Vous êtes sur la page 1sur 28

Renewal Parts Data

33-790-1H
Page

October, 1996
Supersedes Renewal Parts Data 33-790-1G
pages 1-20 dated December, 1988
Mailed to: C, D, E/33-700

Westinghouse
DS and DSL
Low Voltage
Power Circuit
Breakers and
Cell Parts

Contents
Pages
DS Breaker (Front and Rear View)
2
Procedure for Identifying Breaker Type
2
Ordering
Instructions
3
Sample Order Form
3
Pole Units
4-7
Arc Chutes
8
Barriers
9
Main
Disconnecting
Contacts
10
Levering
Mechanism
11
Mechanism and Related Parts
12-13
Control
Components
14-16
Automatic
Tripping
System
17-19
Current
Sensors
20
DSL Current Limiting Breakers
21
Switchgear Cell Parts
22-25
Accessories and Other Parts
26-27
Switchgear
Cell
Provisions
and
Upgrades
28
Recommended
Spares
28

October, 1996

Renewal Parts Data

33-790-1H
Page

DS LOW VOLTAGE POWER CIRCUIT BREAKERS


Escutcheon Plate
Digitrip Trip Unit
Inside Wiring Guide
Nameplate
Outside Wiring Guide
Emergency
Charging Handle

Shutter
Drawout Unit
Position Indicator

Open-Close Indicator

Padlock Plate
Close Bar

Trip Plate
Spring Charge Indicator

Front Cover

Figure 2.1 DS-416 Breaker Front View


Automatic Trip
Relay (ATR)

Digitrip Trip Unit


Rating Plug

Auxiliary Switch
Wire Guide
Auxiliary Switch

PT Module
(700 and 800
Only)

Secondary Disconnect
Contact Mounting Frame
Secondary
Disconnect
Contact Cover

Auxiliary
Switch

Moving
Secondary
Disconnect
Contacts

Auxiliary
Current
Sensors

Emergency
Charging
Handle

Main
Disconnect
Contacts

Levering
Mechanism
Assembly

Shunt
Trip
Direct
Trip
Actuator
Overcurrent
Trip
Switch

Arc Chutes

Levering
Device
Arm
Spring Charge Motor
(Power Operated
Breakers Only)

Opening Spring

Figure 2.2 DS-416 Breaker with Front Cover Removed

Sensors
Roller
(4 per Breaker)

Figure 2.3 DS-416 Breaker Side View without Barriers

October, 1996

Renewal Parts Data

33-790-1H
Page

PROCEDURE FOR
ORDERING INSTRUCTIONS
IDENTIFYING BREAKER TYPE
A breaker is identified by the data found on the nameplate.
Shop Order or S.O. numbers were used to identify
breakers until September 1990. These S.O. numbers
were usually seven characters constructed with two
numbers followed by a letter and then an additional four
numbers. Examples are:
24Y7859
80Y3800
27Y3838
81Y8500
28Y5868
82Y1260
After September 1990, DS breakers were identified using
three unique numbers. One is the G.O. (general order
number), the second is a 10 character F.N. (feature
number) and the third is a 20 character OPTION number.
An example is:
G.O.
CG12345
F.N.
6616C31G02
Option
Number:
10200 80700 00010 00000

1 . Check the nameplate to identify the type of


breaker you have. (If adding accessories or
options to existing breakers, you must also
provide the information in the procedure listed to
the left.)
2 . Identify the part(s) from the photos shown.
3 . Determine the style number for the required
parts.
4 . Specify the quantity required.
5 . Use the form below and order the parts from your
local Cutler-Hammer distributor.
6 . State the method of shipment.

Refer to Figure 2.1 for this type of nameplate.


-----------------------------------------------------------------------------------------------------------------------------------------------------------DS BREAKER RENEWAL PARTS ORDER FORM
Company

Name

and

Address

Contact
Person
Purchase
Order
Method of Shipment
Phone
Number

Date

REQUIRED INFORMATION
Shop
Order
General

Order

Option

Number

Breaker

Type

Breaker

Control

Number

Feature

Frame
Voltage

Motor

Number

Amp

Rating

Voltage

Hertz
Trip

Voltage

PARTS LIST
ITEM

QTY

October, 1996

DESCRIPTION

STYLE NUMBER

UNIT PRICE

Renewal Parts Data

33-790-1H
Page

POLE UNITS
Type DS-206, DSL-206

Figure 4.1 DS-206 Pole Unit Assembly

Front View

Figure 4.3 DS-206 Lower Stud Assembly

Three

Pole

Unit

Assembly

A three pole unit assembly includes:


Molded
Base
Lower Stud Assembly
Upper Stud Assembly

Rear View

Figure 4.4 DS-206 Upper Stud Assembly

Figure
Number

Description

Figure 4.2 DS-206 Pole Unit Assembly

No.
Req'd
Per
Breaker

DS-206
Style
Number

DSL-206
Style
Number

4.1, 4.2

140D152G05

140D152G07

4.3
4.4

3
3

591C652G01
591C653G01

591C652G03
591C653G03

Only available in a three pole unit assembly.

October, 1996

Renewal Parts Data

33-790-1H
Page

POLE UNITS
Type DS-206E, DS-206H, DS-206S,DS-416,
DSL-416,DS-416H, DS-416S, DS-420, DSL-420

Figure 5.1 DS-416 Pole Unit Assembly

Front View

Figure 5.3 DS-416 Lower Stud Assembly

Description
Single

Pole

Unit

Assembly

A single pole unit Includes:


Molded
Base
Lower Stud Assembly
Upper Stud Assembly

Figure 5.2 DS-416 Pole Unit Assembly

Figure 5.4 DS-416 Upper Stud Assembly

DS-206H
DS-206S
DS-416
Style
Number

DSL-416
Style
Number

DS-206E
DS-416H
DS-416S
DS-420
Style
Number

DSL-420
Style
Number

Figure
Number

No.
Req'd
Per
Breaker

5.1, 5.2

151D064G01

151D065G01

151D065G02

151D065G08

5.3
5.4

3
3

126D298G06
591C750G02

139D633G04
139D635G01

139D633G05
139D635G02

139D633G06
139D635G01

Only available in a single pole unit assembly.


