Vous êtes sur la page 1sur 8

BULLETIN WS

DUAL L
Air,Water,OdorSolutions Ve r t i c a l a n d
A Met-Pro Product Recovery/Pollution Control Technologies Business

Horizontal
We t S c r u b b e r s
FOR AIR POLLUTION CONTROL

Packaged systems for


easy installation

Professionally
engineered and
certified for
structural integrity

Corrosion and UV
resistant PVC, PP,
CPVC, PVDF,
stainless steel and
DUALLast™ FRP
Construction

Hot gas and


extrusion welded per
AWSG1.10 standards

Hydrostatically
tested at factory

K n o w n f o r o u r q u a l i t y,
Proven to be dependable
Features and Benefits of
Duall Series F, FW, and PT Scrubbers
• P. E. certified for long-term structural integrity • PVC or CPVC Schedule 80 piping
• Thermoplastic construction for maximum corrosion resist- • Full union PVC or CPVC ball valves
ance • Sealless vertical pumps (factory mounted)
• UV-resistant PVC, polypropylene and polyethylene available • Packing removal door
for all outdoor installations
• Differential pressure gauge
• Hot gas and extrusion welded construction per AWS Gl.10
standards • Fresh water flow meter

• Hydrostatically tested at factory • Heavy-duty flanges

• Heavy duty, leak resistant, bolt-on doors • Heavy-duty scrubber bottom

• Full cone spray nozzles • Integral coated steel base


• Stainless steel hardware

FW303 AND FW305 V ERTICAL F UME S CRUBBERS


WITH I NTEGRAL FANS AND S ELF -C ONTAINED R ECIRCULATION S YSTEMS
These packed tower-type fume scrubbers are space-savers.They incorporate a rugged built-in fan to eliminate the need for a fan base
and connecting duct work between the fan and scrubber This feature makes the FW303 and FW305 economical models. Standard
sizes up to 17,500 CFM are available. Remote circulation systems available.

MODEL MAX FAN FAN DRY PUMP QTY.


NUMBER CFM A B C D E F G H J I.D. K I.D. NO. H.P. WT. AND H.P.
FW303-20S 900 20 85⁄8ø 20 46 3 133 33 5 63⁄4 6 2 687 (1)1 H.P.
FW303-26S 1,800 26 103⁄4ø 26 52 3 139 34 61⁄2 9 8 5 748 (1)1 H.P.
FW303-32S 2,800 32 123⁄4ø 32 58 3 145 35 73⁄4 12 10 71⁄2 801 (1)2 H.P.
FW303-34S 3,200 34 16ø 34 60 3 153 37 113⁄4 155⁄8 30 71⁄2 841 (1)2 H.P.
FW303-40S 4,500 40 18ø 40 66 3 159 38 131⁄8 171⁄8 33 71⁄2 935 (1)2 H.P.
FW303-45S 5,500 45 20ø 45 71 3 164 39 141⁄2 19 36 10 1,199 (1)2 H.P.
FW303-49S 6,600 49 24ø 49 75 3 170 41 175⁄8 231⁄4 44 10 1,271 (1)2 H.P
FW303-53S 7,500 53 24ø 53 79 3 174 41 175⁄8 231⁄4 44 15 1,462 (1)2 H.P.
FW303-57S 9,000 57 24ø 57 83 3 179 41 191⁄2 251⁄2 49 15 1,514 (1)5 H.P.
FW303-64S 11,000 64 14 48 78 90 3 170 36 191⁄2 251⁄2 49 15 2,026 (1)5 H.P.
FW303-70S 13,500 70 16 48 84 96 4 177 38 211⁄2 281⁄8 54 20 2,224 (1)5 H.P.
FW303-74S 15,000 74 16 52 88 100 4 180 38 233⁄4 311⁄4 60 20 2,246 (1)5 H.P.
FW303-80S 17,500 80 16 56 94 106 4 187 38 261⁄4 343⁄8 66 25 2,344 (1)71⁄2 H.P.
DIMENSIONS IN INCHES

MODEL MAX FAN FAN DRY PUMP QTY.


