO

The global innovator in heat transfer


solutions
Serving the commercial HVAC, industrial
refrigeration, power generation, and
industrial processing markets
Founded in 1976
Employee-owned
20 facilities in 10 countries
More than 170 sales offices in 51 countries

Learn More Now.

Visit evapco.com to view complete product


specs, download product catalogs, and more.

We guarantee performance.
Every EVAPCO solution is put through rigorous research and
testing to deliver maximum efficiency and reliability. But we dont
stop there. We also lead the industry in independent, third-party
performance certifications. These certifications guarantee our
performance metricsso that you can plan your projects with
complete peace of mind.
We protect the environment.
Innovation and environmental sustainability go hand-in-hand at
EVAPCO. From sound reduction to water conservation to chemical
elimination, we are constantly developing new technologies that
deliver the ultimate operating advantages for our clients
and protect the planet for every generation that comes after us.

We are EVAPCOthe team you can count on for life.

The Advanced Technology Series:


The Industrys Smartest Cooling Towers

Crafted from decades of engineering know-how, the Advanced Technology (AT) cooling tower series from EVAPCO
features state-of-the-art induced draft, counterflow technology to deliver superior operating advantages in any climate.
From performance to maintenance, they simply work smarter.

3 Advanced Technology Options. More Possibilities.

Available in 60 cross sections and a capacity range of 33 to 5,141 nominal tons (144 to 22,596 kW).
See page 23 for model-by-model dimensions.
AT The original compact, low-horsepower, induced draft, axial fan solution for all
outdoor applications.
UT All of the benefits of the AT design, built with EVAPCOs Super-Low-Sound Fan
for sound-sensitive applications. See page 18 to learn more.
USS All-stainless-steel AT construction for maximum corrosion resistance, ideal for
coastal and other corrosive environments. See page 18 to learn more.
Hot Saturated Discharge Air

Principle of Operation
Warm water from the heat source is pumped to the water distribution
system at the top of the tower. The water is distributed over the wet deck
fill by means of large opening EvapJet nozzles. Simultaneously, air is
drawn in through the air inlet louvers at the base of the tower and travels
upward through the wet deck fill opposite the water flow. A small portion of the water is evaporated which removes the heat from the remaining water. The warm moist air is drawn to the top of the cooling tower by
the fan and discharged to the atmosphere. The cooled water drains to
the basin at the bottom of the tower and is returned to the heat source.

Drift
Eliminators
Hot
Water
In

Cool
ool
Dry
Dry
Entering
erin
ng
Air
Air
Cooled
o
Water
Out

Table of Contents
The Advanced Technology Tower at a Glance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Series Design Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
POWER-BAND Belt Drive System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Easy Maintenance Basin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Optional Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ultra-QuieT (UT) Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Ultra Stainless Steel (USS) Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Additional Resources: Specifying Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
EVAPCO Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Engineering Data & Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

22

The Advanced Technology Series at a Glance

Totally Enclosed Fan Motors


Motors positioned for easy accessibility and extended serviceability
Assures long life
Energy efficient/inverter capable motors supplied as standard
Optional space heaters available to eliminate condensation while idle

Louver Access Door


Hinged access panel with quick release mechanism
Allows easy access to perform routine maintenance
and inspection of the makeup assembly, strainer
screen, and basin
Standard on models with louvers 5 feet and taller

Easy Field Assembly


New field assembly seam design ensures easier
assembly and reduced potential for field seam leaks
Self-guided channels guide the fan casing section into
position, improving the quality of the field seam
Eliminates up to 66% of fasteners compared to old design

US Patent No. 7,927,196

WST Air Inlet Louvers (Water and Sight Tight)


Easily removable for access
Framed in same material as tower basin
Improved design to keep sunlight outpreventing
biological growth
Keeps water in while keeping dirt and debris out

EVAPCO Power-Band Drive System


Easy-maintenance, heavy-duty drive system
Standard heavy-duty pillow-block bearings with a minimum L10 life of 75,000 hours
Extended lube lines
External motor/belt adjustment
Solid-back multigroove belts and totally enclosed motors are standard

*International Building Code


**Office of Statewide Health Planning and Development
***Mark owned by the Cooling Technology Institute

IBC* & OSHPD** Designs


All standard models meet IBC requirements
Upgraded designs for high seismic and wind load areas
Upgraded designs can also be used for projects requiring OSHPD approval
US Patent Nos.7,938,373 and 7,963,492

Optional Motor Davit & Working Platform


Motor davit and bracket option for easy motor and fan removal
Also available for gearbox removal
Platform and ladder arrangement available as an option
Provides a robust self-supporting working surface for the service mechanic

EvapJet nozzle

Water Distribution System


EvapJet nozzles provides thermal performance gain
Non-corrosive PVC construction
Large orifice nozzles prevent clogging and are threaded for easy
removal and positive positioning
Each nozzle provides a large uniform spray pattern
System branches have threaded end caps to assist with debris removal

Clean Pan Sloped Basin Design


Designed to completely drain the cold water basin
Helps prevent buildup of sediment and biological film
Eliminates standing water after drain down (See details
of design on page 9)

***

The EVAPCO Performance Guarantee


CTI Certified | IBC Compliant | ASHRAE 90.1 Compliant
Every Advanced Technology product is rigorously thermal performance tested by EVAPCO
and then independently certified by the Cooling Technology Institute (CTI) so you know youre
getting a solution thats guaranteed to get the job done.

Innovative Design Features

With EVAPCO, you get a partner you can count on to keep you at the cutting edge of your field. Thats because we build
innovation into every HVAC solution that we deliver to you. Here are just some of the game-changing features youll find
in the Advanced Technology cooling tower series.

Optimum Design for Freezing Climates


The Advanced Technology cooling tower series features
a totally encased wet-deck fill which inhibits direct exposure to the elements, as well as a bonded-block structure
with bottom supports to provide additional support
should ice form. On top of that, the counterflow designs
even-temperature gradient ensures all water is cooled to
the same temperature. Together, these smarter design
elements make the Advanced Technology series the ideal
solution for severe climates.

EVAPAK Fill (US Patent 5,124,087)


EVAPAK fill is specially designed to induce a highly turbulent mix of air and water for superior heat transfer. Special
drainage tips allow high water loadings without excessive
pressure drops.
EVAPAK is constructed of inert polyvinyl chloride (PVC),
so it will not rot or decay. It can also withstand water temperatures of 130 F/55 C. (An option for higher water
temperatures is also available. Consult your EVAPCO
representative to learn more.)
The bottom support of the fill section, combined with the
unique way in which EVAPAKs cross-fluted sheets are
bonded together, greatly enhances the fills structural integrity, making it usable as a working platform for internal access
to the fan and drive system.
EVAPAK is also self-extinguishing with a flame spread rating
of 5 per ASTM-E84-81a.
High-Efficiency Drift Eliminators (US Patent 6,315,804)
EVAPCOs extremely efficient drift eliminator system removes
entrained water droplets from the air stream, limiting the drift
rate to less than 0.001% of the recirculating water rate in most
instances. This saves valuable water and enables you to place
your cooling tower in areas where minimum water carryover
is critical, such as parking lots.
The drift eliminators are constructed of inert PVC, which
effectively eliminates corrosion of these vital components.
They are assembled in sections to facilitate easy removal for
inspection of the water distribution system.

Sunlight

Air Intake

Smooth Flow Fans


Smooth flow axial propeller fans come standard on all
Advanced Technology series cooling towers. Fan
construction is dependent on unit size:
4-foot-wide: Fiberglass-reinforced polypropylene (PPG)
wide chord blades with die-cast aluminum hub
Over 4 feet: 100% aluminum alloy
All fans are statically balanced and installed in a closely
fitted cowl with venturi air inlet for maximum efficiency.
Fan screens are constructed of galvanized steel or
optional type 304 stainless steel, and have steel frames
bolted to the fan cowl.
Low sound and super low sound fan options are also
available. See page 15 to learn more.
Pressurized Water Distribution System
The Advanced Technology series water distribution
system is made of schedule 40 PVC pipe and EvapJet
ABS plastic water nozzles for critical corrosion protection.
The piping is easily removable for cleaning. The water
nozzles have a 1-inch diameter (25 mm) opening to help
eliminate costly clogging. In addition, the spray branches
have threaded end caps to allow easy debris removal.

Debris
Splashout

Superior Air Inlet Louver and Screen Design


(US Patent 7,927,196)
EVAPCOs water and sight tight (WST) inlet louver keeps
water in and sunlight out of your Advanced Technology
series cooling tower. The unique, non-planar design is
made from lightweight, framed PVC sections which have
no loose hardware, enabling easy unit access. The louvers
air channels are optimized to maintain fluid dynamic and
thermodynamic efficiency and block all line-of-sight paths
into the basin, eliminating splash-out even when the fans
are off. And because all sunlight is blocked, algae growth
is minimized. The end result: reduced maintenance hours,
water consumption, and water treatment costs.

The spray pressure for all Advanced Technology series


cooling towers is between 1 and 6 psig (7 and 41 kPa) at
the inlet header. (Actual spray pressure will be provided
on the submittal prepared for your unit.)

EvapJet nozzle compared


to previous EVAPCO nozzles

The POWER-BAND Belt Drive System

At the heart of every Advanced Technology series cooling tower is EVAPCOs POWER-BAND Belt Drive System. Tough
enough to handle the most heavy-duty cooling tower applications, its also the easiest drive system to maintain in the industry.

Fan Motors

POWER-BAND uses premium efficiency, inverter capable,


totally enclosed fan motors that are designed specifically
for cooling tower applications. A broad range of additional
motors, including multi-speed motors, space heaters, thermistors, and shaft grounding rings, are also available to meet
your specific needs.

Belt Drive

Specifically designed for cooling tower service, the


POWER-BAND drive is a solid-back multigroove belt
system with high lateral rigidity. The belt is constructed
of neoprene with polyester cords, and sized for 150%
of the motor nameplate horsepower to ensure long,
trouble-free operation.

Drive System Sheaves

POWER-BANDs drive system sheaves are constructed


of aluminum alloy for durability inside the cooling
towers warm, moist atmosphere. Models with totally
enclosed fan cooled (TEFC) motors have a steel driver
sheave protected by a hinged cover.

Fan Shaft Bearings

Rated for a minimum L10 life of 75,000 hours, POWERBANDs fan shaft bearings are the cooling tower industrys most heavy-duty pillow-block bearings. That means
longer operating life and less risk of costly downtime.

5-Year Motor and Drive Warranty

All POWER-BAND belt drives and optional gear drives come with EVAPCOs unique 5-year
motor and drive warranty. The comprehensive plan covers fans, fan shaft, belts, sheaves, fan
bearings, gear box, flexible coupling, driveshaft, and motors to give you total protection.

The Industrys Easiest Drive-System Maintenance

With POWER-BAND, all periodic maintenance can be safely performed from the side of your Advanced Technology series
cooling tower. No standing inside the cold water basinand no need for fan deck handrails or safety cages.

Standard Towers (8.5 Feet Wide or Less)

The totally enclosed fan cooled (TEFC) motor is mounted


on the outside and protected from the weather by a cover
that swings away for maintenance. A large, hinged access
door is located on the side of the unit for easy access to
the fan drive system. The belt can be adjusted by tightening the j-bolts on the motor base, and tension can be
checked easily through the access door. The bearing lubrication lines have been extended to the exterior casing
and are located by the access door, thus making bearing
lubrication easy. Sloped maintenance ladders and working
platforms are available to make maintenance even easier.
See page 10 for details.

Large Towers (Over 8.5 Feet Wide)

The totally enclosed air over (TEAO) motor is located


inside the fan casing and mounted on a unique, heavyduty adjustable motor base thats designed to swing
completely to the outside of the unit through a large,
hinged access door (14 square feet/1.3 square meters).
The belt can be easily adjusted from outside the unit via
an all-thread that runs through the motor base, or via
the motor bases unique locking mechanism if a wrench
is not available. Bearing lubrication fittings are extended
to the side of the unit inside the access door to allow for
easy application of the bearing lubricant. To facilitate
motor removal, an optional motor davit is available. See
page 10 for details.

Worry-Free Maintenance Basin Design

The cold water basin is the most important area of a cooling tower to maintain. Dirt and debris naturally collect there
as a result of the evaporation process and must be cleaned out on a regular basis. The basin section of every Advanced
Technology series cooling tower is designed to allow quick and easy accesspromoting routine maintenance of the
cold water basin.

Easy, Removable Air Inlet Louvers with


Quick Release Fasteners

Easy Access

The cold water basin section is easily accessible from


ground level by simply loosening the two quick release
fasteners on the inlet louver assemblies and lifting out the
lightweight louver. The basin can be accessed from all four
sides of the cooling tower, and the bottom of the fill section
is a minimum of 4 feet (1.2 m) above the basin floor. This
open design enables the basin to be easily cleaned. Note:
4-foot-wide models are accessible on only two sides.

Louver Access Door

To aid in basin maintenance, most Advanced Technology


models can be equipped with an optional louver access
door. This allows easy access to perform routine maintenance and inspection of the makeup assembly, strainer
screen, and basin without removing an entire inlet louver.
Note: This feature is standard on models with louvers 5 feet
and taller and optional on models with 4-foot-tall louvers.

Stainless Steel Strainers

For most cooling towers, the strainer is subject to excessive wear and corrosion. Not so with EVAPCOs cooling
towers. Our strainers are constructed with stainless steel
a long-standing EVAPCO standardensuring that yours
will last the life of your cooling tower.
9

The Advanced Technology series features a quick release


fastener design consisting of two large thumbscrews and
a retaining bracket system. By loosening the thumbscrews,
the retaining bracket lifts away from the louver frame, allowing the louver to be removed quickly and easily while
the retaining bracket and thumbscrews stay on the cooling
towerthus eliminating the possibility of missing hardware.

Clean Pan Design

The Advanced Technology series also features a completely sloped basin from the upper to lower pan section.
This clean pan design allows the water to be completely
drained from the basin. The cooling tower water will drain
from the upper section to the depressed lower pan section where the dirt and debris can be easily flushed out
through the drain. This design helps prevent buildup of
sedimentary deposits and biological films, and minimizes
standing water. Note: On 4-foot-wide units, the pan is
sloped without the step.

Optional Equipment

The standard design of the EVAPCO Advanced Technology series makes it the easiest cooling tower to maintain in the
industry. Take your tower to the next level with a host of options that can make maintenance even easier and extend the
life of your cooling tower even longer.

Sloped Maintenance Ladders

Designed by EVAPCO and OSHA-compliant, this sloped ships type


ladder enables visual inspection of the water distribution system and
drive components. Whats more, all standard drive system maintenance can be performed from the ladder. A handrail is attached to
the sloped ladder for safe and easy ascent and descentno need for
safety cages. Note: Available on all models wider than 4 feet. A vertical
ladder is available for smaller models. Ladder ships loose and must be
field mounted.

Working Platform & Ladder with Davit

Make it easy to service the fan motor and water distribution system with this
heavy-duty, self-supporting working platform and standard ladder. A less
expensive alternative to field erected catwalks, the system is OSHA compliant and ships in sections for easy installation. Note: The working platform is not
available on 4-foot-wide models.
Plus! Eliminate crane rentals with an optional davit that facilitates the easy
removal of motors, gear drives, and fans. The davit is constructed of aluminum
and is mounted on the side of the unit with a galvanized steel bracket. Note:
Davit ships loose and is installed in the field.

Stainless Steel Basin

The basin provides the structural support for the unit and is the most
important part of you cooling tower. Maximize its protection against
corrosion with EVAPCOs optional stainless steel water touch basin,
which uses type 304 or type 316 stainless steel for the entire basin area,
including the support columns and plenum of the cooling tower and
the louver frames.

Basin-Level Platform & Ladder

Available on select above-ground cooling tower models, the


basin-level platform and ladder facilitates easy basin inspections and maintenance, including float assembly adjustment and
basin/suction strainer cleaning. The platform and ladder ship in
modules for easy installation. Note: Ladder requires field support.

10

Optional Equipment: Electric Basin Heaters


Electric immersion heaters can be added to the basin of your Advanced Technology series cooling tower.
They are sized to maintain a +40 F (4.5 C) pan water temperature with the fans and system pumps off. A
thermostat and low-water protection device cycle the heater on when required and prevent the heater elements
from energizing unless they are completely submerged. All components are protected by rugged, weatherproof
enclosures for outdoor use.
AT/UT/USS Heater Sizes *
-20F
kW

-40F
kW

14-64 to14-94
14-66 to 14-96
14-69 to 14-99
14-612 to 14-912

2
3
4
5

3
4
5
7

4
5
7
9

19-56 to 19-96
19-28 to 19-98
19-59 to 19-99
19-111 to 19-911
19-412 to 19-912
19-114 to 19-914

5
6
7
8
(2) 4
(2) 5

7
8
10
12
(2) 7
(2) 7

9
12
15
15
(2) 9
(2) 10

110-112 to 110-912
110-118 to 110-918

(2) 5
(2) 7

(2) 8
(2) 12

(2) 10
(2) 15

112-012 to 112-912
112-314 to 112-914
112-018 to 112-918
112-520 to 112-920

(2) 6
(2) 7
(2) 9
(2) 10

(2) 9
(2) 10
(2) 15
(2) 15

(2) 12
(2) 15
(2) 18
(3) 15

114-0124 to114-1324
114-526 to 114-926

(2) 16
(2) 16

(3) 16
(3) 16

(3) 20
(3) 20

26-517 to 26-917

(2) 5

(2) 7

(2) 9

28-217 to 28-917

(2) 6

(2) 8

(2) 12

29-318 to 29-918
29-121 to 29-921
29-024 to 29-924
29-228 to 29-928

(2) 6
(2) 7
(4) 4
(4) 5

(2) 9
(2) 12
(4) 7
(4) 7

(2) 12
(2) 15
(4) 9
(4) 10

210-124 to 210-924
210-136 to 210-936

(4) 5
(4) 7

(4) 8
(4) 12

(4) 10
(4) 15

212-59 to 212-99
212-024 to 212-924
212-128 to 212-928
212-036 to 212-936
212-0140 to 212-1640

(2) 5
(4) 6
(4) 7
(4) 9
(4) 10

(2) 7
(4) 9
(4) 10
(4) 15
(4) 15

(2) 9
(4) 12
(4) 15
(4) 18
(4) 20

214-0148 to 214-1248
214-552 to 214-952

(4) 16
(4) 16

**
**

**
**

215-29 to 215-99

(2) 6

(2) 8

(2) 12

217-59 to 217-99
217-111 to 217-911
217-412 to 217-912
217-214 to 217-914

(2) 7
(2) 8
(4) 4
(4) 5

(2) 10
(2) 12
(4) 7
(4) 7

(2) 15
(2) 15
(4) 9
(4) 10

220-112 to 220-912
220-118 to 220-918

(4) 5
(4) 7

(4) 8
(4) 12

(4) 10
(4) 15

224-018 to 224-918
224-720 to 224-920

(4) 9
(4) 10

(4) 15
(4) 15

(4) 18
(4) 20

228-0124 to 228-1024
228-526 to 228-926

(4) 16
(4) 16

**
**

**
**

Note: Heater control packages that include contactor, transformer or disconnects are also available;
speak to your local EVAPCO representative to learn
more about these options.
AT/UT/USS Heater Sizes *

3-CELL

0F
kW

4-CELL

2-CELL

1-CELL

Model No.

Model No.

0F
kW

-20F
kW

-40F
kW

39-336 to 39-936
39-242 to 39-942

(6) 4
(6) 5

(6) 7
(6) 7

(6) 9
(6) 10

310-136 to 310-936
310-154 to 310-954

(6) 5
(6) 7

(6) 8
(6) 12

(6) 10
(6) 15

312-036 to 312-936
312-042 to 312-942
312-054 to 312-954
312-260 to 312-960

(6) 6
(6) 7
(6) 9
(6) 10

(6) 9
(6) 10
(6) 15
(6) 15

(6) 12
(6) 15
(6) 18
(9) 15

314-0172 to 314-1272
314-578 to 314-978
342-526 to 342-926

(6) 16
(6) 16
(6) 16

**
**
**

**
**
**

420-124 to 420-924
420-136 to 420-936

(4) 10
(4) 15

(4) 15
(4) 15

(4) 20
(4) 20

424-024 to 424-924
424-028 to 424-928
424-036 to 424-936
424-0140 to 424-1640

(4) 12
(4) 15
(4) 18
(4) 20

(4) 18
(4) 20
(6) 18
(6) 20

(6) 15
(6) 18
(8) 18
(8) 20

428-0148 to 428-1348
428-552 to 428-952
456-526 to 456-926

(8) 16
(8) 16
(8) 16

**
**
**

**
**
**

* Electric heater selection based on ambient air temperature shown.


11

** Consult factory

Optional Equipment
Electronic Water Level Control (EWLC)

Designed by and manufactured exclusively for EVAPCO, the electronic


water level control system provides precision control for the basin water
level and eliminates the need for field adjustment, even under varying operating conditions. The system uses heavy-duty stainless steel
electrodes, which are mounted outside the unit in a vertical stand pipe
that acts as a stilling chamber. (For winter operation, the stand pipe
must be wrapped with electric heating cable and insulated to protect
it from freezing.) Three-probe and five-probe packages are available.
The five-probe package provides high- and low-level alarms. The
weather-protected, slow-closing solenoid valve for the makeup water
connection is factory-supplied and ready for piping to a water supply
with a pressure between 5 and 125 psig (34 and 862 kPa).

Even More Options

Flanged Connections

Bypass Connections with


Diffuser Hood

Ask your EVAPCO representative about:


Vibration switches
Sump sweeper piping
FM approval
Bottom inlet and bottom suction connections
Remote sump connections (see page 85 for more information)
Materials for higher temperature applications
TITAN PAK stainless steel fill
WIDE-PAK for dirty water applications where TSS is less than
100 PPM
VERTICLEAN for dirty water applications where TSS is between
75 and 500 PPM

Equalizers and Flume Plates

12

Optional Equipment: Water Treatment Systems


EVAPCO has dramatically changed the water treatment game with the introduction of Pulse~Pure and Smart
Shield. Available as a complete water treatment system for coil products and open evaporative cooling applications.
Water treatment has never been easier or more dependable.

Pulse~Pure Non-Chemical Water Treatment System


Pulse~Pure from EVAPCO uses pulsed electric field technology to
treat your water without chemicals. Its the environmentally responsible
solution that also packs a powerful water-treating punch:
Emits short, high frequency bursts of low energy electromagnetic
fields to recirculating water
Forms seed crystals to attract and destroy scale-causing precipitants
and bacteria
Delivers a guaranteed maximum bacterial count of 10,000 CFU/
ml in the cooling waterwell below most chemical water treatment
solutions
Operates in an alkaline environment, allowing calcium carbonate to
act as a natural cathodic corrosion inhibitor, and yielding corrosion
rates equivalent to most chemical alternatives
Operates at higher cycles of concentration to save water
Compact design eliminates moving parts and ensures low energy
consumption

Learn more about Pulse~Pure


at evapco.com.

13

Optional Equipment: Water Treatment Systems


Warranty & Service Included
Each EVAPCO water treatment system is warranted by EVAPCO and comes standard with a one-year performance
monitoring and service program provided by a factory-trained EVAPCO representative.

Smart ShieldSolid Chemical Water


Treatment System
Proven solid chemistry. A revolutionary feed
system. Together, these make Smart Shield, the
easiest and safest chemical water treatment system
available today, featuring:
A solid chemistry design that eliminates liquid
chemical hazards including spills and the
need for expensive feed pumps
Reduced packaging, shipping and handling for
lower costs and a lower carbon footprint than
liquid chemicals
Smart Shield is available in two unique systems
to protect a broad range of evaporative cooling
water applications:
Controlled release system (shown at right) uses
scale and corrosion inhibitors utilizing polymer
coated no-touch chemical replenishments for
easier, safer reloads
Monitored release systems are applicable for
larger systems or those with higher inhibitor
demand. Monitored release scale and corrosion
inhibitors utilize uncoated tablets and a direct
detect probe for precise control of active
ingredients

EVAPCO Counductivity
Controller (ECC)

Bio-Control
Feeder (BCF)

CRF or MRF
Feeder

Watch a short product video at


smartshield.evapco.com.

Inhibitor Operation
1. Polymer coated inhibitor tablet
2. Recirculated water permeates the polymer coating
3. Solid chemistry becomes a slurry inside the tablet
4. Osmotic pressure causes the tablet to swell, forcing the chemistry out through the polymer coating
5. Polymer coating controls the treatment release rate
6. Treated water returns to the basin

14

Optional Equipment: Low Sound Solutions


Super Low Sound Fan 9-15 dB(A) Reduction
When youre tasked with achieving the lowest sound levels possible, theres only one choice: the EVAPCO super low sound fan,
the quietest, most noise efficient fan in the industrycapable of
reducing sound pressure level by 9 to 15 dB(A)! The super low
sound fan comes standard with all UT models in the Advanced
Technology series. See page 17 for more information. Note: Not
available on 4-foot-wide models.

Water Silencer Reduces Water Noise up to 7 dB(A)


Located in the cold water basin, EVAPCOs water silencer reduces the
high frequency noise associated with falling water and is capable of lowering overall sound levels 4 to 7 dB(A) when measured at 5 feet from the
side or end of the unit. When water is circulated with fans off, the results
are even greater: as much as 9 to 12 dB(A) lower at the same measured
distance (depending on water loading and louver height). Constructed of
lightweight PVC sections, the silencer can be easily removed for access
to the basin area. It will have no impact on thermal performance and is
CTI certified. Note: Not available on 4-foot-wide models.

Offset Sound Attenuation Walls


Add EVAPCOs CTI-certified offset sound attenuation walls to
your super low sound fan and water silencer options for the
ultimate sound control. Constructed of G-235 galvanized steel
and lined inside with acoustical padding, the walls will typically
reduce the 50-foot free-field sound level by an additional
3 dB(A). Stainless steel construction also available. Requires
external support by others. Note: Available only in combination
with super low sound fan and water silencer.

