ABSTRACT
Hydraulic calculations for treated water mains are performed in steady state considering a
demanded flow. Checks pressures coming from transients are made in order to predict
protection devices, preventing or mitigating the effects of sudden pressure change in the piping.
In pumping systems of treated water, these schemes are a regular and frequent event, which
accompany any change in their normal operating conditions such as variations in flow demand
and network extensions, which can result in surge or water hammer. The most violent
circumstances associated with the water hammer usually result of power failure of a pumping
station with consequent interruption of the same. This work aims to check discharge system
tracing, with the help of geographic information system - GIS, as well as its design to suit a
region of the city of Cuiab, with subsequent computer simulation for verification of the
transitional arrangements of the proposed system using Allievi the software.
Key words: Dimensioning, under pressure flow, Water supply, Hydraulic transient, Water
hammer, Hydraulic simulation.
ACRNIMOS E SIGLA
SAA
ETA
EEAB
EEAT
CMB
ADT
Adutora
RAP
Reservatrio Apoiado
REL
Reservatrio Elevado
RUD
Reservatrio Unidirecional
RHO
Reservatrio Hidropneumtico
SRTM
SMDU
IBGE
SUMRIO
INTRODUO ...................................................................................................................... 13
OBJETIVOS ........................................................................................................................... 15
OBJETIVO GERAL.............................................................................................................. 15
OBJETIVOS ESPECFICOS ................................................................................................ 15
1
FUNDAMENTAO TERICA.................................................................................. 16
1.1 SISTEMA DE ABASTECIMENTO DE GUA ............................................................ 16
1.1.1 MANANCIAL .................................................................................................... 17
1.1.2 CAPTAO ....................................................................................................... 17
1.1.3 ESTAO ELEVATRIA ................................................................................ 17
1.1.4 ADUTORA ......................................................................................................... 17
1.1.5 ESTAO DE TRATAMENTO DE GUA ..................................................... 17
1.1.6 RESERVATRIO DE DISTRIBUIO DE GUA ........................................ 18
1.1.7 REDE DE ABASTECIMENTO DE GUA ...................................................... 18
1.1.8 LIGAO DOMICILIAR .................................................................................. 18
1.2 HIDRULICA DE CONDUTOS FORADOS ............................................................ 19
1.2.1 EQUAO DA ENERGIA ................................................................................ 19
1.2.2 EQUAO DA CONTINUIDADE ................................................................... 20
1.2.3 TEOREMA DO TRANSPORTE DE REYNOLDS ........................................... 20
1.2.4 PERDA DE CARGA .......................................................................................... 22
1.3 ADUTORAS ................................................................................................................... 26
1.3.1 CANALIZAO DE RECALQUE ................................................................... 27
1.3.2 MATERIAIS DOS CONDUTOS ....................................................................... 31
1.4 TRANSITRIO HIDRULICO .................................................................................... 33
1.4.1 MECANISMO DO FENMENO ...................................................................... 35
1.4.2 VERIFICAO DE REGIMES TRANSITRIOS ........................................... 37
1.4.3 MTODOS DE ANLISE ................................................................................. 40
METODOLOGIA ........................................................................................................... 52
2.1 REA DE ESTUDO ....................................................................................................... 53
2.2 TOPOGRAFIA ............................................................................................................... 55
2.3 POPULAO ATENDIDA ........................................................................................... 56
2.4 CANALIZAO DE RECALQUE ............................................................................... 57
2.5 VERIFICAO DE TRANSIENTE .............................................................................. 58
LISTA DE ILUSTRAES
FIGURA 1 - ESQUEMA SISTEMA DE ABASTECIMENTO DE GUA. .......................... 16
FIGURA 2 - ENERGIA TOTAL E PERDA DE ALTURA NO FLUXO DE UM TUBO. .... 19
FIGURA 3 - EXPERIMENTO DE REYNOLDS. ................................................................... 21
FIGURA 4 - ADUTORA POR GRAVIDADE E RECALQUE. ............................................. 26
FIGURA 5 - VAZES A SEREM VEICULADAS NAS ADUTORAS. ................................ 27
FIGURA 6 - DETERMINAO DO DIMETRO ECONMICO. ...................................... 29
FIGURA 7 - SOLUES PARA NICO RECALQUE. ........................................................ 31
FIGURA 8 - TRANSIENTE HIDRULICO NA POSIO DO X DO SISTEMA. ............. 33
FIGURA 9 - TRANSIENTE HIDRULICO EM EEAT. ....................................................... 34
FIGURA 10 - PROPAGAO DE ONDA DE PRESSO .................................................... 35
FIGURA 11 - ONDAS DE PRESSO COM E SEM PERDA DE CARGA. ......................... 36
FIGURA 12 - FLUXOGRAMA PARA O CONTROLE DE SURTOS EM SISTEMAS DE
DISTRIBUIO. ..................................................................................................................... 38
FIGURA 13 - SEPARAO DE COLUNAS LIQUIDAS. .................................................... 39
FIGURA 14 - DIAGRAMA DE SOBREPRESSO. .............................................................. 41
FIGURA 15 - ANALISE PRELIMINAR DAS ENVOLVENTES DE PRESSO. ................ 41
FIGURA 16 - VOLANTE DE INRCIA. ............................................................................... 47
FIGURA 17 - VENTOSA DE DUPLA FUNO. ................................................................. 48
FIGURA 18 - BACO DE SELEO DE VENTOSAS DUPLA FUNO........................ 49
FIGURA 19 - CROQUI ESQUEMTICO - RHO. ................................................................. 50
FIGURA 20 - RESERVATRIO UNIDIRECIONAL (RUD). ............................................... 51
FIGURA 21 - FLUXOGRAMA PARA OBTENO DOS RESULTADOS. ....................... 52
FIGURA 22 - LOCALIZAO DE CUIAB-MT................................................................. 53
FIGURA 23 - ETA RIBEIRO DO LIPA (RAP MONTANTE). ........................................... 53
FIGURA 24 - RESERVATRIO JARDIM BOM CLIMA (RAP JUSANTE). ...................... 54
FIGURA 25 - REA DE ESTUDO. ........................................................................................ 54
FIGURA 26 EARTH EXPLORE, USGS. ............................................................................. 55
FIGURA 27 - QGIS 2.8.6 - WIEN. .......................................................................................... 56
FIGURA 28 SUBSISTEMA RIBEIRO DO LIPA. ............................................................ 57
FIGURA 29 - DENSIDADE DEMOGRFICA POR BAIRRO. ............................................ 57
FIGURA 30 - SOFTWARE ALLIEVI. .................................................................................... 58
FIGURA 31 - CATALOGO IMBIL V 3.0 ............................................................................... 59
13
INTRODUO
Sistemas de abastecimento de gua (SAA) so constitudos de captao de gua em
manancial (superficial e/ou subterrneo); estaes de tratamento; adutoras; reservatrios e redes
de distribuio. As concepes destes sistemas dependem, de modo geral, do tipo de manancial,
da topografia e populao a ser atendida.
