Vous êtes sur la page 1sur 3

SOUTHERN INSPECTION SERVICES

E-Mail: sisins@gmail.com, sisins@hotmail.com


Website: www.sisndt.com / www.ndtsis.com , www.pdmsis.com
: 91-44-24868785, 24864332

Infrared Thermography

3
4
5

S1

S2

S3

S4

10:00 AM 11:15 AM

11:30 AM 01:10 AM

2:00 PM 3:15 PM

Introduction

Radiation Laws

3:30 PM 5:00 PM
Camera Operation
Control & Flow Chart
Explained

Emissivity,
Enhancement,
Determination
Type of
thermography, Target
signature
Building Application,
Analysis
Exam-General

Camera Parameters,
Design, Performance
Reflection Explained,
Ambient temp effects
& Determination

LUNCH BREAK

DAY

Problems in Heat
Flow
Detectors,
Atmosphere
Wind, Cloud

Operating the
Camera

Electrical application,
Calculation, Analysis

Mechanical
Application &
Analysis

Thermographic
report
Exam-Themograms
Analysis

Other Application
Exam-Specific

Discussion
Exam-Camera
Selection

LAB Modules
1. Temperature measurement on blackbodies

21. Oil slick

2. Conduction

22. Pipe line inspection

3. Convection

23. Fuse holder & MCB

4. Moisture indication because of evaporation

24. Fuse holder

5. Ambient temp measurement


6. Telephoto lense & wide angle lense

25. To find the problem in detecting the defective


component in electronic circuit boards

7. Latent image of thermography

26. Transmission lines- loose connection

8. Thermal image absorption by water

27. Transmission line wrong wire

9. Emissivity effect on measurement of


temperature

28. Broken strand- spiral heating

10. Low emissivity lies

30. Broken strand- spiral heating

11. Emissivity measurement

31. To find the overheating of electrical motors

12. Transmissivity

32. To demonstrate the principle of energy


conversion

13. Measurement distance and temperature


measurement

29. Broken PCP track

33. To demonstrate the sterling effect

14. To study effect of the wind speed & how it


affects temperature

34. Micro wave

15. Thump rule method for measuring emissivity

36. Gamma ray

16. Corrosion under insulation

37. UV

17. To find voids & moist areas in bricks

38. IR

18. Geological application

39. Heating by eddy current

19. To find the composite voids

40. Heating by ultrasonic

35. X-ray

20. Thermal capacity explained

No.2, IInd Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.

SOUTHERN INSPECTION SERVICES


E-Mail: sisins@gmail.com, sisins@hotmail.com
Website: www.sisndt.com / www.ndtsis.com , www.pdmsis.com
: 91-44-24868785, 24864332

Course Content
Level I

Level II

The Nature of Heat. What is It? How is It


Measured / Expressed?

Basic Calculations in the Three Modes of Heat


Transfer

Temperature What is It? How is It Measured /


Expressed? Different Temp Scales

The Infrared Spectrum

Radiosity Problems

Heat Transfer Modes Familiarization

Radiation Laws

Radiosity Concepts- Radiation Laws

Emissivity Enigma

Emissivity Explained and Ways To Over Come


Low Emissivity

Techniques to Overcome Low Emissivity

IR Detectors

Background Tem Setting and Ambient


Temperature Explained

IR Instrumentation

Camera Selection Parameter

Checking Equipment Calibration with


Blackbody References

Camera Performance Parameter

Resolution Tests and Calculations

Operating for Infrared Measurements


(Quantification)

Operating for High Speed Data Collection

Types 0f Thermography

Qualitative and Quantitative thermography

Infrared Image and Documentation Quality

Detecting Thermal Anomalies Resulting from


Differences in Thermal Resistance (QuasiSteady-State Heat Flow)

Active, Passive ,Pulsed Phase

IR Application

Themogarhm Analysis

Electrical

Electrical application

Mechanical

Honey Comb Application

Process Industries

Composite Application

Aero Space Industries

Furnace Application

Detecting Thermal / Anomalies Resulting from


Differences in Thermal Capacitance, Using
System of Environmental Heat Cycles

Process Industries Application

Transmission line Loss Application

Detecting Thermal Anomalies Resulting from


Differences in Physical State

Building Application

Mechanical Application

Detecting Thermal Anomalies Resulting from


Fluid Flow Problems

Report Writing and Documentation

Temperature Measurement Applications

Energy Loss Analysis Applications

Active Applications

Filtered Applications

Transient Applications

No.2, IInd Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.

SOUTHERN INSPECTION SERVICES


E-Mail: sisins@gmail.com, sisins@hotmail.com
Website: www.sisndt.com / www.ndtsis.com , www.pdmsis.com
: 91-44-24868785, 24864332

AMERICAN SOCIETY FOR NONDESTRUCTIVE TESTING AS PER SNT-TC-1A-2006

NDT LEVEL I & II COURSE DETAILS


Sl.
No.

Subject

Duration of
course

Course fee
(amount in rs.)

5 days

40,000.00

1.

Infrared Thermography Testing

2.

Vibration Analysis

5 days

40,000.00

3.

Acoustic Emission Testing

8 days

40,000.00

4.

API 510 (Pressure Vessel Inspector)

5 days

30,000.00

5.

API 570 (Piping Inspector)

5 days

30,000.00

6.

API 653 (Above Ground Storage Tank Inspector)

5 days

30,000.00

7.

API 579 ( Fitness For Services)

5 days

30,000.00

8.

API 936 (Refractory)

5 days

30,000.00

9.

API 576 (Inspection of Pressure Relieving Devices)

3 days

15,000.00

10.

API 577 (Supplemental Certification Welding & Metallurgy)

3 days

15,000.00

11.

API 580 ( Supplemental Certification Risk Based


Inspection)

3 days

15,000.00

12.

API 571 (Supplemental Certification corrosion & Materials)

3 days

15,000.00

13.

API 577 (Supplemental Certification Welding & Metallurgy)

3 days

15,000.00

14.

Leak Testing

5 days

15,000.00

15.

Concrete Testing

5 days

25,000.00

16.

Penetrant Testing

1 day

4,000.00

17.

Magnetic Particle Testing

2 days

4,000.00

18.

Radiographic Testing

5 days

6,000.00

19.

Ultrasonic Testing

5 days

6,000.00

20.

Visual Testing

2 days

4,000.00

21.

Eddy Current Testing

5 days

15,000.00

22.

Neutron Radiography Testing

8 days

20,000.00

23.

Ultrasound Analysis

6 days

30,000.00

24.

Predictive Maintenance (PDM)

5 days

25,000.00

25.

Motor Signature Analysis

6 days

30,000.00

26.

Concrete Testing (Ultrasonic)

1 day

6,000.00

27.

Radiographic Film Interpretation

2 days

5,000.00

28.

Composite NDT Training & Testing

5 days

25,000.00

29.

Magnetic Flux leakage

5 days

20,000.00

No.2, IInd Floor, Govindaraji Naickar Complex, Janaki Nagar, Arcot Road, Valasaravakkam, Chennai 600087. Tamilnadu. India.

Vous aimerez peut-être aussi