Académique Documents
Professionnel Documents
Culture Documents
Slide 25
Oscilloquartz 2007
Installation Checklist
Unpacking
Rack mounting
Local/Remote connections
Cabling communication ports
Slide 26
Oscilloquartz 2007
Unpacking
Check first that the packing does not have any
signs of rough handling such as dents or
scratches, which might have occurred during
transportation
Should the equipment have suffered any
damage, immediately notify the carrier and
retain the packing material for inspection
Save the packing material for use in case of
return shipment
Compare the OSA 5548C SSU contents with
Slide 27
Oscilloquartz 2007
Handle in
new position
Handle
Handle
screws
Fixation
screws
Shelf
Rear
Slide 28
Ear
Oscilloquartz 2007
Slide 29
Oscilloquartz 2007
Slide 30
Oscilloquartz 2007
POWER A
POWER
GROUND (GND)
OSCILLOQUARTZ
Slide 31
Oscilloquartz 2007
Input Connections
Choose a connector among these 8
We recommend using 1 connector per range, either
E1 or FREQ
Connect the frequency inputs to the Freq. BNC
connector with a 50 or 75 ohms asymmetrical
coaxial cable
Connect the E1 input either directly to the BNC
connector for the asymmetrical 75 ohms option or
through a 120/75 ohms adapter (Balun) for the
symmetrical 120 ohms option.
Connect the GPS Antenna Cable if any. Ensure
that the Antenna is correctly protected before.
Slide 32
Oscilloquartz 2007
Mounting Principle
Slide 33
Oscilloquartz 2007
Slide 34
Oscilloquartz 2007
Slide 35
Oscilloquartz 2007
Output Tiles
Two Groups of 10 Ports are
supplied on each Tile.
Each group can be
configured either with
2.048MHz or E1
Slide 36
Oscilloquartz 2007
Slide 37
Oscilloquartz 2007
Slide 38
Oscilloquartz 2007
Dry Contact
+3V3
ALARM 1
ALARM
DETECTION
HCMOS
GND
REMOTE UNIT
Slide 39
Oscilloquartz 2007
LAMP
NO
Slide 40
Oscilloquartz 2007
Slide 41
Oscilloquartz 2007
Maintenance
The OSA 5548C SSU does not require
any routine maintenance!
In order to ensure correct functioning
of the LEDS and the cards operating in
stand-by mode, a regular preventive
maintenance is recommended. For
that purpose do the following:
LAMP TEST
Switch Cards (INC, THC, GPS)
Slide 42
Oscilloquartz 2007
Card Troubleshooting
Check the STATUS LED:
LOCATING TEETH
DIN CONNECTOR
RED:
the card is faulty (some
exceptions for THC)
SERIAL NUMBER
OFF:
check the cards fuse
RED Flashing:
STATUS
ORANGE:
Slide 43
Text
OUT 1-10
DS1
FUSE
CC
CARD ABBREVIATION
& PART NUMBER
BAIL HANDLE
FRONT PANEL
OUT 11-20
DS1
CC
A0xxxx
LOCKING SCREWS
OUC
OSCILLOQUARTZ
Oscilloquartz 2007
INC Troubleshooting
IN LEDs:
GREEN Flashing:
The Input Line is in Wait-To-Restore time
ORANGE Solid:
The line is being in MONITORING mode
RED Solid:
The input signal is rejected or disqualified by
RED Flashing:
The input is rejected due to a performance
alarm
OFF:
Input Line unused, disabled or INC in stand-by
Slide 44
Oscilloquartz 2007
GPS Troubleshooting
GPS LED
RED Solid:
No or not enough GPS signal available. PPS input reference not
available.
RED Flashing:
No connection to GPS Antenna. Either shorted or opened GPS
antenna cable. When both GPS and OCXO LEDs have this status, the
input is rejected due to a performance alarm.
Yellow:
The GPS input is OK but currently monitored
OFF:
The GPS input is disabled or the GPS Card is in Stand-by
OCXO LED:
RED Solid:
Internal GPSs OCXO failure or Initialisation phase
RED Flashing:
GPS pre-tracking sequence.
When both GPS and OCXO LEDs have this status, the input is
rejected due to a performance alarm.
OFF:
When the GPS LED is GREEN solid, the GPS card delivers signal to
the THC. Or the GPS card is in stand-by when the GPS LED.
Slide 45
Oscilloquartz 2007
THC Troubleshooting
HOLDOVER LED
RED Solid:
Holdover/Freerun
RED Flashing:
Fast Start-up
OSCILLATOR LED:
RED Solid:
Oscillator failure
RED Flashing:
Oscillator in Warm-up
Slide 46
Oscilloquartz 2007
SGC Troubleshooting
E1 LED
GREEN Flashing:
Pass-through mode
RED Solid:
E1 generation failure
RED Flashing:
No clock signal received by the SGC
f LED
GREEN Flashing:
Pass-through mode
RED Solid:
Frequency and/or PPS generation failure
RED Flashing:
No clock signal received by the SGC
Slide 47
Oscilloquartz 2007
OUC Troubleshooting
OUT E1 LEDs
RED Solid:
No E1 distribution to Output ports
RED Flashing:
No clock signal received by the OUC
OFF:
outputs are not configured to supply E1 clock to
Output ports
OUT f LEDs
RED Solid:
No 2.048 MHz distribution to Output ports
RED Flashing:
No clock signal received by the OUC
OFF:
The outputs are not configured to supply 2.048 MHz
clock to Output ports
Slide 48
Oscilloquartz 2007
MAC Troubleshooting
MST LED
GREEN Solid:
Indicates that it is a MASTER shelf
RMT LED
This LED is unused in the OSA 5548C SSU version
EXP LED
GREEN Solid:
Indicates that it is an EXPANSION shelf
USC LED
YELLOW Solid:
Indicates that at least one user is logged
Slide 49
Oscilloquartz 2007
Card Replacement
A new card inserted is automatically configured by
configured
CAUTION
When handling the OSA 5548C SSU unit or spare cards, use a
grounded wrist strap to avoid ESD (Electro Static Discharge)
Avoid touching components or connectors
Avoid placing the card on an ungrounded surface
Avoid placing the card on or near insulated elements and/or surfaces
Slide 50
Oscilloquartz 2007
Slide 134
Oscilloquartz 2007