Vous êtes sur la page 1sur 9

PV On/Off-grid Solar ESS Users Manual

PS6530B Series
On/Off-Grid Hybrid Solar Energy Storage System
Thanks for using our products!
Please strictly follow the users manual and pay attention to the warnings
on the product.
Please do not operate before reading users manual.

Contents

1. Brief Introduction
1.1 Foreword

1.Brief Introduction
1.1 Foreword
1.2 Applicable Personnel

2
2
2

1.3 Safety Precautions

2.2 Back&Side Sketch


2.3 Power on/ off Introduction
3. Unpacking
4. Installation
4.1 Installation Precautions
4.2 Wiring Instructions

2
2
2
3
3
4
4
4
4
5

5. Operation

1.4 Use&Maintenance
2. Product Overview
2.1 Appearance

This manual gives detailed product information and instructions for PV on/off-grid
Hybrid Energy Storage System (ESS) (PS6530B series products). Please read this
manual carefully before using them. And please safely keep the manual where is
easily to get by user and maintainer.
1.2 Applicable Personnel
After reading the manual carefully, users can use PS6530B series products
correctly and quickly, you can also make some troubleshooting and build a
communication system.Should any questions during installation, please contact
your locally appointed technical supporter.
1.3 Safety Precautions

5.3.1 Initialization Interface


5.3.2 System Homepage

5
5
6
6
6

5.3.3 System Time Setting

5.3.4 User Setting Interface

5.3.5 System Information

(1) Please read the Safety Precautions before using to ensure right and safe
operation and safely keep the manual. We have the rights of not offering quality
assurance if the product fails when user doesnt follow this manual.
(2) Please notice the warning marks and follow the manual during operation.
(3) Keep the product away from sun, rain and humid conditions.
(4) Keep the product away from heat source, like electric warming oven, furnace, etc.
(5) Keep a safe distance for ventilation and follow the manual when installing.
(6) Please wipe by dry things for cleaning.
(7) Once a re, please use dry powder extinguisher for extinguishment because
uid extinguisher
may cause electric shock hazard.
(8) Except the wiring terminal, please dont disassemble any part inside housing.
(9) Please contact the local appointed installer or maintainer when maintenances
needed.

5.3.6 Language Setting

1.4 Use&Maintenance

5.1 Operation Display Panel


5.2 Power On/Off
5.3 LCD Display and Operation

5.3.7 Administrator System Setting


6. Working Mode Features

10
12

6.1 Peak-Avoiding Mode

12

6.2 Energy-Saving Mode

13

6.3 Economical Mode


6.4 Off-grid Mode

13
13
13
13

7. Communication
8. Troubleshooting
9. Specications
10. Contact Us

14
15

(1) The working and store conditions inuences the using life and reliability of this
product, so please pay attention to avoid the following environment.
Out of the specications (temperature 0~40, relative humidity 5% to 90%) of
high or low temperature and over humid place
Please with vibrations or shocks
Place with metal dust, corrosive substances, salt and ammable gases
2. If do not use the device for a long time, please store it in a dry environment with
temperature from -25 to 55. Before use it again, please warm it up within
ambient temperature above 0 for a period.

2. Product Overview
PS6530B Series is a small on/off-grid hybrid energy storage system, converting DC
power generated by photovoltaic panels to AC electricity, feeding back to grid,
charging built-in battery to store energy. Besides, the peak-avoiding working mode
offers off peak electricity utilization.
It is an emergency power supply for TV or LED lights and other signicant electrical
devices when mains fail.

-1-

-2-

For areas without solar system, user can store power at night when electricity price
is lower and use the stored power during day time when electricity price is high,
which saves electricity charge.The system can feed back electricity generated by
solar panels to grid where on-grid is allowed.