See page 21 for more information on EVAPCOs science of low sound.

15

Optional Equipment: Low Sound Solutions


Low Sound Fan 4-7 dB(A) Reduction
Ideal for sound-sensitive applications, EVAPCOs low sound fan features a wide chord blade and a unique
soft-connect blade-to-hub design that is compatible with variable speed drives. Since the blades are not
rigidly connected to the fan hub, no vertical vibration forces are transmitted to the unit structure. This reduces
sound pressure levels by 4 to 7 dB(A), depending on specific
unit selection and measurement location.
The fan is a high efficiency axial propeller and is CTI certified
on Advanced Technology series cooling towers. It has a thermal performance derate of up to 3.5%. Consult your EVAPCO
representative for actual thermal performance. Note: Available
on AT and USS models only.

14-64 to14-94
14-66 to 14-96
14-69 to 14-99
14-612 to 14-912

0
0
0
0

0
0
0
0

19-56 to 19-96
19-28 to 19-98
19-59 to 19-99
19-111 to 19-911
19-412 to 19-912
19-114 to 19-914

4
4
4
4
4
4

0
0
0
0
0
0

110-112 to 110-912
110-118 to 110-918

0
0

0
0

112-012 to 112-912
112-314 to 112-914
112-018 to 112-918
112-520 to 112-920

0
0
7
7

0
0
225
225

114-0124 to114-1324
114-526 to 114-926

5
7

450
450

26-517 to 26-917

28-217 to 28-917

29-318 to 29-918
29-121 to 29-921
29-024 to 29-924
29-228 to 29-928

4
4
4
4

0
0
0
0

210-124 to 210-924
210-136 to 210-936

0
0

0
0

212-59 to 212-99
212-024 to 212-924
212-128 to 212-928
212-036 to 212-936
212-0140 to 212-1640

4
0
0
7
7

0
0
0
450
450

214-0148 to 214-1248
214-552 to 214-952

5
7

900
900

2-CELL

Operating
Weight Addition
for Low Sound
Fan (lbs.)

3-CELL

Model No.

Height
Addition for
Low Sound Fan
(in.)

4-CELL

2-CELL

1-CELL

Additional Height & Operating Weight Additions


Model No.

Height
Addition for
Low Sound Fan
(in.)

Operating
Weight Addition
for Low Sound
Fan (lbs.)

215-29 to 215-99

217-59 to 217-99
217-111 to 217-911
217-412 to 217-912
217-214 to 217-914

4
4
4
4

0
0
0
0

220-112 to 220-912
220-118 to 220-918

0
0

0
0

224-018 to 224-918
224-720 to 224-920

7
7

450
450

228-0124 to 228-1024
228-526 to 228-926

5
7

900
900

39-336 to 39-936
39-242 to 39-942

4
4

0
0

310-136 to 310-936
310-154 to 310-954

0
0

0
0

312-036 to 312-936
312-042 to 312-942
312-054 to 312-954
312-260 to 312-960

0
0
7
7

0
0
675
675

314-0172 to 314-1272
314-578 to 314-978
342-526 to 342-926

5
7
7

1,350
1,350
1,350

420-124 to 420-924
420-136 to 420-936

0
0

0
0

424-024 to 424-924
424-028 to 424-928
424-036 to 424-936
424-0140 to 424-1640

0
0
7
7

0
0
900
900

428-0148 to 428-1348
428-552 to 428-952
456-526 to 456-926

5
7
7

1,800
1,800
1,800

16

UT: Ultra-QuieT Cooling Tower


Reduces Noise Pollution by More Than 50%

The Ultra-QuieT Cooling Tower delivers all the innovative


design and maintenance features of the original Advanced
Technology tower, with the added power of the industrys
quietest and most efficient fan: the EVAPCO super low
sound fan.
Reduced Sound Levels
Made of heavy-duty reinforced polyester, the fans ultra-wide
chord blades have a forward swept design and rounded
edges to minimize the sound caused by flow separation
and vortex shedding. The end result is a sound pressure
level thats 9 to 15 dB(A) lowermore than 50% lowerthan
standard fans (depending on specific unit selection and
measurement location). Best of all, the super low sound fan
has zero impact on thermal performance.
Improved Sound Quality
The super low sound fan eliminates audible blade passing
frequencies typical of straight-bladed axial type fans. The
narrow band spectrum graph below shows how straightbladed axial fans produce blade-passing frequenciesthe
same phenomena that produce a helicopters signature
pulsating noise. The blade-passing frequencies are audible
spikes in sound pressure levels, but are not apparent in the
octave band sound spectrum.

Sound Pressure Level (dB)

Note: UT towers are only available in sizes over 4 feet wide.


For additional height and operating weight additions, see the
dimensional data table for each model, starting on page 23.

Blade Passing
Frequencies

Standard Axial Fan


Super Low Sound Fan

More Options for Even Greater Sound Control


The Ultra-QuieT cooling tower can be used in
combination with EVAPCOs water silencers and offset
sound attenuation walls to produce the lowest sound levels
commercially available. See page 16 for details.
Consult EVAPCOs evapSelect selection software for unit
sound levels (see page 23). If a detailed analysis or full octave band datasheet is required for your application, please
consult your EVAPCO sales representative.
CTI Certified-Standard 201
Independently certified for guaranteed performance
No costly field performance tests required
*

Frequency (Hz)

Narrow Band Spectrum Analysis

17

USS: Ultra Stainless Steel


Complete Stainless Steel Construction for Maximum
Corrosion Resistance
What do you get when you combine the easy
maintenance and superior operation of the Advanced
Technology series with the industrys most durable
construction? The Ultra Stainless Steel (USS) from
EVAPCOthe finest factory assembled cooling tower
ever offered. Its all-stainless-steel construction makes
it 100% corrosion resistant from top to bottom.
The Industrys Highest Quality Cold Water Basin
Your cold water basin provides the structural support for
your cooling towerand yet its the area most susceptible
to corrosion. Thats why the Ultra Stainless Steel tower is
the only tower in the industry that comes standard with a
type 316 stainless steel cold water basinthe highest
quality basin available today. No other cooling tower in
the industry offers this level of protection as standard.

Premium Components
Type 316 Stainless Steel
Cold water basin
Vertical support columns
Air inlet louver frames
Plenum

Type 304 Stainless Steel*


Upper casing and structure
Mechanical equipment support
Fan cowl and fan guard

PVC
EVAPAK fill
Water distribution system
Patented air inlet louvers
Patented drift eliminators

*Complete 316 stainless steel construction available for a minimal cost upgrade

Exclusive 5-Year Complete Product Warranty


Covers the complete drive system, including the motor,
on belt or gear drive units
Covers the complete cooling tower from the cold water
basin to the fan discharge screen
Standard on all Ultra Stainless Steel models

*Mark owned by the Cooling Technology Institute

CTI Certified-Standard 201


Independently certified for guaranteed performance
No costly field performance tests required

18

Additional Resources:
Understanding & Specifying Sound
Sound
Sound is the alteration in pressure, stress, particle displacement and particle velocity, which is propagated in an elastic
material. Audible sound is the sensation produced at the ear
by very small pressure fluctuations in the air.
Sound Pressure
Sound pressure is the intensity of sound. Sound pressure (Lp)
in decibels is the ratio of measured pressure (P) in the air to a
reference sound pressure, PO=2 x 105 Pascal based on the
following formula:
L p (dB) = 10 log10 ( P2/ PO2)

Adding Multiple Sound Sources


Since the decibel is a logarithmic function, the numbers
are not added linearly. Therefore, two 73 dB sound sources
added together do not equal 146 dB. The resultant sound
would actually be 76 dB. The following table shows how to
add decibels from two sound sources.
Difference in dB Level

0 to 1
2 to 3


4 to 8
9 or greater

Sound pressure level is what is actually being measured


when sound data is recorded. Microphones that measure
sound are pressure-sensitive devices that are calibrated to
convert the sound pressure waves into decibels. Similar to
the intensity coming from a light bulb which gets dimmer as
one gets further and further away, sound pressure decreases
in decibels as your ear gets further from the sound source.

25
Ft. Candles

SOUND PRESSURE

25
Ft. Candles

100W

50
Ft. Candles 100
Ft. Candles

100 ft.

50 ft.

25 ft.

25 ft.

SOUND PRESSURE

19

50 ft.

100 ft.

SOUND POWER

7 dB(A)
73
dB((A))

Sound Pressure The A-Weighted Scale


The A-weighted scale, dB(A) is a means to translate what a
sound microphone measures to how the human ear perceives the sound. Use the following formula and conversions:

50

Ft. Candles 100


Sound power level is not a measured
value, but is
Ft. Candles
calculated based on the measured sound pressure.
Similar to the wattage of a light bulb that does not change
the farther one is away from the light bulb, sound power
100 ft. 50 ft. 25 ft.
25 ft.
does not vary with distance.
0

76 dB(
dB(A)
(A))

73 dB(A)
dB((A)
dB(A
dB(
A)

Sound Power
Sound power is the energy of sound. Sound power (Lw) in
decibels is the ratio of the calculated sound power, (W) to
a reference power, Wo=1 picowatt, according to the
following formula:
L W (dB) = 10 log10 (W/WO)

Add to the higher dB Level


3
2
1
0

f=8000
dB(A) =10 log 10
50 ft.

10 ((dB+Cf) /10)

f=63

100 ft.

where: C f = correction factor per band


dB = measured sound pressure

let: Z f = (dB + Cf)/10

Band

Center
Frequency (Hz)

Frequency
Range (Hz)

Sample
(Hz)

Cf
(dB)

Zf

63

44-88

68

-26.2

4.18

125

89-175

76

-16.1

5.99

250

176-350

77

-8.6

6.84

500

351-700

73

-3.2

6.98

1000

701-1400

70

7.00

2000

1401-2800

68

+1.2

6.92

4000

2801-5600

71

+1.0

7.20

8000

5601-11200

73

-1.1

7.19

Example calculation of the dB(A) formula using the sample data.


dB(A) = 10 log10 10(Z1) + 10(Z2) + 10(Z3) + 10(Z4) + 10(Z5) + 10(Z6) + 10(Z7) + 10(Z8)
= 10 log10 (67114245.2) = 78.3 dB(A)
100W

45

Fe
et
50
Existing
Cooling
Tower

Fe
et
50
et
Fe

Microphone Location

Microphone

50

A sound microphone should be located 5 feet above the


cooling tower fan cowl edge at a 45 angle. This position
assures accurate sound measurements and eliminates a
source of uncertainty by taking the microphone out of the
high velocity fan discharge air.

Rooftop
Air
Handler

et
Fe

Measurement Location
Per Cooling Technology Institute Standard ATC-128

New
Cooling
Tower

50

Specifying Sound
Specify sound pressure in dB(A) measured 5 feet above
the fan discharge during full speed operation.
All manufacturers can meet a performance specification
with low sound options
Fan noise is what matters. 5 feet above the fan is where
it matters.

Road
Traffic

Easy Verification
At 5 feet from the cooling tower, a sound meter records
only cooling tower noise. You can easily verify the actual
noise coming from the cooling tower against the specified
sound data with good certainty.
If sound were specified at 50 feet or some greater distance
from the sound-sensitive location, there is increased uncertainty in the measured data due to other possible sound
sources within the 50 foot radius of the sound microphone.
Sound Quality
Sound coming from the top of the cooling tower is comprised of low- and mid-frequency fan noise. Low- and
mid-frequency fan rumble is very difficult to attenuate. Fan
rumble travels through everything and around everything
and is what is audible at any sound-sensitive location.
Sound coming from the sides of the cooling tower is
comprised of high-frequency water noise, is much less
objectionable than fan noise, and attenuates naturally with
distance.

Typical Sound Pressure Levels of Well Known


Noises:
Jet Airplane, 150 feet away
140 dB(A)
Circular Saw
110 dB(A)
Nightclub
100 dB(A)
Semi Truck
90 dB(A)
Sidewalk of a Busy Road
80 dB(A)
Household Vacuum, 3 feet away
70 dB(A)
Normal Conversation
60 dB(A)
Quiet Library
40 dB(A)

Sound measured at the side of a cooling tower is inside the


acoustical shadow of the noise emitted from the top. Outside the acoustical shadow, the low- and mid-frequency fan
noise completely masks the high-frequency water noise.

Low-Mid Frequencies
Travel through and
around Obstructions
Fan Noise

Acoustical
Shadow

Notable Facts about Sound:


+/- 1 dB(A) is inaudible to the human ear
Decreasing a noise source by 10 dB(A) sounds half as loud
to the human ear

Water
Noise

High-Frequency
Self Attenuating
20

EVAPCO Technical Support Services

EVAPCO Representatives
Your EVAPCO representative is the local expert you can count on to help you with all your commercial HVAC needs
from getting quotes to answering questions to helping you manage your projects and orders. Simply contact him or her
whenever you need help; well get the job done. To find your local representative, visit evapco.com now.
evapSelect
evapSelect is a computer selection program that makes it easy for you to find and optimize the right EVAPCO solutions for every project. Evaluate thermal performance, space, and energy requirements across units; analyze optional
equipment features; and generate complete specifications and unit drawingsall within a friendly and familiar Windows
format. Contact your EVAPCO representative to access evapSelect now.
evapco.com
Bookmark evapco.com for the latest and most complete product information. The website contains a multitude of information and resources including:
Unit certified drawings (.pdf format)
Rigging instructions
Operation and maintenance instructions
Steel support drawings (.pdf format)
Scaled isometric views of towers in CAD (.dwg format)
Videos
Logo apparel and merchandise
3-D models of towers in Revit (.rfa format)
Product catalogs

21

Advanced Technology Series

AT | UT | USS

Engineering Data & Dimensions

Nomenclature

AT-215-89L

ACCESS DOORS SWING INSIDE U


(2) ACCESS DOOR

(2) ACCESS DOOR

(2) ACCESS DO

(3) 14 BFW/GVD EQUALIZER


(3) 14 BFW/GVD OUTLET

Product
Type

# of
Unit
Capacity
(3) 14 BFW/GVD INLET
Cells Width Indicator

Other
Unit
Length

Product Type
173-1/2 154-1/2
AT Indicates an Advanced Technology (AT)
tower 135-1/2
UT An AT tower with a super low sound fan
USS - An AT tower with stainless steel construction, 304, 316 or a combination. A USS tower may also
include a Super Low Sound Fan.
# of Cells
Determined by the number of inlet connections, can be 1, 2, 3, or 4

83-5/8
143
256

Unit Width
315-3/8
The total width of the unit in feet, all cells included. The value is rounded up to the next whole number.

428-3/8

487-3/4
Capacity Indicator
Relative performance indicator for example, an AT-215-89 has more capacity than an AT-215-49.
42' 8"
7

Unit Length
The total length of the unit in feet, all cells included. The value is rounded up to the next whole number.
Other
Some, but not all units endTwith a letter.
S Indicates a non-cataloged design.
L, U, M or E Indicates an alternateHmotor HP.

(2) ACCESS
DOOR

(2) ACCESS
DOOR

(2) ACCESS
DOOR

123-3/8
26
17-3/8
4
25' 8-7/8"

1- 3/8

157-1/4

(3) 3 MPT MAKE-UP

161-1/2

(3) 4 MPT OVERFLOW

162-1/2

(3) 4 MPT DRAIN

167-1/4

5-1/8
42' 8"

22

Models: AT/USS 14-64 to 14-96


One-Cell Cooling Towers

ACCESS DOOR

53-3/4"

ACCESS
DOOR

4 MPT INLET

24-1/8"

2 MPT OVERFLOW

P
1 MPT MAKE-UP

37-1/2"

4 MPT OUTLET

19-3/4"
13"
3"

5-1/8"

5-7/8"

2 MPT DRAIN

4-3/8"

1"

24-1/4"

38-1/4"
12-3/4"

4' 1/2"

Weights (LBS)

Model No.

Nominal
Tonnage

Shipping

Operating

AT-14-64
AT-14-74
AT-14-84
AT-14-94
AT-14-66
AT-14-76
AT-14-86
AT-14-96

33
37
39
43
57
64
67
74

1,080
1,160
1,130
1,210
1,390
1,490
1,410
1,510

1,760
1,840
1,810
1,890
2,460
2,560
2,480
2,580

NOTE:


(1)
(2)
(3)
(4)

730
810
780
860
950
1,050
970
1,070

Dimensions

Fan
Motor
(HP)

Air Flow
(CFM)

2
2
3
3
3
3
5
5

9,600
9,500
10,900
10,700
15,300
15,100
18,000
17,700

9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2

6 5
7 5
6 5
7 5
6 5
7 5
6 5
7 5

6 3
7 3
6 3
7 3
6 3
7 3
6 3
7 3

3 11-7/8
3 11-7/8
3 11-7/8
3 11-7/8
5 11-7/8
5 11-7/8
5 11-7/8
5 11-7/8

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

23

Heaviest
SectionF

F Heaviest section is upper section.

Models: AT/USS 14-69 to 14-912


One-Cell Cooling Towers

*14-69 to 14-99
(1) 4 Inlet
(1) 4 Outlet

ACCESS DOOR

ACCESS DOOR

53-3/4"

*14-612 to 14-912
(1) 6 Inlet
(1) 6 Outlet

ACCESS
DOOR

*MPT INLET

T
24-1/8"

ACCESS
DOOR

P
1 MPT MAKE-UP

2 MPT OVERFLOW

37-1/2"
*MPT OUTLET

13"
3"

5-1/8"
4-3/8"
38-1/4"
4' 1/2"

1"

Weights (LBS)

Model No.

Nominal
Tonnage

Shipping

Operating

AT-14-69
AT-14-79
AT-14-89
AT-14-99
AT-14-612
AT-14-712
AT-14-812
AT-14-912

76
86
90
100
115
129
137
150

2,000
2,160
2,100
2,260
2,530
2,730
2,570
2,770

3,600
3,760
3,700
3,860
4,700
4,900
4,740
4,940

NOTE:


(1)
(2)
(3)
(4)

5-7/8"
2 MPT DRAIN

24-1/4"
12-3/4"

19-3/4"

Heaviest
SectionF

1,380
1,540
1,480
1,640
1,770
1,970
1,810
2,010

Dimensions

Fan
Motor
(HP)

Air Flow
(CFM)

(2)2
(2)2
(2)3
(2)3
(2)3
(2)3
(2)5
(2)5

21,200
20,800
24,100
23,600
31,000
30,400
36,400
35,700

9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2

6 5
7 5
6 5
7 5
6 5
7 5
6 5
7 5

6 3
7 3
6 3
7 3
6 3
7 3
6 3
7 3

8 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
11 11-3/4
11 11-3/4
11 11-3/4
11 11-3/4

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

24

Models: AT/UT/USS 19-46 to 19-96


One-Cell Cooling Towers

SWING OUT RADIUS OF MOTOR COVER

30-5/8"

ACCESS DOOR

21-3/8"

M
T

ACCESS
DOOR

6 BFW/GROOVED
INLET

2"

50-3/4"

H
P
2 MPT
MAKE-UP

48-1/4"

6 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

23-1/8"
14-7/8"
6-1/2"

5-1/4"
9"

3-5/8"
5 11-7/8"

Model No.

AT-19-46
AT-19-56L
AT-19-56
AT-19-66
AT-19-76U
AT-19-76L
AT-19-76
AT-19-86
AT-19-96E
AT-19-96U
AT-19-96L
AT-19-96
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

109
89
112
123
101
124
138
150
130
143
157
171
21-3/8"

3 FPT
DRAIN

50-3/4"

3/8"

8' 5-1/2"

Weights (LBS)
Shipping

Operating

3,420
3,000
3,060
3,100
3,200
3,260
3,300
3,330
3,480
3,520
3,550
3,620
150

5,460
5,040
5,100
5,140
5,240
5,300
5,340
5,370
5,520
5,560
5,590
5,660
150

Fan Motor
(HP)

Heaviest
SectionF

2,370
1,950
2,010
2,050
2,150
2,210
2,250
2,280
2,430
2,470
2,500
2,570
150

Dimensions

Air Flow
(CFM)

3
3
5
7.5
3
5
7.5
10
5
7.5
10
15

21,900
22,600
26,500
30-5/8"
30,200
M
22,200
26,100
29,700
32,500
25,700
29,200
32,000
36,300

12 8-1/4
8 8
SWING OUT RADIUS OF MOTOR COVER
10 8-1/4
6 8
10 8-1/4
6 8
10 8-1/4
6 8
DOOR
11 ACCESS
8-1/4
7 8
11 8-1/4
7 8
11 8-1/4
7 8
11 8-1/4
7 8
12 8-1/4
8 8
12 8-1/4
8 8
12 8-1/4
8 8
12 8-1/4
8 8
1 1
1 1
ACCESS

9 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
8 2-1/2
8 2-1/2
8 2-1/2
8 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2

DOOR
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated
water.
T
6 BFW/GROOVED
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
INLET
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
50-3/4"
2"
Nominal Tonnage is based on 3 gpm per ton at 95
degree entering
water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
H

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


P

2 MPT
MAKE-UP

48-1/4"

6 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

23-1/8"
14-7/8"
6-1/2"

25

3-5/8"
7 5-7/8"

3/8"

5-1/4"

3 FPT
DRAIN

9"
50-3/4"
8' 5-1/2"

3-5/8"
5 11-7/8"

50-3/4"

3/8"

8' 5-1/2"

Models: AT/UT/USS 19-28 to 19-98


One-Cell Cooling Towers

SWING OUT RADIUS OF MOTOR COVER

30-5/8"

ACCESS DOOR

21-3/8"

M
T
2"

ACCESS
DOOR

6 BFW/GROOVED
INLET

50-3/4"

H
P
2 MPT
MAKE-UP

48-1/4"

6 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

23-1/8"
14-7/8"
6-1/2"
3-5/8"
7 5-7/8"

Model No.

AT-19-28L
AT-19-28
AT-19-38
AT-19-48
AT-19-58U
AT-19-58L
AT-19-58
AT-19-68
AT-19-78E
AT-19-78U
AT-19-78L
AT-19-78
AT-19-88
AT-19-98
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

109
137
148
159
123
152
165
179
133
159
173
187
197
207

Operating

3,390
3,450
3,490
3,520
3,620
3,680
3,720
3,750
3,890
3,950
3,990
4,020
3,810
4,080
150

5,810
5,870
5,910
5,940
6,040
6,100
6,140
6,170
6,310
6,370
6,410
6,440
6,230
6,500
150

3 FPT
DRAIN

9"
50-3/4"

3/8"

8' 5-1/2"

Weights (LBS)
Shipping

5-1/4"

Heaviest
SectionF

2,220
2,280
2,320
2,350
2,450
2,510
2,550
2,580
2,720
2,780
2,820
2,850
2,640
2,910
150

Fan Motor
(HP)

Air Flow
(CFM)

3
5
7.5
10
3
5
7.5
10
3
5
7.5
10
15
15

26,600
31,300
35,700
39,200
26,200
30,800
35,100
37,800
25,800
30,300
34,500
37,800
43,700
43,000

Dimensions
H

10 8-1/4
10 8-1/4
10 8-1/4
10 8-1/4
11 8-1/4
11 8-1/4
11 8-1/4
11 8-1/4
12 8-1/4
12 8-1/4
12 8-1/4
12 8-1/4
11 8-1/4
12 8-1/4
1 5

6 8
6 8
6 8
6 8
6 8
6 8
7 8
7 8
8 8
8 8
8 8
8 8
7 8
8 8
1 5

7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
8 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2
8 2-1/2
9 2-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

26

Models: AT/UT/USS 19-59 to 19-99


One-Cell Cooling Towers

SWING OUT RADIUS OF MOTOR COVER

30-5/8"
M

ACCESS DOOR

21-3/8"
M

T
2"

ACCESS
DOOR

8 BFW/GROOVED
INLET

4 5-3/4"

H
P
2 MPT
MAKE-UP

51-7/8"

8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

23-1/8"
14-7/8"

5-1/4"

3 FPT
DRAIN

7-1/2"
3-5/8"
8' 5-1/2"

Model No.

AT-19-59U
AT-19-59L
AT-19-59
AT-19-69E
AT-19-69U
AT-19-69L
AT-19-69
AT-19-79
AT-19-89E
AT-19-89U
AT-19-89L
AT-19-89
AT-19-99
UT Addition

Nominal
Tonnage

154
181
199
135
162
178
208
232
165
191
209
21-3/8"
242
265

3/8"

Shipping

Operating

4,250
4,290
4,320
3,980
4,020
4,050
4,120
4,390
4,560
4,600
4,630
4,700
4,750
150

7,090
7,130
7,160
6,820
6,860
6,890
6,960
7,230
7,400
7,440
7,470
7,540
7,590
150

(1)
(2)
(3)
(4)

4 5-3/4"
8 11-1/2"

Weights (LBS)
Heaviest
SectionF

2,940
2,980
3,010
2,670
2,710
2,740
2,810
3,080
3,250
3,290
3,320
3,390
3,440
T
150

2"

NOTE:


9"

Fan Motor
(HP)

Air Flow
(CFM)

5
7.5
10
5
7.5
10
15
15
5
7.5
10
15
20

35,300
40,100
43,900
35,900
40,800
44,700
50,800
49,800
34,700
39,500
43,200
49,000
53,600

Dimensions

SWING OUT RADIUS OF MOTOR COVER

30-5/8"

12 4-3/8
M
ACCESS DOOR
12 4-3/8
12 4-3/8
11 4-3/8
11 4-3/8
11 4-3/8
11 4-3/8
12 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
ACCESS
M
13 4-3/8 DOOR
8 BFW/GROOVED
1 9INLET

8 1/2
8 1/2
8 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
9 1/2
1 9

8 7-1/8
8 7-1/8
8 7-1/8
7 7-1/8
7 7-1/8
7 7-1/8
7 7-1/8
8 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8

5 2-3/4"

An adequately sized bleed line must be installed in the cooling tower system toP prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change. 2 MPT
MAKE-UP
51-7/8" tower. Refer to EVAPCOs Equipment Layout Manual.
Adequate spacing must be allowed for access to the cooling
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature,
and 78 degree wet-bulb temperature.
8 BFW/GROOVED

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

OUTLET

F Heaviest section is upper section.