NUMBER CFM A B C D E F G H J I.D. K I.D. NO. H.P. WT. AND H.P.
FW305-20S 900 20 85⁄8ø 32 46 3 157 33 5 63⁄4 6 3 729 (1)1 H.P.
FW305-26S 1,800 26 103⁄4ø 38 52 3 163 34 61⁄2 9 8 5 790 (1)1 H.P.
FW305-32S 2,800 32 123⁄4ø 44 58 3 169 35 73⁄4 12 10 71⁄2 843 (1)2 H.P.
FW305-34S 3,200 34 16ø 46 60 3 177 37 113⁄4 155⁄8 30 71⁄2 883 (1)2 H.P.
FW305-40S 4,500 40 18ø 52 66 3 183 38 131⁄8 171⁄8 33 71⁄2 1,109 (1)2 H.P.
FW305-45S 5,500 45 20ø 59 71 3 188 39 141⁄2 19 36 10 1,283 (1)2 H.P.
FW305-49S 6,600 49 24ø 63 75 3 194 41 175⁄8 231⁄4 44 10 1,355 (1)2 H.P
FW305-53S 7,500 53 24ø 67 79 3 198 41 175⁄8 231⁄4 44 15 1,546 (1)2 H.P.
FW305-57S 9,000 57 24ø 71 83 3 203 41 191⁄2 251⁄2 49 15 1,598 (1)5 H.P.
FW305-64S 11,000 64 14 48 78 90 3 194 36 191⁄2 251⁄2 49 15 2,152 (1)5 H.P.
FW305-70S 13,500 70 16 48 84 96 4 201 38 211⁄2 281⁄8 54 20 2,350 (1)5 H.P.
FW305-74S 15,000 74 16 52 88 100 4 204 38 233⁄4 311⁄4 60 20 2,372 (1)5 H.P.
FW305-80S 17,500 80 16 56 94 106 4 211 38 261⁄4 343⁄8 66 25 2,470 (1)71⁄2 H.P
DIMENSIONS IN INCHES