This is a direct replacement pole unit. It is different in appearance than the original.
October, 1996

Rear View

Renewal Parts Data

33-790-1H
Page

POLE UNITS
Type DS-632

Figure 6.1 DS-632 Pole Unit Assembly

Front View

Figure 6.3 DS-632 Lower Stud Assembly

Description
Single Pole

Unit Assembly

A single pole unit assembly


Molded
Base
Lower
Upper

Stud
Stud

Figure 6.2 DS-632 Pole Unit Assembly

Rear View

Figure 6.4 DS-632 Upper Stud Assembly

Figure
Number

No.
Req'd
Per
Breaker

6.1, 6.2

6.3
6.4

3
3

DS-632
Style
Number
567F962G01

includes:

Assembly
Assembly

140D091G05
126D299G02

Only available in a single pole unit assembly.

October, 1996

Renewal Parts Data

33-790-1H
Page

POLE UNITS
Type DS-840

Figure 7.1 DS-416 Pole Unit Assembly

Front View

Figure 7.3 DS-840 Lower Stud Assembly

Description
Single Pole

A single pole unit assembly


Molded
Base
Lower
Upper

Stud
Stud

7.1, 7.2

No.
Req'd
Per
Breaker
3

DS-840
Style
Number
567F991G03

includes:

Assembly
Assembly

Only available in a single pole unit assembly.

October, 1996

Figure 7.4 DS-840 Upper Stud Assembly

Figure
Unit Assembly

Figure 7.2 DS-840 Pole Unit Assembly

7.3
7.4

3
3

140D778G01
140D779G01

Rear View

Renewal Parts Data

33-790-1H
Page

ARC CHUTES

Arc Chutes

Figure 8.1 DS-840 without Barriers

Figure 8.2

Figure 8.3

Figure 8.4

Breaker Type
DS-206,

DSL-206

Figure
Number

No.
Req'd
Per
Breaker

Arc Chute Kit


(Includes 3)
Style
Number

8.2

1A33568G01

DS-206E, DS-206H, DS-206S


DS-416, DS-416H, DS-416S, DSL-416
DS-420, DSL-420

8.3

1A33568G02

DS-632

8.4

1A33568G03

DS-840

8.5

1A33568G04

Figure 8.5

October, 1996

Renewal Parts Data

33-790-1H
Page

BARRIERS

Barriers

Figure 9.1 DS-840 with Barriers

Figure 9.2

Figure 9.4

Figure 9.3

Figure
Number

Breaker Type
DS-206,

DSL-206

October, 1996

Barrier Kit
(Includes 4)
Style
Number

9.2

1A33569G01

9.3

1A33569G02

DSL-420

9.3

1A33569G03

DS-632

9.4

1A33569G04

DS-840

9.5

1A33569G05

DS-206E, DS-206H, DS-206S


DS-416, DS-416H, DS-416S, DSL-416,

Figure 9.5

No.
Req'd
Per
Breaker

DS-420

Renewal Parts Data

33-790-1H
Page

10

MAIN DISCONNECT CONTACT ASSEMBLY

Figure 10.1

Figure 10.2

Figure 10.4

Figure 10.5

Breaker Type
DS-206,

DSL-206

Figure 10.3

Figure
Number

No.
Req'd
Per
Breaker

Main
Disconnect
Contact
Assembly Kit

800

10.1

1A33570G01

Maximum
Amp.
Rating

DS-206H, DS-206S, DS-416,

DSL-416

1600

10.2

1A33570G02

DS-206E,

DS-416H,

DS-420

2000

10.3

1A33570G03

DSL-420,

DS-632

3200

10.4

1A33570G04

4000

10.5

12

1A33570G05

DS-840

DS-416S,

A kit includes the total number of main disconnect contact assemblies required for one breaker.

October, 1996

Renewal Parts Data

33-790-1H
Page

11

MECHANISM

Figure 11.1
Levering Mechanism Assembly

Description
Levering

Mechanism

Crank Kit includes:


Crank Arm with Roller,
Special Bolt and Elastic
Stop Nut

October, 1996

Assembly

Figure 11.2
Crank Kit

All Types
DS/DSL
except DSL-420,
DS-632 and DS-840
Style
Number

DSL-420
DS-632
Style
Number

DS-840
Style
Number

Figure
Number

No.
Req'd
Per
Breaker

11.1

449D224G04

449D224G04

449D224G05

11.2

3838A95G01

3838A95G02

3838A95G03

Renewal Parts Data

33-790-1H
Page

12

MECHANISM and RELATED PARTS

Figure 12.1
Electrically Operated with Closing Spring

Figure 12.2
Manual Mechanism with Closing Spring

Figure 12.3
Closing Spring Assembly

Figure 12.4
Emergency Charge Handle Kit

Figure 12.5
Manual Charge Handle Kit with
Charging Cams

Figure 12.6
Oscillator Assembly Kit

Figure 12.7
Opening Spring

Figure 12.8
Trip Shaft Kit

Figure 12.9
Hold Pawl and Rachet Kit

October, 1996

Renewal Parts Data

33-790-1H
Page

13

MECHANISM and RELATED PARTS

Figure
Number
12.1

Description
Mechanism
Assembly
w/o Closing Spring
Includes: Main Drive Link
Assembly
(w/roller),
Oscillator
Assembly,
Oscillator Reset Spring,
Emergency
Charge
Device,
Trip Latch, Trip Lever (for
Motor Cutoff Switch), Trip
Latch Reset Spring

No Req'd
Per
Breaker
1

All DS/DSL except


DS-632 and DS-840
Electrically
Manually
Operated
Operated
Style
Style
Number
Number
567F759G02
N/A

Electrically
Operated
Style
Number
567F759G04

Manually
Operated
Style
Number
N/A

N/A

N/A

567F759G07

791A671G03

791A671G03

Mechanism
Assembly
w/o Closing Spring
Includes: Main Drive Link
Assembly
(w/roller),
Trip Latch, Trip Lever (for
Motor Cutoff Switch), Trip
Latch Reset Spring

12.2

Closing
Spring
Assembly
Includes: Closing Spring and
Spring
Ends
DS-206, DS-206S, DSL-206
DS-206H, DS-416, DS-416S,
DSL-416, and DSL-420
DS-206E, DS-416H, DS-420