3 FPT
OVERFLOW

23-1/8"

14-7/8"

5-1/4"

3 FPT
DRAIN

7-1/2"
3-5/8"
8' 5-1/2"

27

3/8"

9"

5 2-3/4"
10 5-1/2

2 MPT
MAKE-UP

51-7/8"

Models: AT/UT/USS 19-111 to 19-911

8 BFW/GROOVED
OUTLET

3 FPT
OVERFLOW

23-1/8"

14-7/8"
5-1/4"
One-Cell Cooling
Towers

3 FPT
DRAIN

7-1/2"

3-5/8"
8' 5-1/2"

9"

3/8"

4 5-3/4"
8 11-1/2"

SWING OUT RADIUS OF MOTOR COVER

30-5/8"
M

ACCESS DOOR

21-3/8"
M

ACCESS
DOOR

8 BFW/GROOVED
INLET

2"

5 2-3/4"

H
P
2 MPT
MAKE-UP

51-7/8"

8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

23-1/8"
14-7/8"

5-1/4"

3 FPT
DRAIN

7-1/2"
3-5/8"
8' 5-1/2"

Model No.

AT-19-111L
AT-19-111
AT-19-211
AT-19-311U
AT-19-311L
AT-19-311
AT-19-411
AT-19-511
AT-19-611E
AT-19-611U
AT-19-611L
AT-19-611
AT-19-711
AT-19-811
AT-19-911
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

156
187
202
172
202
221
231
256
190
220
238
270
285
298
314

9"

3/8"

10 5-1/2

Weights (LBS)
Shipping

Operating

4,530
4,570
4,600
4,850
4,890
4,920
4,670
4,990
5,200
5,240
5,270
5,340
5,040
5,390
5,420
150

7,830
7,870
7,900
8,150
8,190
8,220
7,970
8,290
8,500
8,540
8,570
8,640
8,340
8,690
8,720
150

5 2-3/4"

Heaviest
SectionF

3,060
3,100
3,130
3,380
3,420
3,450
3,200
3,520
3,730
3,770
3,800
3,870
3,570
3,920
3,950
150

Fan Motor
(HP)

Air Flow
(CFM)

5
7.5
10
5
7.5
10
15
15
5
7.5
10
15
20
20
25

40,200
45,800
50,200
39,700
45,100
49,400
57,100
56,100
39,000
44,300
48,600
55,100
61,300
60,300
64,600

Dimensions
H

11 4-3/8
11 4-3/8
11 4-3/8
12 4-3/8
12 4-3/8
12 4-3/8
11 4-3/8
12 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
12 4-3/8
13 4-3/8
13 4-3/8
1 9

7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9

7 7-1/8
7 7-1/8
7 7-1/8
8 7-1/8
8 7-1/8
8 7-1/8
7 7-1/8
8 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
8 7-1/8
9 7-1/8
9 7-1/8

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

28

Models: AT/UT/USS 19-412 to 19-912


One-Cell Cooling Towers

SWING OUT RADIUS OF MOTOR COVER

30-5/8"
M

ACCESS DOOR

21-3/8"

T
2"

ACCESS
DOOR

8 BFW/GROOVED
INLET

5 11-7/8"

H
P
2 MPT
MAKE-UP

56-1/4"

8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

23-1/8"
14-7/8"
7-1/2"
3-5/8"
8' 5-1/2"

Model No.

AT-19-412E
AT-19-412U
AT-19-412L
AT-19-412
AT-19-512U
AT-19-512L
AT-19-512
AT-19-612
AT-19-712E
AT-19-712U
AT-19-712L
21-3/8"
AT-19-712
AT-19-812
AT-19-912L
AT-19-912
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

203
230
257
283
229
256
289
319
243
268
299
330
340
M
352
363

5,080
5,110
5,190
5,230
5,440
5,470
5,550
5,590
5,830
5,860
5,940
5,980
5,610
6,000
6,020
150

9"

3 FPT
DRAIN

5 11-7/8"

3/8"

11 11-3/4"

Weights (LBS)
Shipping

5-1/4"

Operating

8,940
8,970
9,050
9,090
9,300
9,330
9,410
9,450
9,690
9,720
9,800
9,840
9,470
9,860
9,880
2"
150

Fan
Motor (HP)

Heaviest
SectionF

3,430
3,460
3,540
3,580
3,790
3,820
3,900
3,940
4,180
4,210
4,290
4,330
3,960
4,350
4,370
H 150

Air Flow (CFM)

7.5
10
15
20
7.5
10
15
20
7.5
10
15
20
25
25
30

50,600
55,400
63,100
69,100
49,800
54,500
61,900
67,800
49,000
53,600
61,000
66,700
72,800
71,500
75,800

Dimensions
H

6 11-7/8"

7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9

7 11-1/2
7 11-1/2
7 11-1/2
7 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2

SWING OUT RADIUS OF MOTOR COVER

30-5/8"11 8-3/4

11M 8-3/4
ACCESS DOOR
11 8-3/4
11 8-3/4
12 8-3/4
12 8-3/4
12 8-3/4
12 8-3/4
13 8-3/4
13 8-3/4
13 8-3/4
13 8-3/4
12
8-3/4
ACCESS
M
DOOR
13 88BFW/GROOVED
3/4
INLET
13 8 3/4
1 9

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
2 MPT
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
MAKE-UP
56-1/4"
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature,
and 78 degree wet-bulb temperature.
8 BFW/GROOVED
OUTLET

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section
23-1/8" is upper section.
14-7/8"
7-1/2"

29

3-5/8"
8' 5-1/2"

3/8"

5-1/4"
9"

3 FPT
OVERFLOW
3 FPT
DRAIN

6 11-7/8"
13 11-3/4"

14-7/8"
7-1/2"

5-1/4"

3 FPT
DRAIN

Models: AT/UT/USS 19-114 to 19-914


3-5/8"

3/8"

8' 5-1/2"

9"

5 11-7/8"

11 11-3/4"

One-Cell Cooling Towers

SWING OUT RADIUS OF MOTOR COVER

30-5/8"
M

ACCESS DOOR

21-3/8"

ACCESS
DOOR

8 BFW/GROOVED
INLET

2"

6 11-7/8"

H
P
2 MPT
MAKE-UP

56-1/4"

8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

23-1/8"
14-7/8"
7-1/2"
3-5/8"
8' 5-1/2"

Model No.

AT-19-114L
AT-19-114
AT-19-214L
AT-19-214
AT-19-314L
AT-19-314
AT-19-314M
AT-19-414
AT-19-514U
AT-19-514L
AT-19-514
AT-19-614
AT-19-714
AT-19-814
AT-19-914U
AT-19-914L
AT-19-914
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

221
251
249
280
280
309
337
315
266
295
329
347
377
399
361
391
413

5-1/4"
9"

3 FPT
DRAIN

6 11-7/8"

3/8"

13 11-3/4"

Weights (LBS)
Shipping

Operating

5,540
5,570
5,950
5,980
5,650
5,690
5,710
6,060
6,400
6,430
6,510
6,100
6,120
6,140
6,550
6,570
6,590
150

10,050
10,080
10,460
10,490
10,160
10,200
10,220
10,570
10,910
10,940
11,020
10,610
10,630
10,650
11,060
11,080
11,100
150

Heaviest
SectionF

3,680
3,710
4,090
4,120
3,790
3,830
3,850
4,200
4,540
4,570
4,650
4,240
4,260
4,280
4,690
4,710
4,730
150

Fan
Motor (HP)

Air Flow (CFM)

7.5
10
7.5
10
15
20
25
15
7.5
10
15
20
25
30
20
25
30

55,900
61,300
55,100
60,300
69,800
76,500
82,000
68,600
54,200
59,300
67,500
75,000
80,400
85,200
73,800
79,100
83,800

Dimensions
H

11 8-3/4
11 8-3/4
12 8-3/4
12 8-3/4
11 8 3/4
11 8 3/4
11 8 3/4
12 8-3/4
13 8-3/4
13 8-3/4
13 8-3/4
12 8-3/4
12 8-3/4
12 8-3/4
13 8 3/4
13 8 3/4
13 8 3/4
1 9

7 1/2
7 1/2
8 1/2
8 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
1 9

7 11-1/2
7 11-1/2
8 11-1/2
8 11-1/2
7 11-1/2
7 11-1/2
7 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

30

Models: AT/UT/USS 110-112 to 110-912


One-Cell Cooling Towers

ACCESS DOOR SWINGS


INSIDE UNIT
ACCESS DOOR

7"

ACCESS
DOOR

T
2"

8 BFW/GROOVED
INLET

71-7/8"

P
2 MPT
MAKE-UP

62-1/4"

8 BFW/GROOVED
OUTLET
25-1/4"
16-7/8"

5-1/4"

7-1/4"
9' 9-3/4"

Model No.

AT-110-112L
AT-110-112
AT-110-212E
AT-110-212U
AT-110-212L
AT-110-212
AT-110-312
AT-110-412
AT-110-512
AT-110-612E
AT-110-612U
AT-110-612L
AT-110-612
AT-110-712
AT-110-812
AT-110-912
UT Addition

NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

264
309
227
276
305
326
338
342
361
277
322
350
373
380
393
410

3/8"

Weights (LBS)
Shipping

Operating

6,840
6,840
6,290
6,360
6,410
6,460
6,890
6,560
6,940
7,190
7,260
7,310
7,360
7,040
7,460
7,710
700

12,380
12,380
11,830
11,900
11,950
12,000
12,430
12,100
12,480
12,730
12,800
12,850
12,900
12,580
13,000
13,250
700

Heaviest
SectionF

4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700

71-7/8"
11' 11-3/4"

Fan
Motor
(HP)

Air Flow
(CFM)

10
15
10
15
20
25
20
30
25
10
15
20
25
30
30
35

63,700
72,300
64,700
73,500
80,600
86,500
79,000
91,700
85,000
62,700
71,200
77,900
83,700
89,800
88,600
92,800

Dimensions
H

14 5-1/4
14 5-1/4
13 5-1/4
13 5-1/4
13 5-1/4
13 5-1/4
14 5-1/4
13 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
1 9-1/2

9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2

9 1
9 1
8 1
8 1
8 1
8 1
9 1
8 1
9 1
10 1
10 1
10 1
10 1
9 1
10 1
10 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

31

9"

3-5/8"

3 FPT
OVERFLOW
3 FPT
DRAIN

F Heaviest section is upper section.

Models: AT/UT/USS 110-118 to 110-918


One-Cell Cooling Towers

ACCESS DOOR SWINGS


INSIDE UNIT

ACCESS DOOR

7"

2"

ACCESS
DOOR

10 BFW/GROOVED
INLET

108

P
2 MPT
MAKE-UP

62-1/4"

10 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

25-1/4"
5-1/4"
16-7/8"

3 FPT
DRAIN

9"

8-1/2"
9' 9-3/4"

Model No.

AT-110-118U
AT-110-118L
AT-110-118
AT-110-218L
AT-110-218
AT-110-318U
AT-110-318L
AT-110-318
AT-110-418L
AT-110-418
AT-110-518
AT-110-618
AT-110-718U
AT-110-718L
AT-110-718
AT-110-818
AT-110-918
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

290
351
389
364
420
333
395
437
420
445
471
499
460
493
522
547
570

108"

3-5/8"

3/8"

Weights (LBS)
Shipping

Operating

8,790
8,860
8,910
10,180
10,180
9,480
9,550
9,600
8,960
9,060
9,650
9,750
10,230
10,280
10,380
10,000
10,630
700

17,200
17,320
17,320
18,590
18,590
17,890
17,960
18,010
17,370
17,470
18,060
18,160
18,640
18,690
18,790
18,410
19,040
700

Heaviest
SectionF

5,640
5,710
5,760
7,030
7,030
6,330
6,400
6,450
5,710
5,810
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700

18' 0"

Fan
Motor
(HP)

Air Flow
(CFM)

10
15
20
10
15
10
15
20
25
30
25
30
20
25
30
40
40

86,000
97,800
107,200
83,300
94,700
84,700
96,300
105,500
115,100
122,000
113,100
119,700
103,800
111,300
117,800
131,200
129,000

Dimensions
H

13 5-1/4
13 5-1/4
13 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
13 5-1/4
13 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
1 9-1/2

8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2

8 0
8 0
8 0
10 0
10 0
9 0
9 0
9 0
8 0
9 0
9 0
9 0
10 0
10 0
10 0
9 0
10 0

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

32

Models: AT/UT/USS 112-012 to 112-912


One-Cell Cooling Towers

ACCESS DOOR

ACCESS DOOR SWINGS


INSIDE UNIT

7"

ACCESS
DOOR

T
2"

8 BFW/GROOVED
INLET

71-7/8"

2 MPT
MAKE-UP

62-1/4"
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

25-1/4"
16-7/8"
7-1/4"
3-5/8"
5-1/4"

3 FPT
DRAIN

9"
11' 10"

Model No.

AT-112-012L
AT-112-012
AT-112-112
AT-112-212
AT-112-312U
AT-112-312L
AT-112-312
AT-112-412
AT-112-512U
AT-112-512L
AT-112-512
AT-112-612
AT-112-712
AT-112-812L
AT-112-812
AT-112-912
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

280
334
364
391
316
370
404
414
337
387
422
434
461
454
481
515

11' 11-3/4"

Weights (LBS)
Shipping

Operating

7,370
7,440
7,490
7,540
7,910
7,980
8,030
7,640
8,400
8,470
8,520
8,080
8,180
8,570
8,670
8,920
700

13,580
13,650
13,700
13,750
14,120
14,190
14,240
13,850
14,610
14,680
14,730
14,290
14,390
14,780
14,880
15,130
700

Heaviest
SectionF

4,930
5,000
5,050
5,100
5,470
5,540
5,590
5,200
5,960
6,030
6,080
5,640
5,740
6,130
6,230
6,480
700

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

10
15
20
25
10
15
20
30
10
15
20
25
30
25
30
40

71,600
81,400
89,300
95,800
70,500
80,000
87,700
101,500
69,300
78,700
86,300
94,000
99,500
92,400
97,900
107,100

13 6-1/4
13 6-1/4
13 6-1/4
13 6-1/4
14 6-1/4
14 6-1/4
14 6-1/4
13 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
14 6-1/4
14 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
1 9-1/2

8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 9-1/2

8 2
8 2
8 2
8 2
9 2
9 2
9 2
8 2
10 2
10 2
10 2
9 2
9 2
10 2
10 2
10 2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

33

71-7/8"

3/8"

F Heaviest section is upper section.

Models: AT/UT/USS 112-314 to 112-914


One-Cell Cooling Towers
ACCESS DOOR

ACCESS DOOR SWINGS


INSIDE UNIT

7"

ACCESS
DOOR

T
2"

10 BFW/GROOVED
INLET

83-7/8"

2 MPT
MAKE-UP

68-1/4"
10 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW

25-1/4"
16-7/8"
8-1/2"
3-5/8"
5-1/4"

3 FPT
DRAIN

9"
11' 10"

Model No.

AT-112-214
AT-112-314L
AT-112-314E
AT-112-314U
AT-112-314
AT-112-414E
AT-112-414U
AT-112-414L
AT-112-414
AT-112-514E
AT-112-514U
AT-112-514L
AT-112-514
AT-112-614
AT-112-714
AT-112-814
AT-112-914
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

299
425
359
394
450
344
405
439
471
370
427
460
494
501
524
548
574

83-7/8"

3/8"

13' 11-3/4"

Weights (LBS)
Shipping

Operating

8,010
8,200
8,080
8,140
8,270
8,670
8,740
8,800
8,860
9,190
9,260
9,320
9,380
8,930
9,450
9,190
9,710
700

15,340
15,530
15,410
15,470
15,600
16,000
16,070
16,130
16,190
16,520
16,590
16,650
16,710
16,260
16,780
16,520
17,040
700

Heaviest
SectionF

5,360
5,550
5,430
5,490
5,620
6,020
6,090
6,150
6,210
6,540
6,610
6,670
6,730
6,280
6,800
6,540
7,060
700

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

10
25
15
20
30
10
15
20
25
10
15
20
25
30
30
40
40

77,800
104,100
88,500
97,000
110,400
76,600
87,000
95,400
102,300
75,300
85,600
93,800
100,600
108,300
106,600
118,600
116,600

14 1/4
14 1/4
14 1/4
14 1/4
14 1/4
15 1/4
15 1/4
15 1/4
15 1/4
16 1/4
16 1/4
16 1/4
16 1/4
15 1/4
16 1/4
15 1/4
16 1/4
1 9-1/2

8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
1 9-1/2

8 7
8 7
8 7
8 7
8 7
9 7
9 7
9 7
9 7
10 7
10 7
10 7
10 7
9 7
10 7
9 7
10 7

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

34

Models: AT/UT/USS 112-018 to 112-918


One-Cell Cooling Towers

ACCESS DOOR

ACCESS DOOR
SWINGS INSIDE UNIT

7"

ACCESS
DOOR

10 BFW/GROOVED
INLET

2"

P
2 MPT
MAKE-UP

74-1/4"

10 BFW/GROOVED
OUTLET
3 FPT OVERFLOW

25-1/4"
16-7/8"

5-1/4"

8-1/2"

9"

3-5/8"
11' 10"

Nominal
Tonnage

Model No.

AT-112-018U
AT-112-018L
AT-112-018
AT-112-118
AT-112-118M
AT-112-218U
AT-112-218L
AT-112-218
AT-112-318
AT-112-418E
AT-112-418U
AT-112-418L
AT-112-418
AT-112-518
AT-112-618
AT-112-718
AT-112-818
AT-112-918
UT Addition
NOTE:


(1)
(2)
(3)
(4)

439
497
525
554
610
488
546
581
614
518
572
606
642
675
705
724
757
785

3/8"

18

Weights (LBS)
Shipping

Operating

10,260
10,320
10,370
10,480
10,740
11,040
11,100
11,150
11,260
11,780
11,840
11,890
12,000
11,520
12,260
11,580
12,320
12,430
1,200

19,530
19,590
19,640
19,750
20,010
20,310
20,370
20,420
20,530
21,050
21,110
21,160
21,270
20,790
21,530
20,850
21,590
21,700
1,200

Heaviest
SectionF

7"

T
2"

Fan Motor
(HP)

Air Flow
(CFM)

15
20
25
30
40
15
20
25
30
15
20
25
30
40
40
50
50
60

110,100
120,600
129,600
137,400
150,500
108,500
118,700
127,400
135,000
106,700
116,800
125,400
132,900
147,700
145,300
158,500
155,600
165,000

6,700
6,760
6,810
6,920
7,180
7,480
7,540
7,590
7,700
8,220
8,280
8,330
8,440
7,960
8,700
8,020
8,760
8,870
1,200
H

10

Dimensions
H

14 6 1/4
8 4
14 6 1/4
8 4
ACCESS DOOR
14 ACCESS
6 1/4
4 UNIT
SWINGS8
INSIDE
DOOR
14 6 1/4
8 4
14 6 1/4
8 4
15 6 1/4
9 4
15 6 1/4
9 4
15 6 1/4
9 4
15 6 1/4
9 4
16 6 1/4
10 4
16 6 1/4
10 4
16 6 1/4
10 4
16 6 1/4
10 4
15 6 1/4
9 4
16 6 1/4
10 4
15 6 1/4
9 4
ACCESS
DOOR
16 6 1/4
10 4
16
1/4
10 4
10 6
BFW/GROOVED
1INLET
3-1/2
1 3-1/2

9 1
9 1
9 1
9 1
9 1
10 1
10 1
10 1
10 1
11 1
11 1
11 1
11 1
10 1
11 1
10 1
11 1
11 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights
are subject to change.
P
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
2 MPT
74-1/4"
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature,
MAKE-UP85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

3 FPT OVERFLOW

25-1/4"

8-1/2"
3-5/8"
11' 10"

10 BFW/GROOVED
OUTLET

F Heaviest section is upper section.


16-7/8"

35

3 FPT DRAIN

3/8"

5-1/4"
9"

3 FPT DRAIN

10
20

3-5/8"

3/8"

11' 10"

18

Models: AT/UT/USS 112-320 to 112-920


One-Cell Cooling Towers

ACCESS DOOR

ACCESS DOOR
SWINGS INSIDE UNIT

7"

ACCESS
DOOR

T
2"

10 BFW/GROOVED
INLET

10
H

P
2 MPT
MAKE-UP

74-1/4"

10 BFW/GROOVED
OUTLET
3 FPT OVERFLOW

25-1/4"
16-7/8"
8-1/2"
3-5/8"
11' 10"

Nominal
Tonnage

Model No.

AT-112-320
AT-112-420
AT-112-520E
AT-112-520U
AT-112-520L
AT-112-520
AT-112-620E
AT-112-620U
AT-112-620L
AT-112-620
AT-112-720E
AT-112-720U
AT-112-720L
AT-112-720
AT-112-820
AT-112-920
UT Addition
NOTE:


(1)
(2)
(3)
(4)

459
536
506
544
625
679
572
618
655
728
585
623
698
757
788
817

5-1/4"

3 FPT DRAIN

9"

10

3/8"

20

Weights (LBS)
Shipping

Operating

11,020
11,750
11,070
11,180
11,440
11,500
12,650
12,700
12,810
13,070
11,800
11,910
12,170
12,230
13,130
13,240
1,200

21,420
22,150
21,470
21,580
21,840
21,900
23,050
23,100
23,210
23,470
22,200
22,310
22,570
22,630
23,530
23,640
1,200

Heaviest
SectionF

7,210
7,940
7,260
7,370
7,630
7,690
8,840
8,890
9,000
9,260
7,990
8,100
8,360
8,420
9,320
9,430
1,200

Fan Motor
(HP)

Air Flow
(CFM)

20
20
25
30
40
50
20
25
30
40
25
30
40
50
50
60

123,900
121,800
133,000
140,900
154,100
165,300
119,800
128,500
136,100
148,800
130,700
138,300
151,200
162,200
159,500
169,100

Dimensions
H

14 6 1/4
15 6 1/4
14 6 1/4
14 6 1/4
14 6 1/4
14 6 1/4
16 6 1/4
16 6 1/4
16 6 1/4
16 6 1/4
15 6 1/4
15 6 1/4
15 6 1/4
15 6 1/4
16 6 1/4
16 6 1/4
1 3-1/2

8 4
9 4
8 4
8 4
8 4
8 4
10 4
10 4
10 4
10 4
9 4
9 4
9 4
9 4
10 4
10 4
1 3-1/2

9 1
10 1
9 1
9 1
9 1
9 1
11 1
11 1
11 1
11 1
10 1
10 1
10 1
10 1
11 1
11 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

36

Models: AT/UT/USS 114-0124 to 114-1324


One-Cell Cooling Towers

ACCESS DOOR SWINGS INSIDE UNIT


ACCESS DOOR

7"

ACCESS
DOOR
T
14 BFW/GOOVED
INLET

142-1/2"

2"
H

P
99-3/8"

4 FPT
OVERFLOW
14 BFW/GROOVED
OUTLET

26"

17-3/8"
9"
13' 11 1/4"

Model No.

AT-114-0124U
AT-114-0124L
AT-114-0124
AT-114-0224
AT-114-0324L
AT-114-0324
AT-114-0424
AT-114-0524
AT-114-0624E
AT-114-0624U
AT-114-0624L
AT-114-0624
AT-114-0724
AT-114-0824
AT-114-0924
AT-114-1024
AT-114-1124
AT-114-1224
AT-114-1324*
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

619
684
722
781
772
834
839
872
708
775
812
892
947
951
998
1,008
1,056
1,135
1,201

4-1/8"

3/8"

Weights (LBS)
Shipping

Operating

16,440
16,490
16,510
16,660
18,520
18,570
17,010
18,590
17,480
17,530
17,550
17,700
18,740
18,050
19,090
18,220
19,260
19,500
19,940
1,250

32,290
32,340
32,360
32,510
34,370
34,420
32,860
34,440
33,330
33,380
33,400
33,550
34,590
33,900
34,940
34,070
35,110
35,350
35,790
1,250

4 FPT
DRAIN

9"

Heaviest
SectionF

10,600
10,650
10,670
10,820
12,680
12,730
11,170
12,750
11,640
11,690
11,710
11,860
12,900
12,210
13,250
12,380
13,420
13,660
14,100
1,250

3 MPT
MAKE-UP

72-1/4"
142-1/2"
23'-9"

Fan
Motor
(HP)

Air Flow
(CFM)

20
25
30
40
20
25
50
30
20
25
30
40
40
50
50
60
60
75
100

159,500
170,100
180,300
197,600
152,100
163,200
212,300
173,400
157,100
168,500
177,400
194,100
190,900
208,500
205,000
220,600
217,100
238,000
255,100

Dimensions
H

17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
17 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2

9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
9 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2

11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
11 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
12 3-7/8
13 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

* Model available with gear drive only. Motor and access door located on 13 11-1/4 unit end. Super Low Sound Fan is not available on this unit.

37

Models: AT/UT/USS 114-526 to 114-926


One-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

14 BFW/GROOVED
INLET

T
2"

154-1/2"

123-3/8"

4 FPT
OVERFLOW

14 BFW/GROOVED
OUTLET

26"

17-3/8"
9"

9"

4-1/8"

3 MPT
MAKE-UP

4 FPT
DRAIN
78-1/4"
154-1/2"

13' 11-1/4"

Model No.

