{0.15b3, Ld}max
{0.15b3, Ld}max
8 (Fe415)- 150
b3
8 (Fe415)- 150
{0.25b3, Ld}max
b2
{0.25b2, Ld}max
staircase
void
{0.25a2, Ld}max
{0.25a2, Ld}max
8 (Fe415)- 150
{0.25b2, Ld}max
{0.15a2, Ld}max
{0.25b1, Ld}max
x
b1
x
8 (Fe415)- 150
8 (Fe415)- 150
{0.25b1, Ld}max
900
{0.25b1, Ld}max
SLAB PLAN
April 2012
16
Figure 7.1 : Slab Reinforcement Details Continued.
Y
a1
a2
a3
A
8 (Fe415)- 150
b3
{0.15b3,Ld}max
8 (Fe415)- 300
8 (Fe415)- 300
b2
staircase
void
{0.3b3,Ld}max
8 (Fe415)- 150
{0.3b2,Ld}max
8 (Fe415)- 300
8 (Fe415)- 300
8 (Fe415)- 150
{0.3b2,Ld}max
{0.3b1,Ld}max
900
{0.15b1,Ld}max
8 (Fe415)- 150
b1
8 (Fe415)- 300
8 (Fe415)- 150
8 (Fe415)- 150
8 (Fe415)- 150
8 (Fe415)- 150
{0.15b3,Ld}max
8 (Fe415)- 300
{0.15b3,Ld}max
{0.15b1,Ld}max
8 (Fe415)- 150
8 (Fe415)- 150
{0.3b1,Ld}max
SLAB PLAN
April 2012
17
Figure 7.1 : Slab Reinforcement Details Continued.
Y
a1
a2
a3
A
8 (Fe415)- 300
8 (Fe415)- 300
8 (Fe415)- 300
b3
8 (Fe415)- 150
8 (Fe415)- 300
8 (Fe415)- 150
{0.15b3,Ld}max
8 (Fe415)- 150
8 (Fe415)- 300
b2
8 (Fe415)- 150
900
b1
staircase
void
8 (Fe415)- 300
{0.15a1,Ld}max
8 (Fe415)- 150
8 (Fe415)- 150
{0.3b2,Ld}max
8 (Fe415)- 300
8 (Fe415)- 150
{0.15b1,Ld}max
{0.3b1,Ld}max
{0.3a2,Ld}max
{0.3a1,Ld}max
8 (Fe415)- 150
8 (Fe415)- 150
8 (Fe415)- 300
{0.3b1,Ld}max
{0.3a3,Ld}max
{0.3a3,Ld}max
{0.3a2,Ld}max
SLAB PLAN
{0.15,Ld}max
{0.3,Ld}max
April 2012
18
Figure 7.1 : Slab Reinforcement Details Continued.
{0.15 a1, Ld} max
8 (Fe415)- 300
Extra top bars
8 (Fe415)- 150
8 (Fe415)- 150
a1
8 (Fe415)- 300
{0.25 a1, Ld} max
8 (Fe415)- 300
Extra top bars
8 (Fe415)- 150
8 (Fe415)- 150
8 (Fe415)- 300
{0.25 a2, Ld} max
a2
8 (Fe415)- 150
8 (Fe415)- 300
Extra top bars
8 (Fe415)- 300
{0.25 a3, Ld} max
C INTERMEDIATE SLAB
END SLAB
8 (Fe415)- 150
a3
125
8 (Fe415)- 150
8 (Fe415)- 300
8 (Fe415)- 150
8 (Fe415)- 300
Extra top bars
8 (Fe415)- 150
b1
INTERMEDIATE SLAB
8 (Fe415)- 300
{0.25 b1, Ld} max
8 (Fe415)- 300
Extra top bars
8 (Fe415)- 150
b2
8 (Fe415)- 150
8 (Fe415)- 300
{0.25 b3, Ld} max
INTERMEDIATE SLAB
200
200
355
125
8 (Fe415)- 300
{0.15 a1, Ld}max
180
230
NBC205V2.RV7
April 2012
8 (Fe415)- 150
b3
END SLAB
180
19
Figure 7.1 : Slab Reinforcement Details Continued.