12.3

12.3
12.3

2
2

349A521G01
791A671G02

349A521G01
791A671G02

12.3

791A671G01

791A671G01

Emergency Charge Handle Kit


Includes:
Emergency
Charge
Device and Emergency
Charge
Handle

12.4

3838A96G02

N/A

3838A96G02

N/A

Manual Charge Handle Kit


Includes: Manual Charge
Assembly and Manual
Charge Handle and Charging

12.5

N/A

3838A96G01

N/A

3838A96G01

Oscillator Assembly Kit


Includes:
Oscillator
Assembly,
and Oscillator Reset Spring

12.6

1A33566G01

N/A

1A33566G01

N/A

Opening

12.7

698B907H01

698B907H01

698B907H01

698B907H01

Trip Shaft Kit


Includes: Trip Shaft Lever,
Trip Shaft, and Trip Shaft
Return
Spring

12.8

1A33567G01

1A33567G01

1A33567G01

1A33567G01

Hold Pawl and Rachet Wheel Kit

12.9

1A33579G01

N/A

1A33579G01

N/A

Spring

Cams

Two Opening springs are required for DS-632 and DS-840

October, 1996

567F759G01

DS-632 and DS-840

Renewal Parts Data

33-790-1H
Page

14

CONTROL COMPONENTS

Figure 14.1
Spring Charging Motor Kit

Figure 14.2
Anti-Pump Relay

Figure 14.3
Undervoltage Trip Assembly

(Coil
Figure 14.4
Latch Check Switch

Figure 14.5
Shunt Trip Assembly

Figure 14.7
Spring Release Assembly

Figure 14.8
Motor Cut-Off Switch

not

shown)

Figure 14.6
Overcurrent Trip Switch Manual Reset

October, 1996

Renewal Parts Data

33-790-1H
Page

15

CONTROL COMPONENTS

Description
Spring
Charging
Motor Kit
Includes:
Motor
Crank, Roller,
Connectors,
Mtg. Bracket
and
Hardware
Anti-Pump
Relay

Undervoltage
Trip
Assembly
w/wires
(Instantaneous)

Undervoltage
Trip
Assembly
w/wires
(Time
Delay)

Latch Check
Switch

Fig.
No.
14.1

14.2

14.3

14.3

14.4

Voltage
48 DC
125 DC
250 DC
120 60HZ
240 60HZ

DS/DSL
except
DS-840
Style
Number
449D431G03
449D431G01
449D431G02
449D431G01
449D431G02

DS-840
Style
Number
449D431G03
449D431G01
449D431G02
449D431G01
449D431G02

48 DC
125 DC
250 DC
120 60HZ
240 60HZ

8293A05G03
8293A05G04
8293A05G05
8293A05G01
8293A05G02

8293A05G03
8293A05G04
8293A05G05
8293A05G01
8293A05G02

120 60HZ
208 60HZ
240 60HZ
480 60HZ
48 DC
125 DC
250 DC
24 DC
115 50HZ
208 50HZ
230 50HZ
400 50HZ
415 50HZ
480 50HZ
120 60HZ
208 60HZ
240 60HZ
480 60HZ
48 DC
125DC
250DC
24 DC
115 50HZ
208 50HZ
230 50HZ
400 50HZ
415 50HZ
480 50HZ

3752A05G01
3752A05G02
3752A05G03
3752A05G04
3752A05G05
3752A05G06
3752A05G07
3752A45G01
3752A45G02
3752A45G03
3752A45G04
3752A45G05
3752A45G05
3752A45G06
3752A06G01
3752A06G02
3752A06G03
3752A06G04
3752A06G05
3752A06G06
3752A06G07
3752A46G01
3752A46G02
3752A46G03
3752A46G04
3752A46G05
3752A46G05
3752A46G06

3752A25G01
3752A25G02
3752A25G03
3752A25G04
3752A25G05
3752A25G06
3752A25G07
3752A45G01
3752A45G02
3752A45G03
3752A45G04
3752A45G05
3752A45G05
3752A45G06
3752A26G01
3752A26G02
3752A26G03
3752A26G04
3752A26G05
3752A26G06
3752A26G07
3752A46G01
3752A46G02
3752A46G03
3752A46G04
3752A46G05
3752A46G05
3752A46G06

All

140D161G01

140D161G01

Replacement shunt trip, spring


(not shown). If adding shunt trip,
kit (page 27) are required. Confirm
should be wired per the standard
October, 1996

Description
Shunt Trip
Assembly
w/wires

Fig.
No.
14.5

Voltage
24 DC
32 DC
48 DC
125 DC
250 DC
120 60HZ
240 60HZ
For use
with
Capacitor
Trip(125VDC)

DS/DSL
except
DS-840
Style
Number
3752A02G01
3752A02G02
3752A02G03
3752A02G04
3752A02G05
3752A02G06
3752A02G07
3752A02G08

DS-840
Style
Number
3752A22G01
3752A22G02
3752A22G03
3752A22G04
3752A22G05
3752A22G06
3752A22G07
3752A22G08

Overcurrent
14.6
Trip Switch
Manual
Reset
(2 Cont. w/wires)

All

3752A04G01

3752A24G01

Overcurrent
14.6
Trip Switch
Manual
Reset
(3 Cont. w/wires)

All

3752A04G02

3752A24G02

Overcurrent
14.6
Trip Switch
Manual
Reset
(4 Cont. w/wires)

All

3752A04G03

3752A24G03

Overcurrent
14.6
Trip Switch
Electrical Reset
includes
coil
(2 Cont. w/wires)

48 DC
115 AC
125 DC
230 AC
250 DC

3752A04G04
3752A04G05
3752A04G06
3752A04G07
3752A04G08

3752A24G04
3752A24G05
3752A24G06
3752A24G07
3752A24G08

Overcurrent
14.6
Trip Switch
Electrical Reset
includes
coil
(3 Cont. w/wires)

48 DC
115 AC
125 DC
230 AC
250 DC

3752A04G09
3752A04G10
3752A04G11
3752A04G12
3752A04G13

3752A24G09
3752A24G10
3752A24G11
3752A24G12
3752A24G13

Spring
Release
Assembly

w/wires

48 DC
125 DC
250 DC
120 60HZ
240 60HZ

3752A03G01
3752A03G02
3752A03G03
3752A03G04
3752A03G05

3752A23G01
3752A23G02
3752A23G03
3752A23G04
3752A23G05

14.7

Motor
Cut-off
14.8 A l l
567F430G06 567F430G06
Switch
Includes:
Mounting
Brkt.
and
Insulation
release and undervoltage trip are complete assemblies and include mounting hardware and wire leads
spring release or undervoltage trip to manual breakers; an auxiliary switch (page 16), and wiring guide
that secondary contacts exist in the rear of the breaker. All changes or additions on the breaker
drawing 508B508 and indicate the change on the breaker nameplate.

