Vous êtes sur la page 1sur 260

EnC-OPEN-11 0

A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice.
To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I. factory.
A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.
A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988

ABOUT US

Who We Are

With over 40 years of industry experience, commitment to service, reliability and innovation, A.R.I. is a leading manufacturer and provider of
solutions for the protection of liquid transmission systems worldwide. The company manufactures and markets a complete line of air valves, check
valves, and unmeasured flow reducers (UFR) as well as providing software system analyses for surge and air valve sizing and placement.
ARI markets its product and analysis solutions in the following markets:
Water supply and wastewater disposal systems (urban and rural).
Industrial applications (desalination plants, mining and gas industries, hot water systems).
Agriculture and landscape.
ARI is firmly committed to quality and to protecting the environment and is ISO 9001 and ISO14001 certified.
Founded in Israel, A.R.I. now has branches in the United States, Germany, Russia, China, South Africa, France, Brazil and markets in over 90
countries worldwide.

What We Do

A.R.I. system solutions protect the pipeline from destructive forces such as surge, pressure transients and entrapped air. These are the leading causes
of pipeline bursts, fractures and cracks which cause irreparable environmental damages such as water losses from leaks, pathogen and contaminant
intrusion through pipe cracks and energy losses from inefficient flows. A.R.I. is committed to solving these problems by providing a system analyses
that helps reduce surge related phenomena by selecting the most efficient A.R.I. air valves and size and locate them on the liquid transmission system.
Another innovative product which reduces water losses in the consumer market is the Unmeasured Flow Reducer (UFR). The UFR, installed near
the water meter, will detect household leaks and change the flow regime to enable the measurement of previously unmeasured water flow into the
home.

What We Offer

A.R.I. bases its success on its three marketing strengths; sustainable products, excellent customer service and support, and innovation. A.R.I. successes
have propelled the company to be recognized as a world leader in the irrigation and wastewater air valve market as well as enjoy a significant presence
in the water transmission market. The companys ongoing ability to provide its customers with learning tools and hands-on training has increased
their awareness and ability to conserve water and energy, reduce water pollution, and reduce water losses in all types of pressurized liquid transmission
systems.
A.R.I. introduced the revolutionary concept of providing, not only innovative products, but also customized solutions for the protection of liquid
transmission systems. These software aided solutions changed the rules of the game by bringing the customer and the solution provider in closer
contact.

What Defines Us

EnC-IMAGE-11 1

A.R.I. remains in close contact with the customer and provides him with training seminars and technical material, giving the client the knowledge
necessary to analyze and choose the appropriate method of protection for the transmission system. A.R.I. products comply with international
standards. The company has registered over 7 patents to protect its intellectual property throughout the world. A.R.I. employees are position trained
on a high level, both technically and academically, in addition to having vast work experience. A.R.I. has the ability to analyze the customers needs
in terms of protecting his water systems from surge and pressure changes, and advise him how to protect his system from physical damage and reduce
water losses, save energy and prevent water contamination and pathogen intrusion.

THE ENVIRONMENT AND US

Products for Helping the Environment

A.R.I is committed to minimizing the impact of its activities on the environment (See: A.R.I Environment Policy Statement below). We see our
mission as not only to protect the environment from within the company but also to provide product lines that help others to reduce damaging
effects to the environment. ARI products will reduce pathogen and contaminant intrusion into potable water systems, pathogen and contaminant
seepage from wastewater systems into water sources (ground water, lakes, ponds etc.) and revenue and non-revenue water losses.
Using the software program analyses of ARIavCAD and Surge 2010, A.R.I surge reducing air valves can be strategically placed on water and
wastewater transmissions systems to reduce the damaging effects of pressure transients which cause pipe burst, fractures and cracks and their
subsequent water losses.
The A.R.I Unmeasured Flow Reducer (UFR) is used on household water lines adjacent to the water meter to detect leaks in the system and also
change the flow regimen to enable measuring of water that was previously immeasurable.

A.R.I. Environment Policy Statement

The management of A.R.I. Flow Control Accessories LTD. will act to reduce and eliminate the environmental consequences resulting from its
operations by a system based on environmental management standard ISO 14001:2004, while maintaining the appropriate safety conditions. The
company management and its workers are committed to constantly maintain and improve the environmental quality of the firm and its activities.
The company has set for itself a work plan for achieving its objectives in the pursuance of environmental quality.
A.R.I. Flow Control Accessories LTD. products will contribute to the improvement of the quality of the environment. The management of A.R.I.
Flow Control Accessories LTD. will direct resources to increase product development and applications that contribute to improvement of the quality
of the environment.
This policy stance will be implemented according to the following objectives:
Create a strong awareness among all employees of issues on environmental quality.
Take initiatives to examine environmental aspects of the company while maintaining high performance levels.
Meet all requirements and uphold all laws, orders, regulations and other requirements in the field of environmental quality.
For reducing the environmental impact the following steps will be taken:
The management of A.R.I. Flow Control Accessories LTD. will set each year an annual work plan which will determine the goals for that year.
A report on actions taken and objectives achieved within the framework of the annual work plan will be prepared and presented to the Board of
Directors of the company as well as to the authorities responsible for protecting the environment.
The companys environmental policy, within the framework of ISO 14001:2004, will be set forth in this document, disseminated to all company
employees and assimilated through procedures and training and will be available to the public.
The management of A.R.I. Flow Control Accessories LTD. will define, as is possible, clear and measurable environmental objectives and aspire to
meet them at all times.
The management of A.R.I. Flow Control Accessories LTD. will dedicate the resources and means necessary to ensure the reduction and elimination
of all damaging influences on the environment as a result of activities such as: sewage, land pollution, solid waste disposal, etc.
The management of A.R.I. Flow Control Accessories LTD. and its employees see themselves as responsible, committed and involved in all aspects
of environment protection and implementing all environmental policies of the company.
The management of A.R.I. Flow Control Accessories LTD. will deal with all environmental issues relevant to its operations and brief its employees
in all aspects of the environmental management system it adopted.
The management of A.R.I. Flow Control Accessories LTD. will inform its customers and suppliers regarding the adopted environmental policy and
initiate information and training activities among its suppliers to enhance their awareness to the issues of environmental quality.
The management of A.R.I. Flow Control Accessories LTD. is aware that its factory operates in a rural environment situated near by natural water
sources and therefore will act accordingly and assign resources to perform the actions required to prevent environmental pollution to the region and
its water sources.
This environmental policy will be available to the general public and to all interested parties at all times and through various means.

A.R.I. Subsidiaries and Joint Ventures

A.R.I Aqua is the marketing arm of A.R.I. in Russia. The company was established in 2005.
The A.R.I Aqua offices and its logistics center are located in Moscow.
The operations director is Alexei Philkov who oversees the team of salespeople, administrators, warehousing staff and delivery personnel.
A.R.I Aqua also represents other companies in Russia besides A.R.I Aqua including:
Bermad, Kraus, Yamit and others.
A.R.I Aqua operates mainly in the fields of water and sewage.
Most of A.R.I Aqua ties are with the leading water companies in Russia.

AIRVALVE was established in 2003 in Germany together with two local partners.
The company specializes in the treatment of air in liquid transmission systems such as sewage, water, industrial and water treatment.
The company offers optimization services for air valves and hydraulic analyses for different liquid transmission systems.
The company markets and sells air valves for all types of applications and pressures up to 100 atmospheres.
AIRVALVE offices and its logistics center are located in the vicinity of the city of Dortmund.
The company managers, Bernie Hausman and Michael Giesel oversee a chain of agents, administrators, warehousing staff and delivery personnel.
The main customers of AIRVALVE are water companies, contractors and commercial businesses.

A.R.I. CHINA is the marketing representative of A.R.I. in China. The company was established in 2006.
The A.R.I. CHINA marketing system consists of territorial agents deployed across China.
The company operations manager is Mr. Goa, the administrative manager is Ms. Jolie and the marketing manager is Mr. Zhou.
A.R.I. CHINA and its managers provide logistical and engineering support to all the territorial agents as well as manage the company inventories.
A.R.I. CHINA is involved in most of the major projects in China. Their involvement begins already in the early planning stages, providing
recommendations for solving problems of surge in the pipeline as well as designing the location and sizing of the air valves.
The counseling and support provided by the company is in conjunction with the leading academics in the field, both from China and abroad.
Solution implementation combines the use of the A.R.I. product line together with the use of bladder tanks made by Charlotte, a company that is
represented in China by A.R.I. China.

EnC-IMAGE-11 3

A.R.I. AFRICA was established in 2000.


The company is a partnership between local businessmen and A.R.I. Israel.
The central offices of A.R.I. AFRICA are in Welkom with an additional office in Johannesburg.
Some of the products marketed in South Africa are also assembled there. This provides a service to the customer as well as shortening delivery times.
The products include air valves for water transmission and wastewater systems and provide for a wide range of solutions for the marketplace.
A.R.I. AFRICA provides design services to determine the placement and sizing of air valves, using ARIAVCAD, a software program developed
by A.R.I. The company also aids in providing solutions for preventing pipeline surges, combining design with the supply of appropriate products.
A.R.I. AFRICA products are approved for use in South Africa by most of the municipal water companies and water supply companies.

A.R.I. USA, Inc. was founded in 2002 as a corporation based in San Diego.
The company supplies ARI products and services to the municipal, water, wastewater and industrial markets in the United States and Canada.
The companys marketing network is comprised of 25 local manufacturers rep companies who have received exclusive rights in their defined
territories throughout North America.
The ARI USA technical team works hand-in-hand with design engineers and end-users, performing analysis for pipeline protection, including the
use of Air Valve Placement and Surge software.
The companys state-of-the-art third-party logistics center enables it to offer swift response and efficient supply, as well as on-line electronic tracking
of shipments.
A.R.I. USA, Inc. is proud to serve a consistently growing market with high quality products and a professional service team.

A.R.I. FRANCE Engineering Flow Control was established in 2011 in France.


The company specializes in solving air related problems in networks such as sewage, water, industrial and water treatment.
The company offers design services for the placement and sizing of air valves as well as hydraulic system analyses and recommended solutions for the
different liquid transmission systems. The company markets and sells air valves for all types of applications and pressures up to 100 atmospheres.
The main office of A.R.I. FRANCE Engineering Flow Control is located in Lille. Eng. Laurent Dupuis is responsible for providing all professional
services.
The main customers of the company are representatives, water companies and municipalities, contractors and commercial businesses.

A.R.I. BRASIL was established in 2011 and is the sales and marketingarmof A.R.I- Flow Control Accessories in Brazil.
The A.R.I BRASILmarketing format consists of territorial agents deployed across Brazil.
The company operations manager is Mr. Ari Fischer, and the marketing manager is Mr. CarlosGodoy.
A.R.I. BRASILprovidessales,marketing, engineering andlogisticalsupport to all the territorial agents as well asto the end user.The company will
supply products and services to the municipal, water, wastewater and industrial markets.
A.R.I. BRASILis involved inmajor projects in Brazil. Involvement begins in the early planning stages, providinganalysis and recommendations for
solving problems ofpipelineprotection from surge and vacuumas well as designing the location and sizing of the air valves.
The counseling and support provided by the company are in conjunction with the leadingexpertsin the field, both from Braziland abroad.

OUR PROFESSIONAL SUPPORT TEAM

Applications Engineering Dept.

The main attributes of the A.R.I. Dept. of Applications Engineering are its professionalism and its commitment to the customer and to the
engineers and consultants who serve these customers. They include the obligation to share knowledge with the customer as well as to train the
market. The Applications engineering personnel have the ability to view the customers needs through their own eyes. They can provide
the clients with professional guidance by understanding the special needs of each marketplace and supply applicable solutions.
Each applications engineer is assigned a geographical area and supports that area with hands-on guidance and with organized presentations and
seminars. They travel extensively and provide their services on-site at the customers facilities.
In addition, the dept. is well trained in providing solutions for pressure transients and surge problems in pipelines. Using the latest software, both
ARIavCAD and Pipe 2010, the applications engineers can analyze the pipeline and provide the best solutions for reducing the damaging effects
caused by these pressure and other hydraulic phenomena. They also provide data reports on the optimum placement and sizing of air valves on
the pipeline.
The main benefits of these abovementioned solutions are lower energy costs, a decrease in corrosion, surges, and pipe bursts, and a reduction in
pipeline fractures and cracking. These are the main causes for water loss and pathogen intrusion in the pipeline.
The applications engineering department also cooperates with numerous academic institutions worldwide by participating in research projects
that develop a better understanding of water conveyance systems. A result has been the publication of numerous articles and research works
documenting the results of these projects.

A Professional Air Flow Laboratory

The A.R.I. air flow laboratory is unique (the only one of its kind in the region) and is designed for testing air valves. The air flow lab was designed and
operates according to the ISO 17025 global standard and was adapted to meet the ISO 9001 quality standard and the ISO 14001 environmental
standard. Bench test assessments are carried out according to worldwide testing standards as well as the European standard EN 1074. The initial
calibration for the air flow lab was based on results from the CESAME (France) High Pressure Test Bench used for flow calibration and testing.
This lab calibrates large diameter gas meters based on the principle of the ORIFICE PLATE.
The A.R.I. air flow laboratory performs assessments of air flow rates during intake and discharge, air flow tests for air valve premature closure as well
as a vacuum bench test which tests the flow rate for air intake into air valves when the pipeline is under negative pressure.
These tests are carried out and calculated in accordance with international standards for moisture and temperature variables.
The air flow laboratory tests all types of air valves (air release, air & vacuum, combination, non-slam, one-way etc.) that operate on water and
wastewater systems and are in the diameter range of 1/2 to 12.
The air flow laboratory employs 4 air storage tanks, each one with a volume capacity of 10 cubic meters, plus an additional 10 cubic meter air tank
that is employed as the working tank.
The air is stored at 13 bar of pressure and enables testing of air valves up to 12 in diameter and, with an additional compressor, enables automatic
air valves to be tested at a pressure of 16 bars.

EnC-IMAGE-11 5

The air flow laboratory is computerized; therefore, once the characteristics of the tested air valves are entered in the computer and the air valve is
connected to the test bench, the test is run. At its conclusion, the test reports are immediately available on the computer without further processing.
The air flow lab is open to invited guests and trainees, who are able to view the testing and receive the results in real time, either viewed on a large
screen or printed as a hard copy.

A Professional Coatings Factory

In early 2010, A.R.I. opened up a new coatings factory for the fusion bonded coating process of all A.R.I. products. The equipment was purchased
specifically for the A.R.I. Coatings Factory. The technology and software components were specifically designed for the A.R.I. product line.
The main processes performed at the coatings factory include:
1- Preparation for painting - heating for the removal of gases, shot blasting and plugging of holes in the casting.
2- Painting - heating, powder coating and oven curing.
The painting process is controlled by monitoring sensors that collect and transfer all conveyor operation data during the entire process. This data is
transmitted to a central computerized controller that has the ability to control the process and change the operational regime of the system as need
be. The data, collected real-time in the computer, controls and documents the whole process. At the end of the coating process, a quality control
process is initiated which includes visual inspection, testing of coating thickness, coating continuity, durability and adhesion testing.
The coating system is adapted to process castings of small, medium and large diameters and is able to customize the process to meet specific
customer requirements for coating thickness. The shop operates on a schedule synchronized to meet required delivery dates as requested by A.R.I.
The coatings factory and its coating materials are certified for use on products intended for potable water systems (NSF certification) and are
supervised under the most stringent standards. The shop is also certified by the international standard ISO14000.

Quality Assurance

The goal of the QA dept. is to ensure the quality and integrity of the work processes in A.R.I. and with its suppliers. A.R.I. has developed numerous
specifications and procedures to ensure that the process from development, through receiving, production, assembly and the shipping of products
and services all meet A.R.I. client needs and requirements.
1- QA procedures are carried at both at the supplier and at A.R.I. and in cooperation with the customer.
The A.R.I. QA staff supports the suppliers worldwide where it carries out inspections and provides training. This ensures that items supplied to
A.R.I. will meet all specifications as defined by the engineering departments of A.R.I.
2- QA procedures in the support departments such as Procurement, Planning, R & D and Marketing.
The QA dept. oversees the compliance with established specifications and work procedures in accordance with market and product demands and
ensures that the procedures are set forth and documented as required in the specifications and stored in the A.R.I. information systems.
3- QA procedures in the operational departments such as Receiving, Warehousing, Assembly, Machining and Shipping.
The QA dept. carries out inspections to ensure the integrity of the process and its adherence to written procedures and specifications as follows:
- Receiving and inspection of the materials supplied and their proper storage.
- Identification of parts and parts traceability in the warehouses.
- Product assembly according to the product specifications details.
- Product testing and packaging.
- Handling and documentation of process deviations and product rejections.
4- Quality Assurance is carried out by the QA staff at various levels:
- Qualified quality controllers at the different work stations.
- Periodic audits in the various departments.
- Initiating operations improvements and taking corrective actions at every occurrence of a product failure or a customer complaint. This includes
a Materials Review Board (MRB) and a Customer Complaint Forum, both headed by the CEO of A.R.I.
Factory processes are examined and improved through computerized data collection and statistical reasoning, using test tools such as FMEA, etc.
Customer information sharing is done through direct communications, structured questionnaires and periodic meetings throughout the product
development stages.
The A.R.I. QA dept. is ISO 9001 certified since 2000 and ISO 14001 certified since 2009.

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

INTRODUCTION
Innovative Valves for Liquid Transmission Applications
A.R.I. Flow Control Accessories is among the world leaders in the development, manufacture and distribution of liquid transmission accessories.
A.R.I. engineers have developed a wide range of sophisticated valves made from various types of metals and composite materials. The valves are
designed for a variety of applications. Our engineers are working constantly to broaden the range of products, improve and enhance existing product
lines and develop new product lines. We incorporate the highest standards of quality control in compliance with Israeli and international standards.
Most of the A.R.I. products are protected by registered patents. A.R.I. operations, development and marketing systems comply with the requirements
of the international ISO 9001 and ISO 14000 standards and are certified as such.

The A.R.I. Commitment

A.R.I. is committed to respond to the needs of a changing market. To do so, we strive for a high standard of quality, innovation and advanced
technological development as our principal objective.
At A.R.I., we focus on providing products with longevity and minimal maintenance. We offer a comprehensive warranty, excellent service, consulting
and training for each customer at the plant, in the field or at any installation site, as necessary.

Air Valves
The A.R.I. line of automatic air release valves and the automatic air release components of A.R.I. combination air valves are based on the rolling seal
technology. The A.R.I. patented sealing mechanism replaces traditional configurations that incorporate a ball float closing against a round orifice.
While the system is under pressure the A.R.I. rolling seal mechanism, with its aerodynamically-designed float, releases air in large quantities, often
greater than in traditional valves. They also provide for the soft dynamic closure of the valve. This concept of a rolling seal mechanism enabled A.R.I.
to develop small, lightweight, cost effective air valves.
The self-cleaning feature of the rolling seal mechanism greatly reduces the possibility of clogging, leaking and the adhesion of suspended particles to
the rolling seal surface.
The valve body and interior components are made of corrosion-resistant materials. This ensures years of corrosion-free and maintenance-free
operation, even under extreme environmental conditions.
The A.R.I. line of products also includes a wide variety of air & vacuum and combination air valves. They are made of the same quality materials as
the automatic air release valves and provide the same level of quality and assurances.
These valves are offered in dimensions of 1/2 to 1 (automatic air release valves) and 1" to 12"(air & vacuum and combination air valves). They
provide solutions for various applications in all industrial fields. These products are lightweight, have a compact profile and are offered at competitive
prices.

Air in Liquid Transmission System

The quantity of free air must be controlled in liquid transmission systems. The presence of air/gas bubbles and pockets can be beneficial or
detrimental to the transmission system under different conditions. The absence of air, such as exist under vacuum conditions, prevents suitable
protection for the transmission systems.

Damage caused by the presence of air in the system

EnC-intrWTR/SWG-11 7

1. Air blockage in the line causes unstable flow of the liquid and, in extreme circumstances, a total stoppage of flow.
2. High head losses, resulting in large energy losses.
3 The impact of surge, as a result of the presence of air in the system, can cause damage to pipes, accessories and connectors.
4. Erroneous readings of water meters and automatic metering valves.
5. Extensive damage to impeller systems in water meters, flow regulators, sprinklers and sprayers.
6. Pitting and increased corrosion in metal components of the systems.
7. Safety risks to operators increase due to the possibility of high energy bursts in locations where there are concentrations of compressed air.

Damage caused by the absence of air in the system

Vacuum enhanced problems and damages:


- Suction of mud and dirt through faulty connections, cracks in pipes and accessories, etc.
- Suction of seals and gaskets, inline fittings, and other internal accessories of pipes.
- Uncontrolled suction of injected chemicals into the system.
- Pipe or accessory collapse.
- In some cases, the absence of an air cushion can increase the damages of surge and slam phenomena.

INTRODUCTION
Using A.R.I Air Valves to Control Air and Prevent Damage

There are three principal types of air valves used in liquid transmission applications:
Air & Vacuum Valves
Automatic Air Release Valves
Combination (double orifice) Air Valves
Air & Vacuum Valves automatically discharge air at high flow rates during filling of the system and admit air at high flow rates during draining, at
water column separation, and in cases of down-surge in the system.
Air & vacuum valves are known also as: large orifice air valves, vacuum breakers, low-pressure air valves and air vacuum valves.
Automatic Air Release Valves release air entrapped in the system while under pressure. The air release flow rates of the automatic air release valves
are lower than those of the air & vacuum valves. They are also known as: air release valves and small orifice air valves.
Combination Air Valves include both air & vacuum and automatic air release components in one unit. They perform both functions:
- They discharge air at high flow rates during filling of the system and admit air at high flow rates at drainage or water column separation, AND
- They release entrapped air while the system is under pressure.
Combination air valves are also known as double orifice air valves.

Installation and Location

It is highly recommended that a basic review be made before selecting the appropriate air valves and determining their sizes and locations:
- The chemical composition of the liquid that passes through them.
- The possibility of extreme pressure changes such as up-surges and down-surges.
- Analysis using ARIavCAD software for efficient design of the system (software available from A.R.I).
Typical installation locations:
- In pump stations.
- At locations where pressure drops.
- At peaks along the line.
- At locations of large convex slope changes
- Along line segments without air valves.
- Near isolating valves on the line.
- On filter setups.
- Before flow meters and automatic devices.
- At line ends.

INTRODUCTION
Recommendations for the Determination of the Required Diameter of Air &
Vacuum and Combination Air Valves
To determine the diameter of air valve required, the first essential step is to define the task that the air valve must perform and the level of protection
that the valve must provide.

The principle tasks of an air valve are:

1 - The controlled or free discharge of air during the line filling stage:
A. Controlled discharge The air valve diameter is determined in order to limit flow / filling speed.
B. Free discharge The air valve is used to discharge air during line filling, but is not used to limit flow / filling speed.
2- Intake of air to prevent negative pressure (vacuum), down-surge and/or cavitation:
A. When the line is drained through drainage valves with a defined location and size.
B. When the line bursts at predefined or not defined points along its length; it's bursting up to a pre-determined size of burst in the pipe and the free
drainage of water out of the line through the burst.
C. When there is water column separation consequential to extreme changes in the regimen of water flow through the pipe.
The required air flow rate and the air valve diameter are determined in accordance with the objective sought when installing the air valve
and as explained below:
- If the purpose of the air valve is only to limit filling speed the required air release speed is equal to the filling rate (for the system), which is a
function of the required filling rate.
- If the purpose of the air valve is to protect the system in the event of an burst, which splits the pipe across its entire cross section, with
consequential free flowing drainage of the line, the accepted method is to determine the required rate of air intake according to a burst analysis
based on one of the flow equations, such as the Hazen Williams equation:

Burst Analysis
The burst analysis is based on the Hazen Williams Equation:

Q B =KC H W D 2 . 63 ( h f / L a c t ) 0 .5 4 a nd L a c t = ( h f 2 +L hp 2 ) 0 .5
Where, in our case:

Q B = Air intake flow rate requirement for vacuum protection at full diameter pipe burst m /sec
K = Unit constant = 0.278 for metric units
C H W = Hazen Williams Coefficient for the pipen- no units
D = Diameter of pipe m
h f = Elevation change between the two ends of the pipe segment being analyzed m
L a c t = Actual length of the pipe segment (not its horizontal projection)- m
L h p = Length of the horizontal projection of the pipe segment - m
3

EnC-intrWTR/SWG-11 9

Given that the results of this analysis are often extreme, the common practice is to supply air at a percentage of the calculated results.
A.R.I. does not recommend using the Burst Equation.
- If the purpose of the air valve is to protect the system during drainage through a defined drainage valve or at pipe rupture, it is recommended to
use the drainage and rupture analysis based on the orifice equation.

INTRODUCTION
Drainage and Rupture Analyses
Air intake flow rate requirement at drainage through a drain valve or a rupture is:

1. Q d = C d ( D d 2 / 4 ) ( 2 g h) 0 .5
For drains or ruptures whose equivalent diameters are greater than 30% of the pipe diameter:

2. Q d = MC d ( D d 2 / 4 ) ( 2 g h ) 0 .5 a nd M = {1/ [1-(D d / D p ) 4 ]}0.5


Where:

Qd
Cd
Dd
g
h
M
Dp

= Air intake flow rate requirement m2/sec


= Orifice coefficient 0.6 is a common default value
= Drain valve or rupture equivalent diameter - m
= Gravitational acceleration 9.81 m/sec2
= Elevation difference between the air valve and the drain valve or rupture m
= Correction factor
= Diameter of the pipe m

Here, the initial Qd was calculated with no losses. After the initial calculation of Qd , we calculate the Hazen Williams friction head loss, hf due to
this initial Qd:

3. h f = Q d 1. 852 L a ct / ( K 1 .8 5 2 C d 1 .8 5 2 D d 4 .8 7 ) and
L ac t = ( h 1 2 + L h p1 2 ) 0 .5 + ( h 2 2 + L h p2 2 ) 0.5 + (h n 2 +L hp n 2 ) 0.5
Where:

hf
K
L ac t
h 1 , h 2 , h n
L h p 1 , L h p 2 , L hpn

= Hazen Williams friction head loss due to the initial Qd - m


= unit constant = 0.278 for metric units
= Actual total pipe length between the air valve and the drain or rupture m
= Elevation change of each of the pipe segments between the air valve and the drain or rupture - m
= Length of the horizontal projection of each of the pipe segments between the air valve and the drain or rupture - m

Now, we calculate the new h by subtracting hf from the initial h:

4. N e w h = h - h f
Use this New h in either equation 1 or equation 2 above (depending on the size of the drain valve or rupture, relative to the pipe diameter),
and calculate the final Q .
d

Given that the air valve diameter required must be calculated separately for each separate air point in the system, the scope of the calculation work
required is very considerable.
To solve this problem, A.R.I. has developed a unique program ARIavCAD. The ARIavCAD program determines the diameter and the location
for each air valve and selects from the range of valves manufactured by A.R.I., the most appropriate air valve for installation at each point. Use of
the ARIavCAD program is highly recommended. For further details, please contact the A.R.I. Service Department.

INTRODUCTION
Check Valves
One-way or check valves are liquid direction devices that allow one-directional flow in the pipeline.

Check valves have various uses such as:

- Controlling directions of flow of liquid in systems in which there are different sources of supply.
- Preventing reverse flow into pumps when pump operation stops.
- Maintaining down-stream pipe pressure in case of a pressure drop at the supply source.
- Preventing drainage from high to low areas.

There are various types of check valves:

- Swing-type check valves, check valves with top covers, check valves with a tilting disc, dual-leaf check valves, wafer type check valves, spring-loaded
check valves, etc.
All one-directional valves are built from a basic combination of a body (straight or angular) connected to piping and to a one-way sealing mechanism.
The valves are distinguished from one another by the structure of the body and the various sealing mechanisms.
The purpose of the various types of check valves is to provide solutions and adaptations for various applications.
The R&D, engineering and manufacturing divisions of A.R.I. worked together to develop a basket of check valves for a variety of applications. They
meet the needs of designers, installers, users and maintenance personnel.
A.R.I. check valves are adapted for industry, wastewater, desalination, hot water, contaminated water, seawater, agricultural and gardening
applications, potable water, water treatment systems, municipal lines and oil installations on offshore platforms.

Top-cover type check valves are designed to contend with aggressive


environments and solids-laden liquid:

1. The body and cover are cast from a variety of corrosion-resistant materials which cover a wide range of chemicals.
2. The body has a barrel-shaped structure that allows unrestricted flow.
3. A sealing mechanism incorporates a disc that opens fully even under low flow rates and swings up and out of the flow path (full flow). These two
properties:
- enable for the flow of solids-laden liquids without blockage or stagnation, AND
- ensure particularly low head losses (in the range of only a few centimeters), resulting in large energy savings.
4. The top cover provides access for inspection and maintenance without the need for dismantling the valve from the pipeline.
5. The sealing seat assembly is accessible for replacement without dismantling the valve from the line.
6. The internal configuration inhibits cavitation.
7. The shaft that hinges the disc extends from the body of the valve. It serves for mounting counter weights which regulate the closing time of the
disc, and greatly reduce the effects of slam and surge.
8. The enhanced bearing assembly is unique and the shaft sealing is reliable and long-lasting.
9. The hinged arm is connected to the disc by two pins that prevent premature wear of the sealing assembly.
10. A variety of structural materials are used in the sealing mechanism, the disc, and the sealing seat.
11. Interior and exterior coatings are resistant to corrosion, chemicals and to UV.

Typical installation locations:

- In pumping stations for raw wastewater.


- In pumping stations for untreated water.
- In desalination installations.
- In chemical process piping systems to regulate the direction of flow.
- Dividing the pressure between the two ends of long pipe segments in which there are large differences in elevation between the ends.

LOCATION OF AIR VALVES ACCORDING TO PIPE PROFILE AND DIAMETER

D - Combination Air Valve

S - Automatic Air Release Valve

Isolating valve

At peaks

After pressure
reducer

At peaks relative to
hydraulic gardient

At local peaks in
the system

Long lines with


uniform descending slope.
500 - 730 m. between air valves

Long horizontal runs


or long runs parallel
to the hydraulic
gardient about every
500 m.

Change in degree
of up slope

Long desceding slope - about


every 500 m.

Change in degree
of down slope

At ends of horizontal runs or long


runs parallel to the hydraulic gardient

Canal overpass

Before isolating valve

LOCATION OF AIR VALVES ACCORDING TO PIPE PROFILE AND DIAMETER

D - Combination Air Valve

S - Automatic Air Release Valve

Isolating valve

At peaks

After pressure
reducer

At peaks relative to
hydraulic gardient

At local peaks in
the system

Long lines with


uniform descending slope.
500 - 730 m. between air valves

Long horizontal runs


or long runs parallel
to the hydraulic
gardient about every
500 m.

Change in degree
of up slope

Long desceding slope - about


every 500 m.

Change in degree
of down slope

At ends of horizontal runs or long


runs parallel to the hydraulic gardient

Canal overpass

Before isolating valve

WATER SUPPLY

VALVES FOR WATER SUPPLY APPLICATIONS

Water Supply

D-014 / D-015 / D-016

Combination Air Valve for High Pressure

D-040

Combination Air Valve

D-040 LP

Combination Air Valve for Low Pressure

D-090-P

Underground Air Valve System

D-060 LP

Combination Air Valve


for High Flow, Low Pressure

D-060 SB

Underground Air Valve System


for Potable Water

D-060 NS

Combination Air Valve


for High Flow - Non Slam

M-040

D-060 NS M1

D-050

D-060 NS SB

D-050 M1

D-070

D-050 M2

D-070 M1

D-050 LP

D-070-P

D-060

D-070 VB

D-060 M1

K-010 / K-012

Combination Air Valve for Water Meter


Protection Metair

Combination Air Valve

Combination Air Valve

Combination Air Valve

Combination Air Valve


for Low Pressure, Low Pressure

Combination Air Valve for High Flow


EnC-INDXWTR-11 15

Combination Air Valve for High Flow

Combination Air Valve


for High Flow - Non Slam

Underground Air Valve System


for Potable Water

Dynamic Air Valve

Dynamic Air Valve

Dynamic Air Valve

Vacuum Breaker Valve

Air & Vacuum Valve

Water Supply

K-010 M1

GV R 31

K-060

GV NR 31

K-060 NS

RP-500

Air & Vacuum Valve

Air & Vacuum Air Valve for High Flow

Air & Vacuum Air Valve


for High Flow Non Slam

S-014 / S-015 / S-016


Automatic Air Release Valve
for High-Pressure Systems

S-050

Automatic Air Release Valve

S-050 LP

Automatic Air Release Valve for Low Pressure

NR-020

Wafer Style Check Valve

NR-040

Check Valve with Removable Cover

HCCV

Hydraulically Controlled Check Valve

Rising Stem Gate Valve

Non-Rising Stem Gate Valve

Backflow Preventer

DC-500

Backflow Preventer -Double Check Valve

UFR

Unmeasured-Flow Reducer

Air Valve Enclosure


SD-010 GB

Gear Box Driven Horizontal Sliding


Disc Valve

D-014
D-015

PN 40

D-016

PN 64
Water Supply

PN 40

Combination Air Valve for High Pressure


Description

The D-014, D-015, D-016, D-100 series Combination Air Valve


has the features of both an air release valve and an air & vacuum
valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

Municipal and industrial high pressure water conveyance systems.

Operation

EnC-D016WTR-11 17

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing

mechanism to its sealing position.


3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: D-014: 0.2 - 40 bar


D-015: 0.2 - 25 bar / 0.2 - 40 bar / D-016: 0.2 - 64 bar
- Testing Pressure: 1.5 times the working pressure of the air valve.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- Special orifice seat design: combination of bronze and E.P.D.M.
rubber assures long-term maintenance-free operation.
- The discharge outlet enables removal of excess fluids.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosion-resistant
polymer materials.
- Large orifice:
Dramatically reduces the possibility of obstruction by debris.
Releases high air flow rates.
One size orifice for a wide pressure range (up to 64 bar), achieved
by the A.R.I. patented rolling real mechanism

Valve Selection

- The D-014, D-015, D-016 combination air valves are available in


sizes 2, 3 4, 6 8, (10 D-014, D-015 only).
- These valves are manufactured with flanged ends to meet any
requested standard.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The automatic air release component and the air & vacuum
component are available as separate units.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-014 / D-015 / D-016

D-014 DIMENSIONS AND WEIGHT


Nominal

Dimensions mm

Size

Connections

Weight

1 BSP Female 1/2 BSP Female

23.0

2 (50mm) Threaded

330

483

Nominal

Dimensions mm

Size

internal

Orifice Area mm2

Kg.

Connection
external

Weight
Kg.

A/V

Auto.

794

15

Orifice Area mm2


A/V

Auto.

3 (80mm)

331

513

63.5

74.4

1/2 BSP Female

29.5

1809

15

4 (100mm)

386

529

80

98

1/2 BSP Female

37.5

2463

15

6 (150mm)

583

719

124

140

1/2 BSP Female

90.0

17662

15

8 (200mm)

577

704

124

140

1/2 BSP Female

129.0

17662

15

Nominal

Dimensions mm

Size

10" (250mm)

481

845

Connection

Weight

1/2 BSP Female

149.0

Kg.

Orifice Area mm2


A/V

Auto.

31400

15

D-016

D-014

3 - 8

3 - 8

D-016 DIMENSIONS AND WEIGHT


Nominal
Size

Dimensions mm
B

internal

Connection
external

Weight
Kg.

Orifice Area mm2


A/V

Auto.

2 (50mm)

330

483

54

60

1/2 BSP Female

23.0

794

15

3 (80mm)

450

545

81

89

1/2 BSP Female

29.5

1809

15

4 (100mm)

469

587

81

89

1/2 BSP Female

37.5

2463

15

6 (150mm)

583

719

108

124

1/2 BSP Female

90.0

17662

15

8 (200mm)

577

704

108

124

1/2 BSP Female

129.0

17662

15

10

D-014 / D-016
A

PARTS LIST AND SPECIFICATION 2"-4"


No.

Part

1.

Orifice Cover

Polypropylene

2.

Nut

Brass ASTM B-124

3.

O-Ring

BUNA-N

4.

Orifice

Reinforced Nylon

5.

Pin

Stainless Steel SAE 304

6.

Rolling Seal

E.P.D.M.

7.

Lever

Reinforced Nylon

8.

Cover

Cast Steel ASTM A216 WCB

9.

O-Ring

BUNA-N

10.

Bolt, Nut & Washer

Steel Zinc Cobalt Plated

10

11.

Float

Polycarbonate

12.

Body

Cast Steel ASTM A216 WCB

13.

Adapter

Brass ASTM B124

14.

Cover

Cast Steel ASTM A216 WCB

15.

Bolt, Nut & Washer

Steel Zinc Cobalt Plated

16.

Orifice Seat

Bronze ASTM B62 B271 C83600

17.

Orifice Seal

E.P.D.M.

18.

O-Ring

BUNA-N

19.

Float

Polycarbonate / Stainless Steel SAE 316

20.

Body

Cast Steel ASTM A216 WCB

/ Stainless Steel SAE 316

2
3

4
5
6
7

11
12
13
14
15
16

17
18
19
20

PARTS LIST AND SPECIFICATION 6", 8"


No.

Part

Material

1.

Adapter

Brass ASTM B124

2.

Float

Polycarbonate / Stainless Steel SAE 316

3.

Body

Cast Steel ASTM A216 WCB

4.

O-Ring

BUNA-N

5.

Rollpin

Stainless Steel SAE 304

6.

Orifice

Reinforced Nylon

7.

O-Ring

BUNA-N

8.

Nut

Brass ASTM B-124

9.

13

12

11

10

EnC-D016WTR-11 19

Orifice Cover

Polypropylene

10.

Rolling Seal

E.P.D.M.

11.

Lever

Reinforced Nylon

12.

Cover

Cast Steel ASTM A216 WCB

13.

Bolt, Nut & Washer

Steel Zinc Cobalt Plated

14.

Protective Cover

Cast Iron ASTM A48CC35B

15.

Cover

PN 40

Cast Steel ASTM A216 WCB

PN 64

Cast Steel ASTM A148 115-95

16

C
14
15

16.

O-Ring

BUNA-N

17

17.

O-Ring

BUNA-N

18

18.

Orifice Seat

Bronze ASTM B62 B271 C83600

19

19.

Orifice Seal

E.P.D.M.

20.

Body

Cast Steel ASTM A216 WCB

20

21.

Float

22.

6"

Polycarbonate / Stainless Steel SAE 316

8"

Stainless Steel SAE 316

Bolt, Nut & Washer

Steel Zinc Cobalt Plated

21
22

D-015
DIMENSIONS AND WEIGHT
Nominal

Dimensions mm

Size

Connections

Weight

2 (50mm) Threaded

213

484

1 BSP Female

1/2 BSP Female

2 (50mm) Flanged

213

487

1 BSP Female

1/2 BSP Female

Nominal
Size

Dimensions mm

internal

Orifice Area mm2

Kg.

A/V

Auto.

15.4

794

15

16.4

794

15

Connection
external

Weight

74.6

1/2 BSP Female

21.9

Kg.

Orifice Area mm2


A/V

Auto.

1809

15

3 (80mm)

313

515

63.5

4 (100mm)

369

535

80.0

96.0

1/2 BSP Female

40.0

3317

15

6 (150mm)

559

679

124.0

140.0

1/2 BSP Female

82.4

17662

15

8 (200 mm)

559

679

124.0

140.0

1/2 BSP Female

121.4

17662

15

Connection

Weight

1/2 BSP Female

132.4

Nominal
Size

Dimensions mm

10" (250mm)

463

866

Kg.

Orifice Area mm2


A/V

Auto.

31400

15

PARTS LIST AND SPECIFICATION


No.
1.

Part

Material

Discharge Outlet

PVC

2.

Rollpin

Stainless Steel SAE 304

3.

O-RING

BUNA-N

4.

Orifice

Reinforced Nylon

5.

Cover

Ductile Iron ASTM A536 60-40-18

6.

Rollpin

Stainless Steel SAE 304

7.

Rolling Seal

E.P.D.M.

8.

Lever

Reinforced Nylon

9.

Rollpin

Stainless Steel SAE 304

10.

O-Ring

BUNA-N

11.

Bolt, Nut &

Steel, Zinc Cobalt Plated

1
2

3
4
5
6
7
8
9
10
11

Washer

12

12.

Float

Polycarbonate / Stainless Steel SAE 316

13.

Body

Ductile Iron ASTM A536 60-40-18

14.

Adapter

Brass ASTM B124

14

15.

Orifice Seat

Bronze ASTM B-62 B271 C83600

15

16.

Orifice Seal

E.P.D.M.

16

17.

Cover

Ductile Iron ASTM A-536-60-40-18

18.

O-Ring

BUNA-N

19.

Bolt, Nut &

Steel Zinc Cobalt Plated

13

Washer
20.

Float

Polycarbonate / Stainless Steel 304L

21.

Body

Ductile Iron ASTM A-536-60-40-18

Screen Cover 10

Polyethylene

17
18
19
20
21

/Cast Iron ASTM A-48 CL35B


/Ductile Iron ASTM A-536-60-40-18
A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988
A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-040
D-040-C

PN 16

Water Supply

PN 16

Combination Air Valve


Description

The D-040 series Combination Air Valve has the features of both an
air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Pump stations: after the pump and after the check valve.
- Downstream (after) and upstream (before) of shut-off valves.
- After deep-well pumps.
- On long constant-sloped pipeline segments.
- At peaks along the pipeline and at peaks relative to hydraulic
gradient.
- At end lines.
- Before water meters.
- On strainers and filters.
D-040-C - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.

Operation

EnC-D040WTR-11 21

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float, which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a

partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.2 - 16 bar


- Testing pressure: 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- The drainage outlet enables removal of excess fluids.
- The large size of the automatic air release orifice relative to the air
valve body:
Discharges air at high flow rates.
Lessens the danger of its obstruction by debris.
Enables the usage of the patented rolling seal mechanism, making
it less sensitive to pressure differential than a direct float seal.
- The body is made of high-strength composite materials and all

D-040
operating parts are made of specially selected, corrosion- resistant
materials.
- Due to its light weight, the valve may be installed on plastic piping
systems, as well as other lightweight piping systems.
- D-040-C the body is protected in a metal shell for anti-vandalism/
theft applications.

Valve Selection

The air valve is available with:


- Wide size range: 1/2, 3/4, 1, 2 threaded male connections,
NPT or BSPT.
- Optional ball valve tap; BSPT or NPT male connection.

Options

- The D-040 air valve is available in the following options:


D-040 1 & 2 - reinforced nylon body and base.
D-040 B 1 & 2 -reinforced nylon body and brass base.
D-040 C 1 & 2 - cast iron shell and base (1 base - brass)
D-040 ST. - reinforced nylon body and stainless steel base.
D-040 ST ST - stainless steel body and stainless steel base.
- The D-040 LP air valve is made for very low pressure systems with
a maximum working pressure of PN 6.
- The DG-10 air valve is made for low pressure systems with a
maximum working pressure of PN10.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-040
ACCESSORIES
Ball Valve
Shut-off valve: Made of brass ATSM B-124
Suitable for: D-040 1 2
D-040-C 1 2
Flanges
Made of reinforced nylon / cast ductile / st. 37
Suitable for: D-040 1 2

D-040-C T 2

D-040 P T 2

D-040-C 1 2

D-040 P T 1

Diameter 40/50/60 Internal threads: 3/4, 1, 2


Diameter 40/50/65 Internal threads: 3/4 1 2

D-040-C T 1

Diameter 50mm Internal threads: 1 2


Diameter 80mm Internal threads: 2 3

Thermal frotection Jacket


Made of polyurethane

Extension
Available with extended pipe.