8 (Fe415)- 300 Extra bars
{0.3 a1, Ld}max
Clear Cover
15 mm
125
8 (Fe415)- 150
8 (Fe415)- 150
Clear Cover
15 mm
8 (Fe415)- 300
8 (Fe415)- 300
8 (Fe415)- 150
Clear Cover
15 mm
180
230
DETAIL AT - B
Notes: For slab, steel grade Fe 500 can also be used without changing bar diameter
8 mm dia Chair resting on Slab formwork
Option-II
8 (Fe415) -150
c/c spacing
Grade of Steel
Diameter of bar
NBC205V2.RV7
April 2012
20
TABLE 7.1: LONGITUDINAL STEEL IN BEAMS
STAIR
COVER
COLUMN
THIRD
STOREY
COLUMN
SECOND
STOREY
COLUMN
INTERMEDIATE BEAM
END BEAM
FIRST
STOREY
COLUMN
Fe 415, fy=20 MPa, Beam design output summary for all Building covered by
this code
Span 3 m
FIRST FLOOR
BEAM / SLAB
355
2-12 TH
3-12 TH
3-12 TH
2-12 TH
2-12 TH
NBC205V2.RV7
230
230
2-12 TH
355
355
2-12 TH
2-12 TH
2-12 TH
2-12 TH
2-12 TH
230
2-12 TH
2-12 TH
2-12 TH
2-12 TH
3-12 TH
2-12 TH
2-12 TH
2-12 TH
230
Foundation
Tie Beam
Plinth Tie
Beam
2-12 TH
2-12 TH
2-12 TH
230
2-12 TH
3-12 TH
2-12 TH
230
2-12 TH
2-12 TH
230
3-12 TH
355
2-12 TH
355
355
2-12 TH
2-12 TH
355
2-12 TH
230
355
2-12 TH
2-12 TH
2-12 TH
355
3-12 TH
2-12 TH
2-12 TH
3-12 TH
3-12 TH
End Beam
Intermediate Beam
3-12 TH
355 355
355
2-12 TH
3.5 m
355
3m Span
355
355
355
355
355
TH
2-12 TH2-12
+1-16 EXT
3-12 TH
2-12 TH
First Floor
Beam
End
2-12Beam
TH
2-12 TH
355
Second Floor
Beam
355
355
355
355
Span 3 m
2-12 THTH
+1-12 EXT
2-12
3-12 TH
355
First Floor
Beam
SECOND FLOOR
BEAM / SLAB
End Beam
Intermediate Beam
2-12 TH
Intermediate
Beam
2-12 TH
3-12 TH
Plinth Tie
Beam
THIRD FLOOR
BEAM / SLAB
Fe2-12415,
fy=202-12MPa,
Beam design
output
TH
2-12 THsummary for all Building covered by
2-12 TH
TH
this code
Foundation
Tie Beam
{
{
{
{
3m Span 3.5 m
End Beam
Intermediate Beam
STAIR COVER
ROOF
2-12 TH
2-12 TH
April 2012
21
TABLE 7.1: LONGITUDINAL STEEL IN BEAMS CONTINUED.
Fe 415, fy=20 MPa, Beam design output summary for all Building covered by
this code
End Beam
2-12 TH
355
2-12 TH
1.
2-12 TH
2-12 TH
2-12 TH
230
230
230
2-12 TH
230
2-12 TH
2-12 TH
2-12 TH
2-12 TH
230
2-12 TH
2-12 TH
230
230
230
2-12 TH
355
355
355
2-12 TH
Plinth Tie
Beam
2-12 TH
Foundation
Tie Beam
3-12 TH
2-12 TH
2-12 TH
2-16 TH stands for 2 number of 16 mm diameter of steel grade Fe415 bar throughout
the beam. 2-16 EXT stands for 2 number of Extra (Additional) 16 mm diameter of steel
grade Fe415 bar at beam end near junction.
2.
Extra top bars coming from adjacent span shall not be curtailed if the span under
consideration is equal to minimum span of 2.1 m.
3.
In case of two adjacent beams of different span, top bars for longer span shall govern.
4.
For Beam detailing with Fe 500 grade steel simply convert area with equation:
415*{area corresponding to Fe 415 Steel} = 500*{area corresponding to Fe 500 Steel}
]
5.