2
P ERFORMANCE D ATA FW BLOWER SECTION
The top section of the FW fume scrubber consists of a Duall
DESCRIPTIONS centrifugal blower complete with TEFC motor and OSHA belt
Contaminant removal is achieved by absorption of gases and shaft guards. The blower section may be rotated
and vapors, condensation of condensable vapors and through 360° to obtain any desired angle between scrubber
impaction of aerosols. All mechanisms occur in a packed inlet and blower outlet. This blower section utilizes the same
bed for intimate gas-liquid contacting. Contaminants trans- low-maintenance, guaranteed corrosion-resistant blower
ferred to the liquid phase are removed from the scrubber described in Duall Brochure No. CINH 151.
by continuous or periodic overflow of blowdown.
F103 and F105 Packed Bed Wet Scrubber. Horizontal
crossflow design minimizes height requirement and is ideal MAINTENANCE
for roof mounting with remote recirculation. Standard units The Duall fume scrubber incorporates low-maintenance
up to 63,000 CFM. components in its entirety, including the packing, plumbing
system and eliminators. Spray header access doors,
FW303 and FW305 Packed Bed Wet Scrubber. Integral fan differential pressure gauges, heavy duty flanges, packing
makes this vertical counterflow unit very compact. Standard removal doors are all critical points differentiating the
units up to 17,500 CFM.
PT503 and PT505 Packed Bed Wet Scrubber. Maximizes 3 Ft Bed With pH 5 Ft.Bed With pH
CONTAMINANT Series Control Series Control
mass transfer efficiency while minimizing footprint require-
Acetic Acid NR 80-85 NR 90-95
ment. Standard units up to 25,000 CFM. Alcohols 3 * * * *
Alkaline Cleaners 4 99.5-99.9 99.5-99.9 99.9 99-9
Amines NR 90-95 NR 98-99
MIST ELIMINATION Ammonia
Aqua Regia 1, 5
NR
85-90
90-95
86-92
NR
95-98
98-99
96-98
Turbulent gas-liquid contacting causes some droplets to Arsine 2 NR 80-85 NR 85-90
become entrained in the air. The mist eliminator collects Boric Acid 4
Caustic Cleaners 4
96-98
99.5-99.9
96-98
99.5-99.9
98
99.9
98
99.9
these droplets that would otherwise be ejected from the Caustic Soda 4 99.5-99.9 99.5-99.9 99.9 99.9
scrubber. Chlorine6 NR 85-90 NR 95-98
Chromic Acid 4 98-99 98-99 99 99
Copper Chloride 4 90-92 90-92 92 92
Cyanide Solutions 4 99.5-99.9 99.5-99.9 99.9 99.9
WATER SUPPLY Diborane 2 NR 90-95 NR 95-98
Ethylene Oxide 3 * * * *
All Duall fume scrubbers must be supplied with water. It is Ferric Chloride 4 93-95 93-95 95 95
generally recommended that a recirculation system be used Ferric Nitrate 4 98-99 98-99 99 99
to conserve water unless once through water is advanta- Ferrous Chloride 4
Ferrous Sulfate 4
98-99
98-99
98-99
98-99
99
99
99
99
geous to meet performance requirements. The actual fresh- Fluoborate Mists 4 98-99 98-99 99 99
water consumption with recirculation is only 0.1 to 0.7 Fluosilicic Acid 4 98-99 98-99 99 99
Formaldehyde NR 85-90 NR 98-99
gpm/1000 cfm* depending on the contaminant involved. Halide Mists 4 96-98 96-98 98 98
Duall scrubbers with remote recirculation systems are self- Hydrochloric Acid 1, 5 90-95 92-96 95-99 98-99
Hydrofluoric Acid 1 95-98 96-98 96-99 98-99
draining and may be installed outdoors in sub-zero condi- Hydrofluosilicic Acid 4 98-99 98-99 99 99
tions without freeze-up. If these conditions exist, the recircula- Hydrogen Cyanide 1,2 NR 85-90 NR 95-98
Hydrogen Peroxide 90-95 90-95 95-99 95-99
tion tank should be placed in a heated area. Hydrogen Sulfide 2 NR 70-75 NR 85-90
Mercaptans 3 * * * *
A complete chemical metering and pumping system is avail- Nickel Chloride 4 93-95 93-95 95 95
able upon request. For applications involving gases with low Nickel Sulfate 4 98-99 98-99 99 99
Nitric Acid 1, 5 85-90 86-92 95-98 96-98
solubility, chemical addition is required for liquid recircula- Nitric Oxide (NO) 3 * * * *
tion. Nitrogen Dioxide (NO2)3 * * * *
Perchloric Acid 5 80-85 80-85 85-90 95-98
* Fresh-water consumption can vary depending on the Phenol 2 NR 70-75 NR 85-90
solubility of contaminants. Phosphine 2 NR 85-90 NR 90-95
Phosphoric Acid 4 96-99 96-99 98-99 98-99
Potassium Dichromate 4 98-99 98-99 99 99
Selenium Sulfide 1 98-99 98-99 99 99
INSTALLATION Silane NR 96-98 NR 99
Every Duall fume scrubber is shipped completed with an Sodium Chloride 4
Sodium Fluoride 4
98-99
98-99
98-99
98-99
99
99
99
99
integral coated steel base. No special mounting is required. Sodium Glutenate 4 98-99 98-99 99 99
Simply connect the duct, the water and power supply, and Sodium Hydroxide 4 99.5-99.9 99.5-99.9 99.9 99.9
Sulfamate Mists 4 98-99 98-99 99 99
the unit is ready for operation. Complete installation and Sulfur Dioxide NR 80-85 NR 92-96
operating instructions are supplied with all scrubbers, or Sulfuric Acid 4 99.5-99 9 99.5-99 9 99 9 99.9
Tin Chloride 4 90-95 90-95 95 95
Duall’s trained staff can install equipment quickly and effi- Zinc Chloride 4 90-95 90-95 95 95
ciently. Zinc Nitrate 4 98-99 98-99 99 99
Zinc Sulfate 4 98-99 98-99 99 99