One-way models
The D-040 series air valve is available as:
D040-V -With a one-way, out-only attachment, allows air discharge
only, prevents air intake (all models).
D-040-I -With a vacuum breaker, in-only attachment, allows air
intake only, not allowing air discharge (D-040 2 only).
D-040-NS -With a non-slam, discharge-throttling attachment, allows full air intake, throttles air discharge (D-040 2 only).

D-040-NS 2

D-040 Non-Slam Single Orifice Add-on Component Data Table

EnC-D040WTR-11 23

Model

Nominal
Size

Discharge
orifice

Total NS
area

NS orifice

Switching
point

Flow at
0.4 bar

D-040 NS

2 (50mm)

37.5 mm

12.6 mm2

4 mm

Spring loaded
normally closed

17.5 m3/h

D-040

D-040 1"

D-040 2"

D-040 B 2"

D-040 ST 2"

D-040 ST ST 2"

DIMENSIONS AND WEIGHTS


Model

Dimensions mm
A

Connection
C

Weight
Kg.

Orifice Area mm2


Auto.

A/V

1/2 3/4 1
D-040

100

143

3/8 BSP Female

0.33

7.8

100

D-040 B

100

143

3/8 BSP Female

0.70

7.8

100

D-040 ST

100

143

3/8 BSP Female

0.65

7.8

100

D-040 ST ST

100

143

3/8 BSP Female

1.40

7.8

100

D-040 P

183

215

1 BSP Female

1.10

12

804

D-040 B

183

215

1 BSP Female

1.80

12

804

D-040 ST

183

215

1 BSP Female

2.10

12

804

D-040 ST ST

183

215

1 BSP Female

3.10

12

804

2
3

6
7

PARTS LIST AND SPECIFICATION


No.

Part

Material
D-040 / B / ST

Material
D-040 ST ST

1.

Body

Reinforced Nylon

St.St. SAE 316

2.

Discharge Outlet

Polypropylene

Polypropylene

3.

1/2 3/4 1 Rolling Seal

E.P.D.M.

A
3

Viton / BUNA-N / E.P.D.M.

2 Rolling Seal Assembly:


3a. Screws

Stainless Steel

Stainless Steel

3b. Plug Cover

Reinforced Nylon

Polypropylene / R.N.

3c. Rolling Seal

E.P.D.M.

Viton / BUNA-N / E.P.D.M.

3d. Plug

Reinforced Nylon

Polypropylene / R.N.

4.

Clamping Stem

Reinforced Nylon

Polypropylene / R.N.

5.

Float

Foamed Polypropylene Foamed Polypropylene

6.

O-Ring

BUNA-N

BUNA-N

7.

Base

Reinforced Nylon

St.St. SAE 316

5
6
7

/ Brass ASTM B124


/ St.St. SAE 316
Optional Ball valve

3c

3b

3a

Brass ASTM-B-124,
Nickel plated.

3d

D-040-C

D-040-C 1"

D-040-C 2"

D-040-C F 2"

DIMENSIONS AND WEIGHTS


Model

Dimensions mm

Connection

125

150

3/8 BSP Female

D-040-C

203

230

D-040-C F

214

230

Weight
Kg.

Orifice Area mm2


Auto.

A/V

1.2

82

1 BSP Female

5.4

12

804

1 BSP Female

7.3

12

804

1/2 3/4 1
D-040-C

2
3

4
5
6
7
8

PARTS LIST AND SPECIFICATION


N0.

Part

Material

1.

Shell

Cast Iron ASTM A48 CL.35B

2.

Body

Reinforced Nylon

3.

1/2 3/4 1 Rolling Seal

3.

E.P.D.M.

2 Rolling Seal Assembly

EnC-D040WTR-11 25

3a.

Screws

Stainless Steel

3b.

Plug Cover

Reinforced Nylon

3c.

Rolling Seal

3d.

Plug

Reinforced Nylon

4.

Discharge Outlet

Polypropylene

5.

Clamping Stem

Reinforced Nylon

6.

Float

Foamed Polypropylene

7.

O - Ring

Buna-N

8.

Base 1/2 3/4 1

Brass

2
9.

Bolt & Nut (x4)

Optional Ball valve

E.P.D.M.

Cast Iron ASTM A48 CL.35B


Steel Zinc Cobalt Coated
Brass ASTM-B-124, Nickel plated.

8
9

3c

3b

3a

3d

D-040

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-040 LP

Water Supply

PN 6

Combination Air Valve for Low Pressure


What is a low pressure air valve?

The low pressure air valve sealing mechanism is built with a very
soft and sensitive seal. On one hand, it enables the full and effective
discharge of air and, on the other hand, the air valve will close and
seal tightly when water fills the valve, even if the water pressure is
particularly low. Most other air valves are built so that it takes a
higher minimum sealing pressure to effectively seal the valve. The
A.R.I. air valve requires a minimum water pressure of just 0.2 bar to
effectively seal. Low pressure air valves are designed to prevent water
leaks through the discharge orifice of the air valve.

Description

The D-040 LP series Combination Air Valve has the features of


both an air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

The D-040 LP is designed for installation on:


1. Outlets from storage ponds and reservoirs.
2. Topographic high points where water pressures are lower than 2
meters.
3. Points on a pipeline of variable pressures, where pressures can
drop below 2 meters.
4. Topographical points on a pipeline that are close to the hydraulic
grade line pressure.
5. The top of water tanks

EnC-D040LPWTR-11 27

Operation

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float, which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused

by water column separation. Air entry is essential to efficiently drain


the system. The air release component releases entrapped air in
pressurized systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances: :
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.05 - 6 bar.


- Testing pressure: 10 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- The drainage outlet enables removal of excess fluids.
- The large size of the automatic air release orifice relative to the air
valve body:
Discharges air at high flow rates.

D-040 LP
Valve Selection

Lessens the danger of its obstruction by debris.


Enables the usage of the patented rolling seal mechanism, making
it less sensitive to pressure differentials than a direct float seal.
- The body is made of high-strength composite materials and all
operating parts are made of specially selected, corrosion- resistant
materials.
- Due to its light weight, the valve may be installed on plastic piping
systems, as well as other lightweight piping systems.

- Diameter: 2
The air valve is available with:
- NPT or BSPT threaded male connections,
- Optional ball valve tap;, BSPT or NPT male connection.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

DIMENSIONS AND WEIGHTS


Nominal
Size

Dimensions mm

183

215

Connection

Weight

1 BSP Female

1.1

Kg.

Orifice Area mm2


Auto.

A/V

12

804

PARTS LIST AND SPECIFICATION


No. Part

Material

1.

Body

Polypropylene / Reinforced Nylon

2.

Discharge Outlet

Polypropylene

3.

A
1

2 Rolling Seal Assembly:

3a.

Screws

Stainless Steel

3b.

Plug Cover

Reinforced Nylon / Polypropylene

3c.

Rolling Seal

Silicone

3d.

Plug

Reinforced Nylon / Polypropylene

4.

Clamping Stem

Reinforced Nylon / Polypropylene

5.

Float

Foamed Polypropylene

6.

O-Ring

BUNA-N

7.

Base

Polypropylene / Reinforced Nylon

4
5

C
3c

3b

3a

6
7

3d

Optional
Ball valve

Brass ASTM-B-124, Nickel plated

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-090-P

Water Supply

PN 16

Underground Air Valve System


Description

The D-090-P Underground Air Valve is designed to save the costs


of manholes and provide reliable solutions for special requirements
such as:
- Frost protection.
- Savings in installation costs.
- Installation under important crossings, including: roads,
pavements, buildings.
- Eliminate the need for confined-space entry - its costs and safety
demands.

Operation

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The automatic air release component releases entrapped air in
pressurized systems.

EnC-D090PWTR-11 29

Without air valves, pockets of accumulated air may cause the


following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing

mechanism to its sealing position.


3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure:
D-090-P with the DG-10 0.1 - 10 bar
D-090-P with the D-040 0.2 - 16 bar
- Maximum working temperature: 600 C.
- Maximum intermittent temperature: 900 C.
- Materials: the air valve is made of corrosion-resistant materials.
- Integral check valve: shuts automatically when removing the air
valve for maintenance purposes.
- Drainage System: A special one-way outlet drains the water from
the valve box and prevents water intake.
- Dynamic design allows high velocity air discharge, prevents
premature closing.
- A.R.I. patented rolling Seal Mechanism:
Dramatically reduces obstruction by debris.
The automatic function discharges high air flow rates of up
to 160 m3/h.
Self - cleaning mechanism.
- Low maintenance costs.
- Air valve box made of P.V.C. according to high-quality standard.
- Lightweight and compact silhouette.

Valve Selection

- Connections: threaded 2", flanged 2", 3", 4" to meet any


requested standard.
- Eight different installation lengths: 500 mm, 755 mm, 1055 mm,
1305 mm, 1555mm, 1830mm, 2135mm, 2440mm.

Options

- D-090-P LP: for low pressure


- Internal frost protection.

D-090-P

DIMENSIONS AND WEIGHT


Dimensions mm

Weight Kg.

Aluminium B.

500

195

5.8

755

195

7.3

8.5

1055

195

8.9

9.8

1305

195

9.9

11.2

1555

195

11.1

12.3

1830

195

12.4

13.6

2135

195

13.7

14.9

2440

195

15

16.3

Ductile Iron B.

1
2

PARTS LIST AND SPECIFICATION

6
7

No. Part

Material

1. Cover

Polypropylene

8
9

2. Air Valve Box

P.V.C.

3. Insulation Cover

Aluminum Coated Foamed PE

4. Bridge Assembly

Reinforced Nylon

5. Tightening Rod

Stainless Steel SAE 304

11
12

6. Lock Pin

Stainless Steel SAE 304

7. Check Valve (D-090-P V)*

Acetal / NBR / St. St.

8. D-040 Cover

Reinforced Nylon

9. Rolling Seal Assembly

ST.ST + R.N + E.P.D.M.

10. O-Ring (D-090-P V)* BUNA-N

10

13
14
15

11. Clamping Stem

Reinforced Nylon

12. Lock Pin

Stainless Steel SAE 304

13. Float

Foamed Polypropylene

17
18

14. D-040 Body

Reinforced Nylon

15. D-040 Base

Reinforced Nylon

16. O-Ring

BUNA-N

17. Base

Ductile Iron / Aluminum

18. Drainage Connector

Polypropylene + Acetal

19. Check valve

Acetal / NBR / St. St.

20. Adaptor

Stainless Steel SAE 316

* Optional -upon request

16

19
20

D-090-P
APPLICATIONS / ACCESSORIES

One-Way Options
- One-way attachment for discharge of air only, not allowing for
air intake.
- One-way attachment for intake of air only, not allowing for air
discharge.
- Non-Slam discharge-throttling attachment, allows full air intake,
throttles air discharge.

Internal Frost Protection Element

Service Tap
This stand pipe system is installed for the following purposes:
- Extracting water from the line (sampling, cleaning purposes etc).
- Cleaning of the line itself.
- Releasing large quantities of air from the line manually.

EnC-D090PWTR-11 31

D-090-P
Sample Installation Scheme

Important Information: Prior to site preparation and installation,


please refer to the D-090-P Installation and Maintenance Manual
for all the relevant instructions and information. The manual can be
obtained by contacting the A.R.I marketing dept., from your local
A.R.I. distributor or downloading the file from our website.

M-040

Water Supply

PN 10

Combination Air Valve for Water Meter Protection Metair


Description

The M-040 Combination Air Valve combines an air & vacuum


orifice with an automatic air release orifice in one single body.
The combination air valve discharges air during the filling of the
system and admits air during drainage and pump shutoff while
releasing accumulated air from the system while the system is
operating under pressure.
The M-040 Combination Air Valve is designed to prevent problems
caused by discontinuous or erratic water supply:
- Erroneous water metering.
- Damage to the spinning components of the water meter.
- Vibrations and water hammer in the pipeline and water meter.

Applications

- On a pressurized piping system, installed before the water meter.

Operation

EnC-M040WTR-11 33

OVERVIEW: The M-040 combination air valve is normally closed.


When water supply is erratic and air builds up in the system, the
M-040 prevents the air from passing through the water meter by
releasing this accumulated air from the pipeline to the atmosphere.
As water returns, it buoys the float, sealing the outlet to the
atmosphere, opening the check valve and allowing the water to pass
through water meter.
The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The automatic small orifice air release component releases entrapped
air in pressurized systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.

- Obstruction of efficient hydraulic transmission due to air flow


disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
and air release orifices.
2. Air will enter the system.

Main Features

- Working range: 0.2 - 10 bar


- Testing pressure: 16 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Lightweight and small, made of corrosive-resistant composite
materials.
- Spring-loaded check valve opens at 0.25 bar water pressure in the
direction of the water meter. The check valve assures effective air
trapping and prevents water drainage from the water meter.
- User-friendly integral shutoff valve: an innovative built- in shut
off valve in the valve cap enables the isolation of the air valve orifice
with no interference to the water flow in the pipeline.
- Drainage System: Optional drainage outlet or screen outlet.
- The large orifice, with its self-cleaning mechanism, dramatically
reduces obstruction due to debris.
- Integral air trapping non-return valve.
- Dynamic design allows high velocity air discharge while preventing
premature closure

M-040
- Maintenance free.

Valve Selection

- Connections: M/F threaded 1/2, 3/4 BSPT or NPT


- Optional One-Way Out addition, allows air discharge only,
prevents air intake.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

DIMENSIONS AND WEIGHT


Dimensions mm

84

122

11

Weight
Kg.

Orifice Area mm2


Auto.

A/V

5.6

42

0.3

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Cover

Acetal

2.

Discharge Outlet

Acetal

3.

Plug

E.P.D.M.

4.

O-Ring

BUNA-N

5.

Seat

Polypropylene

6.

Seal

E.P.D.M

7.

Float

Foamed Polypropylene

8.

Body

Polypropylene

9.

O-Ring (x2)

BUNA-N

10.

Base

Brass CW617 N

11.

Spring

Stainless Steel SAE 302

12.

Valve Stopper

Acetal

13.

Valve Stem

Acetal

14.

O-Ring

BUNA-N
A
1

2
3
4
5
6

7
8
9
10
11
12
13
14

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-050
D-050-C
D-052

PN 16
Water Supply

PN16

PN25

Combination Air Valve


Description

The D-050 Combination Air Valve has the features of both an air
release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.


D-050-C D-052 - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.

Operation

EnC-D050WTR-11 35

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.

- Accelerate cavitation damages.


- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range:



D-050, D-050-C 0.2 - 16 bar

D-052 0.2 - 25 bar
- Testing Pressure: 1.5 times the working pressure of the air valve.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- Special orifice seat design: combination of bronze and E.P.D.M.
rubber assures long-term maintenance-free operation.
- The discharge outlet enables removal of excess fluids (2" - 8").
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosion-

D-050
resistant polymer materials.
- Large sized air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 25 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Valve Selection

- Size range 2 12.


- D-050 is made for 16 bars.
- D-050-C vandalism protected by a metal shell covering the air
release component, made for 16 bar.
- D-052 vandalism protected by a metal shell covering the air release
component, made for 25 bar.
- These valves are manufactured with flanged ends to meet any
requested standard.
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The automatic air release component and the air & vacuum
component are available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-050
DIMENSIONS AND WEIGHT
Nominal

Dimensions mm

Size

Connections

Weight

2 (50mm) Threaded

167

330

1 BSP Female

1/8 BSP Female

2 (50mm) Flanged

170

336

1 BSP Female

1/8 BSP Female

Nominal
Size

Dimensions mm
B

internal

Kg.

382

80.0

96.0

1/8 BSP Female

553

550

124.0

140.0

1/8 BSP Female

8 (200 mm)

553

554

124.0

140.0

1/8 BSP Female

Connection

Weight

463

718

1/8 BSP Female

12 (300mm)

586

846

1/8 BSP Female

794

12

18.4

342

10 (250mm)

12.4

6 (150mm)

12

1/8 BSP Female

4 (100mm)

794

74.6

63.5

9.4

external

365

Size

Auto.

Weight

286

Dimensions mm

A/V

Connection

3 (80mm)

Nominal

Orifice Area mm2

Kg.

Orifice Area mm2

Kg.

A/V

Auto.

1809

12

26.4

3317

12

76.6

17662

12

117

17662

12

Orifice Area mm2


A/V

Auto.

150

31400

12

162

49087

12

PARTS LIST AND SPECIFICATION

EnC-D050WTR-11 37

No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M.

4. Float

Foamed Polypropylene

5. Clamping Stem

Reinforced Nylon

6. O-Ring

BUNA-N

7. Base

Brass ASTM B124

8. Strainer

Nylon

9. Orifice Seat

Bronze ASTM B-62 B271 C83600

10. Orifice Seal

E.P.D.M.

11. Cover

Ductile Iron ASTM A-536-60-40-18

12. O-Ring

BUNA-N

13. Bolt, Nut & Washer

Steel Zinc Cobalt Plated

14. Float

Polycarbonate / Stainless Steel

15. Body

Ductile Iron ASTM A-536-60-40-18

* Screen Cover 10-12

Polyethylene

/Cast Iron ASTM A-48 CL35B

/Ductile Iron ASTM A-536-60-40-18

1
2

6
7

B
C

8
9
10
11
12
13
14
15

D-050-C / D-052
DIMENSIONS AND WEIGHT
Nominal

Dimensions mm

Size

Connections

Weight

2 (50mm) Threaded

173

340

1 BSP Female

1/8 BSP Female

2 (50mm) Flanged

173

346

1 BSP Female

1/8 BSP Female

Nominal
Size

Dimensions mm
B

internal

Kg.

Orifice Area mm2


A/V

Auto.

10.0

794

12

13.0

794

12

Connection
external

Weight

74.6

1/8 BSP Female

19.3

Kg.

Orifice Area mm2


A/V

Auto.

1809

12

3 (80mm)

286

368

63.5

4 (100mm)

342

393

80.0

96.0

1/8 BSP Female

27.4

3317

12

6 (150mm)

553

558

124.0

140.0

1/8 BSP Female

79.0

17662

12

8 (200 mm)

553

560

124.0

140.0

1/8 BSP Female

118.0

17662

12

Nominal

Dimensions mm

Size

Connection

Weight

Kg.

Orifice Area mm2

A/V

Auto.

10 (250mm)

463

724

1/8 BSP Female

151.0

31400

12

12 (300mm)

586

853

1/8 BSP Female

163.0

49087

12

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Shell

Cast Iron ASTM A-48 CL35B

D-050-C

1
2

D-050-C, D-052

Ductile Iron ASTM A-536-60-40-18

2. Body

Reinforced Nylon

3. Discharge Outlet

Brass ASTM B-124

4. Rolling Seal

E.P.D.M.

5. Float

Foamed Polypropylene

6. Clamping Stem

Reinforced Nylon

7. O-Ring

BUNA-N

8. Base

Brass ASTM B124

9. Strainer

Nylon

10. Orifice Seat

Bronze ASTM B-62 B271 C83600

11. Orifice Seal

E.P.D.M.

11

12. Cover

Ductile Iron ASTM A-536-60-40-18

13. O-Ring

BUNA-N

12

14. Bolt, Nut & Washer

Steel Zinc Cobalt Plated

15. Float

Polycarbonate / Stainless Steel 304L

14

16. Body

Ductile Iron ASTM A-536-60-40-18

15

* Screen Cover 10 12

Polyethylene

/Cast Iron ASTM A-48 CL35B

16

/Ductile Iron ASTM A-536-60-40-18

9
10

13

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-050 M1
D-050-C M1
D-052 M1

PN 16

Water Supply

PN 16

PN 25

Combination Air Valve


Description

The D-050 M1 Combination Air Valve has the features of both an


air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.


D-050-C M1 D-052 M1 - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.

Operation

EnC-D050M1WTR-11 39

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.

- Accelerate cavitation damages.


- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: D-050 M1 0.2 - 16 bar,



D-050-C M1 0.2-16 bar,

D-052 M1 0.2-25 bar.
- Testing Pressure: 1.5 times the working pressure of the air valve.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- Special orifice seat design: combination of bronze and E.P.D.M.
rubber assures long-term maintenance-free operation.
- The discharge outlet enables removal of excess fluids.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosion-

D-050 M1
resistant polymer materials.
- Large sized air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 25 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Valve Selection

- Size range 2", 3", 6".


- D-050 M1 for 16 bar.
- D-050-C M1 vandalism protected by a metal shell covering the air
release component, made for 16 bar.
- D-052 M1 vandalism protected by a metal shell covering the air
release component, made for 25 bar.
- These valves are manufactured with flanged ends to meet any
requested standard.
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The air release component and the air & vacuum component are
available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-050 M1
DIMENSIONS AND WEIGHTS
Nominal

Dimensions mm

Size

2 (50mm) Threaded

Connections

Weight

Kg.

173

293

1 BSP Female

1/8 BSP Female

4.3

Orifice Area mm2


A/V

Auto.

794

12

2 (50mm) Flanged

173

306

1 BSP Female

1/8 BSP Female

6.4

794

12

3 (80mm) Threaded

184.3

329

2 BSP Female

1/8 BSP Female

10

1809

12

3 (80mm) Flanged

211

328

2 BSP Female

1/8 BSP Female

13

1809

12

Nominal
Size

6 (150mm)

Dimensions mm

A
399

internal

432

90

Connection
external

Weight

106

1/8 BSP Female

43.5

Kg.

Orifice Area mm2


A/V

Auto.

7850

12

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Body

Reinforced Nylon

2.

Discharge Outlet

Polypropylene

3.

Rolling Seal

E.P.D.M.

4.

Clamping Stem

Reinforced Nylon

5.

Float

Foamed Polypropylene

6.

O-Ring

BUNA-N

7.

Base

2", 3"
6"

Reinforced Nylon
Brass ASTM B-124

8.

Strainer

Nylon

9.

Cover

Ductile Iron ASTM A-536 60-40-18

10.

Orifice Seat

Bronze

11.

Orifice Seal

E.P.D.M.

12.

O-Ring

BUNA-N

13.

Bolt, Nut & Washer

Steel, Zinc Cobalt coated

14.

Body

Ductile Iron ASTM A-536 60-40-18

15.

Float

Polycarbonate / Stainless Steel SAE 316

3
4
5
6

10

11
12
13
14
EnC-D050M1WTR-11 41

15

D-050-C M1 / D-052 M1
DIMENSIONS AND WEIGHTS
Nominal

Dimensions mm

Size

Connections

Weight

2 (50mm) Threaded

168

302

1 BSP Female

1/8 BSP Female

2 (50mm) Flanged

168

315

1 BSP Female

1/8 BSP Female

7.8

794

12

3 (80mm) Threaded

182

336.5

2 BSP Female

1/8 BSP Female

11.5

1809

12

3 (80mm) Flanged

205

339

2 BSP Female

1/8 BSP Female

14.4

1809

12

Nominal
Size

6 (150mm)

Dimensions mm

399

internal

439

90

Kg.

Orifice Area mm2

5.7

Connection
external

Weight

106

1/8 BSP Female

44.9

Kg.

A/V

Auto.

794

12

Orifice Area mm2


A/V

Auto.

7850

12

PARTS LIST AND SPECIFICATION


No

Part

1.

Shell
D-050-C M1

Material

2
3
4

Cast Iron ASTM A-48 CL35B

D-050-C M1, D-052 M1 Ductile Iron ASTM A-536 60-40-18

2.

Body

Reinforced Nylon

3.

Discharge Outlet

Brass ASTM B-124

4.

Rolling Seal

E.P.D.M.

5.

Float

Foamed Polypropylene

6.

Clamping Stem

Reinforced Nylon

7.

O-Ring

BUNA-N

8.

Base

Brass ASTM B124

9.

Strainer

Nylon

10.

Cover

Ductile Iron ASTM A-536 60-40-18

13

11.

Orifice Seat

Bronze

14

12.

Orifice Seal

E.P.D.M

13.

O-Ring

BUNA-N

15

14.

Bolt, Nut & Washer

Steel, Zinc Cobalt coated

15.

Body

Ductile Iron ASTM A-536 60-40-18

16.

Float

Polycarbonate / Stainless steel SAE 316

7
8

10

11
12

16

A
A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988
A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-050 M2
D-050-C M2
D-052 M2

PN 16

Water Supply

PN 16

PN 25

Combination Air Valve


Description

The D-050 M2 series Combination Air Valve has the features of


both an air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.


D-050-C M2 D-052 M2 - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.

Operation

EnC-D050M1WTR-11 43

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow

disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range:


D-050 M2, D-050-C M2 0.2 - 16 bar
D-052 M2 0.2 - 25 bar
- Testing Pressure: 1.5 times the working pressure of the air valve.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- Special orifice seat design: combination of bronze and E.P.D.M.
rubber assures long-term maintenance-free operation.
- The discharge outlet enables removal of excess fluids.

D-050 M2
Automatic component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 25 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Valve Selection

- Size range 4, 6, 8, 12.


- D-050 M2, made for 16 bar.
- D-050-C M2 vandalism protected by a metal shell covering the air
release component, made for 16 bar.
- D-052 M2 vandalism protected by a metal shell covering the air
release component, made for 25 bar.
- These valves are manufactured with flanged ends to meet any
requested standard.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The automatic air release component and the air & vacuum
component are available as separate unit.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-050 M2
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm
B

internal

Connection
external

Weight

74.6

1/8 BSP Female

Kg.

Orifice Area mm2


A/V

Auto.

20.8

1809

12

4 (100mm)

295

365

63.5

6 (150mm)

371

382

80.0

96.0

1/8 BSP Female

34.5

3317

12

8 (200mm)

418

432

90.0

106.0

1/8 BSP Female

43.6

7850

12

12 (300mm)

463

780

124.0

140.0

1/8 BSP Female

160.0

31400

12

PARTS LIST AND SPECIFICATION

No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

Rubber E.P.D.M

4. Float

Foamed Polypropylene

5. Clamping Stem

Reinforced Nylon

6. O-Ring

BUNA-N

7. Base

Brass ASTM B124

8. Strainer

Nylon

9. Orifice Seat

Bronze ASTM B-62 B271 C83600

10. Orifice Seal

E.P.D.M.

11. Cover

Ductile Iron ASTM A-536 60-40-18

11

12. O-Ring

BUNA-N

12

13. Bolt, Nut & Washer

Steel Zinc Cobalt Plated

14. Float

Polycarbonate / Stainless Steel

13

15. Body

Ductile Iron ASTM A-536 60-40-18

* Screen Cover 12

Polyethylene

/Cast Iron ASTM A-48 CL35B

/Ductile Iron ASTM A-536 60-40-18

4
5

9
10

14
15

EnC-D050M1WTR-11 45

D-050-C M2 / D-052 M2
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm
B

internal

Connection
external

Weight

74.6

1/8 BSP Female

Kg.

Orifice Area mm2


A/V

Auto.

21.7

1809

4 (100mm)

300

368

63.5

6 (150mm)

371

382

80.0

96.0

1/8 BSP Female

30.7

3317

8 (200mm)

418

439

90.0

106.0

1/8 BSP Female

44.5

7850

12 (300mm)

586

785

124.0

140.0

1/8 BSP Female

140

17662

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Shell D-050-C-M2

Cast Iron ASTM A-48 CL35B

Ductile Iron ASTM A-536 60-40-18

D-052-M2

2. Body

Reinforced Nylon

1
2

3
4

3. Discharge Outlet

Brass ASTM B-124

4. Rolling Seal

E.P.D.M.

5. Float

Foamed Polypropylene

6. Clamping Stem

Reinforced Nylon

7
8

7. O-Ring

BUNA-N

8. Base

Brass ASTM B124

9. Strainer

Nylon

10. Orifice Seat

Bronze ASTM B-62 B271 C83600

11. Orifice Seal

E.P.D.M.

12. Cover

Ductile Iron ASTM A-536 60-40-18

13. O-Ring

BUNA-N

14. Bolt, Nut & Washer

Steel Zinc Cobalt Plated

5
6

10
11
12
13

15. Float

Polycarbonate / Stainless Steel

14

16. Body

Ductile Iron ASTM A-536 60-40-18

* Screen Cover

Polyethylene

15

12

/Cast Iron ASTM A-48 CL35B

/Ductile Iron ASTM A-536 60-40-18

16

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-050 LP

Water Supply

PN 6

Combination Air Valve for Low Pressure


Description

The D-050 LP Combination Air Valve has the features of both an


air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.


- Low pressure systems.

Operation

EnC-D050LPWTR-11 47

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.

As the system starts to fill, the valve functions according to the


following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.05 - 6 bar


- Testing pressure: 10 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- Special orifice seat design: combination of bronze and E.P.D.M.
rubber assures long-term maintenance-free operation.
- The drainage outlet enables removal of excess fluids (2" - 8").
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large sized air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 25 bar), achieved
by the A.R.I. patented rolling seal mechanism.

D-050 LP
Valve Selection

- Size range 2 12.


- These valves are manufactured with flanged ends to meet any
requested standard.
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The automatic air release component and the air & vacuum
component are available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-050 LP
DIMENSIONS AND WEIGHT
Nominal

Dimensions mm

Size

Connection

Weight

2 (50mm) Threaded

174

309

11

1 BSP Female

2 (50mm) Flanged

174

314

11

1 BSP Female

Nominal
Size

Dimensions mm

3 (80mm)

285

341

63.5

4 (100mm)

342

360

6 (150mm)

553

532

8 (200 mm)

553

532

Nominal

Dimensions mm

Size

Kg.

A/V

Auto.

8.9

794

5.6

11.9

794

Weight

external

74.6

11

17.9

80.0

96.0

11

124.0

140.0

11

124.0

140.0

11

internal

Orifice Area mm2

Weight
Kg.

Kg.

Orifice Area mm2


A/V

Auto.

1809

5.6

25.9

3317

5.6

76.1

17662

5.6

116.5

17662

5.6

Orifice Area mm2


A/V

Auto.

10 (250mm)

463

644

11

149.5

31400

5.6

12 (300mm)

586

788

11

161.5

49087

5.6

PARTS LIST AND SPECIFICATION


1

No. Part

Material

1.

Discharge Outlet

Polyethylene

2.

Cover & Shut Off Valve

Acetal

3.

Flat Plug

E.P.D.M

4.

Seat

Reinforced Polypropylene

5.

O-Ring

BUNA-N

6.

Seal

Silicone

7.

Float

Reinforced Polypropylene

11

8.

Body

Reinforced Nylon

12

9.

Cover

Ductile Iron ASTM A-536-60-40-18

10.

Orifice Seat

Bronze ASTM B-62 B271 C83600

11.

Orifice Seal

E.P.D.M

12.

O-Ring

BUNA-N

5
6
7
8

9
10

EnC-D050LPWTR-11 49

13.

Bolt, Nut & Washer

Steel Zinc Cobalt Plated

14.

Float

Polycarbonate / Stainless Steel

15.

Body

Ductile Iron ASTM A-536-60-40-18

Screen Cover 10-12

Polyethylene

14

/Cast Iron ASTM A-48 CL35B

15

/Ductile Iron ASTM A-536-60-40-18

13

D-060
D-060-C
D-062
D-065

PN 16
Water Supply

PN 16

PN 25
PN 40

Combination Air Valve for High Flow


Description

The D-060 series Combination Air Valve has the features of both an
air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.


D-060-C, D-062, D-065 - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.
- Water systems with pressure demands of 25 & 40 bar (D-062 &
D-065 respectively).

Operation

EnC-D060WTR-11 51

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a

partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valve's body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range:


D-060 0.2 - 16 bar
D-060-C 0.2 - 16 bar
D-062 0.2 - 25 bar
D-065 0.2 - 40 bar
- Testing pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.

D-060
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures
long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the standard
DIN 30677-2.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large size air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 40 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Valve Selection

Size Range: 1- 10
2" 8" (D-065 only)
D-060, made for 16 bar.
D-060-C, vandalism protected by a metal shell covering the air
release component, made for 16 bar.
D-062, vandalism protected by a metal shell covering the air release
component, made for 25 bar.
D-065, made for 40 bar.
- These valves are manufactured with flanged ends to meet any
requested standard.
- The 1", 2 valves are also available with a threaded BSP or NPT
connection.
- Valve coating: Fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The air release component and the air & vacuum component are
available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-060
D-060 1"

1
2

3
4
5
6
7

8
9
10

11
12
13
14
15
16

1" PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Body

Reinforced Nylon

2.

Discharge Outlet

Polypropylene

3.

Rolling Seal

4.

Clamping Stem

E.P.D.M.
Reinforced Nylon

EnC-D060WTR-11 53

5.

Float

Foamed Polypropylene

6.

O-Ring

BUNA-N

7.

Base

Reinforced Nylon

8.

Strainer

Nylon

9.

Cover

Ductile Iron ASTM A-536


60-40-18

10.

Orifice Seat

Bronze

11.

Orifice Seal

E.P.D.M.

12.

Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

13.

O-Ring

BUNA-N

14.

Body

Ductile Iron ASTM A-536


60-40-18

15.

Float

Polycarbonate / Stainless Steel

D-060
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connections

Weight

1 (25mm) Threaded

158

303

1 Female

1/8 Female

4.4

506.7

12

1 (25mm) Flanged

158

303

1 Female

1/8 Female

5.4

506.7

12

Nominal
Size

Dimensions mm

Kg.

Orifice Area mm2

Connection

Weight

Kg.

A/V

Auto.

Orifice Area mm2

2 (50mm) Threaded

215

347

1/8 Female

10

A/V
1960

Auto.
12

2 (50mm) Flanged

215

336

1/8 Female

11

1960

12

3 (80mm)

249

387

1/8 Female

18

5030

12

4 (100mm)

286

431

1/8 Female

25

7850

12

6 (150mm)

375

588

1/8 Female

78

17662

12

8 (200mm)

463

630

1/8 Female

117

31400

12

10 (250mm)

586

788

1/8 Female

150

49087

12

2"-10" PARTS LIST AND SPECIFICATION


1

No. Part Material

1. Body Reinforced Nylon


2. Discharge Outlet Polypropylene
3. Rolling Seal E.P.D.M.

4. Clamping Stem Reinforced Nylon

3
4

10

6. O-Ring BUNA-N

11

7. Base Brass ASTM B-124

12

8. Strainer Nylon

13

5. Float Foamed Polypropylene

9. Domed Nut & Washer Stainless Steel SAE 304


10. Screen Cover

2-4 Ductile Iron / Cast Iron


6-10 Polyethylene / Cast Iron / Ductile Iron

14
15

11. Threaded Rod Stainless Steel SAE 304

16

12. Screen Stainless Steel SAE 304

17

13. Cover Ductile Iron ASTM A-536 60-40-18


14. Bolt, Nut & Washer Steel, Zinc Cobalt Coated
15. Orifice Seat

Bronze

16. Orifice Seal

E.P.D.M.

17. O-Ring

BUNA-N

18
19

18. Float Polycarbonate / Stainless Steel


19. Body Ductile Iron ASTM A-536 60-40-18

D-060-C / D-062
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connections

1 (25mm) Threaded

152

291

1 Female

1 (25mm) Flanged

152

311

1 Female

Nominal
Size

Dimensions mm

Weight
Kg.

A/V

D-060-C

1/8 Female

5.3

506.7

12

1/8 Female

6.3

506.7

12

Connection

Weight

Orifice Area mm2


Auto.

D-062

Orifice Area mm2

Kg.

A/V

D-060-C

2 (50mm) Threaded

210

357

1/8 Female

10

1960

12

Auto.

2 (50mm) Flanged

210

325

1/8 Female

12

1960

12

3 (80mm)

243

393

1/8 Female

19

5030

12

4 (100mm)

280

438

1/8 Female

26

7850

12

6 (150mm)

375

596

1/8 Female

79

17662

12

8 (200mm)

463

638

1/8 Female

118

31400

12

10 (250mm)

586

788

1/8 Female

151

49087

12

D-062

PARTS LIST AND SPECIFICATION


1

No. Part Material


1.

Shell

D-060-C Cast Iron ASTM A-48 CL35B

D-060-C, D-062 Ductile Iron ASTM A-536-60-40-18

2
3

10

3. Discharge Outlet Brass ASTM B-124

11

4. Rolling Seal E.P.D.M.

12

5. Float Foamed Polypropylene

13

14

15

2. Body Reinforced Nylon

6. Clamping Stem Reinforced Nylon


7. O-Ring BUNA-N
8. Base Brass ASTM B124
9. Strainer Nylon
10. Domed Nut & Washer Stainless Steel SAE 304
11. Screen Cover

2-4 Ductile Iron / Cast Iron


6-10 Polyethylene / Cast Iron / Ductile Iron

12. Threaded Rod Stainless Steel SAE 304


13. Screen Stainless Steel SAE 304

16
17
18
19
20

14. Cover Ductile Iron ASTM A-536 60-40-18


15. Bolt, Nut & Washer Steel, Zinc Cobalt Coated
EnC-D060WTR-11 55

16.

Orifice Seat

Bronze

17.

Orifice Seal

E.P.D.M.

18.

O-Ring

BUNA-N

19. Float Polycarbonate / Stainless Steel


20. Body Ductile Iron ASTM A-536 60-40-18

D-065
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm Connection
A

2 (50mm) Threaded

246

500

2 (50mm) Flanged

246

3 (80mm)

280

4 (100mm)
6 (150mm)
8 (200mm)

Weight Orifice Area mm2


Kg.

A/V

Auto.

1/2 BSP Female

13.7

1960

15

487

1/2 BSP Female

15.7

1960

15

536

1/2 BSP Female

22.8

5030

15

317

580

1/2 BSP Female

29.6

7850

15

382

775

1/2 BSP Female

32.7

17662

15

472

813

1/2 BSP Female

121.7

31400

15

PARTS LIST AND SPECIFICATION


No. Part Material

1. Discharge Outlet PVC

2. Orifice Reinforced Nylon


3. Rollpin Stainless Steel SAE 304

4. O-Ring BUNA-N
5. Rolling Seal E.P.D.M.

3
4
5

6. Rollpin Stainless Steel SAE 304


7. Lever Reinforced Nylon

8. Rollpin Stainless Steel SAE 304

9. Cover Ductile Iron ASTM A536 60-40-18


10. O-Ring

BUNA-N

11. Bolt Nut & Washer Steel, Zinc Cobalt Coated

10

12. Float Polycarbonate / Stainless Steel


13. Body Ductile Iron ASTM A536 60-40-18
14. Adaptor

Brass

15. Domed Nut & Washer Stainless Steel SAE 304

2-4 Ductile Iron / Cast Iron

17

6-8 Polyethylene / Cast Iron / Ductile Iron

18

18. Screen Stainless Steel SAE 304

20

20. Bolt, Nut & Washer Steel, Zinc Cobalt Coated

21

21. Orifice Seat

Bronze

22. Orifice Seal

E.P.D.M.

22

23. O-Ring

BUNA-N

2"-4" Polycarbonate / Stainless Steel SAE 304

6"-8" Stainless Steel

13
14

19

19. Cover Ductile Iron ASTM A-536 60-40-18

24. Float

12

16

16. Screen Cover

17. Threaded Rod Stainless Steel SAE 304

11

15

23
24
25

25. Body Ductile Iron ASTM A-536 60-40-18

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-060 M1
D-060-C M1
D-062 M1
D-065 M1

PN 16
Water Supply

PN 16

PN 25
PN 40

Combination Air Valve for High Flow


Description

The D-060 M1 series Combination Air Valve has the features of


both an air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.


D-060-C M1 D-062 M1 D-065 M1 - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.
- Water systems with pressure demands of 25 & 40 bar (D-062 HF
M1 & D-065 HF M1 respectively).

Operation

EnC-D060M1WTR-11 57

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused by
water column separation. Air entery is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow

disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valve's body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

-Working pressure range:


D-060 M1 0.2 - 16 bar
D-060-C M1 0.2 - 16 bar
D-062 M1 0.2 - 25 bar
D-065 M1 0.2 - 40 bar
- Testing pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures

D-060 M1
long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large sized air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 40 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Valve Selection

- Sizes: 3, 4", 6, 8", 10", 12".


- D-060 M1, made for 16 bar.
- D-060-C M1 vandalism protected by a metal shell covering the air
release component, made for 16 bar.
- D-062 M1 vandalism protected by a metal shell covering the air
release component, made for 25 bar.
- D-065 M1 made for 40 bar. Sizes: 3-10".
- These valves are manufactured with flanged ends to meet any
requested standard.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The air release component and the air & vacuum component are
available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-060 M1

EnC-D060M1WTR-11 59

D-060 M1
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm Connection
A

3 (80mm)

225

334

1/8 BSP Female

4 (100mm)

257

385

6 (150mm)

307

428

8 (200mm)

375

10 (250mm)
12 (300mm)

Weight

A/V

Auto.

11

1960

12

1/8 BSP Female

18

5030

12

1/8 BSP Female

25

7850

12

588

1/8 BSP

78

17662

12

463

718

1/8 BSP Female

150

31400

12

586

846

1/8 BSP Female

162

49087

12

Female

Kg.

Orifice Area mm2

PARTS LIST AND SPECIFICATION


No. Part Material
1. Body Reinforced Nylon
2. Discharge Outlet Polypropylene
3. Rolling Seal E.P.D.M.
4. Clamping Stem Reinforced Nylon
5. Float Foamed Polypropylene
6. O-Ring BUNA-N
7. Base Brass ASTM B-124
1

8. Strainer Nylon
9. Domed Nut & Washer Stainless Steel SAE 304
10. Screen Cover

3"-6" Ductile Iron / Cast Iron


8"-12" Ductile Iron / Cast Iron / Polyethylene

11. Threaded Rod Stainless Steel SAE 304


12. Screen Stainless Steel SAE 304

15. Orifice Seat

Bronze

11

16. Orifice Seal

E.P.D.M.

12

17. O-Ring

BUNA-N

13

18. Float

3"-8", 12" Polycarbonate / Stainless Steel


10" Stainless Steel

19. Body Ductile Iron ASTM A-536 60-40-18

10

14. Bolt, Nut & Washer Steel, Zinc Cobalt Coated

4
5

13. Cover Ductile Iron ASTM A-536 60-40-18

7
8

14
15
16
17
18
19

D-060-C M1 / D-062 M1
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm Connection
A

3 (80mm)

219

344

4 (100mm)

251

394

Weight

Orifice Area mm2

Kg.

A/V

D-060-C

Auto.

1/8 BSP Female

13.6

1960

12

1/8 BSP Female

21.6

5330

12

D-062

6 (150mm)

302

436

1/8 BSP Female

37

7850

12

8 (200mm)

375

596

1/8 BSP

79

17662

12

10 (250mm)

463

724

1/8 BSP Female

151.0

31400

12

12 (300mm)

586

853

1/8 BSP Female

163.0

49087

12

Female

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Shell
D-060-C M1 Cast Iron ASTM A-48 CL35B
D-060-C M1, D-062 M1 Ductile Iron ASTM A-536-60-40-18
2. Body

Reinforced Nylon

3. Discharge Outlet

Brass ASTM B-124

4. Rolling Seal

Rubber E.P.D.M.

5. Float

Foamed Polypropylene

6. Clamping Stem

Reinforced Nylon

7. O-Ring BUNA-N
8. Base

Brass ASTM B124

9. Strainer Nylon
10. Domed Nut & Washer

Stainless Steel SAE 304

11. Screen Cover

Ductile Iron / Cast Iron

3"-6"
8"-12"

Ductile Iron / Cast Iron / Polyethylene

11

13. Screen

Stainless Steel SAE 304

14. Cover

Ductile Iron ASTM A-536 60-40-18

12

15. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

16. Orifice Seat

Bronze

17. Orifice Seal

E.P.D.M.

18. O-Ring

BUNA-N

19. Float

Polycarbonate / Stainless Steel

EnC-D060M1WTR-11 61

10" Stainless Steel

20. Body

Ductile Iron ASTM A-536 60-40-18

10

Stainless Steel SAE 304

3
4

12. Threaded Rod

3"-8", 12"

6
7
8

13

14
15

B
16
17
18
19
20

D-065 M1
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm Connection
A

3 (80mm)

256

487

1/2 BSP Female

4 (100mm)

288

535

6 (150mm)

339

579

8 (200mm)

382

10 (300mm)

463

Weight
Kg.