NBC205V2.RV7
2-12 TH
2-12 TH
355
3-12 TH
[Note:
355
355
End Beam
Intermediate Beam
2-12 TH
4.5 m
355
355
355
2-12 TH
First Floor
Beam
4.0 m Span
2-12 TH
355
Second Floor
Beam
Intermediate Beam
4m
355
3.5 m Span
April 2012
22
Transverse Stirrups:
The transverse stirrups are calculated and presented in Table 7.2 for different spans. The
placing of transverse stirrups shall meet the requirements set out in Figure 7.2. The
depth of the foundation shall not be less than 1.2 m.
End Zone,
Special Confining Reinforcement
(up to 2d from face of column )
Fe 415
Fe 500
Roof and
First Floor Second
stair cover
Beam Floor Beam
Beam
Fe 500
8 mm @ 100 mm c/c
8 mm @ 100 mm c/c
8 mm @ 100 mm c/c
Plinth Tie
Beam
Fe 415
8 mm @ 150 mm c/c
Foundation
Tie Beam
Level
8 mm @ 150 mm c/c
Note:
{Ref IS13920; Cl 5.3}
Steel reinforcements of grade Fe 415 (see IS 1786: 1985) or less, shall be used.
However, high strength deformed steel bars, produced by the thermo-mechanical treatment process, of
grade Fe 500, having elongation more than 14.5 percent and conforming to other requirements of IS 1786
: 1985 may also be used for the reinforcement.
NBC205V2.RV7
April 2012
23
Figure 7.2: Beam Details
300
700
325
0.25 L
500
700
300
700
0.25L
0.25L
24. 000
122. 800
24. 000
8 (Fe415)(2L)-100
8 (Fe415)(2L)-150
300 X 300
24. 000
0.25L
700
122. 800
8 (Fe415)(2L)-100
300 X 300
8 (Fe415)(2L)-100
300
700
1
24. 000
24. 000
8 (Fe415)(2L)-100
8 (Fe415)(2L)-150
300 X 300
325
2-12 TH
325
2-12 TH
300
700
Section at 2-2
Middle 1/3 Zone for
top bar lapping
0.25 L
0.25L
700
700
300
0.25L
0.25L
700
300
700
5
500
355
c/c spacing
Nos of Legs
Grade of Steel
Diameter of bar
2-12 TH
Section at 1-1
500
8 (Fe415)(2L)-100
8 (Fe415)(2L)-100
8 (Fe415)(2L)-150
300 X 300
4.0 m<L< 4.5 m
(End Beam)
8 (Fe415)(2L)-100
8 (Fe415)(2L)-100
300 X 300
8 (Fe415)(2L)-150
300 X 300
4.0 m<L< 4.5 m
(Intermadiate Beam)
8 (Fe415)(2L)-100
April 2012
24
Figure 7.2: Beam Details Continued..
2-12 TH +3-12 EXT
2-12 TH
355
355
355
3-12 TH
Section at 3-3
300
3-12 TH
Section at 4-4
0.25 L
c/c spacing
Nos of Legs
Grade of Steel
Diameter of bar
Section at 5-5
700
0.25L
700
300
0.25L
0.25L
700
300
700
8
500
355
500
700
8 (Fe415)(2L)-100
8 (Fe415)(2L)-100
8 (Fe415)(2L)-100
8 (Fe415)(2L)-150
300 X 300
8 (Fe415)(2L)-100
300 X 300
8 (Fe415)(2L)-100
8 (Fe415)(2L)-150
300 X 300
4.0 m<L< 4.5 m
(Intermadiate Beam)
NBC205V2.RV7
8 (Fe415)(2L)-100
c/c spacing
Nos of Legs
Grade of Steel
Diameter of bar
355
2-16 TH
355
355
2-16 TH
Section 6-6
Section 7-7
Section 8-8
April 2012
25
Figure 7.2: Beam Details Continued..
300
230
400
400
600
300
8 (Fe415)(2L)-150
300 X 300
600
300
8 (Fe415)(2L)-150
8 (Fe415)(2L)-150
4.0 m<L< 4.5 m
8 (Fe415)(2L)-150
300 X 300
8 (Fe415)(2L)-150
8 (Fe415)(2L)-150
300 X 300
Note:
The foundation level tie beam is required only in the case when the foundation lies in soft soil.
