TM
NO
CORROSION
CORROSION
RESISTANT
UV RESISTANT
01 www.astralcpvc.com
COMPANY PROFILE
Santej Plant
first time in India in 1999 and changed the history of Indian Plumbing
Industry. Today ASTRAL is undoubtably leader in CPVC plumbing system.
ASTRAL is known for innovative products and within 15 years of its
existence, ASTRAL has introduced so many products that are ahead of the
time, like CPVC fire sprinkler system, CPVC-AL-CPVC multi layer pipes,
Foamcore multilayer pipes, Underground drainage system, Lead free
Column Pipes for submersible pumps, piping system for soil, waste and rain
water and click ring type uPVC drain waste and vent system.
Dholka Plant
Hosur Plant
www.astralcpvc.com 02
INTRODUCTION
standards.
INTRODUCTION :
COLOUR
ASTRAL WIRE GUARDTM electrical conduits are available in
TM
-0.3
Min.
ID
17.4
Light
Min. Wall
Thickness
1.15
Max. Wall
Thickness
1.30
Min.
ID
16.90
Medium
Min. Wall
Thickness
1.40
Max. Wall
Thickness
1.55
Min.
ID
15.80
Heavy
Min. Wall
Thickness
1.95
Max. Wall
Thickness
2.10
25
-0.4
22.1
1.25
1.45
21.40
1.60
1.80
20.60
2.00
2.20
32
-0.4
28.6
1.50
1.70
27.80
1.90
2.10
26.60
2.50
2.70
40
-0.4
35.8
1.90
2.10
35.40
2.10
2.30
34.40
2.60
2.80
50
-0.5
45.1
2.20
2.45
44.30
2.60
2.85
43.20
3.15
3.40
63
-0.6
57.0
2.70
3.00
Out Side
Diameter
in mm
Tolerance
on OD
20
03 www.astralcpvc.com
ADVANTAGES
ADVANTAGES
HIGH CORROSION RESISTANCE
ASTRAL WIRE GUARDTM is non-corrosive
by nature and are not attacked by
corrosive, salty atmosphere & excessive
humidity. They are immune to chemical
and galvanic corrosion. Hence they are
ideal electrical conduits.
FIRE RESISTANCE
ASTRAL WIRE GUARDTM do not support
combustion and when the source of
ignition is removed they are self
extinguishing.
CONDUCTIVITY
ASTRAL WIRE GUARDTM is non-conductor
of electricity. ASTRAL WIRE GUARDTM
conduit prevents electrical shocks.
Hence they are most suitable for
electrical conduits.
LIGHTWEIGHT
ASTRAL WIRE GUARDTM have low specific
gravity, which implies that it is much
lighter than the pipes made from more
traditional materials. ASTRAL Pipes are
therefore easier to handle. This result in
reduced transportation & installation
costs.
EASY WIRING
ASTRAL WIRE GUARDTM have smooth
interior walls which helps in reducing the
friction thus helping in easy wiring.
EASY INSTALLATION
ASTRAL WIRE GUARDTM can be shaped
and joined without difficulty.
ASTRAL WIRE GUARDTM Pipes are joined
by solvent cement, which is simpler,
cheaper & easier.
STRENGTH
ASTRAL WIRE GUARD TM have high
mechanical strength that is attested by
tests conduced as specified in IS 9537: 3.
Hence they can be used both in open /
surface and concealed installation.
NO MAINTENANCE
ASTRAL WIRE GUARDTM requires no
maintenance due to its excellent
weather protected properties.
DURABILITY
ASTRAL WIRE GUARD T M electrical
conduit pipes last for a lifetime.
VERSATILE AND ELEGANT
The physical properties of PVC allow
designers a high degree of freedom
while designing. Superior finished
pipes and fittings add a touch of
beauty to the buildings .