Orifice Area mm2


A/V

Auto.

12.6

1960

15

1/2 BSP Female

20.6

5030

15

1/2 BSP Female

36

7850

15

775

1/2 BSP Female

42.7

17662

15

724

1/2 BSP Female

151

31400

15

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Discharge Outlet

PVC

2. Orifice

Reinforced Nylon

3. Rollpin

Stainless Steel SAE 304

1
2

4. O-Ring BUNA-N

3
4
5

5. Rolling Seal

E.P.D.M.

6. Rollpin

Stainless Steel SAE 304

7. Lever

Reinforced Nylon

8. Rollpin

Stainless Steel SAE 304

9. Cover

Ductile Iron ASTM A536 60-40-18

10. O-Ring

BUNA-N

11. Bolt Nut & Washer

Steel, Zinc Cobalt Coated

12. Float

Polycarbonate / Stainless Steel

13. Body

Ductile Iron ASTM A536 60-40-18

14. Adaptor

Brass

15. Domed Nut & Washer

Stainless Steel SAE 304

16. Screen Cover

Ductile Iron / Cast Iron

18

Ductile Iron / Cast Iron / Polyethylene

19

17. Threaded Rod

Stainless Steel SAE 304

18. Screen

Stainless Steel SAE 304

20

19. Cover

Ductile Iron ASTM A-536 60-40-18

20. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

22

21. Orifice Seat

Bronze

23

22. Orifice Seal

E.P.D.M.

23. O-Ring

BUNA-N

24

24. Float

Polycarbonate / Stainless Steel

3"-6"
8", 10"

3"-6"
8", 10"

25. Body

9
10
11

15

12

16

13

17

14

21

25

Stainless Steel
Ductile Iron ASTM A-536 60-40-18

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-060 LP

Water Supply

PN 6

Combination Air Valve for High Flow, Low Pressure


Description

The D-060 LP series Combination Air Valve has the features of


both an air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.


- Low pressure systems.

Operation

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.

EnC-D060LPWTR-11 63

Without air valves, pockets of accumulated air may cause the


following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.

As the system starts to fill, the valve functions according to the


following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valve's body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.05 - 6 bar


- Testing pressure: 10 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures
long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the standard
DIN 30677-2.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large size air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 40 bar), achieved
by the A.R.I. patented rolling seal mechanism.

D-060 LP
Valve Selection

Size Range: 1- 10
- These valves are manufactured with flanged ends to meet any
requested standard.
- The 1", 2 valves are also available with a threaded BSP or NPT
connection.
- Valve coating: baked epoxy coating according to the standard DIN
30677-2.
- Other coatings are available upon request.
- The air release component and the air & vacuum component are
available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-060 LP
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm
B

Connection

Weight

Kg.

Orifice Area mm2


A/V

Auto.

1 (25mm) Threaded

152

280

11

1 Female

3.9

506.7

5.6

1 (25mm) Flanged

152

280

11

1 Female

4.9

506.7

5.6

Nominal
Size

Dimensions mm

Weight
Kg.

Orifice Area mm2

A/V

Auto.

2 (50mm) Threaded

210

325

11

9.5

1960

5.6

2 (50mm) Flanged

210

312

11

10.5

1960

5.6

3 (80mm)

244

360

11

17.5

5030

5.6

4 (100mm)

200

405

11

24.5

7850

5.6

6 (150mm)

375

600

11

77.5

17662

5.6

8 (200mm)

463

635

11

116.5

31400

5.6

10 (250mm)

586

818

11

149.5

49087

5.6

2"-10" PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Discharge Outlet

Polypropylene

2.

Cover & Shut Off Valve

Acetal

3.

Flat Plug

E.P.D.M

4.

Seat

Reinforced Polypropylene

5.

Seal

Silicone

6.

O-Ring

BUNA-N

7.

Float

Reinforced Polypropylene

10

8.

Body

Reinforced Nylon

11

9.

Domed Nut & Washer

Stainless Steel SAE 304

12

Screen Cover

Ductile Iron / Cast Iron

10.

2-4
6-10

C
9

Polyethylene / Cast Iron / Ductile Iron

13
14

EnC-D060LPWTR-11 65

11.

Threaded Rod

Stainless Steel SAE 304

12.

Screen

Stainless Steel SAE 304

13.

Cover

Ductile Iron ASTM A-536 60-40-18

16

14.

Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

17

15.

Orifice Seat

Bronze

16.

Orifice Seal

E.P.D.M.

18

17.

O-Ring

BUNA-N

18.

Float

Polycarbonate / Stainless Steel

19.

Body

Ductile Iron ASTM A-536 60-40-18

15

19

D-060 SB
D-060-C SB
D-062 SB

PN 16
Water Supply

PN 16

PN 25

Underground Air Valve System for Potable Water


Description

The D-060 SB is a complete product package that combines the


reliable and efficient properties of the A.R.I. D-060 Combination
Air Valve with the added feature of a sub-surface valve that can
be buried below ground. A specially designed gear box operated
horizontal sliding disc valve - situated at the base of the D-060 SB
assembly - allows for the air valve disconnection and maintenance
from ground level.
This gear box operated shut-off valve is equipped with a safety
mechanism enabling disconnection and removal of the D-060 air
valve from its subsurface housing, even when the system is under
pressure. Since service and maintenance operations of the unit are
performed entirely from the surface, there is no need for safety
considerations associated with confined space entry.
The D-060 Combination Air Valve has the features of both an air
release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Municipal and industrial water conveyance systems.

Operation

EnC-D060SBSWG-11 67

The air & vacuum component, with the large orifice, discharges
air at high flow rates during the filling of the system and admits air
into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float, which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air prevents pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from a destructive downsurge (vacuum conditions) and prevents
damage caused by water column separation. Air entry is essential to
efficiently drain the system.
The air release component releases entrapped air in pressurized
systems.

Without air valves, pockets of accumulated air may cause the


following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
The air valve functions according to the following stages:
1. As water fills the system, air in the pipeline is discharged by the
air valve.
2. Liquid enters the air valve, lifting the floats which push the
sealing mechanisms to their sealing position.
3. Entrapped air that accumulates along the system rises to the top
of the air release valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters the air release valve and the float rises, pushing the
rolling seal back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

D-060 SB Underground Air Valve System for Potable


Water:

- The D-060 SB incorporates an integral, flat, gear box operated


horizontal sliding disc valve with a 2, 3 full bore passage.
- The shut-off valve is operated from the surface.
- The quick connector between the adaptor and the shut-off valve
facilitates detachment during handling.
- The integrated assembly handle eases the process of lifting the air
valve assembly out from the valve box.
- Pipe connections: 3 threaded (BSP/NPT) or flanged, in
accordance with all standards.

D-060-SB
- Safety elements: Disengaging the air valve is safeguarded: unless
the shut-off valve is in the closed position and the internal
pressure is released, it is not possible to extract the air valve.
- All parts are corrosion resistant: Metal parts made of Stainless
Steel, Ductile Iron or steel, Composite material parts made of
Nylon.
- Drainage system: a special one-way valve that drains the water
from the valve box and does not admit water.

D-060 / D-060-C / D-062 Combination Air Valve:


- Working pressure range: D-060: 0.2 -16 bar

D-060-C: 0.2 - 16 bar

D-062: 0.2 - 25 bar

- Entirely operated and maintained from ground level.


- Reliable and efficient operation:
Dynamic design allows high velocity air discharge while
preventing premature closure.
A.R.I. patented Rolling Seal mechanism.
Since the valve is a sub-surface (underground), it is more resistant
to frost conditions.

Valve Selection
- Two different installation lengths:
1. 800mm tube; complete system length: 875 mm.
2. 1000mm tube; complete system length: 1075 mm.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

- Testing pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.

Sample Installation Scheme

- Dynamic design allows for high velocity air discharge while


preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures
long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the standard
DIN 30677-2.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large size air release orifice:
1. Dramatically reduces the possibility of obstruction by debris.
2. Discharges high air flow rates.
3. One size orifice for a wide pressure range (up to 25 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Advantages and Benefits

- Relatively lightweight and convenient to install.


- Sub-surface installation.
- Low installation costs:
- No need for expensive, large excavation.
- No need for expensive, human-accessible manholes.
- Low Maintenance costs:
- No need for specialized tools or safety equipment.
- One person for operation and maintenance.
- Clean and environmentally friendly.
- Safe in operation:
- Greatly reduces danger of contact with local fauna snakes and
scorpions, etc!

Important Information: Prior to site preparation and installation,


please refer to the D-060 SB Installation and Maintenance Manual
for all the relevant instructions and information. The manual can be
obtained by contacting the A.R.I marketing dept., from your local
A.R.I. distributor or downloading the file from our website.

D-060-SB
UNDERGROUND AIR VALVE SYSTEM
PARTS LIST AND SPECIFICATION

1
2

No. Part

Material

1.

Valve Box Cover

Polyethylene

2.

Pressure Relief Valve

Stainless Steel SAE 316

3.

Lifting Handle

Stainless Steel SAE 304

4.

Operating Rod

Stainless Steel SAE 304

5.

D-060 Air Valve

see below

6.

Sliding Disc Valve w/ Gear Box

DI+STST+E.P.D.M.

/STST+STST+E.P.D.M.

7.

Adaptor - Quick Connector

Stainless Steel SAE 316

8.

Safety Handle

Stainless Steel SAE 316

9.

Valve Box

3
4
5

Polyethylene

10. T Key

Stainless Steel SAE 304

11. Drainage One Way Valve Connection

Polypropylene + Acetal

12. Flange 3

Reinforced Nylon

/ Stainless Steel SAE 316

10
11
12

D-060 / D-060-C / D-062


PARTS LIST AND SPECIFICATION
1

No. Part

Material

1.

Cast Iron ASTM A-48 CL35B

Ductile Iron ASTM A-536-60-40-18

Shell

D-060-C
D-060-C / D-062

2. Body

Reinforced Nylon + Polypropylene

3. Discharge Outlet D-060

Reinforced Nylon

Brass ASTM B-124

D-060-C / D-062

10

11

EnC-D060SBSWG-11 69

4. Rolling Seal

E.P.D.M.

12

5. Float

Foamed Polypropylene

6. Clamping Stem

Reinforced Nylon

13

7. O-Ring

BUNA-N

14

8. Base

Brass ASTM B124

15

9. Strainer

Nylon

16

10. Domed Nut & Washer

Stainless Steel SAE 304

17

11. Screen Cover

Ductile Iron / Cast Iron

12. Threaded Rod

Stainless Steel SAE 304

18

13. Screen

Stainless Steel SAE 304

14. Cover

Ductile Iron ASTM A-536 60-40-18

15. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

16.

Orifice Seat

Bronze

17.

Orifice Seal

E.P.D.M.

18.

O-Ring

BUNA-N

19. Float

Polycarbonate / Stainless Steel

20. Body

Ductile Iron ASTM A-536 60-40-18

19
20

D-060-SB
DIMENSIONS AND WEIGHTS
Model

Dimensions mm

Weight Kg.

Orifice Area mm2

A/V

Auto.

L800 D-060

448

875

806

46.4

55.1

5030

12

L800 D-060-C / D-062

448

875

806

47.4

56.1

5030

12

L1000 D-060

448

1075

1006

49.4

58.1

5030

12

L1000 D-060-C / D-062

448

1075

1006

50.4

59.1

5030

12

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-060 NS
D-060-C NS
D-062 NS
D-065 NS

PN 16
Water Supply

PN 16

PN 25
PN 40

Combination Air Valve for High Flow - Non Slam


Description

The D-060 NS series Combination Air Valve has the features of both
an air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically discharge
or admit large volumes of air during the filling or draining of a
pipeline or piping system. This valve will open to relieve negative
pressures whenever water column separation occurs.

Applications

- Water pipelines with anticipated conditions of surge and water


hammer.
- On the peaks of water pipelines with steep slopes.
- Water pipelines where water column separation occurs.
D-060-C - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.
D-062 NS and D-065 NS - additional applications
- Water systems with pressure demands of 25 bar and 40 bar
(D-062 NS and D-065 NS respectively).

Operation

EnC-D060NSWTR-11 71

The D-060 HF NS series Combination Non Slam Air Valve is a


surge-dampening, slam-preventing, 3-stage combination air valve.
The air valve provides high capacity vacuum protection and, at the
same time, efficient surge suppression. At sudden drainage and/or
water column separation (sudden pump trips or valve closure, for
instance), the air & vacuum orifice admits air at high flow rates,
thus preventing vacuum. As the water column and/or pressure wave
returns, large volumes of air are discharged at high velocities, raising
the non-slam disc, partially closing the air & vacuum orifice and
allowing air to exhaust slowly through the smaller orifice of the nonslam disc. This slowly exhausting air pocket dampens the slam of the
returning water column, thus suppressing the pressure surge. As the
water flow arrives at a much slower rate, dampened by the slower
air discharge, it buoys up the main float, gently closing the air &
vacuum component of the air valve.
The S-050-C, S-052, S-015 air release component continues
releasing air while the pipeline and the air valve are pressurized.

Main Features

- Working pressure range:


D-060 NS: 0.2 -16 bar
D-060-C NS: 0.2 - 16 bar
D-062 NS: 0.2 - 25 bar
D-065 NS: 0.2 - 40 bar
- Testing pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures
long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the standard
DIN 30677-2.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large sized air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 40 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Valve Selection

- Size Range: 1- 10
2 8 (for model D-065 NS only)
- D-060 NS, for 16 bar
- D-060-C NS vandalism protected by a metal shell covering the air
release component, made for 16 bar.
- D-062 NS vandalism protected by a metal shell covering the air
release component, made for 25 bar.
- D-065 NS, made for 40 bar.
- These valves are manufactured with flanged ends to meet any
requested standard.

D-060 NS
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The automatic air release component and the air & vacuum
component are available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

Non-Slam Disc

The built- in throttling device on the Non-Slam disc of the D-060


HF NS Combination Air Valves will allow for the graduated opening
and closing of the disc orifice.
Advantages:
1. The orifice size of the disc can be adjusted to control and throttle
the discharge of air during pipeline filling and during the return of
the water column after separation.
2. The controlled discharge of air will reduce surge effects and
provide for a silent closure of the air valve.
3. The closure of the orifice can be determined by running a surge
analysis or by a decision taken in the field.
4. The orifice throttling device allows for a wide range of options
from 100% open, partially open, partially closed to 100% closed.

D-060 Non-Slam Orifice Data Table


Nominal
Size

Discharge
orifice mm

Total NS
area mm2

NS orifice
mm

Switching
point

Flow at
0.4 bar
m3/h

1 (25 mm)

37.5

12.6

Spring loaded
normally closed

17.5

2 (50mm)

50

63

10

90

3 (80mm)

75

175.4

15

23

240

4 (100mm)

100

476.4

24.5

23

350

6 (150mm)

150

900.6

34

23

600

8 (200mm)

200

1696.9

46.5

20

1850

10 (250mm)

250

1575.7

45

17

2800

D-060 NS

EnC-D060NSWTR-11 73

D-060 NS
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connections

1 (25mm) Threaded

250

303

1/8 BSP

Female

1 BSP

Female

4.4

506.7

12

1 (25mm) Flanged

250

303

1/8 BSP

Female

1 BSP

Female

5.4

506.7

12

Size

Dimensions mm

Orifice Area mm2

Nominal

Weight
Kg.

Connection

Weight

Kg.

A/V

Auto.

Orifice Area mm2

2 (50mm) Threaded

215

367

1/8 BSP Female

14

A/V
1960

Auto.
12

2 (50mm) Flanged

200

295

1/8 BSP Female

14

1960

12

3 (80mm)

215

367

1/8 BSP Female

21

5030

12

4 (100mm)

269

459

1/8 BSP Female

29

7850

12

6 (150mm)

375

707

1/8 BSP Female

78

17662

12

8 (200mm)

463

832

1/8 BSP Female

156

31400

12

10 (250mm)

586

993

1/8 BSP Female

291

49087

12

1" PARTS LIST AND SPECIFICATION


No. Part Material
1. Body Reinforced Nylon
2. Discharge Outlet Polypropylene
3. Rolling Seal E.P.D.M.
4. Clamping Stem Reinforced Nylon
5. Float Foamed Polypropylene
6. O-Ring BUNA-N
7. Base Reinforced Nylon

8. Strainer Nylon

9. Cover Ductile Iron ASTM A-536 60-40-18

10. One Way Check Valve Acetal

11. Orifice Seat

Bronze

12. Orifice Seal

E.P.D.M.

13. Bolt, Nut & Washer Steel, Zinc Cobalt Coated

14. O-Ring

BUNA-N

15. Body Ductile Iron ASTM A-536 60-40-18

16. Float Polycarbonate /Stainless Steel


17. Discharge Outlet Polypropylene

10
11
12
13
14
15
16

17

D-060 NS
2-10 PARTS LIST AND SPECIFICATION
No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M.

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Base

Brass ASTM B-124

8. Strainer

Nylon

9. Domed Nut & Washer

Stainless Steel SAE 304

10. Screen Cover

Ductile Iron / Cast Iron

2-4
6-10

11. Threaded Rod

Polyethylene / Cast Iron / Ductile Iron


Stainless Steel SAE 304

12. Screen

Stainless Steel SAE 304

1 3. Cover
14. Ring
2-4

6-10

Ductile Iron ASTM A-536 60-40-18


Stainless Steel SAE 316
Steel DIN ST.37

15. Non-Slam Disc 2-4



6-10

Stainless Steel SAE 316


Cast Iron ASTM A-48 CL.35B / Ductile Iron

16. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

17. Orifice Seat

Bronze

18. Orifice Seal

E.P.D.M.

19. O-Ring

BUNA-N

20. Float

Polycarbonate / Stainless Steel

21. Body

Ductile Iron ASTM A-536 60-40-18

1
2

10
11

4
5

12

13

14

15
16

17
18

EnC-D060NSWTR-11 75

19
20
21

D-060-C NS / D-062 NS
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connections

1 (25mm) Threaded

250

311

1/8 BSP Female

1 BSP

1 (25mm) Flanged

250

311

1/8 BSP Female

1 BSP

Nominal
Size

Dimensions mm

Weight

Kg.

A/V

D-060-C

Female

5.3

506.7

12

Female

6.3

506.7

12

Connection

Weight

Orifice Area mm2


Auto.

D-062

Orifice Area mm2

Kg.

A/V

D-060-C

2 (50mm) Threaded

209

375

1/8 BSP Female

15

1960

12

Auto.

2 (50mm) Flanged

209

362

1/8 BSP Female

15

1960

12

3 (80mm)

243

430

1/8 BSP Female

22

5030

12

4 (100mm)

280

473

1/8 BSP Female

30

7850

12

6 (150mm)

375

700

1/8 BSP Female

93

17662

12

8 (200mm)

463

800

1/8 BSP Female

157

31400

12

10 (250mm)

586

988

1/8 BSP Female

292

49087

12

D-062

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Shell
D-060-C HF

Cast Iron ASTM A-48 CL35B

D-060-C HF, D-062 HF

Ductile Iron ASTM A-536-60-40-18

2. Body

Reinforced Nylon

3. Discharge Outlet

10

2
3

Brass ASTM B-124

11

4. Rolling Seal

E.P.D.M.

12

5. Float

Foamed Polypropylene

6. Clamping Stem

Reinforced Nylon

13

7. O-Ring

BUNA-N

14

8. Base

Brass ASTM B124

15

9. Strainer

Nylon

16

10. Domed Nut & Washer

Stainless Steel SAE 304

11. Screen Cover

Ductile Iron / Cast Iron

2-4
6-10

Polyethylene / Cast Iron / Ductile Iron

17
18

12. Threaded Rod

Stainless Steel SAE 304

19

13. Screen

Stainless Steel SAE 304

14. Cover

Ductile Iron ASTM A-536 60-40-18

20

1 5. Ring

Stainless Steel SAE 316


Steel DIN ST.37

2-4
6-10

21
22

16. Non-Slam Disc 2-4



6-10

Stainless Steel SAE 316


Cast Iron ASTM A-48 CL.35B / Ductile Iron

17. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

18. Orifice Seat

Bronze

19. Orifice Seal

E.P.D.M.

20. O-Ring

BUNA-N

21. Float

Polycarbonate / Stainless Steel

D-062 NS 8 Stainless Steel only

22. Body

Ductile Iron ASTM A-536 60-40-18

D-065 NS
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm Connection
A

2 (50mm) Threaded

246

519

2 (50mm) Flanged

246

3 (80mm)

280

4 (100mm)

Weight Orifice Area mm2


Kg.

A/V

Auto.

1/2 BSP Female

15.3

1960

15

506

1/2 BSP Female

16.9

1960

15

572

1/2 BSP Female

25.5

5030

15

317

616

1/2 BSP Female

35

7850

15

6 (150mm)

389

854

1/2 BSP Female

94.9

17662

15

8 (200mm)

476

973

1/2 BSP Female

151.9

31400

15

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Discharge Outlet

PVC

2. Orifice

Reinforced Nylon

3. Rollpin

Stainless Steel SAE 304

1
2

4. O-Ring BUNA-N

C 3

5. Rolling Seal

E.P.D.M.

6. Rollpin

Stainless Steel SAE 304

7. Lever

Reinforced Nylon

8. Rollpin

Stainless Steel SAE 304

9. Cover

Ductile Iron ASTM A536 60-40-18

10. O-Ring

BUNA-N

11. Bolt Nut & Washer

Steel, Zinc Cobalt Coated

12. Float

Polycarbonate / Stainless Steel

13. Body

Ductile Iron ASTM A536 60-40-18

14. Adaptor

Brass

15

15. Domed Nut & Washer

Stainless Steel SAE 304

16

16. Screen Cover

2-4

Ductile Iron / Cast Iron

6-8 Polyethylene / Cast Iron / Ductile Iron

17

17. Threaded Rod

Stainless Steel SAE 304

18. Screen

Stainless Steel SAE 304

EnC-D060NSWTR-11 77

20. Ring

Stainless Steel SAE 316


Steel DIN ST.37

21

21. Non-Slam Disc 2-4



6-8

Stainless Steel SAE 316


Cast Iron ASTM A-48 CL.35B
/ Ductile Iron

23

22. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

23. Orifice Seat

Bronze

24. Orifice Seal

E.P.D.M.

26

25. O-Ring

BUNA-N

26. Float

2"-4"

Polycarbonate / Stainless Steel SAE 304

27

6"-8"

Stainless Steel
Ductile Iron ASTM A-536 60-40-18

12
13
14

19

Ductile Iron ASTM A-536 60-40-18 B

27. Body

11

18

19. Cover
2-4
6-8

10

20

22

24
25

D-060 NS
Operation in Rapid Filling of the Pipeline:

1. When water, rapidly filling the pipe line, pushes the air out
through the Air Valve, a differential air pressure is created across
the valve orifice.

2. When this differential pressure reaches a prefixed level (usually it


will be prefixed at 0.02 - 0.03 bar) the orifice disc will close.
3. Air will continue to come out through the small orifice disc - until
all the air will be exhausted and water will reach the kinetic float.
This double stage kinetic air discharge prevents the slam effect and
therefore suppresses water hammer.

4. When water reaches the kinetic float, it lifts it up, closing the
kinetic orifice and completing the kinetic cycle.
5. The vented Check Valve Orifice Disc will come back to its
normal open position.

6. When water is drained out of the pipe line, the resulting pressure
drop lets the kinetic float fall down, opening the orifice fully for
intake of high volume of air into the line.

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-060 NS M1
D-060-C NS M1
D-062 NS M1
D-065 NS M1

PN 16
Water Supply

PN 16

PN 25
PN 40

Combination Air Valve - Non Slam


Description

The D-060 NS M1 series Combination Air Valve has the features of


both an air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Water pipelines with anticipated conditions of surge and water


hammer.
- On the peaks of water pipelines with steep slopes.
- Water pipelines where water column separation occurs.
D-060-C NS M1 - additional applications
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.
D-062 NS M1 - additional applications
- Water systems with pressure demands of 25 bar (D-062 NS M1
respectively).
D-065 NS M1 - additional applications
- Water systems with pressure demands of 40 bar (D-065 NS M1
respectively).

Operation
EnC-D060NSM1WTR-11 79

The D-060 NS M1 series Combination Non Slam Air Valve is a


surge-dampening, slam-preventing, 3-stage combination air valve.
The air valve provides high capacity vacuum protection and, at the
same time, efficient surge suppression. At sudden drainage and/or
water column separation (sudden pump trips or valve closure, for
instance), the air & vacuum orifice admits air at high flow rates,
thus preventing vacuum. As the water column and/or pressure wave
returns, large volumes of air are discharged at high velocities, raising
the non-slam disc, partially closing the air & vacuum orifice and
allowing air to exhaust slowly through the smaller orifice of the nonslam disc. This slowly exhausting air pocket dampens the slam of the

returning water column, thus suppressing the pressure surge. As the


water flow arrives at a much slower rate, dampened by the slower
air discharge, it buoys up the main float, gently closing the air &
vacuum component of the air valve.
The S-050, S-050-C, S-052, S-015 air release component continues
releasing air while the pipeline and the air valve are pressurized.

Main Features

- Working pressure range:


D-060 NS M1: 0.2-16 bar
D-060-C NS M1: 0.2-16 bar
D-062 NS M1: 0.2-25 bar
D-065 NS M1: 0.2-40 bar
- Testing pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures
long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the standard
DIN 30677-2.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large sized air release orifice:
Dramatically reduces the possibility of obstruction by debris.
Discharges high air flow rates.
One size orifice for a wide pressure range (up to 25 bar), achieved
A.R.I patented rolling seal mechanism.

D-060 NS M1
Valve Selection

- Size Range: 3- 12
- D-060 NS M1 for 16 bar
- D-060-C NS M1 is vandalism protected by a cast metal air release
component shell, made for 16 bar
- D-062 NS M1 is vandalism protected by a cast metal air release
component shell, made for 25 bar
- D-065 NS M1 for 40 bar (3-10).
- These valves are manufactured with flanged ends to meet any
requested standard.

- Valve coating: baked epoxy coating according to the standard DIN


30677-2.
- Other coatings are available upon request.
- The automatic air release component and the air & vacuum
component are available as separate units.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-060 NS M1

EnC-D060NSM1WTR-11 81

D-060 NS M1
Nominal
Size

Dimensions mm
A

Connection

Weight

Orifice Area mm2

Kg.

A/V

Auto.

3 (80mm)

225

354

1/8 BSP Female

21

1960

12

4 (100mm)

257

422

1/8 BSP Female

29

5030

12

6 (150mm)

307

464

1/8 BSP Female

78

7850

12

8 (200mm)

375

689

1/8 BSP Female

156

17662

12

10 (250mm)

463

790

1/8 BSP Female

291

31400

12

12 (300mm)

586

987

1/8 BSP Female

300

49087

12

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M.

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Base

Brass ASTM B-124

8. Strainer

Nylon

9. Domed Nut & Washer

Stainless Steel SAE 304

10. Screen Cover

Ductile Iron/ Cast Iron

3-6
8-12

11. Threaded Rod

Polyethylene / Cast Iron / Ductile Iron


Stainless Steel SAE 304

12. Screen

Stainless Steel SAE 304

1 3. Cover
14. Ring
3-6

8-12
15. Flap
3-6

8-12

Ductile Iron ASTM A-536 60-40-18


Stainless Steel SAE 316
Steel DIN ST.37
Stainless Steel SAE 316
Cast Iron ASTM A-48 CL.35B
/ Ductile Iron

10
11

12

16. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

17. Orifice Seat

Bronze

18. Orifice Seal

E.P.D.M.

19. O-Ring

BUNA-N

1
2
9

13

20. Float

Polycarbonate / Stainless Steel

14

21. Body

Ductile Iron ASTM A-536 60-40-18

15

7
8

16

17
18
19
20
21

D-060-C NS M1/ D-062 NS M1


Nominal
Size

Dimensions mm
A

3 (80mm)

225

354

4 (100mm)

257

422

6 (150mm)

307

8 (200mm)
10 (250mm)
12 (300mm)

Connection
C

Weight

Orifice Area mm2

Kg.

A/V

D-060-C

Auto.

1/8 BSP Female

17

1960

12

1/8 BSP Female

26

5030

12

464

1/8 BSP Female

43.5

7850

12

375

689

1/8 BSP Female

91

17662

12

463

798

1/8 BSP Female

165

31400

12

586

989

1/8 BSP Female

301

49087

12

D-062

B
PARTS LIST AND SPECIFICATION
No. Part

Material

1. Shell
D-060-C HF

Cast Iron ASTM A-48 CL35B

D-060-C HF, D-062 HF

Ductile Iron ASTM A-536-60-40-18

2. Body

Reinforced Nylon

3. Discharge Outlet

Brass ASTM B-124

4. Rolling Seal

E.P.D.M.

5. Float

Foamed Polypropylene

6. Clamping Stem

Reinforced Nylon

7. O-Ring

BUNA-N

8. Base

Brass ASTM B124

9. Strainer

Nylon

10. Domed Nut & Washer

Stainless Steel SAE 304

11. Screen Cover

Ductile Iron / Cast Iron

3-6
8-12

Polyethylene / Cast Iron / Ductile Iron

EnC-D060NSM1WTR-11 83

12. Threaded Rod

Stainless Steel SAE 304

13. Screen

Stainless Steel SAE 304

14. Cover

Ductile Iron ASTM A-536 60-40-18

1 5. Ring

16. Flap

3-6
8-12
3-6

Stainless Steel SAE 316


Steel DIN ST.37
Stainless Steel SAE 316

8-12

Cast Iron ASTM A-48 CL.35B / Ductile iron

17. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

18. Orifice Seat

Bronze

19. Orifice Seal

E.P.D.M.

20. O-Ring

BUNA-N

21. Float

Polycarbonate / Stainless Steel

22. Body

Ductile Iron ASTM A-536 60-40-18

2
3

10

11

12

13

14

15

16
17
18
19
20
21
22

D-065 NS M1
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connection

Weight

3 (80mm)

256

506

1/2 BSP Female

4 (100mm)

290

572

6 (150mm)

340

616

8 (200mm)

389

854

10 (300)

476

973

Kg.

Orifice Area mm2


A/V

Auto.

12.6

1960

15

1/2 BSP Female

20.6

5030

15

1/2 BSP Female

36

7850

15

1/2 BSP Female

95

17662

15

1/2 BSP Female

152

31400

15

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Discharge Outlet

PVC

2. Orifice

Reinforced Nylon

3. Rollpin

Stainless Steel SAE 304

1
2

C 3

4. O-Ring BUNA-N
5. Rolling Seal

E.P.D.M.

6. Rollpin

Stainless Steel SAE 304

7. Lever

Reinforced Nylon

8. Rollpin

Stainless Steel SAE 304

9. Cover

Ductile Iron ASTM A536 60-40-18

10. O-Ring

BUNA-N

11. Bolt Nut & Washer

Steel, Zinc Cobalt Coated

12. Float

Polycarbonate / Stainless Steel

13. Body

Ductile Iron ASTM A536 60-40-18

14. Adaptor

Brass

15. Domed Nut & Washer

Stainless Steel SAE 304

16. Screen Cover

Ductile Iron / Cast Iron

3- 6
8, 10

Polyethylene / Cast Iron / Ductile Iron

17. Threaded Rod

Stainless Steel SAE 304

18. Screen

Stainless Steel SAE 304

19. Cover

Ductile Iron ASTM A-536 60-40-18

20. Ring

3- 6
8, 10

Stainless Steel SAE 316


Steel DIN ST.37

3- 6

Stainless Steel SAE 316

21. Flap

8, 10

Cast Iron ASTM A-48 CL.35B / Ductile Iron

4
5
6

14

19
20
21
22
23
24

Bronze

25

24. Orifice Seal

E.P.D.M.

26

25. O-Ring

BUNA-N

26. Float

Polycarbonate / Stainless Steel SAE 304

8-10

13

18

23. Orifice Seat

27. Body

12

17

Steel, Zinc Cobalt Coated

11

16

22. Bolt, Nut & Washer

3-6

10

15

27

Stainless Steel
Ductile Iron ASTM A-536 60-40-18

D-060 NS SB
D-060-C NS SB
D-062 NS SB

PN 16
Water Supply

PN 16

PN 25

Underground Air Valve System for Potable Water


Description

The D-060NS SB is a complete product package that combines


the reliable and efficient properties of the A.R.I. D-060 NS
Combination Air Valve with the added feature of a sub-surface valve
that can be buried below ground. A specially designed gear box
operated horizontal sliding disc valve - situated at the base of the
D-060 NS SB assembly - allows for the air valve disconnection and
maintenance from ground level.
This gear box operated shut-off valve is equipped with a safety
mechanism enabling disconnection and removal of the
D-060NS air valve from its subsurface housing, even when the
system is under pressure. Since service and maintenance operations
of the unit are performed entirely from the surface, there is no need
for safety considerations associated with confined space entry.
The D-060 NS series Combination Non Slam Air Valve is a surgedampening, slam-preventing, 3-stage combination air valve. The air
valve provides high capacity vacuum protection and, at the same
time, efficient surge suppression.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate along a pipeline
or piping system when it is full and operating under pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.
The non slam component is designed to throttle air discharge
through the smaller orifice of the non-slam disc to prevent surge.

Applications

3. This slowly exhausting air pocket dampens the slam of the


returning water column, thus suppressing the pressure surge.
4. As the water flow arrives at a much slower rate, dampened by the
slower air discharge, it buoys up the main float, gently closing the
air & vacuum component of the air valve.
5. The S-050 / S-050-C / S-052 air release component continues
releasing air while the pipeline and the air valve are pressurized.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.

Main Features

D-060 NS SB Underground Air Valve System for


Potable Water:

- The D-060 NS SB incorporates an integral, flat, gear box operated


horizontal sliding disc valve with a 2, 3 full bore passage.
- The shut-off valve is operated from the surface.

EnC-D060NSSBSWG-11 85

- Municipal and industrial water conveyance systems.

- The quick connector between the adaptor and the shut-off valve
facilitates detachment during handling.

Operation

- The integrated assembly handle eases the process of lifting the air
valve assembly out from the valve box.

The D-060 NS series Combination Non Slam Air Valve is a surgedampening, slam-preventing, 3-stage combination air valve. The air
valve provides high capacity vacuum protection and, at the same
time, efficient surge suppression.
1. At sudden drainage and/or water column separation (sudden
pump trips or valve closure, for instance), the air & vacuum orifice
admits air at high flow rates, thus preventing vacuum.
2. As the water column and/or pressure wave returns, large volumes
of air are discharged at high velocities, raising the non-slam disc,
partially closing the air & vacuum orifice and allowing air to exhaust
slowly through the smaller orifice of the non-slam disc.

- Pipe connections: 3 threaded (BSP/NPT) or flanged, in


accordance with all standards.
- Safety elements: Disengaging the air valve is safeguarded: unless
the shut-off valve is in the closed position and the internal
pressure is released, it is not possible to extract the air valve.
- All parts are corrosion resistant: Metal parts made of Stainless
Steel, Ductile Iron or steel, Composite material parts made of
Nylon.

D-060 NS-SB
D-060 NS / D-060-C NS / D-062 NS Combination Air

A.R.I. patented Rolling Seal mechanism.


Since the valve is a sub-surface (underground), it is more resistant
to frost conditions.

Valve:

Valve Selection

- Working pressure range: D-060 NS: 0.2 -16 bar



D-060-C NS: 0.2 - 16 bar

D-062 NS: 0.2 - 25 bar

- Two different installation lengths:


1. 800 mm tube; complete system length: 875 mm.
2. 1000 mm tube; complete system length: 1075 mm.

- Testing pressure for the air valve is 1.5 times its working pressure.

Upon ordering, please specify: model, size, working pressure,


threads standard and type of liquid.

- Drainage system: a special one-way valve that drains the water


from the valve box and does not admit water.

- Maximum working temperature: 60 C.


- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures
long-term maintenance-free operation.

Sample Installation Scheme

- Screen protected outlet.


- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the standard
DIN 30677-2.
Air Release Component
- Body made of high strength materials.
- All operating parts are made of specially selected corrosionresistant polymer materials.
- Large size air release orifice:
1. Dramatically reduces the possibility of obstruction by debris.
2. Discharges high air flow rates.
3. One size orifice for a wide pressure range (up to 25 bar), achieved
by the A.R.I. patented rolling seal mechanism.

Advantages and Benefits

- Relatively lightweight and convenient to install.


- Sub-surface installation.
- Low installation costs:
- No need for expensive, large excavation.
- No need for expensive, human-accessible manholes.
- Low Maintenance costs:
- No need for specialized tools or safety equipment.
- One person for operation and maintenance.
- Clean and environmentally friendly.
- Safe in operation:
- Greatly reduces danger of contact with local fauna snakes and
scorpions, etc!
- Entirely operated and maintained from ground level.
- Reliable and efficient operation:
Dynamic design allows high velocity air discharge while
preventing premature closure.

Important Information: Prior to site preparation and installation,


please refer to the D-060 NS SB Installation and Maintenance
Manual for all the relevant instructions and information. The manual
can be obtained by contacting the A.R.I marketing dept., from your
local A.R.I. distributor or downloading the file from our website.

D-060 NS-SB
UNDERGROUND AIR VALVE SYSTEM
PARTS LIST AND SPECIFICATION

1
2

No. Part

Material

1.

Valve Box Cover

Polyethylene

2.

Pressure Relief Valve

Stainless Steel SAE 316

3.

Lifting Handle

Stainless Steel SAE 304

4.

Operating Rod

Stainless Steel SAE 304

5.

Air Valve

see below

6.

Sliding Disc Valve w/ Gear Box

DI+STST+E.P.D.M.

/STST+STST+E.P.D.M.

7.

Adaptor - Quick Connector

Stainless Steel SAE 316

8.

Safety Handle

Stainless Steel SAE 316

9.

Valve Box

3
4
5

Polyethylene

10. T Key

Stainless Steel SAE 304

11. Drainage One Way Valve Connection

Polypropylene + Acetal

12. Flange 3

Reinforced Nylon

/ Stainless Steel SAE 316

10
11
12

D-060 NS / D-060-C NS / D-062 NS


PARTS LIST AND SPECIFICATION
No. Part

Material

1.

Cast Iron ASTM A-48 CL35B

Shell

D-060-C
D-060-C / D-062

Ductile Iron ASTM A-536-60-40-18

1
2

2.

Body

Reinforced Nylon

10

3.

Discharge Outlet D-060

Reinforced Nylon

11

Brass ASTM B-124

12

13

D-060-C / D-062

4.

Rolling Seal

E.P.D.M.

5.

Float

Foamed Polypropylene

6.

Clamping Stem

Reinforced Nylon

14

7.

O-Ring

BUNA-N

15

8.

Base

Brass ASTM B124

9.

Strainer

Nylon

16

10.

Domed Nut & Washer

Stainless Steel SAE 304

17

EnC-D060NSSBSWG-11 87

11.

Screen Cover

Ductile Iron / Cast Iron

18

12.

Threaded Rod

Stainless Steel SAE 304

13.

Screen

Stainless Steel SAE 304

19

14.

Cover

Ductile Iron ASTM A-536 60-40-18

1 5. Ring
16. Flap

Stainless Steel SAE 316


Stainless Steel SAE 316

17.

Steel, Zinc Cobalt Coated

Bolt, Nut & Washer

18.

Orifice Seat

Bronze

19.

Orifice Seal

E.P.D.M.

20.

O-Ring

BUNA-N

21.

Float

Polycarbonate / Stainless Steel

22.

Body

Ductile Iron ASTM A-536 60-40-18

20
21
22

D-060 NS-SB
DIMENSIONS AND WEIGHTS
Model

Dimensions mm

Weight Kg.

Orifice Area mm2

A/V

Auto.

L800 D-060 NS

448

875

806

49.5

59.5

5030

12

L800 D-060-C NS / D-062 NS

448

875

806

50.5

60.5

5030

12

L1000 D-060 NS

448

1075

1006

52.5

62.5

5030

12

L1000 D-060-C NS / D-062 NS

448

1075

1006

53.5

63.5

5030

12

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-070

Water Supply

PN 16

Dynamic Combination Air Valve PATENTED


Description

The D-070 Dynamic Combination Air Valve is a unique valve,


operating without a float and utilizing the rolling diaphragm
principle. This unique structure allows the dynamic air valve to
discharge air from the water system in a controlled and gradual
manner, thus preventing slam and local up-surges. When vacuum
(down-surge) occurs, the valve reacts quickly to admit large volumes
of air into the water system, thus impeding down-surges and,
consequently, all pressure surges in the line. The air & vacuum
component of the dynamic air valve is normally closed when the
line is not operating, thus preventing the infiltration of debris and
insects into the water system.

sealing assembly to rise up into its open position, opening the


lower chamber large orifice and allowing the intake of air from the
atmosphere into the system.

Main Features

- Pumping stations, deep wells and distribution lines.


- Systems that are prone to slam and local and system surges.
- Sites that require a combination of means to reduce water hammer
or surges.
- Sites that require an air valve with a low profile due to lack of
space.

- Working pressure range: 0.2 - 16 bar.


- Testing pressure: 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Internal components are corrosion-resistant.
- Prevents slam and reduces water surges in the air valve and the
pipeline.
- Prevents the intrusion of debris and contaminants into the system.
- Valve is lightweight and small for easy installation; its operation
simple and reliable.
- Built-in connection at the outlet for surplus water drainage.
- Smooth and gradual closing unaffected by water flow.
- Extremely quiet closing.
- Automatic air release component releases large quantities of air
without becoming obstructed.

Operation

Valve Selection

Applications

EnC-D070WTR-11 89

When the system is charged and the pipeline begins to fill with
water, air flows in the pipeline and enters into the dynamic air valve,
raising the rolling diaphragm sealing assembly to the open position.
Air is then discharged, mainly out through the lower chamber large
orifice as well as small amounts of air released out through upper
chamber operating valve orifice. When the ensuing water enters the
dynamic air valve, it fills the lower chamber and some of it flows
up through the orifice chamber and enters into the upper operating
chamber, raising the float of the operating valve which rolls the
sealing mechanism to its sealed position. Pressure develops inside
the upper operating chamber, bringing about a controlled lowering
and sealing of the rolling diaphragm sealing assembly, which, in
turn, closes the lower chamber large orifice.
NOTE: It is recommended to attach a drainage pipe to the
connection on the large orifice outlet as some water will be expelled
from the orifice during this closure stage. The size of the drainage
pipe should be, at a minimum, the diameter of the outlet and the
unattached end should remain open to the atmosphere.
At this stage, only the automatic air release component continues
to function and releases air through its small orifice. With a
reduction in line pressure, during drainage or shut-off, the pressure
in the valve is reduced and is lower then the outside atmospheric
pressure. The vacuum created will cause the rolling diaphragm

- Sizes: 3, 4, 6, 8 and 12.


- Valves are manufactured with flanged ends to meet any requested
standard.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- Optional D-070 P Sizes: 2, 3 (threaded or flanged) & 4
(flanged only); made of composite materials (suitable for agricultural
installations) with a working pressure: 0.2 - 10 bar.
- Optional one-way D-070-I valve - intakes air only, without
allowing air discharge.
- For best fit, it is recommended that the composition of liquids and
system requirements be defined in advance.
When ordering, please indicate the model, dimensions, working
pressure, threading/flange standard and special coatings.

D-070

D-070
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connections

3 (80 mm)

233

290

3 Vic / BSP / NPSM

3/8 BSP Female

4 (100 mm)

250

311

4 Vic.

6 (150 mm)

378

392

6 Vic.

8 (200 mm)

410

454

12 (300mm)

565.9

724.5

Weight
Kg.

Orifice Area mm2


Auto.