A gua captada no manancial, transportada por meio de adutoras de gua bruta (AB)
para as estaes de tratamento de gua onde passar, em um sistema convencional, pela mistura
rpida, floculao, decantao, filtrao e desinfeco, a fim de atingir a qualidade exigida na
portaria de potabilidade. A gua tratada encaminhada para reservatrios, em seguida aduzida
ao sistema de distribuio por adutoras de gua tratada, que em geral conectam reservatrios
ou s redes de distribuio, por onde a gua chega populao.
As adutoras podem ser classificadas quanto a energia para movimentao da gua em:
adutoras por gravidade, por recalque, mistas. Em adutoras por gravidade a energia disponvel
a diferena geomtrica entre montante e jusante, o escoamento pode ser em regime forado ou
livre. As adutoras por recalque transportam gua de um ponto baixo para outro alto, para vencer
esta diferena geomtrica e a perda de carga necessrio fornecer energia ao fludo atravs de
motores e bombas, que transformam energia eltrica em energia de presso, impulsionando
gua para jusante e esta unidade chamada de estao elevatria de gua. As adutoras mistas
so a juno das duas anteriores.
Na primeira fase de um projeto de adutora considerado o regime permanente, ou seja,
a vazo e presso so constantes ao longo do tempo, assim como as demandas (consumo). Na
segunda etapa deve-se considerar que o sistema de aduo dinmico, sujeito a variaes de
consumo e quedas no fornecimento de energia eltrica, por exemplo. As variaes neste regime
podem dar origem ao fenmeno de transiente hidrulico, este que deve ser verificado a fim de
evitar situaes indesejveis como, sobrepresses, subpresses, fluxo inverso, deslocamento de
tubulaes, peas e rompimentos.
A anlise de transitrio hidrulicos subsidia avaliar pontos crticos do perfil de sua rede,
onde as presses podem ser excessivamente elevadas, atingindo valores muito maiores que a
presso mxima de servio da tubulao ou muito baixas, atingindo a presso de vapor do
fludo. Para amortizar os efeitos deste regime transitrio, so instaladas ao longo do perfil da
aduo e/ou nas EEAT dispositivos de proteo, tais como: vlvulas de ar (ventosas), vasos de
presso, chamins de equilbrio, volantes de inrcia e inversores de frequncia.
14
Para elaborao deste trabalho supe-se uma estao elevatria, elevando gua tratada
de uma estao de tratamento de gua at um reservatrio apoiado, localizados na cidade de
Cuiab, Mato Grosso, a fim de atender uma populao estimada.
No captulo primeiro, sero apresentados os conceitos bsicos de sistema de
abastecimento de gua e seus componentes fsicos, seguido das principais equaes utilizadas
no dimensionamento de adutoras e verificao de transitrios hidrulicos.
Na segunda parte do captulo primeiro dado foco as adutoras, quanto a sua
classificao, seleo de traado, materiais, dimensionamento e condies operacionais.
Seguido do assunto transitrios hidrulicos, suas causas e efeitos, assim como os principais
dispositivos de proteo. A reviso foi elaborada a partir de livros, artigos cientficos,
dissertaes de mestrado e doutorado alm de manuais tcnicos relacionados aos temas de
abastecimento de gua, projeto, execuo de redes e transitrios hidrulicos.
O segundo captulo dedicado a descrio da metodologia adotada para o
desenvolvimento deste trabalho, da obteno de imagens de satlite, utilizao de ferramenta
SIG e descrita a rea de estudo e demais procedimentos aplicados para obteno dos dados
necessrios para dimensionamento da adutora e a avaliao de transitrio hidrulico.
15
OBJETIVOS
OBJETIVO GERAL
Pr-dimensionamento hidrulico de adutora sob presso, supondo que eleve gua tratada
de um reservatrio, localizado em uma estao de tratamento de gua, a outro reservatrio
apoiado (RAP), ambos na cidade de Cuiab, com simulao computacional de transitrio
hidrulico.
OBJETIVOS ESPECFICOS
Obteno de cenas SRTM, com extrao de curvas de nvel, utilizando o software
QGIS;
Seleo do traado da linha de aduo, utilizando sistema de informao geogrficas
(SIG);
Pr-dimensionamento hidrulico do recalque;
Verificao preliminar de transitrio hidrulico por mtodo expedito;
Simulao computacional de transitrio hidrulico do sistema sem proteo,
utilizando o software ALLIEVI e diagnstico.
