Académique Documents
Professionnel Documents
Culture Documents
Post-installed rebar
Injectable mortar and everything required for the safe installation of concrete-to-concrete connections.
Ventilated facade
Firestop
Installation systems
Solutions for pipe and cable penetrations through floors or walls, and for
fire rated joint seals to reduce post
earthquake impacts.
Structure detection
A team of qualified and experienced engineers is available to provide you with more
detailed information and to help you determine and design the best solution for your
particular project. Contact them by phone at 01 30 12 65 01 (from 8h30 to
12h30 and from 13h30 to 17h00), by fax at 01 30 12 52 40 or by e-mail at
fr-servicetechnique@hilti.com
Hilti = registered trademark of Hilti Corp., Schaan | 2015 | Right of technical and programme changes reserved S. E. & O.
7
9
10
Equipments
www.hilti.fr/le-risque-sismique
8
7
4
5&EXLOGLQJDYHUDJH
10
6WUXFW
1RQVW
&RQWH
5&EXLOGLQJDYHUDJH
2IILFH
6WUXFWXUDO
1RQVWUXFWXUDO
&RQWHQWV
5&EXLOGLQJDYHUDJH
+RWHO
1RQVWUXFWXUDO
&RQWHQWV
20%
40%
20%
18%
5&EXLOGLQJDYHUDJH
8%
+RWHO
44%
2IILFH
40%
Structural
17% 13%
48%
+RVSLWDO Nonstructural
Contents
70%
62%
6WUXFWXUDO
Average Concrete Building
Office
Hotel
Hospital
1RQVWUXFWXUDO
Source: Taghavi S. and Miranda E.: Seismic Performance and Loss Assessment of Nonstructural Building Components,
Proceedings of 7th National Conference on Earthquake Engineering,
Boston,
2002.
+RWHO
&RQWHQWV
+RVSLWDO
New rating classifications for anchor performance under seismic load: C1 and C2
New European testing procedure for determining the seismic suitability of fastenings
The seismic pre-qualification of anchors has been regulated since early 2013 in Europe
following the release of ETAG 001 Annex E. Anchors subject to this new test procedure must
now incorporate in the ETA all the required seismic design technical data . The suitability for
seismic loading is classified as:
ETA seismic category C1 similar to U.S. pre-qualification procedure; only suitable for nonstructural applications according to the EOTA TR045 recommendations
ETA seismic category C2 arduous seismic crack movement tests qualify an anchor as
suitable for more demanding structural and non-structural applications
Structural applications
Acceleration (ag.S)
< 0.05g
0.05g to 0.1g
> 0.1g
Non-structural applications
Building importance
II, III, IV
non-seismic
ETA C2
Acceleration (ag.S)
Building importance
II, III
< 0.05g
Building importance
IV
non-seismic
0.05g to 0.1g
ETA C1
> 0.1g
ETA C2
ETA C2
The map above is based on national earthquake data (for ordinary buildings and ground type A) and provides perspective on the
relevance of the new ETA guidelines in various countries. For more precise information see national regulations.
Page 4 I Edition march 2015
www.hilti.fr/le-risque-sismique
M10
M12
M16
M20
C1
C1
C1
C1
C1
C2
C2
C1
C1
C1
C2
C2
C2
C1
C1
C1
C1
C2
C2
C2
C2
M24
M30
ETA 12/0006
15/03/2013
ETA 98/0001
08/05/2013
ETA 99/0009
06/01/2015
ETA 11/0493
20/06/2013
C1
C1
C1
C1
C1
C1
C1
ETA 07/0260
16/05/2013
C1
C1
C1
C1
C1
C1
C1
ETA 13/1038
13/01/2015
ETA 08/0307
29/04/2014
C1 *
C1 *
C1 *
Design tools
Design is further simplified by Hiltis own PROFIS software, which allows users to
design fastening systems and rebar connections easily and in accordance with
the state-of-the art seismic code framework.
Additionally, the printed version of the Fastening Technical Manual (FTM) provides
all technical data for both anchoring and rebar connections.