2-12 TH
230
2-12 TH
or
8 (Fe415)(2L)-100
250
2-12 TH
c/c spacing
Nos of Legs
Grade of Steel
Diameter of bar
2-12 TH
Section at 9-9
75
180
25
25
200
25
250
230
NBC205V2.RV7
125
25
25
25
305
355
125
305
355
25
25
75
25
25
26
General Notes:
Lapping of top and bottom bar is allowed only in the zone shown in Fig 7.3( typical beam detail) .
Not more than 50% of the bars should be spliced at a section.
If longer and smaller apans exists adjacent, top and bottom additional bars of the longer span shall govern.
All Concrete grades are of M20 {1:1.5:3( Cement:Sand:Aggregate)}.
Curtail extra top and bottom bars 0.3L away from support.
The bars extending through adjacent spans to any span equal to 2.1 m shall not be curtailed and stirups be provided same as the ends of the
adjacent beam.
The exposed surfaces of concrete shall be kept continuously water damp for at least one week.
In normal circumstances formwork of slab and beam can be removed after 3 weeks of concreting.
In normal circumstances formwork of column can be removed after 48 hours of concreting.
Lapping of bars should not be less than development length (Ld) and Ld is given as in table below.
TABLE 7.3: Development length of bars for M20 grade of concrete
Diameters of bars, , mm
For Fe 415, Ld = 47, mm
For Fe 500, Ld = 57, mm
NBC205V2.RV7
6
8
280
375
340
455
10
470
570
12
565
685
16
750
910
April 2012
27
Columns
Size and Longitudinal Steel:
Gross sections of column and longitudinal steel are calculated and presented in Table 7.4.
TABLE 7.4: COLUMN SIZES AND LONGITUDINAL STEEL
Fe 415, fy=20 MPa,
Column design output for All buildings covered by
this code
Face Column
Internal Column
300
300
300
300
300
300
300
300
300
300
8-12
300
8-12
300
8-12
4-16 +4-12
8-12
300
300
300
4-16 +4-12
300
300
4-16 +4-12
300
First Storey
Second Storey
Third Storey
Corner Column
4-16 +4-12
4-16 +4-12
Internal Column
300
300
300
300
300
300
300
300
300
300
8-12
300
8-12
300
8-12
8-12
300
300
300
4-16 +4-12
4-16 +4-12
300
8-12
300
8-12
300
First Storey
Second Storey
Third Storey
Corner Column
4-16 +4-12
*The Stair Cover columns detailing are same as that of Third Storey.
NBC205V2.RV7
April 2012
28
[Note:
1. Fe500 TMT bars can only be used if elongation of steel bar is above 14.5%
2. 8-12 stands for 8 numbers of 12 mm steel bars
3. Clear cover for longitudinal bars should be 40 mm]
Transverse Stirrups:
The transverse stirrup ties in all columns shall be:
For Fe415 Steel
Ends of columns for 600 mm length - 08mm @ 100 mm c/c
{Special Confining Reinforcement}
Remaining height
- 08mm @ 150mm c/c
For Fe500 Steel
Ends of columns for 600 mm length - 07mm @ 100mm c/c
Special Confining Reinforcement}
Remaining height
- 07mm @ 150mm c/c
[Note: 1.
2.
3.
NBC205V2.RV7
April 2012
H/4
G. L.
NBC205V2.RV7
8(CT) (Fe415)-150
300 X 300
300 X 300
8(CT) (Fe415)-100
8(CT) (Fe415)-150
8(CT) (Fe415)-150
300 X 300
8(CT) (Fe415)-150
8(CT) (Fe415)-100
600
8(CT) (Fe415)-100
8(CT) (Fe415)-100
600
700
8(CT) (Fe415)-100
300 X 300
8(CT) (Fe415)-150
3
600
8(CT) (Fe415)-150
H/4
8(CT) (Fe415)-100
700
8(CT) (Fe415)-100
2
600
8(CT) (Fe415)-100
8(CT) (Fe415)-100
H/4
8(CT) (Fe415)-150
355
H/4
H/2
ZONE OF MAIN BAR
OVER LAPPING
700
8(CT) (Fe415)-150
600
8(CT) (Fe415)-100
h/4
8(CT) (Fe415)-150
355
h/4
H/2
ZONE OF MAIN BAR
OVER LAPPING
300 X 300
8(CT) (Fe415)-100
8(CT) (Fe415)-150
600
1
600
8(CT) (Fe415)-100
230
H/2
ZONE OF MAIN BAR
OVER LAPPING
29
300 X 300
300 X 300
300 X 300
300 X 300
April 2012
30
Figure 7.3: Column Details Continued..