16
Captulo 1
1
FUNDAMENTAO TERICA
Na primeira parte deste captulo sero apresentados os conceitos bsicos de sistema de
abastecimento de gua abordando seus componentes fsicos. Seguido de uma reviso concisa
de hidrulica de condutos forados, apresentando as principais equaes utilizadas no
dimensionamento de adutoras e verificao de transitrios hidrulicos. Na segunda parte
abordado o tema adutoras, com nfase nas canalizaes de recalque, que constituem o objetivo
deste trabalho. A terceira parte dedicada ao assunto: Transitrio Hidrulico, sua definio, as
causas e efeitos, assim como os dispositivos de proteo. A reviso foi elaborada a partir de
livros, dissertaes de mestrado e doutorado, artigos cientficos alm de manuais tcnicos
relacionados aos temas de abastecimento de gua, projeto, execuo de redes.
1.1
voltados para o suprimento de gua a comunidades, para fins de consumo domstico, industrial
e pblico. Este sistema constitui-se basicamente da captao de gua de algum manancial, do
seu tratamento e posterior distribuio aos consumidores. Abaixo sero descritos os principais
componentes fsicos que constituem um Sistema de Abastecimento de gua convencional, so
eles:
FIGURA 1 - ESQUEMA SISTEMA DE ABASTECIMENTO DE GUA.
17
1.1.1 MANANCIAL
Local onde a gua captada para o abastecimento, pode ser de uma fonte subterrnea
ou superficial e deve ser suficiente para atender a demanda de projeto (TSUTIYA, 2006).
1.1.2 CAPTAO
o conjunto de obras necessrias para retirar a gua do manancial. Quando a fonte
um manancial de guas superficiais esta unidade em geral composta por gradeamento para
reteno de materiais grosseiros e desarenador para retirada da areia presente na gua, as obras
so de acordo com o porte dos mananciais, topografia, geologia do local e da velocidade,
qualidade e variao do nvel da gua (DACACH, 1979). O projeto e construo das obras de
captao devem assegurar condies de fcil entrada da gua e da melhor qualidade possvel.
18
19
1.2
da atmosfrica. Para Stephenson (1989) as trs mais importantes equaes na mecnica dos
fludos so as: i) equao da continuidade; ii) equao da conservao da quantidade de
movimento e iii) equao conservao de energia. O teorema de transporte de Reynolds a
base utilizada na formulao das leis bsicas da dinmica dos fluidos, inumeradas por
Stephenson. Na fsica elas so conhecidas respectivamente por lei da conservao da
massa, segunda lei de Newton e leis da termodinmica.
+ +
2
(0)
20
(1)
Na figura 2 a sigla EGL representa a linha de energia do sistema ou linha de carga, que
pode ser obtida ligando todos os pontos de energia total do sistema. A inclinao desta linha
representa a taxa na qual a energia perdida ao longo do tubo. A uma distncia V/2g abaixo
da EGL temos a linha hidrulica ou linha piezomtrica HGL do ingls hydraulic grade line.
A projeo horizontal de a at a chamada de plano de carga, energia esttica do sistema
(Adaptado de HOUGHTALEN, 2012).
(2)
2
= |A=
(3)
Onde:
V
21
de vazo efluente, fora aberta vagarosamente de modo a permitir que a taxa de escoamento no
tubo aumentasse gradualmente, inicialmente observou-se que o corante surgiu como um
pequeno fio estendendo-se no sentido do fluxo, indicando fluxo laminar, at que se atingisse
uma determinada velocidade, ento o fio se rompeu misturando-se a gua, caracterizando o
regime de escoamento turbulento (Adaptado de HOUGHTALEN, 2012).
| =
(4)
Onde:
Re Nmero de Reynolds
Viscosidade cinemtica
D Dimetro do tubo
Viscosidade absoluta
V Velocidade do fludo
Densidade do fludo
22
= ( )
2
(5)
Onde:
hf perda de carga (m)
coeficiente de atrito
comprimento da canalizao
O fator de atrito utilizado no clculo da perda de altura, na frmula universal pode ser
obtido atravs das equaes:
i.
Colebrook-White
Existem numeras formulas que relacionam o coeficiente de atrito (f) com o nmero
Reynolds (Re) e rugosidade. Uma das mais populares equaes a de Colebrook-White,
apresentada em 1939, na seguinte formulao:
1
2,51
= 2 log (
+
)
3,71
(6)
23
ii.
Swamee-Jain
1,325
5,74 2
[ln (3,7 + 0,9 )]
(7)
Pela sua relativa simplicidade e relativa preciso, maioria dos softwares de modelagem
de sistemas hidrulicos utilizam esta formula para determinao do fator de atrito nas
canalizaes (KOELLE, 2003, traduo nossa).
Em problema de conduo de gua, que pela sua importncia exija avaliao das perdas
de cargas to rigorosas quanto possvel, diante da incerteza sobre o tipo de escoamento
turbulento, deve-se utilizar a formula universal, com fator de atrito determinado pela equao
de Colebrook-White ou Swamee-Jain (PORTO, 2006).
A especificao da rugosidade da tubulao e a previso de suas modificaes com o
tempo, devido a alterao da superfcie da parede, muitas vezes causadas pela prpria qualidade
da gua, coloca o projetista diante do problema difcil de determinar os fatores de atrito da
tubulao (PORTO, 2006).
