Vous êtes sur la page 1sur 4

GuardPLC 1200, GuardPLC 1600, GuardPLC 1800 and GuardPLC 2000 Processor Hard...

ID

37128
Products
Safety Products
Guard PLC

GuardLogix (1756)
RSLogix Guard Plus
Category (optional)

General

Date Created

11/20/2006

Page 1 of 4

GuardPLC 1200, GuardPLC 1600, GuardPLC 1800 And GuardPLC


2000 Processor Hardware & Firmware Revision History &
GuardPLC Software Compatibility
Question
GuardPLC 1200, GuardPLC 1600, GuardPLC 1800 and GuardPLC 2000 Processor

Hardware & Firmware Revision History & GuardPLC Software Compatibility


Answer
GuardPLC 1200, GuardPLC 1600, GuardPLC 1800 and GuardPLC 2000 Processor
Hardware & Firmware Revision History & GuardPLC Software Compatibility

Last Updated

11/20/2006
Access Level

Everyone

Prev. TN#

G44849592

ModelCatalog NumberCPU Hardware Version Description


(label on circuit board)
Guard 1200 PLC 1754-L28BBB Unknown
Guard 2000 PLC 1755-L1 V.00 Beta?
V.01 Original Release
Processor Firmware Version History
Firmware released with RSLogixGuard PLUS!
Programming Software

GuardPLC Platform

Comment / New Functionality

GuardPLC 1200 & 2000:




Series A CPU FW
1.04 [1200]

Series A CPU FW
1.04 [2000]

Initial Release

Series A COM FW
1.00 [1200]

RSLogixGuard
Project Mgr 3.3 Build 4903
Hardware Mgr 2.2.12

Series A COM FW
1.00 [2000]

GuardPLC 1200 & 2000:




Series B CPU FW
2.04 [1200]

Series B CPU FW
2.04 [2000]

Add peer to peer


communications.

Series B COM FW
2.80 [1200]

Series B COM FW
2.80 [2000]

GuardPLC 1200 & 2000:




Series C CPU FW
4.32 [1200]

Add support for Safety Ethernet


Distributed
I/O modules (all platforms).

Series C CPU FW
4.32 [2000]

http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.cfg/php/enduser/prnt... 14/03/2007

GuardPLC 1200, GuardPLC 1600, GuardPLC 1800 and GuardPLC 2000 Processor Hard...

Page 2 of 4

Series C COM
FW 4.24 [1200]

Series C COM
FW 4.24 [2000]

GuardPLC 1600/1800:
RSLogixGuard PLUS!
Project Mgr 3.5 Build 6817
Hardware Mgr 4.0.26

Series A CPU FW
4.32

Add GPLC 1600/1800 platforms.

Series A COM FW
5.14

GuardPLC DIO:


FW 4.28

GuardPLC 1200 & 2000:




Series C CPU FW
6.12 [1200]

Series C CPU FW
6.12 [2000]

Updated to stay consistent with


GPLC 1600/1800

Series C COM
FW 8.32 [1200]

RSLogixGuard PLUS!
Project Mgr 4.0 Build 6104
Hardware Mgr 6.56.0

Series C COM
FW 8.32 [2000]

Guard PLC 1600/1800:

Series B CPU FW
6.12

Add DeviceNet Safety Scanner


functionality (GPLC 1600/1800
only).

Series B COM FW
8.32

GuardPLC DIO:


FW 6.12

GuardPLC 1200/2000:


Series C CPU FW
6.28 [1200]

Series C CPU FW
6.28 [2000]

RSLogixGuard PLUS! Project


Mgr 4.1 Build 6111 Hardware
Mgr 7.56.10

Add support for 4 new


Distributed I/O modules and HHT
(all platforms)

Series C COM
FW 8.32 [1200]

Series C COM
FW 8.32 [2000]

GuardPLC 1600/1800:


Series C CPU FW Add EtherNet/IP communications


functionality. (GPLC 1600/1800
6.28
only)
Series C COM
FW 10.36
GuardPLC DIO

http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.cfg/php/enduser/prnt... 14/03/2007

GuardPLC 1200, GuardPLC 1600, GuardPLC 1800 and GuardPLC 2000 Processor Hard...