300
300
300
300
300
8T-12
4-16+4-12
4-16+4-12
Section at 1-1
Section at 2-2
300
Section at 3-3
300
300
H/2
ZONE OF MAIN BAR
OVER LAPPING
300
300
300
300
4-16+4-12
Section at 4-4
300
75
8-12
Section at 5-5
Section at 6-6
40
40
300
40
300
40
220
40
40
220
220
40
300
220
40
300
40
300
220
75
40
40
220
40
75
236
17
300
75
17
236
40
8(CT) (Fe415)-100
c /c spacing
Grade of Steel
Closed Tie
Diameter of bar
NBC205V2.RV7
4-16 (Fe415)
Grade of Steel
Diameter of bar
Nos of bars
April 2012
31
Pad Foundations
Sizes and reinforcement in pad foundations for different soil types and loadings are presented
in Tables 7.5A to 7.5D. All foundations are individual tapering-type pads. Details of
foundations shall be as given in Figure 7.4.
Figure 7.4: Pad Foundations
GROUND LVL.
GROUND LVL.
tm
300
75
200
Ld
PCC (1:3:6)
200 mm Stone Sand
Compaction/ 3" flat brick soling
75
tm
1500
tm
Compaction Earth
See Table
L/B
GROUND LVL.
GROUND LVL.
300
Ld
200
tm+150
100
75
1500
100
Compaction Earth
L/B
75
PCC (1:3:6)
200 mm Stone Sand
Compaction/ 3" flat brick soling
See Table
NBC205V2.RV7
April 2012
32
TABLE 7.5A: PAD FOUNDATION SIZE FOR WEAK SOILS
(Safe bearing capacity = 50 kN/m)
Column
Type
Foundation
Plan
L x B (m)
Maximum
thickness
tm (mm)
Reinforcement
each way
As
Corner
2.2 x 2.2
300
11 - 12
Face
2.4 x 2.4
300
10 - 12
Interior
3.0 x 3.0
400
14 - 12
[Note: 1.
11- 12 Stands for eleven no of 12 mm diameter Fe415 or Fe 500 bars.
Use same dia. bar and same spacing for Fe415 and Fe500 grade steel.]
TABLE 7.5B: PAD FOUNDATION SIZE FOR SOFT SOILS
(Safe bearing capacity = 100 kN/m)
Column
Type
Foundation
Plan
L x B (m)
Maximum
Thickness
tm (mm)
Reinf.
Each Way
As
Corner
1.5 x 1.5
300
7- 12
Face
1.65 x 1.65
300
8- 12
Interior
2.1 x 2.1
400
10- 12
NBC205V2.RV7
Column
Type
Foundation
Plan
LxB
(m)
Maximum
Thickness
tm
(mm)
Reinforcement
Each Way
As
Corner
1.25 x 1.25
300
6- 12
Face
1.4 x 1.4
300
7- 12
Interior
1.7 x 1.7
400
8- 12
April 2012
33
TABLE 7.5D: PAD FOUNDATION SIZE FOR HARD SOILS
(Safe bearing capacity = 200 kN/m)
Column
Type
Foundation
Plan
L x B (m)
Maximum
Thickness
tm (mm)
Corner
1.1 x 1.1
300
5- 12
Face
1.2 x 1.2
300
6- 12
Interior
1.5 x 1.5
400
7- 12
Toe Wall:
All plinth beams shall be constructed on a toe wall [as, fig. 7.5(a),
7.5(b)], or on plinth wall supported by foundation tie beam [as fig. 7.5(c), 7.5(d), 7.5(e)].
230
230
GROUND LEVEL
55 55
Leveling PCC(1:3:6)
Flat Brick Soling with compaction
Earth Compaction
230
55 55
450
150
55 150
1 Brick height
500
250
GROUND LEVEL
375
250
230
230
Leveling PCC(1:3:6)
Stone Soling with compaction
Earth Compaction
500
55 300
112
600
April 2012
2-12 TH
230
34
2-12 TH
PLINTH LVL.