These efficiencies are intended only as a guide. Specific combinations and concentrations of fumes may
PRESSURE DROP result in significant variation from these values.
The following pressure drops are applicable for scrubbers 1. The use of pH control for these applications reduces water usage.
operated at design: 2. Performance is improved by chemical addition (other than for pH control).
3. These applications require extended packing depth and chemical addition (other than for pH control)
F103 2.0" w.g FW305 2.5" w.g. or
once-through water.
F105 2.5" w.g PT503 2.0" w.g.
4. Wet scrubbing is not necessary; only a mist elimination device is needed, such as Duall Mist Misers or
FW303 2.0" w.g PT505 2.5" w.g. Chemical Mist Eliminators. Expected efficiencies on fumes from molten salt baths using the indicated
salt
On the FW series, the blower is designed for 2.0" external will be less than those shown for aqueous mists; efficiencies on molten salt bath applications will range
from 70-90%.
static pressure.
5. Under certain conditions such as high loadings or high process temperature, a fine fog forms which
will
not be removed at the stated efficiencies. A special high efficiency mist eliminator is required.
6. For applications involving high levels of chlorine, consult Duall Division, Met-Pro Corporation.
7
PT503, PT505 AND PT510 VERTICAL FUME SCRUBBERS
WITH SELF-CONTAINED RECIRCULATION SYSTEMS
The PT Series, along with the FW Series, offer maximum efficiency due to their counter flow configuration. Standard PT Series scrubbers
are available in sizes up to 25,000 CFM. Remote recirculation systems available. Large custom units available upon request.

MODEL MAX. DRY PUMP QTY.


NUMBER CFM A B C D E F G H WT. AND H.P.
PT503-20S 1,100 20 85⁄8Ø 85⁄8Ø 46 3 110 33 612 (1)1 H.P.
PT503-26S 1,900 26 10 ⁄4Ø
3
103⁄4Ø 52 3 119 34 673 (1)1 H.P.
PT503-32S 2,800 32 123⁄4Ø 123⁄4Ø 58 3 123 35 726 (1)2 H.P.
PT503-34S 3,200 34 16Ø 16Ø 60 3 124 37 741 (1)2 H.P.
PT503-40S 4,500 40 18Ø 18Ø 66 3 129 38 835 (1)2 H.P.
PT503-45S 5,500 45 20Ø 20Ø 71 3 134 39 1,049 (1)2 H.P.
PT503-49S 6,600 49 24Ø 24Ø 75 3 138 41 1,121 (1)2 H.P.
PT503-53S 7,500 53 24Ø 24Ø 79 3 143 41 1,262 (1)2 H.P.
PT503-57S 9,000 57 24Ø 24Ø 83 3 143 41 1,314 (1)5 H.P.
PT503-64S 11,000 64 14 48 26Ø 90 3 136 36 1,566 (1)5 H.P.
PT503-70S 13,500 70 16 48 30Ø 96 4 140 38 1,764 (1)5 H.P.
PT503-74S 15,000 74 16 52 30Ø 100 4 143 38 1,786 (1)5 H.P.
PT503-80S 17,500 80 16 56 32Ø 106 4 146 38 1,884 (1)71⁄2 H.P.
PT503-84S 19,000 84 17 60 36Ø 110 4 149 39 2,160 (1)71⁄2 H.P.
PT503-88S 21,000 88 18 64 36Ø 114 4 151 39 2,448 (1)71⁄2 H.P.
PT503-92S 23,000 92 18 68 42Ø 118 4 152 39 2,638 (1)71⁄2 H.P.
PT503-96S 25,000 96 18 72 42Ø 122 4 155 39 2,827 (1)71⁄2 H.P
DIMENSIONS IN INCHES

MODEL MAX. DRY PUMP QTY.