A &V

14

7.8

5153

3/8 BSP Female

21

7.8

7850

1 BSP Female

39

12

17553

8 Vic.

1 BSP Female

69.5

12

31400

12 Vic.

2 BSP Female

155.5

12x3

70650

3 - 8 PARTS LIST AND SPECIFICATION


No. Part Material
1. Operating Valve Body Reinforced Nylon
2. Discharge Outlet Polypropylene
3. Rolling Seal

3 4 E.P.D.M. Rubber

Sealing Assembly 6 8 E.P.D.M. Rubber + Reinforced Nylon


+ St.St. SAE 316
4. Operating Assembly Foamed Polypropylene + St.St. SAE 304 + Acetal
5. Clamping Stem Reinforced Nylon
6. O-ring BUNA-N
7. Bolt, Nut & Washer Steel Zinc Cobalt Coated
8. Cover Ductile Iron ASTM A-536-60-40-18
9. Rolling Diaphragm
Sealing Assy. Reinforced Nylon + E.D.P.M. Rubber
+ SAE 304 St.St. + Natural Rubber
+ Fabric
10. Orifice Seat Bronze ASTM B-62 B271 WCB
11. Body Ductile Iron ASTM A-536-60-40-18

D-070 3, 4

D-070 6, 8
1

5
EnC-D070WTR-11 91

7
8

7
8

10

10

11

11

D-070
12 PARTS LIST AND SPECIFICATION
No.

Part

Material

1.

O-Ring

BUNA-N

2.

Operating Valve Body

Ductile Iron ASTM A-536-60-40-18

3.

Internal Check Valve

Acetal

4.

Operating Valve Cover

Ductile Iron ASTM A-536-60-40-18

5.

Operating Valve Orifice Seat

Bronze ASTM B-62 B271 WCB

6.

Operating Valve Orifice Seal

E.P.D.M.

7.

Operating Valve Float

Polycarbonate

8.

Operating Valve Plug

Brass

9.

Body

Reinforced Nylon

10.

Discharge Outlet

Polypropylene

11.

Rolling Seal

E.P.D.M.

12.

Clamping Stem

Reinforced Nylon

13.

Float

Foamed Polypropylene

14.

O-Ring

BUNA-N

15.

Tube

Polyethylene

16.

Base

Brass ASTM B-124

17.

Strainer

Nylon

18.

Bolt, Nut & Washer

Steel Zinc Cobalt Coated

19.

Cover

Ductile Iron ASTM A-536-60-40-18

20.

Body

Ductile Iron ASTM A-536-60-40-18

21.

Rolling Diaphragm Sealing Assy.

Reinforced Nylon + E.D.P.M. Rubber


+ St.St. SAE 304 + Natural Rubber + Fabric

22.

Orifice Seat

Stainless Steel SAE 316

23.

Ball Valve 1/2

Brass, Nickel Plated

D-070 12

8
9
10

11
12
13
14

18

15

19

16

20

17

21
22
23

A
A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988
A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-070 M1

Water Supply

PN 16

Dynamic Combination Air Valve PATENTED


Description

The D-070 M1 Dynamic Combination Air Valve is a unique


valve, operating without a float and utilizing the rolling diaphragm
principle. This unique structure allows the dynamic air valve to
discharge air from the water system in a controlled and gradual
manner, thus preventing slam and local up-surges. When vacuum
(down-surge) occurs, the valve reacts quickly to admit large volumes
of air into the water system, thus impeding down-surges and,
consequently, all pressure surges in the line. The air & vacuum
component of the dynamic air valve is normally closed when the
line is not operating, thus preventing the infiltration of debris and
insects into the water system.

sealing assembly to rise up into its open position, opening the


lower chamber large orifice and allowing the intake of air from the
atmosphere into the system.

Main Features

- Pumping stations, deep wells and distribution lines.


- Systems that are prone to slam and local and system surges.
- Sites that require a combination of means to reduce water hammer
or surges.
- Sites that require an air valve with a low profile due to lack of
space.

- Working pressure range: 0.2 - 16 bar.


- Testing pressure: 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Internal components are corrosion-resistant.
- Prevents slam and reduces water surges in the air valve and the
pipeline.
- Prevents the intrusion of debris and contaminants into the system.
- Valve is lightweight and small for easy installation; its operation
simple and reliable.
- Built-in connection at the outlet for surplus water drainage.
- Smooth and gradual closing unaffected by water flow.
- Extremely quiet closing.
- Automatic air release component releases large quantities of air
without becoming obstructed.

Operation

Valve Selection

Applications

EnC-D070M1WTR-11 93

When the system is charged and the pipeline begins to fill with
water, air flows in the pipeline and enters into the dynamic air valve,
raising the rolling diaphragm sealing assembly to the open position.
Air is then discharged, mainly out through the lower chamber large
orifice as well as small amounts of air released out through upper
chamber operating valve orifice. When the ensuing water enters the
dynamic air valve, it fills the lower chamber and some of it flows
up through the orifice chamber and enters into the upper operating
chamber, raising the float of the operating valve which pushes the
sealing mechanism to its sealed position. Pressure develops inside
the upper operating chamber, bringing about a controlled lowering
and sealing of the rolling diaphragm sealing assembly, which, in
turn, closes the lower chamber large orifice.
NOTE: It is recommended to attach a drainage pipe to the
connection on the large orifice outlet as some water will be expelled
from the orifice during this closure stage. The size of the drainage
pipe should be, at a minimum, the diameter of the outlet and the
unattached end should remain open to the atmosphere.
At this stage, only the automatic air release component continues
to function and releases air through its small orifice. With a
reduction in line pressure, during drainage or shut-off, the pressure
in the valve is reduced and is lower then the outside atmospheric
pressure. The vacuum created will cause the rolling diaphragm

- Sizes: 4", 6", 8" and 10".


- Valves are manufactured with flanged ends to meet any requested
standard.
- Optional :
D-070 sizes : 3 8 , 12"
D-070 P Sizes: 2, 3 (threaded or flanged) & 4 (flanged only);
made of composite materials with a working pressure: 0.2 - 10 bar.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- Additional one-way D-070 M1-I valve - intakes air only, without
allowing air discharge.
- For best fit, it is recommended that the composition of liquids and
system requirements be defined in advance.
When ordering, please indicate the model, dimensions, working
pressure, threading/flange standard and special coatings.

D-070 M1

D-070 M1
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connections

4 (100 mm)

247

291

3 Vic / BSP / NPSM

6 (150 mm)

285

311.5

8 (200 mm)

403

393

10 (250 mm)

437

455

Orifice Area mm2


Auto.

A &V

3/8 BSP Female

7.8

5153

4 Vic.

3/8 BSP Female

7.8

7850

6 Vic.

1 BSP Female

12

17553

8 Vic.

1 BSP Female

12

31400

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Operating Valve Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M. Rubber

4 6

Sealing Assembly 8 10

E.P.D.M. Rubber + Reinforced Nylon


+ St.St. SAE 316

4. Operating Assembly

Polypropylene + St.St. SAE 304

5. Clamping Stem

Reinforced Nylon

6. O-ring

BUNA-N

7. Bolt, Nut & Washer

Steel Zinc Cobalt Coated

8. Cover

Ductile Iron ASTM A-536-60-40-18

9. Rolling Diaphragm
Sealing Assy.

Reinforced Nylon + E.D.P.M. Rubber


+ SAE 304 St.St. + Natural Rubber + Fabric

10. Orifice Seat

Bronze ASTM B-62 B271 WCB

11. Body

Ductile Iron ASTM A-536-60-40-18

D-070 M1 4, 6

D-070 M1 8, 10
1

6
EnC-D070M1WTR-11 95

6
7

B C

10

10

11

11

D-070-P

Water Supply

PN 10

Dynamic Combination Air Valve


Description

The D-070-P Dynamic Combination Air is a unique valve,


operating without a float and utilizing the rolling diaphragm
principle. This unique structure allows the dynamic air valve to
discharge air from the water system in a controlled and gradual
manner, thus preventing slam and local up-surges. When vacuum
(down-surge) occurs, the valve reacts quickly to admit large volumes
of air into the water system, thus impeding down-surges and,
consequently, all pressure surges in the line. The air & vacuum
component of the dynamic air valve is normally closed when the
line is not operating, thus preventing the infiltration of debris and
insects into the water system.

Applications

Recommended installations:
-Standard installation on water systems when the pipeline diameter
is 8 or greater.
-Installation on water systems for all pipeline diameters when the
slope of the pipeline is greater than 2%-3%.

Operation

PATENTED
atmospheric pressure. The vacuum created will cause the rolling
diaphragm sealing assembly to rise up into its open position,
opening the lower chamber large orifice and allowing the intake of
air from the atmosphere into the system.

Main Features

- Working pressure: 0.2 - 10 bar.


- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Valve body and interior components are made from composite
materials and are corrosion-resistant.
- Prevents slam and reduces water surges in the air valve and the
pipeline.
- Prevents the intrusion of debris and contaminants into the system.
- Valve is lightweight and small for easy installation; its operation
simple and reliable.
- Built-in connection at the outlet for surplus water drainage.
- Smooth and gradual closing unaffected by water flow.
- Extremely quiet closing.
- Automatic air release component releases large quantities of air
without becoming obstructed.

EnC-D070PWTR-11 97

When the system is charged and the pipeline begins to fill with
water, air flows in the pipeline and enters into the dynamic air valve,
raising the rolling diaphragm sealing assembly to the open position.
Air is then discharged, mainly out through the lower chamber large
orifice as well as small amounts of air released out through upper
chamber operating valve orifice. When the ensuing water enters the
dynamic air valve, it fills the lower chamber and some of it flows
up through the orifice chamber and enters into the upper operating
chamber, raising the float of the operating valve which rolls the
sealing mechanism to its sealed position. Pressure develops inside
the upper operating chamber, bringing about a controlled lowering
and sealing of the rolling diaphragm sealing assembly, which, in
turn, closes the lower chamber large orifice.
NOTE: It is recommended to attach a drainage pipe to the external
threads on the large orifice outlet as some water will be expelled
from the orifice during this closure stage. The size of the drainage
pipe should be, at a minimum, the diameter of the outlet and the
unattached end should remain open to the atmosphere.

Valve Selection

At this stage, only the automatic air release component continues to


work and releases air through its small orifice.
With a reduction in line pressure, during drainage or shut-off,
the pressure in the valve is reduced and is less then the outside

When ordering, we recommend that the composition of liquids and


system requirements be defined in advance.

Sizes: D-070-P 2 threaded or flanged


D-070-P M1 3 threaded or flanged


D-070-P M2 4 flanged only.
The valve body is also available in Ductile Iron ASTM A-536-604018, in sizes 3, 4, 6, 8, 12 in a wide range of flange standards.
Options:
- D-070-P I
One-way valve intakes air only,
without allowing air discharge.
- D-070-P T
Valve with flushing tap for the purpose of both
flushing the valve and the pipeline.
- Bug Screen
Attached to the valve outlet, prevents the
penetration of debris or insects into the air valve.

When ordering, please indicate the required model, dimensions,


working pressure and thread/flange standard.

D-070-P

DIMENSIONS AND WEIGHTS


Nominal

Dimensions mm

Size

Connections

Weight

Kg.

D-070-P 2 (50 mm) Threaded

144

216

2 BSP Male

3/8 BSP Female

D-070-P 2 (50 mm) Flanged

165

224

2 BSP Male

D-070-P M1 3 (80 mm) Threaded

144

217

2 BSP Male

D-070-P M1 3 (80 mm) Flanged

200

228

D-070-P M2 4 (100 mm)

228

217

Orifice Area mm2


Auto.

A &V

1.040

7.8

1963

3/8 BSP Female

1.440

7.8

1963

3/8 BSP Female

1.075

7.8

1963

2 BSP Male

3/8 BSP Female

1.665

7.8

1963

2 BSP Male

3/8 BSP Female

1.860

7.8

1963

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Discharge Outlet

Polypropylene

2.

Operating Valve Body

Reinforced Nylon

3.

Rolling Seal

4.

Operating Assembly

3
4

E.P.D.M.
Foamed Polypropylene
+ St.St. SAE 304

5.

Clamping Stem

Reinforced Nylon

6.

O-Ring

BUNA-N

7.

Locking Ring

Reinforced Nylon

8.

Base Adaptor

Reinforced Nylon

9.

Supporting Ring

Reinforced Nylon

Rolling Diaphragm

Reinforced Nylon +

10

Sealing Assy.

E.D.P.M. + St.St. SAE 304

11

10.

8
9

+ Fabric
11.

Body

Reinforced Nylon

A
A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988
A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-070-VB

Water Supply

PN 16

Vacuum Breaker Valve


Description

The D-070 VB Dynamic Vacuum Breaker is a unique air valve,


operating without a float and utilizing the rolling diaphragm
principle. When vacuum (down-surge) occurs, the dynamic vacuum
breaker reacts quickly to admit large volumes of air into the water
system, thus impeding down-surges and, consequently, all pressure
surges in the line.
The D-070 VB valve allows for air intake only, without discharging
air into the atmosphere.
The valve is normally closed when the line is not operating, thus
preventing the infiltration of debris and insects into the water
system.

Applications

- Pumping stations, deep wells, and distribution lines.


- Systems prone to slam and local and system surges.
- Sites that require a combination of means to reduce water hammer
or surges.
- Sites that require an vacuum breaker with a low profile due to lack
of space.

Operation

With a reduction in line pressure, during drainage, shut-off or water


column separation, the pressure in the valve is reduced and is lower
then the outside atmospheric pressure. The vacuum created will
cause the rolling diaphragm sealing assembly to rise up into its open
position, opening the lower chamber large orifice and allowing the
intake of air from the atmosphere into the system.

Main Features

EnC-D070VBWTR-11 99

- Working pressure range: 0.2 - 16 bar.


- Testing pressure: 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Internal components are corrosion-resistant.
- Prevents slam and reduces water surges in the air valve and the
pipeline.
- Prevents the intrusion of debris and contaminants into the system.
- Valve is lightweight and small for easy installation; its operation
simple and reliable.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.

D-070 VB
Valve Selection

DIMENSIONS AND WEIGHTS


Nominal

Dimensions mm

Connection

Weight

Orifice Area

230

3 Vic / BSP / NPSM

14

5153

250

245

4 Vic.

21

7850

350

318

6 Vic.

39

17553

8 (200 mm)

410

379

8 Vic.

69.5

31400

12 (300mm)

568.5

491

12 Vic.

142.5

70650

Size

3 (80 mm)

233

4 (100 mm)
6 (150 mm)

Kg.

- The valve is manufactured in dimensions of


3"- 8", 12" flanged.
- Can be provided with flanged BS, ANSI,
DIN, GIS standards.
- Other coatings are available upon request.
- For best fit, it is recommended that the
composition of liquids and system requirements
be defined in advance.

mm2

- For selecting the correct valve and its location,


use the recommendations sheet and check with
the Marketing Department.

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Bolt, Nut & Washer

Steel Zinc Cobalt Coated

2.

Orifice Seat

Bronze ASTM B-62 B271 WCB

3.

O-Ring

BUNA-N

4.

Plug

Acetal

5.

Cover

Ductile Iron ASTM A-536-60-40-18

6.

Rolling Diaphragm Sealing Assy.

Reinforced Nylon + E.D.P.M. + St.St. SAE


304 + Natural Rubber + Fabric

7.

Body

Ductile Iron ASTM A-536-60-40-18

8.

Ball Valve 1/2

Brass, Nickel Plated

D-070 VB 12"

D-070 VB 3" - 8"


1

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

K-010
K-014
K-100

PN 16
PN 40

K-012
K-016

PN 25
Water Supply

PN 64

PN 100

Air & Vacuum Valve


Description

The K-010 series Air & Vacuum Valve discharges air during the
filling or charging of the system and admits air into the system
during system drainage, valve or pump shut-off or at water column
separation.

Applications

- Municipal and industrial water conveyance systems.


K-012 - K-100
- Water conveyance systems requiring high pressure valves.

Operation

The air & vacuum valve discharges air at high flow rates during the
filling of the system and admits air at high flow rates during the
drainage , pump shut-off or at water column separation.
High velocity air will not blow the float shut. Water entry will cause
the sealing of the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air prevents pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.

- Reliable operation reduces water hammer incidents.


- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- Special orifice seat design: combination of bronze and E.P.D.M.
rubber assures long-term maintenance-free operation.
- The discharge outlet enables removal of excess fluids (2 - 8).

Valve Selection

- K-010 (16 bar) / K-012 (25 bar) - available in sizes 2 - 12.


- K-014 (40 bar) available in sizes 2 - 10.
- K-016 (64 bar) / K-100 (100 bar) - available in sizes 2 - 8.
- These valves are manufactured with flanged ends to meet any
requested standard.
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The K- 010 series air & vacuum (except for the K-100) valve
is also available as a combination air valve which includes an
automatic air release valve.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

As the system starts to fill, the valve functions according to the


following stages:
1. Entrapped air is discharged by the valve.
2. The liquid enters the valve, lifting the float and sealing the valve.

Main Features

- Working pressure range: 0.2 - 100 bar.


- Testing Pressure: 1.5 times the working pressure of the air valve.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.

6 - 8

EnC-K010WTR-11 101

K-010 / K-012 / K-014

When internal pressure falls below atmospheric pressure


(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
the orifice.
2. Air will enter the system.
10

6 - 8

3 - 4

6 - 8

2 - 4

K-100 / K-016

K-010 / K-012 / K-014 / K-016 / K-100


DIMENSIONS AND WEIGHT
Nominal

Dimensions mm

Size

Connection

Weight

Orifice Area

238

1 BSP Female

8.4

794

238

1 BSP Female

11.4

794

2 (50mm) Threaded

160

2 (50mm) Flanged

166

Nominal
Size

Kg.

Dimensions mm
B

internal

mm2

Weight
external

Kg.

Orifice Area
mm2

3 (80mm)

285

255

63.5

74.6

17.5

1809

4 (100mm)

342

285

80.0

96.0

27

3317

6 (150mm)

553

530

124.0

140.0

77

17671

8 (200 mm)

553

530

124.0

140.0

116

17671

10 (250mm)

463

642

NA

NA

149

31415

12 (300mm)

586

789

NA

NA

163

49087

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Bolt, Nut & Washer

Steel Zinc Cobalt Plated

2. Plug

Brass ASTM B124

3. Orifice Seal

E.P.D.M

4. Orifice Seat

Bronze ASTM B-62 B271 C83600

5. Float

Polycarbonate / Stainless Steel

6. O-Ring

BUNA-N

7. Body 16,25,40 bar

Ductile Iron ASTM A-536-60-40-18

40,64,100 bar

8. Cover 16,25,40 bar


C
B

Cast Steel ASTM A-216 WCB


Ductile Iron ASTM A-536-60-40-18

40,64,100 bar

2,3,4 Cast Steel Din St.37

68 Cast Steel A148-115-95

* Screen Cover 10-12

Polyethylene

/Cast Iron ASTM A-48 CL35B

/Ductile Iron ASTM A-536-60-40-18

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

K-010 M1
K-012 M1

PN 16

Water Supply

PN 25

Air & Vacuum Valve


Description

The K-010 M1 series Air & Vacuum Valve discharges air during
the filling or charging of the system and admits air into the system
during system drainage, valve or pump shut-off or at water column
separation.

Applications

- Municipal and industrial water conveyance systems.


K-012 M1
- Water conveyance systems requiring high pressure valves.

Operation

The air & vacuum valve discharges air at high flow rates during the
filling of the system and admits air at high flow rates during the
drainage , pump shut-off or at water column separation.
High velocity air will not blow the float shut. Water entry will cause
the sealing of the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air prevents pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air is discharged by the valve.
2. The liquid enters the valve, lifting the float and sealing the valve.

EnC-K010M1WTR-11 103

When internal pressure falls below atmospheric pressure


(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
orifice.
2. Air will enter the system.

Main Features

- Working pressure range:


K-010 M1 0.2 - 16 bar, K-012 M1 0.2 - 25 bar
- Testing Pressure: 1.5 times the working pressure of the air valve.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- Special orifice seat design: combination of bronze and E.P.D.M.
rubber assures long-term maintenance-free operation.
- The discharge outlet enables removal of excess fluids.

Valve Selection

- K-010 M1 (16 bar) / K-012 M1 (25 bar)


- Available in sizes 2, 3, 6.
- These valves are manufactured with flanged ends to meet any
requested standard.
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Valve coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- The K-010 series air & vacuum (except for the K-100) valve is also
available as a combination air valve which includes an automatic air
release valve.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

K-010 M1
DIMENSIONS AND WEIGHTS
Nominal

Size

Dimensions mm

Connection

Weight

Orifice Area

217

1/2 BSP Female

4.0

794

149

229

1/2 BSP Female

6.1

794

160

266

2 BSP Female

9.6

1809

160

264

2 BSP Female

12.6

1809

2 (50mm) Threaded

149

2 (50mm) Flanged
3 (80mm) Threaded
3 (80mm) Flanged
Nominal

Size

6 (150mm)

A
400

Kg.

Dimensions mm
B

internal

334

90

mm2

Weight
external

Kg.

Orifice Area

124

43.0

7850

mm2

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Cover

Ductile Iron STM A-536 60-40-18

2. Plug

Brass ASTM B124

3. Orifice Seat

Bronze ASTM B-62 B271 C83600

4. Orifice Seal

Natural and Synthetic Rubber

5. O-Ring

BUNA-N

6. Bolt and Nut

Steel Zinc Cobalt Plated

7. Float

Polycarbonate / Stainless Steel SAE 304L

8. Body

Ductile Iron STM A-536 60-40-18

2
3
4
5

6
7
8

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

K-060
K-062
K-064

PN 16
Water Supply

PN 25
PN 40

Air & Vacuum Air Valve for High Flow


Description

The K-060 series Air & Vacuum Valve discharges air during the
filling or charging of the system and admits air into the system
during system drainage, valve or pump shut-off or at water column
separation.

Applications

- Municipal and industrial water conveyance systems.


- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.
- Water systems with high pressure demands (K-062, K-064).

Operation

The air & vacuum valve discharges air at high flow rates during the
filling of the system and admits air at high flow rates during the
drainage , pump shut-off or at water column separation.
High velocity air will not blow the float shut. Water entry will cause
the sealing of the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air prevents pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air is discharged by the valve.
2. The liquid enters the valve, lifting the float and sealing the valve.
EnC-K060WTR-11 105

When internal pressure falls below atmospheric pressure


(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
orifice.
2. Air will enter the system.

Main Features

- Working pressure range:



K-060 0.2-16 bar

K-062 0.2-25 bar

K-064 0.2-40 bar
- Testing pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: bronze and E.P.D.M. rubber, assures
long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the
international standard DIN 30677-2.

Valve Selection

- Size Range: 1-10 (25mm-250mm) for all models in the series.


- These valves are manufactured with flanged ends to meet any
requested standard.
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Valve coating: baked epoxy coating according to the standard DIN
30677-2.
- Other coatings are available upon request.
- The K-060 series air & vacuum air valve is also available as a
combination air valve for Models D-060, D-060-C, D-062, D-065,
with the addition of an Automatic Air Release valve.
- The K-060-I series air & vacuum valve can be supplied with an
optional In-only check valve attachment, allowing for air intake
only; prevents air discharge.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

K-060

K-060
DIMENSIONS AND WEIGHTS
Nominal

Dimensions mm

Size

Connection

Weight

Orifice Area

220

1 Female

3.8

506.7

220

1 Female

4.8

506.7

1 (25mm) Threaded

132

1 (25mm) Flanged

132

Nominal

Dimensions mm

Size

Kg.

Weight

Orifice Area

Kg.

2 (50mm) Threaded

180

231

10

1960

2 (50mm) Flanged

185

218

10

1960

3 (80mm)

219

272

18

5030

4 (100mm)

262

332

27

7850

6 (150mm)

378

569

77

17662

8 (200mm)

463

664

116

31400

10 (250mm)

586

849

244

49087

mm2

mm2

1"

1
2
3
4
5

1" PARTS LIST AND SPECIFICATION


No. Part

Material

1. Plug

Brass ASTM B124

2. Cover

Ductile Iron ASTM A-536 60-40-18

3. Orifice Seat

Bronze

4. Orifice Seal

E.P.D.M

5. O-Ring

BUNA-N

6. Bolt, Nut & Washer

Steel, Zinc Cobalt Plated

7. Body

Ductile Iron ASTM A-536 60-40-18

8. Float

Polycarbonate / Stainless Stell SAE 304

7
8

2" - 10" PARTS LIST AND SPECIFICATION

2" - 10"

No. Part Material

1. Domed Nut & Washer Stainless Steel SAE 304

2. Screen Cover

2-4 Ductile Iron/ Cast Iron

6-10 Polyethylene / Cast Iron / Sphero Nodular

3. Threaded Rod Stainless Steel SAE 304


4. Screen Stainless Steel SAE 304
5. Cover Ductile Iron ASTM A-536 60-40-18

EnC-K060WTR-11 107

6. Bolt, Nut & Washer Steel, Zinc Cobalt Coated

7. Plug Brass ASTM B124


8. Orifice Seat Bronze

9. Orifice Seal E.P.D.M.

10

10. O-Ring
11. Float

BUNA-N

11

PN16, PN 25 Polycarbonate / Stainless Steel SAE 304

12

PN 40 2"-4" Polycarbonate / Stainless Stell SAE 304


PN 40 6"-10" Stainless Steel

12. Body Ductile Iron ASTM A-536 60-40-18


A

K-060 NS 16 bar
K-062 NS 25 bar
K-064 NS 40 bar

Water Supply

Air & Vacuum Air Valve for High Flow Non Slam
Description

The K-060 NS series Air & Vacuum Valve discharges air during
the filling or charging of the system and admits air into the system
during system drainage, valve or pump shut-off or at water column
separation.

Applications

- Municipal and industrial water conveyance systems.


- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.
- Water systems with high pressure demands (K-062 NS,
K-064 NS ).

Operation

The air & vacuum valve discharges air at high flow rates during the
filling of the system and admits air at high flow rates during the
drainage , pump shut-off or at water column separation.
High velocity air will not blow the float shut. Water entry will cause
the sealing of the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.

EnC-K060NSWTR-11 109

As the system starts to fill, the valve functions according to the


following stages:
1. Entrapped air is discharged by the valve.
2. The liquid enters the valve, lifting the float and sealing the valve.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
orifice.
2. Air will enter the system.

Main Features

- Working pressure range:



K-060 NS 0.2-16 bar

K-062 NS 0.2-25 bar

K-064 NS 0.2-40 bar
- Testing pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- All main flow cross-sections are equal or greater than the nominal
port area.
- Aerodynamic design enables high flow rates of air both at intake
and at discharge.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Special orifice seat design: Stainless steel and E.P.D.M. rubber,
assures long-term maintenance-free operation.
- Screen protected outlet.
- The upper screen is protected with a protective cover.
- FBE coating, both interior & exterior, according to the standard
DIN 30677-2.

Valve Selection

- Size Range: 1-10 (50mm - 250mm) for all models in the series.
- These valves are manufactured with flanged ends to meet any
requested standard.
- The 1", 2 valve is also available with a threaded male BSP/NPT
connection.
- Valve coating: FBE coating according to the standard
DIN 30677-2.
- Other coatings are available upon request.
- The K-060NS series air & vacuum air valve is also available as a
combination air valve for Models D-060 NS, D-060-C NS,
D-062 NS, D-065 NS, with the addition of an Automatic Air
Release valve.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

K-060 NS
Non-Slam Disc

The built- in throttling device on the Non-Slam disc of the D-060 HF


NS Combination Air Valves will allow for the graduated opening and
closing of the disc orifice.
Advantages:
1. The orifice size of the disc can be adjusted to control and throttle
the discharge of air during pipeline filling and during the return of the
water column after separation.
2. The controlled discharge of air will reduce surge effects and provide
for a silent closure of the air valve.
3 .The closure of the orifice can be determined by running a surge
analysis or by a decision taken in the field.
4. The orifice throttling device allows for a wide range of options from
100% open, partially open, partially closed to 100% closed.

K-060 Non-Slam Orifice Data Table


Nominal
Size

Discharge
orifice mm

Total NS
area mm2

NS orifice
mm

Switching
point

Flow at
0.4 bar
m3/h

1 (25 mm)

37.5

12.6

Spring loaded
normally closed

17.5

2 (50mm)

50

63

10

90

3 (80mm)

75

175.4

15

23

240

4 (100mm)

100

476.4

24.5

23

350

6 (150mm)

150

900.6

34

23

600

8 (200mm)

200

1696.9

46.5

20

1850

10 (250mm)

250

1575.7

45

17

2800

K-060 NS

EnC-K060NSWTR-11 111

K-060 NS
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connection

Weight

Orifice Area

Kg.

mm2

1 (25mm) Threaded

243

225

1/8 Female

4.1

506.7

1 (25mm) Flanged

243

225

1/8 Female

5.1

506.7

1" PARTS LIST AND SPECIFICATION


No. Part

Material

1. Plug

Brass ASTM B124

2. One Way Check Valve

Acetal

3. Discharge Outlet

Polypropylene

4. Cover

Ductile Iron ASTM A-536 60-40-18

5. Orifice Seat

Bronze

6. Orifice Seal

E.P.D.M

7. O-Ring

BUNA-N

8. Bolt, Nut & Washer

Steel, Zinc Cobalt Plated

9. Body

Ductile Iron ASTM A-536 60-40-18

10. Float

Polycarbinate / Stainless Stell SAE 304

1
2
3

4
5
6
7
8
9
10

K-060 NS
Nominal
Size

Dimensions mm

Weight

Orifice Area

Kg.

mm2

2 (50mm) Threaded

185

288

12.4

1960

2 (50mm) Flanged

185

273

12.4

1960

3 (80mm)

219

362

19.4

5030

4 (100mm)

262

420

27.3

7850

6 (150mm)

357

659

90.3

17662

8 (200mm)

463

782

138.3

31400

10 (250mm)

586

899

306.8

49087

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Domed Nut & Washer

Stainless Steel SAE 304

2. Screen Cover

2-4
6-10

Ductile Iron / Cast Iron


Polyethylene / Cast Iron / Ductile Iron

3. Threaded Rod

Stainless Steel SAE 304

4. Screen

Stainless Steel SAE 304

5. Cover
6. Ring
2-4

6-10
7. Flap
2-4

Ductile Iron ASTM A-536 60-40-18


Stainless Steel SAE 316
Steel DIN ST.37
Stainless Steel SAE 316

Cast Iron ASTM A-48 CL.35B / Ductile Iron

6-10

8. Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

9. Orifice Seat

Bronze

10. Orifice Seal

E.P.D.M.

11. O-Ring

BUNA-N

12. Float

Polycarbonate / Stainless Steel

13. Body

Ductile Iron ASTM A-536 60-40-18

3
4
5
6
7

8
9

EnC-K060NSWTR-11 113

10
11
12
13

K-060 NS
Operation in Rapid Filling of the Pipeline:

1. When water, rapidly filling the pipe line, pushes the air out
through the Air Valve, a differential air pressure is created across
the valve orifice.

2. When this differential pressure reaches a prefixed level (usually it


will be prefixed at 0.02 - 0.03 bar) the orifice disc will close.
3. Air will continue to come out through the small orifice disc - until
all the air will be exhausted and water will reach the kinetic float.
This double stage kinetic air discharge prevents the slam effect and
therefore suppresses water hammer.

4. When water reaches the kinetic float, it lifts it up, closing the
kinetic orifice and completing the kinetic cycle.
5. The vented Check Valve Orifice Disc will come back to its
normal open position.

6. When water is drained out of the pipe line, the resulting pressure
drop lets the kinetic float fall down, opening the orifice fully for
intake of high volume of air into the line.

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

S-014
S-015
S-016

PN 40
Water Supply

PN 40
PN 64

Automatic Air Release Valve for High-Pressure Systems


Description

The S-014, S-015, S-016 series automatic air release valve releases
accumulated air from the system while it is under pressure.
The presence of air in a water system can reduce the effective
cross sectional flow area resulting in increased head loss and
flow. Unwanted air may also cause water hammer and metering
inaccuracies, while hastening corrosion.

Applications

- On high-pressure pumps.
- On high-pressure delivery pipelines.

Operation

EnC-S016WTR-11 115

The automatic air release valve releases entrapped air from


pressurized systems.
Pockets of accumulated air may cause the following destructive
phenomena:
- Impediment of effective flow and hydraulic conductivity of the
system along with a throttling effect as would a partially closed
valve. In extreme cases this will cause complete flow stoppage.
- Accelerate cavitation damages.
- High- pressure surges.
- Accelerate corrosion.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
The valve functions while the system is under pressure,
according to the following stages:
1. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
2. The float descends, unsealing the rolling seal. The automatic air
release orifice opens and the accumulated air is released.
3. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
Note: Automatic air release valves are designed to release air as
it accumulates in pressurized systems. They are not normally
recommended for vacuum protection or for discharging large
volumes of air, because of their inherently small orifices. For this
purpose, air & vacuum valves are recommended as they have much
larger orifices.
However, air release valves will permit air to enter the system under
vacuum conditions. If this is not desirable, specify the one-way out
check valve.

Main Features

- Working pressure range: S-014: 0.2 - 40 bar



S-015: 0.2 - 25 bar / 0.2 - 40 bar

S-016: 0.2 - 64 bar
- Test pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
-All operating parts are made of specially selected corrosion-resistant
materials.
- A.R.I. patented rolling seal mechanism:
Dramatically reduces the possibility of obstruction by debris.
One size orifice for a wide pressure range up to 64 bar.
Self-cleaning mechanism.
- Lightweight, small dimensions, simple and reliable structure.

Valve Selection

- S-014 (40 bar), S-015 (25 / 40 bar), S-016 (64 bar) are available in
3/4, 1, male threaded BSP and NPT connections / flanged.
- Standard metal body - FBE coating according to the standard
DIN 30677-2.
- Other coatings are available upon request.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

S-014 / S-016

DIMENSIONS AND WEIGHT


Dimensions mm
A

197

295

Connection

Weight

Orifice Area

1/2 BSP Female

13

15

Kg.

mm2

A
1
2

C
PARTS LIST AND SPECIFICATION
No.

3
4
5

Part

Material

1.

Orifice Cover

Polypropylene

2.

Nut

Brass ASTM B124

3.

O-Ring

BUNA-N

4.

Cover

Cast Steel ASTM A216 WCB

5.

Orifice

Reinforced Nylon

6.

Rollpin

Stainless Steel SAE 304

7.

Rolling Seal

E.P.D.M.

8.

O-Ring

BUNA-N

9.

Bolt and Nut

Steel Zinc Cobalt Plated

10.

Lever

Reinforced Nylon

12

11.

Rollpin

Stainless Steel SAE 304

13

12.

Float

Polycarbonate / Stainless Steel


SAE 316L

13.

Body

Cast Steel ASTM A216 WCB

14.

Adapter

Brass ASTM B124

6
7

8
9
10
11

14

S-015

DIMENSIONS AND WEIGHT


Dimensions mm
A

158

292

Connection

Weight

Orifice Area

1/2 BSP Female

5.4

15

Kg.

mm2

A
C

1
2

PARTS LIST AND SPECIFICATION


No.

3
4

EnC-S016WTR-11 117

Part

Material

1.

Discharge Outlet

PVC

2.

Rollpin

Stainless Steel SAE 304

3.

O-RING

BUNA-N

4.

Orifice

Reinforced Nylon

5.

Cover

Ductile Iron ASTM A536 60-40-18

6.

Rollpin

Stainless Steel SAE 304

7.

Rolling Seal

E.P.D.M.

10

8.

Lever

Reinforced Nylon

9.

Rollpin

Stainless Steel SAE 304

10.

O-RING

BUNA-N

11.

Bolt, Nut & Washer

Steel, Zinc Cobalt Coated

13

12.

Float

Polycarbonate / Stainless Steel SAE 316

14

13.

Body

Ductile Iron ASTM A536 60-40-18

14.

Adapter

Brass ASTM B124

11
12

S-050
S-050-C
S-052

PN 16
Water Supply

PN 16

PN 25

Automatic Air Release Valve


Description

The S-050 series Automatic Air Release Valve releases accumulated


air from the system while it is under pressure. The presence of air
in a water system can reduce the effective cross sectional flow area
resulting in increased head loss and deceased flow. Unwanted air
may also cause water hammer and metering inaccuracies, while
hastening corrosion. In spite of its compact and light weight
structure, the S-050 series Automatic Air Release Valve has a
12mm orifice that enables it to release air at high flow rates and is
not exposed to obstruction by debris.

Applications

- On most types of pumps.


- After filters, pressure reducers and fertilizer injection systems.
- On heads of landscape systems.
S-050-C S-052 additionl applications:
- Water pipelines vulnerable to vandalism and/or water theft.
- Water systems found in remote areas.

Operation

EnC-S050WTR-11 119

The automatic air release valve releases entrapped air from


pressurized systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
The valve functions while the system is under pressure,
according to the following stages:
1. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
2. The float descends, unsealing the rolling seal. The automatic air
release orifice opens and the accumulated air is released.
3. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
Note: Automatic air release valves are designed to release air as it
accumulates at peaks in pressurized systems. They are not normally

recommended for vacuum protection or for discharging large


volumes of air, because of their inherently small orifices. For this
purpose, air & vacuum valves are recommended as they have much
larger orifices.
However, automatic air release valves will permit air to enter the
system under vacuum conditions. If this is not desirable, specify the
one-way out check valve.

Main Features

- Working pressure range:


S-050 0.2 - 16 bar
S-050-C 0.2 - 16 bar
S-052 0.2 - 25 bar
- Test pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The body is made of high strength composite materials and all
operating parts are made of specially selected corrosion- resistant
materials.
- The larger than usual orifice enables it to release air at higher flow
rates than other automatic air release valves of its kind.
- The enlarged orifice is less exposed to obstruction by debris.
- The valves rolling seal mechanism design is less sensitive to
different pressures than a direct float seal, thus enabling a one size
orifice for a wide pressure range (from 0.2 up to 25 bar).
- Lightweight, simple and reliable structure.
- A discharge outlet enables removal of excess fluids.

Valve Selection

- Available in male threaded sizes: 1/2, 3/4, 1 - BSP / NPT


- S-050 is pressure rated for 16 bar.
- S-050-C vandalism protected by a metal shell covering the air
release component, pressure rated for 16 bar.
- S-052 vandalism protected by a metal shell covering the air release
component, pressure rated for 25 bar.
- SG-10 For low pressures (0.2-10 bar)
- S-050 LP For low pressures (0.05-6 bar)
- S-050 B With a brass base (0.2-16 bar)
- S-050 V, S-050-C-V Vacuum check valve - Available as a
valve that will only release air from the system and will not admit
air to the system when negative pressure conditions occur. This
characteristic is obtained by adding a check valve to the air outlet.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

S-050 / S-050-C / S-052


S-050 / S-050 B

A
2
3

S-050

S-050 B

S-050-C

DIMENSIONS AND WEIGHTS


Model

Dimensions mm
A

Connection
C

Weight
Kg.

Orifice Area

S-050

87

143

1/8 BSP Female

0.3

12

87

143

1/8 BSP Female

0.65

12

S-050-C

85

148

1/8 BSP Female

1.65

12

S-052

85

148

1/8 BSP Female

1.65

PARTS LIST AND SPECIFICATION


Part

1.

Shell
Cast Iron ASTM A-48 CL35B

S-052

Ductile Iron ASTM A-536-60-40-18

2.

Body

Reinforced Nylon

3.

Discharge Outlet
S-050

Polypropylene

S-050-C/S-052

Brass ASTM B-124

4.

Rolling Seal

E.P.D.M.

5.

Clamping Stem

Reinforced Nylon

6.

Float

Foamed Polypropylene

7.

O-Ring

BUNA-N

8.

Base

6
7
8
9

S-050-C / S-052

Material

S-050-C

9.

mm2

S-050 B

No.

S-052

S-050

Reinforced Nylon / Brass ASTM B-124

S-050-C/S-052

Brass ASTM B-124

Strainer

Nylon

A
1

2
3
4

5
6
7
8
9

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

S-050 LP

Water Supply

PN 6

Automatic Air Release Valve for Low Pressure


What is a low pressure air valve?

The low pressure air valve sealing mechanism is built with a very
soft and sensitive seal. On one hand, it enables the full and effective
discharge of air and, on the other hand, the air valve will close and
seal tightly when water fills the valve, even if the water pressure is
particularly low. Most other air valves are built so that it takes a
higher minimum sealing pressure to effectively seal the valve. The
ARI air valve requires a minimum water pressure of just 0.2 bar
(3psi) to effectively seal. Low pressure air valves are designed to
prevent water leaks through the discharge orifice of the valv

Description

The S-050 LP series Automatic Air Release Valve releases


accumulated air from the system while it is under pressure. The
presence of air in a water system can reduce the effective cross
sectional flow area resulting in increased head loss and deceased
flow. Unwanted air may also cause water hammer and metering
inaccuracies, while hastening corrosion. In spite of its compact and
light weight structure, the S-050 LP series Automatic Air Release
Valve has a 12mm orifice that enables it to release air at high flow
rates and is not exposed to obstruction by debris.

Applications

- On most types of pumps.


- After filters, pressure reducers and fertilizer injection systems.
- On heads of landscape systems.

Operation

EnC-S050LPWTR-11 121

The automatic air release valve releases entrapped air from


pressurized systems.
Pockets of accumulated air may cause the following destructive
phenomena:
- Impediment of effective flow and hydraulic conductivity of the
system along with a throttling effect as would a partially closed
valve. In extreme cases this will cause complete flow stoppage.
- Accelerate cavitation damages.
- High- pressure surges.
- Accelerate corrosion.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
The valve functions while the system is under pressure,
according to the following stages:
1. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the

valves body.
2. The float descends, unsealing the rolling seal. The automatic air
release orifice opens and the accumulated air is released.
3. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
Note: Automatic air release valves are designed to release air as it
accumulates at peaks in pressurized systems. They are not normally
recommended for vacuum protection or for discharging large
volumes of air, because of their inherently small orifices. For this
purpose, air & vacuum valves are recommended as they have much
larger orifices.
However, automatic air release valves will permit air to re-enter the
system under vacuum conditions. If this is not desirable, specify the
one-way out check valve.

Main Features

- Working pressure range: 0.05 - 6 bar


- Test pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The body is made of high strength composite materials and all
operating parts are made of specially selected corrosion- resistant
materials.
- The larger than usual orifice enables it to release air at higher flow
rates than other automatic air release valves of its kind.
- The enlarged orifice is less exposed to obstruction by debris.
- The valves rolling seal mechanism design is less sensitive to
different pressures than a direct float seal, thus enabling a one size
orifice for a wide pressure range (from 0.05 up to 6 bar).
- Lightweight, simple and reliable structure.
- A discharge outlet enables removal of excess fluids.

Valve Selection

- Available in male threaded sizes: 1/2, 3/4, 1 - BSP / NPT


- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

S-050 LP
DIMENSIONS AND WEIGHTS
Model
1,1/2, 3/4

Dimensions mm

87

143

1/8

Weight

Orifice Area

0.3

12

Kg.

mm2

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Body

Polypropylene

A
2

/ Reinforced Nylon
3.

Discharge Outlet

Polypropylene

4.

Rolling Seal

Silicone

5.

Clamping Stem

Reinforced Nylon
/ Polypropylene

6.

Float

Foamed Polypropylene

7.

O-Ring

BUNA-N

8.

Base

Polypropylene

/ Reinforced Nylon
9.

Strainer

Nylon

6
7
8
9

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

NR-020

Water Supply

PN 16

Wafer Style Check Valve


Description

The NR-020 Check Valve is compatible for installation on


horizontal pumps and boosters, in order to prevent the return
flow of water to its source and to provide quiet closing and total
sealing of the sealing face. The check valve is designed for free flow
of water without interference and minimal head loss. The check
valve is made from composite materials (diameters of 3-6) and an
anodized aluminum alloy (8 diameter) .