Plinth height
X
PLINTH LVL.
GROUND LVL.
600
1500
75
PCC (1:3:6)
200 mm Stone Sand
Compaction/ 3" flat brick soling
Compaction Earth
PCC (1:3:6)
200 mm Stone Sand
Compaction/ 3" flat brick soling
See Table
L/B
FOOTING SECTION
75
200
Compaction Earth
75
200
75
Compaction Earth
See Table
L/B
FOOTING SECTION
Figure 7.5(c) View of foundation, plinth tie beam, foundation tie beam and toe wall
Plinth wall, lower and upper tie beam option is for Soft and weak soil type as defined in Table 3.1
230
230
2-12 TH
230
230
8 (Fe415)(2L)-150
Through out the length
GL
2-12 TH
50mm.
PCC (1:3:6)
75
200
450
SECTION at X-X
Stair Case:
Staircase should be detailed as in Figure 7.6 given below
Solid wall
25mm Gap between landing
beam and column
up
landing beam
up
Solid wall
Toilet
5'-0"x 5'-3"
Toilet
6'-4"x 5'-3"
D3
Secondary beam
Toilet
5'-0"x 5'-3"
Toilet
D3
6'-4"x 5'-3"
April 2012
35
8 (2L)-100
600
L-2*600
355
300
2-12 TH
Secondary Beam
Y
Main Beam
SECTION AT X-X
230
230
8(2L)-100
600
300
700
8 (2L)-100
8 (2L)-150
2-12 TH
SECONDARY BEAM X/S
8-(2L) -100
700
PLAN
230
700
Ld
Ld
4-12
Ld
Main Beam
Ld
230
355
700
Main Beam
8 (2L)-100
Secondary Beam
Secondary Beam
SECTION AT Y-Y
Figure 7.6(b)Typical Detailing for Connection between Main and Secondary Beams
NBC205V2.RV7
April 2012
36
Landing beam
Wall supporting Landing beam
Regular beam
STORY HEIGHT
Regular beam
Landing beam
Wall supporting Landing beam
Tie beam
Tie beam
To Foundation
To Foundation
230
1360
8 @ 200 c/c
2-12 bars.
275
8 @ each step
167
300
8mm @150mmc/c
12 @ 150 c/c
Regular beam
12 @ 150 c/c
12 @ 150 c/c
2-12 bars.
8 @ 200 c/c
8 @ 200 c/c
1050
8 @ 200 c/c
12 @ 150 c/c
Landing beam230X300,
2-12 top and 2-12 Bottom
bar, STRPS: 8 @ 150 c/c
throughout
12 @ 150 c/c
12 @ 150 c/c
Fig. 7.6(d) OPTION-I:Staircase with RCC waist slab and RCC steps
NBC205V2.RV7
April 2012
37
8 @ 200 c/c
275
12 @ 150 c/c
167
275
0
20
12 @ 150 c/c
20
12 @ 150 c/c
12 @ 150 c/c
167
275
167
8 @ 200 c/c
12 @ 150 c/c
8 @ 200 c/c
DETAIL-A
12 @ 150 c/c
DETAIL-C
DETAIL-B
12 @ 150 c/c
167
275
8 @ 200 c/c
8 @ 200 c/c
1050
12 @ 150 c/c
Regular beam
12 @ 150 c/c
8 @ 200 c/c
12 @ 150 c/c
Landing beam230X300,
2-12 top and 2-12 Bottom
bar, STRPS: 8 @ 150 c/c
throughout
12 @ 150 c/c
12 @ 150 c/c
Fig. 7.6(f) OPTION-II: Staircase with RCC waist slab and Masonry steps
NBC205V2.RV7
April 2012
38
8
8.1
Solid Walls
To prevent walls from falling out, these shall be provided with
horizontal reinforced concrete (RC) bands through the wall at about
one-third and two-thirds of their height above the floor in each storey.
The width of the band should be equal to the wall thickness and its
thickness equal to 75 mm. Reinforcement details shall be as given in
Figure 8.1.