ENVIRONMENTAL IMPACT
PVC has a lower feedstock energy
especially compared to other polymers
and common building materials. It is
the least energy intensive of all
thermoplastics. In life cycle analysis
and independent studies, PVC's
environmental impact has been found
most favorable, so the more usage of
PVC will greatly help to keep our global
natural resources intake for longer
period of time. It is not polluting air,
water or land during manufacturing or
service life and can be recycled after
prolonged service life.
www.astralcpvc.com 04
TECHNICAL SPECIFICATIONS
BASIC PHYSICAL PROPERTIES
PROPERTY
GENERAL
Specific Gravity
Water Absorption
Rockwell Hardness
TEST METHOD
CONDITION
ASTM D792
ASTM D570
ASTM D785
MECHANICAL
Izod Impact
ASTM D256
Tensile Strength
ASTM D638
Tensile Modulus
ASTM D638
Flexural Strength
ASTM D790
Flexural Modulus
ASTM D790
Compressive Strength
ASTM D695
Compressive Modulus
ASTM D695
THERMAL
Coefficient of Thermal
ASTM D696
Expansion
Thermal Conductivity
ASTM C177
Heat Distortion
ASTM D638
Temperature @ 66 psi
FIRE RESISTANCE PROPERTY
Flammability Rating
UL 94
Flame Spread
ASTM E84
Smoke Developed
ASTM E84
Limiting Oxygen Index
ASTM D2863
ELECTRICAL
Dielectric Strength
ASTM D147
Dielectric Constant
ASTM D150
Power Factor
ASTM D150
Volume Resistivity
ASTM D257
Insulation Resistance
ENGLISH UNITS
SI UNITS
73F / 23C
73F / 23C
212F / 100C
73F / 23C
1.40 to 1.46
+0.03%
+0.55%
119
1.40 to 1.46
+0.03%
+0.55%
------
73F / 23C
73F / 23C
73F / 23C
73F / 23C
73F / 23C
73F / 23C
73F / 23C
1.5 ft lbs/in
7000 psi
3,60,000 psi
15,100 psi
4,15,000 psi
9000 psi
1,96,000 psi
60 J/m
55 N/mm2
2500 N/mm2
104 N/mm2
2860 N/mm2
62 N/mm2
1350 N/mm2
0.14 Wm/K/m2
179F
80C
0.062 in/0.157 cm
60hz, 30F/-1C
60Hz 73F/23C
73F / 23C
1100
3.70
0.0096
4,30,000 V/cm
3.70
0.0096
15
5.4 x 10 ohm/cm
100
QUALITY CONTROL
ASTRAL is having well equipped quality testing laboratory in their plant as per the ISI
standards for testing of all PVC electrical conduits & accessories. The high quality
performance is attained with experienced and qualified staff and skilled workers.
Each batch of ASTRAL WIRE GUARDTM pipes & fittings are tested as per Bureau of
Indian Standards relevant scheme of testing and inspection. ASTRAL takes the
following acceptance and type tests in the laboratory before dispatch the
material.
BATCH WISE TESTING BEFORE DISPATCHING
1. Checking of dimensions
2.
Bending Test
3. Compression Test
4.
Impact Test
5. Collapse Test
6.
Resistance to Heat
7. Resistance to Burning
8.
