Huawei Energy Powering the Future

Huawei Data Center Facilities Solutions

Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademark Notice
, HUAWEI, and

are trademarks or registered trademarks of Huawei Technologies Co., Ltd.

Other trademarks, product, service and company names mentioned are the property of their respective owners.
General Disclaimer
The information in this document may contain predictive statements including,
without limitation, statements regarding the future financial and operating results,
future product portfolio, new technology, etc. There are a number of factors
that could cause actual results and developments to differ materially from those
expressed or implied in the predictive statements. Therefore, such information

HUAWEI TECHNOLOGIES CO., LTD.


Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
Version No.: M3-022333-20131226-C-1.0

is provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice.

_ 6 -(20140911).indd 2-3

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

2014/9/11 13:53:07

ith the rapid development of cloud computing


and mobile Internet businesses, the growth of IT
density and energy consumption are bringing a lot

of challenges to the traditional data center. Traditional data centers

o comply with the requirements of cloud computing and virtualization


in future, as well as improving the efficiency of data centers and
reducing the TCO, HUAWEI has launched the data center facilities

solution. It is a new generation data center solution with complete integration

are suffering from long construction periods, low efficiency, high

of rack cabinets, power supply and distribution systems, cooling systems, cabling

TCO and inefficient management.

systems, management software, and much more. HUAWEI data center facilities
solution can help customers win in the Cloud era through fast deployment,
flexible expansion, high efficiency & reliablility and intelligent management.

_ 6 -(20140911).indd 4-5

2014/9/11 13:53:09

Contents
Container Data Center  01
Modular Data Center  05
Intelligent Management System  11
Global Applications 13

IDS2000

IDS2000(Single-Row)

IDS1000
IDS2000(Dual-Row)

IDS1000-C

IDS1000-A

_ 6 -(20140911).indd 6-7

2014/9/11 13:53:14

Container Data Center


IDS1000-A All-in-one container data center
Introduction

Specifications

The All-in-One container data center solution functions as a foundation


for cloud computing in enterprise data centers. It meets the requirements
of telecom operators and Internet service providers for environmental
protection, energy conservation, and fast deployment. In addition, it has
distinct advantages in scenarios such as disaster relief operations, military
operations, oil exploration, and enterprise data management.

Application Scenarios

Emergency Air Conditioner


Light
Indoor Unit

IDS1000-AM

Air Conditioner
Outdoor Unit

Air Conditioner
Indoor Unit

IT Rack

IT Rack

Tools
Rack

UPS
Rack

IT
Cabinet

Battery
Apartment

UPS
Cabinet

Tools
Cabinet

Gas
Tank

Gas Tank PDB


Air Conditioner
Outdoot Unit

Air Conditioner
Indoor Unit

Battery
Cabinet

PDB

IT load48kW per container


Fast deployment and movable scenarios

IDS1000-AM

IDS1000-AS

Value & Features


Sub Feature
Easy
Prefabricated and pre-tested
Highly integrated, one container is an entire data center
Easy on-site work, saving 80% deployment time
Efficient
High energy efficiency, PUE down to 1.5
High efficiency O&M, saving 30% OPEX
Reliable
High environment adaption helps business operate stably
IP56 external protection level and 9 intensity anti-seismic level

Power

IDS1000-AS

Cooling

Environmental
requirements
Fire control

Size

IDS1000-AM

IDS1000-AS

Input power

Two mains or one main power plus one generator

Lightningproof level

Class B, 60kA(PDB)

Power density per rack

6kW per rack

UPS mode

HUAWEI UPS 2000G, 20kVA rack mounted UPS

UPS redundancy

3+1 redundancy

2+1 redundancy

BAT backup time

7~10 mins

10 mins

Technology

DX (Direct Expansion) type air-conditioner units

Containment

Hot and cold aisle isolation

Cooling capacity

20kW per unit, 3+1 redundancy

Refrigerant

R410A

Humidity

Build-in humidification function

Operation temperature

-40C ~ +55C*

Operation humidity

10% to 90% relative humidity

Altitude

<3000m

Type

Automatic fire detection & suppression system c/w emergency release function

Dimensions(L*W*H)

12192*2438*2896(mm)

6058*2438*2896(mm)

Total IT load

48kW

24kW

Typical rack capacity

8 IT racks, 360U

4 racks, 180U

20kW per unit, 2+1 redundancy

* +52C ~ +55C tropical conditions should use high temperature air conditioner, -40C ~ -15C conditions should use low temperature air conditioner,
some parameters will change.