PROFIS Anchor
Page 6 I Edition march 2015
FTM
www.hilti.fr/le-risque-sismique
Hilti X-BT
designed to create a weld to the base material for an
extremely strong hold and high loading capacity
PROFIS Rebar
FTM
Cable penetration
Pipe penetration
Joints
www.hilti.fr/le-risque-sismique
Test setup
Three tests are defined:
Required displacement
Parallelogram test: This test is performed to observe the behaviour of the system to follow the
movement of the building on which it is fixed. The ventilated facade is installed on a rigid frame
(3 000 x 3 000 mm) fixed on the bottom. The support is gradually deformed in its plane (parallelogram)
by a static displacement applied at the head according to the cycles predefined.
The maximum displacement is 60 mm.
A visual control is done on fall elements, breakage or deformation of a component system.
Parallelogram test
Required displacement
Gliders
Dynamic test
Dynamic test: This test is to observe the behavior of the system when the support on which it is
mounted is moving in its plane under the action a cyclic reciprocating motion imposed. The ventilated
facade is installed on a rigid frame (3 000 x 3 000 mm) on gliders. Cycles of movements are applied
around the frequency of the system. The maximum displacement is 60 mm. A visual control is done
on fall elements, breakage or deformation of a component system.
Dynamic perpendicular test: This test is the same as the dynamci test with movement perpendilar to its
plane
Brackets
Profiles
Bracket MFT-MFI M
For sliding point
L Profile
In Aluminium, thickness 2,0 mm and 2,5 mm
Bracket MFT-MFI L
For fixed point
T Profile
In Aluminium, thickness 2,0 mm and 2,5 mm
Pipes
For pipes installation, the basic principle is that the fastenings have to be designed so that the horizontal seismic loads can be
taken in addition to the gravity forces.
To take horizontal forces, the pipe fastenings must either be designed to be sufficiently flexurally stiff, or have bracing that can transfer the
horizontal forces (Fh). It must be ensured that horizontal loads can be taken transversely and longitudinally in relation to the pipe axis.
Threaded rods
Channels
Hinge MQS-AB
For bracing of threated rod to base material
Hinge MQS-H
For connecting two threaded rods
Hinge MQS-AC
For bracing of channel to base material or to angle
Exist in renforced version MQS-ACD
Angle MQS-W
For connecting two channels
Can be installed on MQ 41, MQ 72, MQ 41 D
www.hilti.fr/le-risque-sismique
Seismic bracing
Braces for a earthquake-resistant installation need to be arranged at a distance (b) from each other that must be assessed in relation to
seismic acceleration, the mass of the pipes or (system in general) and the type of braces itself - i.e. the situation of the seismic brace
respect to the main axis of the pipe. For this reason, we can distinguish three basic types of seismic-resistant media:
Longitudinal bracing: seismic brace arranged longitudinally to the main direction of the plant - resistance to horizontal actions acting
along the main axis of the pipe
Transversal bracing: seismic brace perpendicular to the main direction of the plant - resistance to horizontal actions acting transversely
of the pipe
4-way bracing: structure composed of both longitudinal and transversal braces, therefore able to withstand all of the forces acting on
the horizontal plane.
It is advantageous for the bracing to be at a spacing that is a multiple of the normal pipe fastening spacing of (s), so that, for example,
every third or fourth pipe fastening is braced.
Single pipe application
Transversal bracing
Design tools
Design is further simplified by Hilti PROFIS Installation,
which helps users to design installation systems easily and in
accordance with the state-of-the art code.
Additionally, the Installation systems catalogue provides all
technical data for all products MM, MQ and MI.
Download the latest version of Hilti PROFIS Installation and the
technical data sheets from www.hilti.com.
Manuel technique
Systme de
supportage
Hilti France I 1 rue Jean Mermoz I 78778 Magny les Hameaux I T +33 1 30 12 50 00 I F + 33 1 30 12 50 12 I www.hilti.fr
02/2014 I Hilti = marque dpose du Groupe Hilti. Photos et textes non contractuels, sous rserve derreur typographique I MK homologation I Ref 2038 I 4 000 ex.
PROFIS Installation
Catalogue