Electrical Characteristics
05 www.astralcpvc.com
PRODUCT
PRODUCT
CODE
SIZE OD STANDARD
(mm)
PACK
PRODUCT
PRODUCT
CODE
SIZE OD STANDARD
(mm)
PACK
AC 600-020L - 3M
AC 600-025L - 3M
AC 600-032L - 3M
AC 600-040L - 3M
AC 600-050L - 3M
AC 600-063L - 3M
AC 600-020L -SS - 3M
AC 600-025L -SS - 3M
AC 600-032L -SS - 3M
AC 600-040L -SS - 3M
AC 600-050L -SS - 3M
AC 600-063L -SS - 3M
20
25
32
40
50
63
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
18 x 3 mtr
20
25
32
40
50
63
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
18 x 3 mtr
AC 600-020M - 3M
AC 600-025M - 3M
AC 600-032M - 3M
AC 600-040M - 3M
AC 600-050M - 3M
AC 600-020M - SS - 3M
AC 600-025M - SS - 3M
AC 600-032M - SS - 3M
AC 600-040M - SS - 3M
AC 600-050M - SS - 3M
20
25
32
40
50
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
20
25
32
40
50
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
AC 600-020H - 3M
AC 600-025H - 3M
AC 600-032H - 3M
AC 600-040H - 3M
AC 600-050H - 3M
AC 600-020H - SS - 3M
AC 600-025H - SS - 3M
AC 600-032H - SS - 3M
AC 600-040H - SS - 3M
AC 600-050H - SS - 3M
20
25
32
40
50
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
20
25
32
40
50
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
AC 210 - 201
AC 210 - 251
AC 210 - 202 T
AC 210 - 252 T
20
25
20
15
20
25
20
25
20
15
AC 210 - 203
AC 210 - 253
20
25
20
15
www.astralcpvc.com 06
PRODUCT
CODE
SIZE OD
(mm)
STANDARD
PACK
PRODUCT
CODE
PRODUCT
LOOP IN BOX
AC 210 - 204*
AC 210 - 254*
AC 212 - 020
20
25
20
15
CIRCULAR LID
AC 220 - 201*
AC 220 - 251*
AC 200 - 065
20
25
10
10
REDUCER
AC 220 - 202 A*
AC 220 - 252 A*
AC 237 - 252
20
25
10
10
20
25
10
10
20
25
10
10
20
25
10
10
20
25
20
20
20
25
20
20
20
25
15
20
SIZE OD
(mm)
STANDARD
PACK
20
30
65
150
25 > 20
250
20
25
32
40
50
200
125
60
30
20
20
25
32
40
50
63
50
25
15
5
4
4
20
25
32
40
50
30
15
5
1
1
COUPLER
AC 229 - 020
AC 229 - 025
AC 229 - 032
AC 229 - 040
AC 229 - 050
SLIP TYPE BEND
AC 209 - 020*
AC 209 - 025*
AC 209 - 032*
AC 209 - 040
AC 209 - 050
AC 209 - 063
SLIP TYPE BEND (ISI)
AC 209 - 020 I
AC 209 - 025 I
AC 209 - 032 I
AC 209 - 040 I
AC 209 - 050 I
20
25
32
40
50
200
100
75
50
25
20
200
20
25
50
40
07 www.astralcpvc.com
PRODUCT
PRODUCT
CODE
SIZE OD
(mm)
STANDARD
PACK
20
25
32
40
50
63
200
150
100
100
100
50
20
25
200
150
20
25
125
75
20
25
50
50
20
25
125
75
AC 261 - 643*
AC 261 - 993*
AC 261 - 124*
75x75x50
3'x3'x2'
110x110x75
4'x4'x3'
160x110x75
6'x4'x3'
160x160x75
6'x6'x3'
225x225x75
9'x9'x3'
300x300x110
12'x12'x4'
10
1
1
1
1
1
75x75x63
3'x3'x2.5'
160x75x63
AC 264 - 633* 6'x3'x2.5'
AC 264 - 333*
10
10
AC 262 - 063*
75x75
3'x3'
160x75
6'x3'
12
10
INSPECTION TEE
AC 202 - 020*
AC 202 - 025*
AC 261 - 443*
AC 262 - 033*
INSPECTION ELBOW
AC 207 - 020*
AC 207 - 025*
STANDARD
PACK
ROUND TEE
AC 201 - 020
AC 201 - 025
AC 261 - 332*
AC 261 - 663*
ROUND ELBOW
AC 206 - 020
AC 206 - 025
SIZE OD
(mm)
SADDLE STRAP
AC 241 - 020
AC 241 - 025
PRODUCT
CODE
PRODUCT
20
25
50
25
20
25
40
20
AC 263 - 033*
AC 263 - 063*
3'x3'
75x75
6'x3'
160x75
60
75
INSPECTION BEND
AC 208 - 020*
AC 208 - 025*
*EXPANSION JOINT
* Introducing very shortly
Size
250 ML
500 ML
1000 ML
Std. Pkg.
