DG12-100

Specification

(12V100Ah)

DG (Deep Cycle GEL,12 Volts ) series is pure GEL battery with 12 years
floating design life , it is ideal for standby or frequent cyclic discharge
applications under extreme environments. By using strong grids, high
purity lead and patented Gel electrolyte, the DG series offers excellent
recovery after deep discharge under frequent cyclic discharge use, and
can deliver 400 cycles at 100% DOD. Suitable for solar, CATV, marine , RV
and deep discharge UPS, communication , and telecommunication , etc.

Cells Per Unit

Voltage Per Unit

12

Capacity

100Ah@20hr-rate to 1.75V per cell @25 C

Weight

Approx. 30.0 Kg ( Tolerance2%)

Max. Discharge Current

1000 A (5 sec)

Internal Resistance

Approx. 7.5 m

Operating Temperature Range

Discharge: -40 C~60 C


o
Charge:-20 oC~50 C
o
o
Storage: -40 C~60 C

Normal Operating Temperature Range

25 C5 oC

Float charging Voltage

13.6 to 13.8 VDC/unit Average at 25 C

Recommended Maximum Charging


Current

20A

Equalization and Cycle Service

14.2 to 14.4VDC/unit Average at 25 C

Self Discharge

RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored


for more than 6 months at 25oC. Self-discharge ratio less than 3%
per month at 25oC. Please charge batteries before using.

Terminal

Terminal F5/F12

Container Material

A.B.S. UL94-HB, UL94-V0 Optional.

Dimensions
Terminal F12

Dimension: 328(L)172(W)222(H)

Unit: mm

37

Terminal F5

Constant Current Discharge Characteristics: A (25 C)(The capacity reaches the peak value after 5-20 cycles.)
F.V/Time
9.60V
10.0V
10.2V
10.5V
10.8V
11.1V

5MIN
248.9
241.7
234.5
213.1
194.5
168.0

10MIN 15MIN
185.4 145.0
176.4 142.1
170.1 139.8
158.9 134.7
146.6 125.6
132.5 114.0

30MIN
95.38
93.80
93.50
93.00
92.50
87.39

1HR
58.30
58.03
57.49
56.96
55.02
52.27

2HR
35.10
34.84
34.57
34.31
33.69
32.20

3HR
25.39
25.30
25.10
25.00
24.32
23.25

4HR
20.27
20.18
20.08
19.89
19.43
18.49

5HR
17.21
17.11
17.01
16.81
16.39
15.69

8HR
11.66
11.56
11.47
11.37
10.92
10.46

10HR
9.678
9.585
9.492
9.399
9.100
8.831

20HR
5.305
5.209
5.112
5.000
4.748
4.468

Constant Power Discharge Characteristics: W (25 C)(The capacity reaches the peak value after 5-20 cycles.)
F.V/Time
9.60V
10.0V
10.2V
10.5V
10.8V
11.1V

5MIN
2626
2574
2545
2344
2159
1919

10MIN 15MIN
1974
1581
1914
1556
1863
1538
1755
1485
1637
1388
1497
1264

All mentioned values are average values

30MIN
1070
1069
1067
1062
1057
1005

1HR
673.7
672.1
666.9
660.9
641.9
614.4

( Tolerance 2%) .

2HR
413.7
411.5
409.0
406.1
400.9
386.0

3HR
302.9
302.3
301.0
299.8
291.6
279.0

4HR
241.6
241.3
240.8
238.5
233.1
221.8

5HR
205.3
204.8
204.1
201.7
196.7
188.3

8HR
139.2
138.5
137.6
136.5
131.0
125.5

10HR
115.7
114.9
113.9
112.8
109.2
106.0

20HR
63.61
62.50
61.35
60.00
56.97
53.62

DG12-100

(12V100Ah)
Storage characteristic

Life characteristics of cyclic use

100

120

Supplementary charge required


(Carry out supplementary charge
before use if 100% capacity is
requires)

Capacity (%)

Capacity(%)

100
80
60
100%
D.O.D

80%
D.O.D

50%
D.O.D

30%
D.O.D

15%
D.O.D

40

80
10

Supplementary charge required


before use.
This supplementary charge will help
to recover the capacity and should
be made as early as possible.

60
20

40

30

40

Supplementary charge may often


fail to recover the capacity.
The battery should never be left
standing till this state is reached

20
20

0
400

800

1200

1600

2000

2400

Storage Time (months)

Number of Cycle(Times)

Charge characteristic curve for cyclic use

Discharge characteristic curve

15

120

0.24

100

0.20

13

Charge Volume

14

Supplementary charge and storage


guidelines

8 10 12 14 16 18 20 22 24

Charge Voltage

12

11

60

40

0.16

0.12

0.08

T erm inal V oltage (V )

80
Discharge
100%(0.05CA20h)
50%(0.05CA10h)
Charge
Charge Voltage2.275V/C
Charge Current0.1CA
Temperature 25

C h a rg e C u rre n t (C A )

13

C h a rg e V o lu m e (% )

C h a rg e V o lta g e V

12

11
0.05C
0.16C 0.093C
0.35C
0.62C

10
1C

3C

10

20

0.04

Charge Current

9
0

0.6

1.2

12

30

10 12 14 16 18 20 24 28

10

20

24

Hr

min
Discharge Time

Charge Time(h)

Capacity Factors With Different Temperature


Battery Type

-20

-10

10

20

25

30

40

45

GEL
Battery

6V&12V

50%

70%

83%

85%

90%

98%

100%

102%

104%

105%

2V

60%

75%

85%

88%

92%

99%

100%

103%

105%

106%

AGM
Battery

6V&12V

46%

66%

76%

83%

90%

98%

100%

103%

107%

109%

2V

55%

70%

80%

85%

92%

99%

100%

104%

108%

110%

Discharge Current VS. Discharge Voltage


Final Discharge
Vo ltage V /cell

1.75V

Discharge
Current (A)

A 0.2C

Maintenance & Cautions


1.60V

1.70V

Cycle service
0.2C A 1.0C

A 1.0C

Avoid battery over discharge, especially battery sereis connection use.

Charge the batteries at least once every six months,


o

if they are stored at 25 C.

Charged with recommend voltage, ensure battery can be full recharged.


In general, recharge capacity should be 1.1-1.15 times discharge capacity.

Charging Method:
Constant Voltage

-0.2Cx2h+14.4-14.7Vx24h,Max. Current 0.2C

Constant Current

-0.2Cx2h+0.1Cx12h

Fast

-0.2Cx2h+0.2Cx6h

Effect of temperature on cycle charge voltage: -4mV//Cell.


There are a number of factors that will affect the length of cyclic service.
The most significant are depth of discharge, ambient temperature,

Bolt

M5

M6

M8

Terminal

F3 F4 F13 F18 T25 T26

F8 F11 F12-1 F15

F5 F9 F10 F12 F14 F16

Torque

6~7N-m

8~10N-m

10~12N-m

SHEN ZHEN RITAR POWER CO.,LTD.


URL:www.ritarpower.com

discharge rate, and the manner in which the battery is recharged.


Generally specking, the most important factors is depth of discharge.

Address: Rm405,Tower C, Huahan Building,Langshan Rd16, Nanshan District, ShenZhen, 518057, China

Tel:+86-755-33981668 Fax:86-755-8347-5180

2015 - Version 0