AT-114-526
AT-114-626
AT-114-726
AT-114-826
AT-114-926
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,003
1,078
1,142
1,247
1,332

3/8"

25' 8-7/8"

Weights (LBS)
Shipping

Operating

24,800
24,860
24,960
25,280
25,300
D

41,630
41,690
41,790
42,110
42,130
2,400

Heaviest
SectionF

17,660
17,720
17,820
18,140
18,160
D

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

(2)20
(2)25
(2)30
(2)40
(2)50

200,200
214,700
227,300
248,500
266,300

22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2

12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2

16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

38

Models: AT/UT/USS 26-417 to 26-917


Two-Cell Cooling Towers

SWING OUT RADIUS


OF MOTOR COVER
30-5/8

30-5/8
ACCESS DOOR

ACCESS DOOR

21-3/8

ACCESS
DOOR

T
2

(2) 6 BFW/GROOVED
INLET

ACCESS
DOOR

50-3/4

P
4 3-7/8
(2) 6 BFW/GROOVED
OUTLET

23-1/8
14-7/8

(2) 3 FPT OVERFLOW


(2) 3 FPT DRAIN
50-3/4

5-1/4

3-5/8
5 11-7/8

Model No.

AT-26-417
AT-26-517L
AT-26-517
AT-26-617
AT-26-717U
AT-26-717L
AT-26-717
AT-26-817
AT-26-917E
AT-26-917U
AT-26-917L
AT-26-917
21-3/8"
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

219
179
225
247
203
250
277
302
262
287
315
344

(2) 2 MPT MAKE-UP


92-1/2

6-1/2

101-3/8

2-1/2
17' 1-1/2"

3/8

Weights (LBS)
Shipping

Operating

6,920
6,080
6,120
6,200
6,480
6,520
6,600
6,660
6,960
7,040
7,100
7,240
300

11,000
10,160
10,200
10,280
10,560
10,600
10,680
10,740
11,040
11,120
11,180
11,320
300

Fan Motor
(HP)

Heaviest
SectionF

2,410
1,990
2,010
2,050
2,190
2,210
2,250
2,280
2,430
2,470
2,500
2,570
150

(2)3
(2)3
(2)5
(2)7.5
(2) 3
(2)5
(2)7.5
(2)10
(2)5
(2)7.5
(2)10
(2)15

Dimensions

Air Flow
(CFM)

SWING
OUT RADIUS12
43,800
OF MOTOR COVER

30-5/8"

11-7/8
45,200
10 11-7/8
30-5/8"
53,100
10 11-7/8
60,500
ACCESS DOOR10 11-7/8
44,500
11 11-7/8
52,300
11 11-7/8
59,400
11 11-7/8
65,100
11 11-7/8
51,400
12 11-7/8
58,500
12 11-7/8
64,000
12 11-7/8
72,800
12 11-7/8
1 1

8 8
6 8
6 8
6 8 DOOR
ACCESS
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
1 1
ACCESS

ACCESS

DOOR
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up ofDOOR
impurities in (2)
the6recirculated
water.
BFW/GROOVED
T
Do not use catalog drawings for certified prints.
Dimensions and weights are subject to change.
INLET
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
50-3/4"
2" ton at 95 degree entering water temperature,
Nominal Tonnage is based on 3 gpm per
85 degree leaving water temperature, and 78 degree wet-bulb temperature.
H

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


P

4 8-1/4"
(2) 6 BFW/GROOVED
OUTLET

39

9 6
7 6
7 6
7 6
8 6
8 6
8 6
8 6
9 6
9 6
9 6
9 6

23-1/8"
14-7/8"
6-1/2"
3-5/8"

(2) 3 FPT OVERFLOW


(2) 3 FPT DRAIN
50-3/4"

(2) 2 MPT MAKE-UP


92-1/2"
5-1/4"
101-3/8"

2-1/2"

23-1/8
14-7/8

(2) 3 FPT DRAIN


50-3/4

(2) 2 MPT MAKE-UP

Models: AT/UT/USS 28-217 to 28-917


92-1/2

6-1/2

5-1/4

3-5/8

5 11-7/8

101-3/8

2-1/2

Two-Cell Cooling Towers

3/8

17' 1-1/2"

SWING OUT RADIUS


OF MOTOR COVER
30-5/8"

30-5/8"
ACCESS DOOR

ACCESS DOOR

21-3/8"

ACCESS
DOOR

T
2"

(2) 6 BFW/GROOVED
INLET

ACCESS
DOOR

50-3/4"

P
4 8-1/4"
(2) 6 BFW/GROOVED
OUTLET

23-1/8"
14-7/8"

(2) 3 FPT OVERFLOW


(2) 3 FPT DRAIN
50-3/4"

5-1/4"

3-5/8"
7 5-7/8"

Model No.

AT-28-217L
AT-28-217
AT-28-317
AT-28-417
AT-28-517U
AT-28-517L
AT-28-517
AT-28-617
AT-28-717E
AT-28-717U
AT-28-717L
AT-28-717
AT-28-817
AT-28-917
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

217
274
297
319
247
304
331
358
267
319
346
373
393
414

(2) 2 MPT MAKE-UP


92-1/2"

6-1/2"

101-3/8"

Weights (LBS)
Shipping

Operating

6,860
6,900
6,980
7,040
7,320
7,360
7,440
7,500
7,860
7,900
7,980
8,040
7,620
8,160
300

11,700
11,740
11,820
11,880
12,160
12,200
12,280
12,340
12,700
12,740
12,820
12,880
12,460
13,000
300

2-1/2"
17' 1-1/2"

3/8"

Heaviest
SectionF

2,260
2,280
2,320
2,350
2,490
2,510
2,550
2,580
2,760
2,780
2,820
2,850
2,640
2,910
150

Fan Motor
(HP)

Air Flow
(CFM)

(2)3
(2)5
(2)7.5
(2)10
(2)3
(2)5
(2)7.5
(2)10
(2) 3
(2)5
(2)7.5
(2)10
(2)15
(2)15

53,200
62,600
71,400
78,300
52,500
61,600
70,200
76,900
51,600
60,600
69,100
75,700
87,500
86,000

Dimensions
H

11 4-1/4
11 4-1/4
11 4-1/4
11 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
12 4-1/4
13 4-1/4
1 5

6 8
6 8
6 8
6 8
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
7 8
8 8
1 5

7 10-1/2
7 10-1/2
7 10-1/2
7 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
8 10-1/2
9 10-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

40

Models: AT/UT/USS 29-318 to 29-918


Two-Cell Cooling Towers

SWING OUT RADIUS


OF MOTOR COVER
30-5/8"

30-5/8"

ACCESS DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

21-3/8"

M
T

(2) 8 BFW/GROOVED INLET

4 5-3/4"
2"

4 5-3/4"

P
2 MPT
MAKE-UP

60-1/4"

(2) 8 BFW/GROOVED OUTLET


3 FPT
OVERFLOW
3 FPT DRAIN

23-1/8"
14-7/8"
7-1/2"
8' 5 -1/2"

Nominal
Tonnage

Model No.

AT-29-318L
AT-29-318
AT-29-418
AT-29-518U
AT-29-518L
AT-29-518
AT-29-618
AT-29-718
AT-29-818E
AT-29-818U
AT-29-818L
AT-29-818
AT-29-918
UT Addition
NOTE:


(1)
(2)
(3)
(4)

274
329
362
312
368
404
422
471
335
387
425
491
538

9"
5-1/4"

4 5-3/4"

3-5/8"

3/8"

Weights (LBS)
Shipping

Operating

7,840
7,920
7,980
8,370
8,450
8,510
8,120
8,650
8,950
9,030
9,090
9,230
9,330
300

13,730
13,810
13,870
14,260
14,340
14,400
14,010
14,540
14,840
14,920
14,980
15,120
15,220
300

Fan
Motor (HP)

Heaviest
SectionF

5,290
5,370
5,430
5,820
5,900
5,960
5,570
6,100
6,400
6,480
6,540
6,680
6,780
300

4 5-3/4"
18

(2)5
(2)7.5
(2) 10
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)20

Dimensions

Air Flow (CFM)

72,000
12 3/4
81,900
12 3/4
89,800
12 3/4
70,900
13 3/4
SWING OUT RADIUS
OF MOTOR COVER
80,600
13 3/4
30-5/8"
30-5/8"
88,200
13 3/4
M
ACCESS DOOR
102,000
12 3/4
100,100
13 3/4
69,700
14 3/4
79,300
14 3/4
86,800
14 3/4
98,400
14 3/4
107,600
14 3/4
1 9

7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
ACCESS DOOR
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
9 1/2
1 9

8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
8 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2

21-3/8"

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
ACCESS
ACCESS
M spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment
M Layout
M
Adequate
DOOR Manual.
DOOR
T degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
Nominal Tonnage is based on 3 gpm per ton at 95
(2) 8 BFW/GROOVED INLET

Outlet connection extends beyond bottom flange.


2"
Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


5 3-3/4"

5 3-3/4"

P
2 MPT
MAKE-UP

60-1/4"

(2) 8 BFW/GROOVED OUTLET


3 FPT
OVERFLOW
3 FPT DRAIN

23-1/8"
14-7/8"

41

7-1/2"
8' 5 -1/2"

3/8"

3-5/8"

9"
5-1/4"

5 3-3/4"

5 3-3/4"
21

5-1/4"

7-1/2"
8' 5 -1/2"

3-5/8"

3/8"

4 5-3/4"

4 5-3/4"
18

Models: AT/UT/USS 29-318 to 29-921


Two-Cell Cooling Towers

SWING OUT RADIUS


OF MOTOR COVER
30-5/8"

30-5/8"

ACCESS DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

21-3/8"

M
T

(2) 8 BFW/GROOVED INLET

5 3-3/4"
2"

5 3-3/4"

P
2 MPT
MAKE-UP

60-1/4"

(2) 8 BFW/GROOVED OUTLET


3 FPT
OVERFLOW
3 FPT DRAIN

23-1/8"
9"
5-1/4"

14-7/8"
7-1/2"
8' 5 -1/2"

Nominal
Tonnage

Model No.

AT-29-121L
AT-29-121
AT-29-221L
AT-29-221
AT-29-321
AT-29-421L
AT-29-421
AT-29-521U
AT-29-521L
AT-29-521
AT-29-621
AT-29-721
AT-29-821
AT-29-921L
AT-29-921
UT Addition

NOTE:


(1)
(2)
(3)
(4)

315
379
347
410
448
408
467
383
445
482
518
547
578
604
636

3-5/8"

3/8"

Weights (LBS)
Shipping

Operating

8,920
9,000
9,530
9,610
9,670
9,060
9,200
10,190
10,270
10,330
9,810
10,470
9,910
10,570
10,630
300

15,860
15,940
16,470
16,550
16,610
16,000
16,140
17,130
17,210
17,270
16,750
17,410
16,850
17,510
17,570
300

Heaviest
SectionF

6,130
6,210
6,740
6,820
6,880
6,270
6,410
7,400
7,480
7,540
7,020
7,680
7,120
7,780
7,840
300

5 3-3/4"

5 3-3/4"
21

Fan
Motor (HP)

Air Flow (CFM)

(2)5
(2)7.5
(2)5
(2)7.5
(2)10
(2)10
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)20
(2)20
(2)25

80,700
91,800
79,600
90,500
99,200
100,700
114,600
78,200
88,900
97,500
112,500
110,700
123,000
120,900
129,800

Dimensions
H

12 3/4
12 3/4
13 3/4
13 3/4
13 3/4
12 3/4
12 3/4
14 3/4
14 3/4
14 3/4
13 3/4
14 3/4
13 3/4
14 3/4
14 3/4
1 9

7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
7 1/2
7 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9

8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
8 3-1/2
8 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

42

Models: AT/UT/USS 29-024 to 29-924


Two-Cell Cooling Towers

SWING OUT RADIUS


OF MOTOR COVER
30-5/8

30-5/8
ACCESS DOOR

ACCESS DOOR

21-3/8"
ACCESS
DOOR

ACCESS
DOOR
T

(2) 8 BFW/GROOVED
INLET
71-7/8"

2"

H
P
60-1/4"
(2) 8 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW
(2) 3 FPT DRAIN

23-1/8"

71-7/8"

14-7/8"

(2) 2 MPT MAKE-UP

134-3/4"

7-1/2"

5-1/4"

3-5/8"
143-3/4"
8' 5-1/2"

Model No.

AT-29-024L
AT-29-024
AT-29-124L
AT-29-124
AT-29-224E
AT-29-224U
AT-29-224L
AT-29-224
AT-29-324
AT-29-424
AT-29-524
AT-29-624
AT-29-724
AT-29-824
AT-29-924
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

452
506
481
531
400
454
507
559
571
593
630
653
674
696
718

24' 2"

Weights (LBS)
Shipping

Operating

10,860
10,920
11,640
11,700
10,140
10,200
10,360
10,440
11,080
11,860
11,160
11,940
11,200
11,980
12,020
300

18,580
18,640
19,360
19,420
17,860
17,920
18,080
18,160
18,800
19,580
18,880
19,660
18,920
19,700
19,740
300

Heaviest
SectionF

3,790
3,820
4,180
4,210
3,430
3,460
3,540
3,580
3,900
4,290
3,940
4,330
3,960
4,350
4,370
150

Fan
Air Flow (CFM)
Motor (HP)

(2)7.5
(2)10
(2)7.5
(2)10
(2)7.5
(2)10
(2)15
(2)20
(2)15
(2)15
(2)20
(2)20
(2)25
(2)25
(2)30

98,600
107,900
96,900
106,200
100,100
109,700
124,900
137,000
122,600
120,700
134,100
132,100
144,000
141,600
150,100

Dimensions
H

13 3/4
13 3/4
14 3/4
14 3/4
12 3/4
12 3/4
12 3/4
12 3/4
13 3/4
14 3/4
13 3/4
14 3/4
13 3/4
14 3/4
14 3/4
1 9

8 1/2
8 1/2
9 1/2
9 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
8 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9

9 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

43

2-1/2"

3/8"

F Heaviest section is upper section.

Models: AT/UT/USS 29-228 to 29-928


Two-Cell Cooling Towers

SWING OUT RADIUS


OF MOTOR COVER
30 5/8"

30 5/8"
ACCESS DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

21-3/8"

2"
T

(2) 8 BFW/GROOVED
INLET

83-7/8"

H
P
66-1/4"

(2) 8 BFW/GROOVED
OUTLET

83-7/8"

23-1/8"

(2) 3 FPT OVERFLOW

Model No.

AT-29-128
AT-29-228U
AT-29-228L
AT-29-228
AT-29-328E
AT-29-328U
AT-29-328L
AT-29-328
AT-29-428
AT-29-528E
AT-29-528U
AT-29-528L
AT-29-528
AT-29-628
AT-29-728
AT-29-828
AT-29-928
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

446
502
563
633
506
563
622
678
698
535
592
661
726
757
787
802
830

167-3/4"

3-5/8"

3/8"

(2) 2 MPT MAKE-UP

5-1/4"

7-1/2"
8' 5 1/2"

(2) 3 FPT DRAIN

158-3/4"

14-7/8"

2-1/2"
28' 2"

Weights (LBS)
Shipping

Operating

11,140
11,960
12,020
12,180
11,200
11,360
11,440
11,480
12,260
12,860
12,920
13,080
13,160
12,300
13,200
12,340
13,240
300

20,160
20,980
21,040
21,200
20,220
20,380
20,460
20,500
21,280
21,880
21,940
22,100
22,180
21,320
22,220
21,360
22,260
300

Heaviest
SectionF

3,680
4,090
4,120
4,200
3,710
3,790
3,830
3,850
4,240
4,540
4,570
4,650
4,690
4,260
4,710
4,280
4,730
150

Fan
Air Flow (CFM)
Motor (HP)

(2)7.5
(2)7.5
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)25
(2)25
(2)30
(2)30

112,300
110,700
121,100
137,800
123,000
140,200
153,600
164,700
150,600
108,800
119,200
135,600
148,300
161,600
159,000
171,200
168,200

Dimensions
H

12 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
13 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
13 6-3/4
14 6-3/4
13 6-3/4
14 6-3/4
1 9

7 1/2
8 1/2
8 1/2
8 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
8 1/2
9 1/2
1 9

8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

44

Models: AT/UT/USS 210-124 to 210-924


Two-Cell Cooling Towers

ACCESS DOORS SWING


INSIDE UNIT
ACCESS DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

7"

T
2"

(2) 8 BFW/GROOVED
INLET

71-7/8"
H

P
74-1/4"
(2) 8 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW
(2) 2 MPT MAKE-UP

25-1/4"
16-7/8"
7-1/4"

71-7/8"

(2) 3 FPT DRAIN


134-3/4"
5-1/4"

3-5/8"
9' 9-3/4"

143-3/4"

3/8"

2-1/2"
24' 2"

Model No.

AT-210-124L
AT-210-124
AT-210-224E
AT-210-224U
AT-210-224L
AT-210-224
AT-210-324
AT-210-424
AT-210-524
AT-210-624E
AT-210-624U
AT-210-624L
AT-210-624
AT-210-724
AT-210-824
AT-210-924
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

529
618
455
553
611
651
676
684
722
555
644
701
746
760
785
820

Weights (LBS)
Shipping

Operating

13,860
13,860
12,760
12,900
13,000
13,100
13,960
13,300
14,060
14,560
14,700
14,800
14,900
14,260
15,100
15,600
1,400

24,940
24,940
23,840
23,980
24,080
24,180
25,040
24,380
25,140
25,640
25,780
25,880
25,980
25,340
26,180
26,680
1,400

4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)40

127,300
144,500
129,400
147,000
161,100
172,900
158,300
183,500
169,700
125,300
142,300
155,800
167,200
179,900
176,900
185,600

15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
1 9-1/2

9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2

10 1
10 1
9 1
9 1
9 1
9 1
10 1
9 1
10 1
11 1
11 1
11 1
11 1
10 1
11 1
11 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

45

Heaviest
SectionF

F Heaviest section is upper section.

Models: AT/UT/USS 210-136 to 210-936


Two-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

7"

2"

ACCESS
DOOR

ACCESS
DOOR

(2) 10 BFW/GVD
INLET

108"

P
74-1/4"
(2) 10 BFW/GVD
OUTLET
(2) 3 FPT OVERFLOW

108"

25-1/4"

Model No.

AT-210-136U
AT-210-136L
AT-210-136
AT-210-236L
AT-210-236
AT-210-336U
AT-210-336L
AT-210-336
AT-210-436L
AT-210-436
AT-210-536
AT-210-636
AT-210-736U
AT-210-736L
AT-210-736
AT-210-836
AT-210-936
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

580
701
779
727
839
667
790
873
840
890
941
997
921
987
1,044
1,093
1,140

216

3-5/8"

3/8"

(2) 2 MPT MAKE-UP

5-1/4

8-1/2"
9' 9-3/4"

(2) 3 FPT DRAIN

207

16-7/8"

2-1/2
36' 2-1/2"

Weights (LBS)
Shipping

Operating

17,960
18,100
18,200
20,600
20,740
19,340
19,480
19,580
18,300
18,500
19,680
19,880
20,840
20,940
21,140
20,380
21,640
1,400

34,770
34,910
35,010
37,410
37,550
36,150
36,290
36,390
35,110
35,310
36,490
36,690
37,650
37,750
37,950
37,190
38,450
1,400

Heaviest
SectionF

5,640
5,710
5,760
6,960
7,030
6,330
6,400
6,450
5,810
5,910
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

(2)10
(2)15
(2)20
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)30
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)40

172,000
195,600
214,400
166,500
189,400
169,400
192,600
211,000
230,200
244,100
226,300
239,600
207,500
222,600
235,800
262,300
258,100

14 5-1/4
14 5-1/4
14 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
1 9-1/2

8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2

9 0
9 0
9 0
11 0
11 0
10 0
10 0
10 0
9 0
9 0
10 0
10 0
11 0
11 0
11 0
10 0
11 0

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


F Heaviest section is upper section.
Height includes fan guard which ships factory mounted.

46

Models: AT/UT/USS 212-59 to 212-99


Two-Cell Cooling Towers

ACCESS DOOR

30-5/8"
SWING OUT RADIUS OF MOTOR COVER
30-5/8"
ACCESS DOOR

21-3/8"

21-3/8"

(2) 6 BFW/GROOVED
INLET

66-3/8"

ACCESS
DOOR

ACCESS
DOOR

T
2"
H
P

56-1/4"

(2) 3 MPT
OVERFLOW

(2) 6 BFW/GROOVED
OUTLET

62-7/8"

(2) 3 MPT
DRAIN

66-5/8"
67-5/8"

5-1/8"
12' 4-7/8"

Model No.

AT-212-49
AT-212-59L
AT-212-59
AT-212-69
AT-212-79U
AT-212-79L
AT-212-79
AT-212-89
AT-212-99E
AT-212-99U
AT-212-99L
AT-212-99
UT Addition

NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

219
179
225
247
203
250
277
302
262
287
315
344

71-7/8"

16-7/8"
6-1/2"
3-5/8"
1-3/8"

Weights (LBS)
Shipping

Operating

6,920
6,080
6,120
6,200
6,480
6,520
6,600
6,660
6,960
7,040
7,100
7,240
300

11,000
10,160
10,200
10,280
10,560
10,600
10,680
10,740
11,040
11,120
11,180
11,320
300

Heaviest
SectionF

2,410
1,990
2,010
2,050
2,190
2,210
2,250
2,280
2,430
2,470
2,500
2,570
150

8' 5-1/2"

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

(2)3
(2)3
(2)5
(2)7.5
(2)3
(2)5
(2)7.5
(2)10
(2)5
(2)7.5
(2)10
(2)15

43,800
45,200
53,100
60,500
44,500
52,300
59,400
65,100
51,400
58,500
64,000
72,800

13 4-1/4
11 4-1/4
11 4-1/4
11 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
1 1

8 8
6 8
6 8
6 8
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
1 1

7 10-1/2
9 10-1/2
7 10-1/2
7 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


F Heaviest section is upper section.
Height includes fan guard which ships factory mounted.

47

23-1/8"

50-5/8"

(2) 2 MPT
MAKE-UP

Models: AT/UT/USS 212-024 to 212-924


Two-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

7"

ACCESS
DOOR

2"

ACCESS
DOOR

(2) 8 BFW/GROOVED
INLET

71-7/8"
H

P
74-1/4"

(2) 8 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW

25-1/4"

(2) 2 MPT MAKE-UP

71-7/8"

16-7/8"

134-3/4"

7-1/4"

11' 10"

Model No.

AT-212-024U
AT-212-024L
AT-212-024
AT-212-124L
AT-212-124
AT-212-224
AT-212-324
AT-212-424
AT-212-524
AT-212-624E
AT-212-624U
AT-212-624L
AT-212-624
AT-212-724
AT-212-824
AT-212-924
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

560
667
729
633
740
782
807
828
868
674
775
843
908
922
963
1,030

(2) 3 FPT DRAIN

5-1/4"

3-5/8"
143-3/4"

3/8"

2-1/2"
24' 2"

Weights (LBS)
Shipping

Operating

14,560
14,840
14,940
15,640
15,920
15,040
16,020
15,240
16,120
16,620
16,900
17,000
17,100
16,320
17,300
17,800
1,400

26,980
27,260
27,360
28,060
28,340
27,460
28,440
27,660
28,540
29,040
29,320
29,420
29,520
28,740
29,720
30,220
1,400

Heaviest
SectionF

4,860
5,000
5,050
5,400
5,540
5,100
5,590
5,200
5,640
5,890
6,030
6,080
6,130
5,740
6,230
6,480
700

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

(2)10
(2)15
(2)20
(2)10
(2)15
(2)25
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)40

143,100
162,700
178,300
140,900
160,100
191,500
175,300
202,900
188,000
138,600
157,500
172,400
184,800
199,000
195,700
214,300

14 6-1/4
14 6-1/4
14 6-1/4
15 6-1/4
15 6-1/4
14 6-1/4
15 6-1/4
14 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
1 9-1/2

8 4
8 4
8 4
9 4
9 4
8 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
10 4
1 9-1/2

9 2
9 2
9 2
10 2
10 2
9 2
10 2
9 2
10 2
11 2
11 2
11 2
11 2
10 2
11 2
11 2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

48

Models: AT/UT/USS 212-128 to 212-928


Two-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

7"

2"

ACCESS
DOOR

ACCESS
DOOR

(2) 10 BFW/GROOVED
INLET

83-7/8"

P
86-1/4"
(2) 10 BFW/GROOVED
OUTLET

83-7/8"

25-1/4"

(2) 3 FPT OVERFLOW

158-3/4"

16-7/8"

Model No.

AT-212-128E
AT-212-128U
AT-212-128L
AT-212-128
AT-212-228U
AT-212-228L
AT-212-228
AT-212-328
AT-212-428
AT-212-528E
AT-212-528U
AT-212-528L
AT-212-528
AT-212-628
AT-212-728
AT-212-828
AT-212-928
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

598
717
787
850
687
810
877
900
942
741
853
921
987
1,002
1,049
1,097
1,147

Weights (LBS)
Shipping

Operating

16,000
16,140
16,260
16,380
17,320
17,460
17,580
16,520
17,700
18,360
18,500
18,620
18,740
17,840
18,880
18,360
19,400
1,400

30,660
30,800
30,920
31,040
31,980
32,120
32,240
31,180
32,360
33,020
33,160
33,280
33,400
32,500
33,540
33,020
34,060
1,400

Heaviest
SectionF

5,360
5,430
5,490
5,550
6,020
6,090
6,150
5,620
6,210
6,540
6,610
6,670
6,730
6,280
6,800
6,540
7,060
700

2-1/2"
28' 2"

Dimensions

Fan
Motor
(HP)

Air Flow (CFM)

(2)10
(2)15
(2)20
(2)25
(2)10
(2)15
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)40
(2)40

155,600
176,900
194,000
208,400
153,200
174,000
190,900
220,700
204,700
150,600
171,200
187,600
201,200
216,700
213,200
237,200
233,100

15 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
15 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
1 9-1/2

8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
1 9-1/2

10 1
10 1
10 1
10 1
11 1
11 1
11 1
10 1
11 1
12 1
12 1
12 1
12 1
11 1
12 1
11 1
12 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

49

167-3/4"

3-5/8"

3/8"

(2) 3 FPT DRAIN

5-1/4"

8-1/2"
11' 10"

(2) 2 MPT MAKE-UP

F Heaviest section is upper section.