NUMBER CFM A B C D E F G H WT. AND H.P.
PT505-20S 1,100 20 85⁄8Ø 85⁄8Ø 46 3 134 33 654 (1)1 H.P.
PT505-26S 1,900 26 103⁄4Ø 103⁄4Ø 52 3 143 34 715 (1)1 H.P.
PT505-32S 2,800 32 123⁄4Ø 123⁄4Ø 58 3 147 35 768 (1)2 H.P.
PT505-34S 3,200 34 16Ø 16Ø 60 3 148 37 783 (1)2 H.P.
PT505-40S 4,500 40 18Ø 18Ø 66 3 153 38 919 (1)2 H.P.
PT505-45S 5,500 45 20Ø 20Ø 71 3 158 39 1,133 (1)2 H.P.
PT505-49S 6,600 49 24Ø 24Ø 75 3 162 41 1,205 (1)2 H.P.
PT505-53S 7,500 53 24Ø 24Ø 79 3 167 41 1,346 (1)2 H.P.
PT505-57S 9,000 57 24Ø 24Ø 83 3 167 41 1,398 (1)5 H.P.
PT505-64S 11,000 64 14 48 26Ø 90 3 160 36 1,692 (1)5 H.P.
PT505-70S 13,500 70 16 48 30Ø 96 4 164 38 1,890 (1)5 H.P.
PT505-74S 15,000 74 16 52 30Ø 100 4 167 38 1,912 (1)5 H.P.
PT505-80S 17,500 80 16 56 32Ø 106 4 170 38 2,010 (1)71⁄2 H.P.
PT505-84S 19,000 84 17 60 36Ø 110 4 173 39 2,286 (1)71⁄2 H.P.
PT505-88S 21,000 88 18 64 36Ø 114 4 175 39 2,700 (1)71⁄2 H.P.
PT505-92S 23,000 92 18 68 42Ø 118 4 176 39 2,890 (1)71⁄2 H.P.
PT505-96S 25,000 96 18 72 42Ø 122 4 179 39 3,079 (1)71⁄2 H.P.
DIMENSIONS IN INCHES

MODEL MAX. RECYCLE DRY VERT. PUMP


NUMBER CFM Aø Bø C D E F G RATE WT. QTY. & H.P.
PT510-24 1,500 24 123⁄4 123⁄4Ø 234 42 20 20 900 (1)2 H.P.
PT510-36 3,500 36 16 16Ø 238 44 20 46 1,600 (1)3 H.P.
PT510-48 6,500 48 20 20Ø 244 46 20 82 2,300 (1)3 H.P.
PT510-60 10,500 60 26 26Ø 248 49 20 126 2,700 (1)5 H.P.
PT510-72 15,500 72 30 30Ø 252 51 40 185 4,300 (2)5 H.P.
PT510-84 21,000 84 36 19 53 257 45 40 250 5,700 (2)5 H.P.
PT510-96 27,500 96 42 20 62 252 46 40 326 6,900 (2)71⁄2 H.P.
DIMENSIONS IN INCHES

4
Custom designed scrubbers for specialty applications
T YPICAL A PPLICATIONS
• Metal Finishing NOx • Refineries • Pesticides • Rendering • Painting
• Industrial Wastewater • Medical • Animal Food • Pharmaceutical • Breweries
• Municipal Wastewater • Foundries • Pulp and Paper • Tanning • Textile
• Food Processing • Chemical • Fish Processing • Battery Manufacturing

APPLICATION: APPLICATION:
Pharmaceutical Anodizing of
Aluminum
PROBLEM :
Odor PROBLEM:
NOx (Orange Plume)
SOLUTION: Emissions
DUALL Multi-Stage
System SOLUTION:
DUALL ßeta NOx
CONSTRUCTION: 2000®
U.V. Stabilized Multi-Stage NOx
Polypropylene System

CONSTRUCTION:
U.V. Stabilized
Polypropylene

Control of
NOx gases

Typical
ßeta NOx
2000® Layout
5
Standard Features

MIST ELIMINATOR
PVC Chevron blades are the core of the F Series fume
scrubbers’ mist eliminator. Four (4) 30% air directional
SPRAY NOZZLES changes take place impinging droplets to the blades which
Full cone non-clogging, polypropylene nozzles are specified then drain off. This results in less static pressure and makes
with every standard Duall scrubber. the eliminator practically maintenance-free. Molded
polypropylene packing is standard for PT and FW models.
HIGH EFFICIENCY MASS TRANSFER
Duall’s standard media is corrosion-resistant molded
polypropylene random dumped packing. Free space is a RECIRCULATION PUMP
minimum of 93%, making for a maintenance-free low pres- Vertical sealless or
sure drop packing. end-suction horizon-
tal corrosion-resist-
Several other types of packing may be used in custom ant pumps are speci-
designed scrubbers. Duall’s engineers select the best pack- fied, depending on
ing for a specific application. the project require-
ments. Pump and
INSPECTION DOORS motor are factory
Inspection doors are standard for ease of inspection at all mounted.
critical points.