24
25
b) Hazen-Willians
Dentre as formulas empricas mais utilizadas, principalmente na prtica da engenharia
sanitria americana, encontra-se a de Hazen-Williams. Os seus limites de aplicao so os mais
largos: dimetro de 50 a 3500 mm e velocidades de at 3 m/s, sua expresso pode ser escrita:
= 10,643 1,85 1,85 4,87
(8)
Onde:
J
Q vazo (m/s)
coeficiente de rugosidade
Esta formula pode ser aplicada a condutos livre ou forados; tem sido empregada para
canalizaes de gua e esgoto. Seus autores basearam-se em experincias com os seguintes
materiais (tubos): ao, cimento, chumbo, estanho, ferro forjado, ferro fundido, lato, madeira,
tijolos e vidro. O coeficiente C depende da natureza, do material, estado da parede do tubo e de
sua idade (NETTO, 1998).
A sua aplicao recomendada, preliminarmente, para:
26
1.3
ADUTORAS
O termo adutora empregado para designar as canalizaes que transportam gua entre
27
(9)
Onde:
Q vazo da adutora que interliga a ETA ao RAP (L/dia)
K11 coeficiente do dia de maior consumo
Relao entre o valor do consumo mximo dirio ocorrido em um ano e o consumo dirio relativo a esse ano;
28
d) Seleo do traado
A NBR 12215 estabelece que em reas urbanas o conduto deve ficar condicionado ao
sistema virio existente ou planejado, instalada de preferncia em faixas de domnio pblico,
caso no seja possvel deve-se prever a desapropriao da faixa ou instituio de servido sobre
ela, ressaltando que esta deve ter largura suficiente para permitir a execuo de eventuais
manutenes. O conduto deve ser composto de trechos ascendentes com declividade maior que
0,2% e descendentes no inferior a 0,3%, mesmo em terrenos planos.
Para o estudo de concepo do sistema necessrio dispor dos pontos de origem e
trmino da adutora, assim como dos elementos topogrficos necessrio para determinao do
caminhamento da linha de aduo, este devendo ser definido com base em critrios tcnicos e
econmicos, comparando-se caminhamentos alternativos a partir das plantas topogrficas. Para
o traado do conduto deve-se:
Evitar regies: pantanosas, reas submersas e reas com declividade elevada;
Evitar interferncia: em complexos industriais e instalaes aeroporturias;
A mesma normativa recomenda que no traado de adutoras em condutos forados, os
trechos ascendentes sejam longos com pequena declividade, seguidos de trechos descendentes
curtos e com maior declividade, para favorecer o acumulo de eventual vapor nestes pontos,
podendo assim ser expurgados por vlvulas especificas.
O traado da adutora feito normalmente em funo das caractersticas topogrficas do
terreno. Entretanto outros aspectos devem ser considerados para o traado, tais como: a
influncia do plano de carga e da linha piezomtrica, localizao e perfil da adutora faixas de
servido ou desapropriao para implantao e operao das adutoras. A linha piezomtrica da
adutora em regime permanente deve situar-se em quaisquer condies de operao, sempre
acima da geratriz superior do conduto (Adaptado de TSUTIYA, 2006).
e) Dimensionamento
Enquanto as adutoras por gravidade admitem uma nica soluo para transporte da
vazo, nas adutoras por recalque o problema fica indeterminado, devido a possibilidade de se
adotar, teoricamente, qualquer dimetro, desde que associado corretamente ao equipamento de
recalque. A indeterminao do problema desaparece quando se considera os aspectos
econmicos da questo, ou seja, dentre os vrios dimetros possveis de atendimento adota-se
o mais econmico (SEG, 2008).
29
(10)
Onde:
D dimetro (m)
Q vazo (m/s)
K coeficiente de Bresse.
30
(11)
Onde:
V
coeficiente de Bresse.
Tsutiya (2006, p. 171) afirma que a velocidade econmica em adutoras por recalque
tem-se situado, de modo geral, entre 1,0 a 1,5 m/s.. O mesmo autor recomenda que na escolha
do dimetro econmico por este mtodo, deve utilizar, no mnimo, os valores de K de 0,9; 1,0;
1,1 e 1,2.
Segundo Leal (1995 apud Freire, 2000) os limites de velocidade mxima praticadas nos
dimensionamentos vm sendo extrapolados por diversos pesquisadores. A tendncia de
aumentar-se os valores recomendados est baseada em critrios empricos da experincia
pratica dos autores. Eles asseguram que os limites existentes so muito baixos e, objetivando
compatibilizar o custo da tubulao com a segurana do sistema, estabelecem novos limites
para as velocidades mxima do fluxo nas tubulaes em funo dos seus dimetros, dos custos
dos tubos e do risco de danos admitidos.
Para as adutoras recomenda-se como limite de velocidade nas tubulaes os valores da
tabela abaixo, em relao ao material da tubulao.
TABELA 3 - VELOCIDADE LIMITE PARA ADUTORAS (CETESB)
MATERIAL
Plsticos
Ferro fundido
Fibrocimento
Ao
Concreto
31
32
Fabricante
ABREVIATURA
PRP
PMC
PTR
PSA
PMS
PTA
PN
DESCRIO
Presso de clculo em regime permanente
Presso mxima de clculo
Presso de teste da rede
Presso de servio admissvel
Presso mxima de servio
Presso de teste admissvel
Presso nominal
PMC PMS
PTR PTA.
A PRP a presso mxima de servio, fixada pelo projetista, excluindo o golpe de arete.