2.3 Power on/off Introduction

grid

bidirectional
rectier
inverter
charger

System Sketch
out put
control

Grid Input Switch

SI

Outer Generator Input Switch

OUT

AC Output Switch

PV

PV Module Input Switch

MB

Maintenance Bypass Switch

AC OUTPUT

AC Output Outlet

PV module

solar
charger

GRID

load

PS6530B
battery

3. Unpacking
Before opening the carton, please check if the package is damaged. After
unpacking, please check if product appearance is damaged or there is missing
parts. If so, please contact us.

2.1 Appearance

PS6530B Series products and accessories are as follows.

347.0

884.0

711.0

No

Item

Quantity

PV On & Off grid Energy Storage System

Users Manual

Warranty Card

4. Installation
2.2 Back&Side Sketch
4.1 Installation Precautions
1. Place the product where is well-ventilated and away from water, ammable
gases, corrosive and other dangerous articles. Installation environment should meet
the specied requirements.
2. Keep the air outlet on housing rear panel and the air intake on housing side
unobstructed.
3. Low temperatures may cause condensation droplets in the product; user must
wait for installation or use until inside and outside of the machine is dry completely.
Otherwise there may be danger of electric shock.
4. PV module should be equipped with lightning protection devices.
5. The product has an on-grid function, and connecting to grid should be in
compliance with local laws and regulations.

-3-

-4-

4.2 Wiring Instructions

5.3 LCD Display and Operation


5.3.1 Initialization Interface
After power on, LCD display shows system initialization interface as below.

Initializing

Please wiring according to below form.

PE

Ground Terminal

GRID-P

Grid Live Wire

GRID-N

Grid Null Wire

SI-P

Generator Live Wire

SI-N

Generator Null Wire

OUT-P

AC Output Live Wire

5.3.2 System Homepage


System homepage after Initialization

OUTN

AC Output Null Wire

PV1-P

PV/RS485 Input Positive

PV2-P

PV/RS485 Input Positive

PV2-N

PV/RS485 Input Negative REMOTE

PV1-N

PV/RS485 Input Negative


Homepage

Setting

System Info

Language

PV/RS485 Communication Port

Note:
(1) Two strings of PV modules, PV1 and PV2, each string maximum input current is
30A.
(2) AC Output Maximum Current:10A

Solar

Power Consumption
HYBRID
SYSTEM

Battery

Grid
Power

5. Operation
5.1 Operation Display Panel

Output Voltage

VAC

PV Voltage

Output Power

PV Power

Output Frequency

Hz

Load Power

Run

Touch the icons or works on LCD to see related information or setting parameters.

display

System Status, including running, stop,


error
The bottom left words indicate the system current working mode.
The other three modes : Energy-Saving Mode, Economical Mode and Peak-Avoiding Mode
Energy Running Path

on/off button

5.2 Power On/Off


(1) Power On: Press on/off button for one second or longer, the LCD display and
button LED light on and system powers on

off-grid
mode

HYBRID
SYSTEM

(2) Power Off: Press on/off button for three seconds or longer, the LCD display and
button LED light off and system powers off

Battery Information

Load/Output Information

Grid Input/Output Information

Maintenance Setting
Interface

Setting

Users Setting Interface

Battery Information
System Info

-5-

PV modules Input Information

System Running Status

Language

Language Setting
-6-

5.3.3 System Time Setting


The bottom right corner of system homepage displays system time and touch the
related area to set system time.

Peak-Avoiding Mode

Back

Charge Time

5.3.4 User Setting Interface


Touch Setting area of system homepage to users setting interface.

Start

End

Start

End

Discharge Time
Homepage

Setting

Language

System Info

Parameter Setting
Min Capacity Retention:

Max Capacity Retention:

%
V

System Output Voltage:


System Output Frequency:

50HZ

60HZ

5.3.4.3 User Password Setting

Working Mode Setting


Peak-Avoiding
Mode

Energy-Saving
Mode

Economical
Mode

Off Grid
Mode

Charge
Discharge Time

Password
Settings

Factory Reset

Alarm
Settings

Change Password

Back

Change Password

Touch the gures after "Minimum Battery Capacity Retention Percentage",


"Maximum Battery Capacity Retention Percentage", "Inverter Output Voltage", and
Inverter Output Frequency".
Note: Please carefully check the local conditions before changing the above
parameters.