Optional Features
The internal components of the panel are prewired. A ter-
minal strip is provided for attachment of power and control
lines in the field.
CHEMICAL ADDITION CONTROL PACKAGE
The pH, ORP and conductivity control systems can be used SYSTEM MONITORING CONTROL PACKAGE
with any new or existing scrubber installation. It will auto- A monitoring package is available when monitoring of
matically regulate the addition of either acid or alkaline system “vital signs” is required by local regulatory agencies.
reagents to the scrubbing solution enhancing the removal Important parameters to be monitored would include air
of contaminants by the fume scrubber. flow rate, recirculating liquid flow rate, pressure drop and
solution chemistry.
The pH control system consists of an enclosure, probe, a
meter/analyzer and a chemical metering pump. It operates MOTOR CONTROL PACKAGE
on 120 volts electrical power. A motor starter panel with fused disconnect is available for
The probe is heavy-duty industrial grade. The probe comes start-stop motor control. Standard panel includes fan and
with 10 feet of cable attachment to the analyzer. recirculation pump control, based on 460 volt/3 Ph/60 Hz.
power supply.
The meter/analyzer has a weather-tight, corrosion resistant
(NEMA 4X) enclosure. The analyzer is a state-of-the-art COMPLETE SYSTEM CONTROL PACKAGE
digital unit with one (1) 4-20 mA output for proportional A system control package is available which combines all
control. of the above functions, if applicable, into a single panel.
The metering pump delivers up to 5.5 gph and a maximum Contaminant removal is achieved by adsorption of gases
pressure of 150 psi. and vapors, condensation of condensable vapors and
impaction of aerosols. All mechanisms occur in a packed
The analyzer is housed in a corrosion-resistant, NEMA 4 bed for intimate gas-liquid contacting. Contaminants trans-
enclosure that is fabricated from FRP. The panel is suitable ferred to the liquid phase are removed from the scrubber
for wall mounting. by continuous or periodic overflow of blowdown.

6
F103 AND F105 HORIZONTAL FUME SCRUBBERS WITH SELF-CONTAINED RECIRCULATION SYSTEMS
Horizontal fume scrubbers are offered in standard sizes from 500 to 63,000 CFM. They are ideal when a low profile
is a necessity. The F103 and F105 incorporates an overhead weir to insure complete saturation of filter media. Remote
recirculation systems available.

MODEL MAX. DRY PUMP QTY


NUMBER CFM A B C D E F CL WEIGHT AND H.P.
F103-18S 500 18 10 39 44 3 2 34 642 (1)1 HP
F103-22S 1,000 22 14 43 48 3 2 36 796 (1)1 HP
F103-28S 2,000 28 20 49 54 3 2 39 895 (1)1 HP
F103-32S 2,700 32 24 53 58 3 2 41 942 (1)2 HP
F103-37S 3,700 37 29 58 63 3 2 43⁄2 1,020 (1)2 HP
F103-41S 4,700 41 33 62 67 3 2 451⁄2 1,133 (1)2 HP
F103-45S 6,000 45 37 66 71 3 2 471⁄2 1,212 (1)2 HP
F103-52S 8,000 52 44 73 78 3 2 51 1,329 (1)2 HP
F103-58S 10,000 58 49 78 84 3 3 531⁄2 1,456 (1)2 HP
F103-64S 12,000 64 54 83 90 3 3 56 1,561 (1)2 HP
F103-69S 14,000 69 59 88 95 3 3 58⁄2 1,925 (1)2 HP
F103-74S 16,000 74 64 93 100 3 3 61 1,947 (1)5 HP
F103-79S 18,000 79 67 97 105 4 3 631⁄2 1,967 (1)5 HP
F103-84S 21,000 84 71 101 110 4 3 651⁄2 2,143 (1)5 HP
F103-90S 23,000 90 73 103 116 4 3 661⁄2 2,347 (1)5 HP
F103-96S 25,000 96 73 103 122 4 3 661⁄2 2,491 (1)5 HP
F103-104S 27,000 104 73 103 130 4 3 661⁄2 2,777 (1)5 HP
F103-112S 30,000 112 73 103 138 4 3 661⁄2 3,097 (1)5 HP
F103-123S 32,500 123 73 103 149 4 3 661⁄2 3,217 (1)5 HP
F103-135S 35,000 135 73 103 161 4 3 661⁄2 3,565 (1)71⁄2 HP
F103-157S 40,000 157 73 103 183 4 3 661⁄2 4,076 (1)71⁄2 HP
F103-179S 45,000 179 73 103 205 4 3 661⁄2 4,488 (1)71⁄2 HP
F103-202S 52,000 202 73 103 228 4 3 661⁄2 4,932 (1)71⁄2 HP
F103-224S 57,000 224 73 103 250 4 3 661⁄2 5,374 (1)71⁄2 HP
F103-247S 63,000 247 73 103 273 4 3 661⁄2 5,788 (1)71⁄2 HP
DIMENSIONS IN INCHES