24
12
12
www.astralcpvc.com 08
INSTALLATION
INSTALLATION PROCEDURES
Open
Concealed : Make a slot of appropriate width in wall, fix pipe in slot and cover with mortar.
RECOMMENDED PRACTICE
ASTRAL WIRE GUARDTM non-metallic conduits are so
constructed that it will be possible to bend the conduit
easily with the aid of bending spring and all conduits and
conduit fittings are of unthreaded type. The number of
single core, PVC insulated non-sheathed cables run in one
conduit shall be such that it permits easy drawing of the
CAPACITY OF CONDUITS
TABLE - 01
TABLE - 02
20
11
8
5
4
2
2
-
25
10
7
4
3
2
-
63
10
7
6
TABLE - 03
20
8
6
4
3
-
25
8
6
3
2
-
63
9
7
5
TABLE - 04
TM
20
6
4
3
2
-
63
12
7
6
4
3
CABLE FACTOR
Nominal Cross
Sectional area
of conductor mm 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0
Cable Factor
22 30 43 58 105 121 193 253 342 451
TABLE - 05
ASTRAL WIRE GUARDTM FACTOR
Conduit Size mm
upto 10 mtr.
Without Bend
Upto 10 mtr.
with 1 Bend
Upto 10 mtr.
With 2 Bend
20
25
32
40
50
63
244
442
783
1092
1943
2715
196
358
643
883
1571
2429
141
260
474
646
1149
1527
For each size of cable it is intended to use, obtain the appropriate factor from Table 4. Add all the cable factors so obtained and
compare with the conduit factor given in Table 5.
The conduit size which will satisfactorily accommodate the cables is that size having a factor equal to or exceeding the sum of the
cable factor.
09 www.astralcpvc.com
Total Temp.
Length of
Change F X Run Ft. X 0.36
10
X
100
Temperature Change in F
www.astralcpvc.com 10
JOINING METHOD
JOINING METHOD
1. CUT PIPE : Cut pipe square. As joints are sealed at the
failure.
reduced.
Do not throw or drop pipes, or drag them along hard
surfaces.
In case of mechanical handling, use protective slings
and padded supports. Metal chains and hooks should
not make direct contact with the pipe.
ON-SITE STORAGE
ASTRAL WIRE GUARD Conduit pipe and fittings may
be stored indoors or outside. If stored outside, pipe and
fittings should be protected from direct exposure to
sunlight and pipe should be properly supported in
storage to prevent sagging or bending. Pipe should be
BRANCH OFFICES:
Mumbai : Phone : (022)
New Delhi : Phone : (011)
Bengaluru : Telefax : (080)
Hyderabad : Telefax : (040)
Chennai : Phone : (044)
Jaipur
: Phone : (0141)
Lucknow : Phone : (0522)
Kochi
: Phone : (0484)
Follow us on :
2686
2616
2661
2790
4350
2360
2728
3328
2227
8156
7236
0023
6384
236
844
156
E-mail : mumbai@astralcpvc.com
E-mail : delhi@astralcpvc.com
E-mail : bgloffice@astralcpvc.com
E-mail : hyderabad@astralcpvc.com
E-mail : chennai@astralcpvc.com
E-mail : jaipur@astralcpvc.com
E-mail : lucknow@astralcpvc.com
E-mail : kochi@astralcpvc.com
App Available on :
Authorised Distributor :
All information contained in this manual is given in good faith and believed to be accurate and reliable. But because of many factors which are outside our knowledge and control and affect
use of product, no warranty is given or is to be implied with respect to such information, nor we offer any warranty of immunity against patent infringement. No responsibility can be accepted
for any error, omissions or incorrect assumptions. Any specification can change without prior notice.
AWG/PCG/000
REV:00/09/14
design@spectrumadvt.in
CIN : L25200GJ1996PLC029134