Old Password

New Password
Yes

No

5.3.4.1 Working Mode Setting


Choose one from four working modes from Peak-Avoiding Mode, Energy-Saving
Mode, Economical Mode and Off Grid Mode.
For example: Touch Peak-Avoiding Mode, then next page as below.
5.3.4.4 Factory Reset Setting
Peak-Avoiding Mode

Yes

No

The system can store electricity when rates are low


and power your home when rates are high based on
the setting charge and discharge time. When mains
supply fails, system offers uninterrupted power
supply. Besides, PV can also charge the system.

Factory Reset

Back

Factory Reset

Factory ResetYes/No

Touch Yes or No to conrm or back respectively.


Yes

No

5.3.4.2 Peak-Avoiding Mode Setting


After conrming Peak-Avoiding Mode, next step should be set the Peak-Avoiding
time.
Touch Peak-Avoiding Time below Peak-Avoiding Mode.

-7-

-8-

5.3.4.5 Alarm/Buzzer Setting

Buzzer On/Off

Yes

No

5.3.7 Administrator System Setting


5.3.5 System Information
Touch System Info area on system homepage to check system running status
and alarm information.

Touch

HYBRID
SYSTEM

on system homepage and input passwords to administrator

setting page.
Administrator Password Login

Homepage

Setting

System Info

Current Sensor Failure

Battery Over Temp

Voltage Sensor Failure

Over Ambient Temp

Communication Failure

Controller Over Temp

Language

Password Login

Inverter Output Failure

Transformer Over Temp

Low Battery Voltage

Low Grid Frequency

High Battery Voltage

High Grid Frequency

Inverter Over Heat

Low Grid Voltage

Inverter Over Load

High Grid Voltage

Back

Yes

Back

Note: Only professional or after-service technician can login !

Next Page

Note: administrator setting is only for professional, maintainer or other after-service


technician.
Type in correct password to access and next page as below.
Homepage

Setting

System Info

Language

Current Sensor Failure

Administrator Maintenance

Communication breakdown

Back

Radiator Over Temperature


Fan Failure

Bi-directional Inverter Setting

Low PV Voltage
PV Charger Setting

High PV Voltage
Charger Over Load

BMS Setting

Battery Pack Failure


Temperature Sensor Failure

Password Settings

Back
Forced Charge/Discharge Setting

5.3.6 Language Setting


Touch Language area on system homepage to set system language.

-9-

5.3.7.1 Bi-directional Inverter Setting


-10-

5.3.7.4 Password Setting


Bi-directional Inverter Setting

Back

System Output Voltage

VAC

AC Maximum Charge Current

AC Maximum Discharge Current

Password Settings

Back

Change Password
Old Password

New Password
Yes

No

Inverter Maximum Charge Current stands for battery maximum charge current
from grid.Inverter Maximum Discharge Current stands for the maximum feedback
current to grid.
This password is only for Administrator Setting.

5.3.7.2 PV Charger Setting

5.3.7.5 Forced Charge/Discharge Setting


PV Charger Setting

Back

Forced Charge/Discharge Setting


PV Maximum Charge Current

Back

A
1

Choose Debugging Mode

Debugging Mode

Choose Forced Charge/Discharge

Forced Charge

Forced Discharge

PV Maximum Charge Current refers to the maximum charge current for battery
from PV module.PV Maximum Charger Voltage refers to the maximum charge
voltage for battery from PV module.
5.3.7.3 BMS Setting

Battery Information

Back

Battery Voltage

Maintainer can force the system to charge battery from AC power supply or
discharge, and can also enter debug mode (for manufacturers only).

6. Working Mode Features

Battery Current

Battery Temperature

Batter y Information

Under any certain working mode, system use solar energy rstly and choose energy
source automatically based the custom setting parameters or defaults. Besides,
system offers uninterrupted power supply automatically when mains fail.