Models: AT/UT/USS 212-036 to 212-936


Two-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

7"

T
2"

(2) 10 BFW/GROOVED
INLET

108"
H

P
86-1/4"
(2) 10 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW
25-1/4"

(2) 2 MPT MAKE-UP

108"

16-7/8"

207"

8-1/2"

5-1/4"

3-5/8"
11' 10"

Model No.

AT-212-036L
AT-212-036
AT-212-136E
AT-212-136U
AT-212-136L
AT-212-136
AT-212-136M
AT-212-236U
AT-212-236L
AT-212-236
AT-212-336L
AT-212-336
AT-212-436
AT-212-536
AT-212-636
AT-212-736
AT-212-836
AT-212-936
UT Addition
NOTE:


(1)
(2)
(3)
(4)

216"

3/8"

Nominal
Tonnage

977
1,092
877
994
1,051
1,107
1,219
1,035
1,145
1,213
1,161
1,227
1,283
1,350
1,409
1,448
1,513
1,570

(2) 3 FPT DRAIN


2-1/2"
36' 2-1/2"

Weights (LBS)
Shipping

Operating

22,340
22,460
20,780
20,900
21,000
21,220
21,740
23,820
23,940
24,040
22,560
22,780
24,260
23,300
24,780
23,420
24,900
25,120
2,400

40,880
41,000
39,320
39,440
39,540
39,760
40,280
42,360
42,480
42,580
41,100
41,320
42,800
41,840
43,320
41,960
43,440
43,660
2,400

Heaviest
SectionF

7,480
7,540
6,700
6,760
6,810
6,920
7,180
8,220
8,280
8,330
7,590
7,700
8,440
7,960
8,700
8,020
8,760
8,870
1,200

Fan
Motor
(HP)

Air Flow
(CFM)

(2)15
(2)20
(2)15
(2)20
(2)25
(2)30
(2)40
(2)15
(2)20
(2)25
(2)25
(2)30
(2)30
(2)40
(2)40
(2)50
(2)50
(2)60

216,900
237,300
220,200
241,200
259,200
274,700
300,900
213,300
233,600
250,800
254,700
270,100
265,800
295,500
290,700
317,100
311,400
329,900

Dimensions
H

16 6-1/4
16 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
1 3-1/2

9 4
9 4
8 4
8 4
8 4
8 4
8 4
10 4
10 4
10 4
9 4
9 4
10 4
9 4
10 4
9 4
10 4
10 4
1 3-1/2

11 1
11 1
10 1
10 1
10 1
10 1
10 1
12 1
12 1
12 1
11 1
11 1
12 1
11 1
12 1
11 1
12 1
12 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

50

Models: AT/UT/USS 212-0140 to 212-1640


Two-Cell Cooling Towers

AC C ES S DO OR

ACCESS DOORS SWING INSIDE UNIT

ACC E S S DO OR

7"

ACCESS
DOOR

2"
T

ACCESS
DOOR
(2) 10 BFW/GROOVED
INLET

120"
H

P
86-1/4"

(2) 10 BFW/GROOVED
OUTLET
120"

25-1/4"

Model No.

AT-212-0140
AT-212-0240
AT-212-0340
AT-212-0440
AT-212-0540
AT-212-0640
AT-212-0740
AT-212-0840
AT-212-0940
AT-212-1040
AT-212-1140
AT-212-1240
AT-212-1340
AT-212-1440
AT-212-1540
AT-212-1640
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

918
1,013
1,088
1,250
1,357
1,073
1,170
1,246
1,396
1,515
1,143
1,235
1,310
1,457
1,576
1,635

240"

3-5/8"

2-1/2
40'-2-1/2"

Weights (LBS)
Shipping

Operating

22,480
22,580
22,800
23,320
23,440
23,940
24,040
24,260
24,780
24,900
25,740
25,840
26,060
26,580
26,700
26,920
2,400

43,280
43,380
43,600
44,120
44,240
44,740
44,840
45,060
45,580
45,700
46,540
46,640
46,860
47,380
47,500
47,720
2,400

Heaviest
SectionF

7,210
7,260
7,370
7,630
7,690
7,940
7,990
8,100
8,360
8,420
8,840
8,890
9,000
9,260
9,320
9,430
1,200

Fan
Motor
(HP)

Air Flow
(CFM)

(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)60

246,500
264,600
280,300
306,600
329,000
242,400
260,000
275,300
300,900
322,600
238,300
255,700
270,900
296,200
317,300
336,300

Dimensions
H

15 6-1/2
15 6-1/2
15 6-1/2
15 6-1/2
15 6-1/2
16 6-1/2
16 6-1/2
16 6-1/2
16 6-1/2
16 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
1 3-1/2

8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
10 4
10 4
1 3-1/2

10 1
10 1
10 1
10 1
10 1
11 1
11 1
11 1
11 1
11 1
12 1
12 1
12 1
12 1
12 1
12 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

51

(2) 2 MPT MAKE-UP

234-3/4"

8-1/2"
3/8"

(2) 3 FPT DRAIN

231"

16-7/8"

11'-10"

(2) 3 FPT OVERFLOW

F Heaviest section is upper section.

Models: AT/UT/USS 214-0148 to 214-1248


Two-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

7"

ACCESS
DOOR

ACCESS
DOOR
T

(2) 14 BFW/GROOVED
OUTLET

2"

142-1/2"

142-1/2"

P
99-3/8"

(2) 14 BFW/GROOVED
OUTLET

26"
9"
4-1/8"

142-1/2"

(2) 4 FPT
OVERFLOW

212-3/4"

285"
13' 11-1/4"

Model No.

AT-214-0148U
AT-214-0148L
AT-214-0148
AT-214-0248
AT-214-0348
AT-214-0448L
AT-214-0448
AT-214-0548
AT-214-0648E
AT-214-0648U
AT-214-0648L
AT-214-0648
AT-214-0748
AT-214-0848
AT-214-0948L
AT-214-0948
AT-214-1048
AT-214-1148
AT-214-1248*
UT Addition
NOTE:


(1)
(2)
(3)
(4)

2-1/2"

3/8"

Nominal
Tonnage

1,205
1,336
1,410
1,527
1,641
1,514
1,637
1,713
1,383
1,517
1,589
1,748
1,860
1,960
1,863
1,978
2,075
2,230
2,359

(2) 3 MPT
MAKE-UP

(2) 4 FPT
DRAIN

276"

17-3/8"

47' 8-1/2"

Weights (LBS)
Shipping

Operating

32,640
32,740
32,780
33,080
33,780
36,800
36,900
36,940
34,720
34,820
34,860
35,160
37,240
37,940
35,860
36,200
38,280
38,760
39,640
2,500

64,340
64,440
64,480
64,780
65,480
68,500
68,600
68,640
66,420
66,520
66,560
66,860
68,940
69,640
67,560
67,900
69,980
70,460
71,340
2,500

Heaviest
SectionF

10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,900
13,250
12,210
12,380
13,420
13,660
14,100
1,250

Fan
Motor
(HP)

Air Flow
(CFM)

(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)40
(2)50
(2)50
(2)60
(2)60
(2)75
(2)100

313,500
336,700
357,000
391,200
420,400
301,100
323,100
343,300
308,800
331,200
351,100
384,300
378,000
405,900
412,500
436,800
429,900
471,200
505,100

Dimensions
H

17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2

9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2

11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

* Model available with gear drive only. Motors and access doors located on 1311-1/4 unit ends. Super Low Sound Fan is not available on this unit.

52

Models: AT/UT/USS 214-552 to 214-952


Two-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

(2) 14 BFW/GROOVED
INLET

2"

ACCESS
DOOR

154-1/2"

123-3/8"

(2) 14 BFW/GROOVED
OUTLET

26"
(2) 4 FPT
OVERFLOW

154-1/2"
17-3/8"

230-5/8"
9"

4-1/8"
13' 11-1/4"

Model No.

AT-214-552
AT-214-652
AT-214-752
AT-214-852
AT-214-952
UT Addition
NOTE:


(1)
(2)
(3)
(4)

2-1/2"
51' 8-1/4"

1,971
2,119
2,245
2,452
2,622

Weights (LBS)
Shipping

Operating

49,200
49,320
49,520
50,160
50,200
D

82,860
82,980
83,180
83,820
83,860
4,800

Heaviest
SectionF

17,660
17,720
17,820
18,140
18,160
D

Fan
Motor
(HP)

Air Flow
(CFM)

(4)20
(4)25
(4)30
(4)40
(4)50

393,500
422,100
446,800
488,700
523,700

Dimensions
H

22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2

12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2

16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

53

308-7/8"

3/8"

Nominal
Tonnage

(2) 3 MPT
MAKE-UP

(2) 4 FPT
DRAIN

299-7/8"

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

Models: AT/UT/USS 215-29 to 215-99


Two-Cell Cooling Towers

ACCESS
DOOR
30-5/8"

SWING OUT RADIUS OF MOTOR COVER

30-5/8"

ACCESS
DOOR

21-3/8"

21-3/8"

ACCESS
DOOR

ACCESS
DOOR

(2) 6 BFW/GROOVED
INLET

T
2"

45"
H

56-1/4"

(2) 3 MPT
OVERFLOW
(2) 2 MPT
MAKE-UP
(2) 3 MPT
DRAIN

8' 5-1/2"

Model No.

AT-215-29L
AT-215-29
AT-215-39
AT-215-49
AT-215-59U
AT-215-59L
AT-215-59
AT-215-69
AT-215-79E
AT-215-79U
AT-215-79L
AT-215-79
AT-215-89
AT-215-99
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

217
274
297
319
247
304
331
358
267
319
346
373
393
414

5-1/8"
15' 4-7/8"

1- 3/8"

Weights (LBS)
Shipping

Operating

6,860
6,900
6,980
7,040
7,320
7,360
7,440
7,500
7,860
7,900
7,980
8,040
7,620
8,160
300

11,700
11,740
11,820
11,880
12,160
12,200
12,280
12,340
12,700
12,740
12,820
12,880
12,460
13,000
300

Heaviest
SectionF

2,260
2,280
2,320
2,350
2,490
2,510
2,550
2,580
2,760
2,780
2,820
2,850
2,640
2,910
150

Fan
Motor
(HP)

Air Flow
(CFM)

(2)3
(2)5
(2)7.5
(2)10
(2)3
(2)5
(2)7.5
(2)10
(2)3
(2)5
(2)7.5
(2)10
(2)15
(2)15

53,200
62,600
71,400
78,300
52,500
61,600
70,200
76,900
51,600
60,600
69,100
75,700
87,500
86,000

(2) 6 BFW/GROOVED
OUTLET

23-1/8"

68-5/8"
80-7/8"

14-7/8"

84-5/8"

6-1/2"

85-5/8"

3-5/8"

89-7/8"

Dimensions
H

11 4-1/4
11 4-1/4
11 4-1/4
11 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
12 4-1/4
13 4-1/4
1 5

6 8
6 8
6 8
6 8
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
7 8
8 8
1 5

7 10-1/2
7 10-1/2
7 10-1/2
7 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
8 10-1/2
9 10-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

* Model available with gear drive only. Motors and access doors located on 13 11-1/4 unit ends. Super Low Sound Fan is not available on this unit.

54

Models: AT/UT/USS 217-59 to 217-99


Two-Cell Cooling Towers

ACCESS DOOR

30-5/8"

SWING OUT RADIUS OF MOTOR COVER

30-5/8"
ACCESS DOOR

21-3/8"

21-3/8"

ACCESS
DOOR

ACCESS
DOOR

(2) 8 BFW/GROOVED
INLET

T
2"

50-3/4"

P
60-1/4"

(2) 3 MPT
OVERFLOW
(2) 2 MPT
MAKE-UP
(2) 3 MPT
DRAIN

8 11-1/2"

Model No.

AT-217-59U
AT-217-59L
AT-217-59
AT-217-69E
AT-217-69U
AT-217-69L
AT-217-69
AT-217-79
AT-217-89E
AT-217-89U
AT-217-89L
AT-217-89
AT-217-99
UT Addition

Nominal
Tonnage

5-1/8"
17' 4-1/8"

1-3/8"

Weights (LBS)
Shipping

Operating

308
8,500
14,180
362
8,580
14,260
399
8,640
14,320
270
7,960
13,640
324
8,040
13,720
OUT RADIUS OF MOTOR COVER
356 SWING8,100
13,780
416
8,240
13,920
464
8,780
14,460
330
9,120
14,800
381
9,200
14,880
418
9,260
14,940
484
9,400
15,080
530ACCESS 9,500 ACCESS 15,180
DOOR
DOOR
300
300 T

Heaviest
SectionF

2,940
2,980
3,010
ACCESS DOOR
2,670
2,710
2,740
2,810
30-5/8"
3,080
3,250
3,290
21-3/8"
3,320
3,390
3,440
150

Fan Motor
(HP)

Air Flow
(CFM)

(2)5
(2)7.5
(2)10
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)20

70,600
80,200
87,800
71,700
81,500
89,300
101,500
99,500
69,400
78,900
86,400
97,900
107,100

(2) 8 BFW/GROOVED
INLET

2"

NOTE:


(1)
(2)
(3)
(4)

80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"

23-1/8"
14-7/8"
7-1/2"
3-5/8"

Dimensions
H

13 3-3/8
13 3-3/8
13 3-3/8
12 3-3/8
12 3-3/8
12 3-3/8
12 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
1 9

8 3-1/8
8 3-1/8
8 3-1/8
7 3-1/8
730-5/8"
3-1/8
7 3-1/8
7 3-1/8
8 3-1/8
ACCESS DOOR
9 3-1/8
9 3-1/8
21-3/8"
9 3-1/8
9 3-1/8
9 3-1/8
1 9

9 3-1/2
9 3-1/2
9 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2

50-3/4"

H cooling tower system to prevent build-up of impurities in the recirculated water.


An adequately sized bleed line must be installed in the
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
P
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

60-1/4"

F Heaviest section is upper section.


(2) 3 MPT
OVERFLOW
(2) 2 MPT
MAKE-UP
(2) 3 MPT
DRAIN

10 5-1/2

55

(2) 8 BFW/GROOVED
OUTLET

1-3/8"

5-1/8"
17' 4-1/8"

(2) 8 BFW/GROOVED
OUTLET

80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"

23-1/8"
14-7/8"
7-1/2"
3-5/8"

8 11-1/2"

5-1/8"
17' 4-1/8"

97-1/4"
101-1/2"

3-5/8"

Models: AT/UT/USS 217-111 to 217-911


1-3/8"

Two-Cell Cooling Towers

ACCESS DOOR

30-5/8"

SWING OUT RADIUS OF MOTOR COVER

30-5/8"
ACCESS DOOR

21-3/8"

21-3/8"

ACCESS
DOOR

ACCESS
DOOR

(2) 8 BFW/GROOVED
INLET

T
2"

50-3/4"

P
60-1/4"

(2) 3 MPT
OVERFLOW
(2) 2 MPT
MAKE-UP
(2) 3 MPT
DRAIN

1-3/8"

10 5-1/2

Model No.

AT-217-111L
AT-217-111
AT-217-211L
AT-217-211
AT-217-311
AT-217-411L
AT-217-411
AT-217-511U
AT-217-511L
AT-217-511
AT-217-611
AT-217-711
AT-217-811
AT-217-911L
AT-217-911
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

316
379
347
409
447
408
467
385
444
480
516
545
576
602
634

5-1/8"
17' 4-1/8"

Weights (LBS)
Shipping

Operating

9,060
9,140
9,700
9,780
9,840
9,200
9,340
10,400
10,480
10,540
9,980
10,680
10,080
10,780
10,840
300

15,660
15,740
16,300
16,380
16,440
15,800
15,940
17,000
17,080
17,140
16,580
17,280
16,680
17,380
17,440
300

Heaviest
SectionF

3,060
3,100
3,380
3,420
3,450
3,130
3,200
3,730
3,770
3,800
3,520
3,870
3,570
3,920
3,950
150

Fan Motor
(HP)

Air Flow
(CFM)

(2)5
(2)7.5
(2)5
(2)7.5
(2)10
(2)10
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)20
(2)20
(2)25

80,700
91,800
79,600
90,500
99,100
100,700
114,600
78,200
88,900
97,400
112,500
110,600
123,000
120,900
129,700

(2) 8 BFW/GROOVED
OUTLET

80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"

23-1/8"
14-7/8"
7-1/2"
3-5/8"

Dimensions
H

12 3-3/8
12 3-3/8
13 3-3/8
13 3-3/8
13 3-3/8
12 3-3/8
12 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
13 3-3/8
14 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
1 9

7 3-1/8
7 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
7 3-1/8
7 3-1/8
9 3-1/8
9 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
9 3-1/8
1 9

8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
10 3-1/2
8 3-1/2
8 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

56

Models: AT/UT/USS 217-414 to 217-912


Two-Cell Cooling Towers

ACCESS DOOR

30-5/8"

SWING OUT RADIUS OF MOTOR COVER

30-5/8"

ACCESS DOOR

21-3/8"

21-3/8"

ACCESS
DOOR

ACCESS
DOOR

(2) 8 BFW/GROOVED
INLET

T
2"

50-3/4"

P
5 1/4"

(2) 8 BFW/GROOVED
OUTLET

(2) 3 MPT OVERFLOW


(2) 2 MPT MAKE-UP
(2) 3 MPT DRAIN

11 11-3/4"

Model No.

AT-217-412E
AT-217-412U
AT-217-412L
AT-217-412
AT-217-512U
AT-217-512L
AT-217-512
AT-217-612
AT-217-712E
AT-217-712U
AT-217-712L
AT-217-712
AT-217-812
AT-217-912L
AT-217-912
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

394
447
499
550
446
499
564
622
474
524
585
645
665
688
709

5-1/8"

1-3/8"

17' 4-1/8"

Weights (LBS)
Shipping

80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"

Heaviest
SectionF

Operating

10,160
17,880
3,430
10,220
17,940
3,460
10,380
18,100
3,540
10,460
18,180
3,580
10,880
18,600
3,790
10,940
18,660
3,820
11,100
18,820
3,900
11,180
18,900
3,940
ACCESS DOOR
SWING OUT RADIUS
OF MOTOR COVER4,180
11,660
19,380
11,720
19,440
4,210
11,880
19,600
4,29030-5/8"
11,960
19,680
4,330
11,220
18,940
3,960
12,000
19,720
4,350
12,040
19,760
4,370
21-3/8"
300
300
150

Fan Motor
(HP)

Air Flow
(CFM)

(2)7.5
(2)10
(2)15
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)25
(2)25
(2)30

99,600
109,100
124,300
136,200
98,100
107,300
122,000
133,500
96,500
105,600
120,100
131,400
143,200
140,800
149,300

23-1/8"
14-7/8"
7-1/2"
3-5/8"

Dimensions
H

12 3-3/8
12 3-3/8
12 3-3/8
12 3-3/8
13 3-3/8
13 3-3/8
13 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
1 9

7 3-1/8
7 3-1/8
7 3-1/8
7 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
30-5/8"
9 3-1/8
9 3-1/8
9 3-1/8
ACCESS
DOOR
9 3-1/8
8 3-1/8
9 3-1/8
9 3-1/8
21-3/8"
1 9

ACCESS

ACCESS
(2) 8 BFW/GROOVED
An adequately
sized bleed line
build-up of impurities in the recirculated water.
DOORmust be installed in the cooling tower system to prevent
DOOR
INLET
Do not use catalog drawings for certified prints. Dimensions
and weights are subject to
change.
T
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at
and 78 degree wet-bulb temperature.
50-3/4"
2" 95 degree entering water temperature, 85 degree leaving water temperature,

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


P
5 6-1/4"

(2) 8 BFW/GROOVED
OUTLET

(2) 3 MPT OVERFLOW


(2) 2 MPT MAKE-UP
(2) 3 MPT DRAIN

57

8 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2

13 11-3/4"

1-3/8"

5-1/8"
17' 4-1/8"

80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"

23-1/8"
14-7/8"
7-1/2"
3-5/8"

11 11-3/4"

1-3/8"

17' 4-1/8"

3-5/8"

Models: AT/UT/USS 217-114 to 217-914


Two-Cell Cooling Towers

ACCESS DOOR

30-5/8"

SWING OUT RADIUS OF MOTOR COVER

30-5/8"

ACCESS DOOR

21-3/8"

21-3/8"

ACCESS
DOOR

ACCESS
DOOR

(2) 8 BFW/GROOVED
INLET

T
2"

50-3/4"

P
5 6-1/4"

(2) 8 BFW/GROOVED
OUTLET

(2) 3 MPT OVERFLOW


(2) 2 MPT MAKE-UP
(2) 3 MPT DRAIN

13 11-3/4"

Model No.

AT-217-114
AT-217-214U
AT-217-214L
AT-217-214
AT-217-314E
AT-217-314U
AT-217-314L
AT-217-314
AT-217-414
AT-217-514E
AT-217-514U
AT-217-514L
AT-217-514
AT-217-614
AT-217-714
AT-217-814
AT-217-914
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

435
490
551
621
494
551
608
664
685
525
581
649
714
744
773
787
815

5-1/8"

1-3/8"

17' 4-1/8"

Weights (LBS)
Shipping

Operating

11,080
11,900
11,960
12,120
11,140
11,300
11,380
11,420
12,200
12,800
12,860
13,020
13,100
12,240
13,140
12,280
13,180
300

20,100
20,920
20,980
21,140
20,160
20,320
20,400
20,440
21,220
21,820
21,880
22,040
22,120
21,260
22,160
21,300
22,200
300

80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"

Heaviest
SectionF

3,680
4,090
4,120
4,200
3,710
3,790
3,830
3,850
4,240
4,540
4,570
4,650
4,690
4,260
4,710
4,280
4,730
150

Fan Motor
(HP)

Air Flow
(CFM)

(2)7.5
(2)7.5
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)25
(2)25
(2)30
(2)30

112,300
110,600
121,100
137,700
123,000
140,200
153,600
164,700
150,600
108,800
119,100
135,500
148,300
161,500
158,900
171,100
168,200

23-1/8"
14-7/8"
7-1/2"
3-5/8"

Dimensions
H

12 9-3/8
13 9-3/8
13 9-3/8
13 9-3/8
12 9-3/8
12 9-3/8
12 9-3/8
12 9-3/8
13 9-3/8
14 9-3/8
14 9-3/8
14 9-3/8
14 9-3/8
13 9-3/8
14 9-3/8
13 9-3/8
14 9-3/8
1 9

7 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
7 3-1/8
7 3-1/8
7 3-1/8
7 3-1/8
8 3-1/8
9 3-1/8
9 3-1/8
9 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
1 9

8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

58

Models: AT/UT/USS 220-112 to 220-912


Two-Cell Cooling Towers

ACCESS DOOR

ACCESS DOORS SWING INSIDE UNIT

ACCESS DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

2"

(2) 8 BFW/GROOVED
INLET

58-7/8"

P
74-1/4"

(2) 3 MPT OVERFLOW

(2) 8 BFW/GROOVED
OUTLET

(2) 3 MPT DRAIN

25-1/4"

93-5/8"

(2) 2 MPT MAKE-UP

108-3/4"

16-7/8"

112-1/2"

7- 1/4"

113-1/2"

Model No.

AT-220-112L
AT-220-112
AT-220-212E
AT-220-212U
AT-220-212L
AT-220-212
AT-220-312
AT-220-412
AT-220-512
AT-220-612E
AT-220-612U
AT-220-612L
AT-220-612
AT-220-712
AT-220-812
AT-220-912
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

529
618
455
553
611
651
676
684
722
555
644
701
746
760
785
820

Weights (LBS)
Shipping

Operating

14,000
14,000
12,900
13,040
13,140
13,240
14,100
13,440
14,200
14,700
14,840
14,940
15,040
14,400
15,240
15,740
1,400

25,080
25,080
23,980
24,120
24,220
24,320
25,180
24,520
25,280
25,780
25,920
26,020
26,120
25,480
26,320
26,820
1,400

Heaviest
SectionF

4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700

Fan
Motor (HP)

Air Flow
(CFM)

(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)35

126,700
143,900
128,800
146,300
160,300
172,300
157,400
182,600
169,100
124,700
141,600
155,000
166,300
179,000
176,300
185,000

117-3/4"

Dimensions
H

15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
1 9-1/2

9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2

10 1
10 1
9 1
9 1
9 1
9 1
10 1
9 1
10 1
11 1
11 1
11 1
11 1
10 1
11 1
11 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

59

5-1/8"
20' 5/8"

1-3/8"

11' 11-3/4"

3-5/8"

F Heaviest section is upper section.

Models: AT/UT/USS 220-118 to 220-918


Two-Cell Cooling Towers

ACCESS DOOR

ACCESS DOORS SWING INSIDE UNIT

ACCESS DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

(2) 10 BFW/GROOVED
INLET

2"

58-7/8"

P
25-1/4"

86-1/4"

(2) 10 BFW/GROOVED
OUTLET

(2) 3 MPT OVERFLOW


(2) 2 MPT MAKE-UP

93-5/8"
108-3/4"

(2) 3 MPT DRAIN

16-7/8"

112-1/2"
113-1/2"
117-3/4"

5-1/8"

18' 0"

Model No.

