ARES

AUTOMATIC RESISTIVITY SYSTEM

2000 Vp-p - 5A - 850 W (Adjustable 300 / 600 / 850 W)


Applications:
groundwater explorations, geotechnical investigations,
measurements on dams and dikes, environmental studies,
geological surveys, mineral prospecting, archaeology and
many others.

Resistivity & IP
Up to 10 adjustable IP windows
2D/3D Resistivity Tomography
Multi - Electrode Arrays, VES, RP, SP
Borehole Survey
Easy-Control System

ARES represents a new well equipped resistivity and IP imaging system of the third
generation designed by GF instrument.
its variability, easy operating (without PC), feeding from a standard 12 V battery
and compatibility with widespread interpretation software makes ARES a cost effective and useful
tool for working groups and research teams

, s.r.o.

M PT. MITRA INTI MARGA

SUPPLI ER FOR LABORA TORIES & RESEARCH INSTI TUTES

ARES - Technical Specifications


Transmitter
Power
Voltage
Current
Protection
Precision
Efficiency
Powerfull passive colling, working internal temperature

850 W (adjustable 300 / 600 / 850 W)


15 - 1000 V (2000 Vp-p)
5A
full electronic protection
0,1%
up to 91%
<75 C

Receiver
Input impedance
Input voltage range
Mains frequency filtering
Precision

20 M
5V
50 or 60 Hz
0.1%

Supported methods

Supported Arrays

2D/3D Multi-Electrode Resistivity and IP Tomography


VES - Resistivity Electrical Sounding
RP - Resistivity Profiling
SP - Self Potential
Borehole Survey
User Defined Survey

Wenner Alpha / Beta / Gamma


Wenner-Schlumberger
Dipole-Dipole
Pole-Dipole
Reverse Pole-Dipole
Pole-Pole
MGM
Equatorial dipole-dipole
User defined configurations

Measurement - feature

Self-adapting control system, automatic ranging and calibration


Automatic checking of measured values
Easy interruption of the measurement (for the first view of measured structures)
Capability of profile prolongation by means of multi-electrode cable rolling
available for all 1D / 2D / 3D methods
Up to 10 adjustable IP windows, each max. 30 s, step 20 / 16.66 ms
0.3 s - 30 s, step 0.1 s
constant and linear, time-invariant
manual or automatic (with self-adaptive setting)
measured voltage and maximum acceptable measurement error
position of the measured point, output current, input voltage, SP, apparent resistivity,
standard deviation, chargeability with standard deviation for all 10 IP windows
RES2DIV / RES3DIV, (and others)
200 (connected in one array)

IP - Induced Polarization (Chargeability)


Pulse
SP compensation
Stacking
Adjustable optimum
Storage values
Output data format
Maximum number of electrodes

Control unit
Memory
Interface
Power supply
Connectors
Dimensions
Weight
Ambient conditions

Easy-Control system, no need of PC for the measurement


Alphanumeric keyboard, large LCD display
Safety switch
16 Mbit, up to 100 files 70000 readings
RS232 or USB
12 V car battery or attachable battery pask
for PC, battery and a universal one all measuring accessories (Multi-Electrode Cable, VESAdapter)
13 x 17 x 39 cm
5.8 kg
-10 C to +50 C, weatherproof

Optional accessories:

Standard Accessories:

(subject to continuous development)


12 V / 300 W attachable battery pak with fast 3-stage battery charger
Multi-Eletrode cable section - active (interligent) and passive multi-conductor (classic)
Attachable 48-channel 2A / 575 V adapter for multi-conductor cable
VES-adapter (for 5 pairs of potential electrodes)
Cable reels
Standard electrodes, non-polarisable electrodes
Interpretation and mapping software

Transport case
T-piece (for connection of multi-electrode cable sections
And cables for current and potential electrodes)

Cable for external 12 V battery


RS232 and USB cables
AC Adapter (for all countries)
Measuring software ARES

INDONESIA Authorized Agent


Please Contact :

PT. MITRA INTIMARGA


BEKASI SQUARE - Kanto No. 70
Pekayon Jaya - Bekasi Selatan 17148
Phone No. (021) 8243 4829
Fax No. (021) 8243 4831
E-mail : sales@ptmitra.com