MODEL MAX. DRY PUMP QTY


NUMBER CFM A B C D E F CL WEIGHT AND H.P.
F105-18S 500 18 10 39 44 3 2 34 784 (1)2 HP
F105-22S 1,000 22 14 43 48 3 2 36 942 (1)2 HP
F105-28S 2,000 28 20 49 54 3 2 39 1,094 (1)2 HP
F105-32S 2,700 32 24 53 58 3 2 41 1,148 (1)2 HP
F105-37S 3,700 37 29 58 63 3 2 43⁄2 1,237 (1)2 HP
F105-41S 4,700 41 33 62 67 3 2 451⁄2 1,398 (1)2 HP
F105-45S 6,000 45 37 66 71 3 2 471⁄2 1,491 (1)5 HP
F105-52S 8,000 52 44 73 78 3 2 51 1,654 (1)5 HP
F105-58S 10,000 58 49 78 84 3 3 531⁄2 1,849 (1)5 HP
F105-64S 12,000 64 54 83 90 3 3 56 1,997 (1)5 HP
F105-69S 14,000 69 59 88 95 3 3 58⁄2 2,437 (1)5 HP
F105-74S 16,000 74 64 93 100 3 3 61 2,468 (1)5 HP
F105-79S 18,000 79 67 97 105 4 3 631⁄2 2,561 (1)71⁄2 HP
F105-84S 21,000 84 71 101 110 4 3 65 ⁄2
1
2,746 (1)71⁄2 HP
F105-90S 23,000 90 73 103 116 4 3 66 ⁄2
1
2,990 (1)71⁄2 HP
F105-96S 25,000 96 73 103 122 4 3 66 ⁄2
1
3,173 (1)71⁄2 HP
F105-104S 27,000 104 73 103 130 4 3 66 ⁄2
1
3,524 (1)71⁄2 HP
F105-112S 30,000 112 73 103 138 4 3 66 ⁄2
1
3,918 (1)71⁄2 HP
F105-123S 32,500 123 73 103 149 4 3 66 ⁄2
1
4,081 (1)71⁄2 HP
F105-135S 35,000 135 73 103 161 4 3 66 ⁄2
1
4,473 (1)71⁄2 HP
F105-157S 40,000 157 73 103 183 4 3 66 ⁄2
1
5,137 (2)71⁄2 HP
F105-179S 45,000 179 73 103 205 4 3 66 ⁄2
1
5,635 (2)71⁄2 HP
F105-202S 52,000 202 73 103 228 4 3 66 ⁄2
1
6,233 (2)71⁄2 HP
F105-224S 57,000 224 73 103 250 4 3 66 ⁄2
1
6,794 (2)71⁄2 HP
F105-247S 63,000 247 73 103 273 4 3 66 ⁄2
1
7,329 (2)71⁄2 HP
DIMENSIONS IN INCHES 3
S PECIFICATIONS Remote Recirculation Tanks: If required, each scrubber will
be furnished with a remote recirculation tank to be con-
EXHAUST GAS SCRUBBERS structed of PVC*. Fittings will be provided on the tank for
Scrubbers shall be designed for specified collection- pump suction, overflow, and drain. Tanks shall be of suffi-
removal efficiency of air contaminants arising from the cient capacity and structural rigidity for intended service.
processes listed herein. Collection efficiencies shall apply to Tank freeboard above the overflow connection shall be of
the unit as a whole, including mist eliminators downstream sufficient volume to contain liquid volume suspended in
of the packing. Overall mass collection efficiency shall be supply and return pipes and scrubbers.Recirculation pumps
___% or better at design gas flow. The collection efficien- shall be mounted on top of tank. Pipe and fittings neces-
cies shall be achieved with a scrubbing solution waste flow sary for connection of pump suction to tank will be fur-
rate of not more than 0.7 gallons per minute per thousand nished.
(1,000) cubic feet per minute of gas flow, and pressure
drop across the entire scrubber unit including the mist elim- Scrubber Packing: The scrubber packing shall be resistant
inator of not more than 2.5 inches water column. to corrosion from all contaminants listed herein. Packing
shall be non-clogging, non-nesting and of such design and
bed depth as to achieve certified collection efficiencies stated
CORROSION RESISTANCE herein. Minimum void volume of packing to be 93%.
1. Scrubbers, including all internals and appurtenances,
shall be completely resistant to chemical corrosion Mist Eliminator: A mist eliminator shall be provided to
from the process chemicals listed herein and shall carry effectively remove entrained water droplets prior to
a warranty against corrosion-induced failure for one leaving the scrubber.
year after initial start-up. Access Panels: Removable access panels for packing
2. Scrubber housings shall be constructed of Type ll, Grade removal and spray nozzle maintenance shall be furnished.
1, high-impact polyvinyl chloride (PVC)* conforming to Transparent view ports to allow for inspection of packing
ASTM D 1784-69 Cell 1433D. Outdoor installation and spray nozzles are also standard.
shall be white PVC for UV resistance. Flow Meter: A flow meter for indicating/adjusting fresh-water
Base: Each scrubber shall be complete with a corrosion- make-up will be furnished. Dwyer instruments Series RM that
resistant coated steel base of sufficient strength to make the clearly indicates design flow on scale will be utilized.
unit self-supporting when wet. Pressure Gauge: All Duall fume scrubbers are supplied
with a pressure gauge to monitor pressure differential
across the filter packing. The Duall specified gauge would
SCRUBBER PIPING be a Dwyer instruments Series 2000 Magnehelic, or equal.
1. Furnish all scrubber internal piping necessary for
recirculation of scrubbing solution such that installer
need only make single external piping connections for OPTIONAL CONTROL PACKAGES
scrubbing solution supply and return. Piping shall be Chemical Addition Control Package: The Duall chemical
polyvinyl chloride (PVC)*. Wherever possible, piping addition control system consists of a weathertight, corro-
shall be installed at the factory. Interior piping to be sion-proof enclosure containing an analyzer, prewired
removable through access doors for maintenance. chemical feed pump and weather-protected terminal block.
Enclosure can be mounted on any vertical surface. A
2. Spray nozzles shall be full cone non-clogging type of heavy-duty industrial probe with a 10-ft. lead wire is sup-
sufficient quantity to insure complete coverage of the plied, along with two 10-ft. lengths of vinyl tubing
packing face. On horizontal scrubbers, overhead spray to connect the feed pump.
headers shall be provided to prevent channeling of the Motor Control Package: A motor starter panel with fused