AT-220-118U
AT-220-118L
AT-220-118
AT-220-218L
AT-220-218
AT-220-318U
AT-220-318L
AT-220-318
AT-220-418L
AT-220-418
AT-220-518
AT-220-618
AT-220-718U
AT-220-718L
AT-220-718
AT-220-818
AT-220-918
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

580
701
779
727
839
667
790
873
840
890
941
997
921
987
1,044
1,093
1,140

Weights (LBS)
Operating

17,820
17,960
18,060
20,600
20,600
19,200
19,340
19,440
18,160
18,360
19,540
19,740
20,700
20,800
21,000
20,240
21,500
1,400

34,630
34,770
34,870
37,410
37,410
36,010
36,150
36,250
34,970
35,170
36,350
36,550
37,510
37,610
37,810
37,050
38,310
1,400

3-5/8

20' 5/8"

1-3/8"

Shipping

8-1/2"

Heaviest
SectionF

5,640
5,710
5,760
7,030
7,030
6,330
6,400
6,450
5,810
5,910
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700

Fan
Motor (HP)

Air Flow
(CFM)

(2)10
(2)15
(2)20
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)30
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)40

171,200
194,700
213,600
165,700
188,600
168,600
191,700
210,000
229,100
243,000
225,200
238,600
206,500
221,600
234,800
261,000
256,800

Dimensions
H

15 5-1/4
15 5-1/4
15 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
17 5-1/4
1 9-1/2

8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2

10 0
10 0
10 0
12 0
12 0
11 0
11 0
11 0
10 0
10 0
11 0
11 0
12 0
12 0
12 0
11 0
12 0

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

60

Models: AT/UT/USS 224-018 to 224-918


Two-Cell Cooling Towers

ACCESS
DOOR
ACCESS DOORS SWING INSIDE UNIT

ACCESS
DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

T
71"

(2) 10 BFW/GROOVED
INLET

2"
H

P
98-1/4"

(2) 10 BFW/GROOVED
OUTLET

(2) 3 FPT OVERFLOW

25-1/4"
16-7/8"

117-7/8"
(2) 2 MPT MAKE-UP

Model No.

AT-224-018U
AT-224-018L
AT-224-018
AT-224-118
AT-224-218U
AT-224-218L
AT-224-218
AT-224-318
AT-224-418
AT-224-518E
AT-224-518U
AT-224-518L
AT-224-518
AT-224-618
AT-224-718
AT-224-818L
AT-224-818
AT-224-918
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

877
994
1,051
1,107
977
1,092
1,161
1,219
1,227
1,035
1,145
1,213
1,283
1,350
1,448
1,409
1,513
1,570

1- 3/8"

142"
24' 1-1/8"

Weights (LBS)
Shipping

Operating

20,840
20,960
21,060
21,280
22,400
22,520
22,620
21,800
22,840
23,880
24,000
24,100
24,320
23,360
23,480
24,840
24,960
25,180
2,400

39,380
39,500
39,600
39,820
40,940
41,060
41,160
40,340
41,380
42,420
42,540
42,640
42,860
41,900
42,020
43,380
43,500
43,720
2,400

Heaviest
SectionF

6,700
6,760
6,810
6,920
7,480
7,540
7,590
7,180
7,700
8,220
8,280
8,330
8,440
7,960
8,020
8,700
8,760
8,870
1,200

Fan
Motor (HP)

Air Flow
(CFM)

(2)15
(2)20
(2)25
(2)30
(2)15
(2)20
(2)25
(2)40
(2)30
(2)15
(2)20
(2)25
(2)30
(2)40
(2)50
(2)40
(2)50
(2)60

219,400
240,300
258,200
274,000
216,100
236,500
254,100
300,100
268,800
212,500
232,700
249,800
264,800
294,400
315,900
289,300
310,300
328,700

Dimensions
H

16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2

8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 3-1/2

11 1
11 1
11 1
11 1
12 1
12 1
12 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
12 1
13 1
13 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

61

3-5/8"

137-3/4"

5-1/8"
18' 0"

8-1/2"

133"
136-3/4"

(2) 3 FPT DRAIN

F Heaviest section is upper section.

Models: AT/UT/USS 224-720 to 224-920


Two-Cell Cooling Towers

ACCESS
DOOR
ACCESS DOORS SWING INSIDE UNIT

ACCESS
DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

T
71"

(2) 10 BFW/GROOVED
INLET

2"
H

P
98-1/4"

(2) 12 BFW/GROOVED
OUTLET

(2) 3 FPT OVERFLOW

25-1/4"
16-7/8"

117-7/8"
(2) 2 MPT MAKE-UP

137-3/4"

5-1/8"
1- 3/8"

Model No.

AT-224-120
AT-224-220
AT-224-320
AT-224-420L
AT-224-420
AT-224-520L
AT-224-520
AT-224-620U
AT-224-620L
AT-224-620
AT-224-720E
AT-224-720U
AT-224-720L
AT-224-720
AT-224-820
AT-224-920
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

893
986
1,061
1,220
1,324
1,046
1,142
1,219
1,366
1,482
1,119
1,210
1,284
1,428
1,545
1,603

Operating

22,300
22,400
22,620
23,140
23,260
23,760
23,860
24,080
24,600
24,720
25,560
25,660
25,880
26,400
26,520
26,740
2,400

43,100
43,200
43,420
43,940
44,060
44,560
44,660
44,880
45,400
45,520
46,360
46,460
46,680
47,200
47,320
47,540
2,400

142"

24' 1-1/8"

Weights (LBS)
Shipping

3-5/8"

136-3/4"

(2) 3 FPT DRAIN

20' 0"

9 1/2"

133"

Heaviest
SectionF

7,210
7,260
7,370
7,630
7,690
7,940
7,990
8,100
8,360
8,420
8,840
8,890
9,000
9,260
9,320
9,430
1,200

Fan
Motor (HP)

Air Flow
(CFM)

(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)60

244,300
262,200
277,900
304,000
326,100
240,300
257,800
272,900
298,300
319,800
236,300
253,500
268,500
293,700
314,700
333,500

Dimensions
H

16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2

8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
10 4
10 4
1 3-1/2

11 1
11 1
11 1
11 1
11 1
12 1
12 1
12 1
12 1
12 1
13 1
13 1
13 1
13 1
13 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

62

Models: AT/UT/USS 228-0124 to 228-1024


Two-Cell Cooling Towers

ACCESS
DOORS SWING
INSIDE UNIT

ACCESS
DOOR

ACCESS
DOOR

7"

ACCESS
DOOR

142-1/2"

2"

ACCESS
DOOR

(2) 14 BFW/GROOVED
INLET

99-3/8"
P
(2) 14 BFW/GROOVED OUTLET

138"

(2) 3 MPT MAKE-UP

26"

157-3/8"

(2) 4 MPT OVERFLOW

23' 9"

Model No.

AT-228-0124E
AT-228-0124U
AT-228-0124L
AT-228-0124
AT-228-0224
AT-228-0324L
AT-228-0324
AT-228-0424
AT-228-0524E
AT-228-0524U
AT-228-0524L
AT-228-0524
AT-228-0624
AT-228-0724
AT-228-0824U
AT-228-0824L
AT-228-0824
AT-228-0924
AT-228-1024*
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,198
1,329
1,402
1,520
1,633
1,508
1,630
1,706
1,376
1,510
1,582
1,740
1,855
1,969
1,853
1,952
2,067
2,221
2,350

5-1/8"
28' 3-5/8"

1- 3/8"

Weights (LBS)
Shipping

Operating

32,320
32,420
32,460
32,760
33,460
36,480
36,580
36,620
34,400
34,500
34,540
34,840
35,540
35,880
37,920
37,620
37,960
38,440
39,320
2,500

64,020
64,120
64,160
64,460
65,160
68,180
68,280
68,320
66,100
66,200
66,240
66,540
67,240
67,580
68,620
69,320
69,660
70,140
71,020
2,500

Heaviest
SectionF

10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,210
12,380
12,900
13,250
13,420
13,660
14,100
1,250

17-3/8"

161-5/8"

(2) 4 MPT DRAIN

Fan
Motor (HP)

Air Flow
(CFM)

(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)50
(2)60
(2)40
(2)50
(2)60
(2)75
(2)100

312,300
335,200
355,000
389,400
418,200
300,300
322,200
342,300
307,600
330,000
349,300
382,400
410,500
434,800
376,600
404,400
427,800
468,800
502,600

9"

162-1/8"
167-1/4"

4-1/8"

Dimensions
H

17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2

9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2

11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

* Model available with gear drive only. Motors and access doors located on 283-5/8 unit end. Super Low Sound Fan is not available on this unit.

63

Models: AT/UT/USS 228-526 to 228-926


Two-Cell Cooling Towers

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS DOORS SWING INSIDE UNIT

7"

ACCESS
DOOR

ACCESS
DOOR
T
(2) 14 BFW/GROOVED
INLET

2"

83-5/8"

P
123-3/8"

26"
(2) 14 BFW/GROOVED
OUTLET

(2) 4 MPT OVERFLOW

17-3/8"

138"

(2) 3 MPT MAKE-UP

9"
4"

157-1/4"

(2) 4 MPT DRAIN

161-1/2"
162-1/2"
5-1/8"
25' 8-7/8"

Model No.

AT-228-526
AT-228-626
AT-228-726
AT-228-826
AT-228-926
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,963
2,111
2,236
2,443
2,613

1-3/8"

Weights (LBS)
Shipping

Operating

48,940
49,060
49,260
49,900
49,940
D

82,600
82,720
82,920
83,560
83,600
4,800

Heaviest
SectionF

17,660
17,720
17,820
18,140
18,160
D

167-1/4"

28' 3-5/8"

Fan
Motor
(HP)

Air Flow
(CFM)

(4)20
(4)25
(4)30
(4)40
(4)50

392,000
420,400
445,100
486,800
521,700

Dimensions
H

22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2

12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2

16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

64

Models: AT/UT/USS 39-336 to 39-936


Three-Cell Cooling Towers

SWING OUT RADIUS OF MOTOR COVER


30-5/8"

30-5/8"

30-5/8"
ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

21-3/8"

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

T
(3) 8 BFW/GROOVED
INLET

71-7/8"

2"

H
P
66-1/4"

9"
5-1/4"

23-1/8"
14-7/8"

134-3/4"

3-5/8"

143-3/4"

Model No.

AT-39-136
AT-39-236
AT-39-336L
AT-39-336
AT-39-436
AT-39-536
AT-39-636U
AT-39-636L
AT-39-636
AT-39-736
AT-39-836
AT-39-936E
AT-39-936U
AT-39-936L
AT-39-936
UT Addition
NOTE:


(1)
(2)
(3)
(4)

2-1/2"

725
800
605
686
765
843
682
763
862
951
1,016
893
984
1,050
1,082

36' 4-1/4"

Weights (LBS)
Shipping

Operating

17,550
17,640
15,300
15,390
15,630
15,750
16,380
16,470
16,710
16,830
16,890
17,880
18,000
18,060
18,120
450

29,130
29,220
26,880
26,970
27,210
27,330
27,960
28,050
28,290
28,410
28,470
29,460
29,580
29,640
29,700
450

Heaviest
SectionF

4,180
4,210
3,430
3,460
3,540
3,580
3,790
3,820
3,900
3,940
3,960
4,290
4,330
4,350
4,370
150

Fan
Motor (HP)

Air Flow
(CFM)

(3)7.5
(3)10
(3)7.5
(3)10
(3)15
(3)20
(3)7.5
(3)10
(3)15
(3)20
(3)25
(3)15
(3)20
(3)25
(3)30

146,100
159,900
150,900
165,200
188,200
206,200
148,600
162,500
184,900
202,200
217,100
181,900
198,900
213,200
226,200

Dimensions
H

14 6-3/4
14 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
1 9

9 1/2
9 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
1 9

10 9-1/2
10 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

65

(3) 2 MPT MAKE-UP


5-1/8"

3/8"

Nominal
Tonnage

(3) 3 FPT OVERFLOW


(3) 3 FPT DRAIN

71-7/8"

7-1/2"

8' 5-1/2"

(3) 8 BFW/GROOVED
OUTLET

F Heaviest section is upper section.

Models: AT/UT/USS 39-242 to 39-942


Three-Cell Cooling Towers

SWING OUT RADIUS OF MOTOR COVER


30-5/8"

30-5/8"

30-5/8"

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

21-3/8"

2
T

(3) 8 BFW/GROOVED
INLET

83-7/8"

H
P
66-1/4"

(3) 8 BFW/GROOVED
OUTLET

23-1/8"

83-7/8"

(3) 3 FPT OVERFLOW

7-1/2"

5-1/4

3-5/8"
8' 5-1/2"

Model No.

AT-39-142
AT-39-242L
AT-39-242
AT-39-342
AT-39-442L
AT-39-442
AT-39-542L
AT-39-542
AT-39-642E
AT-39-642U
AT-39-642L
AT-39-642
AT-39-742U
AT-39-742L
AT-39-742
AT-39-842
AT-39-942
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

748
664
754
840
799
884
927
1,011
839
945
1,042
1,130
986
1,084
1,174
1,197
1,239

(3) 3 FPT DRAIN

158-3/4"

14-7/8"

167-3/4

(3) 2 MPT MAKE-UP

2-1/2"

3/8"

42' 4-1/4"

Weights (LBS)
Shipping

Operating

17,910
16,680
16,770
17,010
19,260
19,350
17,130
17,190
18,000
18,240
18,360
18,420
19,590
19,710
19,770
18,480
19,830
450

31,440
30,210
30,300
30,540
32,790
32,880
30,660
30,720
31,530
31,770
31,890
31,950
33,120
33,240
33,300
32,010
33,360
450

Heaviest
SectionF

4,090
3,680
3,710
3,790
4,540
4,570
3,830
3,850
4,120
4,200
4,240
4,260
4,650
4,690
4,710
4,280
4,730
150

Fan
Motor (HP)

Air Flow
(CFM)

(3)7.5
(3)7.5
(3)10
(3)15
(3)7.5
(3)10
(3)20
(3)25
(3)10
(3)15
(3)20
(3)25
(3)15
(3)20
(3)25
(3)30
(3)30

165,200
167,700
183,700
209,300
162,400
177,900
229,300
246,200
180,800
205,600
224,900
241,300
202,400
221,400
237,400
255,700
251,200

Dimensions
H

13 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
14 6-3/4
14 6-3/4
12 6-3/4
12 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
13 6-3/4
14 6-3/4
1 9

8 1/2
7 1/2
7 1/2
7 1/2
9 1/2
9 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
1 9

9 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
10 9-1/2
10 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

66

Models: AT/UT/USS 310-136 to 310-936


Three-Cell Cooling Towers

ACCESS DOORS SWING


INSIDE UNIT
ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

7"

(3) 8 BFW/GROOVED
INLET

71-7/8

2"

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

H
P
86-1/4"

9" (3) 8 BFW/GROOVED


OUTLET

25-1/4"

5-1/4"

16-7/8"

(3) 3 FPT DRAIN

7-1/4"

(3) 2 MPT MAKE-UP

3-5/8"

71-7/8"
134-3/4"

9' 9-3/4"

Model No.

AT-310-136L
AT-310-136
AT-310-236E
AT-310-236U
AT-310-236L
AT-310-236
AT-310-336
AT-310-436
AT-310-536
AT-310-636E
AT-310-636U
AT-310-636L
AT-310-636
AT-310-736
AT-310-836
AT-310-936
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

782
914
672
817
903
963
1,000
1,012
1,068
821
953
1,038
1,106
1,126
1,164
1,216

143-3/4"

3/8"

5-1/4"

2-1/2"
36' 4-1/4"

Weights (LBS)
Shipping

Operating

21,030
21,030
19,380
19,590
19,740
19,890
21,180
20,190
21,330
22,080
22,290
22,440
22,590
21,630
22,890
23,640
2,100

37,650
37,650
36,000
36,210
36,360
36,510
37,800
36,810
37,950
38,700
38,910
39,060
39,210
38,250
39,510
40,260
2,100

Heaviest
SectionF

4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700

Fan
Motor (HP)

Air Flow
(CFM)

(3)10
(3)15
(3)10
(3)15
(3)20
(3)25
(3)20
(3)30
(3)25
(3)10
(3)15
(3)20
(3)25
(3)30
(3)30
(3)35

191,200
217,200
194,400
220,800
242,000
260,000
237,700
275,700
255,100
188,100
213,700
234,000
251,300
270,400
265,900
279,100

Dimensions
H

16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
1 9-1/2

9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2

11 1
11 1
10 1
10 1
10 1
10 1
11 1
10 1
11 1
12 1
12 1
12 1
12 1
11 1
12 1
12 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

67

(3) 3 FPT OVERFLOW

F Heaviest section is upper section.

Models: AT/UT/USS 310-154 to 310-954


Three-Cell Cooling Towers

ACCESS DOORS SWING


INSIDE UNIT

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

7"

ACCESS
DOOR

2"
T

(3) 10 BFW/GROOVED
INLET

108"

H
P
86-1/4"

(3) 10 BFW/GROOVED
OUTLET

25-1/4"

108"

(3) 3 FPT OVERFLOW

8-1/2"

Model No.

AT-310-154U
AT-310-154L
AT-310-154
AT-310-254L
AT-310-254
AT-310-354U
AT-310-354L
AT-310-354
AT-310-454L
AT-310-454
AT-310-554
AT-310-654
AT-310-754U
AT-310-754L
AT-310-754
AT-310-854
AT-310-954
UT Addition
NOTE:


(1)
(2)
(3)
(4)

(3) 2 MPT MAKE-UP

5-1/4"

3-5/8"
9' 9-3/4"

(3) 3 FPT DRAIN

207"

16-7/8"

216"

2-1/2"

3/8"

Nominal
Tonnage

859
1,040
1,154
1,080
1,247
988
1,173
1,296
1,246
1,320
1,398
1,481
1,369
1,467
1,552
1,624
1,694

54' 5"

Weights (LBS)
Shipping

Operating

26,910
27,120
27,270
31,080
31,080
28,980
29,190
29,340
27,420
27,720
29,490
29,790
31,230
31,380
31,680
30,540
32,430
2,100

52,130
52,340
52,490
56,300
56,300
54,200
54,410
54,560
52,640
52,940
54,710
55,010
56,450
56,600
56,900
55,760
57,650
2,100

Heaviest
SectionF

5,640
5,710
5,760
7,030
7,030
6,330
6,400
6,450
5,810
5,910
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700

Fan
Motor (HP)

Air Flow
(CFM)

(3)10
(3)15
(3)20
(3)10
(3)15
(3)10
(3)15
(3)20
(3)25
(3)30
(3)25
(3)30
(3)20
(3)25
(3)30
(3)40
(3)40

258,300
293,700
322,300
250,100
284,600
254,400
289,300
317,000
345,700
366,800
340,100
360,000
311,600
334,400
354,300
394,100
387,800

Dimensions
H

15 5-1/4
15 5-1/4
15 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
17 5-1/4
1 9-1/2

8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2

10 0
10 0
10 0
12 0
12 0
11 0
11 0
11 0
10 0
10 0
11 0
11 0
12 0
12 0
12 0
11 0
12 0

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

68

Models: AT/UT/USS 312-036 to 312-936


Three-Cell Cooling Towers

ACCESS DOOR

ACCESS DOOR

ACCESS DOORS SWING


INSIDE UNIT
ACCESS DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

T
2"

71-7/8"

ACCESS
DOOR

(3) 8 BFW/GROOVED
INLET

H
P
86-1/4"

(3) 8 BFW/GROOVED
9"
OUTLET
5-1/4"

25-1/4"
16-7/8"
7-1/4"
3-5/8"

71-7/8"
5-1/4"

143-3/4"

Model No.

AT-312-036U
AT 312-036L
AT 312-036
AT 312-136L
AT 312-136
AT 312-236
AT-312-236M
AT 312-336
AT-312-436U
AT 312-436L
AT 312-436
AT 312-536
AT 312-636
AT 312-736
AT 312-836
AT 312-936
UT Addition
NOTE:


(1)
(2)
(3)
(4)

36' 4-1/4"

851
1,014
1,106
960
1,122
1,187
1,257
1,224
1,021
1,174
1,277
1,316
1,375
1,398
1,458
1,560

Weights (LBS)
Shipping

Operating

21,900
22,110
22,260
23,520
23,730
22,410
22,710
23,880
24,990
25,200
25,350
24,030
25,500
24,330
25,800
26,550
2,100

40,530
40,740
40,890
42,150
42,360
41,040
41,340
42,510
43,620
43,830
43,980
42,660
44,130
42,960
44,430
45,180
2,100

Heaviest
SectionF

4,930
5,000
5,050
5,470
5,540
5,100
5,200
5,590
5,960
6,030
6,080
5,640
6,130
5,740
6,230
6,480
700

Fan
Motor (HP)

Air Flow
(CFM)

(3)10
(3)15
(3)20
(3)10
(3)15
(3)25
(3)30
(3)20
(3)10
(3)15
(3)20
(3)25
(3)25
(3)30
(3)30
(3)40

216,800
246,400
270,400
213,500
242,600
290,000
307,200
265,500
209,900
238,500
261,400
284,700
280,100
301,300
296,400
324,500

Dimensions
H

15 6-1/4
15 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
15 6-1/4
15 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
1 9-1/2

8 4
8 4
8 4
9 4
9 4
8 4
8 4
9 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
10 4
1 9-1/2

10 2
10 2
10 2
11 2
11 2
10 2
10 2
11 2
12 2
12 2
12 2
11 2
12 2
11 2
12 2
12 2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

69

2-1/2"

3/8"

Nominal
Tonnage

(3) 3 FPT DRAIN


(3) 2 MPT MAKE-UP

134-3/4"

11' 10"

(3) 3 FPT OVERFLOW

F Heaviest section is upper section.

Models: AT/UT/USS 312-042 to 312-942


Three-Cell Cooling Towers

ACCESS DOOR

ACCESS DOOR

ACCESS DOORS SWING


INSIDE UNIT
ACCESS DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

T
2"

83-7/8"

ACCESS
DOOR

(3) 10 BFW/GROOVED
INLET

H
P
98-1/4"

(3) 10 BFW/GROOVED
9
OUTLET
5-1/4"

25-1/4"
16-7/8"
8-1/2"
3-5/8"

(3) 2 MPT MAKE-UP

83-7/8"
158-3/4"

5-1/4"

167-3/4"
11' 10"

Model No.

AT-312-042L
AT-312-042
AT-312-142E
AT-312-142U
AT-312-142L
AT-312-142
AT-312-142M
AT-312-242L
AT-312-242
AT-312-342
AT-312-442
AT-312-542L
AT-312-542
AT-312-642
AT-312-742
AT-312-842
AT-312-942
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,045
1,229
910
1,091
1,195
1,289
1,366
1,123
1,293
1,330
1,428
1,395
1,495
1,519
1,589
1,662
1,738

(3) 3 FPT OVERFLOW


(3) 3 FPT DRAIN

2-1/2"
42' 4-1/4"

3/8"

Weights (LBS)
Shipping

Operating

26,580
26,790
24,600
24,810
24,990
25,170
25,380
28,140
28,350
26,970
27,150
28,530
28,710
27,360
28,920
28,140
29,700
2,100

48,570
48,780
46,590
46,800
46,980
47,160
47,370
50,130
50,340
48,960
49,140
50,520
50,700
49,350
50,910
50,130
51,690
2,100

Heaviest
SectionF

6,020
6,090
5,360
5,430
5,490
5,550
5,620
6,540
6,610
6,150
6,210
6,670
6,730
6,280
6,800
6,540
7,060
700

Fan
Motor (HP)

Air Flow
(CFM)

(3)10
(3)15
(3)10
(3)15
(3)20
(3)25
(3)30
(3)10
(3)15
(3)20
(3)25
(3)20
(3)25
(3)30
(3)30
(3)40
(3)40

231,900
263,400
235,500
267,800
293,600
315,200
334,000
227,900
259,100
288,500
309,500
284,000
304,600
327,600
322,400
359,100
352,800

Dimensions
H

17 6-1/4
17 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
1 9-1/2

9 4
9 4
8 4
8 4
8 4
8 4
8 4
10 4
10 4
9 4
9 4
10 4
10 4
9 4
10 4
9 4
10 4
1 9-1/2

12 1
12 1
11 1
11 1
11 1
11 1
11 1
13 1
13 1
12 1
12 1
13 1
13 1
12 1
13 1
12 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

70

Models: AT/UT/USS 312-054 to 312-954


Three-Cell Cooling Towers

ACCESS DOOR

ACCESS DOOR

ACCESS DOORS SWING


INSIDE UNIT
ACCESS DOOR

7"

ACCESS
DOOR

T
2"

ACCESS
DOOR

108"

ACCESS
DOOR

(3) 10 BFW/GROOVED
INLET

H
P
98-1/4"

(3) 10 BFW/GROOVED
OUTLET
5-1/4"

25-1/4"

9"

16-7/8"
8-1/2"
3-5/8"

Model No.

108"

207"

5-1/4"

AT-312-054E
AT-312-054U
AT-312-054L
AT-312-054
AT-312-154U
AT-312-154L
AT-312-154
AT-312-254
AT-312-354
AT-312-454E
AT-312-454U
AT-312-454L
AT-312-454
AT-312-554
AT-312-654
AT-312-754
AT-312-854
AT-312-954
UT Addition
NOTE:


(1)
(2)
(3)
(4)

54' 5"

1,324
1,499
1,586
1,670
1,473
1,648
1,752
1,840
1,851
1,560
1,725
1,828
1,935
2,036
2,124
2,182
2,281
2,367

Weights (LBS)
Shipping

Operating

31,620
31,800
31,950
32,280
33,960
34,140
34,290
33,060
34,620
36,180
36,360
36,510
36,840
35,400
37,620
35,580
37,800
38,130
3,600

59,430
59,610
59,760
60,090
61,770
61,950
62,100
60,870
62,430
63,990
64,170
64,320
64,650
63,210
65,430
63,390
65,610
65,940
3,600

Heaviest
SectionF

6,700
6,760
6,810
6,920
7,480
7,540
7,590
7,180
7,700
8,220
8,280
8,330
8,440
7,960
8,700
8,020
8,760
8,870
1,200

Fan
Motor (HP)

Air Flow
(CFM)

(3)15
(3)20
(3)25
(3)30
(3)15
(3)20
(3)25
(3)40
(3)30
(3)15
(3)20
(3)25
(3)30
(3)40
(3)40
(3)50
(3)50
(3)60

330,500
362,000
389,000
412,300
325,600
356,200
382,300
451,700
405,300
320,200
350,500
376,300
398,900
443,500
436,200
475,900
467,400
495,100

Dimensions
H

16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2

8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
10 4
1 3-1/2

11 1
11 1
11 1
11 1
12 1
12 1
12 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
13 1
12 1
13 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

71

2-1/2"

3/8"

Nominal
Tonnage

(3) 3 FPT DRAIN


(3) 2 MPT MAKE-UP

216"
11' 10"

(3) 3 FPT OVERFLOW

F Heaviest section is upper section.

