Académique Documents
Professionnel Documents
Culture Documents
Receive
High byte
Low byte
Total 2 byte
Receive
x1000
x100
x10
x1
$0A
$0D
Total 6 byte
Receive
High byte
Low byte
High byte
Ch.0
Low byte
...
High byte
Ch.1
Low byte
High byte
Ch.6
Low byte
Ch.7
Total 16 byte
Receive
QX-108 Revision name + $0A +$0D
Total 16 byte
3. PC software
3.1 GraphTrend
This software displays the single channel graph. User can select any channel
to display value and sampling rate. Select read time in range 10ma to 500ma. Use
can set the graph line color, background color and grid line color.
3.2 GraphLogger
This software can get and display data from all 8 channels of QX-108 board.
User can select reading time in range 100ms to 5000ms. Select the serial port that
interface. After that connect the QX-108 with this software to begin data reading.
When disconnect, all data will be stored in Memo log by clicked right-button
mouse to Save into Text file or select Clear log file to delete data.
DC INPUT
9-12V.
1N4001
7805
+5V
510
0.1/63V
47/25V
47/16V
LED
POWER
+5V
0.1/63V
1
VDD
2
3
4
5
+5V
4k7
Connect to PC
RS-232
4k7
10k
6
RC4
5
RC5
MCLR
14
VDD
AN0
AN1
AN2
AN3
AN4
AN5
AN6
AN7
13
12
11
3
10
9
8
7
+5V
BC547
GND
CH.0
CH.1
CH.2
CH.3
CH.4
CH.5
CH.6
CH.7
+5V
PIC16F676