J a PMC a presso mxima incluindo o golpe e ainda pode ser estimado (PMCe) ou calculado
(PMCc). Para o fabricante a PSA a presso interna que o tubo suporta, funcionando em regime
permanente, desconsiderando o golpe de arete, a PMS a presso interna mxima, incluindo
o golpe. A terminologia PN uma designao numrica de referncia, onde todos os materiais
desta classe so compatveis em presso admissvel e dimenses dos flanges.
33
1.4
TRANSITRIO HIDRULICO
O transitrio hidrulico definido por Koelle (2003) como sendo a condio de
escoamento e presso, entre um regime permanente inicial e outro final. Quando a velocidade
muda abruptamente devido a mudana de status de um componente de controle de fluxo (por
exemplo, um fechamento de registro ou parada de um bombeador), causa uma onda de presso,
que se move atravs do sistema at que se estabelea o novo regime permanente. Caso a
magnitude desta onda seja grande o suficiente e os dispositivos de proteo no estejam nos
lugares adequados, o transiente pode vir causar a falha dos componentes hidrulicos do sistema.
A evoluo de um transiente pode ser mostrada atravs de posies incrementais no
sistema, por meio de um grfico semelhante ao mostrado abaixo. Neste grfico, a presso (P)
representada em funo do tempo (t), resultante do fechamento de um registro. Na figura, 1
a presso inicial no incio do evento transiente, 2 a presso final no fim do evento, Pmin a
presso mnima transiente, e Pmax a presso mxima do transiente.
FIGURA 8 - TRANSIENTE HIDRULICO NA POSIO DO X DO SISTEMA.
Stephenson (1989) diz que as presses transitrias causadas por uma alterao na taxa
de fluxo nos condutos, so frequentemente a causa de rupturas nas tubulaes. A variao de
presso associada com uma parada repentina de vazo pode causar aumento de centenas de
metros de carga. Transientes em condutos forados so normalmente classificados em duas
categorias: i) Surtos, quando a oscilao de massa no fluido lenta; ii) Golpe de arete, quando
a mudana no fluido rpida acompanhando por uma deformao elstica no conduto.
34
35
(12)
H, ento a tendncia de gua sair para fora da tubulao, pela extremidade superior.
Como a extremidade inferior do tubo est fechada, haver uma depresso interna. Nessas
condies, -v convertida em uma onda de depresso.
36
9900
(13)
48,3 +
Onde:
C celeridade da onda (m/s)
D dimetro (m)
< (2 )/
Manobra lenta
> (2 )/
37
38
fenmeno transitrio, que eles mais temem que ocorram ao sistema hidrulico. As
consequncias podem ser quaisquer uma das relacionas abaixo:
Presso mxima no sistema;
Ocorrncia de vcuo e/ou cavitao;
Vibrao do conduto hidrulico em seus suportes e/ou rpida oscilaes fortes ou
movimento rpido de massas de gua;
Risco de ocorrncia de contaminao da gua (intruso).
FIGURA 12 - FLUXOGRAMA PARA O CONTROLE DE SURTOS EM SISTEMAS DE DISTRIBUIO.
39
40
(14)
41
Manobra rpida
= ( )/
(15)
Manobra lenta
= (2 )/
(16)
= +
=
(17)
(18)
42
programa
proporciona
condies
para
analisar
verificar
os
efeitos
43
(19)
Como este sistema no tem soluo analtica, para a integrao das equaes o
procedimento habitual transform-lo num sistema de equaes de diferenas finitas e
admitir que a soluo seja alcanada em instantes t sucessivos separados de um intervalo
t e em pontos x especficos (separados de uma distncia x) obedecendo a condio, sendo
"a" a celeridade:
(20)
As equaes diferenciais acima so transformadas em um sistema de duas equaes
algbricas, lineares com duas incgnitas, da forma:
(21)
44
45
PRESSO DE
VAPOR (Pa)
611
MASSA ESPECFICA
(kg/m)
999,80
VISCOSIDADE CINEMTICA
( m/s)
1,793
872
999,90
1,519
10
1.228
999,60
1,309
15
1.704
999,00
1,141
20
2.337
998,20
1,010
25
3.166
997,00
0,896
30
4.241
995,60
0,802
35
5.622
993,90
0,727
40
7.375
992,20
0,661
45
9.584
990,20
0,604
50
12.335
998,00
0,556
Para o estudo do golpe de arete, esta normativa prev a utilizao do mtodo das
caractersticas e da equao e tabelas apresentadas no anexo B, mostradas a seguir, para o
clculo da celeridade (a) de propagao de ondas de presso em condutos de parede fina.
1 +
(12)
46
Onde:
K mdulo de elasticidade volumtrico da gua;
E mdulo de elasticidade do material de que feito o conduto (Pa);
massa especfica da gua (kg/m);
e espessura da parede do conduto (m);
D dimetro do conduto (m);
C 1 para conduto enterrado;
coeficiente de Poisson do material de que feito o tubo, adimensional.
1.4.5 Dispositivos de proteo
Segundo Tullis (1989) se as anlises indicarem que o transiente pode causar algum dano,
as solues disponveis aos engenheiros incluem:
1. Aumentar o tempo de abertura e fechamento de vlvulas de controle;
2. Projetar instalaes especiais para encher, fluir e remover ar das tubulaes;
3. Aumentar a classe de presso do conduto;
4. Limitar a velocidade na tubulao;
5. Reduzir a velocidade de propagao da onda alterando o material da tubulao ou
injetando ar;