Applications

After pumps/boosters.
Foot check valve for pumping from ponds.
Filtration systems.
Swimming pools (for 8" models, additional modifications are
required for this application).

Main Features

Working pressures: up to 16 bar.


Maximum working temperature:60C.
Maximum intermittent temperature: 90C.
In the 3-6 diameter models, the valve body and disc are made
from composite materials which are resistant to highly abrasive
conditions and durable in environments using corrosive liquids such
as sea water, brine and chlorine.
In the 8" diameter models, the valve is made from an anodized
aluminum alloy. Use in corrosive liquid environments such as sea
water, brine and chlorine, require an additional modification to the
check valve and needs to be specified.
Metal parts are made from SAE 304 stainless steel (SAE 316
stainless steel is also available upon request).
The valve is supplied together with seals for flange to flange
installation.
The spring assembly mechanism is outside of the flow cross-section
and can be replaced without removing the valve from the line.

Options

The valve is available in diameters: 3, 4, 6, 8.


The valve is available with a limit switch that transmits a contact
signal at flow start or its discontinuance (pump safety mechanism),
Model NR-020-LS.
The valve is available with a strainer added as Check Valve,
Model NR-020-FV (foot valve).
The valve is also available for pressures of up to 10 bar,
Model NR-010.
For maximum compatibility, it is recommended to specify the
composition of the liquids and requirements of the system.
For check valve selection and placement, use the recommendation
page or contact our customer service department.
When ordering, please specify model, size, working pressure, flange
standards and special coatings required.

EnC-NR020WTR-11 123

NR-020

NR-020

NR-020 3-6
PARTS LIST AND SPECIFICATION

1
2

No. Part

Material

1.

Spring Chamber

Reinforced Nylon

2.

Spring

Stainless Steel SAE 302

3. O-Ring

BUNA-N

4.

Spring Seat

Acetal

5.

Indicator Stem Bushing Teflon

6.

Flap Shaft

Stainless Steel SAE 316

7.

Roller Shaft

Stainless Steel SAE 316

8.

Roller

Reinforced Nylon

9.

Flap

Reinforced Nylon

10.

Flap Seal

E.P.D.M.

8
9
10

11

11. Cover Bolts

Stainless Steel SAE 304

12. Disc

Stainless Steel SAE 304

13. Bolts

Stainless Steel SAE 304

14.

Cover Seal

E.P.D.M.

14

15.

Body

Reinforced Nylon

16.

Cover

Reinforced Nylon

15

17. Flange Seals

12
13

16

E.P.D.M.

17

NR-020 8
PARTS LIST AND SPECIFICATION
No. Part

Material

1.

Spring Chamber

Reinforced Nylon

2.

Spring

Stainless Steel SAE 302

3. O-Ring

BUNA-N

4.

Acetal

Spring Seat

1
2
3
4
5
6

C
B

5. Plug

Brass

6. O-Ring

BUNA-N

7.

Roller

Reinforced Nylon

8.

Shaft

Stainless Steel SAE 304

9.

Flap Shaft

Stainless Steel SAE 303

10

10. Flap

Aluminum

11.

O-Ring

BUNA-N

11

12.

Body

Aluminum

12

NR-020

NR-020 LS

NR-020 LS 3-6 WITH LIMIT SWITCH


PARTS LIST AND SPECIFICATION
No. Part

1
2
3

Material

1.

Limit Switch

2.

Plastic Cover

Reinforced Nylon

3.

O-Ring

E.P.D.M.

4.

Indicator Stem Bushing Teflon

5.

Nut

Reinforced Nylon

6.

Spring Chamber

Reinforced Nylon

7.

Spring

Stainless Steel SAE 302

8.

Position Indicator Stem Stainless Steel SAE 316

9.

O-Ring

4
5
6
7
8
9
10
11
12

BUNA-N

13

10. Spring Seat

Acetal

11. Shaft Bushing

Stainless Steel SAE 303

12. Shaft

Stainless Steel SAE 316

15

13. Flap Shaft

Stainless Steel SAE 316

16

14. Roller

Reinforced Nylon

15. Flap

Reinforced Nylon

17

16. Flap Seal

E.P.D.M.

17. Cover Bolts

Stainless Steel SAE 304

18. Disc

Stainless Steel SAE 304

19. Disc Bolts

Stainless Steel SAE 304

20. Cover Seal

E.P.D.M.

21. Body

Reinforced Nylon

22. Cover

Reinforced Nylon

23. Flange Seals

E.P.D.M.

14

18
19
20
21
22
23

A
EnC-NR020WTR-11 125

NR-020

NR-020 FV

DIMENSIONS AND WEIGHTS


Nominal

Dimensions mm

Weight Kg.

Size

NR-020

NR-020 LS

NR-020FV

3 (50 mm)

85

148

204

286

207

1.15

1.5

1.5

4 (80 mm)

93

165

214

296

230

1.6

2.0

2.0

6 (80 mm)

115

228

311

393

296

3.15

3.6

4.0

8 (80 mm)

127

273

342

428

339

6.5

6.9

7.2

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

NR-040
NR-044

PN 16
PN 40

NR-042
NR-064

PN 25

Water Supply

PN 64

Check Valve with Removable Cover

Description

The NR-040 series Swing-Type Check Valve allows for onedirectional flow and prevents the return flow of the liquid to its
source.
The check valve is designed with a removable top cover which allows
for cleaning and maintenance of the check valve without the need to
remove it from the pipeline.
The disc is attached to the check valve body with the aid of an arm.
The check valve seals with the closure of the disc against the sealing
ring which is located at the opening of the check valve body.

Applications

- Pump stations for potable water and wastewater


- Filtration systems
- Service line connections to the main line

Operation

- Liquid flow through the check valve raises the disc to its open
position and allows for the flow of liquids to the pipeline.
- Two Possible Situations for Disc Closure
1. Regular quiet closure of the disc.
2. Closure during the return flow of the water column, a situation
that can cause slam of the disc and damage to the check valve.
- In order to prevent this destructive phenomenon, it is
recommended to install a counterweight on the shaft of the check
valve. With this addition, the disc will close at the point of water
flow cessation and before the water column returns. The returning
wave will impact on a closed disc and the acceleration of the disc
closure will result in a minimal slam effect.
- Another option is to install a hydraulic piston to control the
closure of the disc.

Main Features

- Maximum working temperature: 60 C.

- Maximum intermittent temperature: 90 C.


- Surge-resistant cast iron body.
- Bronze or ductile iron disc with natural rubber flap seal, seals at
low pressures and eliminates wear and tear of the flap.
- Corrosion-resistant inner parts ensure long term service under
adverse conditions.
- Fusion-bonded epoxy coating according to standard
DIN 30677-2.
- Removable top cover allows for easy cleaning, maintenance, and
seat replacement and eliminates the need to remove the valve from
the system.
- Can be installed in either a horizontal or vertical position
(vertically, only when the flow rate is in an upward direction and a
counterweight is installed).
- Stainless steel extended shaft on both sides of the valve body.

Valve Selection

- Size range 3"-40"


- Available in pressure ratings of 16 bar (Cast Iron Body / Ductile
Iron), 25 bar (Ductile Iron Body), 40 and 64 bar (Cast Steel Body).
- Flanges are available in BS/ISO/ANSI standards.
- Can be adapted to various types of liquid upon request.
- Options:
A. Bronze on bronze or stainless steel on stainless steel disc and
seat seal for adverse working conditions.
B. Available with enamel-coated body or stainless steel body.
C. Additional counterweight for slam protection and/or
NR-040 LS electric limit switch indicator for transmitting a flow/
no flow signal.
D. Hydraulic Controlled Check Valve NR-040-HC is available.
-For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

EnC-NR040WTR-11 127

NR-040
PARTS LIST AND SPECIFICATIONS
No. Part

Material

1.

Counterweight

Cast Iron / Steel

2.

Lifting Ring

Steel

3.

Cover

Ductile Iron ASTM A-536-50-40-18

4.

Bolt, Nut & Washer Steel Zinc Cobalt Coated

5.

Cover O-Ring

BUNA-N

6.

Body

Cast Iron / Ductile Iron

7.

Cotter Pin

Stainless Steel SAE 304

8.

Arm Pin

Stainless Steel SAE 303

9.

Arm

14

15

16

17

18

19

20

Bronze ASTM B-62 / Ductile Iron

10. Disc

Bronze ASTM B-62 + Natural & Synthetic Rubber

/ Ductile Iron + Natural & Synthetic Rubber

11. Bolt

Stainless Steel SAE 304

12. Sealing Ring

Bronze ASTM B-62

/ Stainless Steel on Bronze ASTM B-62

/ Stainless Steel on Stainless Steel

13. Stopper

Natural & Synthetic Rubber

14. Shaft

Stainless Steel SAE 303

15. Plug Bolt

Stainless Steel SAE 304

16. Plug O-Ring

BUNA-N

17.

Stainless Steel

Bearing

18. Spacer

Brass ASTM B-124

19. Disc Arm Key

Stainless Steel SAE 303

20. Plug

Brass ASTM B-124

D
1
2
3

DIMENSIONS AND WEIGHTS

4
5

Nominal Dimensions mm
Weight
Size
A B C D Kg.
3 (80 mm) 242 252 316 300 20.0
4 (100 mm) 262 280 347 320 28.5
6 (150 mm) 356 360 505 400 57.0
8 (200 mm) 420 453 638 500 101.0

6
7

9
10

10 (250 mm) 479 537 670 550 166.0

11

12 (300 mm) 553 622 727 600 242.5


14 (350 mm) 838 701 862 700 352.0

12

16 (400 mm) 760 734 910 700 364.0

13

18 (450 mm)

978

850

1210

860

756.0

20 (500 mm)

865

892

1110

1000

640.0

24 (550 mm) 1295 1090 1320 1120 1239.0


28 (650 mm) 1448 1312 1700 1310 1670.0
32 (750 mm) 1850 1374 1783 1300 2200.0
36 (800 mm) 1956 1504 1985 1410 2500.0
40 (900 mm) 2250 1680 2090 1500 3350.0
A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988
A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

HCCV

Water Supply

PN 16

Hydraulically Controlled Check Valve


Full Hydraulic Transient Control
Description

The A.R.I. Hydraulically Controlled Check Valve (HCCV) is a


multipurpose damping device for pump discharge control. The valve
functions as a one-directional Flow Control Valve, a Non-Return
Valve and an internal Surge Anticipation Valve, all in one unit.
The hydraulically controlled check valve consists of two major parts:
1. A single shaft check valve.
2. A hydraulic control system.
The hydraulic control system is mounted on the check valve and
installed at the pump station. The HCCV hydraulically controls
the opening and closing of the check valve disc. The valve prevents
slam subsequent to pump shut-down, reduces water hammer while
switching the pump on and off and alleviates surges resulting from a
power failure at the pump station.

1. Initial fast closing of the disk to 80% of its fully closed position
controllable from 2 to 10 seconds.
2. Secondary, damping stage, from 80% to fully closed
controllable from 5 to 200 seconds.
Supplemental fine-tuning by cam adjustments provides added
flexibility of the operation.
- Timing adjustments can be easily made on-site.
- Smooth non-slam closure of the disc.
- Face to face dimensions according to ISO and EN standards.
- Metallic removable seals for easy servicing.
- Sealing seats are corrosion and wear resistant.
- Hydraulic accumulator provides the energy to close the disc in the
event of a power failure.
- Low maintenance, long working life.

Applications

Specifications

- Pump Stations - at potable water, wastewater, desalination and


industrial processing plants.

Operation

The HCCV consists of a self-contained unit operated both by the


water flow generated by the main pump and by an electricallypowered hydraulic booster. The hydraulic control system manages
the opening and closing phases of the check valve operation. The
gradual opening phase is controlled at a predetermined rate. The
angle and the timing of the two-stage closing phase can be adjusted
to meet the flow regimen of the pipeline.

Main Features
EnC-HCCVWTR-11 129

- Innovatively designed to specifically control surge.


- The HCCV acts as an internal surge relief valve.
- Damping characteristics can be synchronized to match the
dynamic behavior of the surge waves in the system and can be
adapted to the transient conditions in the pipeline.
- Affords efficient pump station and pipeline protection.
- Hydraulically-opened full flow passage greatly reduces head losses
and lowers energy costs.
- Controlled closing cycle remains fully functional, even during
power failure.
- Opening cycle of the A.R.I. HCCV is set to prevent surge at pump
start-up.
- Closing cycle of the A.R.I. HCCV is fully controlled and
adjustable for the two principal phases:

- Nominal Size: 400 mm 900 mm


- Pressure Rating: 6 bar, 10 bar, 16 bar.
- Max. Working Temp.: 70C
- Electric Oil Pump: 3 Phase - 220 V, 5HP
- Electric Power Control: 24 DVC

Options

- Higher back-pressure application.


- Horizontal or Vertical Installation, upon request - for confined
spaces.
- Special internal/external coatings for use with corrosive liquids.

HCCV
Typical Power Failure Closing
Characteristics

The first fast closing angle (%) and time (t1) are continuously
adjustable depending on the hydraulic characteristicsof the line.The
second damping closure is adjusted to include the surge wave return
time: 2L/c.This allows a part of the surge wave to be absorbed by the
HCCV and pump resistance.
Example of three closing regimes

HCCV
NR-040 HC PARTS LIST AND
SPECIFICATION
No.

Part

Material

1.

Body

Ductile Iron

2.

Shaft

St. St. 17-4 PH

3.

Hydraulic Piston

4.

Accumulator

5.

Logic Block

6.

Oil Tank

7.

Electric Motor

8.

Operator Arm

9.

Limit Switch

10.

Hydraulic Valve

11.

Mechanical Interface

ASTM A536 60-40-18

Steel
Steel

Ductile Iron
ASTM A536 60-40-18

NR-050 HC PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Body

2.

Shaft
Hydraulic Piston
Accumulator
Logic Block
Oil Tank
Electric Motor
Mechanical Interface

Ductile Iron A
STM A536 60-40-18
St. St. SAE 431

3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

Limit Switch
Hydraulic Valve
Counterweights
Operator Arm
Control Box

Steel
Ductile Iron
ASTM A536 60-40-18

Steel
Steel

EnC-HCCVWTR-11 131
12

11

GV R 31

Water Supply

Rising Stem Gate Valve


Applications

- Wedge gate seal type - the seals can automatically compensate cach
other and maintain tight sealing even after wear and tear.
- The shaft seal utilizes V-shaped packing for better seal adjusting
accuracy and longer durability.
- The internal chamber of the body adopts different coatings to meet
the requirements of various working conditions.
- Some valves are equipped with a by-pass valve for higher efficiency
in opening of the valve.
- Can be equipped with hand wheel or electric actuator to meet
different operating requirements.
- The valve outline is of streamlined design and precision casting.

- Water Supply Systems


- Sewage Treatment
- Chemical Industry

Main Features

- Nominal Diameter: DN 450-DN 2000.


- Temperature: up to 70C.
- Operating Pressure: up to 1.6MPa.
- Medium: water, sewage.
- High temperature and pressure available on request.

inc

DN

mm

D2

n-d

1MPa 1.6MPa 1MPa 1.6MPa 1MPa 1.6MPa

L1

H max.

Weight kg.

1MPa 1.6MPa 1MPa 1.6MPa 1MPa 1.6MPa

18

450

615

640

565

585

20-28

20-31

432

2093

2120

608

768

20

500

670

715

620

650

20-28

20-34

457

2374

2410

807

880

24

600

780

840

725

770

20-31

20-37

508

2745

2790

1175

1480

28

700

895

910

840

840

24-31

24-37

610

888

888

3102

3120

2242

3033

30

750

955

970

895

895

24-34

24-40

610

923

923

3285

3308

2690

3620

EnC-GVR31WTR-11 133

32

800

1015

1025

950

950

24-34

24-41

660

923

923

3395

3410

2989

4088

36

900

1115

1125

1050

1050

28-34

28-41

711

1002

1002

3923

3950

3840

4510

40

1000

1230

1255

1160

1170

28-37

28-44

811

1056

1100

4370

4410

4550

5322

48

1200

1455

1485

1380

1390

32-41

32-50

1015

1220

1220

5106

5150

6718

7760

56

1400

1675

1685

1590

1590

36-44

36-49

1080

1312

1312

5900

6060

9075

12032

64

1600

1915

1930

1820

1820

40-49

40-56

1300

1550

1550

6700

6820

14216

17360

72

1800

2115

2130

2020

2020

44-49

44-56

1500

1700

1700

7570

7630

22122

26470

80

2000

2325

2345

2230

2230

48-49

48-62

1675

1850

1850

8280

8420

29380

34120

GV R 31
PARTS LIST AND SPECIFICATIONS
No. Part

Material

1.

Gear Box Assembly

2.

Drive Support Ductile Iron GGG50

3.

Packing Gland Ductile Iron GG25

4.

Packing Elastomer with Fabric Insertion

5.

Bonnet Ductile Iron GGG50

7.

Stem Stainless Steel SAE 431

6.

Lifting Screw Steel 45

8.

Body Ductile Iron GGG50

9.

Stem Nut Bronze

10. Gate Ductile Iron GGG50


11. Bypass Gate Valve Assembly
12. Bypass Bent Pipe Ductile Iron GGG50
13. Gate Seal Ring Stainless Steel SAE 304
14. Guide Groove Stainless Steel SAE 304
15. Body Seal Ring Stainless Steel SAE 316

1
2
3
4
5
6
7
8
9
10

15

13

14

12

11

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

GV NR 31

Water Supply

Non-Rising Stem Gate Valve


Applications

other and maintain tight sealing even after wear and tear.
- The seals are a combination of both cast bronze and cast
manganese brass for good wear resistance and long service life.
- The shaft seal utilizes V-shaped packing for better seal adjusting
accuracy and longer durability.
- The internal chamber of the body adopts different coatings to meet
the requirements of various working conditions.
- Some valves are equipped with a by-pass valve for higher efficiency
in opening of the valve.
- Can be equipped with hand wheel or electric actuator to meet
different operating requirements.
- The valve outline is of streamlined design and precision casting.

- Water Supply Systems


- Sewage Treatment
- Chemical Industry

Main Features

- Nominal Diameter: DN 100-DN 2000.


- Temperature: up to 120C.
- Operating Pressure: up to 1.6MPa.
- Medium: water, steam, sewage, seawater.
- High temperature and pressure available on request.
- Wedge gate seal type - the seals can automatically compensate cach

DIMENSIONS AND WEIGHTS


DN
D
D1
n-d
L
L1
Hmax
Approx. Wt.

(w.o. E.A.)
mm
1.0 1.6 1.0 1.6 1.0 1.6 1.0 1.6 1.0 1.6 1.0 1.6

450

615 640 565 585 20-28


20-31 432 -

- 1167
1177 584 744


500

670 715 620 650 20-28


20-34 457 -

- 1292
1326 801 849


600

780 840 725 770 20-31 20-37 508

- 1443 1502 1111 1348


700

895 910 840 840 24-31 24-37 610 888 888 2058 2143 2179 2970


800

1015 1025 950 950 24-34 24-40 660 923 923 2178 2272 2894 4058

EnC-GVNR31WTR-11 135


900

1115 1125 1050 1050 28=34 28-40 711 1002 1002 2412 2487 3713 4235

1000

1230 1255 1160 1170 28=37 28-43 811 1056 1100 2604 2719 4343 4406

1200

1455 1485 1380 1390 32-40 32-49 1015 1223 1250 2983 3146 6412 6512

1400

1675 - 1590 - 36-43 - 1080


1312 - 3332 - 8747 -

1600

1915 - 1820 - 40-49 - 1300


1550 - 3771 - 13226 -

1800

2115 - 2020 - 44-49 - 1500


1700 - 4126 - 19752 -

2000

2325 - 2230 - 48-49 - 1675


1850 - 4481 - 26400 -

GV NR 31
PARTS LIST AND SPECIFICATIONS
No. Part

Material

1.

Body

Ductile Iron

2.

Body Seal Ring

C95500 / E.P.D.M.

3.

Gate

Ductile Iron

4.

Gate Seal Ring

C83600 / E.P.D.M.

5. Stem

431

6. Gasket

NBR

7. Bolt

Steel

8.

Bonnet

Ductile Iron

9.

Yoke

Ductile Iron

10.

Packing

PTFE

11. Pressure Cap

Ductile Iron

12. Hand Wheel

Ductile Iron

13.

Stem Nut

C95500

14.

Reduction Gear

* Option: Hand-Wheel on the side

12
14

9
11
10
5

8
6
13
4
3
2
1

D
A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988
A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

RP-500

Water Supply

PN 10

Backflow Preventer
Description

The RP-500 Backflow Preventer is designed to supply maximum


protection against backflow caused by negative pressure or
backpressure. Backflow may cause infiltration of chemicals,
fertilizers and/or other pollutants into potable water systems. The
RP-500 is reliable and easily maintained, without the need for
special tools.
The RP-500 is built with two independent, easily replaceable
capsulated spring-loaded check valves. A revolutionary, internal
Reduced Pressure Zone, located between the check valves, ensures
protection and reliable performance of the relief valve.

Applications

- Chemical and fertilizer systems in landscape and agriculture.


- Swimming pools
- Dairies and poultry coops

Operation

EnC-RP500WTR-11 137

During normal flow, the two check valves open to supply water
downstream. The Relief Valve is power-activated by upstream
pressure and is kept shut by a diaphragm, through the internal
control system.
In the zone, the area between the check valves, pressure is
maintained at approximately 0.43 bar lower than the water supply
pressure. The Outlet Check Valve is spring-loaded to maintain a
minimum pressure decrease of 0.07 bar.
When negative pressure or sub-atmospheric conditions occur, the
Inlet Check Valve closes to prevent backflow. If the Outlet Check
Valve fails, the pressure between the two check valves rises, opening
the Relief Valve and releasing the water to the atmosphere.
The Relief Valve operates on differential pressure. Supply pressure
on the upstream side of the Inlet Check Valve acts against the
diaphragm to close the Relief Valve during normal operation. In the
event of backpressure or backsiphonage, the Relief Valve will open
to maintain the pressure in the zone at 0.14 bar less than the inlet
pressure.
Note: If water continues to drain from the Relief Valve, check the
Troubleshooting section for probable causes and solutions.

Main Features, Advantages and Benefits

- Working Pressure: 10 bar.


- Sizes: 1/2, 3/4, 1,1 , 1 , 2.
- Temp: 0.5 to 45 C.
- Made of composite plastic material: resistant to corrosion, scaling,
fertilizers, herbicides, insecticides, etc.

- Internal control system ensures reliability and safety.


- Easy and quick installation.
- Economical to operate.
- Lightweight.
- UV resistant.
- Low Head-Loss.
- Variety of installation options.
- Long working life with easy maintenance.
The ARI RP-500 is approved by the following Standards authorities:
ASSE 1013, AWWA C511, NSF61, Watermark (Australia)
AS2845.1 ACS (France) Approved by the Foundation for Cross
Connection Control and Hydraulic Research at the University of
Southern California, Listed to Uniform Plumbing Code

Installation

A. Install the RP-500 Backflow Preventer in a location accessible


to periodic field testing and maintenance. Mount the RP-500 in
a horizontal position with adequate clearance from walls and/ or
obstructions. A 30 cm. to 84 cm. clearance is needed between the
lowest portion of the device and floor.
B. Adequate drainage is needed for discharge. A Drainage Funnel is
provided so the discharge may be piped away.
NOTE: Never place the RP-500 where it may become submerged
in standing water.
C. Before installing the RP-500, thoroughly flush all upstream
piping to remove debris.
D. When the shut-off valves are supplied separately, install them
with a Test Cock on the Inlet Shutoff Valve.
E. It is recommended that a Y strainer be installed before the inlet
of the RP-500 to prevent debris from entering the device.
F. After installing the assembly, close the Outlet Shut-off Valve,
pressurize the RP-500 and release the air through Test Cock #4.
Then, open the Outlet Shut-off Valve.

Recommendations

Do not install in areas subject to extended periods of freezing


temperatures.
The product must be protected from excessive pressure increases,
which are caused by thermal expansion or water hammer and can
damage the valve.
DO NOT USE ANY PIPE DOPE, OIL GREASE OR
SOLVENT ON ANY PARTS unless instructed to do so.
Parts should fit together freely. Do not force parts to fit.

RP-500
Maintenance Instructions

A. Disassembly - RP 500.
1.Close the Outlet Shut-off Valve and then close Inlet Shut-off
Valve.
2.Release pressure from the assembly by opening Test Cocks 2, 3
and 4.
CAUTION: The cover is spring-loaded and should be removed
carefully to avoid personal injury.
3. Use a Phillips-head screwdriver to remove the Relief Valve cover
screws while holding down on the cover.
4. Lift the cover straight up.
5. Remove the Relief Valve assembly.
6. Remove the Relief Valve Spring.
7. Remove the Retainer.
8. Remove the Inlet and Outlet Check Valves.
NOTE: Clean all the parts that have been removed. Then
reassemble, or depending on their condition, discard and replace
with new replacement parts. O-rings should be cleaned or replaced
as necessary and lightly greased with NSF 61-approved grease.
B. Assembly - RP 500.
1. Securely install the Inlet and Outlet Check Valves.
2. Install the Retainer.
3. Place the Relief Valve Spring in position.
4. Install the Relief Valve assembly.
5. Put on the cover, hold it down and tighten the screws.
CAUTION:
The bolts have to be secured with a recommended torque of:
2.5 Kg/m. for models , , 1
9 Kg/m. for models 1, 1 , 2

RP-500
Trouble Shooting Guide
Symptom

Cause

1. Relief valve continuously discharges


during no-flow conditions.

2. Relief valves discharge continuously


during flow and no-flow conditions.

Corrective Action

a. Check valve #1 clogged with debris.

a. Inspect and clean the seat and seal.

b. Check valve #2 fouled with debris


accompanied by a backpressure condition.

b. Inspect and clean the seat and seal.

a. Relief valve fouled with debris.

a. Inspect and clean relief valve seat disk


and seat.

b. Damaged diaphragm (allowing water to


pass through, from inlet to zone).

b. Replace the relief valve kit.

c. Sensing passage to inlet side of diaphragm


plugged.

c. Inspect and clean passage in cover and


body.

3. Relief valve discharges intermittently


in a spitting action during no-flow
condition.

Pressure fluctuations (water hammer)


from supply.

Eliminate or reduce pressure fluctuations.

4. Relief valve does not open during field


test no.1

a. Shut-off valve #2 not closed completely.

a. Close shut-off valve #2 or inspect for


possible through leakage.

b. Test equipment improperly installed.


b. Recheck test procedure.
5. Check valve #2 fails to hold
backpressure.

a. Shut-off valve #2 not closed completely.

a. Close shut-off valve #2 or inspect for


possible through leakage.

b. Check valve #2 clogged with debris.


b. Inspect and clean the seat and seal.
6. Pressure differential across check valve
#1 is low during field test no.3 a (does not
meet 0.2 bar minimum)

a. Check valve #2 clogged with debris.

a. Inspect and clean the seat and seal.

b. Upstream pressure fluctuations causing


inaccurate gauge reading.

b. Eliminiate pressure fluctuation.

Test Cock #3
Check Valve #2

Test Cock #2

Test Cock #1
Check Valve #1
Shut-off Valve #1

Shut-off Valve #2

EnC-RP500WTR-11 139

Funnel

RP-500
A

DIMENSIONS AND WEIGHT


Nominal

Dimensions mm

Size

Weight

Kg.

1/2 3/4 1

197

167

99

0.820

1 1 2

332

229

157

2.580

* Dimensions and weight without shut-off


depends on shut-off valve model.

PARTS LIST AND SPECIFICATION


No. Part
1.

Cover Assembly

2.

Relief Valve Assembly

3.

Relief Valve Spring

4.

Retainer

5.

Inlet Check Valve Assembly

6.

Outlet Check Valve Assembly

7.

Body Assembly

8.

Test Cocks (#1, #2, #3)

9.

Adaptor Assembly

10.

Clamp Assembly

11.

Up stream Shut-Off Valve

12.

Down stream Shut-Off Valve

13.

Funnel

2
3
6
12
10

8
9

10

11

7
13

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

DC-500

Water Supply

PN 10

Backflow Preventer -Double Check Valve


Description

The DC-500 Double Check Valve is designed to provide the best


protection and durability against backflow caused by negative
pressure or backpressure. Backflow may cause infiltration of
chemicals, fertilizers and/or other pollutants into potable water
systems. The DC-500 is reliable and easily maintained without the
need for special tools.
The DC-500 has two independent, easily replaceable, spring check
valves in capsules.
The DC-500 is recommended in places where the degree of
pollution doesnt necessitate the use of an RP-500.

Operation

The Double Check Valve (DC-500) device consists of two


independently acting, spring-loaded, check valves. Two resilient
seated shut-off valves and four test cocks complete the assembly.
Each check valve is designed to maintain a minimum of 1 PSI across
the valve during normal operation. If at any time, the pressure
downstream of the device increases above the supply pressure, both
check valves will close to prevent any backflow from occurring.

Applications

- Chemical and fertilizer systems in landscape and agriculture.


- Swimming pools.
- Dairies and poultry coops.
- Food processing plants.

Main Features

EnC-DC500WTR-11 141

- Working Pressure: 10 bar.


- Sizes: 3/4, 1, 1 , 2.
- Working Temp Range: 0.5 to 450 C.
- Made of composite plastic material, resistant to corrosion, scaling,
fertilizers, herbicides, insecticides, etc.
- Internal control system ensures reliability and safety.
- Easy and quick installation.
- Economical to operate.
- Lightweight.
- UV resistant.
- Low Head-Loss.
- Meets international standards.
- Specially suited for plastic piping.
- Variety of installation options.
- Long working life with easy maintenance.

The ARI DC-500 is approved by the following Standards


authorities: ASSE 1015, AWWA, NSF 61, Water Mark (Australia),
AS2845.1., ACS (France), Approved by the Foundation for Cross
Connection Control and Hydraulic Research at the University of
Southern California (USC), Listed to Uniform Plumbing Code.

Installation

A. Install the DC-500 Double Check Valve in a location accessible


for periodic field testing and maintenance.
B. Before installing the DC-500, thoroughly flush all upstream
piping to remove debris.
C. Mount the DC-500 in a horizontal position with adequate
clearance from walls and/ or obstructions. A clearance is needed
between the lowest portion of the device and floor.
D. When the shut-off valves are supplied separately, install them
with a Test Cock on the Inlet Shutoff Valve.
E. It is recommended that a Y strainer be installed before the inlet
of the RP-500 to prevent debris from entering the device.
F. After installing the assembly, close the Outlet Shut-off Valve,
pressurize the DC-500 and release the air through Test Cock #4.
Then, open the Outlet Shut-off Valve.

Recommendations

Do not install in areas subject to extended periods of freezing


temperatures.
The product must be protected from excessive pressure increases
caused by thermal expansion or water hammer. They can damage
the valve.
DO NOT USE ANY PIPE DOPE, OIL GREASE OR
SOLVENT ON ANY PARTS unless instructed to do so.
Parts should fit together freely. Do not force parts to fit.

DC-500
Trouble Shooting Guide
Symptom

Cause

Check valve fails to hold 0.07 bar.

Corrective Action

A. Outlet shut-off valve not closed completely.

A. Close outlet shut-off valve or inspect for


possible through leakage

B. Outlet check valve fouled with debris.

B. Inspect and clean the seat and seal of


outlet check valve.

DIMENSIONS AND WEIGHT


Nominal

Dimensions mm

Size

Weight

Kg.

1/2 3/4 1

197

100

99

0.74

1 1 2

332

151

157

2.4

* Dimensions and weight without shut-off


depends on shut-off valve model.

PARTS LIST
No. Part
1.

2.
3.
4.
5.
6.
7.
8.
9.
10.
10.

Cover Assembly
Retainer
Inlet Check Valve Assembly
Body Seal
Outlet Check Valve Assembly
Test Cocks (#1, #2, #3)
Body Assembly
Adaptor Assembly
Clamp Assembly
Inlet Shut Off Valve
Outlet Shut Off Valve

1
2
3
4

5
6

11
9

8
7
8

10

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

UFR

Water Supply

PN 16

Unmeasured-Flow Reducer PATENTED


Apparent (commercial) water losses
A major cause for apparent water losses is the fact that domestic
water meters have difficulty in measuring very low flow rates
mainly below Qmin.
The minimum flow rate (Qmin), where an accuracy of +/5% is
required by the appropriate ISO standard for small domestic
water meters (Qn 1.5), is 30 l/h for class B water meters, 15 l/h
for class C water meters and 11.25 l/h for class D water meters.
Loss of income due to the under-registration of water
meters at low flow rates
Under-registration of low flow rates is the main reason for
apparent water losses and it can account for 5%-10% of the
total water sold to users by the water utility. For old water
meters, where the measuring starting point is higher and for houses
with water storage tanks, apparent water losses can be more than
10%.
Main reasons for leaks and low flow rates that cause
under-registration of the water meter:
- Dripping or improperly closed faucet.
- Leaks in toilet tank seals.
- Very low flow rates at the end of the filling cycle of toilet tanks
and water storage tanks.
- Pipework leaks downstream of the water meter.
A.R.I.s Solution: UFR - Unmeasured-Flow Reducer
UFR - Is a smart and simple product, installed in the domestic
water supply line (In-Line), adjacent to the water meter.
UFR - At low flow rates, changes the flow regime to batches
that the water meter can measure.

UFR - Operating Principles


The UFR begins working at very low flow rates, below Qmin.
The UFR regulates the water flow so there is no water flow
at all through the UFR part of the time, while the rest of the
time, the flow is high enough to be measured. A change in the
flow discipline at low flow rates allows the existing water meter
to measure those low flow rates it could not measure before.
When the flow rate increases above Qmin, the UFR remains
open, so that it does not interfere with normal measurements.
Advantages of the UFR
- Reduces unmeasured flow, cuts down apparent losses.
- Substantially increases the income of the water utility, up
to 10%.
- The UFR is a high quality check valve preventing backflow
and main pipe contamination.
- When water is billed in a block of flats according to the domestic
water meter plus the mean difference between the domestic
water meters and the main water meter, the UFR can make the
billing fairer.
- Turns apparent water losses into revenue water.
- Reduces measurement differences between the main water
meter and domestic water meters.
- Helps detect small leaks downstream of the water meter.
The A.R.I. UFR is approved by the following Standards
authorities:
WRAS, PZH, The Standards Institution of ISRAEL.

EnC-UFRWTR-11 143

UFR
How Does The UFR Work:
1. UFR closed

When pressure on both sides of the UFR is equal, the spring


pushes the plunger to the closed position.

2. UFR starts opening

Leakage causes the downstream pressure to decrease - and the


plunger moves forward, pulling the rubber seal with it.

3. UFR opens

The plunger seal disengages instantaneously and the water batch


moves quickly forward and activates the water meter.

4. UFR closes again

When pressure on both sides of the UFR is equal the spring


pushes the plunger back to the "closed" position.

UFR
MODELS - DIMENSIONS AND WEIGHTS

A
B

A
B

A
B

A
B

EnC-UFRWTR-11 145

A
B

INLET

OUTLET

A mm

B mm

WEIGHT (g)

1 BSP-U

3/4 BSPT MALE

81

47

330

3/4 BSP-U

1/2 BSPT MALE

82.5

47

290

3/4 BSP-U

3/4 BSPT MALE

85

47

310

3/4 BSP FEMALE

3/4 BSPT MALE

83.5

47

290

1/2 BSP FEMALE

1/2 BSPT MALE

80

47

270

3/4 BSP FEMALE

1/2 BSPT MALE

81

47

280

1/2 BSP FEMALE

3/4 BSPT MALE

83

47

280

1 BSP FEMALE

1 BSP FEMALE

88.5

47

350

3/4 BSPT MALE

1 BSP-U

88

47

342

1/2 BSPT MALE

1 BSP-U

85

47

300

3/4 BSPT MALE

3/4 BSP-U

85

47

310

1/2 BSPT MALE

3/4 BSP-U

82.5

47

290

3/4 BSP-U

1/2 BSP FEMALE

140

65

555

1 BSP-U

3/4 BSP FEMALE

147

73

710

1/2 BSP FEMALE

1/2 BSP FEMALE

80

64

140

3/4 BSP FEMALE

3/4 BSP FEMALE

81

64

144

1/2 BSP FEMALE

3/4 BSP FEMALE

81

64

142

3/4 BSP FEMALE

1/2 BSP FEMALE

81

64

142

1 BSP FEMALE

1 BSP FEMALE

87

64

146

UFR

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

Water Supply

Air Valve Enclosure

Description

75 cm

The A.R.I. Air Valve Enclosure is used to protect air valves in abovesurface installations.
The special enclosure hides the air valves and protects them from
vandalism and damage.

Main Features

Suitable for A.R.I. combination air valves model D-040 (3/4 , 1,


2) and D-050 (3,4 ).
Auto-locking mechanism, padlock or both.
Attaches by screws to a concrete surface.
Made of reinforced polyethylene.
Lift-off design allows full access for air valve maintenance.
Lightweight and durable.
Air vent and drainage slots.

EnC-ENCRWTR-11 147

Drainage Slots

Air Vent Slots

45 cm

Padlock

Auto-lock
Mechanism

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

SD-010 GB

Water Supply

Gear Box Driven Horizontal Sliding Disc Valve


Description

A.R.I. model SD-010GB is a 3" inlet, gear box driven horizontal


sliding disc valve designed for underground and confined space
installations. The gear box is activated by a vertical operating rod
(enables above ground operation of underground installations).
The valve provides fluid-tight sealing up to 25 bar (365 psi) working
pressure and is installed horizontally between the pipeline and the
user's device.
Integral to the valve is either a 2" or 3" threaded or quick
connection adaptor outlet. The 3" adaptor has an additional 1 "
BSP female threaded orifice perpendicular to its vertical access,
which can be used as a flushing outlet.
The quick connection adaptor has a built in safety mechanism to
prevent the accidental removal of the user's device while there is
open flow through the valve. The disc valve must be in the closed
position before the user's device can be disconnected from the quick
connection adaptor.

Applications

- Underground installations of air valves.


- Installation of air valves and valves in confined spaces.
- Fire hydrants.
- Municipal services.
- Wastewater manholes.

Operation

The valves unique design allows for operation from above, thus
enabling its use in underground and confined space applications.
An operating rod attached to the gear box from above activates the
opening and closing of the valve.
The integral 2" or 3" adaptor provides a safety mechanism that
prevents the disconnection of the adaptor and the users' device from
the horizontal disc valve when the disc valve is in the open position.

EnC-SD010GBWTR-11 149

Main Features

- Working Pressure : 16 bar, 25 bar


- Low profile enables installation in confined spaces.
- Integral 2" or 3" adaptor - quick connection and added safety
element.
- Operating rod - length upon request.

Outlet Options

Threaded Outlet Housing


2", 3" - BSP/NPT made of stainless steel.
Adaptor Housing + Adaptor w/Outlet
2" NPSM outlet, made of ductile iron.
3" BSP/NPT outlet made of ductile iron or stainless steel, with a
threaded Flushing Outlet 1" BSP.

Accessories

- T Handle Operating Rod


Made of Stainless Steel SAE 304
Length - upon request

SD-010 GB
PARTS LIST AND SPECIFICATION

DIMENSIONS AND WEIGHTS

No Part

Material

1.

Screw

Stainless Steel SAE 304

2.

Upper Body

Ductile Iron /Stainless Steel

3.

Upper Gasket

Teflon

4.

Body Gasket

E.P.D.M.

5.

Plate

Stainless Steel SAE 304

6.

Lower Body

Ductile Iron /Stainless Steel

7.

Lower Gasket

E.P.D.M. / St.St.SAE 304

8.

Operating Axis

Stainless Steel SAE 304

9.

"T" Handle

Stainless Steel SAE 304

10. Operating Rod

Dimensions mm.
A

279.4

327.66

Connection

Weight

3" NPT/BSPT Male

18

Kg.

Stainless Steel SAE 304

2" NPSM

1.5 BSP
3" BSP/NPT

GEAR BOX
PRESSURE RELIEF VALVE PLUG

PIN

3"

9
10

2"
1

2
3

C
A

4
5
6
7

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

WASTEWATER

VALVES FOR WASTEWATER APPLICATIONS

Wastewater

Installation Guide
D-020

Combination Air Valve for Wastewater

D-020 SB

Underground Air Valve System


For Wastewater

D-021

Combination Air Valve Specially Suited


for Reclaimed Water

D-023

Combination Air Valve for Wastewater

D-023 SB

Underground Air Valve System


For Wastewater

D-025

Combination Air Valve for Wastewater


Short version

D-025 SB

Underground Air Valve System


For Wastewater
EnC-INDXSWG-11 151

D-026

Combination Air Valve for Wastewate

K-020 / K-022

Air & Vacuum Valve for Wastewater

S-020 / S-022

Automatic Air Release Valve


for Wastewater

S-021

Automatic Air Release Valve


Specially Suited for Reclaimed Water

S-025

Automatic Air Release Valve


for Wastewater -Short Version

S-025 SB

Underground Air Valve System


For Wastewater

SD-010 GB

Gear Box Driven Horizontal


Sliding Disc Valve

ODOR

Odor Control Screen Assembly


For Wastewater Air Valves

NR-040

Check Valve with Removable Cover

INSTALLATION GUIDE
Thus section deals with installation recommendations for wastewater systems. Included are recommendations
for sizing the pipeline risers and the placement of air valves on the various sections of the system.
Further information can be obtained by contacting the local agent or the A.R.I. applications engineering dept.

Recommendation for Riser Dimensions


d=D
for
d=0.6 D
for
d 0.35 D for

D 300 mm
300 mm < D 1500 mm
D > 1500 mm

EnC-INSTSWG-11 153

h=D

h=D

h=D

h D and h 150 mm

INSTALLATION GUIDE
Sample Setups for Pump Stations
Air Valve Location:
An air valve shall be installed between the pump and the check valve.
The diameter and pressure of the air valve will be determined according to the design of the system.

Pump

D-020 NS
D-023

Wet Well

D-025 NS
Pump

Pump

Wet Well

D-025 NS

D-023

INSTALLATION GUIDE
Air Valve Type According to Pump Type:
A non slam type combination air valve shall be installed after a submersible or suction type pump.
An automatic air valve shall be installed after the dry well pump.
Pumping with a submersible pump.

D-020 NS

Suction pumping
(Centrifugal / Progressive Cavity pump).

D-020 NS

Dry well pumping.


EnC-INSTSWG-11 155

Wet Well
S-020

INSTALLATION GUIDE
Sample Air Valves Applications at Isolating Valves

D-025

D-023

D-025

D-023

D-025

D-025

Flo

Flo

Sample Installation Scheme


for Underground Air Valves

2"
8"

INSTALLATION GUIDE
Air Valve Location at Pump Stations and on Transmission Lines

At Peaks

D-025

D-025

D-025

On Descending Pipe Sections


every +- 500 meters

Before Descending
Pipe Sections

D-025 NS
D-025

Pump

Between the Pump


and Pump Check Valve

D-025
D-025
D-025

EnC-INSTSWG-11 157

At Increasing Pipe Slopes on


Descending Pipe Sections

INSTALLATION GUIDE

At the Ends of Overhead Crossings

D-025

At the Ends of Underground Road Crossings

D-025

D-025

Air Discharge at Dead Ends

D-025

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-020

Wastewater

PN 16

Combination Air Valve for Wastewater


Description

The D-020 Combination Air Valve combines an air & vacuum


orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as wastewater and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

-Pump stations for sewage, wastewater & water treatment plants.


-Wastewater, effluent water and sea water supply lines.

Operation

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.

EnC-D020SWG-11 159

Without air valves, pockets of accumulated air may cause the


following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.

As the system starts to fill, the combination wastewater valve


functions according to the following stages:
1. Entrapped air/gas is discharged by the valve
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.2 - 16 bar.


