Académique Documents
Professionnel Documents
Culture Documents
Jan-May 2010
5- 1
DC Motor
Jan-May 2010
5- 2
DC Motors
Simple control.
Regular maintenance.
Relatively heavy rotor with a high inertia.
Difficulty in producing a totally enclosed motor.
A limit on constant power-speed range because of
commutator electrical and mechanical stress.
Relatively high cost.
High starting current (no back emf present) could
damage commutator and windings.
Jan-May 2010
5- 3
Structure of DC motors
Stator
f produced by
permanent magnets
Jan-May 2010
f produced by
stator winding currents
Electrical Machines & Drives - ECNG 3010
5- 4
N
1
ia
Jan-May 2010
S1
b1
S
f
S2
Bf
b2
5- 5
Structure of DC Motors
Rotor
Jan-May 2010
Armature
winding
Commutator and
brushes
5- 6
Commutator Action
ia
S1
ia
S2
1
S2
+
m
= 0
S1
1
ia
S2
= 0
Tem
S1
+
m
S
= 0
Tem
Jan-May 2010
5- 7
Commutator Action
e1,1,i1tol
0
00
0
00
1800
2700
900
ea(t)
1800
900
2700
Tem
average
1800
0
00
Jan-May 2010
900
Ea
average
Tem(t)
Tem = 2 Bf l ia r
ea = 2 Bf l (rm)
2700
Electrical Machines & Drives - ECNG 3010
5- 8
Commutator Action
Torque and emf pulsations can be reduced by increasing
the number of conductors
ea
4e
Ea
(average)
2e
00 450
Tem
4Tcond
Tem
(average)
2Tcond
00 450
Armature Reaction
Rotor flux
Stator flux
Jan-May 2010
Resultant flux
5- 9
If
If = I a
+
v
Series
Jan-May 2010
+
v
Ia _
_
Shunt
Ia>>If
Ra< Rf
If
+ ef _
Separately
Excited
Ia
+
v
_
5 - 10
if
_
e
+ f
Field winding
Steady
State
f = Kf If
Ef = RfIf = Rf f
Kf
5 - 11
ia
Because of rotation of
conductors (armature) in the
flux field
e.m.f. induced in armature
circuit ( oppose flow of
armature current)
_
Ra La
va
+
eb = KE Steady State Eb = KE
T(t) = KT ia(t) Steady state
P = T = KT Ia Eb
KE
Jan-May 2010
KT
KE
T = KT Ia
Eb I a
5 - 12
5 - 13
Torque-Speed Characteristics
= V Ia Ra
KE
T = KT Kf Ef
RaRf
Jan-May 2010
V Ra T
KE
K2T2
= V2 KTKf
RaRf
Shunt
1 - KEKf
Rf
V - KE Kf Ef
Rf
Separately Excited
5 - 14
DC Motors - Shunt
If
+
v
Ia _
= V Ia Ra
KE
No Load Condition :
T=0 I=0
0 = V/KE
T0 , Ia0 very high
Jan-May 2010
V - Ra T
KE
K2T2
With Load :
= Ra T/(KT)2
= 0 -
5 - 15
DC Motors - Shunt
Ra small small
Characteristic almost constant
T1
If
+ ef _
Jan-May 2010
Ia +
v
_
T
Separately
Excited
Same characteristics
as shunt
5 - 16
Torque-Speed Characteristics
Series
= V - Ia (Ra + Rf )
KE
T=
Jan-May 2010
V
KE Kf Ia
KT K2f V2
[ KE Kf + (Ra + Rf) ]
Ra + Rf
KE Kf
5 - 17
DC Motors - Series
Field Winding
Few turns
High currents
If = I a
+
v
Jan-May 2010
5 - 18
Torque-Speed Characteristics
Jan-May 2010
5 - 19
DC Machine - PM
ia
+
va N
S
+
_
Basic equations :
ea = kTm
va = ea + Ra ia + La dia
dt
Tem = kT ia
dm = 1 (Tem TWL)
dt
Jeq
Jan-May 2010
ia = Tem
kT
va
+
_ea=kE m_
Ra
La
Tem, m
TWL
JL
5 - 20
Brushless DC
Jan-May 2010
ib
+
b
Magnetic
axis of
phase a
5 - 21
Brushless DC
+
utility
Vd
logic
Jan-May 2010
Permanent
magnets
ia
b
+ ea a
5 - 22
Brushless DC
Jan-May 2010
5 - 23