Renewal Parts Data

33-790-1H
Page

16

CONTROL COMPONENTS

Mounting

Auxiliary

Screw

Switch

Top Cover

End Cover

Figure 16.1
New Auxiliary Switch Assembly Kit (round) - one high

New Auxiliary Switch Assembly Kit (round)


(Includes mounting bracket, switch, covers,

Style Number
and

screw)

1 High Assembly Kit


2 High Assembly Kit

1A33571G01
1A33571G02

Additional Auxiliary Switch Assembly


2 n d Auxiliary
3 r d Auxiliary

w/cover (rectangular)

Switch
Switch

697B536G08
697B536G09

Replacement Auxiliary Switches Assembly (rectangular)


(Includes: switch, drive
link and hardware)
1 s t Auxiliary
2 n d Auxiliary
3 r d Auxiliary

Switch (ABAB
Switch
Switch

only)

Replacement Auxiliary Switch Only


A B A B Auxiliary
A A A A Auxiliary
B B B B Auxiliary
A A A B Auxiliary
A B B B Auxiliary
A = N.O.
B

Switch
Switch
Switch
Switch
Switch
= N.C.

697B536G04
697B536G05
697B536G06
(rectangular)
449D622G33
449D622G34
449D622G35
449D622G36
449D622G37

When adding an auxiliary switch, be


sure that the wiring guides are installed.
There are three wiring guides and they are
located as follows: one inside and one
outside on the left side of the breaker, and
one between the right side of the trip unit
and the auxiliary switch.
Refer to figures
2.1 and 2.2. for location and to page 27 for
style numbers. Additional secondary
contacts and covers may be required.
Refer to figure 2.3 and page 27 for the style
number.
For adding to breakers with existing
rectangular
auxiliary
switches.
Used for replacement only of existing
rectangular
auxiliary
switches.

October, 1996

Renewal Parts Data

33-790-1H
Page

17

AUTOMATIC TRIPPING SYSTEMS

Figure 17.1
Amptector I-A Solid State Trip
Amptector I-A
can be supplied in various combinations of four
independent
continuously
adjustable
overcurrent
tripping
functions:
Long delay (L)
Short delay (S)
Instantaneous
(I)
Ground
(G)
The following combinations are available:
LI
LSIG
LIG
LSG
LSI

Model
LI
LIG
LS
LSG
LSIG
LSI

All Types
DS/DSL
except DS-632
and DS-840
60 HZ.
Figure
Style
Number Number
17.1
1233C97G01
17.1
1233C97G02
17.1
1233C97G03
17.1
1233C97G04
17.1
1233C97G05
17.1
1233C97G06

October, 1996

DS-632
60 HZ.
Style
Number
1233C97G01
1233C97G62
1233C97G03
1233C97G64
1233C97G65
1233C97G06

DS-840
60 HZ.
Style
Number
1233C97G01
1233C97G82
1233C97G03
1233C97G84
1233C97G85
1233C97G06

Figure 17.2
Direct Trip Actuator (DTA)
For use with Amptector I-A Trip System
For use with Digitrip Box
For use with Digitrip Mounting

6482C55G21
6482C55G28
6482C55G11

There are various vintages of Amptector solid state tripping


devices (Amptector, Amptector I, and II, and Amptector I-A and
I I -A).
Amptector I -A is the only vintage of Amptector trip system
currently available.
(AVAILABLE THROUGH DECEMBER 1996
ONLY). After December 1996 and for all other vintages of
Ampector trip systems; a Digitrip retrofit kit is available. (Additional secondary contacts may be required). Contact your local
Cutler-Hammer distributor for detail information.
For information on application and operation of the Amptector
automatic tripping system, refer to section 8 of Instruction Book
33-790-1G.

Renewal Parts Data

33-790-1H
Page

18

AUTOMATIC TRIPPING SYSTEMS

Potential
Transformers
(PT
Module)

Digitrip

Rating
Plug

Power
Figure 18.1
Digitrip Box
(800 Box shown)

Relay

Module(ATR)

Figure 18.2
Digitrip Mounting
w/ATR and PT Module

The Digitrip Box (figure 18.1) was used prior to June 1994 and on
breakers identified by style series 6616C _ _ G02. The Digitrip
Mounting (figure 18.2) was used after June 1994 and is identified
by breakers with style series 6616C _ _ G03. This series of
breakers used the Digitrip 500, 600, 700, and 800 trip units. After
August 1994, the Digitrip 510, 610, 810, and 910 trip units were
used and these breakers are identified by style series
6616C _ _ G04.
Digitrip Box
Type of
Trip Unit
500 w/Gnd
500 w/o Gnd
600 w/Gnd and ATR
600 w/o Gnd and ATR
700 w/ Gnd, ATR, and PT
700 w/o Gnd, w/ATR and
800 w/ Gnd, ATR, and PT
800 w/o Gnd, w/ ATR and
Digitrip Mounting
Type of
Trip Unit
500/510 w/Gnd
500/510 w/o Gnd
600/610 w/Gnd
600/610 w/o Gnd
700/800/810/910 w/ Gnd,
ATR, and PT module
700/800/810/910 w/o Gnd
and w/ATR and PT module

Figure
Number
18.1
18.1
18.1
18.1
module
18.1
PT module
18.1
module
18.1
PT module
18.1

Style
Number
694C501G01
694C501G02
694C501G03
694C501G04
694C501G05
694C501G06
694C501G05
694C501G06

Figure
Number
18.2
18.2
18.2
18.2

Style
Number
694C735G01
694C735G02
694C735G03
694C735G04

18.2

694C735G05

18.2

694C735G06

Figure
Number
18.3
18.3

Style
Number
694C740G01
694C740G02

Auxiliary CT Mounting
Type
w/Gnd
w/o Gnd

Figure 18.3
Auxiliary CT Mounting
(for use with Digitrip Mounting)

Figure 18.4
Digitrip w/Rating Plug

Digitrip (Figure 18.4)