Series Voltage Series Voltage Series Voltage Series Voltage


1

13

10

14

11

15

12

16

This page tells detailed battery information including battery single cell voltage.
-11-

6.1 Peak-Avoiding Mode


The system can store electricity when rates are low and power your home when
rates are high based on the setting charge and discharge time. When mains supply
fails, system offers uninterrupted power supply. Besides, PV can also charge the
system.
-12-

6.2 Energy-Saving Mode


Solar generation satises home needs and surplus energy feeds back to grid for prot.
When mains supply fails, system offers uninterrupted power supply automatically.
6.3 Economical Mode
Solar generation satises home needs and surplus energy doesnt feed back to grid.
When mains supply fails, system offers uninterrupted power supply automatically.

For PV module
Solar panels manufacturer name and Model number
Solar panels output power
Solar panels output voltage
Solar panels MPPT output voltage
Solar panels MPPT output current
Solar panel quantity

9. Specications

6.4 Off-grid Mode


System doesnt feed energy back to grid. When mains supply fails, system offers
uninterrupted power supply automatically.

The product offers RS-485 communication interface and the interface denition as
follows

Item
RS485-B
GND

No.
2
6

Item
RS485-A
GND

No.
3
7

Item
NC
NC

No.
4
8

Item
NC
NC

8. Troubleshooting
Our products have been tested strictly before delivery. If you have any difculty
during installation or operation, please contact your local technical supporter or
contact us.
When the machine fails, please inform us and provide product related information.
We have professional after-sale service staff to respond.
Information as follows
For our product
Series number
Model number
LCD display alarm information
Grid voltage
DC input voltage
Can you repeat this failure problem?
Did this problem happen before?
What probably caused this problem?

-13-

PS6520B

OUTPUT

7. Communication

No.
1
5

PS6530B

Storage Capacity

6.5kWh

Work Model

On&Off Grid Hybrid

UPS Function

Yes

Yes

Nominal AC Output Power

3000 W

2000W

Maximum AC Output Power

4500 W

3000 W

AC Voltage (Input&Output)

230Vac

110Vac

Nominal Frequency

50Hz

60Hz

Nominal Output Current

13A

18A

Maximum Output Current

19.5A

27A

Feed Back to Grid

Yes

Yes

Energy Consumption

Programming Control

Maximum Efciency

>92.5%

6.5kWh
On&Off Grid Hybrid

Programming Control
>92.5%

PV INPUT
Maximum Input Power

2400 W

2400W

Start-up Voltage

80 V

80V

MTTP Strings Amount

MTTP Voltage Range

70V-120V

70V-120 V

Maximum Input Current

30A

30 A

Maximum Input Voltage

150V

150V

Maximum Efciency

>97%

>97%

-14-

BATTERY
Battery Management System

YES

YES

Rated Capacity

128Ah

128Ah

Rated Voltage

51.8V

51.8V

ELECTRICAL PROTECTIONS
DC/AC protection

Yes

Yes

DC lightning arrester

Yes

Yes

Batteries protection

Fuse

Fuse

GENERAL
IP Protection

IP 21

IP 21

Connectivity

Cable Terminals

Cable Terminals

Connectivity

Cable Terminals

Cable Terminals

Communication

RS485

RS485

Humility: 5% - 90%

Humility: 5% - 90%

Using Conditions

Temperature:
0-40 (Charge )
-20-50 (Discharge)

Temperature:
0-40 (Charge )
-20-50 (Discharge)

Warranty

2years,5years optional

2years,5years optional

Ventilation Location

Side

Side

Dimensions

L710* W350*H895 mm

L710* W350*H895 mm

Weight

125kg

120kg

10. Contact
Should you have any technical questions, please contact your installer.
Following information needed:
1.Model Number
2.Module Information
3.Communication way
4.Series Number
5.Error Information
6.Display information

-15-

Vous aimerez peut-être aussi