_ 6 -(20140911).indd 1-2

2014/9/11 13:53:26

Container Data Center


IDS1000-C cluster container data center
Introduction

Specifications

Traditional data centers suffer from long construction periods, high energy
consumption and high initial investment. To help resolve these issues,
HUAWEI has launched the IDS1000-C outdoor data center solution, which
has a highly integrated power system, environmental monitoring, cooling
systems, racks, cabling, fire control, security and other infrastructure facilities.

IT Equipment container
Fire Control
Monitoring Modules

Fire
Extinguisher

Power container (20ft)


Hydrogen
alarm controller

Fire
Control Tank

Emergency
lamp

Audible and
visual alarm

VESDA

LCU
UPS5000-E

Functional
cabinet

UPS
Cabinet

Hydrogen sensor
Hydrogen
emission fan

This solution complies with the diverse business needs of customers today.

Access
controller

Application Scenarios
IT load270kW
Fast deployment, staged deployment scenario

Three-Cabinet
LCU

IDS1000-C

Three-Cabinet
LCU

LCU

LCU

LCU

LCU

PDF

Cooling container

BCB-BOX

FM200 Fire
Extinguisher

Power
distribution box

Central control container


Switch

Screen

Fire Control Box

Value & Features


Water Chiller

Easy
Prefabricated and pre-tested, ensure deploy time is one week
Modular structure realizes fast & on-demand deployment
Intelligent management makes unattended operation
Efficient
High energy efficiency, PUE down to 1.2
High density and saving 80% footprint

Battery

Water Chiller

Expansion Tank

Water Chiller

Water Chiller PDF


AC

Code Storage Box

Component

IDS1000-C
Power

Reliable
Component/device/system triple reliable design
IP56 external protection level and 9 intensity anti-seismic level.
Operate without interrupted from -40C to +55C
CoolingChilled water

Design operation
Parameters

Size

Access Controller

Entry Door

Features
Input power

Two mains or one main power plus one generator

Power density per rack

3kW~15kW

UPS capacity

40kVA~320kVA

UPS redundancy

2N or N+X

Battery backup time

10mins

Technology

Outdoor unit: Four 100kW chillers for 3+1 backup


Indoor unit: twelve 30kW units for 9+3 backup

Containment

Hot and cold aisle isolation

Total cooling capacity

300kW

Indoor unit capacity

20kW

Indoor unit size

300mm(W)1000mm(D)2100mm(H)

Refrigerant

R410A or R134a

Fan type

EC Fans

Compressor

Scroll compressor

Humidity control

20%~80%

Temperature

-40C ~ +55C*

Relative humidity

10%~100%

IT container

12,192mm*2438mm*2896mm (L*W*H)

Cooling container

12,192mm*2438mm*2896mm(L*W*H)

Power container

6,058mm*2438mm*2896mm(L*W*H)

Rack

45U, 18 PCS

* +45C ~ +55C tropical conditions should use high temperature air conditioner, -40C ~ -15C conditions should use low temperature air conditioner,
some parameters will change.

_ 6 -(20140911).indd 3-4

2014/9/11 13:53:29

Modular Data Center


IDS2000 modular data center
Introduction

Specifications

HUAWEI IDS2000 is a new generation modular data center solution with


complete integration of cabinets, power supply and distribution systems,
cooling systems, cabling systems, management software, and much more.
It supports flexible deployment with single or dual row, cold or hot aisle
containment. The maximal IT power can be up to 21kW/rack.

Application Scenarios

Item

IDS2000(Dual-Row)

System

Single module is applied to small or medium data center (total IT


load200kW, area100m2)
Multiple modules can be used to construct a large data center to
meet large enterprise data center requirements, such as government,
education, healthcare, finance, telecom industries data center and etc.

Value & Features


Cabinet

Easy
Standardized devices, modular architecture, on-demand deployment
Intelligent module-level management , easy O&M
Efficient
Closely coupled cooling, efficient power system, module-level PUE
down to 1.06
Aisle containment, separated hot and cold air, eliminating hot spots
Reliable
Component/device/system tri-level reliability design, ensuring 99.999%
availability
Excellent environment adaptability, stable operations under extreme
conditions

IDS2000(Single-Row)

Air-cooled In-row Air


Conditioner

Chilled water In-row


Air Conditioner

Rack-mounted UPS

Modular UPS

_ 6 -(20140911).indd 5-6

Specifications

Dimensions

300mm single-row with aisle containment:


L x 1560mm x 2180mm, L10800mm
1200mm single-row with aisle containment:
L x 2400mm x 2350mm, L10800mm
Dual-row with aisle containment:
L x 3600mm x 2350mm, L14400mm

Number of IT racks per module

Single row: 12; dual row 36

Input Power

208/220V (3Ph, 60Hz)


380/400/415V (3Ph, 50/60Hz)
440/460/480V (3Ph, 60Hz)

IT power consumption per module

200kVA

Maximum power per rack

21kW

Operating condition

T1 condition: 30C ~ +45C; T3 condition: 20C ~ +55C

Reliability level

Tier II or Tier III (up to Tier IV)

Altitude

0~1000m (derating above 1000m)

Installation

Installing on concrete floor or raised floor

Dimensions(H x W x D)

2000mm x 600mm x 1200mm , 2200mm x 600mm x 1200mm

Installation space

42U/47U

Protection level

IP20

Cooling capacity

20kW/25kW/35kW

Dimensions(H x W x D)

2000mm x 300mm x 1200mm, 2000mm x 600mm x 1200mm

Input power

380/400/415V (3Ph, 50/60Hz), 440/460/480V (3Ph, 60Hz)

Refrigerant

R410A

Cooling capacity

30kW

Dimensions(H x W x D)

2000mm x 300mm x 1200mm

Input power

200 ~ 240V (1Ph, 50/60Hz)

Refrigerant

Water / Ethylene Glycol

Input power

380V (3Ph, 50/60Hz)

Rated capacity

10/15/20kVA

Input power

380V (3Ph, 50/60Hz)