Printed on Recycled Paper


gas stream. disconnect is available for start-stop motor control.
Pumps: Recirculation pumps shall be vertical sealless cen- Standard panel includes fan and recirculation pump con-
trifugal chemical duty type, constructed of materials com- trol, based on 460 volt / 3 Ph / 60 Hz. power supply.
pletely resistant to corrosion from all contaminants listed
herein. Pump motors shall be single-speed, NEMA Design B, *Optional corrosion-resistant materials are:
Class-B insulated, 230/460 volts, 3-phase, 60-hertz. All • CPVC • Polypropylene • Stainless Steel
external pump and drive components shall be of corrosion- • PVDF • DUALLast FRP™
resistant construction or otherwise epoxy- coated. Pumps
shall be securely mounted to sump box or remote tank.
Pumps shall be sized to handle a minimum of 40 TDH on
self-contained and 70 TDH on remote
recirculation systems.

©COPYRIGHT 2009 MET-PRO CORPORATION, DUALL DIVISION DUALL DIVISION ® IS A REGISTERED TRADEMARK OF MET-PRO CORPORATION 11-5001 0609

DUAL L
Air,Water,OdorSolutions
A Met-Pro Product Recovery/Pollution Control Technologies Business

1550 Industrial Drive, Owosso, MI 48867


(989) 725-8184, FAX: (989) 725-8188
E-mail: info@dualldiv.com, Web Site: www.dualldiv.com

Vous aimerez peut-être aussi