6. Usar vlvulas de alvio, tanques de surto, cmaras de ar, etc.
Para Koelle (2003) na medida do possvel o engenheiro gostaria de projetar um
equipamento de controle que onde os efeitos transitrios so prevenidos. Utilizando um modelo
computacional, o engenheiro pode experimentar diferentes tempos de operao de vlvulas,
dimetros das tubulaes e controle de bombas, para verificar se os efeitos dos transitrios
podem atingir nveis aceitveis. Caso negativo, equipamentos especficos podem ser
necessrios. Algumas das seguintes medidas podem ser ajustadas e/ou implementadas:
1. Controle de presses mnimas:
a. Volantes de Inrcia;
a. Vlvulas de alivio;
b. Reservatrio de ar comprimido;
c. Tanque unidirecional;
c. Reservatrio hidropneumtico;
d. Vlvulas de ar (ventosas);
d. Reservatrio de ar comprimido;
47
48
k) Vlvula de ar (ventosa)
O acmulo de ar nas adutoras, pode ser causado pelo ar carreado no enchimento e
drenagem das linhas, pela liberao de ar dissolvido na gua em razo da variao de
temperatura e presso e devido a vaporizao da gua. Reservatrios, vlvulas, bombas e juntas
constituem tambm, pontos de introduo de ar, caso no sejam suficientemente estanques.
O ar arrastado e/ou liberado nos pontos elevados do perfil da rede, onde h queda de
presso. A existncia de ar confinado nestes pontos, bolsas de ar, reduz a seo til da
tubulao, podendo causar paralizao no escoamento, devendo ento ser extradas. Quando se
d a remoo hidrulica (arraste pelo escoamento) do ar no interior da tubulao, aumenta o
risco de colapso da bolsa, causando uma regio de sobre presso, que pode ser mais alto que o
PMS da canalizao (adaptado de TSUTIYA, 2006).
Netto (1998) explica que durante o enchimento da tubulao, o volume de gua cresce
lentamente e o ar escapa pelo orifcio, com um volume equivalente quantidade de gua que
entra na tubulao. Durante o esvaziamento ou ocorrncia de depresso na tubulao, o
flutuador desce sob ao do prprio peso, liberando a entrada de ar, pelo orifcio maior, evitando
assim o aparecimento de sub-presses internas que podem causar colapso nas tubulaes.
FIGURA 17 - VENTOSA DE DUPLA FUNO.
KSB (2007) diz que este equipamento no deve ser utilizado at que as outras solues
sejam descartadas e apresenta as seguintes desvantagens:
Requerer manuteno regularmente;
Se instalada no local errado ou montada inadequadamente, elas podem agravar as
variaes de presso ao invs de aliviar.
Para seleo do tamanho da ventosa a ser instalada na linha, deve-se conhecer a vazo
de servio e adotar o valor de 3,5 mca, segundo catlogo Saint-Gobain Canalizaes de 2013,
como o diferencial de presso entre o interior da ventosa e atmosfera no momento de
enchimento ou esvaziamento da linha. Plotando os dados no grfico abaixo, obtm-se o
dimetro da ventosa.
49
Boulos et al (2005) diz que estas vlvulas so instaladas nos pontos altos da canalizao
para prevenir baixas presses (cavitao) emitindo ar, para dentro da tubulao, quando a
presso interna cai abaixo da presso atmosfrica. O ar ento expelido quando a presso
excede a presso atmosfrica. Vlvulas de dois estgios (dupla funo) liberam o ar por um
pequeno orifcio para prevenir a sada abrupta que ocorre quando as veias liquidas se juntam.
l) Reservatrio hidropneumtico (RHO)
Este equipamento possui uma bexiga que separa os dois fluidos (ar comprimido e gua)
o que o diferencia dos antigos reservatrios de ar comprimido (Air vessel, no ingls). A presso
carregada at um valor determinado para que mantenha o volume de ar em condies
operacionais normais (BOULOS et al, 2005, traduo nossa).
O reservatrio hidropneumtico, tambm conhecido como vaso de presso, protege as
instalaes contra sobrepresses e subpresses, impedindo assim a descontinuidade do
escoamento quando o sistema de bombeamento desligado ou quando ocorre um fechamento
rpido de vlvula de bloqueio. Caracteriza-se por ser um tanque metlico de formato cilndrico,
fechado hermeticamente, instalado diretamente na tubulao principal ou numa derivao,
tendo em seu interior gua e ar comprimido (SOUZA, 2008).
50
51
52
Captulo 2
2
METODOLOGIA
Para elaborao deste trabalho supe-se um sistema elevatrio simples, constitudo por
dois reservatrios ligados atravs de um conduto forado em que a bomba se encontra instalada
em uma estao de tratamento de gua (reservatrio de montante) e recalca gua para um
reservatrio apoiado (jusante). Sistema localizado na cidade de Cuiab, Mato Groso.
A figura 21 apresenta as etapas e softwares utilizados na elaborao deste trabalho. Os
mesmos sero descritos em maiores detalhes a seguir.
FIGURA 21 - FLUXOGRAMA PARA OBTENO DOS RESULTADOS.
53
2.1
REA DE ESTUDO
Cuiab a capital do estado de Mato Grosso, localizada nas coordenadas 15 35 45 S,
A estao de tratamento de gua, ETA Ribeiro do Lipa, est localizada em uma rea
de expanso urbana, na Avenida Antrtica, bairro Sucuri, na regio oeste da cidade com as
coordenadas UTM 593410.73 m E, 8277629.58 m S. Faz parte do subsistema de abastecimento
de gua Ribeiro do Lipa, ver figura 25.
A figura 23 apresenta a planta de tratamento de gua, constituda de sistema
convencional de tratamento. A gua armazena um RAP com aproximadamente 25 metros de
dimetro e 4 metros de altura, seguido de duas elevatrias de gua (EEAT).
FIGURA 23 - ETA RIBEIRO DO LIPA (RAP MONTANTE).