Trip
Trip
Unit
Functions
500
LI
500
LSI
500
LS
500
LIG
500
LSG
500
LSIG
600
LI
600
LSI
600
LS
600
LIG
600
LSG
600
LSIG
700
LI
700
LSI
700
LS
700
LIG
700
LSG
700
LSIG
800
LI
800
LSI
800
LS
800
LIG
800
LSG
800
LSIG
510
LI
510
LSI
510
LS
510
LIG
510
LSG
510
LSIG
610
LI
610
LSI
610
LS
610
LIG
610
LSG
610
LSIG
810
LI
810
LSI
810
LS
810
LIG
810
LSG
810
LSIG
910
LI
910
LSI
910
LS
910
LIG
910
LSG
910
LSIG

Style
Number
No Longer
Available.
Replace
With
Digitrip
510
No Longer
Available.
Replace
With
Digitrip
610
No Longer
Available.
Replace
With
Digitrip
810
No Longer
Available.
Replace
With
Digitrip
810 or 910
7829C05G01
7829C05G02
7829C05G03
7829C05G04
7829C05G05
7829C05G06
7829C10G01
7829C10G02
7829C10G03
7829C10G04
7829C10G05
7829C10G06
7829C08G01
7829C08G02
7829C08G03
7829C08G04
7829C08G05
7829C08G06
7829C09G01
7829C09G02
7829C09G03
7829C09G04
7829C09G05
7829C09G06

October, 1996

Renewal Parts Data

33-790-1H
Page

19

AUTOMATIC TRIPPING SYSTEMS


Digitrip Rating Plugs
Digitrip Rating Plugs for 500, 600, 700, 800
Rated
Current
Current
Sensor
In
Rating
Hertz
100
200
200
250
300
200
250
300
400
300
400
600
400
600
800
600
800
1000
1200
800
1000
1200
1600
1000
1200
1600
2000
1600
2000
2400
1600
2000
2400
3000
3200
2000
2400
3200
4000
3200
4000
5000
100
200
200
250
300
200
250
300
400
300
400
600
400
600
800
600
800
1000
1200
800
1000
1200
1600
1000
1200

200
200
300
300
300
400
400
400
400
600
600
600
800
800
800
1200
1200
1200
1200
1600
1600
1600
1600
2000
2000
2000
2000
2400
2400
2400
3200
3200
3200
3200
3200
4000
4000
4000
4000
5000
5000
5000
200
200
300
300
300
400
400
400
400
600
600
600
800
800
800
1200
1200
1200
1200
1600
1600
1600
1600
2000
2000

60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50

For use with forced air cooled DS-840 only.


October, 1996

Style
Number
2613D10G01
2613D10G02
2613D10G03
2613D10G04
2613D10G05
2613D10G06
2613D10G07
2613D10G08
2613D10G09
2613D10G10
2613D10G11
2613D10G12
2613D10G13
2613D10G14
2613D10G15
2613D10G16
2613D10G17
2613D10G18
2613D10G19
2613D10G20
2613D10G21
2613D10G22
2613D10G23
2613D10G24
2613D10G25
2613D10G26
2613D10G27
2613D10G28
2613D10G29
2613D10G30
2613D10G31
2613D10G32
2613D10G33
2613D10G42
2613D10G34
2613D10G35
2613D10G36
2613D10G37
2613D10G38
2613D10G39
2613D10G40
2613D10G41
2613D12G01
2613D12G02
2613D12G03
2613D12G04
2613D12G05
2613D12G06
2613D12G07
2613D12G08
2613D12G09
2613D12G10
2613D12G11
2613D12G12
2613D12G13
2613D12G14
2613D12G15
2613D12G16
2613D12G17
2613D12G18
2613D12G19
2613D12G20
2613D12G21
2613D12G22
2613D12G23
2613D12G24
2613D12G25

Digitrip Rating Plugs for 500, 600, 700, 800


Rated
Current
Current
Sensor
In
Rating
Hertz
1600
2000
1600
2000
2400
1600
2000
2400
3000
3200
2000
2400
3200
4000
3200
4000
5000

2000
2000
2400
2400
2400
3200
3200
3200
3200
3200
4000
4000
4000
4000
5000
5000
5000

50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50

Digitrip Rating Plugs for 510, 610, 810, 910


Rated
Current
Current
Sensor
In
Rating
Hertz
100
200
200
250
300
200
250
300
400
300
400
600
400
600
800
600
800
1000
1200
800
1000
1200
1600
1000
1200
1600
2000
1600
2000
2400
1600
2000
2400
3000
3200
2000
2400
3200
4000
3200
4000
5000

200
200
300
300
300
400
400
400
400
600
600
600
800
800
800
1200
1200
1200
1200
1600
1600
1600
1600
2000
2000
2000
2000
2400
2400
2400
3200
3200
3200
3200
3200
4000
4000
4000
4000
5000
5000
5000

50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60

Style
Number
2613D12G26
2613D12G27
2613D12G28
2613D12G29
2613D12G30
2613D12G31
2613D12G32
2613D12G33
2613D12G42
2613D12G34
2613D12G35
2613D12G36
2613D12G37
2613D12G38
2613D12G39
2613D12G40
2613D12G41

Style
Number
3D86734G01
3D86734G02
3D86734G03
3D86734G04
3D86734G05
3D86734G06
3D86734G07
3D86734G08
3D86734G09
3D86734G10
3D86734G11
3D86734G12
3D86734G13
3D86734G14
3D86734G15
3D86734G16
3D86734G17
3D86734G18
3D86734G19
3D86734G20
3D86734G21
3D86734G22
3D86734G23
3D86734G24
3D86734G25
3D86734G26
3D86734G27
3D86734G28
3D86734G29
3D86734G30
3D86734G31
3D86734G32
3D86734G33
3D86734G42
3D86734G34
3D86734G35
3D86734G36
3D86734G37
3D86734G38
3D86734G39
3D86734G40
3D86734G41

Renewal Parts Data

33-790-1H
Page

20

AUTOMATIC TRIPPING SYSTEMS


Current Sensors

Spacer - DS 206 only (Required 2/Sensor)


Figure 20.1
DS-206 Sensor w/Spacer

Sensor Ampere Rating


100
150
200
300
400
600
800
1200
1600
2000
2400
2400
3200
3200
3200
4000
5000

Figure 20.3
DS-840 Sensor

Figure 20.2
DS-632 Sensor

All DS-206,
All DS-206,
All DS-206,
All DS-206,
All DS-206,
All DS-206,
All DS-206,
All DS-416,
All DS-416,
DS-420
DS-632
DS-632
DS-632
DS-632
DS-840
DS-840
DS-850