Models: AT/UT/USS 312-260 to 312-960


Three-Cell Cooling Towers

ACCESS DOORS SWING


INSIDE UNIT

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

7"

ACCESS
DOOR

T
2"

ACCESS
DOOR

ACCESS
DOOR

(3) 10 BFW/GROOVED
INLET

120"
H
P
98-1/4"

(3) 10 BFW/GROOVED
OUTLET

25-1/4"

120"

(3) 3 FPT OVERFLOW

231"

16-7/8"
8-1/2"

5-1/4"

3-5/8"
11' 10"

Model No.

AT-312-160
AT-312-260L
AT-312-260
AT-312-360L
AT-312-360
AT-312-460E
AT-312-460U
AT-312-460L
AT-312-460
AT-312-560L
AT-312-560
AT-312-660L
AT-312-660
AT-312-760
AT-312-860
AT-312-960
UT Addition
NOTE:


(1)
(2)
(3)
(4)

(3) 3 FPT DRAIN

240"

(3) 2 MPT MAKE-UP

2-1/2"

3/8"

Nominal
Tonnage

1,368
1,600
1,745
1,707
1,844
1,508
1,622
1,865
2,023
1,859
2,083
1,955
2,174
2,260
2,352
2,440

60' 5"

Weights (LBS)
Shipping

Operating

33,960
36,150
36,300
38,850
39,000
34,110
34,440
35,220
35,400
36,630
37,410
39,330
40,110
37,590
40,290
40,620
3,600

65,160
67,350
67,500
70,050
70,200
65,310
65,640
66,420
66,600
67,830
68,610
70,530
71,310
68,790
71,490
71,820
3,600

Heaviest
SectionF

7,210
7,940
7,990
8,840
8,890
7,260
7,370
7,630
7,690
8,100
8,360
9,000
9,260
8,420
9,320
9,430
1,200

Fan
Motor (HP)

Air Flow
(CFM)

(3)20
(3)20
(3)25
(3)20
(3)25
(3)25
(3)30
(3)40
(3)50
(3)30
(3)40
(3)30
(3)40
(3)50
(3)50
(3)60

369,800
363,700
390,100
357,600
383,700
396,900
420,600
460,000
493,600
413,000
451,400
406,400
444,400
484,000
476,100
504,600

Dimensions
H

16 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2

8 4
9 4
9 4
10 4
10 4
8 4
8 4
8 4
8 4
9 4
9 4
10 4
10 4
9 4
10 4
10 4
1 3-1/2

11 1
12 1
12 1
13 1
13 1
11 1
11 1
11 1
11 1
12 1
12 1
13 1
13 1
12 1
13 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.

72

Models: AT/UT/USS 314-0172 to 314-1272


Three-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

7"

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR
(3) 14 BFW/GROOVED
INLET

142-1/2"

2"
H
P
99-3/8"

(3) 14 BFW/GROOVED
OUTLET

26"
142-1/2"

Model No.

AT-314-0172U
AT-314-0172L
AT-314-0172
AT-314-0272
AT-314-0372
AT-314-0472L
AT-314-0472
AT-314-0572
AT-314-0672E
AT-314-0672U
AT-314-0672L
AT-314-0672
AT-314-0772
AT-314-0872
AT-314-0972
AT-314-1072
AT-314-1172
AT-314-1272
UT Addition
NOTE:


(1)
(2)
(3)
(4)

3/8"

Nominal
Tonnage

1,789
1,986
2,095
2,271
2,439
2,255
2,437
2,551
2,056
2,257
2,364
2,601
2,773
2,770
2,919
2,944
3,091
3,322

285"

4-1/8"

(3) 4 FPT
DRAIN

2-1/2"
71' 8"

Weights (LBS)
Shipping

Operating

53,340
53,490
53,550
54,000
55,050
59,580
59,730
59,790
56,460
56,610
56,670
57,120
58,170
60,240
61,290
58,680
61,800
62,520
3,750

100,890
101,040
101,100
101,550
102,600
107,130
107,280
107,340
104,010
104,160
104,220
104,670
105,720
107,790
108,840
106,230
109,350
110,070
3,750

Heaviest
SectionF

10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,210
12,900
13,250
12,380
13,420
13,660
1,250

Fan
Motor (HP)

Air Flow
(CFM)

(3)20
(3)25
(3)30
(3)40
(3)50
(3)20
(3)25
(3)30
(3)20
(3)25
(3)30
(3)40
(3)50
(3)40
(3)50
(3)60
(3)60
(3)75

467,000
499,900
530,100
580,900
624,200
447,100
479,800
509,800
460,000
493,500
521,300
570,700
613,000
561,200
602,700
648,600
638,300
699,700

Dimensions
H

17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2

9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2

11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

73

(3) 4 FPT
OVERFLOW

276"

9"
13' 11-1/4"

9"
72-1/4"

212-3/4"

17-3/8"

(3) 3 MPT
MAKE-UP

F Heaviest section is upper section.

Models: AT/UT/USS 314-578 to 314-978


Three-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

7"

ACCESS
DOOR

2"

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

T
(3) 14 BFW/GROOVED
INLET

154-1/2"
H
P
123-3/8"

26"
154-1/2"

17-3/8"

230-5/8"

9"
4-1/8"

Model No.

AT-314-578
AT-314-678
AT-314-778
AT-314-878
AT-314-978
UT Addition
NOTE:


(1)
(2)
(3)
(4)

(3) 3 MPT MAKE-UP

(3) 4 FPT DRAIN

299-7/8"
308-7/8"

13' 11-1/4"

(3) 14 BFW/GROOVED
OUTLET

(3) 4 FPT
OVERFLOW

2-1/2"

3/8"

77' 7-5/8"

Nominal
Tonnage

2,936
3,157
3,344
3,655
3,908

Weights (LBS)
Shipping

Operating

73,620
73,800
74,100
75,060
75,120
D

124,110
124,290
124,590
125,550
125,610
7,200

Heaviest
SectionF

17,660
17,720
17,820
18,140
18,160
D

Fan
Motor (HP)

Air Flow
(CFM)

(6)20
(6)25
(6)30
(6)40
(6)50

586,300
628,800
665,700
728,100
780,300

Dimensions
H

22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2

12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2

16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

74

Models: AT/UT/USS 342-526 to 342-926


Three-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


(2) ACCESS DOOR

(2) ACCESS DOOR

(2) ACCESS DOOR

(3) 14 BFW/GVD EQUALIZER


(3) 14 BFW/GVD OUTLET
(3) 14 BFW/GVD INLET

173-1/2" 154-1/2"
135-1/2"

83-5/8"
143"
256"
315-3/8"
428-3/8"
487-3/4"
42' 8"
7"

(2) ACCESS
DOOR

(2) ACCESS
DOOR

(2) ACCESS
DOOR

123-3/8"
26"
17-3/8"
4"
25' 8-7/8"

157-1/4"

(3) 3 MPT MAKE-UP

161-1/2"

(3) 4 MPT OVERFLOW

162-1/2"

(3) 4 MPT DRAIN

167-1/4"

1- 3/8"

5-1/8"
42' 8"

Model No.

AT-342-526
AT-342-626
AT-342-726
AT-342-826
AT-342-926
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal Tonnage

2,882
3,100
3,286
3,593
3,844

Weights (LBS)
Shipping

Operating

73,410
73,590
73,890
74,850
74,910
D

123,900
124,080
124,380
125,340
125,400
7,200

17,660
17,720
17,820
18,140
18,160
D

Fan
Air Flow (CFM)
Motor (HP)

(6)20
(6)25
(6)30
(6)40
(6)50

560,606
601,334
636,679
696,431
746,358

Dimensions
H

22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2

12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

75

Heaviest
SectionF

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

Models: AT/UT/USS 420-124 to 420-924


Four-Cell Cooling Towers
ACCESS DOORS SWING INSIDE UNIT
ACCESS DOOR

7"

ACCESS
DOOR

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

2"

58-7/8"

(4) 8 BFW/GROOVED
INLET

ACCESS DOOR

ACCESS DOOR

2"

P
98-1/4"

(2) 12 BFW/GROOVED
OUTLET

(2) 3 MPT
OVERFLOW

25-1/4"

(2) 2 MPT
MAKE-UP

93-5/8"

(2) 3 MPT
DRAIN

16-7/8"

108-3/4"

9-1/2"

112-1/2"

3-5/8"

113-1/2"
117-3/4"

5-1/8
20' 5/8"

Model No.

AT-420-124L
AT-420-124
AT-420-224E
AT-420-224U
AT-420-224L
AT-420-224
AT-420-324
AT-420-424
AT-420-524
AT-420-624E
AT-420-624U
AT-420-624L
AT-420-624
AT-420-724
AT-420-824
AT-420-924
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,051
1,229
904
1,098
1,214
1,295
1,344
1,361
1,435
1,103
1,281
1,394
1,485
1,513
1,563
1,632

1-3/8"

Weights (LBS)
Shipping

Operating

27,420
27,700
25,500
25,780
25,980
26,180
27,900
26,580
28,100
29,100
29,380
29,580
29,780
28,500
30,180
31,180
D

49,560
49,840
47,640
47,920
48,120
48,320
50,040
48,720
50,240
51,240
51,520
51,720
51,920
50,640
52,320
53,320
2,800

Heaviest
SectionF

U 4,680
U 4,750
L 4,350
L 4,350
L 4,350
U 4,370
U 4,800
U 4,470
U 4,850
U 5,100
U 5,170
U 5,250
U 5,270
U 4,950
U 5,370
U 5,620
D

24' 1-3/4"

Fan
Air Flow (CFM)
Motor (HP)

(4)10
(4)15
(4)10
(4)15
(4)20
(4)25
(4)20
(4)30
(4)25
(4)10
(4)15
(4)20
(4)25
(4)30
(4)30
(4)35

252,300
286,500
256,500
291,400
319,200
343,000
313,600
363,600
336,500
248,200
281,900
308,700
331,400
356,600
350,900
368,000

Dimensions
H

17 5 1/4
17 5 1/4
16 5 1/4
16 5 1/4
16 5 1/4
16 5 1/4
17 5 1/4
16 5 1/4
17 5 1/4
18 5 1/4
18 5 1/4
18 5 1/4
18 5 1/4
17 5 1/4
18 5 1/4
18 5 1/4
1 9-1/2

9 3
9 3
9 3
9 3
9 3
9 3
8 3
9 3
8 3
10 3
10 3
10 3
10 3
8 3
10 3
10 3
1 9-1/2

12 1
12 1
11 1
11 1
11 1
11 1
12 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
13 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F L=Lower Section, U=Upper Section


D Please consult the factory for additional information regarding shipping and section weight changes.

76

Models: AT/UT/USS 420-136 to 420-936


Four-Cell Cooling Towers
ACCESS DOORS SWING INSIDE UNIT
ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

7"

(4) 10 BFW/GROOVED
INLET

58-7/8"

(4) 10 BFW/GROOVED
OUTLET

5-1/8"

117-3/4"

98-1/4"

8-1/2"
3-5/8"

AT-420-136U
AT-420-136L
AT-420-136
AT-420-236L
AT-420-236
AT-420-336U
AT-420-336L
AT-420-336
AT-420-436L
AT-420-436
AT-420-536
AT-420-636
AT-420-736U
AT-420-736L
AT-420-736
AT-420-836
AT-420-936
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,111
1,348
1,496
1,408
1,626
1,281
1,522
1,686
1,618
1,713
1,820
1,928
1,786
1,914
2,025
2,116
2,212

Weights (LBS)
Shipping

Operating

35,300
35,580
35,780
40,860
40,860
38,060
38,340
38,540
35,980
36,380
38,740
39,140
41,060
41,260
41,660
40,140
42,660
D

69,260
69,540
69,740
74,820
74,820
72,020
72,300
72,500
69,940
70,340
72,700
73,100
75,020
75,220
75,620
74,100
76,620
2,800

Heaviest
SectionF

L6,370
L 6,370
L 6,370
U 7,030
U 7,030
L 6,370
U 6,400
U 6,450
L 6,370
L 6,370
U 6,500
U 6,600
U 7,080
U 7,130
U 7,230
U 6,850
U 7,480
D

Fan
Air Flow (CFM)
Motor (HP)

(4)10
(4)15
(4)20
(4)10
(4)15
(4)10
(4)15
(4)20
(4)25
(4)30
(4)25
(4)30
(4)20
(4)25
(4)30
(4)40
(4)40

330,400
375,800
412,300
319,900
364,200
325,400
370,200
405,800
442,400
469,300
435,200
460,900
398,700
427,900
453,400
504,500
496,200

1-3/8"

Dimensions
H

16 5-1/4
16 5-1/4
16 5-1/4
18 5-1/4
18 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
18 5-1/4
18 5-1/4
18 5-1/4
17 5-1/4
18 5-1/4
1 9-1/2

9 3
9 3
9 3
10 3
10 3
8 3
8 3
8 3
9 3
9 3
8 3
8 3
10 3
10 3
10 3
8 3
10 3
1 9-1/2

11
11
11
13
13
12
12
12
11
11
12
12
13
13
13
12
13

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

77

36' 2-1/2"

1-3/8"

20' 5/8"

Model No.

2"

16-7/8"

112-1/2"
113-1/2"

ACCESS
DOOR

25-1/4"

93-5/8"
108-3/4"

(4) 3 MPT
DRAIN

ACCESS
DOOR

ACCESS
DOOR

2"

(4) 2 MPT
MAKE-UP
(4) 3 MPT
OVERFLOW

ACCESS
DOOR

F L=Lower Section, U=Upper Section


D Please consult the factory for additional information regarding shipping and section weight changes.

Models: AT/UT/USS 424-024 to 424-924


Four-Cell Cooling Towers

ACCESS
DOOR

ACCESS
DOOR

ACCESS DOORS SWING INSIDE UNIT

ACCESS
DOOR

ACCESS
DOOR

(4) 8 BFW/GROOVED
OUTLET

71"

7"
P

ACCESS
DOOR

(2) 12 BFW/GROOVED
OUTLET

(2) 3 MPT OVERFLOW


(2) 2 MPT MAKE-UP

9-1/2"

133"

ACCESS
DOOR

3-5/8"

136-3/4"

(2) 3 MPT DRAIN

ACCESS
DOOR

2"

25-1/4"
16-7/8"

117-7/8"

ACCESS
DOOR

137-3/4"
5-1/8"

142"

98-1/4"

24' 1-1/8"

1-3/8"

Model No.

AT-424-024L
AT-424-024
AT-424-124
AT-424-224L
AT-424-224
AT-424-324
AT-424-424
AT-424-524
AT-424-624U
AT-424-624L
AT-424-624
AT-424-724
AT-424-824
AT-424-924U
AT-424-924L
AT-424-924
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,114
1,327
1,449
1,257
1,471
1,555
1,605
1,647
1,340
1,524
1,678
1,727
1,835
1,807
1,916
2,050

Weights (LBS)
Shipping

Operating

29,480
30,040
30,240
31,640
32,200
30,440
32,400
30,840
33,600
34,160
34,360
32,600
33,000
34,560
34,960
35,960
D

54,340
54,900
55,100
56,500
57,060
55,300
57,260
55,700
58,460
59,020
59,220
57,460
57,860
59,420
59,820
60,820
4,800

Heaviest
SectionF

L 5,020
L 5,020
U 5,050
U 5,400
U 5,540
U 5,100
U 5,590
U 5,200
U 5,890
U 6,030
U 6,080
U 5,640
U 5,740
U 6,130
U 6,230
U 6,480
D

24' 1-3/4"

Fan
Air Flow (CFM)
Motor (HP)

(4)10
(4)15
(4)20
(4)10
(4)15
(4)25
(4)20
(4)30
(4)10
(4)15
(4)20
(4)25
(4)30
(4)25
(4)30
(4)40

283,500
322,300
353,400
279,200
317,000
379,400
347,400
401,900
274,500
312,000
341,900
372,500
394,400
366,200
387,500
424,600

Dimensions
H

16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 9-1/2

8 4
8 4
8 4
9 4
9 4
8 4
9 4
8 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 9-1/2

11 2
11 2
11 2
12 2
12 2
11 2
12 2
11 2
13 2
13 2
12 2
12 2
13 2
13 2
13 2
13 2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F L=Lower Section, U=Upper Section


D Please consult the factory for additional information regarding shipping and section weight changes.

78

Models: AT/UT/USS 424-028 to 424-928


Four-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS
DOOR

ACCESS
DOOR

71"

(4) 10 BFW/GROOVED
OUTLET

7"

(4) 10 BFW/GROOVED
OUTLET

(4) 3 MPT OVERFLOW

117-7/8"

(4) 2 MPT MAKE-UP

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

3-5/8"

136-3/4"

2"

137-3/4"
5-1/8"

ACCESS
DOOR

25-1/4"
16-7/8"
8-1/2"

133"

(4) 3 MPT DRAIN

ACCESS
DOOR

142"

24' 1-1/8"

98-1/4"

1- 3/8"

Model No.

AT-424-028U
AT-424-028L
AT-424-028
AT-424-128L
AT-424-128
AT-424-228
AT-424-228M
AT-424-328U
AT-424-328L
AT-424-328
AT-424-428
AT-424-528
AT-424-628
AT-424-728
AT-424-728M
AT-424-828
AT-424-928
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,159
1,405
1,564
1,434
1,654
1,689
1,838
1,322
1,563
1,745
1,833
1,873
1,965
1,993
2,199
2,088
2,283

Weights (LBS)
Shipping

Operating

32,680
33,240
33,480
37,400
37,960
33,720
34,000
35,320
35,880
36,120
38,200
36,360
38,440
36,640
37,680
38,720
39,760
D

62,140
62,700
62,940
66,860
67,420
63,180
63,460
64,780
65,340
65,580
67,660
65,820
67,900
66,100
67,140
68,180
69,220
4,800

L 5,760
L 5,760
L 5,760
U 6,470
U 6,610
L 5,760
L 5,760
U 5,950
U 6,090
U 6,150
U 6,670
U 6,210
U 6,730
U 6,280
U 6,540
U 6,800
U 7,060
D

Fan
Air Flow (CFM)
Motor (HP)

(4)10
(4)15
(4)20
(4)10
(4)15
(4)25
(4)30
(4)10
(4)15
(4)20
(4)20
(4)25
(4)25
(4)30
(4)40
(4)30
(4)40

299,400
340,300
372,900
289,800
329,600
400,300
423,700
294,900
335,100
366,600
360,700
393,600
387,300
416,200
455,600
409,900
448,300

Dimensions
H

16 6-1/4
16 6-1/4
16 6-1/4
18 6-1/4
18 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
1 9-1/2

8 4
8 4
8 4
10 4
10 4
8 4
8 4
9 4
9 4
9 4
10 4
9 4
10 4
9 4
9 4
10 4
10 4
1 9-1/2

11 1
11 1
11 1
13 1
13 1
11 1
11 1
12 1
12 1
12 1
13 1
12 1
13 1
12 1
13 1
13 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

79

Heaviest
SectionF

1- 3/8"

28' 1-3/4"

F L=Lower Section, U=Upper Section


D Please consult the factory for additional information regarding shipping and section weight changes.

Models: AT/UT/USS 424-036 to 424-936


Four-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


ACCESS
DOOR

ACCESS
DOOR

71"

(4) 10 BFW/GROOVED
INLET

P
7"

(4) 10 BFW/GROOVED
OUTLET

(4) 3 MPT OVERFLOW

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

2"

3-5/8"

136-3/4"

137-3/4"
5-1/8"

ACCESS DOOR

8-1/2"

133"

(4) 3 MPT DRAIN

ACCESS
DOOR

25-1/4"
16-7/8"

117-7/8"

(4) 2 MPT MAKE-UP

ACCESS DOOR

142"

24' 1-1/8"
98-1/4"

1- 3/8"

Model No.

AT-424-036L
AT-424-036
AT-424-136
AT-424-236U
AT-424-236L
AT-424-236
AT-424-336L
AT-424-336
AT-424-436
AT-424-536E
AT-424-536U
AT-424-536L
AT-424-536
AT-424-636
AT-424-736
AT-424-836L
AT-424-836
AT-424-936
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,687
1,914
2,023
1,883
2,108
2,246
2,133
2,350
2,373
2,005
2,221
2,353
2,491
2,614
2,806
2,736
2,938
3,049

Weights (LBS)
Shipping

Operating

41,760
42,000
42,200
44,880
45,120
45,320
42,640
43,680
45,760
47,840
48,080
48,280
48,720
46,800
46,800
49,760
50,000
50,440
D

79,040
79,280
79,480
82,160
82,400
82,600
79,920
80,960
83,040
85,120
85,360
85,560
86,000
84,080
84,320
87,040
87,280
87,720
4,800

Heaviest
SectionF

L 7,480
L 7,480
L 7,480
U 7,480
U 7,540
U 7,590
L 7,480
L 7,480
U 7,700
U 8,220
U 8,280
U 8,330
U 8,440
U 7,960
U 8,020
U 8,700
U 8,760
U 8,870
D

1- 3/8"

36' 2-1/4"

Fan
Air Flow (CFM)
Motor (HP)

(4)15
(4)20
(4)25
(4)15
(4)20
(4)25
(4)30
(4)40
(4)30
(4)15
(4)20
(4)25
(4)30
(4)40
(4)50
(4)40
(4)50
(4)60

423,100
463,300
498,000
416,900
456,200
489,600
527,900
578,400
519,200
409,800
448,800
481,900
510,800
567,900
609,200
558,300
598,800
634,500

Dimensions
H

16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2

8 4
8 4
8 4
9 4
9 4
9 4
8 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 3-1/2

11 1
11 1
11 1
12 1
12 1
12 1
11 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
12 1
13 1
13 1
13 1

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F L=Lower Section, U=Upper Section


D Please consult the factory for additional information regarding shipping and section weight changes.

80

Models: AT/UT/USS 424-0140 to 424-1640


Four-Cell Cooling Towers
ACCESS DOORS SWING INSIDE UNIT
ACCESS DOOR

ACCESS DOOR

AC CE SS DO O R

ACC ES S DO OR

7"

2"
T

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

71"

(4) 10 BFW/GROOVED
INLET

H
P
98-1/4"

(4) 12 BFW/GROOVED
OUTLET

(4) 3 FPT OVERFLOW

25-1/4"

117-7/8"

(4) 2 MPT MAKE-UP

133"

9-1/2"

136-3/4"

(4) 3 FPT DRAIN

16-7/8"

3-5/8"

137-3/4"
5-1/8"

142"

1-3/8"

24'-1-1/8"

Model No.

AT-424-0140
AT-424-0240
AT-424-0340
AT-424-0440
AT-424-0540
AT-424-0640
AT-424-0740
AT-424-0840
AT-424-0940
AT-424-1040
AT-424-1140
AT-424-1240
AT-424-1340
AT-424-1440
AT-424-1540
AT-424-1640
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

1,733
1,919
2,064
2,379
2,584
2,038
2,230
2,380
2,670
2,900
2,190
2,369
2,515
2,798
3,028
3,141

Weights (LBS)
Shipping

Operating

44,640
44,840
45,280
46,320
46,560
47,560
47,760
48,200
49,240
49,480
51,160
51,360
51,800
52,840
53,080
53,520
D

86,420
86,620
87,060
88,100
88,340
89,340
89,540
89,980
91,020
91,260
92,940
93,140
93,580
94,620
94,860
95,300
4,800

L 7,900
L 7,900
L 7,900
L 7,900
L 7,900
U 7,940
U 7,990
U 8,100
U 8,360
U 8,420
U 8,840
U 8,890
U 9,000
U 9,260
U 9,320
U 9,430
D

Fan
Air Flow (CFM)
Motor (HP)

(4)20
(4)25
(4)30
(4)40
(4)50
(4)20
(4)25
(4)30
(4)40
(4)50
(4)20
(4)25
(4)30
(4)40
(4)50
(4)60

472,200
506,800
537,000
587,500
630,400
464,500
498,300
527,600
576,800
618,200
456,500
489,900
519,000
567,600
608,300
644,800

1-3/8"

Dimensions
H

16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2

8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
10 4
10 4

11 1
11 1
11 1
11 1
11 1
12 1
12 1
12 1
12 1
12 1
13 11
13 11
13 11
13 11
13 11
13 11

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

81

Heaviest
SectionF

40'-2-1/4"

F L=Lower Section, U=Upper Section


D Please consult the factory for additional information regarding shipping and section weight changes.

Models: AT/UT/USS 428-0148 to 428-1348


Four-Cell Cooling Towers

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

7"

ACCESS DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

ACCESS
DOOR

(4) 14 BFW/GROOVED
INLET

142-1/2"

2"

ACCESS DOORS SWING INSIDE UNIT

H
P
99-3/8"
26"
(4) 14 BFW/GOOVED
OUTLET

(4) 4 MPT OVERFLOW


(4) 3 MPT MAKE-UP

(4) 12 BFW/GOOVED EQUALIZER


IN-LINE WITH OUTLETS
17-3/8"

138"
157-3/8"

(4) 4 MPT DRAIN

9"
4-1/8"

161-5/8"
162-1/8"

5-1/8"

285"

AT-428-0148U
AT-428-0148L
AT-428-0148
AT-428-0248
AT-428-0348
AT-428-0448L
AT-428-0448
AT-428-0548
AT-428-0648E
AT-428-0648U
AT-428-0648L
AT-428-0648
AT-428-0748
AT-428-0848
AT-428-0948
AT-428-1048
AT-428-1148
AT-428-1248
AT-428-1348*
UT Addition
NOTE:


(1)
(2)
(3)
(4)

51' 1"

1- 3/8"

28' 3-5/8"

Model No.