- Testing pressure: 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Spring-loaded joint between the stem and the upper float:
vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
The Rolling Seal Mechanism: less sensitive to pressure
differentials than a direct float seal. It accomplishes this by having a

D-020
comparably large orifice for a wide pressure range (up to 16 bar).
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- All inner metal parts made of stainless steel.
- 1" threaded discharge outlet enables removal of excess fluids.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- 1" ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- Size range 2" 8".


- These valves are manufactured with flanged ends to meet any
requested standard
- The 2 valve is also available with a threaded BSP or NPT
connection.
- Standard metal body, also available with a stainless steel body.
- Valve body coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- Additional accessories:
With a One-way, Out-only attachment, allows for air discharge
only, prevents air intake.
With a Vacuum Breaker, In-only attachment, allows for air intake
only, prevents air discharge.
With a Non-Slam discharge-throttling attachment, allows for free
air intake, throttles air discharge.

Note

- The D-020 air valve is intended for use with raw wastewater. For
use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-020 Non-Slam Single Orifice Add-on Component Data Table


Nominal
Size

Discharge
orifice

Total NS
area

NS orifice

2 (50mm)
3" (80mm)

37.5 mm

12.6 mm2

4 mm

Switching
point

Flow at
0.4 bar

Spring loaded
normally closed

17.5 m3/h

D-020-NS

D-020

DIMENSIONS AND WEIGHTS


Nominal

Dimensions mm

Size

Connection

Weight Kg.

Orifice Area mm2

Steel

ST ST

Auto.

A/V

2 (50mm) Threaded

550

644

1 BSP Female

16.5

15.8

12

804

2 (50mm) Flanged

550

605

1 BSP Female

17.5

17.0

12

804

3 (80mm)

550

605

1 BSP Female

18.5

18.5

12

804

4 (100mm)

550

605

1 BSP Female

19.5

19.5

12

804

6 (150mm)

550

610

1 BSP Female

21.0

21.0

12

804

8 (200mm)

550

610

1 BSP Female

24.0

22.0

12

804

PARTS LIST AND SPECIFICATION


1

No Part

Material

1.

Discharge Outlet

Polypropylene

2.

Rolling Seal Assembly

Nylon + E.P.D.M. + ST ST

3.

Float

Foamed Polypropylene

4.

Clamping Stem

Reinforced Nylon

5.

Body

Reinforced Nylon / ST ST SAE 316

6.

Cover

Reinforced Nylon / ST ST SAE 316

4
5
6

7. O-Ring

BUNA-N

8. O-Ring

BUNA-N

9.

EnC-D020SWG-11 161

Stainless Steel SAE 304

10. Stopper

Domed Nut

Polypropylene

11. Spring

Stainless Steel SAE 316

10

12. Washer

Stainless Steel SAE 316

13. Bolt & Nut

Stainless Steel SAE 316

14. Stem

Stainless Steel SAE 316

11
12

15. Float

Polycarbonate / ST ST SAE 316

13

16. Ball Valve 1

Brass ASTM A124 Chrome Coated

/ ST ST SAE 316

14

17. Body

4" - 8"

Steel DIN St.37 / ST ST SAE 316

2", 3"

Steel DIN St.37 / ST ST SAE 316

/ Steel ASTM A216 WCB

/ ST ST ASTM A744 CF8M

15
16
17

D-020-SB

Wastewater

PN 16

Underground Air Valve System for Wastewater


Description

The D-020 SB is a complete product package that combines the


reliable and efficient properties of the A.R.I. D-020 combination
wastewater air valve with the added feature of a sub-surface valve
that can be buried below ground. A specially designed gear box
operated horizontal sliding disc valve - situated at the base of the
D-020 SB assembly - allows for the air valve disconnection and
maintenance from ground level.
This shut-off valve is equipped with a safety mechanism enabling
disconnection and removal of the D-020 air valve from its
subsurface housing, even when the system is under pressure. Since
service and maintenance operations of the unit are performed
entirely from the surface, there is no need for safety considerations
associated with confined space entry.
The D-020 Combination Air Valve combines an air & vacuum
orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as wastewater and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

- Pump stations for sewage, wastewater & water treatment plants.


- Wastewater, effluent water and sea water supply lines.

Operation

EnC-D020SBSWG-11 163

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.

Without air valves, pockets of accumulated and entrained air


may cause the following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of high-energy bursts of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the combination wastewater valve
functions according to the following stages:
1. Entrapped air/gas is discharged by the valve.
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal.
The air release orifice opens and allows part of the air that
accumulated in the upper portion of the valve to be released to the
atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

D-020-SB
Main Features

D-020 SB Underground Air Valve System for


Wastewater:

- The D-020 SB incorporates an integral, flat, gear box operated


horizontal sliding disc valve with a 3 full bore passage.
- The shut-off valve is operated from the surface.
- Easy and efficient back flushing can be achieved while the air valve
is in its sub-surface housing.
- All connections utilize quick connectors to facilitate easy usage
during:
1. Handling (quick connector from adaptor to shut-off valve)
2. Maintenance operations (quick connectors on both the inlet &
outlet flushing positions).
-Safety elements: Disengaging the air valve is safeguarded: unless the
shut-off valve is in the closed position and the internal pressure is
released, it is not possible to extract the air valve.
- Pipe connections: 3 threaded (BSP/NPT) or flanged, in
accordance with all standards.
- All parts are corrosion resistant: Metal parts made of Stainless
Steel, Ductile Iron or steel, Composite material parts made of
Nylon, PA, and PVC
- Drainage system: a special one-way valve that drains the water
from the valve box and does not admit water.

Advantages and Benefits


- Relatively lightweight and convenient to install.
- Sub-surface installation.
- Low installation costs:
1. No need for expensive, large excavation.
2. No need for expensive, human-accessible manholes.
- Low Maintenance costs:
1. No need for specialized tools or safety equipment.
2. One person for operation and maintenance.
3. Clean and environmentally friendly.
4. Complete service and maintenance system, including an integral
disassembly mechanism to ensure easy back flushing and servicing,
while reducing the need for spare changeable valves.
- Safe in operation:
1. Greatly reduces the danger of contact with local fauna snakes
and scorpions, etc!
2. Entirely operated and maintained from ground level.
- Reliable and efficient operation:
1. Dynamic design allows high velocity air discharge while
preventing premature closure.
2. A.R.I. patented Rolling Seal mechanism.
3. Since the valve is a sub-surface (underground), it is more resistant
to frost conditions.

Valve Selection

- Working pressure range: 0.2 - 16 bar.

- Two different installation lengths:


1. 800mm tube; complete system length: 934 mm.
2. 1000mm tube; complete system length: 1134 mm.

- Testing pressure: 25 bar.

- Air valve body: Stainless Steel SAE 316 or Steel DIN St.37.

- Maximum working temperature: 60 C.

- Valve body coating: fusion bonded epoxy coating according to the


standard DIN 30677-2.

D-020 Combination Wastewater Air Valve:

- Maximum intermittent temperature: 90 C.


- A combination air valve for wastewater, with a large air & vacuum
orifice and a small air release orifice integrated into one body.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
1. The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
2. Spring-loaded joint between the stem and the upper
float: vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
3. The Rolling Seal Mechanism: less sensitive to pressure
differentials than a direct float seal. It accomplishes this by having a
comparably large orifice for a wide pressure range (up to 16 bar).
4. Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- All inner metal parts made of stainless steel.

- Other coatings are available upon request.


- Cover and top air valve body: Reinforced Nylon or Stainless Steel
SAE 316.
- Additional Accessories:
1. With a One-way, Out-only attachment, allows for air discharge
only, prevents air intake.
2. With a Vacuum Breaker, In-only attachment, allows for air
intake only, prevents air discharge.
3. With a Non-Slam discharge-throttling attachment, allows for free
air intake, throttles air discharge.

Note

- The D-020 air valve is intended for use with raw wastewater. For
use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-020-SB
UNDERGROUND AIR VALVE SYSTEM
PARTS LIST AND SPECIFICATION
No Part

Material

1.

Discharge Outlet

Polypropylene

2.

Valve Box Cover

Polyethylene

3.

Lifting Handle

Stainless Steel SAE 304

4.

Ball Valve 1 1/2

Stainless Steel SAE 304

5.

Pressure Relief Valve

Stainless Steel SAE 316

6.

Back Flushing Assembly

Polyethylene

7.

Operating Rod

Stainless Steel SAE 304

8.

D-020 Air Valve

see below

9.

Sliding Disc Valve w/ Gear Box

DI+STST+E.P.D.M.

/STST+STST+E.P.D.M.

10. Adaptor - Quick Connector 3

Stainless Steel SAE 316

11. Safety Handle

Stainless Steel SAE 316

12. T Key

Stainless Steel SAE 304

13. Valve Box

Polyethylene

14. Flange 3

Reinforced Nylon

/Stainless Steel SAE 316

1
2
3
4
5
6
7

8
9
10
11
12
13
14

D-020 PARTS LIST AND SPECIFICATION

EnC-D020SBSWG-11 165

No. Part

Material

1. Discharge Outlet

Polypropylene

2. Rolling Seal Assembly

Reinforced Nylon+E.P.D.M+St.St.

3. Float

Foamed Polypropylene

4. Clamping Stem

Reinforced Nylon

5. Body

Reinforced Nylon /Stainless Steel SAE 316

6. Bolt, Nut & Washer

Stainless Steel SAE 316

7. Cover

Reinforced Nylon /Stainless Steel SAE 316

8. O-Ring

BUNA-N

9. Domed Nut

Stainless Steel SAE 304

10. Stopper

Polypropylene

11. O-Ring

BUNA-N

10

12. Spring

Stainless Steel SAE 316

13. Washer

Stainless Steel SAE 316

14. Stem

Stainless Steel SAE 316

13

15. Float

Polycarbonate /Stainless Steel SAE 316

14

16. Plug

Stainless Steel SAE 304

17. Body

Steel DIN St. 37 / Stainless Steel SAE 316

15

6
7

11
12

16
17

D-020-SB
Sample Installation Scheme

Important Information: Prior to site preparation and installation,


please refer to the D-020 SB Installation and Maintenance Manual
for all the relevant instructions and information. The manual can be
obtained by contacting the A.R.I marketing dept., from your local
A.R.I. distributor or downloading the file from our website.

DIMENSIONS AND WEIGHTS

Model

A

Dimensions
B
C
D

Weight
Kg.

Orifice Area mm2


Auto. A / V

L800 448 934 875 806 46.8

12 804

L1000 448 1134 1075 1006 49.8

12

804

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-021

Reclaimed Water

PN 10

Combination Air Valve - Reclaimed and Non-Potable Water


Description

The D-021 Combination Air Valve combines an air & vacuum


orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as reclaimed water and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

- Reclaimed water
- Raw water
- Effluent water
- Water with suspended solids
- Coolant water

Operation

EnC-D021SWG-11 167

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The automatic air release component releases entrapped air in
pressurized systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
-Danger of high-energy bursts of compressed air.

- Inaccuracies in flow metering.


As the system starts to fill, the combination wastewater valve
functions according to the following stages:
1. Entrapped air/gas is discharged by the valve.
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter into the system.

Main Features

- Working pressure range: 0.2 - 10 bar


Testing pressure: 16 bar
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Spring-loaded joint between the stem and the upper float:
vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
The Rolling Seal Mechanism: less sensitive to pressure
differentials than a direct float seal. It accomplishes this by having a

D-021
comparably large orifice for a wide pressure range (up to 10 bar).
Funnel-shaped lower body: designed to ensure that residue
reclaimed water solid matter will fall back into the system and be
carried away by the main pipe.
- Body made of composite materials, resistant to corrosion.
- Internal metal parts are made of corrosion-resistant stainless steel.
Floats are made of composite materials.
- Flexible rolling seal provides smooth positive opening, closing, and
leak-free sealing over a wide range of pressure differentials.
- Drainage tap with ball valve is provided.
- 3/8 threaded discharge outlet enables removal of excess fluids.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- 1/4 ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- Size Range: 1& 2 with a BSP/NPT male threaded connection or


with flanged ends to meet any requested standard.
- Additional one-way out check valve attachment allows air
discharge, not allowing air intake.

Note

- The D-021 air valve is intended for use with raw wastewater. For
use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

DIMENSIONS AND WEIGHTS


Dimensions mm
A

216

324

Connection

Weight

3/8 BSP Female

1.78

Kg.

Orifice Area mm2


Auto.

A/V

7.8

100

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M.

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Body

Reinforced Nylon

8. Float Stem

Stainless Steel SAE 316

9. Clamp

Reinforced Nylon

+ Stainless Steel SAE 316

10. O-Ring

BUNA-N

11. Float

Foamed Polypropylene

12. Base

Reinforced Nylon

13. Ball Valve 1/4

Brass Nickel Plated

1
2
3
4
5
6
7
8
9
10
11
12
13

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-023

Wastewater

PN 16

Combination Air Valve for Wastewater


Description

The D-023 Combination Air Valve combines an air & vacuum


orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as wastewater and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

- Pump stations for sewage, waste water & water treatment plants.
- Wastewater, effluent water and sea water supply lines.

Operation

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The automatic air release component releases entrapped air in
pressurized systems.

EnC-D023SWG-11 169

Without air valves, pockets of accumulated and entrained air


may cause the following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of high-energy bursts of compressed air.
- Inaccuracies in flow metering.

PATENTED

As the system starts to fill, the combination wastewater valve


functions according to the following stages:
1.Entrapped air/gas is discharged by the valve
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure (negative
pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.2 - 16 bar.


- Testing pressure: 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape and the external lever: designed to
maintain the maximum distance between the liquid and the sealing
mechanism and still obtain minimum body length.
Spring loaded joint between the stem and the upper float:
vibrations of the lower float will not unseal the automatic valve.
Release of air will occur only after enough air accumulates.
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- All inner metal parts made of Stainless Steel.

D-023
- Unique design of external lever prevents contact between the
wastewater and the sealing mechanism, prevents clogging by floating
solids and ensures drip-tight sealing.
- The D-023s orifice plug-disc linkage assembly is external, keeping
the levers and pins outside the air valve body and its corrosive
atmosphere.
- 1 ball valve releases trapped pressure and drains the valve body
prior to maintenance.
- Discharge outlet enables removal of excess fluids

- Additional coatings available upon request.


- Optional Accessories
With a One-way, Out-only attachment, allows for air discharge
only, prevents air intake.
With a Vacuum Breaker, In-only attachment, allows for air intake
only, prevents air discharge.
With a Non-Slam discharge-throttling attachment, allows for free
air intake, throttles air discharge - Model D-023 NS.

Valve Selection

- The D-023 air valve is intended for use with raw wastewater. For
use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

- Size range availability: 3 - 8.


- Valves manufactured with flange ends to meet any requested
standard.
- Standard metal body, also available with a ST ST body.
- Valve body coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.

Note

DIMENSIONS AND WEIGHTS


Nominal
Size

Dimensions mm

Connection

Weight

Kg.

Orifice Area mm2

Auto.

A/V

3 (80 mm)

554

580

3" BSP / NPSM Female

22

15.7

5024

4 (100 mm)

554

580

3 BSP / NPSM Female

23

15.7

5024

6 (150 mm)

554

580

3 BSP / NPSM Female

24.5

15.7

5024

8 (200 mm)

554

580

3 BSP / NPSM Female

27.5

15.7

5024

D-023
PARTS LIST AND SPECIFICATION
No. Part

Material

1.

Ductile Iron ASTM A-536-60-40-18

Cover

/ ST ST ASTM A744 CF8M

2.

Disk Arm Assy.

ST ST SAE 316 + E.P.D.M.

3.

Orifice (Ductile Body only) Bronze B 62

4. O-Ring

BUNA-N

5.

Rivet

ST ST SAE 304

6.

Air & Vacuum Disc

Reinforced Nylon / ST ST ASTM A744 CF8M

7.

Air & Vacuum Disc Seal

E.P.D.M.

19

8.

Air Release Disc Seal

E.P.D.M.

20

9.

Bolt (Screw)

ST ST SAE 304

21

10. Air Release Disc

Reinforced Nylon

22

11. Air Release Disc Cover

Reinforced Nylon

12. Pin

ST ST SAE 304

13. Rod Adaptor

Polypropylene

14. Domed Nut

ST ST SAE 304

15. Stopper

Polypropylene

16. Spring

ST ST SAE 316

17. Float Assy.

Polycarbonate + ST ST 316 / ST ST

18. Body

Steel Din St.37 / ST ST SAE 316

23
24
25

/ Steel A216 WCB / ST ST ASTM A744 CF8M


4 - 8

Steel Din St.37 / ST ST SAE 316

19. Bolt

ST ST SAE 304

20. Washer

ST ST SAE 304

21. Bolt, Nut & Washer

ST ST SAE 316

22. Ball Valve 1

Brass, Chrome Coated / ST ST

23. Plug

Polypropylene

24. Bushing

Acetal

25. Domed Nut

ST ST SAE 316

1
2
3
4
5
6
7
8
9
10
11
12
13
14

EnC-D023SWG-11 171

15

16
17
18

D-023
Two-directional discharge outlet cover
The D-023 combination air valve for wastewater is available with an
optional stainless steel two-directional discharge outlet cover.
One outlet is always open for air discharge while the other is closed
with a plug. Both outlets have a 3 female thread.
With this option, air can be discharged either in a horizontal or
vertical direction, depending on the installation. This option allows
for easy vertical air discharge from valves installed in manholes.
This cover is standard on all D-023 SB underground air valves and
is optional for all D-023 air valves, both stainless steel and epoxy
coated.

DIMENSIONS AND WEIGHTS


Nominal
Size

Dimensions mm

Connection

Weight

Auto.

A/V

25

15.7

5024

Kg.

Orifice Area mm2

3 (80 mm)

500

620

3" BSP / NPSM Female

4 (100 mm)

500

620

3 BSP / NPSM Female

26

15.7

5024

6 (150 mm)

500

620

3 BSP / NPSM Female

27.5

15.7

5024

8 (200 mm)

500

620

3 BSP / NPSM Female

30.5

15.7

5024

D-023 NS
Combination Air Valve for Wastewater - Non Slam
The D-023 Combination Wastewater Non Slam accessory will
dampen surge and prevent slam. The non slam accessory provides
efficient surge suppression.
At sudden drainage and/or water column separation (sudden pump
trips or valve closure, for instance), the air & vacuum orifice admits
air at high flow rates, thus preventing vacuum. As the water column
and/or pressure wave returns, the large volumes of air are exhausted
slowly through the smaller orifice of the non-slam acessory. This
slowly exhausting air pocket dampens the slam of the returning
water column, thus suppressing the pressure surge. As the water flow
arrives at a much slower rate, dampened by the slower air discharge,
it buoys up the main float, gently closing the air & vacuum
component of the air valve.

DIMENSIONS AND WEIGHTS


Nominal

Dimensions mm

Size

Connection

Weight

Orifice Area mm2

EnC-D023SWG-11 173

Kg.

Auto.

A/V

3 (80 mm)

573

580

3" BSP / NPSM Female

22.45

15.7

5024

4 (100 mm)

573

580

3 BSP / NPSM Female

23.45

15.7

5024

6 (150 mm)

573

580

3 BSP / NPSM Female

24.95

15.7

5024

8 (200 mm)

573

580

3 BSP / NPSM Female

27.95

15.7

5024

D-023 NS Non-Slam Add-on Component Data Table for Variable Orifices


Model

Discharge
orifice mm

Total NS
area mm2

NS orifice
mm

1 orifice

75

50.3

2 orifice

75

100.5

11.3

3 orifice

75

150.8

13.9

Switching
point
Spring loaded
normally closed

Flow at
0.4 bar
m3/h
17.5
75
105

D-023-SB

Wastewater

PN 16

Underground Air Valve System for Wastewater


Description

The D-023 SB is a complete product package that combines the


reliable and efficient properties of the A.R.I. D-023 combination
wastewater air valve with the added feature of a sub-surface valve
that can be buried below ground. A specially designed gear box
operated horizontal sliding disc valve - situated at the base of the
D-023 SB assembly - allows for the air valve disconnection and
maintenance from ground level.
This shut-off valve is equipped with a safety mechanism enabling
disconnection and removal of the D-023 air valve from its
subsurface housing, even when the system is under pressure. Since
service and maintenance operations of the unit are performed
entirely from the surface, there is no need for safety considerations
associated with confined space entry.
The D-023 Combination Air Valve combines an air & vacuum
orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as wastewater and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

- Pump stations for sewage, wastewater & water treatment plants.


- Wastewater, effluent water and sea water supply lines.

Operation

EnC-D023SBSWG-11 175

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.

Without air valves, pockets of accumulated and entrained air


may cause the following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of high-energy bursts of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the combination wastewater valve
functions according to the following stages:
1. Entrapped air/gas is discharged by the valve.
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal.
The air release orifice opens and allows part of the air that
accumulated in the upper portion of the valve to be released to the
atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

D-023-SB
Main Features
D-023SB Underground Air Valve System for
Wastewater:

- The D-023 SB incorporates an integral, flat, gear box operated


horizontal sliding disc valve with a 3 full bore passage.
- The shut-off valve is operated from the surface.
- Easy and efficient back flushing can be achieved while the air valve
is in its sub-surface housing.
- All connections utilize quick connectors to facilitate easy usage
during:
1. Handling (quick connector from adaptor to shut-off valve)
2. Maintenance operations (quick connectors on both the inlet &
outlet flushing positions).
-Safety elements: Disengaging the air valve is safeguarded: unless the
shut-off valve is in the closed position and the internal pressure is
released, it is not possible to extract the air valve.
- Pipe connections: 3 threaded (BSP/NPT) or flanged, in
accordance with all standards.
- All parts are corrosion resistant: Metal parts made of Stainless
Steel, Ductile Iron or steel, Composite material parts made of
Nylon, PA, and PVC
- Drainage system: a special one-way valve that drains the water
from the valve box and does not admit water.
D-023 Combination Wastewater Air Valve PATENTED
- Working pressure range: 0.2 - 16 bar.
- Testing pressure: 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- A combination air valve for wastewater, with a large air & vacuum
orifice and a small air release orifice integrated into one body.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
1. The conical body shape and the external lever: designed to
maintain the maximum distance between the liquid and the sealing
mechanism and still obtain minimum body length.
2. Spring-loaded joint between the stem and the upper
float: vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
3. Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- All inner metal parts made of stainless steel.
- Unique design of external lever prevents contact between the
wastewater and the sealing mechanism, prevents clogging by floating
solids and ensures drip-tight sealing.
- The D-023s orifice plug-disc linkage assembly is external, keeping
the levers and pins outside the air valve body and its corrosive
atmosphere.

Advantages and Benefits


- Relatively lightweight and convenient to install.
- Sub-surface installation.
- Low installation costs:
1. No need for expensive, large excavation.
2. No need for expensive, human-accessible manholes.
- Low maintenance costs:
1. No need for specialized tools or safety equipment.
2. One person for operation and maintenance.
3. Clean and environmentally friendly.
4. Complete service and maintenance system, including an integral
disassembly mechanism to ensure easy back flushing and servicing,
while reducing the need for spare changeable valves.
- Safe in operation:
1. Greatly reduces the danger of contact with local fauna snakes
and scorpions, etc!
2. Entirely operated and maintained from ground level.
- Reliable and efficient operation:
1. Dynamic design allows high velocity air discharge while
preventing premature closure.
2. Since the valve is a sub-surface (underground), it is more resistant
to frost conditions.

Valve Selection

- Two different installation lengths:


1. 800 mm tube; complete system length: 1010 mm.
2. 1000 mm tube; complete system length: 1210 mm.
- Air valve body and cover: Stainless Steel SAE 316 or Steel DIN
St.37.
- Valve body coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.

Note

- The D-023 SB air valve is intended for use with raw wastewater.
For use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-023-SB
UNDERGROUND AIR VALVE SYSTEM
PARTS LIST AND SPECIFICATION

No Part

Material

1.

Discharge Outlet

Polypropylene

2.

Valve Box Cover

Polyethylene

3.

Lifting Handle

Stainless Steel SAE 304

4.

Ball Valve 1 1/2

Stainless Steel SAE 304

5.

Pressure Relief Valve

Stainless Steel SAE 316

6.

Back Flushing Assembly

Polyethylene

7.

Operating Rod

Stainless Steel SAE 304

8.

D-023 Air Valve

see below

9.

Sliding Disc Valve w/ Gear Box

DI+STST+E.P.D.M.

2
3
4
5

/STST+STST+E.P.D.M.

10. Adaptor - Quick Connector 3

Stainless Steel SAE 316

11. Safety Handle

Stainless Steel SAE 316

10

12. T Key

Stainless Steel SAE 304

13. Valve Box

Polyethylene

11

14. Flange 3

Reinforced Nylon

/Stainless Steel SAE 316

12
13
14

D-023 PARTS LIST AND SPECIFICATION


No. Part

Material

1.

Cover

Stainless Steel

2.

Disk Arm Assembly

Stainless Steel SAE 316 +Rubber

3.

Air & Vacuum Disc

ST ST SAE 316 / Reinforced Nylon

4.

Air & Vacuum Disc Seal

5.

11

12

E.P.D.M.

13

Air Release Disc Seal

E.P.D.M.

6.

Air Release Disc

Reinforced Nylon

14

7.

Pin

Stainless Steel SAE 316

15

8. Stopper

Polypropylene

16

9.

ST ST316 / Polycarbonate+St.St.316

17

10. Plug

Stainless Steel SAE 304

11.

PVC

18

Float Assy.
Plug

EnC-D023SBSWG-11 177

12. Rivet

Stainless Steel SAE 304

13 . O-Ring

BUNA-N

14. Bolt

Stainless Steel SAE 316

15. Air Release Disc Cover

Reinforced Nylon

16. Domed Nut

Stainless Steel SAE 304

17. Rod Adaptor

Polypropylene

18. Spring

Stainless Steel SAE 316

19. Body

Stainless Steel / Steel Din St.37

19

8
9
10

D-023-SB
Sample Installation Scheme

Important Information: Prior to site preparation and installation,


please refer to the D-023 SB Installation and Maintenance Manual
for all the relevant instructions and information. The manual can be
obtained by contacting the A.R.I marketing dept., from your local
A.R.I. distributor or downloading the file from our website.

DIMENSIONS AND WEIGHTS

Model

A

Dimensions
B
C
D
1010

875

806

Weight
Kg.

L800

448

53.5

L1000

448 1210 1075 1006 57.3

Orifice Area mm2


A / V
Auto.
5024

15.7

5024

15.7

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-025

Wastewater

PN 10

Combination Air Valve for Wastewater - Short Version


Description

The D-025 Combination Air Valve combines an air & vacuum


orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as wastewater and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

- Pump stations for sewage, wastewater & water treatment plants.


- Wastewater, effluent water and sea water supply lines.

Operation

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the systems.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.

EnC-D025SWG-11 179

Without air valves, pockets of accumulated air may cause the


following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of high-energy bursts of compressed air.
- Inaccuracies in flow metering.

As the system starts to fill, the combination wastewater valve


functions according to the following stages:
1. Entrapped air/gas is discharged by the valve
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter into the system.

Main Features

- Working pressure range: 0.2 - 10 bar.


- Testing pressure: 16 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Spring-loaded joint between the stem and the upper float:
vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
The Rolling Seal Mechanism: less sensitive to pressure
differentials than a direct float seal. It accomplishes this by having a

D-025
comparably large orifice for a wide pressure range (up to 16 bar).
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- All inner metal parts made of stainless steel. Float made of
composite materials.
- 1 threaded discharge outlet enables removal of excess fluids.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- 1/4 ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- These valves are available in 2, 3, and 4 with a BSP/NPT male


threaded connection or flanged, standard upon request.
- Valve is manufactured of composite materials, also available in
stainless steel SAE 316 or ductile iron.
- With a One-way, Out-only attachment, allows for air discharge
only, prevents air intake.
- With a Vacuum Breaker, In-only attachment, allows for air intake
only, prevents air discharge.
- With a Non-Slam discharge-throttling attachment, allows for free
air intake, throttles air discharge.

Note

- The D-025 air valve is intended for use with raw wastewater. For
use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-025-NS
D-020 Non-Slam Single Orifice Add-on Component Data Table
Nominal
Size
2 (50mm)
3" (80mm)
4 (100mm)

Discharge
orifice

Total NS
area

NS orifice

37.5 mm

12.6 mm2

4 mm

Switching
point

Flow at
0.4 bar

Spring loaded
normally closed

17.5 m3/h

D-025
DIMENSIONS AND WEIGHTS
Nominal

Dimensions mm

Size

2 (50mm) Threaded

370

2 (50mm) Flanged
3 (80mm) Threaded

Connection
C

RN

455

1 BSP Female

370

460

370

455

3 (80mm) Flanged

370

4 (100mm) Threaded

370

4 (100mm) Flanged

370

Weight Kg.
ST ST

DI

3.8

14.4

1 BSP Female

4.2

1 BSP Female

3.8

460

1 BSP Female

455

1 BSP Female

460

1 BSP Female

Orifice Area mm2


Auto.

A/V

14.4

12

804

16.2

16.2

12

804

14.7

14.7

12

804

5.4

16.5

16.5

12

804

3.9

16.6

16.6

12

804

6.0

18.4

18.4

12

804

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Discharge Outlet

Polypropylene

2. Rolling Seal Assembly

RN + E.P.D.M. + ST ST

3. Float

Foamed Polypropylene

4. Clamping Stem

Reinforced Nylon

5. Body

Reinforced Nylon

/ Stainless Steel SAE 316

A
2

6. Domed Nut

Stainless Steel SAE 316

7. O-Ring

BUNA-N

8. Stopper

Polypropylene

9. Spring

Stainless Steel SAE 316

10. Washer

Stainless Steel SAE 316

11. Stem

Stainless Steel SAE 316

12. Body

Reinforced Nylon

/ Ductile Iron

/ Stainless Steel SAE 316

13. Clamp

Reinforced Nylon

+ Stainless Steel SAE 316

10

Stainless Steel SAE 316

11

RN Body

ST ST/ DI Body

EnC-D025SWG-11 181

14. O-Ring

BUNA-N

15. Float

Foamed Polypropylene

16. Tap 1/4

Brass ASTN A124 / Stainless Steel

17. Washer

Stainless Steel SAE 316

18. Base

Reinforced Nylon

/ Ductile Iron

/ Stainless Steel SAE 316

19. Flange

Reinforced Nylon

/ Ductile Iron

/ Stainless Steel SAE 316

* in STST or DI Body, the flange is an integral part of the base.

3
4
5
6
7

12
13
16

14
15

19

17
18

D-025-SB

Wastewater

PN 10

Underground Air Valve System for Wastewater


Description

The D-025 SB is a complete product package that combines the


reliable and efficient properties of the A.R.I. D-025 combination
wastewater air valve with the added feature of a sub-surface valve
that can be buried below ground. A specially designed gear box
operated horizontal sliding disc valve - situated at the base of the
D-025 SB assembly - allows for the air valve disconnection and
maintenance from ground level.
This shut-off valve is equipped with a safety mechanism enabling
disconnection and removal of the D-025 air valve from its
subsurface housing, even when the system is under pressure. Since
service and maintenance operations of the unit are performed
entirely from the surface, there is no need for safety considerations
associated with confined space entry.
The D-025 Combination Air Valve combines an air & vacuum
orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as wastewater and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

- Underground municipal and industrial wastewater and effluent


pressurized pipelines.
- Underground pressurized pipelines conveying liquids with
suspended solids and grime.

Operation
EnC-D025SBSWG-11 183

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized

systems.
Without air valves, pockets of accumulated and entrained air
may cause the following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of high-energy bursts of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the combination wastewater valve
functions according to the following stages:
1. Entrapped air/gas is discharged by the valve.
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal.
The air release orifice opens and allows part of the air that
accumulated in the upper portion of the valve to be released to the
atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air will enter the system.

D-025-SB
Main Features
D-025 SB Underground Air Valve System for
Wastewater:

- The D-025 SB incorporates an integral, flat, gear box operated


horizontal sliding disc valve with a 3 full bore passage.
- The shut-off valve is operated from the surface.
- Easy and efficient back flushing can be achieved while the air valve
is in its sub-surface housing.
- All connections utilize quick connectors to facilitate easy usage
during:
1. Handling (quick connector from adaptor to shut-off valve)
2. Maintenance operations (quick connectors on both the inlet &
outlet flushing positions).
-Safety elements: Disengaging the air valve is safeguarded: unless the
shut-off valve is in the closed position and the internal pressure is
released, it is not possible to extract the air valve.

Advantages and Benefits


- Relatively lightweight and convenient to install.
- Sub-surface installation.
- Low installation costs:
1. No need for expensive, large excavation.
2. No need for expensive, human-accessible manholes.
- Low Maintenance costs:
1. No need for specialized tools or safety equipment.
2. One person for operation and maintenance.
3. Clean and environmentally friendly.
4. Complete service and maintenance system, including an integral
disassembly mechanism to ensure easy back flushing and servicing,
while reducing the need for spare changeable valves.
- Safe in operation:
1. Greatly reduces the danger of contact with local fauna snakes
and scorpions, etc!
2. Entirely operated and maintained from ground level.

- All parts are corrosion resistant: Metal parts made of Stainless


Steel, Ductile Iron or steel, Composite material parts made of
Nylon, PA, and PVC

- Reliable and efficient operation:


1. Dynamic design allows high velocity air discharge while
preventing premature closure.
2. A.R.I. patented Rolling Seal mechanism.
3. Since the valve is a sub-surface (underground), it is more resistant
to frost conditions.

- Drainage system: a special one-way valve that drains the water


from the valve box and does not admit water.

Valve Selection

- Pipe connections: 3 threaded (BSP/NPT) or flanged, in


accordance with all standards.

D-025 Combination Wastewater Air Valve:

- Two different installation lengths:


1. 800mm tube; complete system length: 970 mm.
2. 1000mm tube; complete system length: 1170 mm.

- Working pressure range: 0.2 - 10 bar.

- Air valve body: Composite Materials or Stainless Steel SAE 316.

- Testing pressure: 16 bar.

- Cover and top air valve body: Reinforced Nylon or Stainless Steel
SAE 316.

- Maximum working temperature: 60 C.


- Maximum intermittent temperature: 90 C.
- A combination air valve for wastewater, with a large air & vacuum
orifice and a small air release orifice integrated into one body.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
1. The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
2. Spring-loaded joint between the stem and the upper
float: vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
3. The Rolling Seal mechanism: less sensitive to pressure
differentials than a direct float seal. It accomplishes this by having a
comparably large orifice for a wide pressure range (up to 10 bar).
4. Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- All inner metal parts made of stainless steel. Float made of
composite materials.

- Additional Accessories:
1. With a One-way, Out-only attachment, allows for air discharge
only, prevents air intake.
2. With a Vacuum Breaker, In-only attachment, allows for air
intake only, prevents air discharge.
3. With a Non-Slam discharge-throttling attachment, allows for free
air intake, throttles air discharge.

Note

- The D-025 SB air valve is intended for use with raw wastewater.
For use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-025-SB
UNDERGROUND AIR VALVE SYSTEM
PARTS LIST AND SPECIFICATION
No. Part

Material

1.

Discharge Outlet

Polypropylene

2.

Valve Box Cover

Polyethylene

3.

Ball Valve 1 1/2

Stainless Steel SAE 304

4.

Pressure Relief Valve

Stainless Steel SAE 316

5.

Lifting Handle

Stainless Steel SAE 304

6.

Back Flushing Assembly

Polyethylene

7.

Operating Rod

Stainless Steel SAE 304

8.

D-025 Air Valve

see below

9.

Sliding Disc Valve w/ Gear Box

DI+STST+E.P.D.M.

1
2
3
4

7
8

/STST+STST+E.P.D.M.

10. Adaptor - Quick Connector 3

Stainless Steel SAE 316

11. Safety Handle

Stainless Steel SAE 316

12. T Key

Stainless Steel SAE 304

10
11

13. Valve Box

Polyethylene

14. Flange 3

Reinforced Nylon

/Stainless Steel SAE 316

12
13
14

EnC-D025SBSWG-11 185

D-025 PARTS LIST AND SPECIFICATION

No. Part

Material

1. Discharge Outlet

Polypropylene

2. Rolling Seal Assembly

Reinforced Nylon + E.P.D.M + ST ST

3. Float

Foamed Polypropylene

4. Clamping Stem

Reinforced Nylon

5. Body

Reinforced Nylon

6. Domed Nut

Stainless Steel SAE 316

7. O-Ring

BUNA-N

8. Stopper

Polypropylene

9. Spring

Stainless Steel SAE 316

10. Washer

Stainless Steel SAE 316

11. Stem

Stainless Steel SAE 316

11

12. Body

RN / ST ST / Ductile Iron

12

13.

Float

Foamed Polypropylene

14.

O-Ring

BUNA-N

13

15. Clamp

R.N. Body

Reinforced Nylon

9
10

14
15

+ Stainless Steel SAE 316

ST ST / DI Body

Stainless Steel SAE 316

16

16. Ball Valve

Stainless Steel SAE 316

17

17. Base

RN / ST ST / Ductile Iron

D-025-SB
Sample Installation Scheme

Important Information: Prior to site preparation and installation,


please refer to the D-025 SB Installation and Maintenance Manual
for all the relevant instructions and information. The manual can be
obtained by contacting the A.R.I marketing dept., from your local
A.R.I. distributor or downloading the file from our website.

DIMENSIONS AND WEIGHTS


Model

Dimensions

Weight Kg.

Orifice Area mm2

RN Body

Auto.

A/V

L800

448

970

875

806

36.3

12

804

L1000

448

1170

1075

1006

39.3

12

804

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-026

Wastewater

PN 16

Combination Air Valve for Wastewater


Description

The D-026 Combination Air Valve combines an air & vacuum orifice
and an air release orifice in a single body. The valve is specially designed to
operate with liquids carrying solid particles such as wastewater and effluents.
The combination air valve discharges air (gases) during the filling or charging
of the system, admits air into the system while it is being emptied of liquid
and releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the separation
of the liquid from the sealing mechanism and assures optimum working
conditions.

Applications

- Pump stations for sewage, wastewater and water treatment plants.


- Sewage water, effluent water and sea water supply lines.

Operation

The air & vacuum component discharges air at high flow rates during the
filling of the system and admits air into the system at high flow rates during
its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the float which
seals the valve. At any time during system operation, should internal pressure
of the system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other destructive
phenomena.
The intake of air in response to negative pressure protects the system from
destructive vacuum conditions and prevents damage caused by water column
separation. Air entry is essential to efficiently drain the system. The air release
component releases entrapped air in pressurized systems.
Without air valves, pockets of accumulated air may cause the following
hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a partially
closed valve. In extreme cases this will cause complete flow stoppage.
- Obstruction of efficient hydraulic transmission due to air flow disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of high-energy bursts of compressed air.
- Inaccuracies in flow metering.

EnC-D026SWG-11 187

As the system starts to fill, the combination wastewater valve functions


according to the following stages:
1. Entrapped air/gas is discharged by the valve
2. When the liquid level reaches the valves lower portion, the lower float is
lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid and the
sealing mechanism. The air pressure is equal to the system pressure.
4. Increases in system pressure compress the trapped air in the upper section
of the conical chamber. The conical shape assures the height of the air gap.
This enables complete separation of the liquid from the sealing mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system, rises to
the top of the valve, and displaces the liquid in the valves body.
6. When the liquid level is lowered to a point where the float is no longer
buoyant, the float drops, unsealing the rolling seal. The air release orifice
opens and allows part of the air that accumulated in the upper portion of the
valve to be released to the atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to its

sealing position. The remaining air gap prevents the wastewater from fouling
the mechanism.
When internal pressure falls below atmospheric pressure (negative
pressure):
1. The floats will immediately drop down, opening the air & vacuum and air
release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.2 - 16 bar.


- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the wastewater
and the sealing mechanism by creating an air gap at the top of the valve.
These features are achieved by:
The conical body shape and the external rod: designed to maintain the
maximum distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Spring loaded joint between the stem and the upper float: vibrations of
the lower float will not unseal the automatic valve. Release of air will occur
only after enough air accumulates.
Funnel-shaped lower body: designed to ensure that residue wastewater
matter will fall back into the system and be carried away by the main pipe.
The Rolling Seal Mechanism: less sensitive to pressure differentials than a
direct float seal. It accomplishes this by having a comparably large orifice for
a wide pressure range (up to 16 bar).
- All inner metal parts made of stainless steel.
- Unique design prevents contact between the wastewater and the sealing
mechanism, prevents clogging by floating solids and ensures drip-tight
sealing.
- The D-026 orifice plug-disc linkage assembly is external, keeping the rod
and pins outside the air valve body and its corrosive atmosphere.
- Discharge outlet enables removal of excess fluids
- 1 ball valve releases trapped pressure and drains the valve body prior to
maintenance.

Valve Selection

- Size availability: 6, 8.
- Valve manufactured with flanged ends to meet any requested standard.
- Valve body coating: fusion bonded epoxy coating according to the standard
DIN 30677-2.
- Standard metal body and polyethylene cover, also available with a ST. ST.
body and polyethylene cover.
- An optional Non-Slam discharge-throttling attachment (see drawing on
next page), allows for free air intake, throttles air discharge.
- Additional coatings including Halar are available upon request.

Note

- The D-026 air valve is intended for use with raw wastewater. For use with
aggressive liquids, please consult with our application engineers or with the
marketing dept.
- For best suitability, it is recommended to send the fluid chemical properties
along with the valve request.
- Upon ordering, please specify: model, size, working pressure, threads
standard and type of liquid.

D-026
DIMENSIONS AND WEIGHTS
Model

Nominal

Connection

Weight

D-026

6 (150 mm)

448

Auto.

A/V

958

6 Fl./Vic.

80.6

32

17663

D-026

8 (200 mm)

448

958

6 Fl./Vic.

83.6

32

17663

D-026 NS
D-026 NS

6 (150 mm)

448

1066

6 Fl./Vic.

85.4

32

17663

8 (200 mm)

448

1066

6 Fl./Vic.

88.4

32

17663

Size

Dimensions mm

Kg.

Orifice Area mm2

PARTS LIST AND SPECIFICATION D-026 / D-026 NS models


No.

Part

Material

1.

Flange Supports

Stainless Steel SAE 304

2.

Victaulic Connection

3.

Elbow Discharge Outlet

Polyethylene

4.

Domed Nut, Washer


& Spring Washer

Stainless Steel SAE 316 + 304

5.

Nut, Spring Washer & Washer

Stainless Steel SAE 316 + 304

6.

Threaded Rod

Stainless Steel SAE 316

7.

Spring, Washer, Nut

Stainless Steel SAE 316

8.

Sealing Assembly Guide Rod

Stainless Steel SAE 316

9.

Bolt, Washer, Nut

Stainless Steel SAE 316

18

10.

Air & Vacuum Seat

Stainless Steel SAE 316

19

11.

Air & Vacuum Sealing Assembly

RN + Stainless Steel SAE 316 + EPDM

20

12.

Air Release Sealing Assembly

RN + Stainless Steel SAE 316 + EPDM

21

13.

Float Assembly

Polycarbonate/Stainless Steel 316


+ Stainless Steel 316

14.

Body

Ductile Iron ASTM A-536-60-40-18

15*

Non Slam Disc

Ductile Iron ASTM A-536-60-40-18

16*

Disc Housing Cover

Steel St 37

17*

Disc Housing

Steel St 37

13
14

18.

Lifting Ring

Stainless Steel SAE 316

19.

Bridge Assembly

Stainless Steel SAE 316 + Aucolon

20.

Cover

Ductile Iron ASTM A-536-60-40-18

21.

O-Ring

BUNA-N

22.