Breaker Types
all DS-416, and
all DS-416, and
all DS-416, and
all DS-416, and
all DS-416, and
all DS-416, and
all DS-416, and
and DS-420
and DS-420

all
all
all
all
all
all
all

DS-420
DS-420
DS-420
DS-420
DS-420
DS-420
DS-420

Breaker Frame Rating


800
800
800
800
800
800
800
1600
1600
2000
3200
3200
3200
3200
4000
4000
4000

DS-206 Spacer Kit (For DS-206 only. Not required for DS-206E, DS-206H or DS-206S)

Style Number
151D995G01
151D995G15
151D995G02
151D995G03
151D995G04
151D995G06
151D995G08
151D995G12
151D995G16
151D995G20
151D995G23
151D995G24
151D995G31
151D995G32
588C734G02
588C734G01
588C734G03

794A965G01

These are replacements for sensors style 794A170G _ _ series, and are for phase or neutral use except as noted.
For neutral use only.
For phase use only.
For DS-840 only.
For use with forced air cooled.
Kit includes 2 spacers.

Refer to Instruction Book 33-790-1G, page 63 table 4 for application of sensors.

October, 1996

Renewal Parts Data

33-790-1H
Page

21

CURRENT LIMITING BREAKERS

Isolating

Transformers

Current
Limiters

Blown
Limiter
Indicators
Figure 21.1
DSL-416

Description
Blown Limiter Indicator Assy
Blown Limiter Indicator Assy
(For fuse truck)
Isolating
Transformer
Assy
Isolating
Transformer
Only

Front View

No. Required
Per Breaker
1
1
1
3

Style
Number
140D777G01
140D777G03
591C755G01
795A823H01

Figure 21.2
DSL-416 w/o barriers

Current Limiters
Breaker
No. Required
Type
Per Breaker
DSL-206
3
DSL-206
3
DSL-206
3
DSL-206
3
DSL-206
3
DSL-206
3
DSL-206
3
DSL-206
3
DSL-206
3
DSL-206
3
DSL-416
3
DSL-416
3
DSL-416
3
DSL-416
3
DSL-416
3
DSL-416
3
DSL-416
3
DSL-420
3

Rear View

Amp
Rating
150
200
250
300
400
600
800
1200
1600
2000
800
1000
1200
1600
2000
2500
3000
3000

Drawout Fuse Truck Type Current Limiters


Truck
No. Required
Amp
Type
Per Breaker
Rating
DSL-3200
3
2500
3
3000
3
4000
DSL-4000
3
2500
3
3000
3
4000
3
5000
Includes 3 transformers.
Limiters are mounted on a separate fuse truck.
Refer to Instruction Book 33-790-1G, page 69 table 5

October, 1996

for application of limiters.

Style
Number
140D316G01
140D316G02
140D316G03
140D316G04
140D316G05
140D316G06
140D316G07
140D316G10
140D316G11
140D316G12
151D932G01
151D932G02
151D932G03
151D932G04
151D932G05
151D932G09
151D932G10
151D932G10
Style
Number
5980C01G01
5980C01G02
5980C01G03
5980C01G01
5980C01G02
5980C01G03
5980C01G04

Renewal Parts Data

33-790-1H
Page

22

SWITCHGEAR CELL PARTS


Divider Panel Kits
Between the circuit breakers in switchgear
are divider panels which usually hold a
variety of components for breaker control
and metering. The most common
components are ammeter, ammeter
switch, kirk key interlock, and electrically
operated pushbuttons and lights.
Standard voltage is 120VAC.
Each kit is pre-assembled, pre-wired and
comes with hardware and instructions for
ease of installation.
The kits shown on this page apply to the
DS circuit breakers listed below. For
circuit breakers not listed, contact your
local Cutler-Hammer distributor.
Breaker Type
Frame Size
DS-206
800
DS-206S,H
800
DSL-206
800
DS-416
1600
DS-416S,H
1600
DSL-416
1600
DS-420
2000

Figure 22.1
Divider Panel with ammeter, current
transformer and shorting block

Figure 22.2
Divider Panel with ammeter, switch,
pushbuttons, lights, current transformers
and shorting block

Figure 22.3
Divider Panel with ammeter, switch,
2-current transformers and shorting block

Figure 22.4
Divider Panel with ammeter, switch,
pushbuttons, lights, 2-current
transformers and shorting block

Figure 22.5
Divider Panel with ammeter, switch,
3-current transformers and shorting block

Figure 22.6
Divider Panel with ammeter, switch,
pushbuttons, lights, 3-current
transformers and shorting block

Figure 22.7
Divider Panel with pushbuttons and lights

October, 1996

Renewal Parts Data

33-790-1H
Page

23

SWITCHGEAR CELL PARTS


Divider Panel Kits
Description
Divider Panel with
Ammeter,
Current
Transformer
and
Shorting
Block

Divider Panel with


Ammeter,
Pushbuttons,
Lights,
Current
Transformer
and
Shorting
Block

Divider Panel with


Ammeter,
Switch,
2-Current
Transformers
and Shorting Block

October, 1996

Figure
Ammeter
Number Scale
22.1
0-100
22.1
0-150
22.1
0-200
22.1
0-300
22.1
0-400
22.1
0-500
22.1
0-600
22.1
0-800
22.1
0-1000
22.1
0-1200
22.1
0-1500
22.1
0-1600
22.1
0-2000
22.2
0-100
22.2
0-150
22.2
0-200
22.2
0-300
22.2
0-400
22.2
0-500
22.2
0-600
22.2
0-800
22.2
0-1000
22.2
0-1200
22.2
0-1500
22.2
0-1600
22.2
0-2000
22.3
0-100
22.3
0-150
22.3
0-200
22.3
0-300
22.3
0-400
22.3
0-500
22.3
0-600
22.3
0-800
22.3
0-1000
22.3
0-1200
22.3
0-1500
22.3
0-1600
22.3
0-2000

Style
Number
3A73104G01
3A73104G02
3A73104G03
3A73104G04
3A73104G05
3A73104G06
3A73104G07
3A73104G08
3A73104G09
3A73104G10
3A73104G11
3A73104G12
3A73104G13
3A73112G01
3A73112G02
3A73112G03
3A73112G04
3A73112G05
3A73112G06
3A73112G07
3A73112G08
3A73112G09
3A73112G10
3A73112G11
3A73112G12
3A73112G13
3A73106G01
3A73106G02
3A73106G03
3A73106G04
3A73106G05
3A73106G06
3A73106G07
3A73106G08
3A73106G09
3A73106G10
3A73106G11
3A73106G12
3A73106G13