54
A figura abaixo apresenta a localizao da ETA, RAP de jusante e a rea por onde ser
traado a linha de recalque, de modo a escolher o caminho mais curto entre reservatrios,
seguindo recomendaes expostas no captulo anterior.
FIGURA 25 - REA DE ESTUDO.
RAP
ETA
55
2.2
TOPOGRAFIA
Inicialmente foi feito o download de duas cenas da misso SRTM, com resoluo
Servio administrado pela USGS (U.S Geological Survey), que o servio geolgico dos Estados Unidos, no site
http://earthexplorer.usgs.gov/.
3
Software livre de Sistema de informaes geogrficas (SIG), licenciado sob a GNU General Public License (Licena
Pblica Geral) e disponibilizado por OSGeo-The Open Source Geospatial Foundation.
56
2.3
POPULAO ATENDIDA
Baseando-se na figura 28, onde a rea em destaque mostra os bairros abastecidos pela
ETA Ribeiro do Lipa (Subsistema de Abastecimento de gua ETA Ribeiro do Lipa), adotouse que o reservatrio de montante abastea, por gravidade, parte dos bairros inumerados abaixo.
Para delimitao da regio a ser abastecida, fora feito a interpretao das isolinhas
geradas no item 3.2 junto a hidrografia da regio. Na obteno da rea parcial atendida pelo
RAP, utilizou-se o complemento CalcArea, disponvel na biblioteca de complementos do
software, delimitando um polgono por bairro, excluindo reas no ocupadas.
A populao fora estimada utilizando mapa de densidade demogrfica por bairro,
elaborado pela Secretaria municipal de desenvolvimento urbano, que utilizou a base de dados
do censo demogrfico 2010 do IBGE, figura 29.
Os bairros atendidos pela ETA Ribeiro do Lipa, mostrados nas figuras 25 e 26 esto
elencados abaixo:
02 Ribeiro do Lipa
06 Despraiado
03 Novo Colorado
25 Jd. Florianpolis
04 Jardim Mariana
26 Jardim Vitria
05 Santa Marta
34 Paiagus
57
2.4
CANALIZAO DE RECALQUE
O traado buscou atender os requisitos mencionados no item 2.1.1. Adotou-se um n a
cada 100 metros de tubulao e nas mudanas bruscas de direo. Para obteno do perfil de
elevao do conduto, realizou-se a interseco e interpolao entre os ns e isolinhas.
58
VERIFICAO DE TRANSIENTE
Inicialmente foi realizada a anlise preliminar de forma expedita, calculando-se a
59
60
Captulo 3
3
RESULTADOS E DISCUSSES
Neste item apresentado os resultados obtidos do processamento digital de informaes,
para delimitao da regio a ser abastecida, assim como a estimativa da populao atendida.
Seguindo para o pr-dimensionamento econmico do conduto de recalque, seleo de bomba e
verificao expedita de transiente hidrulico.
3.1
supra a demanda dos bairros Jardim Florianpolis (25), Paiagus (34) e Despraiado (06), ou
seja, toda ou parcialmente a regio a direita do crrego Ribeiro do Lipa, entre os Crregos do
Ba e Quarta Feira, apresentados na figura 32, a rea considerada de cada bairro representada
pelo polgono vermelho, ver figura 33.
FIGURA 32 - REA ATENDIDA PELA ETA RIBEIRO DO LIPA.
61
62
= 1,2
= 150 L/hab.dia
= 37.115 hab
Encontramos uma vazo de demanda igual a Q = 77,32 L/s = 278,36 m/h = 0,08 m/s
3.2
D (m)
e (mm)
A (m)
V (m/s)
J (m/m)
PMS (mca)
0,9
0,25
250,26
250
0,28
278,07
300
274
5,50
0,05
1,42
0,01138
530,25
326
5,70
0,08
0,99
0,00468
469,07
1,1
0,31
305,88
300
326
5,70
0,08
0,99
0,00468
469,07
1,2
0,33
333,68
350
378
5,90
0,11
0,73
0,00221
418,08
1,3
0,36
361,49
400
429
6,30
0,14
0,57
0,00115
367,10
63
O traado selecionado possui um caminhamento de 5.665,00 metros, que atravessa quatro bairros, sendo eles, Ribeiro da Ponte, Jardim
Mariana, Santa Marta e Despraiado, respectivamente. Apresenta desnvel geomtrico, entre a Estao de tratamento e Reservatrio, de
aproximadamente 40 (quarenta) metros. O perfil da canalizao apresentado no grfico a seguir, junto das linhas hidrulicas dos dimetros
encontrados no passo anterior.
64
DN-300
DN-350
DN-400
240
DN-300
230
DN-350
ELEVAO (m)
220
DN-400
210
204,73
200
190
180
170
164,70
160
150
100
606
1.106
1.537
2.029
2.451
2.993
DISTNCIA (m)
3.665
4.157
4.657
5.110
5.665
65
DN (mm)
J (m/m)
HF
HM calculada
HM adotada
H inicial
40
250
0,008887
50,35
90,38 mca
95 mca
259 m
209 m
4m
40
300
0,003714
21,04
61,07 mca
65 mca
229 m
208 m
4m
40
350
0,001773
10,04
50,07 mca
55 mca
220 m
210 m
5m
40
400
0,000948
5,37
45,40 mca
50 mca
215 m
209 m
5m
H final NA disponvel
Onde: DN: dimetro nominal; J: perda de carga unitria, calculada por Hazen-Willians;
HF: perda de carga total; HM: altura manomtrica; H: elevao e NA: nvel de gua disponvel
no reservatrio de jusante (RAP Bom Clima).