Reinforcement:
8.1.2
(a)
(b)
8.2
NBC205V2.RV7
April 2012
39
t
l/3b
l/3b
l/3b
A
l/3h
450
3.35 m
l/3h
=h B
=
2.8 m
INFILL - WALL
l/3h
ELEVATION
BEAM
SECTION AT A - A
25mm.plaster thickness
COLUMN
100
500
500
100
300
t
300
300
300
SECTIONAL PLAN AT B - B
OPTION-I
25mm.plaster thickness
COLUMN
100
500
500
100
300
300
300
300
SECTIONAL PLAN AT B - B
OPTION-II
t
75
4.75 (1-L)-150
( Fe415 or Fe500)
60
INDEX
4.75 (1L)
60
DETAIL AT A
150
C/C spacing
No. of legs
Diameter of Bars
2-8( Fe415)
NBC205V2.RV7
April 2012
40
t
230
>300
3.35 m
=
h
=
2.8 m
Y
X
ELEVATION
BEAM
25mm.plaster thickness
COLUMN
100
500
500
100
300
300
t
300
SECTION AT A - A
300
SECTIONAL PLAN AT B - B
OPTION-I
INDEX
25mm.plaster thickness
COLUMN
100
4.75 (1L)
500
500
150
C/C spacing
No. of legs
Diameter of Bars
100
300
300
300
300
SECTIONAL PLAN AT B - B
OPTION-II
Door frame
Sill band
t
60
450
60
75
DETAIL AT X
2-8( Fe415)
BEAM
450
DETAIL AT Y
NBC205V2.RV7
April 2012
41
LINTEL BAND
60
75
60
4.75
K (1-L)-150
4.75 (I-L)-1502-8 (Fe475)
2 T 08
B
SILL BAND
ELEVATION
COLUMN
DETAIL AT A
t
500
INSIDE
500
300
OUTSIDE
SECTION AT B - B
500
300
300
DETAIL AT C
NBC205V2.RV7
500
DETAIL AT B
April 2012
42
Z1
Z1
Mortar joint
ELEVATION
SECTION AT Z2 - Z2
Z2
150 mm lap
300
12.5 mm Plaster
12.5 mm Plaster
Z2
SECTIONAL PLAN AT Z1 - Z1
NBC205V2.RV7
April 2012
43
Z3
Z3
2.75 m = h = 3.35 m
230
Y
Mortar joint
12.5 mm Plaster
ELEVATION
Vertical band
450 mm Wide GI
Chicken wire mesh
2 mm GI Anchors
@ 300 c/c Staggered at
each alternate brick course
SECTION AT Z2 - Z2
5 Nos of 75 mm nail
with washer
Z2
Vertical band
450 mm Wide GI Chicken
Detail Y wire mesh
12.5 mm Plaster
12.5 mm Plaster
Detail Z
Vertical band
450 mm Wide GI Chicken wire mesh
100
RC Beam
Horizontal band
450 mm Wide GI
Chicken wire mesh
Half thk Brick Wall
300
150 mm lap
Z2
2 mm GI Anchors
@ 300 c/c Staggered at each
alternate brick course
Vertical band
450 mm Wide GI
Chicken wire mesh
230
SECTIONAL PLAN AT Z3 - Z3
NBC205V2.RV7
April 2012
44
9
Parapets
9.1
General
Parapets above roofs and at the edges of the balconies shall not be taller than
one metre. They should either be constructed in reinforced concrete or be
reinforced with vertical RC elements spaced not more than 1.5 m apart. The
section of the vertical RC post may be kept to b x 75 mm, where b is the
thickness of the parapet. Such RC elements should be reinforced with two
vertical bars of 8 mm diameter steel (grade Fe415)/7 mm Fe 500 with
transverse links 4.75 mm diameter steel (grade Fe415/Fe 500) @ 150 mm
centres. The vertical reinforcement shall be tied in the steel of the slab or
beam below with a minimum embedment of 300 mm. Also, a handrail
should be provided at the top with a section size and reinforcing as explained
in Clause 8.1.1. For details, refer to Figure 9.1.
9.2
Flower Pots
Flower pots should not normally be placed on parapets. However, if it is
desired that they be placed there, they shall be adequately wired and held to
the parapet through pre-fixed steel hooks/anchors so that they will not be
dislodged in severe earthquake shaking.
300
HAND RAIL
300
300
(Fe415)
50
50
Wall thickness
22-8
T 08
K 4.75 (I-L)-150
4.75 (1-L)-150
75
SECTION AT A - A
NBC205V2.RV7
April 2012