43"

167-1/4"

Weights (LBS)

Nominal
Tonnage

Shipping

Operating

2,231
2,482
2,626
2,846
3,067
2,858
3,093
3,237
2,585
2,837
2,984
3,283
3,509
3,524
3,714
3,728
3,933
4,229
4,475

65,280
65,480
65,560
66,160
67,560
73,600
73,800
73,880
69,440
69,640
69,720
70,320
71,720
74,480
75,880
72,400
76,560
77,520
79,820

128,680
128,880
128,960
129,560
130,960
137,000
137,200
137,280
132,840
133,040
133,120
133,720
135,120
137,880
139,280
135,800
139,960
140,920
142,680
5,000

Heaviest
SectionF

10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,210
12,900
13,250
12,380
13,420
13,660
14,100
1,250

Fan
Air Flow (CFM)
Motor (HP)

(4)20
(4)25
(4)30
(4)40
(4)50
(4)20
(4)25
(4)30
(4)20
(4)25
(4)30
(4)40
(4)50
(4)40
(4)50
(4)60
(4)60
(4)75
(4)100

595,300
646,400
685,500
752,000
807,000
578,700
621,100
660,100
586,200
629,300
675,000
739,200
793,000
726,500
780,200
840,300
826,200
904,900
970,300

1- 3/8"

Dimensions
H

17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2

9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2

11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

82

Models: AT/UT/USS 428-552 to 428-952


Four-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT

7"

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS DOOR

ACCESS
DOORS

ACCESS
DOORS

ACCESS
DOORS

ACCESS
DOORS

T
(4) 14 BFW/GROOVED
INLET

2"

83-5/8"
H
P

123-3/8"

(2) 14 BFW/GROOVED
OUTLET

(4) 4 MPT OVERFLOW


(4) 3 MPT MAKE-UP
(4) 4 MPT DRAIN

5-1/8"

26"

17-3/8"

138"
157-1/4"
161-1/2"

AT-428-552
AT-428-652
AT-428-752
AT-428-852
AT-428-952
UT Addition
NOTE:


(1)
(2)
(3)
(4)

Nominal
Tonnage

3,857
4,148
4,395
4,806
5,141

(4) 12 BFW/GROOVED EQUALIZER


IN-LINE WITH OUTLETS

9"
4"

1-3/8"

Weights (LBS)
Shipping

Operating

97,960
98,200
98,600
99,880
99,960
D

165,280
165,520
165,920
167,200
167,280
9,600

Heaviest
SectionF

17,660
17,720
17,820
18,140
18,160
D

55' 3/4"

Fan
Air Flow (CFM)
Motor (HP)

(8)20
(8)25
(8)30
(8)40
(8)50

747,500
801,900
849,100
928,900
995,700

1-3/8"

Dimensions
H

22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2

12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2

16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

83

43"

162-1/2"
167-1/4"

28' 3-5/8"

Model No.

308-7/8"

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

Models: AT/UT/USS 456-526 to 456-926


Four-Cell Cooling Towers

ACCESS DOORS SWING INSIDE UNIT


(2) ACCESS DOOR

(2) ACCESS DOOR

(2) ACCESS DOOR

(2) ACCESS DOOR

(4) 14 BFW/GVD EQUALIZER


(4) 14 BFW/GVD OUTLET
(4) 14 BFW/GVD INLET

25'-8 7/8"
173-1/2" 154-1/2"
135-1/2"

83-5/8"

83-5/8"

143"

143"

196-5/8"

196-5/8"

256"

256"
57' 3/8"
7"

(2) ACCESS
DOOR

(2) ACCESS
DOOR

(2) ACCESS
DOOR

(2) ACCESS
DOOR

H
123-3/8"

26"
17-3/8"
4"

(4) 3 MPT MAKE-UP

161-1/2"

(4) 4 MPT OVERFLOW


(4) 4 MPT DRAIN

162-1/2"

1-3/8"

25' 8-7/8"

157-1/4"

167-1/4"

5-1/8"
57' 3/8"

Weights (LBS)

Model No.

Nominal
Tonnage

Shipping

Operating

Heaviest SectionF

AT-456-526
AT-456-626
AT-456-726
AT-456-826
AT-456-926

3,802
4,090
4,335
4,743
5,075

97,880
98,120
98,520
99,800
99,880

165,200
165,440
165,840
167,120
167,200

17,660
17,720
17,820
18,140
18,160

9,600

UT Addition
NOTE:


(1)
(2)
(3)
(4)

FanMotor (HP)

Air Flow (CFM)

(8)20
(8)25
(8)30
(8)40
(8)50

711,215
762,926
807,791
883,646
947,043

Dimensions
H

22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2

12 1/8
12 1/8
12 1/8
12 1/8
12 1/8

1 3-1/2

An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.

Outlet connection extends beyond bottom flange.


Height includes fan guard which ships factory mounted.

F Heaviest section is upper section.


D Please consult the factory for additional information regarding shipping and section weight changes.

84

Drain Down Volume for


Remote Sump Applications

14-64 to14-94
14-66 to 14-96
14-69 to 14-99
14-612 to 14-912

Maximum Drain Down


Volume (gal.)
85
130
195
275

19-56 to 19-96
19-28 to 19-98
19-59 to 19-99
19-111 to 19-911
19-412 to 19-912
19-114 to 19-914

270
320
395
460
525
610

110-112 to 110-912
110-118 to 110-918

645
980

112-012 to 112-912
112-314 to 112-914

720
855

112-018 to 112-918
112-520 to 112-920

1090
1210

114-0124 to114-1324
114-526 to 114-926

1855
2085

1-CELL

Model No.

85

2-CELL
3-CELL

The water volume provided is the cooling tower portion of


the remote sump tank only. The tank should allow for drain
down water from external piping and pump suction coverage.

26-517 to 26-917

Maximum Drain Down


Volume (gal.)
540

28-217 to 28-917

640

Model No.

4-CELL

The following chart provides the maximum drain down volume allowable per AT/UT/USS model number. Use this chart
when sizing indoor or outdoor remote sumps tanks. Remote
sump applications are commonly used whenever a cooling
tower is idle during sub-freezing weather to protect the water
in the basin from freezing or for large multi-tower industrial
applications. Either application allows the circulating water to
gravity drain into a remote sump tank indoors or a large, outdoor concrete basin located underneath the cooling tower.

212-59 to 212-99

540

215-29 to 215-99

640

217-59 to 217-99
217-111 to 217-911
217-412 to 217-912
217-214 to 217-914

790
920
1050
1220

29-318 to 29-918
29-121 to 29-921
29-024 to 29-924
29-228 to 29-928

790
920
1050
1220

210-124 to 210-924
210-136 to 210-936

1290
1960

212-024 to 212-924
212-128 to 212-928
212-036 to 212-936
212-0140 to 212-1640

1440
1710
2180
2420

214-0148 to214-1248
214-552 to 214-952

3710
4170

220-112 to 220-912
220-118 to 220-918

1290
1960

224-018 to 224-918
224-720 to 224-920

2180
2420

228-0124 to 228-1024
228-526 to 228-926

3710
4170

39-336 to 39-936
39-242 to 39-942

1575
1830

310-136 to 310-936
310-154 to 310-954

1935
2940

312-036 to 312-936
312-042 to 312-942
312-054 to 312-954
312-260 to 312-960

2160
2565
3270
3630

314-0172 to 314-1272
314-578 to 314-978
342-526 to 342-926

5565
6255
6255

420-124 to 420-924
420-136 to 420-936

2580
3920

424-024 to 424-924
424-028 to 424-928
424-036 to 424-936
424-0140 to 424-1640

2880
3420
4360
4840

428-0148 to 428-1348
428-552 to 428-952
456-526 to 456-926

7420
8340
8340

Applications
Design
EVAPCO Cooling towers are of heavy-duty construction and designed for
long trouble-free operation. Proper equipment selection, installation and
maintenance are necessary to ensure full unit performance while maximizing the equipments service life. Some of the major considerations in the
application of a tower are presented below. For additional information, please
contact the factory.
Piping
Cooling tower piping should be designed and installed in accordance with
generally accepted engineering practices. All piping should be anchored by
properly designed hangers and supports with allowance made for possible
expansion and contraction. No external loads should be placed upon cooling tower connections, nor should any of the piping supports be anchored to
the unit framework.
The piping connection locations shown on the drawings included in this
catalog and on the website are standard locations that can be changed. If
the piping connection locations shown do not meet the needs of a particular
project, contact the factory to determine a viable solution.
Air Circulation
In reviewing the system design and unit location, it is important that enough
fresh air is provided to enable proper unit performance. The best location
is on an unobstructed roof top or at ground level away from walls and other
barriers. Care must be taken when locating towers in wells or enclosures or
next to high walls. The potential for recirculation of the hot, moist discharge
air back into the fan intake exists. Recirculation raises the wetbulb temperature of the entering air, causing the leaving water temperature to rise above
the design conditions. For these cases, the overall unit height should be
raised so it is even with the adjacent wall, reducing the chance of recirculation. This can be done by raising the entire unit or adding a discharge hood.
For additional information, see the EVAPCO Equipment Layout Manual.
Engineering Assistance is also available from the factory to identify potential
recirculation problems and recommend solutions, such as re-orienting multicell units.
Design Flexibility and Assistance
The large number of EVAPCO AT Cooling towers makes it easy to find a
model to meet your design and layout needs. If there is an application for
which the standard catalog product line does not work, EVAPCO will make a
cooling tower that will fit your requirement. Consult your local EVAPCO Representative or the factory for assistance with Applications, Layout, Accessories
or other design needs.

Without proper water treatment, the equipment can be susceptible to scale


build-up on its heat exchange surfaces, biological growth in the recirculating
water and corrosion of its components. Your site specific water treatment
protocol should include procedures for routine operation, startup after a shutdown period, and system lay-up, if applicable.
Passivation Period
If the equipment includes any galvanized components, the initial commissioning and passivation period is a critical time for maximizing the service
life of galvanized equipment. Evapco recommends that a site specific water
treatment protocol which includes a passivation procedure that details the
desired water chemistry and visual inspections during the first six to twelve
weeks of operation be used. During this passivation period, recirculating
water pH should be maintained above 7.0 and below 8.0 at all times.
Recirculating Water System
The cooling in a tower is accomplished by the evaporation of a portion of the
recirculated spray water. As this water evaporates, it leaves behind mineral
content and impurities. Therefore, it is important to bleed-off an amount of
water proportional to that which is evaporated to prevent the buildup of impurities. If this is not done, the mineral content and/or the corrosive nature of
the water will continue to increase. This can ultimately result in heavy scaling
or a corrosive condition.
Bleed-off
Evaporative cooling equipment requires a bleed or blow-down line to
remove concentrated water from the system. The mineral concentration is
monitored by measuring the conductivity of the water. Evapco recommends
an automated conductivity controller to maximize the water efficiency of your
system. Based on recommendations from your water treatment supplier, the
conductivity controller should open and close a bleed valve to maintain the
conductivity of the recirculating water.
Control of Biological Contaminants
Evaporative cooling equipment should be inspected regularly to ensure
good microbiological control. Inspections should include both monitoring
of microbial populations via culturing techniques and visual inspections for
evidence of biofouling. Poor microbiological control can result in loss of
heat transfer efficiency, increase corrosion potential, and increase the risk of
pathogens such as those that can cause risk to health. If excessive microbiological contamination is detected, a more aggressive mechanical cleaning
and/or water treatment program should be undertaken.

Water Treatment
Proper water treatment is an essential part of the maintenance required
for all evaporative cooling equipment. A well designed and consistently
implemented water treatment program will help to ensure efficient system
operation while maximizing the equipments service life. A qualified water
treatment company should design a site specific water treatment protocol
based on equipment (including all metallurgies in the cooling system), location, makeup water quality and usage.

86

Structural Steel Support

Models AT/UT/USS 14-64 to 314-978


Suggested Two I-Beam Arrangement
L

Plan View

End Elevation

Models AT/UT/USS 14-64 through 110-918

Models AT/UT/USS 210-124 through 314-978

Two I-Beams Required (By Others)

2-CELL

Dimensions
L

14-64 to14-94

4 0-15/32

3 11-5/8

14-66 to 14-96

4 0-15/32

5 11-5/8

Model No.
2-CELL

Dimensions
W

29-121 to 29-921

8 5-1/2

21 0

29-024 to 29-924

8 5-1/2

24 2

14-69 to 14-99

4 0-15/32

8 11-11/16

29-228 to 29-928

8 5-1/2

28 2

14-612 to 14-912

4 0-15/32

11 11-5/8

210-124 to 210-924

9 9-3/4

24 2

19-56 to 19-96

5 11-7/8

8 5-1/2

210-136 to 210-936

9 9-3/4

36 2-1/2

19-28 to 19-98

7 5-7/8

8 5-1/2

212-024 to 212-924

11 10

24 2

19-59 to 19-99

8 5-1/2

8 11-1/2

212-128 to 212-928

11 10

28 2

19-111 to 19-911

8 5-1/2

10 5-1/2

212-036 to 212-936

11 10

36 2-1/2

19-412 to 19-912

8 5-1/2

11 11-3/4

212-0140 to 212-1640

11 10

40 2-1/4

19-114 to 19-914

8 5-1/2

13 11-3/4

214-0148 to214-1248

13 11-1/4

47 8-1/2

110-112 to 110-912

9 9-3/4

11 11-3/4

214-552 to 214-952

13 11-1/4

51 8-1/4

39-336 to 39-936

8 5-1/2

36 4-1/4

39-242 to 39-942

8 5-1/2

42 4-1/4

3-CELL

1-CELL

Model No.

Two I-Beams Required (By Others)

110-118 to 110-918

9 9-3/4

18 0

112-012 to 112-912

11 10

11 11-3/4

112-314 to 112-914

11 10

13 11-3/4

310-136 to 310-936

9 9-3/4

36 4-1/4

112-018 to 112-918

11 10

18 0

310-154 to 310-954

9 9-3/4

54 5

112-520 to 112-920

11 10

20 0

312-036 to 312-936

11 10

36 4-1/4

114-0124 to114-1324

13 11-1/4

23 9

312-042 to 312-942

11 10

42 4-1/4

114-526 to 114-926

13 11-1/4

25 8-7/8

312-054 to 312-954

11 10

54 5

26-517 to 26-917

5 11-7/8

17 1-1/2

312-260 to 312-960

11 10

60 5

28-217 to 28-917

7 5-7/8

17 1-1/2

314-0172 to 314-1272

13 11-1/4

71 8

29-318 to 29-918

8 5-1/2

18 0

314-578 to 314-978

13 11-1/4

77 7-5/8

Notes:
Models Listed Above.
1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative for factory certified steel support drawings.
2. The recommended support for the AT/UT/USS Cooling Tower is structural I-beams located under the outer flanges and running the entire length of the unit. The unit
should be elevated to allow access underneath the unit and to the roof below. Mounting holes, 3/4 in diameter, are located in the bottom flanges of the pan to provide for
bolting to the structural steel.
3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit length, not to exceed 1/2.
4. For these models where two support beams are required, deflection may be calculated by using 55% of the operating weight as a uniform load on each beam.
5. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the I-beams.
6. Support beams and Anchor bolts are to be furnished by others.
7. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions.
8. For alternate layout arrangements please consult the factory. NOTE: OPTIONALBOTTOMCONNECTIONSWILLREQUIRETHEUNITTOBEELEVATED TO ALLOW
FOR PIPING.

87

Structural Steel Support

Models AT/UT/USS 212-59 to 428-952


Suggested Three I-Beam Arrangement

End Elevation
Plan View

Models AT/UT/USS 212-59 through 428-952


Three I-Beams Required (By Others)

4-CELL

2-CELL

Model No.

Dimensions
W

212-59 to 212-99

12 4-7/8

8 5-1/2

215-29 to 215-99

15 4-7/8

8 5-1/2

217-59 to 217-99

17 4-1/8

8 11-1/2

217-111 to 217-911

17 4-1/8

10 5-1/2

217-412 to 217-912

17 4-1/8

11 11-3/4

217-214 to 217-914

17 4-1/8

13 11-3/4

220-112 to 220-912

20 0-5/8

11 11-3/4

220-118 to 220-918

20 0-5/8

18 0

224-018 to 224-918

24 1-1/8

18 0

224-720 to 224-920

24 1-1/8

20 0

228-0124 to 228-1024

28 3-5/8

23 9

228-526 to 228-926

28 3-5/8

25 8-7/8

420-124 to 420-924

20 0-5/8

24 1-3/4

420-136 to 420-936

20 0-5/8

36 2-1/4

424-024 to424-924

24 1-1/8

24 1-3/4

424-028 to 424-928

24 1-1/8

28 1-3/4

424-036 to 424-936

24 1-1/8

36 2-1/4

424-0140 to 424-1640

24 1-1/8

40 2-1/4

428-0148 to 428-1348

28 3-5/8

51 1

428-552 to 428-952
28 3-5/8
55 0-3/4
Notes:
Models Listed Above.
1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative for factory certified steel support drawings.
2. The recommended support for the AT/UT/USS Cooling Tower is structural I-beams located under the outer flanges and running the entire length of the unit. The unit should
be elevated to allow access underneath the unit and to the roof below. Mounting holes, 3/4 in diameter are located in the bottom flanges of the pan to provide for bolting
to the structural steel.
3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit length, not to exceed 1/2.
4. For these models only where three support beams are required, deflection may be calculated using 56% of the operating weight on the CENTERBEAM and 22% on each
OUTBOARDbeam.
5. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the I-beams.
6. Support beams and Anchor bolts are to be furnished by others.
7. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions.
8. For alternate layout arrangements please consult the factory. NOTE: OPTIONAL BOTTOM CONNECTIONS WILL REQUIRE THE UNIT TO BE ELEVATED TO ALLOW
FOR PIPING.
88

Structural Steel Support


Models AT/UT/USS 342-526 to 342-926
Suggested Four I-Beam Arrangement

End Elevation

Plan View

Models AT/UT/USS 456-526 to 456-926


Suggested Five I-Beam Arrangement

End Elevation

Plan View

Models AT/UT/USS 342-526 through 456-926


I-Beams Required (By Others)
Dimensions

Model No.

342-526 to 342-926
456-526 to 456-926

42 8
57 3/8

25 8-7/8
25 8-7/8

Notes:
Models Listed Above.
1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative for factory certified steel support drawings.
2. The recommended support for the AT/UT/USS Cooling Tower is structural I-beams located under the outer flanges and running the entire length of the unit. The unit
should be elevated to allow access underneath the unit and to the roof below. Mounting holes, 3/4 in diameter are located in the bottom flanges of the pan to provide for
bolting to the structural steel.
3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit length, not to exceed 1/2.
4. For these models only where four or five support beams are required, deflection may be calculated using 56% of the operating weight on the CENTERBEAMS and 22% on
each OUTBOARDbeam.
5. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the I-beams.
6. Support beams and Anchor bolts are to be furnished by others.
7. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions.
8. For alternate layout arrangements please consult the factory. NOTE: OPTIONAL BOTTOM CONNECTIONS WILL REQUIRE THE UNIT TO BE ELEVATED TO ALLOW FOR
PIPING.

89

Notes

90

OUR Products are Manufactured Worldwide.

World Headquarters/
Research and
Development Center
EVAPCO Facilities

EVAPCO, Inc. World Headquarters & Research/Development Center


P.O. Box 1300 Westminster, MD 21158 USA
410-756-2600 p 410-756-6450 f marketing@evapco.com
North America
EVAPCO, Inc.
World Headquarters
P.O. Box 1300
Westminster, MD 21158 USA
410-756-2600 p | 410-756-6450 f
marketing@evapco.com
EVAPCO East
5151 Allendale Lane
Taneytown, MD 21787 USA
410-756-2600 p | 410-756-6450 f
marketing@evapco.com
EVAPCO Midwest
1723 York Road
Greenup, IL 62428 USA
217-923-3431 p | 217-923-3300 f
evapcomw@evapcomw.com
EVAPCO West
1900 West Almond Avenue
Madera, CA 93637 USA
559-673-2207 p | 559-673-2378 f
contact@evapcowest.com
EVAPCO Iowa
925 Quality Drive
Lake View, IA 51450 USA
712-657-3223 p | 712-657-3226 f
EVAPCO Iowa
Sales & Engineering
215 1st Street, NE
P.O. Box 88
Medford, MN 55049 USA
507-446-8005 p | 507-446-8239 f
evapcomn@evapcomn.com
EVAPCO Newton
701 East Jourdan Street
Newton, IL 62448 USA
618-783-3433 | 618-783-3499 f
evapcomw@evapcomw.com

1M/0613/YGS

Bulletin 331F

EVAPCOLD
521 Evapco Drive
Greenup, Ill USA
217-923-3431 p
evapcomw@evapcomw.com
EVAPCO-BLCT Dry Cooling, Inc.
981 US Highway 22 West
Bridgewater, New Jersey 08807 USA
1-908-379-2665 p
info@evapco-blct.com
Refrigeration Valves &
Systems Corporation
A wholly owned subsidiary of EVAPCO, Inc.
1520 Crosswind Dr.
Bryan, TX 77808 USA
979-778-0095 p | 979-778-0030 f
rvs@rvscorp.com

Europe

Asia/Pacific

EVAPCO Europe BVBA


European Headquarters
Industrieterrein Oost 4010
3700 Tongeren, Belgium
(32) 12-395029 p | (32) 12-238527 f
evapco.europe@evapco.be

EVAPCO Asia/Pacific Headquarters


1159 Luoning Rd. Baoshan Industrial Zone
Shanghai, P. R. China, Postal Code: 200949
(86) 21-6687-7786 p | (86) 21-6687-7008 f
marketing@evapcochina.com

EVAPCO Europe, S.r.l.


Via Ciro Menotti 10
I-20017 Passirana di Rho
Milan, Italy
(39) 02-939-9041 p | (39) 02-935-00840 f
evapcoeurope@evapco.it
EVAPCO Europe, S.r.l.
Via Dosso 2
23020 Piateda Sondrio, Italy

EVAPCO Northwest
5775 S.W. Jean Road, Suite 104
Lake Oswego, Oregon 97035 USA
503-639-2137 p | 503-639-1800 f

EVAPCO Europe GmbH


Meerbuscher Strae 64-78
Haus 5
40670 Meerbusch, Germany
(49) 2159-69560 p | (49) 2159-695611 f
info@evapco.de

EvapTech, Inc.
A wholly owned subsidiary of EVAPCO, Inc.
8331 Nieman Road
Lenexa, KS 66214 USA
913-322-5165 p | 913-322-5166 f
marketing@evaptech.com

Flex coil a/s


A wholly owned subsidiary of EVAPCO, Inc.
Knsgrdvej 115
DK-9440 Aabybro Denmark
(45) 9824 4999 p | (45) 9824 4990 f
info@flexcoil.dk

Tower Components, Inc.


A wholly owned subsidiary of EVAPCO, Inc.

EVAPCO S.A. (Pty.) Ltd.


A licensed manufacturer of EVAPCO, Inc.
18 Quality Road
Isando 1600
Republic of South Africa
(27) 11-392-6630 p | (27) 11-392-6615 f
evapco@evapco.co.za

5960 US HWY 64E


Ramseur, NC 27316
336-824-2102 p | 336-824-2190 f
mail@towercomponentsinc.com

South America
EVAPCO SEMCO
Equipamentos de Refrigeracao Ltda.
Rua Alexandre Dumas, 1601 - 2 andar
04717-004 Sao Paulo - SP - Brazil
(55) 11-5184-0067 p

Evap Egypt Engineering Industries Co.


A licensed manufacturer of EVAPCO, Inc.
5 El Nasr Road
Nasr City, Cairo, Egypt
2 02 24022866 /2 02 24044997 p
2 02 24044667/2 02 24044668 f
Primacool@link.net / Shady@primacool.net

EVAPCO (Shanghai) Refrigeration


Equipment Co., Ltd.
1159 Luoning Rd., Baoshan Industrial Zone
Shanghai, P.R. China, Postal Code: 200949
(86) 21-6687-7786 p | (86) 21-6687-7008 f
marketing@evapcochina.com
Beijing EVAPCO Refrigeration
Equipment Co., Ltd.
Yan Qi Industrial Development District
Huai Rou County
Beijing, P.R. China, Postal Code: 101407
(86) 10 6166-7238 p | (86) 10 6166-7395 f
evapcobj@evapcochina.com
EVAPCO Australia (Pty.) Ltd.
34-42 Melbourne Road
P.O. Box 436
Riverstone, N.S.W. Australia 2765
(61) 2 9627-3322 p | (61) 2 9627-1715 f
E-mail: sales@evapco.com.au
EVAPCO Composites Sdn. Bhd
No. 70 (Lot 1289) Jalan Industri 2/3
Rawang Integrated Industrial Park
Rawang, Selangor, 48000 Malaysia
60 3 6092-2209 p | 60 3 6092-2210 f
EvapTech Asia Pacific Sdn. Bhd
A wholly owned subsidiary of EvapTech, Inc.
B-6-1, IOI Boulevard
Jalan Kenari 5, Bandar Puchong Jaya
47170 Puchong, Selangor Darul Ehsan
Malaysia
(60-3) 8070-7255 p | (60-3) 8070-5731 f
E-mail: marketing-ap@evaptech.com

Visit us at evapco.com.

Committed to making life easier, more reliable and more sustainable for people everywhere

2015 EVAPCO, Inc.

Vous aimerez peut-être aussi