Com base nestes dados e anlise das linhas piezomtricas, adotou-se para o dimetro da
canalizao o DN 400 mm, que apresenta, consideravelmente, menor perda de carga que os
demais dimetros, requerendo, menor potncia do conjunto elevatrio, consequentemente
menor consumo de energia.
A bomba selecionada para suprir esta demanda e presso foi a seguinte:
mca
m/h
66
3.3
DN-400
Sobrepresso
Subpresso
290
270
Sobrepresso
ELEVAO (m)
250
230
210
190
Subpresso
170
150
100
606
1.106
1.537
2.029
2.451
2.993
3.665
4.157
4.657
5.110
5.665
DISTNCIA (m)
Pela anlise do grfico acima o principal problema a subpresso que pode gerar vcuo
em trechos do recalque, com consequente separao de colunas liquidas e aumenta os riscos do
golpe de arete. A sobrepresso mxima suportada pela classe da tubulao escolhida, ou seja,
fica abaixo da presso mxima de servio (PMS) igual a 367 mca.
67
Dados de entrada:
1. Elevao dos ns e dados bsicos dos reservatrios;
68
69
5618,18
5477,73
5337,27
5196,82
5056,36
4915,91
Subpresso
4775,45
4635,00
4494,55
4354,09
4213,64
Sobrepresso
4073,18
3932,73
3792,27
3651,82
3511,36
3370,91
Permanente
3230,45
3090,00
2949,55
2809,09
2668,64
2528,18
Cavitao
2387,73
2247,27
2106,82
1966,36
1825,91
Elevao
1685,45
1545,00
1404,55
1264,09
1123,64
983,18
842,73
702,27
561,82
421,36
280,91
140,45
0,00
310
310,00
ELEVAO (m)
Sobrepresso; 293,37
290
290,00
270
270,00
250
250,00
230
230,00
Permanente; 215,99
208,07
210
210,00
190
190,00
Subpresso; 166,54
170
170,00
150
150,00
0
506
1.006
1.437
1.968
2.382
2.863
DISTNCIA (m)
3.565
4.057
4.557
5.000
5.646
70
CONSIDERAES FINAIS
Este trabalho foi desenvolvido utilizando diversos softwares e servios online, gratuitos
o que possibilita a reproduo na ntegra deste trabalho e a anlise de outras situaes e
sistemas. A adoo do traado da linha de recalque foi feita aleatoriamente, buscando a menor
distncia entre os reservatrios.
No foi objetivo deste trabalho o estudo aprofundado do dimensionamento hidrulico
da linha de recalque, o que deve levar em considerao diversas condies operacionais,
inclusive a metodologia de execuo da obra, assim tambm no fora levada em considerao
valores monetrios.
Pretende-se que este texto seja de utilidade prtica para quem, por interesse natural ou
por simples necessidade, procure informao introdutria sobre aplicao de tcnicas de
sistema de informao geogrfica e utilizao do software QGIS, para aplicao em sistemas
de distribuio de gua, assim como da utilizao do software ALLIEVI e anlises de transiente
hidrulico em condutos forados. Espera-se que este documento venha a representar motivar
profissionais da rea para que seja dada continuidade ao desenvolvimento de trabalhos sobre o
tema.
Seria particularmente interessante a continuao deste trabalho no estudo e seleo do
sistema de proteo ideal para o sistema. Em anlise das caractersticas do perfil da adutora e
de seu traado observa-se que no h condies adequadas para instalao de protees
localizadas ao longo da adutora, como, RUDs Reservatrios Unidirecionais. O perfil irregular
indica a necessidade de se instalar na estao de elevatria um vaso de presso com ar
comprimido (RHO Reservatrio Hidropneumtico), com volume de ar adequado para
controlar a depresso transitria e amortecer as oscilaes de presso.
71
REFERNCIAS
ABNT. NBR 12215/1991 Projeto de Adutora de gua para Abastecimento Pblico, 1991.
ALLIEVI. Manual Tcnico. ITA Universidad Politcnica de Valencia, 2010.
A.R.I. FLOW CONTROL ACCESSORIES Ltd. Catalogo de produtos, disponvel em
www.arivalves.com.
AZEVEDO NETTO, J. M., et al. Manual de Hidrulica. 8 edio. Editora Edgard Blcher.
So Paulo, 1998.
BOULOS, P. F. et al. Hydraulic Transient Guidelines for Protecting Water
Distribution Systems. Peer-Reviewed. 97:5. Journal AWWA. May 2005.
DACACH, N. G. Sistemas Urbanos de gua. 2 Edio. Rio de Janeiro: LTC, 1979.
FILHO, Carlos Fernandes de Medeiros. Abastecimento de gua. Universidade Federal de
Campina Grande Paraba. 2009.
FREIRE, Paula Kristhina Cordeiro. Estudo comparativo entre metodologias de
dimensionamento econmico de adutoras. Dissertao (Mestrado) Universidade Federal da
Paraba. 2000.
HOUGHTALEN, R. J. et al. Engenharia Hidrulica. 4 Edio. Editora Pearson. 2012.
HYDROSTEC. Manual de montagem, operao e manuteno - Reservatrio Antigolpe
de Arete com Bexiga (Hydramer). 2013.
JUNIOR, P. Anlise de transientes hidrulicos em uma adutora utilizando o mtodo das
caractersticas. Trabalho de concluso de curso. Universidade Federal de Santa Catarina. 2008.
KOELLE, E. Transients in Hydraulic Systems. Advanced Water Distribution Modeling and
Management. First Edition. Haestad Methods, 2003.
KSB Bombas Hidrulicas S/A. KSB know-how - Water Hammer. Volume 1. 2007.
72
73