Rated capacity

40~800kVA

2014/9/11 13:53:29

Specifications

Specifications

IDS2000 Typical Products 20kVA

IDS2000 Typical Products 30kVA

PDU 8000

Storage
battery

IT cabinet IT cabinet

Storage
battery

In-Row air
conditioner

IT cabinet

Contained cold aisle

End door

PDU 8000

Storage
battery

Storage
battery

In-Row air
conditioner

In-Row air
conditioner IT cabinet

IT cabinet

IT cabinet

PDU 8000

End door

Cable
distribution
frame

IT cabinet

Cable
In-Row air
distribution
conditioner IT cabinet
frame

Contained cold aisle

PDU 8000

IT cabinet

Storage
battery

Storage
battery

Cable
distribution
In-Row air
frame
conditioner IT cabinet

Contained cold aisle

End door

PDU 8000

Storage
battery

IT cabinet In-Row air IT cabinet


conditioner

Storage In-Row air


battery conditioner

IT cabinet

IT cabinet

IT cabinet

In-Row air
IT cabinet conditioner IT cabinet

Contained cold aisle

_ 6 -(20140911).indd 7-8

Cable
distribution
frame

IT cabinet

Cable
distribution
frame

Storage
battery

In-Row air
conditioner IT cabinet IT cabinet

M020-4D-4

Model

M030-6D-4

UPS capacity

20kVA

UPS capacity

30kVA

Number of IT racks

Number of IT racks

Power density

4kW/R

Power density

4kW/R

Redundancy

N+1

Redundancy

N+1

Backup time

30min

Backup time

40min

Dimensions

3.6m3m

Dimensions

3.6m3.6m

Model

M020-4S-4

Model

M030-6S-4

UPS capacity

20kVA

UPS capacity

30kVA

Number of IT racks

Number of IT racks

Power density

4kW/R

Power density

4kW/R

Redundancy

N+1

Redundancy

N+1

Backup time

30min

Backup time

40min

Dimensions

1.5m6m

Dimensions

1.5m7.2m

Model

M020-5D-3

Model

M030-8D-3

UPS capacity

20kVA

UPS capacity

30kVA

Number of IT racks

Number of IT racks

Power density

3kW/R

Power density

3kW/R

Redundancy

N+1

Redundancy

N+1

Backup time

30min

Backup time

40min

Dimensions

3.6m3.6m

Dimensions

3.6m4.2m

Model

M020-5S-3

Model

M030-8S-3

UPS capacity

20kVA

UPS capacity

30kVA

Number of IT racks

Number of IT racks

Power density

3kW//R

Power density

3kW/R

Redundancy

N+1

Redundancy

N+1

Backup time

30min

Backup time

40min

Dimensions

1.5m6.6m

Dimensions

1.5m8.4m

Contained cold aisle

End door

IT cabinet IT cabinet

PDU 8000

Storage
battery

Storage
battery

In-Row air
conditioner IT cabinet

In-Row air IT cabinet IT cabinet


conditioner

IT cabinet

IT cabinet

IT cabinet

End door

Cable
distribution
frame

In-Row air
conditioner

IT cabinet

IT cabinet

Cable
distribution
frame

Contained cold aisle

PDU 8000

End door

Storage
battery

Model

IT cabinet

Storage
battery

Storage
battery

In-Row air
conditioner IT cabinet

IT cabinet

IT cabinet

Contained cold aisle

End door

PDU 8000

Storage
battery

Storage
battery

IT cabinet

IT cabinet

In-Row air
IT cabinet conditioner IT cabinet

In-Row air IT cabinet


conditioner

IT cabinet

IT cabinet

IT cabinet

Contained cold aisle

End door

IT cabinet

Cable
distribution
frame

In-Row air
conditioner IT cabinet IT cabinet

IT cabinet

Cable
distribution
frame

2014/9/11 13:53:33

Specifications

Specifications

IDS2000 Typical Products 40kVA and 60kVA

IDS2000 Typical Products 80kVA and 120kVA

PDU 8000

Storage
battery

Storage
battery

In-Row air
conditioner

IT cabinet IT cabinet

Contained cold aisle

End door

IT cabinet

In-Row air IT cabinet IT cabinet


conditioner

End door

In-Row air
Cable
conditioner distribution
frame

Model

M040-5D-5

UPS capacity

40kVA

Number of IT racks

Power density

5kW/R

Redundancy

N+1

Backup time

30min

Dimensions

3.6m3.6m

Model

M080-11D-5

UPS capacity

80kVA

Number of IT racks

11

Power density

5kW/R

Redundancy

N+1

Backup time

15min

Dimensions

3.6m6m

M040-5S-5

Model

M080-7D-9

UPS capacity

40kVA

UPS capacity

80kVA

Number of IT racks

Number of IT racks

Power density

5kW/R

Power density

9kW/R

Redundancy

N+1

Redundancy

N+1

Backup time

30min

Backup time

15min

Dimensions

1.5m7.2m

Dimensions

3.6m4.8m

Model

M040-8D-4

Model

M120-10D-9

IT cabinet

In-Row air IT cabinet


conditioner

Storage
battery

Storage
battery

IT cabinet

PDU 8000

IT cabinet In-Row air IT cabinet


conditioner

IT cabinet

In-Row air
conditioner IT cabinet

IT cabinet

Cable
distribution
frame

Storage
battery

Storage
battery

IT cabinet In-Row air


conditioner

Storage
battery

End door

IT cabinet

In-Row air
conditioner IT cabinet

IT cabinet

IT cabinet IT cabinet

In-Row air
conditioner

IT cabinet

IT cabinet IT cabinet

In-Row air
conditioner

Cable
distribution
frame

Cable
distribution
frame

IT cabinet

Contained cold aisle

End door

IT cabinet In-Row air


conditioner

IT cabinet

End door

IT cabinet In-Row air IT cabinet


conditioner

In-Row air
PDU 8000 conditioner

Storage
battery

Storage
battery

IT cabinet

In-Row air
conditioner IT cabinet

Cable
distribution
frame

IT cabinet

IT cabinet

Cable
distribution
frame

40kVA

UPS capacity

120kVA

Number of IT racks

Number of IT racks

10

Power density

4kW/R

Power density

9kW/R

Redundancy

N+1

Redundancy

N+1

Backup time

30min

Backup time

30min

Dimensions

3.6m5.4m

Model

M120-17D-5

UPS capacity

120kVA