FW 6.28

Page 3 of 4

Table 1 - Firmware released with RSLogixGuard PLUS!


Note:
When using version 1.04 firmware in the controller and a project is created, the code generation
version (RSLogix Guard Configuration Control Center Controller Properties) must be set to "1" or
the project will not compile/run in the controller.
When using version 2.04 firmware in the controller, the code generation version (RSLogix Guard
Configuration Control Center Controller Properties) must be set to "2" regardless of whether or
not the project is utilizing peer-to-peer communication.

The combination of RSLogix Guard PLUS, GuardPLC firmware, and DIO firmware according to
table 1 is the best choice.
When other combinations are used, you will not have access to certain functional upgrades.
Detailed Version Compatibility
CPU/COM (platform)

DIO

RSLogixGuard PLUS!
Version

Compatible?

1.04 / 1.00 (1200/2000)

N/A

3.3 (RSLogix Guard)

Yes

2.04 / 2.80 (1200/2000)

N/A

3.3 (RSLogix Guard)

Yes

1.04 / 1.00 (1200/2000)

N/A

3.5 and above

No

2.04 / 2.80 (1200/2000)

N/A

3.5 and above

No

4.32 / 4.24 (1200/2000)

4.28

3.5 and above

Yes

4.32 / 5.14 (1600/1800)

4.28

3.5 and above

Yes

4.32 / 4.24 (1200/2000)

6.12 & above

3.5 and above

No

4.32 / 5.14 (1600/1800)

6.12 & above

3.5 and above

No

6.12 / 8.32 (all 4 platforms)

4.28

3.5 and above

Yes *

6.12 / 8.32 (all 4 platforms)

6.12

3.5 and above

Yes *

6.12 / 8.32 (all 4 platforms)

6.28

3.5 and above

Yes

6.28 / 8.32 (all 4 platforms)

4.28

3.5 and above

Yes*

6.28 / 8.32 (all 4 platforms)

6.12

3.5 and above

Yes*

6.28 / 8.32 (all 4 platforms)

6.28

3.5 and above

Yes

6.28 / 10.36 (1600/1800)

6.12

3.5 and above

Yes*

6.28 / 10.36 (1600/1800)

6.28

3.5 and above

Yes

+
+

Update for CPU firmware to 6.28 is recommended

Update of the DIO firmware to 6.28 is recommended

Table 2 - Detailed Version Compatibility

DISCLAIMER
This knowledge base web site is intended to provide general technical information on a particular
subject or subjects and is not an exhaustive treatment of such subjects. Accordingly, the
information in this web site is not intended to constitute application, design, software or other
professional engineering advice or services. Before making any decision or taking any action,
which might affect your equipment, you should consult a qualified professional advisor.

http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.cfg/php/enduser/prnt... 14/03/2007

GuardPLC 1200, GuardPLC 1600, GuardPLC 1800 and GuardPLC 2000 Processor Hard...

Page 4 of 4

ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR


ACCURACY OF ANY OF THE DATA CONTAINED IN THIS WEB SITE AND MAY MAKE
CHANGES THERETO AT ANY TIME IN ITS SOLE DISCRETION WITHOUT NOTICE.
FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS "AS IS." IN
NO EVENT SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING
DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT OR DAMAGE, EVEN IF
ROCKWELL AUTOMATION HAVE BEEN ADVISED ON THE POSSIBILITY OF SUCH
DAMAGES.
ROCKWELL AUTOMATION DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR
IMPLIED IN RESPECT OF THE INFORMATION (INCLUDING SOFTWARE) PROVIDED
HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do
not countenance the exclusion of implied warranties; thus, this disclaimer may not apply to you.

Copyright 2006 Rockwell Automation. All rights reserved.

http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.cfg/php/enduser/prnt... 14/03/2007