Vous êtes sur la page 1sur 1

Inductive Gauging Sensors

Accurate analogue output of minute displacement

Inductive Gauging
Sensors
EX-200 Series
Refer to P.789 for a list of products
complying with EU Directives.

EX-200

Inductive Gauging Sensors

The EX-200 Series measures target displacement with a resolution


of 0.04% F.S. (0.4 m with the EX-305 sensor head). The dual
analogue outputs (voltage/current) enable connection to external
equipment.

Lineup
Model

Type

Measuring
range

Appearance

Sensor head

Controller

Cylindrical

EX-305

EX-201

5.4 x 18 mm

Threaded

EX-110

EX-202

M10 x 18 mm

EX-416

EX-205

14.5 x 20 mm

EX-422

EX-210

22 x 35 mm

Resolution

Mounting
size

0.4 m

5.4 mm

0.8 m

M10

2 m

M16

4 m

M12

0 to 1 mm

0 to 2 mm

Linearity of 1% of F.S.
Using the built-in lineariser circuit, the EX-200 Series accurately
outputs absolute displacement values.

0 to 5 mm

Cylindrical/
Threaded
0 to 10 mm

High response speed


The EX-200 Series offers a response frequency of up to 18 kHz (with
the EX-305), allowing measurement of rapidly vibrating targets.

Specifications
Type
Sensor head

Model

Controller

Measuring range

Analogue output

Cylindrical

Threaded

5.4

M10

14.5/M16

22/M12

EX-305

EX-110

EX-416

EX-422

Cylindrical/Threaded

EX-201

EX-202

EX-205

EX-210

0 to 1 mm

0 to 2 mm

0 to 5 mm

0 to 10 mm

Output voltage

0 to 5 V (Output impedance 100 )

Output current

4 to 20 mA (Applicable load: 0 to 350 )

Resolution

0.04% of F.S. (Response frequency: LOW)

Linearity
Response
frequency

Fibreoptic
Sensors

18 kHz (-3 dB)

15 kHz (-3 dB)

13 kHz (-3 dB)

LOW

1.3 kHz (-3 dB)


NPN: 100 mA (40 V) max., Residual voltage: 1 V max. (N.C.)

Functions

Auto-zero function/Respons e frequency selecting function


Sensor head 1.

0.03% of F.S./C

Controller 1.

0.04% of F.S./C

Power supply voltage

Safety/
Area Sensors
Pressure
Sensors

240 mA max.
Sensor head

-10 to +60C, No freezing

Controller

0 to +50C

Relative humidity

Measurement
Sensors

35 to 85%, No condensation

Enclosure rating

Sensor head: IP67


Sensor head

Weight

Proximity
Sensors

12 to 24 VDC 10%

Current consumption
Ambient temperature

Photoelectric
Sensors

8 kHz (-3 dB)

Disconnection alarm output 2.

Temperature
fluctuation

New Products

1% of F.S.
HIGH

GT
LK
IL
IA
LJ
LT
LS
TM
IG
IB
FW
EX
GA
RD

MEASUREMENT SENSORS

EX-200

Approx. 45 g

Approx. 55 g

Approx. 75 g

Controller

Approx. 200 g

PLCs/
Touch Panels

Approx. 285 g

The above data was obtained using a steel target (S45C, SS41, t=1 mm).
When measuring aluminium, copper, or stainless steel targets, refer to the linear characteristics for these materials.
1. When the distance between the sensor head and the target is within 50% of the measuring range.
2. NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP output converter.

Servo
Systems
Static
Eliminators

Dimensions

Unit: mm

Controllers

Sensor heads

EX-201/202/
205/210

EX-305

18

18

Code
Readers

3000

Digital
Microscope

3.2

M10, P=1

0 to 180

Marking
Equipment

3.2

EX-110

112

3000

5.4

Vision
Systems

Across-flats:14, t=3

Optical
Comparator

4-5
mounting hole

EX-416

14

3000

14.5
3.2

M16, P=1
112

99

35.4

90

FREE DOWNLOAD

EX-422

www.keyence.com.sg/GQR
Free downloads for product and technical support are readily
available in one convenient location

454

Across-flats: 21, t=4

20

15

3000

22
40

60

TECHNICAL GUIDE: P.742

2.5

65
CAD DATA Download:

www.keyence.com.sg/CADG

Across-flats: 19, t=3.5

M12, P=1

www.keyence.com.sg

5.4

455

Vous aimerez peut-être aussi