Number of IT racks

17

Power density

5kW/R

Redundancy

N+1

Backup time

30min

Dimensions

3.6m7.2m

Contained hot aisle

End door

IT cabinet In-Row air


conditioner

3.6m4.8m

IT cabinet

IT cabinet In-Row air IT cabinet


conditioner

End door

IT cabinet

In-Row air
Cable
conditioner distribution
frame

Note: The dimensions do not include external power area

End door

IT cabinet

IT cabinet

UPS capacity

Dimensions

Cable
distribution
frame

Contained cold aisle

End door

_ 6 -(20140911).indd 9-10

IT cabinet

Contained cold aisle

End door

Storage
battery

In-Row air
In-Row air
conditioner IT cabinet conditioner

Battery

PDU 8000

Storage
battery

Battery

Contained cold aisle

IT cabinet

IT cabinet

UPS

Cable
In-Row air distribution
IT cabinet conditioner
frame

In-Row air IT cabinet


conditioner

IT cabinet

PDU 8000

In-Row air
conditioner IT cabinet IT cabinet

End door

Model

M060-8D-5

UPS capacity

60kVA

Number of IT racks

Power density

5kW/R

Redundancy

N+1

Backup time

30min

Dimensions

3.6m5.4m

PDU 8000 IT cabinet

IT cabinet

In-Row air
conditioner IT cabinet

IT cabinet

IT cabinet

In-Row air
conditioner IT cabinet

IT cabinet

IT cabinet

Cable
distribution
frame

Battery

IT cabinet

IT cabinet

Contained cold aisle

IT cabinet

Battery

In-Row air
conditioner IT cabinet

IT cabinet IT cabinet

Contained hot aisle

End door

End door

UPS

Storage
battery

In-Row air
conditioner IT cabinet

PDU 8000

Storage
battery

Storage
battery

End door

PDU 8000 IT cabinet

PDU 8000

Cable
distribution
frame

Model

Storage
battery

PDU 8000 IT cabinet

IT cabinet

IT cabinet

IT cabinet

In-Row air IT cabinet


conditioner

IT cabinet

IT cabinet

In-Row air IT cabinet


conditioner

IT cabinet

IT cabinet

Cable
distribution
frame

Note: The dimensions do not include external power area

10

2014/9/11 13:53:37

Intelligent Management System


NetEco6000
Introduction

Technical Specification
IP

NetEco is a new generation data center management system launched


by HUAWEI. It manages the real-time data and status of data center
infrastructures, including power, environment, video, and door status and
generates alarms if any fault occurs.

Mornitoring
System

NetEco
System

Internet

Monitoring Systems
Bottom-layer equipments can be easily connected to NetEco over Modbus, Simple Network Management Protocol (SNMP), and
intelligent equipment communication protocol. Customers can customize NetEco for the support of non-standard protocols. Bottomlayer devices monitored by the NetEco are classified into the power system, environment system, video system, and access system.

NetEco displays data center layouts and data reports for customers to easily
query equipment status, and provides a standard platform to apply to all
data center solutions due to its flexible configuration, smooth capacity
expansion, and hierarchical management.

Application Scenarios

Power System

Environment System

Video System

Access System

Precision air conditioner,


UPS, PDU, UPS input cabinet,
UPS output cabinet, Precise
PDF, AC PDF

Temperature and humidity


sensor, smoke sensor,
water sensor

Camera, NVR (Optional)

Door access controller

Apply to IDS1000 and IDS2000 data center solutions

Value & Features


High availability, warning and troubleshooting
Foresight warning of faults and risks improves IDC availability
Quickly faults location, virtual inspection
Smart interaction, energy saving
Dynamic PUE management
Optimizing important power and cooling services
Rapid deployment, one -button launching
Pre-configured software and parameters, one-button launching
Parameters of AC and UPS loading, testing time saving
Easy visualization maintenance in 3D view
The 3D design tool realizes 3D visual maintenance
Dynamic 3D display of site temperature, eliminating hot spots

Functions
NetEco provides comprehensive functions for managing data center infrastructures.

PDF

Power Analysis

_ 6 -(20140911).indd 11-12

Resource
Management

Management
Level

Monitoring
Level

11

Capacity
Management

Analysis
Level

View
Management

Work-Order
Management

Performance
Management

System (Safety)
Management

Report
Management

Fault
Management

12

2014/9/11 13:53:38

Global Applications
The offerings in the Huawei data center facilities solutions have been successfully
applied in China Mobile Southern Base, China Telecom, Phoenix TV, India NxtGen,
Maldives smart- government, Venezuela CanTV, etc.

More than 10-year data center service experiences, more than 400 data centers (
including 120 'Cloud' data centers ) all around the world.

Netherlands/BOC
branch data centers

Russia/MasterTel

China Mobile
/North China Logistics IDC

England/channel
China Unicom (Beijing) IDC

Iraq
/Video Surveillance Data Center

Tencent (Tianjin) IDC


Saudi/MOI
China Telecom (Shanghai) IDC

Togo/Lome
university

Mexico/IPCYT

Guyana/E-Gov
Huawei desktop cloud
container DC

Ghana/E-Gov

Venezuela/CANTV

Brazil/Mackenzie university

China Mobile
/Southern base IDC

India
/NxtGen data center

Brazil/Petrobras

Ethiopia
/METEC data center

Maldives smart
/government IDC

Chile/Codelco
Samoa/National broadband

13