Ball Valve 1

Stainless Steel SAE 316

NON SLAM ADITION - OPTIONAL

D-026

D-026 NS

1
15
16
17

2
3
4
5
6
7
8
9
10
11
12

22

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

K-020
K-022

PN 16

Wastewater

PN 25

Air & Vacuum Valve


Description

The K-020 & K-022 Air & Vacuum Valves are specially designed
to operate with liquids carrying solid particles such as wastewater
and effluents. These air & vacuum valves discharge air (gases) during
the filling or charging of the system and admit air into the system
while it is being emptied of liquid. The valves unique design enables
the separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

-Pump stations for sewage, wastewater & water treatment plants.


-Wastewater, effluent water and sea water supply lines.

Operation

The K-020 & K-022 air & vacuum valves discharge air at high flow
rates during the filling of the system and admit air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused by
water column separation. Air entry is essential to efficiently drain
the system.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air/gas is discharged by the valve
2. When the liquid level reaches the valves lower portion, the float
is
lifted, pushing the sealing mechanism to its sealing position.
EnC-K-020SWG-11 189

When internal pressure falls below atmospheric pressure


(negative
pressure):
1. The floats will immediately drop down, opening the air &
vacuum
orifice.
2. Air will enter the system.

Main Features

- Working pressure range: K-020 0.2 - 16 bar.


K-022 0.2 - 25 bar
- Testing Pressure: 1.5 times the working pressure of the air valve.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The valves unique design prevents contact between the wastewater
and the sealing mechanism by creating an air gap at the top of the
valve. Those features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
-Flushing is possible while the valve is under pressure by opening the
ball valve in the valves lower part.

Valve Selection

- Size range: 3 - 4.
- These valves are manufactured with flanged ends to meet any
requested standard.
- Standard metal body, also available with a stainless steel body.
- Air valve coating: fusion bonded epoxy according to standard
DIN 30677-2.
- Other coatings are available upon request.
- Optional Accessories
With a One-Way, Out-only attachment, allows for air discharge
only, prevents air intake.
With a Vacuum Breaker, In-only attachment, allows for air intake
only, prevents air discharge.
With a Non-Slam discharge-throttling attachment, allows for free
air intake, throttles air discharge.

Note

- The K-020 air valve is intended for use with raw wastewater. For
use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

K-020

DIMENSIONS AND WEIGHTS


Nominal

Size

Dimensions mm
A

3 (80mm)

465

4 (100mm)

465

Connection

Weight Kg.

Orifice Area

STEEL

ST ST

mm2

783

3 BSP Female

24.5

26

5026

783

3 BSP Female

26

27

5026

PARTS LIST AND SPECIFICATION

No. Part

Material

1. Discharge Outlet

PVC / Stainless Steel

2. Domed Nut

Stainless Steel SAE 316

3. Washer

Stainless Steel SAE 316

4. Bushing

Teflon

5. Cover

Cast Iron ASTM A48 CL35B

/ Stainless Steel ASTM A744 CF8M

6. Stem + Spherical Flap

Stainless Steel SAE 316

7. Orifice Seat

Bronze / Stainless Steel SAE 316

8. Orifice Seal

E.P.D.M. + Bronze

9. Bolt & Nut

Stainless Steel SAE 316

10

10. O-ring

BUNA-N

11

11. Joint

Stainless Steel SAE 316

12. Pin

Stainless Steel SAE 316

12

13. Stem + Float

Stainless Steel SAE 316

14. Ball Valve 1

Brass / Stainless Steel

15. Body

Steel Din St.37 / ST ST SAE 316

3
4

7
8
9

13

14
15

K-022

DIMENSIONS AND WEIGHTS


Nominal
Size

Dimensions mm
B

internal

Weight Kg.
Kg.

Orifice Area

external

mm2

3 (80mm)

470

730

63.5

74.6

42.0

1809

4 (100mm)

470

730

63.5

74.6

43.8

1809
1
2
3

PARTS LIST AND SPECIFICATION

4
5

EnC-K-020SWG-11 191

No. Part

Material

1. Lifting Ring

Stainless Steel SAE 304

2. Washer

Stainless Steel SAE 316

3. Spring Holder

Stainless Steel SAE 316

4. Plug

Brass / Stainless Steel

5. Spring

Stainless Steel SAE 316

10

6. Cover

Ductile Iron ASTM A-536-60-40-18

11

/ Stainless Steel SAE 316 / 317

7. Orifice Seat

Bronze / Stainless Steel SAE 316

8. Orifice Seal

E.P.D.M.

9. O-Ring

BUNA-N

10. Nut

Stainless Steel SAE 316

11. Bolt

Stainless Steel SAE 316

16

12. Upper Float Assembly Stainless Steel SAE 316

17

13. Bolt

18

6
7
8

12

13
14
15

Stainless Steel SAE 316

14. Air & Vacuum Body Ductile Iron ASTM A536 60-40-18

/ Stainless Steel SAE 316

15. O-Ring

BUNA-N

16. Float Assembly

Polycarbonate + Stainless Steel SAE 316 Rod

17. Ball Valve 1

Stainless Steel SAE 316

18. Body

Steel DIN St.37 / Stainless Steel SAE 316

S-020
S-022

Wastewater

PN 16
PN 25

Automatic Air Release Valve for Wastewater


Description

The S-020 and S-022 Automatic Air Release Valves are specially
designed to operate with liquids carrying solid particles such as
wastewater and effluent.
The valves release accumulated air (gases) from the system while
under pressure and operating.
The valves unique design enables the separation of the liquid from
the sealing mechanism and assures optimum working conditions.
The presence of air in a wastewater system can reduce the effective
cross sectional flow area, resulting in increased head loss and
decreased flow.
Unwanted air may also cause water hammer and metering
inaccuracies, while hastening corrosion.

Applications

- Pump stations for sewage, wastewater & water treatment plants.


- Wastewater, effluent water and sea water supply lines.

Operation

EnC-S020SWG-11 193

A.R.I. models S-020, S-022 are air release valves for wastewater
systems.
As the system starts to fill, the automatic air release valve
functions according to the following stages:
1. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
2. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
3. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
4. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
5. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
6. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
Note: Automatic air release valves are designed to release air as it
accumulates at peaks in pressurized systems. They are not normally
recommended for vacuum protection or for discharging large
volumes of air, because of their inherently small orifices. For this

purpose, air & vacuum valves are recommended as they have much
larger orifices.
However, air release valves will permit air to enter the system under
vacuum conditions. If this is not desirable, specify the one-way out
check valve.

Main Features

- Working pressure range: S-020 0.2 - 16 bar, S-022 0.2 - 25 bar


- Testing pressure: S-020 25 bar, S-022 40 bar
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Spring-loaded joint between the stem and the upper float:
vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
Rolling seal: provides smooth positive opening, closing, and leak
free sealing over a wide range of pressure differentials.
- Internal metal parts: made of corrosion resistant stainless steel.
- Threaded discharge outlet enables removal of excess fluids.
- 1 ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- Size range: 2 4.
- These valves are manufactured with flanged ends to meet any
requested standard
- The 2 valve is also available with a BSP or NPT male threaded
connection.
- Standard metal body, also available with a stainless steel body.
- Valve body coating: fusion bonded epoxy coating according to the
standard DIN 30677-2.
- Other coatings are available upon request.
- Available in S-020 - PN16, S-022 - PN25.

S-020 / S-022
Note

- The S-020, S-022 air valves are intended for use with raw
wastewater. For use with aggressive liquids, please consult with our
application engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

S-020
DIMENSIONS AND WEIGHT
Nominal

Dimensions mm

Connection

Weight

Orifice Area

575

1/8 BSP Female

16

12

463

575

1/8 BSP Female

17

12

463

575

1/8 BSP Female

17

12

3 (80 mm) Flanged

463

575

1/8 BSP Female

18

12

4 (100 mm)

463

575

1/8 BSP Female

19

12

Size

2 (50 mm) Threaded

463

2 (50 mm) Flanged


3 (80 mm) Threaded

Kg.

mm2

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M

1
2
3

4
5

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. Bolt,Nut & Washer

Stainless Steel SAE 316

7. Cover

Reinforced Nylon

8. Domed Nut

Stainless Steel SAE 304

9. Washer

Stainless Steel SAE 316

10. Stopper

Polypropylene

11. O-ring

BUNA-N

12. Spring

Stainless Steel SAE 316

13. Washer

Stainless Steel SAE 316

14

14. O-ring

BUNA-N

15

15. Float Assembly

Polycarbonate

+ Stainless Steel SAE 316

16. Ball Valve 1

Brass, Chrome Coated

17. Body

2, 4 - 8

Steel DIN St.37 / ST ST SAE 316

Steel DIN St.37 / ST ST SAE 316

/ Steel A216 WCB

/ ST ST ASTM A744 CF8M

9
10

11
12
13

16
17

EnC-S020SWG-11 195

S-022
DIMENSIONS AND WEIGHT
Nominal

Dimensions mm

Connection

Weight

Orifice Area

593

1/8 BSP Female

17

463

593

1/8 BSP Female

18

463

593

1/8 BSP Female

18

3 (80 mm) Flanged

463

593

1/8 BSP Female

19

4 (100 mm)

463

593

1/8 BSP Female

20

Size

2 (50 mm) Threaded

463

2 (50 mm) Flanged


3 (80 mm) Threaded

Kg.

mm2

PARTS LIST AND SPECIFICATION

No. Part

Material

1. Shell

Ductile Iron

2. Body

Reinforced Nylon

3. Discharge Outlet

Brass

4. Rolling Seal

E.P.D.M

5. Clamping Stem

Reinforced Nylon

6. Float

Foamed Polypropylene

7. Cover

Steel DIN St.38 / ST ST SAE 316

12. O-Ring

BUNA-N

8. Domed Nut

Stainless Steel SAE 304

9. Washer

Stainless Steel SAE 316

10. Stopper

Polypropylene

11. Spring

Stainless Steel SAE 316

13. Bolt, Nut & Washer

Stainless Steel SAE 316

10

14. Ball Valve 1

Brass Chrome Coated

/ ST ST SAE 316 / 317

15. Float Assembly

Polycarbonate / ST ST

+ Stainless Steel SAE 316 / 317

16. Body

4 - 8

Steel DIN St.37 / ST ST SAE 316

2,3

Steel DIN St.37 / ST ST SAE 316

/ Steel A216 WCB

/ ST ST ASTM A744 CF8M

1
12

2
3
4
5
6
7

* The float in the drawing is made of St.St.

11
13

14
15
16

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

S-021

Reclaimed Water

PN 10

Automatic Air Release Valve


for Reclaimed and Non-Potable Water
Description

The S-021 Automatic Air Release Valve is specially designed to


operate with liquids carrying solid particles.
The automatic air release valve releases accumulated air from the
system while it is under pressure.
The valves unique design enables the separation of the liquid from
the sealing mechanism and assures optimum working conditions.
The presence of air in a reclaimed and non-potable water system can
reduce the effective cross sectional flow area, resulting in increased
head loss and decreased flow.
Unwanted air may also cause water hammer and metering
inaccuracies, while hastening corrosion.

Applications

- Reclaimed water
- Raw water
- Effluent water
- Water with suspended solids
- Coolant water

Operation

EnC-S021SWG-11 197

The S-021 is an air release valve for reclaimed and non-potable


water systems.
As the system starts to fill, the automatic air release valve
functions according to the following stages:
1. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
2. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
3. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
4. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
5. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
6. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.

Note: the automatic air valves are specifically designed to release


air as it accumulates at the high points of a pressurized, operating
system. Because of their inherently small orifice size, they are not
recommended for vacuum protection or for discharging large
quantities of air or gas, although they will admit some air into the
system under vacuum conditions.

Main Features

- Working pressure range: 0.2 - 10 bar


- Testing pressure: 16 bar
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Body made of composite plastic material, resistant to corrosion.
- Internal metal parts are made of corrosion-resistant stainless steel.
- Floats are made of composite materials.
- Flexible rolling seal provides smooth positive opening, closing, and
leak-free sealing over a wide range of pressure differentials.
- 1/8 threaded discharge outlet enables removal of excess fluids.
- Drainage tap with ball valve is provided.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
Rolling Seal: provides smooth positive opening, closing, and leakfree sealing over a wide range of pressure differentials.
- 1/4 ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- Size Range: 1& 2, BSP or NPT male threaded connection or


flanged to meet any requested standard.
- Flanges are manufactured of composite materials.
- Additional one-way out check valve attachment allows air
discharge, not allowing air intake.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.

S-021
Note

- The S-021 air valve is intended for use with raw wastewater. For
use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

DIMENSIONS AND WEIGHTS


Nominal

Size

Dimensions mm

Connection

Weight

Orifice Area

Kg.

mm2

1 (50mm)

216

324

1/8 BSP Female

1.78

12

2 (80mm)

216

324

1/8 BSP Female

1.78

12

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M.

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Body

Reinforced Nylon

8. Float Stem

Stainless Steel SAE 316

9. Clamp

Reinforced Nylon

+ Stainless Steel SAE 316

10. O-Ring

BUNA-N

11. Float

Foamed Polypropylene

12. Base

Reinforced Nylon

13. Ball Valve 1/4

Brass, Nickel Plated

2
3
4
5
6
7

8
9
10
11
12
13

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

S-025

Wastewater

PN 10

Automatic Air Release Valve for Wastewater - Short Version


Description

The S-025 Automatic Air Release Valve is specially designed to


operate with liquids carrying solid particles such as wastewater and
effluent.
The valves unique design enables the separation of the liquid from the
sealing mechanism and assures optimum working conditions.
The valve releases accumulated air (gases) from the system while
under pressure and operating.
The presence of air in a wastewater system can reduce the effective
cross sectional flow area, resulting in increased head loss and
decreased flow.
Unwanted air may also cause water hammer and metering
inaccuracies, while hastening corrosion.

Applications

- Pump stations for sewage, wastewater & water treatment plants.


- Wastewater, effluent water and seawater supply lines.

Operation

EnC-S025SWG-11 199

A.R.I. model S-025 is an air release valve for wastewater systems.


As the system starts to fill, the automatic air release valve functions
according to the following stages:
1. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
2. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
3. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
4. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves body.
5. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in the
upper portion of the valve to be released to the atmosphere.
6. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
Note: Automatic air release valves are designed to release air as it
accumulates at peaks in pressurized systems. They are not normally
recommended for vacuum protection or for discharging large volumes
of air, because of their inherently small orifices. For this purpose, air
& vacuum valves are recommended as they have much larger orifices.
However, air release valves will permit air to enter the system under

vacuum conditions. If this is not desirable, specify the one-way out


check valve.

Main Features

- Working pressure range: 0.2 - 10 bar


- Testing pressure: 16 bar
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still obtain
minimum body length.
Spring-loaded joint between the stem and the upper float:
vibrations of the lower float will not unseal the air release component.
Release of air will occur only after enough air accumulates.
The Rolling Seal Mechanism: less sensitive to pressure differentials
than a direct float seal. It accomplishes this by having a comparably
large orifice for a wide pressure range (up to 10 bar).
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- All inner metal parts made of stainless steel. Float made of composite
materials.
- Threaded discharge outlet enables removal of excess fluids.
- 1/4 ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- These valves are available in 2,with a BSP/NPT male threaded


connection or flanged ends to meet ASA 150 standard or any requested
standard.
- With a One-way, Out-only attachment, allows for air release only,
prevents air intake.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.

Note

- The S-025 air valve is intended for use with raw wastewater. For use
with aggressive liquids, please consult with our application engineers
or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure, threads
standard and type of liquid.

S-025
DIMENSIONS AND WEIGHTS
Nominal

Size

Dimensions mm

Connection

Weight

Orifice Area

424

1/8 BSP Female

3.8

12

429

1/8 BSP Female

4.2

12

2 (80mm) Threaded

246

2 (80mm) Flanged

246

Kg.

mm2

PARTS LIST AND SPECIFICATION

No. Part

Material

1. Discharge Outlet

Polypropylene

2. Rolling Seal

E.P.D.M.

3. Body

Reinforced Nylon

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Adaptor

Acetal

8. O-Ring

BUNA-N

9. Body

Reinforced Nylon

10. Float Assembly

Stainless Steel SAE 316

+ Foamed Polypropylene

11. Clamp

Reinforced Nylon

+ Stainless Steel SAE 316

12. Base

Reinforced Nylon

13. Ball Valve 1/4

Brass, Nickel Plated

3
4

8
9
10
11
12
13

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

S-025-SB

Wastewater

PN 10

Underground Air Valve System for Wastewater


Description

The S-025 SB is a complete product package that combines the


reliable and efficient properties of the A.R.I. S-025 automatic air
release wastewater valve with the added feature of a sub-surface
valve that can be buried below ground. A specially designed gear
box operated horizontal sliding disc valve - situated at the base of
the S-025 SB assembly - allows for the air valve disconnection and
maintenance from ground level.
This gear box operated shut-off valve is equipped with a safety
mechanism enabling disconnection and removal of the S-025 air
valve from its subsurface housing, even when the system is under
pressure. Since service and maintenance operations of the unit are
performed entirely from the surface, there is no need for safety
considerations associated with confined space entry.
The S-025 Automatic Air Release Valves are specially designed to
operate with liquids carrying solid particles such as wastewater and
effluent. The valves release accumulated air (gases) from the system
while under pressure and operating. The valves unique design
enables the separation of the liquid from the sealing mechanism and
assures optimum working conditions.

Applications

- Underground municipal and industrial wastewater and effluent


pressurized pipelines.
- Underground pressurized pipelines conveying liquids with
suspended solids and grime.

Operation

EnC-s025SBSWG-11 201

As the system starts to fill, the automatic air release valve functions
according to the following stages:
1. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
2. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
3. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
4. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve and displaces the liquid in the valves
body.
5. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.

6. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
Note: Automatic air release valves are designed to release air as it
accumulates at peaks in pressurized systems. They are not normally
recommended for vacuum protection or for discharging large
volumes of air, because of their inherently small orifices. For this
purpose, air & vacuum valves are recommended as they have much
larger orifices.
However, air release valves will permit air to enter the system under
vacuum conditions. If this is not desirable, specify the one-way out
check valve.

Main Features

S-025 SB Underground Air Valve System for


Wastewater:

- The S-025 SB incorporates an integral, flat, gear box operated


horizontal sliding disc valve with a 3 full bore passage.
- The shut-off valve is operated from the surface.
- Easy and efficient back flushing can be achieved while the air valve
is in its sub-surface housing.
- All connections utilize quick connectors to facilitate easy usage
during:
1. Handling (quick connector from adaptor to shut-off valve)
2. Maintenance operations (quick connectors on both the inlet &
outlet flushing positions).
-Safety elements: Disengaging the air valve is safeguarded: unless the
shut-off valve is in the closed position and the internal pressure is
released, it is not possible to extract the air valve.
- Pipe connections: 3 threaded (BSP/NPT) or flanged, in
accordance with all standards.
- All parts are corrosion resistant: Metal parts made of Stainless
Steel, Ductile Iron or steel, Composite material parts made of
Nylon, PA, and PVC
- Drainage system: a special one-way valve that drains the water
from the valve box and does not admit water.
S-025 Combination Wastewater Air Valve:
- Working pressure range: 0.2 - 10 bar.
- Testing pressure: 16 bar.
- Maximum working temperature: 60 C.

S-025-SB
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
1. The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
2. Spring-loaded joint between the stem and the upper
float: vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.
3. The Rolling Seal mechanism: less sensitive to pressure
differentials than a direct float seal. It accomplishes this by having a
comparably large orifice for a wide pressure range (up to 10 bar).
4. Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- All inner metal parts made of stainless steel. Float made of
composite materials.

Advantages and Benefits


- Relatively lightweight and convenient to install.
- Sub-surface installation.
- Low installation costs:
1. No need for expensive, large excavation.
2. No need for expensive, human-accessible manholes.
- Low maintenance costs:
1. No need for specialized tools or safety equipment.
2. One person for operation and maintenance.
3. Clean and environmentally friendly.

4. Complete service and maintenance system, including an integral


disassembly mechanism to ensure easy back flushing and servicing,
while reducing the need for spare changeable valves.
- Safe in operation:
1. Greatly reduces the danger of contact with local fauna snakes
and scorpions, etc!
2. Entirely operated and maintained from ground level.
- Reliable and efficient operation:
1. Dynamic design allows high velocity air discharge while
preventing premature closure.
2. A.R.I. patented Rolling Seal mechanism.
3. Since the valve is a sub-surface (underground), it is more resistant
to frost conditions.

Valve Selection
- Two different installation lengths:
1. 800 mm tube; complete system length: 875 mm.
2. 1000 mm tube; complete system length: 1075 mm.
- Air valve body: Composite Materials or Stainless Steel SAE 316.
- Additional Accessories:
With a One-way, Out-only attachment, allows for air discharge
only, prevents air intake.

Note

- The S-025 SB air valve is intended for use with raw wastewater.
For use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

S-025-SB
UNDERGROUND AIR VALVE SYSTEM
PARTS LIST AND SPECIFICATION
No Part

Material

1.

Valve Box Cover

Polyethylene

2.

Ball Valve 1 1/2"

Stainless Steel SAE 304

3.

Pressure Relief Valve

Stainless Steel SAE 316

4.

Lifting Handle

Stainless Steel SAE 304

5.

Back Flushing Assembly

Polyethylene

6.

Operating Rod

Stainless Steel SAE 304

7.

S-025 Air Valve

see below

8.

Sliding Disc Valve w / Gear Box

DI+STST+E.P.D.M.

/STST+STST+E.P.D.M.

9.

Stainless Steel SAE 316

Adaptor - Quick Connector 3

10. Safety Handle

Stainless Steel SAE 316

11. T Key

Stainless Steel SAE 304

12. Valve Box

Polyethylene

13. Flange 3

Reinforced Nylon

/Stainless Steel SAE 316

1
2
3
4
5
6
7
8
9
10
11
12
13

S-025 PARTS LIST AND SPECIFICATION

EnC-s025SBSWG-11 203

No. Part

Material

1. Discharge Outlet

Polypropylene

2. Rolling Seal

Rubber E.P.D.M.

3. Body

Reinforced Nylon

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Adaptor

Acetal

8. O-Ring

BUNA-N

9. Body

Stainless Steel SAE 316 / Reinforced Nylon

10. Float Assembly

Stainless Steel SAE 316 + Foamed Polypropylene

11. Clamp

Reinforced Nylon + Stainless Steel SAE 316

12. Base

Stainless Steel SAE 316 / Reinforced Nylon

13. Ball Valve 1

Brass, Nickel Plated

3
4
5
6
7

8
9
10
11
12
13

S-025-SB
Sample Installation Scheme

DIMENSIONS AND WEIGHTS

Model Dimensions
Weight
Orifice Area

A B C
Kg.
mm2
L800

448

806

875

L1000

448 1006 1075

35.5

12

38.5

12

Important Information: Prior to site preparation and installation,


please refer to the S-025 SB Installation and Maintenance Manual
for all the relevant instructions and information. The manual can be
obtained by contacting the A.R.I marketing dept., from your local
A.R.I. distributor or downloading the file from our website.

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

SD-010 GB

Wastewater

Gear Box Driven Horizontal Sliding Disc Valve


Description

A.R.I. model SD-010GB is a 3" inlet, gear box driven horizontal


sliding disc valve designed for underground and confined space
installations. The gear box is activated by a vertical operating rod
(enables above ground operation of underground installations).
The valve provides fluid-tight sealing up to 25 bar (365 psi) working
pressure and is installed horizontally between the pipeline and the
user's device.
Integral to the valve is either a 2" or 3" threaded or quick
connection adaptor outlet. The 3" adaptor has an additional 1 "
BSP female threaded orifice perpendicular to its vertical access,
which can be used as a flushing outlet.
The quick connection adaptor has a built in safety mechanism to
prevent the accidental removal of the user's device while there is
open flow through the valve. The disc valve must be in the closed
position before the user's device can be disconnected from the quick
connection adaptor.

Applications

- Underground installations of air valves.


- Installation of air valves and valves in confined spaces.
- Fire hydrants.
- Municipal services.
- Wastewater manholes.

Operation

The valves unique design allows for operation from above, thus
enabling its use in underground and confined space applications.
An operating rod attached to the gear box from above activates the
opening and closing of the valve.
The integral 2" or 3" adaptor provides a safety mechanism that
prevents the disconnection of the adaptor and the users' device from
the horizontal disc valve when the disc valve is in the open position.

EnC-SD010GBSWG-11 205

Main Features

- Working Pressure : 16 bar, 25 bar


- Low profile enables installation in confined spaces.
- Integral 2" or 3" adaptor - quick connection and added safety
element.
- Operating rod - length upon request.

Outlet Options

Threaded Outlet Housing


2", 3" - BSP/NPT made of stainless steel.
Adaptor Housing + Adaptor w/Outlet
2" NPSM outlet, made of ductile iron.
3" BSP/NPT outlet made of ductile iron or stainless steel, with a
threaded Flushing Outlet 1" BSP.

Accessories

- T Handle Operating Rod


Made of Stainless Steel SAE 304
Length - upon request

SD-010 GB
PARTS LIST AND SPECIFICATION

DIMENSIONS AND WEIGHTS

No Part

Material

1.

Screw

Stainless Steel SAE 304

2.

Upper Body

Ductile Iron /Stainless Steel

3.

Upper Gasket

Teflon

4.

Body Gasket

E.P.D.M.

5.

Plate

Stainless Steel SAE 304

6.

Lower Body

Ductile Iron /Stainless Steel

7.

Lower Gasket

E.P.D.M. / St.St.SAE 304

8.

Operating Axis

Stainless Steel SAE 304

9.

"T" Handle

Stainless Steel SAE 304

10. Operating Rod

Dimensions mm.
A

279.4

327.66

Connection

Weight

3" NPT/BSPT Male

18

Kg.

Stainless Steel SAE 304

2" NPSM

1.5 BSP
3" BSP/NPT

GEAR BOX
PRESSURE RELIEF VALVE PLUG

PIN

3"

9
10

2"
1

2
3

C
A

4
5
6
7

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

ODOR

Wastewater

Odor Control Screen Assembly for Wastewater Air Valves


A.R.I. Flow Control Accessories is proud to introduce a new innovative solution for odor control in wastewater systems.
The special assembled unit can be installed on the A.R.I. combination air valves for wastewater.
The unit absorbs the noxious odors emitted from a wastewater system which are a nuisance both in the residential as well
as in the work environment.
The odor control screen assembly can be installed on A.R.I. wastewater air valve models D-020, D-025, D-023.
The unit is both portable and disposable.
No heavy equipment is needed and there is no messy disposal of spent carbon.

Filter Model
Maximal Flow Capacity
Outlet
Dimensions
Weight

1214

1620

1630

200/350 m3h

420/713 m3h

600/1000 m3h

2 2 2
30x32.5 cm

41.25x49.25 cm

41.25x73.75 cm

7 Kg.

18 Kg.

27 Kg.

EnC-D025SWG-11 207

ODOR
Installation of Odor Control Screen Assembly

Check valve One Way Out

Threaded "T" 1"

Socket Threaded 1"


Threaded Hose Nozzle 1"

Check valve One Way In


Socket Threaded 1
Screen Assembly

Male Threaded Coupler -B 1" BSP

Combination Air Valve


For Wastewater
D-020 / D-025

Hose

Clamp
Coupler Hose Type C

Filter

3 Pipe

Concrete Support Block

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

NR-040
NR-042
NR-044
NR-064

PN 16

Wastewater

PN 25
PN 40
PN 64

Check Valve with Removable Cover


Description

- Fusion bonded epoxy coating according to standard


DIN 30677-2.
- Removable top cover allows for easy cleaning, maintenance, and
seat replacement and eliminates the need to remove the valve from
the system.
- Can be installed in either a horizontal or vertical position
(vertically, only when the flow rate is in an upward direction and a
counterweight is installed).
- Stainless steel extended shaft on both sides of the valve body.

Applications

- Size range 3"-40"


- Available in pressure ratings of 16 bar (Cast Iron Body / Ductile
Iron), 25 bar (Ductile Iron Body), 40 and 64 bar (Cast Steel Body).
- Flanges are available in BS/ISO/ANSI standards.
- Can be adapted to various types of liquid upon request.
- Options:
A. Bronze on bronze or stainless steel on stainless steel disc and
seat seal for adverse working conditions.
B. Available with enamel-coated body or stainless steel body.
C. Additional counterweight for slam protection and/or
NR-040 LS electric limit switch indicator for transmitting a flow/
no flow signal.
D. Hydraulic Controlled Check Valve NR-040-HC is available.
-For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.

The NR-040 series Swing-Type Check Valve allows for onedirectional flow and prevents the return flow of the liquid to its
source.
The check valve is designed with a removable top cover which allows
for cleaning and maintenance of the check valve without the need to
remove it from the pipeline.
The disc is attached to the check valve body with the aid of an arm.
The check valve seals with the closure of the disc against the sealing
ring which is located at the opening of the check valve body.

- Pump stations for potable water and wastewater


- Filtration systems
- Service line connections to the main line

Operation

EnC-NR040WTR-11 209

- Liquid flow through the check valve raises the disc to its open
position and allows for the flow of liquids to the pipeline.
- Two Possible Situations for Disc Closure
1. Regular quiet closure of the disc.
2. Closure during the return flow of the water column, a situation
that can cause slam of the disc and damage to the check valve.
- In order to prevent this destructive phenomenon, it is
recommended to install a counterweight on the shaft of the check
valve. With this addition, the disc will close at the point of water
flow cessation and before the water column returns. The returning
wave will impact on a closed disc and the acceleration of the disc
closure will result in a minimal slam effect.
- Another option is to install a hydraulic piston to control the
closure of the disc.

Main Features

- Maximum working temperature: 60 C.


- Maximum intermittent temperature: 90 C.
- Surge-resistant cast iron body.
- Bronze or ductile iron disc with natural rubber flap seal, seals at
low pressures and eliminates wear and tear of the flap.
- Corrosion-resistant inner parts ensure long term service under
adverse conditions.

Valve Selection

Note

- The NR-040 Check valve is intended for use with raw wastewater.
For use with aggressive liquids, please consult with our application
engineers or with the marketing dept.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
- Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

NR-040
PARTS LIST AND SPECIFICATIONS
No. Part

Material

1.

Counterweight

Cast Iron / Steel

2.

Lifting Ring

Steel

3.

Cover

Ductile Iron ASTM A-536-50-40-18

4.

Bolt, Nut & Washer Steel Zinc Cobalt Coated

5.

Cover O-Ring

BUNA-N

6.

Body

Cast Iron / Ductile Iron

7.

Cotter Pin

Stainless Steel SAE 304

8.

Arm Pin

Stainless Steel SAE 303

9.

Arm

Bronze ASTM B-62 / Ductile Iron

10. Disc

Bronze ASTM B-62 + Natural & Synthetic Rubber

/ Ductile Iron + Natural & Synthetic Rubber

11. Bolt

Stainless Steel SAE 304

12. Sealing Ring

Bronze ASTM B-62

/ Stainless Steel on Bronze ASTM B-62

/ Stainless Steel on Stainless Steel

13. Stopper

Natural & Synthetic Rubber

14. Shaft

Stainless Steel SAE 303

15. Plug Bolt

Stainless Steel SAE 304

16. Plug O-Ring

BUNA-N

17.

Stainless Steel

Bearing

18. Spacer

Brass ASTM B-124

19. Disc Arm Key

Stainless Steel SAE 303

20. Plug

Brass ASTM B-124

14

15

16

17

18

19

20

D
1
2
3
4

DIMENSIONS AND WEIGHTS

Nominal Dimensions mm
Weight
Size
A B C D Kg.
3 (80 mm) 242 252 316 300 20.0
4 (100 mm) 262 280 347 320 28.5
6 (150 mm) 356 360 505 400 57.0

6
7

8 (200 mm) 420 453 638 500 101.0

10

10 (250 mm) 479 537 670 550 166.0

11

12 (300 mm) 553 622 727 600 242.5

12

14 (350 mm) 838 701 862 700 352.0

13

16 (400 mm) 760 734 910 700 364.0


18 (450 mm)

978

880

1210

860

756.0

20 (500 mm)

865

892

1110

1000

640.0

24 (550 mm) 1295 1090 1320 1120 1239.0


28 (650 mm) 1448 1312 1700 1310 1670.0
30 (700 mm) 1750 1370 1905 1310 1886.0
32 (750 mm) 1850 1374 1783 1300 2200.0
36 (800 mm) 1956 1504 1985 1410 2500.0
40 (900 mm) 2250 1680 2090 1500 3350.0

NR-040

EnC-NR040WTR-11 211

VALVES FOR AGRICULTURAL APPLICATIONS

0304-ENNB-AGR-11

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988

Agriculture

Recommendations

AV-010

Installations Guide

SG-10 / S-050

DG-10 / D-040

Combination Air Valve BARAK

DT-040

Combination Air Valve With


Orifice Shut-off Valve Micro Barak

DT-040 LP

Combination Air Valve With


Orifice Shut-off Valve for Low Pressure

DG-70

Dynamic Combination Air Valve

D-021

Air & Vacuum Air Valve

Automatic Air Release Valve

S-021

Automatic Air Release Valve Reclaimed and Non-Potable Water

NR-010

Check Valve

NR-020

Check Valve

NR-030

Check Valve

Combination Air Valve Reclaimed and Non-potable Water

EnC-INDXAGR-11 7

A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice.
To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I. factory.
A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

RECOMMENDATIONS
Control and Effect of Air in Irrigation Systems
Air in an irrigation system must be controlled because the presence of air bubbles and air pockets, or their absence (vacuum), can cause problems and damage
to the system.

Problems and Damage Caused by the Presence of Air Pockets and Air Bubbles in Water Pipelines

1. Uneven flow through the pipe sometimes even stopping water flow altogether.
2. High losses of water head and consequently, energy losses.
3. Water hammer damage to the pipes, accessories and connectors.
4. False readings of water meters and automatic metering devices (and consequent payment for water not supplied, virtual use of water above licensed
pumping limits, under utilization of available water supplies, inadequate supply of water to crops because plants receive less water than the volume measured
by the hydrometer or water meter).
5. Inadequate supply of water to agricultural crops caused by throttling of flows and accumulated pressure losses at system ends.
6. Extensive damage to impeller systems in water meters, hydrometers, sprinklers and sprayers.
7. Corrosion damage.
8. Physical risk - when large volumes of air are released at high velocity.

The Problems Exacerbated by the Presence of a Vacuum

1. Mud and dirt are sucked into the system through drippers.
2. Seals, drippers and other accessories are sucked into the main distribution lines.
3. Uncontrolled entry of chemicals and fertilizers injected into agricultural and landscape irrigation systems.
4. Vacuum-induced collapse of pipes and accessories (sub-atmospheric pressures).
5. Increased risk of surge and slam conditions during the release of air pockets.
6. Cavitation damages..

Control of Air in Irrigation Systems Using A.R.I. Air Valves

There are three main types of air valves installed in irrigation systems: air & vacuum, automatic air release and combination (double) valves.
Air & Vacuum valves discharge large quantities of air from non-pressurized pipes and are used mainly when filling a line. These valves also make it possible
to admit large quantities of air when lines are drained and at water column separation. Air & Vacuum valves are also known as: kinetic valves; large orifice
air valves, vacuum breakers, low-pressure air valves and air-relief valves.
Automatic air release valves continuously release relatively small quantities of air from a pressurized line. The automatic air valve is also known as an: air
release valve; small orifice air valve and as a pressure air valve.
Combination air valves fulfill the tasks required of both types of valve air & vacuum and automatic. In other words they discharge or admit large
volumes of air when filling or emptying a system and continuously release small volumes air when the line is pressurized.
Combination air valves are also known as double orifice air valves.

The Range of Advanced Air Valves from A.R.I. Flow Control Accessories

A.R.I. is one of the worlds leading manufacturers of air valves. A.R.I. engineers have developed a range of advanced composite material air valves, specially
designed for use in agricultural and landscaping applications.
Technologically, the product range is based on the A.R.I. patented rolling seal mechanism, which replaces the old system that uses the valve float to seal air
valve orifices. The rolling seal mechanism and the aerodynamically designed float, in this line of air valves, provide much greater efficiency (larger orifices)
and have better resilience to withstand dynamic valve closure.
The new sealing mechanism enabled the development of small, lightweight air valves with a superior cost / benefit ratio. The width of the SG-10 automatic
air valve from A.R.I. is a mere 87 millimeters; it stands no more than 140 mm high and weighs just 330 grams. Despite its small dimensions, the area of air
orifice in this valve reaches 12 mm, which permits the release of 152 cubic meters of air per hour and can withstand pressures of up to 10 bar.
The valve's integral self-cleaning mechanism prevents blockages, leaks and particles from sticking to the sealing faces.
EnC-RCMAGR-11 13

The DG-10 model valve is just 180 mm wide, (including the protruding drainage funnel) 209 mm tall and weighs only 1.1 kg. With 12mm of automatic
orifice area and 804 mm of kinetic orifice area, intake and release of air is very efficient even more efficient than much larger and much heavier air valves,
which are overwhelmed and slam closed at lower differential pressures. The valve's integral self-cleaning mechanism prevents blockages and leaks and
particles do not stick to the sealing faces.

The R&D team at A.R.I has also developed the AV-010 air & vacuum valve to provide solutions for agricultural and landscaping irrigation systems. The
product is manufactured from composite materials and is available in 3, 2, 1 and 3/4 sizes. It is lightweight, compact and very competitively priced.

RECOMMENDATIONS
Calculating the Number of Valves Required for Installation
at Different Points in a System
Most irrigation systems on individual farms have relatively uncomplicated conditions and decisions can be based on the following table:
Model

Suitability

W. Pressure

Diameter

Air Volume m3/h

DT-040 Landscaping

10 Bar

1/2, 3/4

24

DG-10

Agriculture

10 Bar

3/4, 1

47

+ Landscaping

DG-10

Agriculture

10 Bar

215

+ Landscaping

AV-010

Agriculture

10 Bar

3/4, 1

160

+ Landscaping

AV-010

Agriculture

10 Bar

190

+ Landscaping

AV-010

Agriculture

10 Bar

390

To calculate the number of DG-10 (Barak) air valves required in an irrigation system, two criteria must be considered:
- The need to protect against vacuum damage (achieved by admitting air into the system)
- The need to discharge air from the system when it is filled with water
Air discharge requirements are usually lower than the air intake requirements for a line because the rates at which lines can be filled are generally
lower. Diagram Number 1 can be used to establish air discharge requirements during line filling. In Diagram Number 1, it can be seen that one
DG-10 valve is enough for pipes with a diameter of up to 8 (and sometimes up to 10).
This diagram is based on the release of air with a differential pressure of 0.4 bar.
The number of 2 DG-10 air valves required during the filling
of a line according to line filling rate (with a pressure differential
of 0.4 Bar) and pipe diameter.

Vacuum protection demands are usually higher, and this is particularly true when the line has acute angles of ascent and descent and / or when the
pipe has a large diameter. Diagram Number 2 is based on the Hazen Williams friction loss equation; a Hazen Williams coefficient of 110 and a
negative pressure differential of 0.4 bar.
The number of 2 DG-10 air valves required to protect against
vacuum damage during line drainage according to pipe diameter
and slopes of up to 15 (with a negative pressure differential
of 0.4 Bar)

The number of 2 DG-10 air valves required during the filling of


a line according to line filling rate (with a pressure differential of
0.4 Bar) and pipe diameter.

RECOMMENDATIONS
Critical Velocity Required for Transporting Air Bubbles
At the point where the rate of water flow drops below the critical velocity for air movement, air valves should be located at these critical points.
Installation of air valves is particularly important along long horizontal sections of line because flow rates are too low to carry air pockets and bubbles
to the downstream air valves. Installation of air valves is also important on long descending sections of pipe in which the flow of water must overcome
the opposing flow of air (flowing naturally to the high spots). See: Graphs describing critical speeds.

Calculating the Number of AV-010 Air & Vacuum Valves to be Installed in a Sub-surface Dripper
System
An AV-010 air & vacuum valve, used to prevent vacuum conditions as low as a negative pressure of 1 m, must be installed in every sub-surface drip
system to prevent suction of dirt into the drippers and subsequent blockages.
An AV-010 air & vacuum valve must also be used to prevent the formation of a vacuum in dripper system laterals and thereby prevent their collapse.
If the dripper-irrigated field is relatively flat and has no significant topographical changes, planning of air valve location will be based on the systems
working pressures and flow.
If the dripper-irrigated field contains substantial topographic changes, calculation of the AV-010 air & vacuum valve numbers and locations will be
based on the maximum drainage flow or on the flow of fluids during a burst the size of the pipe diameter, or the larger of the two

An Example of How to Evaluate The Size of Valves Required for Vacuum Prevention in a Dripper
System with a Negative Pressure of 0.1 Bar.
Sample: At a slope of up to 10%, when air supply must reach 300 m3/hr.

INSTALLATION GUIDE
Characteristics of Water Systems Used in
Agriculture and Landscaping:

SG-10-V
DG-70

- High frequency changes in flow characteristics.


- Water treatment in the field (filtration).
- Chemicals and fertilizers are injected into the irrigation system.
- Often necessary to use fragile and often complex equipment and
instrumentation.
- Large differences in the characteristics and materials used in pipes,
connectors and accessories.

Installation at Pumps

NR-040

DG-10 1

It is recommended to install a DG-70 dynamic air valve directly


after the pump and before the pumps check valve. Water pumped
from an independent supply such as a well, stream or reservoir
requires the intake of air into the pump and suction pipes. This air
will continue to disperse in the system during pump operation.
Mode of Operation: When the pump begins operating, large
volumes of air are discharged through the air & vacuum orifice of
the air valve. The water flow raises the float, closes the orifice and
opens the check valve. When the pump is shut down or ceases
to operate for any other reason, air, admitted through the air &
vacuum orifice, acts as a vacuum breaker. It protects the pump,
connectors, accessories and seals from damage caused by subatmospheric (negative) pressure.
The small automatic air release orifice continues to release air while
the pump is working and the line is pressurized. At its location
before the check valve, it protects the sealing face of the check valve
from cavitation damage caused by the presence of small air bubbles
in the water.
It is recommended to install a SG-10 air valve on the pump to
provide pump protection.
It is recommended to install a DG-70 air valve after the pump check
valve when the pipeline, upstream of this point, remains level or
drops below ground level. This air valve will allow for the intake
of air (at water column separation) when the pump is shut down
and the check valve closes. It also will discharge air when the water
column returns.

Installation in Locations with Changing


Pressures

DG-10 2

It is recommended to install a 1 DG-10 air valve in areas with


fluctuating pressure pressure regulation valves, pressure release
valves and at changes in pipe diameter. These are the areas where
air pockets form and might migrate into the line. As the pipe is
filled, these areas can become problematic if not provided with
an adequate air release system. If pressure fluctuations are not
too extreme, the SG-10 air valve will be sufficient when installed
downstream and close to these sensitive areas (close to an accessory
or disturbance).

EnC-INSTAGR-11

Installation at the Highest Points in a Line

It is recommended to install a DG-10 air valve at all the highest points


in each line where flow velocities drop below the critical velocity for
air movement (See: Graphs section below).
The air & vacuum component, installed at line high-points, discharges
air as the line is filled and admits air during line drainage, regardless
of whether the process is controlled or not (pipe burst or collapse).
The automatic air release component releases air accumulating at
high points when the line is pressurized during regular operations.
Where the topography is relatively flat, the line has shallow slopes
and the high points are relatively close, then the SG-10 automatic air
release valve can replace the DG-10 valves at some of the high points.

INSTALLATION GUIDE
DG-10 2

DG-10 2

DG-10 2

Installation on Long Lines

On long lines, it is recommended to install DG-10 or SG-10 valves


every 500 meters to 800 meters. It is also recommended to install
DG-10 valves on both sides of long sections of horizontal pipe.