Description
Divider Panel with
Ammeter,
Switch,
Pushbuttons,
Lights,
2-Current
Transformers
and Shorting Block

Divider Panel with


Ammeter,
Switch,
3-Current
Transformers
and Shorting Block

Divider Panel with


Ammeter,
Switch,
Pushbuttons,
Lights,
3-Current
Transformers,
and Shorting Block

Divider Panel with


Pushbuttons and Lights

Figure
Ammeter
Number Scale
22.4
0-100
22.4
0-150
22.4
0-200
22.4
0-300
22.4
0-400
22.4
0-500
22.4
0-600
22.4
0-800
22.4
0-1000
22.4
0-1200
22.4
0-1500
22.4
0-1600
22.4
0-2000
22.5
0-100
22.5
0-150
22.5
0-200
22.5
0-300
22.5
0-400
22.5
0-500
22.5
0-600
22.5
0-800
22.5
0-1000
22.5
0-1200
22.5
0-1500
22.5
0-1600
22.5
0-2000
22.6
0-100
22.6
0-150
22.6
0-200
22.6
0-300
22.6
0-400
22.6
0-500
22.6
0-600
22.6
0-800
22.6
0-1000
22.6
0-1200
22.6
0-1500
22.6
0-1600
22.6
0-2000
22.7
N/A

Style
Number
3A73113G01
3A73113G02
3A73113G03
3A73113G04
3A73113G05
3A73113G06
3A73113G07
3A73113G08
3A73113G09
3A73113G10
3A73113G11
3A73113G12
3A73113G13
3A73107G01
3A73107G02
3A73107G03
3A73107G04
3A73107G05
3A73107G06
3A73107G07
3A73107G08
3A73107G09
3A73107G10
3A73107G11
3A73107G12
3A73107G13
3A73114G01
3A73114G02
3A73114G03
3A73114G04
3A73114G05
3A73114G06
3A73114G07
3A73114G08
3A73114G09
3A73114G10
3A73114G11
3A73114G12
3A73114G13
3A73115G01

Renewal Parts Data

33-790-1H
Page

24

SWITCHGEAR CELL PARTS


Neutral Sensor Kit
The Neutral Sensor Kit (Figure 24.1)
includes a fourth sensor and mounting
hardware for four wire ground fault
protection. Additional wiring needs to be
done to the DS circuit breaker. (If there is
no ground fault protection on the existing
DS circuit breaker, then the trip unit also
needs to be changed).

Neutral Sensor Kit


Sensor
Figure
Ampere Rating Number
50
24.1
100
24.1
150
24.1
200
24.1
300
24.1
400
24.1
600
24.1
800
24.1
1200
24.1
1600
24.1
2000
24.1

A kit contains 1 neutral sensor, mounting


plate and hardware.

Style
Number
3A73101G01
3A73101G02
3A73101G03
3A73101G04
3A73101G05
3A73101G06
3A73101G07
3A73101G08
3A73101G09
3A73101G10
3A73101G11

Figure 24.1
Neutral Sensor Kit

3-Phase Current Transformer Kit


Figure 24.2 is a 3-phase current transformer that takes the guess work out of
wiring. Included in the kit along with the
transformer is a new glass polyester
barrier and the required hardware. This can
be used instead of the individual current
transformers (Figure 25.4) for metering and
instrumentation ONLY. This kit is applicable for the following circuit breakers
ONLY: DS-206, DS-206H, DS-206S,
DSL-206, DS-416, DS-416S, DS-416H,
DSL-416, and DS-420.

3-Phase Current Transformer Kit


Ratio
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5

Figure
Number
24.2
24.2
24.2
24.2
24.2
24.2
24.2
24.2
24.2
24.2
24.2
24.2

Style
Number
3A73102G01
3A73102G02
3A73102G03
3A73102G04
3A73102G05
3A73102G06
3A73102G07
3A73102G08
3A73102G09
3A73102G10
3A73102G11
3A73102G12

Figure 24.2
3-Phase Current Transformer Kit
Key Interlock Provision Kit
The key interlock provision kit (Figure 24.3)
includes all the necessary hardware to
complete a provision for all DS circuit
breakers. Included in the kit is a new
divider panel and blank plates to accept a
key interlock. (2cylinders max.)

Key Interlock Provision Kit


Breaker
Figure
Type
Number
DS-206, DS-206S
24.3
DS-206H,
DS-206E
DSL-206, DS-416,
DS-416S,
DS-416H,
DSL-416,
DS-420
DS-632,
24.3
DS-632 with fuses
DS-840,
24.3
DS-840 with fuses

Style
Number
3A73116G01

3A73116G02
3A73116G03

Figure 24.3
Key Interlock Provision Kit

October, 1996

Renewal Parts Data

33-790-1H
Page

25

SWITCHGEAR CELL PARTS

Figure 25.1
125VDC Capacitor Trip Device
(For use in 120VAC
control circuits)
Catalog Number (330mfd.)
CTD-1
Catalog
Number
(1500mfd.)
CTD-2
Current Transformer Kit
The
current transformers shown in Figure
25.4 are for metering and instrumentation
ONLY. Do not use these current transformers for relaying. A kit contains three current
transformers and the required hardware.

Figure 25.4
Current Transformer Kit

Figure 25.2
Stationary Secondary Contact (8 Point)
Style
Number
590C808G01

Current Transformer Kit


Circuit Breaker
Type
Type
DSM-16
DS-206, DS-206S
DS-206H,
DS-206E
DSL-206,
DS-416,
DS-416S,
DS-416H,
DSL-416,
DS-420

DSM-32

DS-632,
DS-632 with fuses

DSM-40

DS-840,
DS-840 with fuses

Figure 25.3
Breaker Cell Switch
3-NO, 3-NC Style Number
6-NO, 6-NC Style Number

Ratio
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
2500:5
3000:5
2400:5
2500:5
3000:5
3200:5
4000:5
4000:5
5000:5
6000:5

2A89010G01
2A89010G02

Figure
Number
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4

Style
Number
3A73103G01
3A73103G02
3A73103G03
3A73103G04
3A73103G05
3A73103G06
3A73103G07
3A73103G08
3A73103G09
3A73103G10
3A73103G11
3A73103G12
3A73103G13
3A73103G14
3A73103G15
3A73103G16
3A73103G17
3A73103G18
3A73103G19
3A73103G20
3A73103G21
3A73103G22
3A73103G23
3A73103G24

Figure
Number
25.5
25.5
25.5

Style
Number
140D294H02
140D769H01
140D768H01
(Not
available)

Insulation Boot For Live Bus Stab


Description
All breakers except DS-632 and DS-840
DS-632 (For cells w/o CTs)
DS-632 (For cells w/ CTs)
DS-840
Figure 25.5
Insulation Boot for Live Bus Stab

October, 1996

Required 1 for each stab.

Renewal Parts Data

33-790-1H
Page

26

ACCESSORIES and OTHER PARTS


DSL-XXX

Figure 26.1
Replacement Nameplate (DSL Shown)

Figure 26.2
DS Breaker Label Kit
Style
Number

Figure 26.5
Lifting Yoke (Spreader Bar)
Style
Number

Retaining

Truarc
Figure 26.4
Portable Lifter
Style
Number

6727D63H20

Ring

Ring

Figure 26.7
Fastener Kit
Style
Number

Std

8187A84G01

Figure 26.3
DSL Breaker Label Kit
Style
Number

3831A07G01

694C614G02

Figure 26.6
Levering-In Tool
Style
Number

8644C73G01

Figure 26.8
Finger Cluster Removal Tool
Style
Number

591C901G01

'E'

Washer

Ring

3586A86G01

Each kit includes 84 fasteners in various sizes and quantities of the types shown in
Figure 26.7.
October, 1996

Renewal Parts Data

33-790-1H
Page

27

ACCESSORIES and OTHER PARTS

Figure 27.1
Space Heater

Figure 27.2
Breaker Test Kit and Adapter
Style
Number
8779C02G02

Description
Replacement

Space

Nameplate

Use
Used to replace the nameplates on the
front of the breaker

Heater

27.1

To
is

Secondary
Disconnect
Contact
Secondary
Disconnect
Contact
Cover
Secondary
Disconnect
Mounting Frame with
8 point contact block
Drawout
Breaker
Front Covers for
Amptector
or
Digitrip Box

2.3

For

2.3

Covers

2.3
2.3

For replacing secondary dicsonnect mounting


frame, or for adding to breaker originally
supplied without secondary contacts
Covers Front of Breaker

Drawout
Breaker
Front Covers for
Digitrip II and
Digitrip III

2.3

Covers Front of Breaker

Escutcheon

2.1

Mounts on front cover

2.3

To roll the breaker in and out of the housing


(Set of four)

2.3

Guides

Plate

Breaker Roller Kit


(double edge type)
and Retaining Rings
Wiring Guide Kit

Figure
Number
26.1

reduce condensation
de-energized

Disconnecting
top

for

of

secondary

secondary

wiring

when

the

switchgear

control

contacts

Figure 27.3
Test Kit Adapter
Style
Number

Application
DS
Dummy
DS Drawout
DSL
Fuse Truck
DS Fixed
250 Watts, 125 Volts
250 Watts, 250 Volts
375 Watts, 125 Volts
375 Watts, 250 Volts
95 Watts, 125 Volts
100 Watts, 250 Volts
All Breakers

Style
Number
9194D95H61
9194D95H63
9194D95H64
9194D95H65
9194D95H67
7497A69H01
7497A69H02
7497A69H03
7497A69H04
7497A69H04
7497A69H05
591C498G06

All

Breakers

503B569H01

All

Breakers

591C498G07

All DS except DS-632


and DS-840
DS-632
DS-840
DSL-206 and DSL-416
DSL-420
All DS except DS-632
and DS-840
DS-632
DS-840
DSL-206 and DSL-416
DSL-420
All DS Breakers
All DSL Breakers
All Breakers

694C733H02
695C105H01
695C106H01
694C733H02
695C147H02
695C102H01
695C103H01
1A33578G01

All DS except DS-840


DS-840
All DSL Breakers

1A33588G01
151D418G01
1A33589G01

Customer is to provide the following original information: GO, P.O., Item, FN and Option numbers.

October, 1996

8779C02G03

567F498H01
567F499H01
567F503H02
567F498H03
695C166H02

Renewal Parts Data

33-790-1H
Page

28

SWITCHGEAR CELL PROVISIONS and UPGRADES


If the original switchgear has blank compartments or if an existing breaker needs to be upgraded, cell parts can be ordered.
typically include some or all of the following parts:
Mounting pan, extension rails, and push-to-trip mechanism
Interference brackets
Polyester backplate (CT mounting plate)
Line and load stabs
Load bus runbacks, extensions, supports, and lug adapters
Door with handle, hinge and trip button
Gas and arc shields
Seismic positioner
Contact

your local Cutler-Hammer sales


General Order number
Shop Order number
Date of manufacture

representative

with

the

following

They

information:

RECOMMENDED SPARE PARTS FOR STOCK


The quantities listed are recommended for 5 breakers of the same rating. Items 8 -10 are only required for electrically operated breakers.
The reference page number contains the complete styles of the required parts. Where needed, fill in or complete the style numbers for
your application and forward to your local Cutler-Hammer sales representative.

Item
1
2
3
4
5
6
7
8
9
10
11

Qty
1
1
1
1
1
1
1
1
1
1
1

Cutler-Hammer
Westinghouse
&
Cutler-Hammer
Products
Power
Distribution
Components
Pittsburgh, Pennsylvania, U.S.A.

Description
Pole Unit Assembly
Main Disconnect Contact Assembly
Trip Shaft Kit
Direct Trip Actuator (DTA)
Opening
Spring
Fastener Kit
Secondary
Disconnect
Contact
Shunt Trip Assembly
Spring
Release
Assembly
Anti-Pump
Relay
Spring Charge Motor Kit

Kit

Reference
Page
Number
4-7
10
13
17
13
26
27
15
15
15
15

Style
Number
1A33570G_ _
1A33576G01
6482C55G _ _
698B907H01
3586A86G01
591C498G06
3752A _ _G0 _
3752A _ _G0 _
8293A05G _ _
449D431G0 _

Division
15220

Printed in U.S.A.

October, 1996

Vous aimerez peut-être aussi