Installation Close to a Main Line Valve

When the line is pressurized and an isolating valve is closed, it is


recommended to install an air valve before the isolating valve in order
to release air. Installation of the air valve will protect the valve plate
against cavitation damage caused by small air bubbles. During line
fill, if a valve at the end of the line is closed, slowing down the filling
process, it is recommended to install an air valve before the isolating
valve on lines with large diameters and high flow rates.
The installation of a DG-10 air valve after an isolating valve will also
protect the line from negative pressure (vacuum) conditions caused
when the valve is closed suddenly and assist in controlling the filling
process when the isolating valve is open.

Installation Where a Line Crosses Under a


Road or Ditch

It is recommended to install a DG-10 air valve wherever a large


diameter pipe, with sharp upward or downward angle changes,
crosses under a road or ditch. When the crossing point is wide and/or
deep, install the air valves at the uppermost point of the angle change
on both sides of the road. If the crossing point is short and shallow,
it is sometimes possible to install one DG-10 valve on the uppermost
point of angle change on the downstream side of the crossing point.

Installation Before Water Meters and


Automatic Regulators
DG-10 1

It is recommended to install a DG-10 air valve on the upstream side


of a flow meter and automatic flow regulator. Given that the water
flow regulator is a special type of isolating valve, it is recommended to
also install another DG-10 air valve on the downstream side after the
regulator.
Air can flow at velocities up to 29 times faster than water flow. The
fast-moving flow of air through a water meter or through the unit
that measures flow in the automatic regulator will spin the impeller,
used to measure flow, at very high velocities These instruments, which
cannot differentiate between water and air, will register very high flow
volumes that do not, in fact, exist. Another problem created under such
conditions is the inadequate supply of irrigation water to the fields
caused by these air-related inaccurately recorded high flow rates.
Water both cools and lubricates as it turns the impellers inside the
measuring equipment. Air moving through the measuring unit at
high speed causes the impeller to overheat and prevents water-cooling,
resulting in high temperature damage that can even melt the plastic
impeller. Installation of an air valve before the measuring equipment
will protect the meter from heat damage and false readings.

INSTALLATION GUIDE
Installation at the Main Line Control System

AV-010 2

It is recommended to install a combination DG-10 air valve directly


on the vertical pipe at the main line control system. This will ensure
control of air in the water supply and protection for the other
accessories in the control system and protection for the water meters
further downstream.
Install an AV-010 Guardian model air valve after the tap on the
lateral line feeding the dripper lines.

DG-10 2

Installation on Filters

It is recommended to install a DG-70 air valve on sand media filters


and a DG-70 air valve on screen and disc filters.
Filtering efficiency - air flowing through an automatic back flush
filter system disrupts the filters hydraulic functioning, creating
differential pressures in the filter. Consequently, the filter system
flushes frequently, wasting water and lowering system efficiency.

DG-70
NR-040

DG-10 2

NR-020

NR-020-FV

DG-10 1

Installation at Pipe Ends


AV-010 2

It is recommended to install a DG-10 air valve at the end of each line


before the main or sub-main valve.

DG-10 2
EnC-INSTAGR-11 15

INSTALLATION GUIDE
AV-010 1
D-040-C 1

DG-10 1

Installation on Drip Irrigation Supply Lines


and Laterals

It is recommended to install a DG-10 air valve directly on the vertical


pipe rising from the main line at the irrigation system head. On an
irrigation and dripper system, it is recommended to install an AV010 Guardian model air & vacuum valve after the sub-main valve.
If the lateral line is long, install a number of Guardian valves along
the line, with emphasis on the highest points in the field and along
the line. Guardian valves are required to prevent negative pressure
(vacuum) in the line which can cause the drippers to suck up mud
and dirt when flow stops.

AV-010 1

DG-10 2

DT-040

Installation in Irrigation or Landscaping


System Control Cabinet

It is recommended to install a DG-10/DT-040 valve (dependent on


the system flow rates) on the main line as it enters the control cabinet
and before the main valve (electrical or hydraulic valve).
It is recommended to install a SG-10 valve after the water meter and
the filter.
It is recommended to install a RP-500 Backflow Prevention Unit
with a diameter of 1 or 3/4" before an herbicide filter/fertigation
pump.

RP-500

A.R.I.

FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988

A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

DG-10
D-040

Agriculture

PN 10
PN 16

Combination Air Valve


Description

The D-040 series Combination Air Valve has the features of both an
air release valve and an air & vacuum valve.
The air release component is designed to automatically release small
pockets of air to the atmosphere as they accumulate at peaks or
along a pipeline or piping system when it is full and operating under
pressure.
The air & vacuum component is designed to automatically
discharge or admit large volumes of air during the filling or draining
of a pipeline or piping system. This valve will open to relieve
negative pressures whenever water column separation occurs.

Applications

- Pump stations: after the pump and after the check valve.
- On main lines and heads of systems.
- At the end of lines and at the end of a sub main
- On strainers and filters.

Operation

EnC-DG10AGR-11

The air & vacuum component, with the large orifice, discharges air
at high flow rates during the filling of the system and admits
air into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float, which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.

- Corrosion in pipes, fittings and accessories.


- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters into the valve and the float rises, pushing the rolling
seal back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: DG-10 0.1-10 bar. D-040 0.2-16 bar


- Testing pressure: DG-10 16 bar. D-040 25 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Reliable operation reduces water hammer incidents.
- Dynamic design allows for high velocity air discharge while
preventing premature closure.
- Lightweight, small dimensions, simple and reliable structure.
- The discharge outlet enables removal of excess fluids.
- The large size of the automatic air release orifice relative to the air
valve body:
Discharges air at high flow rates.
Lessens the danger of its obstruction by debris.
Enables the usage of the patented rolling seal mechanism, making
it less sensitive to pressure differential than a direct float seal.
- The body is made of high-strength composite materials and all
operating parts are made of specially selected, corrosion- resistant
materials.
- Due to its light weight, the valve may be installed on plastic piping
systems, as well as other lightweight piping systems.

DG-10 / D-040
Valve Selection

The air valve is available with:


- Wide size range: 1/2, 3/4, 1, 2 threaded male connections,
NPT or BSPT.
- Ball valve tap, BSPT or NPT male connection.
- The valve is available with a one-way check valve.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

D-040

D-040

DG-10

DG-10

DG-10 / D-040

DG-10 2

DG-10 1

D-040 2"

DIMENSIONS AND WEIGHTS


Nominal
Size

Dimensions mm

D-040 1"

Connection

Weight

1/2 3/4 1

100

143

3/8 BSP Female

183

215

1 BSP Female

Kg.

Orifice Area mm2


Auto.

A/V

0.33

7.8

100

1.10

12

804

2
3

4
5

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Body

Reinforced Nylon

2.

Discharge Outlet

Polypropylene

3.

1/2 3/4 1 Rolling Seal

E.P.D.M.

2 Rolling Seal Assembly:


3a. Screws

Stainless Steel SAE 304

3b. Plug Cover

Reinforced Nylon

3c. Rolling Seal

E.P.D.M.

3d. Plug

Reinforced Nylon

4.

Clamping Stem

Reinforced Nylon

5.

Float

Foamed Polypropylene

6.

O-Ring

BUNA-N

7.

Base

Reinforced Nylon
/ Brass ASTM B124

Optional Ball valve

4
5

/ St.St. SAE 316

Brass ASTM-B-124,

Nickel plated.

C
3c

3b

3a

3d

DT-040

Agriculture

PN 10

Combination Air Valve With Orifice Shut-off Valve Micro "Barak"


Description

The DT-040 Combination Air Valve is designed to prevent


disturbances caused by presence or absence of air in small water
supply systems.
The combination air valve combines an air & vacuum large orifice
and an automatic small orifice in one single body. It is the outcome
of development, based on many years of experience, resulting in the
production of this revolutionary valve.
The combination air valve discharges air during the filling of
the system and admits air while draining and at water column
separation.
It also releases accumulated air from the system while the system is
operating under pressure.

Applications

- Small filter systems.


- Green houses.
- Landscape.
- Small drip lateral manifold lines in agriculture.

Operation

EnC-DT040AGR-11

The air & vacuum component, with the large orifice, discharges air
at high flow rates during the filling of the system and admits
air into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float, which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.

- Corrosion in pipes, fittings and accessories.


- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters into the valve and the float rises, pushing the rolling
seal back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
and air release orifices.
2. Air will enter the system.

Main Features

- Working pressure range: 0.2-10 bar.


- Testing pressure: 16 bar.
- Working Temperature: 600 C.
- Dynamic design allows high velocity air discharge and preventing
premature closure.
- The large orifice with its self-cleaning mechanism dramatically
reduces obstruction due to debris.
- Integral orifice shut-off valve: an innovative built- in shut off valve
enables the closure of the air valve orifices with no interference with
water flow in the pipe.
- Discharge outlet: enables for the connection of a 10 mm
polyethylene discharge tube. 10mm polyethylene tube.
- The most compact air valve in the market.
- The air valve is made of corrosion- resistant composite materials.
- No maintenance.

Valve Selection

- Connections: Threaded 1/2", 3/4" BSPT / NPT


- Optional barbed and threaded connection for low pressure
systems: model DT-040 LP (max. working pressure 6 bar)
- One-way air flow option.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

DT-040

DIMENSIONS AND WEIGHTS


Model

imensions mm
D
A
B
C

Weight Orifice Area mm2


Gr.
Auto. A / V

1/2 (15 mm)

60

115

11

144

5.6

42

3/4 (20 mm)

60

115

11

144

5.6

42

1
2

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Cover & Shut Off Valve

Acetal

2.

Discharge Outlet

E.P.D.M.

3.

Flat Plug

Reinforced polypropylene

4.

Seat

BUNA-N

5.

O-Ring

E.P.D.M.

6.

Seal

Foamed polypropylene

7.

Float

Reinforced polypropylene

8.

Body

Nylon

3
4
5
6
7
8

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

DT-040 LP

Agriculture

PN 6

Micro "BARAK" for Low Pressure


Combination Air Valve With Orifice Shut-off Valve
Description

The DT-040 LP Combination Air Valve is designed to prevent


disturbances caused by presence or absence of air in small water
supply systems.
The combination air valve combines an air & vacuum large orifice
and an automatic small orifice in one single body. It is the outcome
of development, based on many years of experience, resulting in the
production of this revolutionary valve.
The combination air valve discharges air during the filling of
the system and admits air while draining and at water column
separation.
It also releases accumulated air from the system while the system is
operating under pressure.

Applications

Low pressure systems.

Operation

EnC-DT040LPAGR-11

The air & vacuum component, with the large orifice, discharges air
at high flow rates during the filling of the system and admits
air into the system at high flow rates during its drainage and at water
column separation.
High velocity air will not blow the float shut. Water will lift the
float, which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The air release component releases entrapped air in pressurized
systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of a high-energy burst of compressed air.
- Inaccuracies in flow metering.

As the system starts to fill, the valve functions according to the


following stages:
1. Entrapped air in the pipeline is discharged by the valve.
2. Liquid enters the valve, lifting the float which pushes the sealing
mechanism to its sealing position.
3. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
4. The float descends, unsealing the rolling seal. The air release
orifice opens and the accumulated air is released.
5. Liquid enters into the valve and the float rises, pushing the rolling
seal back to its sealing position.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The float will immediately drop down, opening the air & vacuum
and air release orifices.
2. Air will enter the system.

Main Features

-Working pressure range: 0.05 - 6 bar.


-Testing pressure: 10 bar.
-Working Temperature: 600 C.
-Materials: The air valve is made of corrosive-resistant composite
materials.
-2 IN 1 - two sets of orifices.
-Integral orifice shut-off valve: an innovative built- in shut off valve
enables the closure of the air valve orifices with no interference to
water flow in the pipe.
- The large orifice with its self-cleaning mechanism dramatically
reduces obstruction due to debris.
-Discharge outlet: enables for the connection of a 10mm
polyethylene discharge tube..
- Dynamic design allows high velocity air discharge and preventing
premature closure.
-Lightweight and small - 144 gr.
-The most compact air valve in the market.
-No maintenance.
-Seals at very low pressure.

Valve Selection

- Connections: Threaded 1/2", 3/4" BSPT / NPT.


- Optional model DT-040 (max. working pressure 10 bar)
- One-way air flow option.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

DT-040 LP

DIMENSIONS AND WEIGHTS


Model

imensions mm
D
A
B
C

Weight Orifice Area mm2


Gr.
Auto. A / V

1/2 (15 mm)

60

115

11

144

5.6

42

3/4 (20 mm)

60

115

11

144

5.6

42

1
2

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Cover & Shut Off Valve

Acetal

2.

Discharge Outlet

E.P.D.M.

3.

Flat Plug

Reinforced polypropylene

4.

Seat

BUNA-N

5.

O-Ring

E.P.D.M.

6.

Seal

Foamed Polypropylene

7.

Float

Reinforced Polypropylene

8.

Body

Nylon

3
4
5
6
7
8

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

DG-70

Agriculture

PN 10

Dynamic Combination Air Valve


Description

The DG-70 Dynamic Combination Air is a unique valve, operating


without a float and utilizing the rolling diaphragm principle. This
unique structure allows the dynamic air valve to discharge air
from the water system in a controlled and gradual manner, thus
preventing slam and local up-surges. When vacuum (down-surge)
occurs, the valve reacts quickly to admit large volumes of air into
the water system, thus impeding down-surges and, consequently,
all pressure surges in the line. The air & vacuum component of the
dynamic air valve is normally closed when the line is not operating,
thus preventing the infiltration of debris and insects into the water
system.

Applications

Recommended installations:
-Standard installation on water systems when the pipeline diameter
is 8 or greater.
-Installation on water systems for all pipeline diameters when the
slope of the pipeline is greater than 2%-3%.

Operation

When the system is charged and the pipeline begins to fill with
water, air flows in the pipeline and enters into the dynamic air valve,
raising the large orifice sealing assembly to the open position. Air is
then discharged, mainly out through the lower chamber large orifice
as well as small amounts of air released out through upper chamber
operating valve orifice. When the ensuing water enters the dynamic
air valve, it fills the lower chamber and some of it flows up through
the orifice chamber and enters into the upper operating chamber,
raising the float of the operating valve which rolls the sealing
mechanism to its sealed position. Pressure develops inside the upper
operating chamber, bringing about a controlled lowering and sealing
of the large orifice sealing assembly, which, in turn, closes the lower
chamber large orifice.

EnC-DG70AGR-11

NOTE: It is recommended to attach a drainage pipe to the


connection on the large orifice outlet as some water will be expelled
from the orifice during this closure stage. The size of the drainage
pipe should be, at a minimum, the diameter of the outlet and the
unattached end should remain open to the atmosphere.
At this stage, only the automatic air release component continues to
function and releases air through its small orifice. With a reduction
in line pressure, during drainage or shut-off, the pressure in the
valve is reduced and is lower then the outside atmospheric pressure.
The vacuum created will cause the large orifice sealing assembly
to rise up into its open position, opening the lower chamber large

PATENTED
orifice and allowing the intake of air from the atmosphere into the
system.

Main Features

- Working pressure: 0.2 - 10 bar.


- Testing pressure: 16 bar.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Valve body and interior components are made from composite
materials and are corrosion-resistant.
- Prevents slam and reduces water surges in the air valve and the
pipeline.
- Prevents the intrusion of debris and contaminants into the system.
- Valve is lightweight and small for easy installation; its operation
simple and reliable.
- Built-in connection at the outlet for surplus water drainage.
- Smooth and gradual closing unaffected by water flow.
- Extremely quiet closing.
- Automatic air release component releases large quantities of air
without becoming obstructed.

Valve Selection

- Valve sizes:
DG-70 2 - threaded BSPT/NPT male connections or flanged.
DG-70 M1 3 - threaded BSPT/NPT male connections or flanged.
DG-70 M2 4 - flanged.
- Flanges are made of composite materials in a wide range of
standards.
- The valve body is also available in Ductile Iron ASTM A-536-604018, in sizes 3, 4, 6, 8, 12 in a wide range of flange standards.
Optional:
- DG-70 I
One-way valve intakes air only,
without allowing air discharge.
- DG-70- T
Valve with flushing tap for the purpose of both
flushing the valve and the pipeline.
- Bug Screen
Attached to the valve outlet, prevents the
penetration of debris or insects into the air valve.
When ordering, please indicate the required model, dimensions,
working pressure and thread/flange standard.

DG-70
DIMENSIONS AND WEIGHTS
Nominal
Size

Dimensions mm

Connections

Weight

Kg.

DG-70 2 (50 mm) Threaded

144

216

2 BSP Male

3/8 BSP Female

DG-70 2 (50 mm) Flanged

165

224

2 BSP Male

DG-70 M1 3 (80 mm) Threaded

144

217

2 BSP Male

DG-70 M1 3 (80 mm) Flanged

200

228

DG-70 M2 4 (100 mm) Flanged

228

217

Orifice Area mm2


Auto.

A &V

1.040

7.8

1963

3/8 BSP Female

1.440

7.8

1963

3/8 BSP Female

1.075

7.8

1963

2 BSP Male

3/8 BSP Female

1.665

7.8

1963

2 BSP Male

3/8 BSP Female

1.860

7.8

1963

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Discharge Outlet

Polypropylene

2.

Operating Valve Body

Reinforced Nylon

3.

Rolling Seal

E.P.D.M.

4.

Operating Assembly

Foamed Polypropylene
+ St.St. SAE 304

3
4
5

5.

Clamping Stem

Reinforced Nylon

6.

O-Ring

BUNA-N

7.

Locking Ring

Reinforced Nylon

8.

Base Adaptor

Reinforced Nylon

9.

Supporting Ring

Reinforced Nylon

Rolling Diaphragm

Reinforced Nylon +

10

Sealing Assy.

E.D.P.M. + St.St. SAE 304

11

10.

8
9

+ Fabric
11.

Body

Reinforced Nylon

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

D-021

Reclaimed Water

PN 10

Combination Air Valve - Reclaimed and Non-Potable Water


Description

The D-021 Combination Air Valve combines an air & vacuum


orifice and an air release orifice in a single body. The valve is
specially designed to operate with liquids carrying solid particles
such as reclaimed water and effluents. The combination air valve
discharges air (gases) during the filling or charging of the system,
admits air into the system while it is being emptied of liquid and
releases accumulated air (gases) from the system while it is under
pressure and operating. The valves unique design enables the
separation of the liquid from the sealing mechanism and assures
optimum working conditions.

Applications

- Reclaimed water
- Raw water
- Effluent water
- Water with suspended solids
- Coolant water

Operation

EnC-D021AGR-11

The air & vacuum component discharges air at high flow rates
during the filling of the system and admits air into the system at
high flow rates during its drainage and at water column separation.
High velocity air will not blow the float shut. Water will lift the
float which seals the valve.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
The automatic air release component releases entrapped air in
pressurized systems.
Without air valves, pockets of accumulated air may cause the
following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.

- Danger of high-energy bursts of compressed air.


- Inaccuracies in flow metering.
As the system starts to fill, the combination wastewater valve
functions according to the following stages:
1. Entrapped air/gas is discharged by the valve.
2. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
3. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
4. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
5. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
6. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
7. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.
When internal pressure falls below atmospheric pressure
(negative pressure):
1. The floats will immediately drop down, opening the air &
vacuum and air release orifices.
2. Air enters into the system.

Main Features

- Working pressure range: 0.2 - 10 bar


Testing pressure: 16 bar
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Spring-loaded joint between the stem and the upper float:
vibrations of the lower float will not unseal the air release
component. Release of air will occur only after enough air
accumulates.

D-021
The Rolling Seal Mechanism: less sensitive to pressure
differentials than a direct float seal. It accomplishes this by having a
comparably large orifice for a wide pressure range (up to 10 bar).
Funnel-shaped lower body: designed to ensure that residue
reclaimed water solid matter will fall back into the system and be
carried away by the main pipe.
- Body made of composite materials, resistant to corrosion.
- Internal metal parts are made of corrosion-resistant stainless steel.
Floats are made of composite materials.
- Flexible rolling seal provides smooth positive opening, closing, and
leak-free sealing over a wide range of pressure differentials.
- Drainage tap with ball valve is provided.
- 3/8 threaded discharge outlet enables removal of excess fluids.
- Dynamic design allows for high velocity air discharge while

preventing premature closure.


- 1/4 ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- Size Range: 1& 2 with a BSP/NPT male threaded connection or


with flanged ends to meet any requested standard.
- Additional one-way out check valve attachment allows air
discharge, not allowing air intake.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

DIMENSIONS AND WEIGHTS


Dimensions mm
A

216

324

Connection

Weight

3/8 BSP Female

1.78

Kg.

Orifice Area mm2


Auto.

A/V

7.8

100

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M.

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Body

Reinforced Nylon

8. Float Stem

Stainless Steel SAE 316

9. Clamp

Reinforced Nylon

+ Stainless Steel SAE 316

10. O-Ring

BUNA-N

11. Float

Foamed Polypropylene

12. Base

Reinforced Nylon

13. Ball Valve 1/4

Brass, Nickel Plated

1
2
3
4
5
6
7
8
9
10
11
12
13

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

AV-010

Agriculture

PN 10

Air & Vacuum Air Valve


Description

The AV-010 Air & Vacuum Valve discharges air at high flow rates
during the filling of the system and admits air at high flow rates
during drainage , pump shut-off or at water column separation.

Applications

Agricultural and landscape irrigation laterals.

Operation

The air & vacuum valve discharges air at high flow rates during
the filling of the system and admits air at high flow rates during
drainage, pump shut-off or at water column separation.
High velocity air will not blow the float shut. Water entry will lift
the float which seals the valve.
The smooth discharge of air reduces pressure surges and other
destructive phenomena.
At any time during system operation, should internal pressure of the
system fall below atmospheric pressure, air will enter the system.
The intake of air in response to negative pressure protects the system
from destructive vacuum conditions and prevents damage caused
by water column separation. Air entry is essential to efficiently drain
the system.
As the system starts to fill, the valve functions according to the
following stages:
1. Entrapped air is released by the valve.
2. Water enters the valve, lifting the float and sealing the valve.
When internal pressure falls below atmospheric pressure
(negative pressure):
The float will immediately drop down, opening the air & vacuum
orifice.
Air will enter the system.

Main Features

- Working pressure range: 0.2 - 10 bar


- Testing pressure: 16 bar
- Working Temperature : 600 C
- Maximum intermittent temperature : 900 C
- The body is made of high strength composite materials, and all
operating parts are made of specially selected corrosion-resistant
materials.
- Drip-tight sealing at low pressure.
- All parts are UV protected.
- Lightweight, small dimensions, simple and reliable structure.

Valve Selection

- Available in 3/4 (20mm), 1 (25mm) male threaded, 2 (50mm),


3 (80mm) female threaded NPT/BSPT.
- Optional addition: Shrader valve for measuring local line pressure
(3/4", 1" only).

Upon ordering, please specify: model, size, working pressure,


threads standard and type of liquid

EnC-DG10AGR-11

AV-010
DIMENSIONS AND WEIGHTS
Nominal
Size

Dim. mm
Weight Orifice Area
A B Kg. mm2

3/4 (20mm)

60

124

0.1

314

1 (25mm)

60

124

0.1

314

2 (50mm)

73

122

0.2

800

3 (80mm)

104

165

0.6

2000

3/4" 1"

PARTS LIST AND SPECIFICATION


No. Part

3/4 , 1

Material
2

1.

Cover

Polypropylene

Polypropylene

Polypropylene

2.

Seal

BUNA-N

E.P.D.M.

E.P.D.M.

3.

Float

Polypropylene

Reinforced Nylon

Reinforced Nylon

4.

Body

Polypropylene

Reinforced Nylon

Reinforced Nylon

5.

Disc

Reinforced Nylon

Reinforced Nylon

2"

B
4

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

SG-10
S-050

Agriculture

PN 10

PN 16

Automatic Air Release Valve


Description

The S-050 series Automatic Air Release Valve releases accumulated


air from the system while it is under pressure. The presence of air
in a water system can reduce the effective cross sectional flow area
resulting in increased head loss and decreased flow. Unwanted air
may also cause water hammer and metering inaccuracies, while
hastening corrosion.
In spite of its compact and light weight structure, the S-050 series
Automatic Air Release Valve has a 12mm orifice that enables it to
release air at high flow rates and is not exposed to obstruction by
debris.

Applications

- On most types of pumps.


- After filters, pressure reducers and fertilizer injection systems.

Operation

The automatic air release valve releases entrapped air from


pressurized systems.
Without air valves, pockets of accumulated and entrained air
may cause the following hydraulic disturbances:
- Restriction of effective flow due to a throttling effect as would a
partially closed valve. In extreme cases this will cause complete flow
stoppage.
- Obstruction of efficient hydraulic transmission due to air flow
disturbances.
- Accelerate cavitation damages.
- Pressure transients and surges.
- Corrosion in pipes, fittings and accessories.
- Danger of high-energy bursts of compressed air.
- Inaccuracies in flow metering.

EnC-SG10AGR-11

The valve functions while the system is under pressure,


according to the following stages:
1. Entrapped air, which accumulates at peaks and along the system,
rises to the top of the valve, which in turn displaces the liquid in the
valves body.
2. The float descends, unsealing the rolling seal. The automatic air
release orifice opens and the accumulated air is released.
3. Liquid enters the valve and the float rises, pushing the rolling seal
back to its sealing position.
Note: Automatic air release valves are designed to release air as it
accumulates at peaks in pressurized systems. They are not normally
recommended for vacuum protection or for discharging large
volumes of air, because of their inherently small orifices. For this

purpose, air & vacuum valves are recommended as they have much
larger orifices.
However, automatic air release valves will permit air to enter the
system under vacuum conditions. If this is not desirable, specify the
one-way out check valve.

Main Features

- Working pressure range: SG-10 0.1 - 10 bar



S-050 0.2 - 16 bar
- Test pressure for the air valve is 1.5 times its working pressure.
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- The body is made of high strength composite materials and all
operating parts are made of specially selected corrosion- resistant
materials.
- The larger than usual orifice enables it to release air at higher flow
rates than other automatic air release valves of its kind.
- The large orifice with its self-cleaning mechanism dramatically
reduces
obstruction due to debris.
- The valves rolling seal mechanism design is less sensitive to
different pressures than a direct float seal, thus enabling a one size
orifice for a wide pressure range (from 0.2 up to 10/16 bar).
- Light weight, simple and reliable structure.
- A drainage outlet enables removal of excess fluids.

Valve Selection

- Available in male threaded sizes: 1/2, 3/4, 1 - BSP / NPT


- One-way out check valve - available as a valve that will only release
air from the system and will not admit air to the system when
negative
pressure conditions occur. This characteristic is obtained by adding a
check valve to the air outlet.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

SG-10 / S-050

DIMENSIONS AND WEIGHTS


Dimensions mm
A

100

140

Connection

Weight

Orifice Area

1/8 BSP Female

0.3

12

Kg.

mm2

SG-10

S-050

A
1

PARTS LIST AND SPECIFICATION

No.

Part

Material

1.

Body

Reinforced Nylon

2.

Discharge Outlet

Polypropylene

3.

Rolling Seal

E.P.D.M.

4.

Clamping Stem

Reinforced Nylon

5.

Float

Foamed Polypropylene

6.

O-Ring

BUNA-N

7.

Base

Reinforced Nylon / Brass ASTM B-124

8.

Strainer

Nylon

3
4

5
6
7
8

S-050

SG-10

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

S-021

Reclaimed Water

PN 10

Automatic Air Release Valve


for Reclaimed and Non-Potable Water
Description

The S-021 Automatic Air Release Valve is specially designed to


operate with liquids carrying solid particles.
The automatic air release valve releases accumulated air from the
system while it is under pressure.
The valves unique design enables the separation of the liquid from
the sealing mechanism and assures optimum working conditions.
The presence of air in a reclaimed and non-potable water system can
reduce the effective cross sectional flow area, resulting in increased
head loss and decreased flow.
Unwanted air may also cause water hammer and metering
inaccuracies, while hastening corrosion.

Applications

- Reclaimed water
- Raw water
- Effluent water
- Water with suspended solids
- Coolant water

Operation

EnC-S021AGR-11

The S-021 is an air release valve for reclaimed and non-potable


water systems.
As the system starts to fill, the automatic air release valve
functions according to the following stages:
1. When the liquid level reaches the valves lower portion, the lower
float is lifted, pushing the sealing mechanism to its sealing position.
2. The entrapped air is confined in a pocket between the liquid
and the sealing mechanism. The air pressure is equal to the system
pressure.
3. Increases in system pressure compress the trapped air in the upper
section of the conical chamber. The conical shape assures the height
of the air gap. This enables separation of the liquid from the sealing
mechanism.
4. Entrapped air (gas), accumulating at peaks and along the system,
rises to the top of the valve, and displaces the liquid in the valves
body.
5. When the liquid level is lowered to a point where the float is no
longer buoyant, the float drops, unsealing the rolling seal. The air
release orifice opens and allows part of the air that accumulated in
the upper portion of the valve to be released to the atmosphere.
6. Liquid enters the valve. The float rises, pushing the rolling seal to
its sealing position. The remaining air gap prevents the wastewater
from fouling the mechanism.

Note: the automatic air valves are specifically designed to release


air as it accumulates at the high points of a pressurized, operating
system. Because of their inherently small orifice size, they are not
recommended for vacuum protection or for discharging large
quantities of air or gas, although they will admit some air into the
system under vacuum conditions.

Main Features

- Working pressure range: 0.2 - 10 bar


- Testing pressure: 16 bar
- Maximum working temperature: 60 C.
- Maximum intermittent temperature: 90 C.
- Body made of composite plastic material, resistant to corrosion.
- Internal metal parts are made of corrosion-resistant stainless steel.
- Floats are made of composite materials.
- Flexible rolling seal provides smooth positive opening, closing, and
leak-free sealing over a wide range of pressure differentials.
- 1/8 threaded discharge outlet enables removal of excess fluids.
- Drainage tap with ball valve is provided.
- The unique design of the valve prevents contact between the
wastewater and the sealing mechanism by creating an air gap at the
top of the valve. These features are achieved by:
The conical body shape: designed to maintain the maximum
distance between the liquid and the sealing mechanism and still
obtain minimum body length.
Funnel-shaped lower body: designed to ensure that residue
wastewater matter will fall back into the system and be carried away
by the main pipe.
Rolling Seal: provides smooth positive opening, closing, and leakfree sealing over a wide range of pressure differentials.
- 1/4 ball valve releases trapped pressure and drains the valve body
prior to maintenance.

Valve Selection

- Size Range: 1& 2, BSP or NPT male threaded connection or


flanged to meet any requested standard.
- Flanges are manufactured of composite materials.
- Additional one-way out check valve attachment allows air
discharge, not allowing air intake.
- For best suitability, it is recommended to send the fluid chemical
properties along with the valve request.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

S-021
DIMENSIONS AND WEIGHTS
Nominal

Size

Dimensions mm

Connection

Weight

Orifice Area

324

1/8 BSP Female

1.78

12

324

1/8 BSP Female

1.78

12

1 (50mm)

216

2 (80mm)

216

Kg.

mm2

PARTS LIST AND SPECIFICATION


No. Part

Material

1. Body

Reinforced Nylon

2. Discharge Outlet

Polypropylene

3. Rolling Seal

E.P.D.M.

4. Clamping Stem

Reinforced Nylon

5. Float

Foamed Polypropylene

6. O-Ring

BUNA-N

7. Body

Reinforced Nylon

8. Float Stem

Stainless Steel SAE 316

9. Clamp

Reinforced Nylon

+ Stainless Steel SAE 316

10. O-Ring

BUNA-N

11. Float

Foamed Polypropylene

12. Base

Reinforced Nylon

13. Ball Valve 1/4

Brass, Nickel Plated

2
3
4
5
6
7

8
9
10
11
12
13

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

NR-010

Agriculture

PN 10

Wafer Style Check Valve


Description

The NR-010 Check Valve is compatible for installation in horizontal


pumps or boosters for landscape and agriculture. The check valve
prevents the return flow of water to its source and provides quiet
closing and total sealing of the sealing face.
The check valve is designed for free flow of water without interference
and with minimal head loss.
The check valve is made from composite materials to withstand highly
abrasive conditions and to ensure long-term service in corrosive liquid
environments such as seawater, brine and chlorine water.

Applications

After pumps/boosters.
Foot check valve for pumping from ponds.
Filtration systems.
Swimming pools.
Fertilizer systems.

Main Features

Working pressures: Up to 10 bar.


The body of the valve is made from composite materials.
The valve connects between flanges.
The valve is supplied together with seals for flanges.
The spring assembly mechanism is outside of the flow cross-section
and can be replaced without removing the valve from the line.
Maximum working temperature: 60 C.

Valve Selection

The NR-10 is available in diameter sizes 3", 4".


The valve is available with a reed switch that transmits a contact
signal upon the start of flow or its discontinuance (pump safety
mechanism), Model NR-010-LS.
The valve is also available for pressures of up to 16 bar,
Model NR-020.
EnC-NR010AGR-11

Upon ordering, please specify: model, size, working pressure,


threads standard and type of liquid.

NR-010 LS

NR-010
DIMENSIONS AND WEIGHTS
Nominal

Dimensions mm

Weight

Size

NR -010 3

75

172

132

571

Gr.

NR -010 LS 3

75

219

132

580

NR-010 4

85

191

151

732

NR-010 LS 4

85

238

151

740

PARTS LIST AND SPECIFICATION


No.

Part

Material

1.

Body

Reinforced Nylon

2.

Disc

Reinforced Nylon

3.

Seal

E.P.D.M.

4.

Bolt (x2)

Stainless Steel SAE 304

5.

Shaft

Stainless Steel SAE 316

6.

Shaft Housing

Acetal

7.

Spring Housing

Acetal

8.

Spring Cover

Reinforced Nylon

9.

O-Ring

BUNA-N

10.

Spring

Stainless Steel SAE 302

11.

Directional Arrow

Polypropylene

12.

Flange Seals

E.P.D.M.

13.

Magnet Cover

Reinforced Nylon

14.

Magnet (x3)

15.

Magnet Shaft

16.

Dry Reed Limit Switch

13
14
15
16

Acetal

8
6

10

12

12

11

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

NR-020

Agriculture

PN 16

Wafer Style Check Valve


Description

Options

The NR-020 Check Valve is compatible for installation on


horizontal pumps and boosters in landscape and agriculture. The
check valve prevents the return flow of water to its source and
provides quiet closing and total sealing of the sealing face. The
check valve is designed for free flow of water without interference
and minimal head loss. The check valve is made from composite
materials (diameters of 3-6) and an anodized aluminum alloy (8
diameter) .

The valve is available in diameters: 3, 4, 6, 8.


The valve is available with a limit switch that transmits a contact
signal at flow start or its discontinuance (pump safety mechanism),
Model NR-020-LS.
The valve is available with a strainer added as Check Valve,
Model NR-020-FV (foot valve).
The valve is also available for pressures of up to 10 bar,
Model NR-010.

Applications

For maximum compatibility, it is recommended to specify the


composition of the liquids and requirements of the system.
For check valve selection and placement, use the recommendation
page or contact our customer service department.

After pumps/boosters.
Foot check valve for pumping from ponds.
Filtration systems.
Swimming pools (for 8" models, additional modifications are
required for this application).
Fertilizer systems.

Main Features

EnC-NR020AGR-11 37

Working pressures: up to 16 bar.


Maximum working temperature: 60C.
Maximum intermittent temperature: 90 C.
In the 3-6 diameter models, the valve body and disc are made
from composite materials which are resistant to highly abrasive
conditions and durable in environments using corrosive liquids such
as sea water, brine and chlorine.
In the 8" diameter models, the valve is made from an anodized
aluminum alloy. Use in corrosive liquid environments such as sea
water, brine and chlorine, require an additional modification to the
check valve and needs to be specified.
Metal parts are made from SAE 304 stainless steel (SAE 316
stainless steel is also available upon request).
The valve is supplied together with seals for flange to flange
installation.
The spring assembly mechanism is outside of the flow cross-section
and can be replaced without removing the valve from the line.

Upon ordering, please specify: model, size, working pressure,


threads standard and type of liquid.

NR-020

NR-020

NR-020 3-6
PARTS LIST AND SPECIFICATION

1
2

No. Part

Material

1.

Spring Chamber

Reinforced Nylon

2.

Spring

Stainless Steel SAE 302

3. O-Ring

BUNA-N

4.

Spring Seat

Acetal

5.

Indicator Stem Bushing Teflon

6.

Flap Shaft

Stainless Steel SAE 316

7.

Roller Shaft

Stainless Steel SAE 316

8.

Roller

Reinforced Nylon

9.

Flap

Reinforced Nylon

10.

Flap Seal

E.P.D.M.

8
9
10

11

11. Cover Bolts

Stainless Steel SAE 304

12. Disc

Stainless Steel SAE 304

13. Bolts

Stainless Steel SAE 304

14.

Cover Seal

E.P.D.M.

14

15.

Body

Reinforced Nylon

16.

Cover

Reinforced Nylon

15

17. Flange Seals

12
13

16

E.P.D.M.

17

NR-020 8
PARTS LIST AND SPECIFICATION
No. Part

Material

1.

Spring Chamber

Reinforced Nylon

2.

Spring

Stainless Steel SAE 302

3. O-Ring

BUNA-N

4.

Acetal

Spring Seat

1
2
3
4
5
6

C
B

5. Plug

Brass

6. O-Ring

BUNA-N

7.

Roller

Reinforced Nylon

8.

Shaft

Stainless Steel SAE 304

9.

Flap Shaft

Stainless Steel SAE 303

10

10. Flap

Aluminum

11.

O-Ring

BUNA-N

11

12.

Body

Aluminum

8
9

12

NR-020

NR-020 LS

NR-020 LS 3-6 WITH LIMIT SWITCH


PARTS LIST AND SPECIFICATION
No. Part

1
2
3

Material

1.

Limit Switch

2.

Plastic Cover

Reinforced Nylon

3.

O-Ring

E.P.D.M.

4.

Indicator Stem Bushing Teflon

5.

Nut

Reinforced Nylon

6.

Spring Chamber

Reinforced Nylon

7.

Spring

Stainless Steel SAE 302

8.

Position Indicator Stem Stainless Steel SAE 316

9.

O-Ring

4
5
6
7
8
9
10
11
12

BUNA-N

13

10. Spring Seat

Acetal

11. Shaft Bushing

Stainless Steel SAE 303

12. Shaft

Stainless Steel SAE 316

15

13. Flap Shaft

Stainless Steel SAE 316

16

14. Roller

Reinforced Nylon

15. Flap

Reinforced Nylon

17

16. Flap Seal

E.P.D.M.

17. Cover Bolts

Stainless Steel SAE 304

18. Disc

Stainless Steel SAE 304

19. Disc Bolts

Stainless Steel SAE 304

20. Cover Seal

E.P.D.M.

21. Body

Reinforced Nylon

22. Cover

Reinforced Nylon

23. Flange Seals

E.P.D.M.

14

18
19
20
21
22
23

A
EnC-NR020AGR-11 39

NR-020

NR-020 FV

DIMENSIONS AND WEIGHTS


Nominal

Dimensions mm

Weight Kg.

Size

NR-020

NR-020 LS

NR-020FV

3 (50 mm)

85

148

204

286

207

1.15

1.5

1.5

4 (80 mm)

93

165

214

296

230

1.6

2.0

2.0

6 (80 mm)

115

228

311

393

296

3.15

3.6

4.0

8 (80 mm)

127

273

342

428

339

6.5

6.9

7.2

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

NR-030

Agriculture

PN 16

Check Valve
Description

The NR-030 Swing-Type Non-Return Valve allows for onedirectional flow and prevents the return flow of the liquid to its
source.
This check valve is designed for installation on horizontal pumps,
boosters and filtration systems, preventing return flow and providing
for quiet closure and total sealing of the sealing face.
The length of the NR-030 check valve is designed to allow
installation between two flanges of short spacing, allowing for
installation of the check valve in small and narrow systems.

Applications

- Potable water systems


- Reservoirs
- Pumps and pump stations
- Lateral pivots
- Swimming pools
- Filtration systems

Specifications

The NR-030 check valve is available in the following sizes:


2" 16" with the extended shaft
2" 8" with the short shaft
Working pressure: 16 bar (250 psi)
Maximum working temperature: 90C.
FBE coating according to the standard DIN 30677-2
Surge-resistant cast iron body.
Cast steel St.37 disc with natural rubber flap seal, allowing for sealing
at low pressures.
Internal parts made of bronze and/or stainless steel.
- NR-030 check valve can be installed either horizontally or vertically
(only when the flow is in an upward direction).

Selection
EnC-NR030AGR-11

- Counterweights can be installed for quiet closure.


- A limit switch can be installed to alert and protect the pump during
the start of water flow and its cessation.
- An extended shaft can be installed, enabling the addition of a
counterweight and/or limit switch.
- For maximum suitability, it is recommended to define the fluid
composition and requirements of the system.
Upon ordering, please specify: model, size, working pressure,
threads standard and type of liquid.

Limit Switch Model LS


A device which transmits a contact signal to the control panel,
monitors the flow status of the non-return valve, and provides for a
smooth and trouble-free operation of the system.
The device is made up of a stationary part, fastened to the body of
the non-return valve and a single moving part, fastened to the shaft
of the valve, which moves with the opening/ closing of the nonreturn valve.
The limit switch for the non-return valve can be obtained in
diameters 2- to 16.
LS-010 Model 2-4
LS-015 Model 6-16

Instructions for Installation and Usage

The base (5) of the limit switch and the limit switch itself (6) should
be installed on the brass plug (2) of the non-return valve, being
firmly fastened there by the bolt (1) located on the side of the base.
The activator (3) should be installed on the shaft of the non-return
valve, with the straight part pointing at the limit switch gate pulley.
The activator can be adjusted in such a way that it activates the limit
switch according to the desired opening / closing angle of the nonreturn valve. Once it is properly set, the activator is fastened to the
shaft with the fastening bolt (4).

NR-030
PARTS LIST AND SPECIFICATION
No.

Part

Material

1.

Body

Cast Iron ASTM A48 CL.35B

2.

Key

Stainless Steel SAE 304

3.

Arm

4.

Pin

Stainless Steel SAE 303

5.

Flap 3- 4

Stainless Steel ASTM A 744 CF8

6- 16

Bronze ASTM B62 B271 C83600

6.

Flap Seal

Natural Rubber

7.

Rollpin

8.

Disc

3- 4

Stainless Steel ASTM A 744 CF8

6- 16

Bronze ASTM B62 B271 C83600

Stainless Steel SAE 304


3- 4
6- 16

Stainless Steel ASTM A 744 CF8

9.

Slotted Nut

Stainless Steel SAE 304

10.

Sealing Ring

Bronze ASTM B62 B271 C83600

11.

Counterweight

Cast Steel

12.

Shaft

Stainless Steel SAE 303

13.

O-Ring

BUNA-N

14.

Plug

Brass ASTM B124

15.

Seal
Washer -16 only

DIMENSIONS AND WEIGHTS

Steel ST.37

Nominal

Size

Dimensions mm
B

Weight
Kg.

3 (80mm)

156

202

255

250

11.6

4 (100mm)

176

253

290

300

14.1

6 (150mm)

223

332

405

400

29.5

Fiber

8 (200mm)

250

409

480

500

44.0

10 (250mm)

266

468

570

600

64.0

Stainless Steel SAE 303

12 (300mm)

304

531

650

650

85.5

16 (350mm)

388

619

700

168.0

11
12
1

13

14

15

6
7
8
9
10

A.R.I. FLOW CONTROL ACCESSORIES Ltd. www.arivalves.com ari@ari.co.il Tel: 972-4-6761988


A.R.I. FLOW CONTROL ACCESSORIES Ltd. reserves the right to make productchanges without prior notice. To insure receivingupdated information on parts specifications, please call the export dept. atthe A.R.I.
factory. A.R.I. FLOW CONTROL ACCESSORIES Ltd. shall not be held liable for any errors. All rights reserved.

Vous aimerez peut-être aussi